Plastics — Determination of flexural properties

ISO 178:2010 specifies a method for determining the flexural properties of rigid and semi-rigid plastics under defined conditions. A standard test specimen is defined, but parameters are included for alternative specimen sizes for use where appropriate. A range of test speeds is included. The method is used to investigate the flexural behaviour of the test specimens and to determine the flexural strength, flexural modulus and other aspects of the flexural stress/strain relationship under the conditions defined. It applies to a freely supported beam, loaded at midspan (three-point loading test). The method is suitable for use with the following range of materials: thermoplastic moulding, extrusion and casting materials, including filled and reinforced compounds in addition to unfilled types; rigid thermoplastics sheets; thermosetting moulding materials, including filled and reinforced compounds; thermosetting sheets. ISO 178:2010 applies to fibre-reinforced compounds with fibre lengths less than or equal to 7,5 mm prior to processing. For long-fibre-reinforced materials (laminates) with fibre lengths greater than 7,5 mm, see ISO 14125. The method is not normally suitable for use with rigid cellular materials or sandwich structures containing cellular material. In such cases, ISO 1209‑1 and/or ISO 1209‑2 can be used. Contrary to the previous editions of this International Standard, this edition specifies two methods, method A and method B. Method A is identical to the method in previous editions of this International Standard, i.e. it uses a strain rate of 1 %/min throughout the test. Method B uses two different strain rates: 1 %/min for the determination of the flexural modulus and 5 %/min or 50 %/min, depending on the ductility of the material, for the determination of the remainder of the flexural stress-strain curve.

Plastiques — Détermination des propriétés en flexion

L'ISO 178:2010 spécifie une méthode pour la détermination des propriétés en flexion des plastiques rigides et semi-rigides dans des conditions définies. Une éprouvette normalisée est définie, mais des paramètres sont inclus pour d'autres dimensions d'éprouvettes lorsque l'usage est approprié. Une gamme de vitesses d'essai est incluse. La méthode est utilisée pour l'étude du comportement en flexion des éprouvettes et pour la détermination de la résistance en flexion, du module en flexion et d'autres aspects des relations entre la contrainte et la déformation en flexion dans les conditions définies. Elle s'applique à une poutre supportée sans contrainte, chargée au milieu de sa portée (essai de chargement en trois points). La méthode est adaptée à la gamme de matériaux suivants: matériaux thermoplastiques pour moulage, extrusion et coulée, y compris les compositions chargées et renforcées en plus des types non chargés; feuilles thermoplastiques rigides; matériaux thermodurcissables pour moulage, y compris les compositions chargées et renforcées; feuilles thermodurcissables. L'ISO 178:2010 s'applique aux compositions renforcées avec des fibres dont les longueurs avant mise en œuvre sont inférieures ou égales à 7,5 mm. Pour les matériaux renforcés de fibres longues (stratifiés) avec des longueurs de fibres supérieures à 7,5 mm, voir l'ISO 14125. La méthode n'est normalement pas adaptée à l'utilisation de matériaux alvéolaires rigides et de structures sandwichs contenant des matériaux alvéolaires. Dans ces cas, l'ISO 1209-1 et/ou l'ISO 1209-2 peuvent être utilisées. Contrairement aux éditions précédentes de la présente Norme internationale, la présente édition spécifie deux méthodes, la méthode A et la méthode B. La méthode A est identique à la méthode des éditions précédentes de la présente Norme internationale, c'est-à-dire qu'elle utilise un taux de déformation de 1 %/min durant tout l'essai. La méthode B utilise deux taux de déformation différents, 1 %/min pour la détermination du module en flexion et 5 %/min ou 50 %/min, en fonction de la ductilité du matériau, pour la détermination du reste de la courbe contrainte en flexion-déformation.

General Information

Status
Withdrawn
Publication Date
05-Dec-2010
Withdrawal Date
05-Dec-2010
Current Stage
9599 - Withdrawal of International Standard
Start Date
01-Apr-2019
Completion Date
01-Apr-2019
Ref Project

RELATIONS

Buy Standard

Standard
ISO 178:2010 - Plastics -- Determination of flexural properties
English language
19 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 178:2010 - Plastiques -- Détermination des propriétés en flexion
French language
20 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (sample)

INTERNATIONAL ISO
STANDARD 178
Fifth edition
2010-12-15
Plastics — Determination of flexural
properties
Plastiques — Détermination des propriétés en flexion
Reference number
ISO 178:2010(E)
ISO 2010
---------------------- Page: 1 ----------------------
ISO 178:2010(E)
PDF disclaimer

This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but

shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In

downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat

accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.

Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation

parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In

the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.

COPYRIGHT PROTECTED DOCUMENT
© ISO 2010

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,

electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or

ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2010 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 178:2010(E)
Contents Page

Foreword ............................................................................................................................................................iv

1 Scope......................................................................................................................................................1

2 Normative references............................................................................................................................2

3 Terms and definitions ...........................................................................................................................2

4 Principle .................................................................................................................................................5

5 Test machine..........................................................................................................................................5

5.1 General ...................................................................................................................................................5

5.2 Test speed..............................................................................................................................................5

5.3 Supports and loading edge ..................................................................................................................6

5.4 Force- and deflection-measuring systems .........................................................................................6

5.5 Equipment for measuring the width and thickness of the test specimens.....................................7

6 Test specimens......................................................................................................................................8

6.1 Shape and dimensions .........................................................................................................................8

6.2 Anisotropic materials............................................................................................................................9

6.3 Preparation of test specimens .............................................................................................................9

6.4 Specimen inspection...........................................................................................................................10

6.5 Number of test specimens..................................................................................................................10

7 Atmosphere for conditioning and testing.........................................................................................10

8 Procedure.............................................................................................................................................10

9 Calculation and expression of results ..............................................................................................13

9.1 Flexural stress .....................................................................................................................................13

9.2 Flexural strain ......................................................................................................................................13

9.3 Flexural modulus.................................................................................................................................14

9.4 Statistical parameters .........................................................................................................................14

9.5 Significant figures ...............................................................................................................................14

10 Precision ..............................................................................................................................................15

11 Test report............................................................................................................................................15

Annex A (informative) Precision statement....................................................................................................16

Annex B (informative) Influence of changes in test speed on the measured values of flexural

properties .............................................................................................................................................18

Bibliography......................................................................................................................................................19

© ISO 2010 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 178:2010(E)
Foreword

ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies

(ISO member bodies). The work of preparing International Standards is normally carried out through ISO

technical committees. Each member body interested in a subject for which a technical committee has been

established has the right to be represented on that committee. International organizations, governmental and

non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the

International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.

International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.

The main task of technical committees is to prepare International Standards. Draft International Standards

adopted by the technical committees are circulated to the member bodies for voting. Publication as an

International Standard requires approval by at least 75 % of the member bodies casting a vote.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent

rights. ISO shall not be held responsible for identifying any or all such patent rights.

ISO 178 was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 2, Mechanical

properties.

This fifth edition cancels and replaces the fourth edition (ISO 178:2001), which has been technically revised to

[2]

harmonize it with ISO 527-2 with respect to the test speeds used for the determination of the flexural

modulus and for the determination of other flexural properties. This has been done by specifying two methods,

method A and method B. Method A is identical to the method specified in previous editions of ISO 178, i.e. it

uses the same strain rate throughout the test, whereas method B uses two different strain rates (see 1.8 for

details).
It also incorporates the Amendment ISO 178:2001/Amd.1:2004.
iv © ISO 2010 – All rights reserved
---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD ISO 178:2010(E)
Plastics — Determination of flexural properties
1 Scope

1.1 This International Standard specifies a method for determining the flexural properties of rigid (see 3.12)

and semi-rigid plastics under defined conditions. A standard test specimen is defined, but parameters are

included for alternative specimen sizes for use where appropriate. A range of test speeds is included.

1.2 The method is used to investigate the flexural behaviour of the test specimens and to determine the

flexural strength, flexural modulus and other aspects of the flexural stress/strain relationship under the

conditions defined. It applies to a freely supported beam, loaded at midspan (three-point loading test).

1.3 The method is suitable for use with the following range of materials:

⎯ thermoplastic moulding, extrusion and casting materials, including filled and reinforced compounds in

addition to unfilled types; rigid thermoplastics sheets;

⎯ thermosetting moulding materials, including filled and reinforced compounds; thermosetting sheets.

[5] [6]

In agreement with ISO 10350-1 and ISO 10350-2 , this International Standard applies to fibre-reinforced

compounds with fibre lengths u 7,5 mm prior to processing. For long-fibre-reinforced materials (laminates)

[7]
with fibre lengths > 7,5 mm, see ISO 14125 .

The method is not normally suitable for use with rigid cellular materials or sandwich structures containing

[3] [4]
cellular material. In such cases, ISO 1209-1 and/or ISO 1209-2 can be used.

NOTE For certain types of textile-fibre-reinforced plastic, a four-point bending test is preferred. This is described in

ISO 14125.

1.4 The method is performed using specimens which may be either moulded to the specified dimensions,

machined from the central section of a standard multipurpose test specimen (see ISO 20753) or machined

from finished or semi-finished products, such as mouldings, laminates, or extruded or cast sheet.

1.5 The method specifies the preferred dimensions for the test specimen. Tests which are carried out on

specimens of different dimensions, or on specimens which are prepared under different conditions, can

produce results which are not comparable. Other factors, such as the test speed and the conditioning of the

specimens, can also influence the results.

NOTE Especially for semi-crystalline polymers, the thickness of the oriented skin layer, which is dependent on the

moulding conditions, also affects the flexural properties.

1.6 The method is not suitable for the determination of design parameters but can be used in materials

testing and as a quality control test.

1.7 For materials exhibiting non-linear stress/strain behaviour, the flexural properties are only nominal. The

equations given have been derived assuming linear elastic behaviour and are valid for deflections of the

specimen that are small compared to its thickness. With the preferred specimen (which measures

80 mm × 10 mm × 4 mm) at the conventional flexural strain of 3,5 % and a span-to-thickness ratio, L/h, of 16,

the deflection is 1,5h. Flexural tests are more appropriate for stiff and brittle materials showing small

deflections at break than for very soft and ductile ones.
© ISO 2010 – All rights reserved 1
---------------------- Page: 5 ----------------------
ISO 178:2010(E)

1.8 Contrary to the previous editions of this International Standard, this edition specifies two methods,

method A and method B. Method A is identical to the method in previous editions of this International

Standard, i.e. it uses a strain rate of 1 %/min throughout the test. Method B uses two different strain rates:

1 %/min for the determination of the flexural modulus and 5 %/min or 50 %/min, depending on the ductility of

the material, for the determination of the remainder of the flexural stress-strain curve.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.
ISO 291, Plastics — Standard atmospheres for conditioning and testing

ISO 293, Plastics — Compression moulding of test specimens of thermoplastic materials

ISO 294-1:1996, Plastics — Injection moulding of test specimens of thermoplastic materials — Part 1: General

principles, and moulding of multipurpose and bar test specimens

ISO 295, Plastics — Compression moulding of test specimens of thermosetting materials

ISO 2602, Statistical interpretation of test results — Estimation of the mean — Confidence interval

ISO 2818, Plastics — Preparation of test specimens by machining

ISO 7500-1, Metallic materials — Verification of static uniaxial testing machines — Part 1:

Tension/compression testing machines — Verification and calibration of the force-measuring system

ISO 9513, Metallic materials — Calibration of extensometers used in uniaxial testing

ISO 10724-1, Plastics — Injection moulding of test specimens of thermosetting powder moulding compounds

(PMCs) — Part 1: General principles, and moulding of multipurpose test specimens
ISO 16012, Plastics — Determination of linear dimensions of test specimens
ISO 20753, Plastics — Test specimens

ISO 23529, Rubber — General procedures for preparing and conditioning test pieces for physical test

methods
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
test speed
rate of relative movement between the specimen supports and the loading edge
NOTE It is expressed in millimetres per minute (mm/min).
3.2
flexural stress
nominal stress at the outer surface of the test specimen at midspan

NOTE It is calculated from the relationship given in 9.1, Equation (5), and is expressed in megapascals (MPa).

2 © ISO 2010 – All rights reserved
---------------------- Page: 6 ----------------------
ISO 178:2010(E)
3.3
flexural stress at break
flexural stress at break of the test specimen (see Figure 1, curves a and b)
NOTE It is expressed in megapascals (MPa).
3.4
flexural strength

maximum flexural stress sustained by the test specimen during a bending test (see Figure 1, curves a and b)

NOTE It is expressed in megapascals (MPa).
3.5
flexural stress at conventional deflection

flexural stress at the conventional deflection, s , defined in 3.7 (see also Figure 1, curve c)

NOTE It is expressed in megapascals (MPa).
3.6
deflection

distance over which the top or bottom surface of the test specimen at midspan deviates from its original

position during flexure
NOTE It is expressed in millimetres (mm).
3.7
conventional deflection
deflection equal to 1,5 times the thickness, h, of the test specimen
NOTE 1 It is expressed in millimetres (mm).

NOTE 2 Using a span, L, of 16h, the conventional deflection corresponds to a flexural strain (see 3.8) of 3,5 %.

3.8
flexural strain

nominal fractional change in length of an element of the outer surface of the test specimen at midspan

NOTE 1 It is expressed as a dimensionless ratio or a percentage (%).

NOTE 2 It is calculated in accordance with the relationships given in 9.2, Equations (6) and (7).

© ISO 2010 – All rights reserved 3
---------------------- Page: 7 ----------------------
ISO 178:2010(E)
Curve a Specimen that breaks before yielding.

Curve b Specimen that gives a maximum and then breaks before the conventional deflection, s .

Curve c Specimen that neither gives a maximum nor breaks before the conventional deflection, s .

Figure 1 — Typical curves of flexural stress, σ , versus flexural strain, ε , and deflection, s

f f
3.9
flexural strain at break
flexural strain at which the test specimen breaks (see Figure 1, curves a and b)
NOTE It is expressed as a dimensionless ratio or a percentage (%).
3.10
flexural strain at flexural strength
flexural strain at maximum flexural stress (see Figure 1, curves a and b)
NOTE It is expressed as a dimensionless ratio or a percentage (%).
3.11
modulus of elasticity in flexure
flexural modulus

ratio of the stress difference, σ − σ , to the corresponding strain difference, ε (= 0,002 5) − ε (= 0,000 5)

f2 f1 f2 f1
[see 9.3, Equation (9)]
NOTE 1 It is expressed in megapascals (MPa).

NOTE 2 The flexural modulus is only an approximate value of Young's modulus of elasticity.

4 © ISO 2010 – All rights reserved
---------------------- Page: 8 ----------------------
ISO 178:2010(E)
3.12
rigid plastic

plastic that has a modulus of elasticity in flexure or, if that is not applicable, then in tension, greater than

700 MPa
[1]
[ISO 472 ]
3.13
span between specimen supports

distance between the points of contact between the test specimen and the test specimen supports (see

Figure 2)
NOTE It is expressed in millimetres (mm).
3.14
flexural strain rate
rate at which the flexural strain (see 3.8) increases during a test
−1 −1
NOTE It is expressed in reciprocal seconds (s ) or percent per second (%⋅s ).
4 Principle

A test specimen of rectangular cross-section, resting on two supports, is deflected by means of a loading edge

acting on the specimen midway between the supports. The test specimen is deflected in this way at a

constant rate at midspan until rupture occurs at the outer surface of the specimen or until a maximum strain of

5 % (see 3.8) is reached, whichever occurs first. During this procedure, the force applied to the specimen and

the resulting deflection of the specimen at midspan are measured.
5 Test machine
5.1 General

The machine shall comply with ISO 7500-1 and ISO 9513 and the requirements given in 5.2 to 5.4.

5.2 Test speed

The test machine shall be capable of maintaining the test speed (see 3.1), as specified in Table 1.

Table 1 — Recommended values of the test speed, v
Test speed, v Tolerance
mm/min %
1 ±20
2 ±20
5 ±20
10 ±20
20 ±10
50 ±10
100 ±10
200 ±10
500 ±10
The lowest speed is used for specimens with thicknesses between 1 mm
and 3,5 mm (see also 8.5).
© ISO 2010 – All rights reserved 5
---------------------- Page: 9 ----------------------
ISO 178:2010(E)
5.3 Supports and loading edge

Two supports and a central loading edge shall be arranged as shown in Figure 2. The supports and the

loading edge shall be parallel to within ±0,2 mm over the width of the test specimen.

The radius, R , of the loading edge and the radius, R , of the supports shall be as follows:

1 2
R = 5,0 mm ± 0,2 mm;
R = 2,0 mm ± 0,2 mm for test specimen thicknesses u 3 mm;
R = 5,0 mm ± 0,2 mm for test specimen thicknesses > 3 mm.
The span, L, shall be adjustable.
Key
1 test specimen h thickness of specimen
F applied force l length of specimen
R radius of loading edge L length of span between supports
R radius of supports
Figure 2 — Position of test specimen at start of test
5.4 Force- and deflection-measuring systems
5.4.1 Force-measuring system

The force-measuring system shall comply with the requirements of class 1 as defined in ISO 7500-1.

5.4.2 Deflection-measuring system

The deflection-measuring system shall comply with the requirements of class 1 as defined in ISO 9513. This

shall be valid over the whole range of deflections to be measured. Non-contact systems may be used

provided they meet the accuracy requirements stated above. The measurement system shall not be

influenced by machine compliance.
6 © ISO 2010 – All rights reserved
---------------------- Page: 10 ----------------------
ISO 178:2010(E)

When determining the flexural modulus, the deflection-measuring system shall be capable of measuring the

change in deflection to an accuracy of 1 % of the relevant value or better, corresponding to ±3,4 µm for a

support span, L, of 64 mm and a specimen thickness, h, of 4,0 mm (see Figure 3). Other support spans and

specimen thicknesses will lead to different requirements for the accuracy of the deflection-measuring system.

Any deflection indicator capable of measuring deflection to the accuracy specified above is suitable.

NOTE The crosshead displacement includes not only the specimen deflection but also the indentation of the loading

edge and the supports into the specimen and deformation of the machine. The last of these is machine-dependent as well

as load-dependent. Results determined on different types of machine are therefore not comparable.

In general, measurement of crosshead displacement is not suitable for modulus determination unless a

compliance correction is applied.
Key
σ flexural stress
ε flexural strain

s corresponding deflection for a specimen thickness of 4 mm and a span between supports of 64 mm

Figure 3 — Accuracy requirements for determination of flexural modulus
5.5 Equipment for measuring the width and thickness of the test specimens
5.5.1 Rigid materials
5.5.1.1 Specimen thickness

Measure the thickness using a micrometer, at points lying within ±2 mm of the centre of the specimen, in

accordance with ISO 16012, but using a micrometer that has an accuracy of ±0,01 mm as opposed to the

accuracy of ±0,02 mm specified in ISO 16012. The presser foot shall have a flat, circular contact face with a

diameter of W 4 mm and the anvil shall have a spherical contact face of radius 50 mm to avoid errors caused

by misalignment with the test piece.
5.5.1.2 Specimen width

Measure the width in accordance with ISO 16012, using a micrometer that has an accuracy of ±0,02 mm as

specified in ISO 16012. The presser foot shall have either a flat contact face which is circular with a diameter

of 1 mm or a rectangular contact face with the side which will be parallel to the specimen thickness direction

1 mm long.
© ISO 2010 – All rights reserved 7
---------------------- Page: 11 ----------------------
ISO 178:2010(E)
5.5.2 Flexible materials
Measure the dimensions of the test specimens in accordance with ISO 23529.
6 Test specimens
6.1 Shape and dimensions
6.1.1 General

The dimensions of the test specimens shall comply with the relevant material standard and, as applicable,

with 6.1.2 or 6.1.3. Otherwise, the type of specimen shall be agreed between the interested parties.

6.1.2 Preferred specimen type
The dimensions, in millimetres, of the preferred test specimen are:
length, l: 80 ± 2
width, b: 10,0 ± 0,2
thickness, h: 4,0 ± 0,2

In any one test specimen, the thickness within the central third of the length shall not deviate by more than

2 % from its mean value. The width shall not deviate from its mean value within this part of the specimen by

more than 3 %. The specimen cross section should preferably be rectangular, with no rounded edges, except

as noted in 6.4.

The preferred specimen may be machined from the central part of a multipurpose test specimen complying

with ISO 20753.
6.1.3 Other test specimens

When it is not possible or desirable to use the preferred test specimen, use a specimen with the dimensions

given in Table 2.

NOTE Certain specifications require that test specimens from sheets of thickness greater than a specified upper limit

be reduced to a standard thickness by machining one face only. In such cases, it is conventional practice to place the test

specimen such that the original surface of the specimen is in contact with the two supports and the force is applied by the

central loading edge to the machined surface of the specimen.
Table 2 — Values of specimen width, b, in relation to thickness, h
Dimensions in millimetres
Nominal Width, b
thickness, h (±0,5)
1 < h u 3 25,0
3 < h u 5 10,0
5 < h u 10 15,0
10 < h u 20 20,0
20 < h u 35 35,0
35 < h u 50 50,0
For materials with very coarse fillers, the minimum width shall be 30 mm.
8 © ISO 2010 – All rights reserved
---------------------- Page: 12 ----------------------
ISO 178:2010(E)
6.2 Anisotropic materials

6.2.1 In the case of materials having flexural properties that depend on direction, the test specimens shall

be chosen so that the flexural stress will be applied in the same manner and direction as would be

experienced in the end-use application, if known. The relationship between the test specimen and the end-

product envisaged will determine the feasibility of using standard test specimens.

NOTE The position or orientation and the dimensions of the test specimens sometimes have a very significant

influence on the test results.

6.2.2 When the material shows a significant difference (> 20 %) in flexural properties in two principal

directions, it shall be tested in these two directions. The orientation of the test specimen relative to the

principal directions shall be recorded (see Figure 4).
Key
L product length direction
W product width direction
Position of specimen Direction of product Direction of force
LN Length
Normal
WN Width
LP Length
Parallel
WP Width

Figure 4 — Position of test specimen in relation to product direction and direction of force

6.3 Preparation of test specimens
6.3.1 From moulding, extrusion and casting compounds

Specimens shall be prepared in accordance with the relevant material specification. When none exists, and

unless otherwise specified, specimens shall be either directly compression-moulded in accordance with

ISO 293 or ISO 295 or injection-moulded in accordance with ISO 294-1 or ISO 10724-1, as appropriate.

© ISO 2010 – All rights reserved 9
---------------------- Page: 13 ----------------------
ISO 178:2010(E)
6.3.2 From sheets

Specimens shall be machined from sheets or from finished or semi-finished products in accordance with

ISO 2818.
6.4 Specimen inspection

The specimens shall be free of twist and preferably have mutually perpendicular surfaces (see, however, the

Note). All surfaces and edges shall be free from sink marks, scratches, pits and flash (see ISO 294-1:1996,

Amendment 2:2005, Annex D).

The specimens shall be checked for conformity with these requirements by visual observation against a

straight edge, carpenter's square or flat plate, and by measuring with micrometer calipers.

Specimens showing measurable or observable departure from one or more of these requirements shall be

rejected or machined to proper size and shape before testing.

NOTE Injection-moulded test specimens usually have draft angles of between 1° and 2° to facilitate demoulding.

Therefore the side faces in injection-moulded specimens will generally not be parallel. In addition, injection-moulded

specimens are never absolutely free of sink marks. Furthermore, due to differences in the cooling history, the thickness at

the centre of the specimen is generally smaller than at the edge.
6.5 Number of test specimens

6.5.1 At least five test specimens shall be tested in each direction of test (see Figure 4). The number of

specimens may be more than five if greater precision of the mean value is required. It is possible to evaluate

this by means of the confidence interval (95 % probability, see ISO 2602).

6.5.2 In the case of directly injection-moulded test specimens, at least five shall be tested.

It is recommended that specimens always be tested oriented in the same way, i.e. with the surface which was

in contact with the cavity plate or that which was in contact with the fixed plate (see ISO 294-1 or ISO 10724-1,

as appropriate) always in contact with the supports, in order to exclude the effects of any asymmetry

generated by the moulding process.

6.5.3 The results from test specimens that rupture outside the central third of their span length shall be

discarded and new test specimens tested in their place.
7 Atmosphere for conditioning and testing

The test specimens shall be conditioned as specified in the standard for the material being tested. In the

absence of this information, select the most appropriate conditions from ISO 291, unless otherwise agreed

upon by the interested parties, e.g. for testing at high or low temperatures. The preferred set of conditions in

ISO 291 is standard atmosphere 23/50, except when the flexural properties of the material are known to be

insensitive to moisture, in which case humidity control is unnecessary.
8 Procedure

8.1 Measure the width, b, of the test specimens to the nearest 0,1 mm and the thickness, h, to the nearest

0,01 mm at the centre of the test specimens (see Note 1 and Figure 5). Calculate the mean thickness, h , for

the set of specimens.

NOTE 1 Injection-moulded test specimens are never exactly flat or rectangular in cross section. Measuring the

thickness at the centre of the specimen gives the smallest value of the thickness.

10 © ISO 2010 – All rights reserved
---------------------- Page: 14 ----------------------
ISO 178:2010(E)

Discard any specimens with a thickness exceeding the tolerance of ±2 % of the mean value and replace them

by other specimens chosen at random.

A thickness difference, Δh, of up to 0,1 mm due to sink marks (see Figure 5) is acceptable. ISO 294-1:1996,

Amendment 2:2005, D.1.2, gives guidance on how to adjust the hold pressure to minimize sink marks in

injection-moulded specimens.
NOTE 2 For the purposes of t
...

NORME ISO
INTERNATIONALE 178
Cinquième édition
2010-12-15
Plastiques — Détermination des
propriétés en flexion
Plastics — Determination of flexural properties
Numéro de référence
ISO 178:2010(F)
ISO 2010
---------------------- Page: 1 ----------------------
ISO 178:2010(F)
PDF – Exonération de responsabilité

Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier

peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence

autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées

acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute

responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.

Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info

du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir

l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,

veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2010

Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous

quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit

de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.

ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2010 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 178:2010(F)
Sommaire Page

Avant-propos .....................................................................................................................................................iv

1 Domaine d'application ..........................................................................................................................1

2 Références normatives.........................................................................................................................2

3 Termes et définitions ............................................................................................................................3

4 Principe ..................................................................................................................................................5

5 Machine d'essai .....................................................................................................................................5

5.1 Généralités .............................................................................................................................................5

5.2 Vitesse d'essai.......................................................................................................................................5

5.3 Supports et poinçon de charge ...........................................................................................................6

5.4 Indicateurs de charge et de flèche ......................................................................................................6

5.5 Dispositifs de mesurage de la largeur et de l'épaisseur des éprouvettes ......................................8

6 Éprouvettes............................................................................................................................................8

6.1 Forme et dimensions ............................................................................................................................8

6.2 Matériaux anisotropes ..........................................................................................................................9

6.3 Préparation des éprouvettes..............................................................................................................10

6.4 Contrôle des éprouvettes ...................................................................................................................11

6.5 Nombre d'éprouvettes ........................................................................................................................11

7 Atmosphère de conditionnement et d'essai.....................................................................................11

8 Mode opératoire...................................................................................................................................11

9 Calcul et expression des résultats ....................................................................................................14

9.1 Contrainte en flexion...........................................................................................................................14

9.2 Déformation en flexion........................................................................................................................15

9.3 Module en flexion ................................................................................................................................15

9.4 Paramètres statistiques......................................................................................................................16

9.5 Chiffres significatifs............................................................................................................................16

10 Fidélité ..................................................................................................................................................16

11 Rapport d'essai....................................................................................................................................16

Annexe A (informative) Déclaration de fidélité ..............................................................................................17

Annexe B (informative) Influence d'un changement de la vitesse d'essai sur les valeurs

mesurées des propriétés en flexion..................................................................................................19

Bibliographie.....................................................................................................................................................20

© ISO 2010 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO 178:2010(F)
Avant-propos

L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de

normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée

aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du

comité technique créé à cet effet. Les organisations internationales, gouvernementales et non

gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec

la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.

Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,

Partie 2.

La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes

internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur

publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres

votants.

L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de

droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne

pas avoir identifié de tels droits de propriété et averti de leur existence.

L'ISO 178 a été élaborée par le comité technique ISO/TC 61, Plastiques, sous-comité SC 2, Propriétés

mécaniques.

Cette cinquième édition annule et remplace la quatrième édition (ISO 178:2001), qui a fait l'objet d'une

[2]

révision technique afin de l'harmoniser avec l'ISO 527-2 quant à l'utilisation de différentes vitesses d'essai

pour la détermination du module en flexion et des autres caractéristiques de flexion. Cela a été réalisé en

spécifiant deux méthodes, la méthode A et la méthode B. La méthode A est identique à la méthode spécifiée

dans les éditions précédentes de l'ISO 178, c'est-à-dire qu'elle utilise le même taux de déformation durant tout

l'essai, alors que la méthode B utilise deux taux de déformation différents (pour plus de détails, voir 1.8).

Elle incorpore également l'Amendement ISO 178:2001/Amd.1:2004.
iv © ISO 2010 – Tous droits réservés
---------------------- Page: 4 ----------------------
NORME INTERNATIONALE ISO 178:2010(F)
Plastiques — Détermination des propriétés en flexion
1 Domaine d'application

1.1 La présente Norme internationale spécifie une méthode pour la détermination des propriétés en flexion

des plastiques rigides (voir 3.12) et semi-rigides dans des conditions définies. Une éprouvette normalisée est

définie, mais des paramètres sont inclus pour d'autres dimensions d'éprouvettes lorsque l'usage est approprié.

Une gamme de vitesses d'essai est incluse.

1.2 La méthode est utilisée pour l'étude du comportement en flexion des éprouvettes et pour la

détermination de la résistance en flexion, du module en flexion et d'autres aspects des relations entre la

contrainte et la déformation en flexion dans les conditions définies. Elle s'applique à une poutre supportée

sans contrainte, chargée au milieu de sa portée (essai de chargement en trois points).

1.3 La méthode est adaptée à la gamme de matériaux suivants:

⎯ matériaux thermoplastiques pour moulage, extrusion et coulée, y compris les compositions chargées et

renforcées en plus des types non chargés; feuilles thermoplastiques rigides;

⎯ matériaux thermodurcissables pour moulage, y compris les compositions chargées et renforcées; feuilles

thermodurcissables.
[5] [6]
et l'ISO 10350-2 , la présente Norme internationale s'applique aux
En accord avec l'ISO 10350-1

compositions renforcées avec des fibres dont les longueurs avant mise en œuvre sont inférieures ou égales à

7,5 mm. Pour les matériaux renforcés de fibres longues (stratifiés) avec des longueurs de fibres supérieures à

[7]
7,5 mm, voir l'ISO 14125 .

La méthode n'est normalement pas adaptée à l'utilisation de matériaux alvéolaires rigides et de structures

[3] [4]

sandwichs contenant des matériaux alvéolaires. Dans ces cas, l'ISO 1209-1 et/ou l'ISO 1209-2 peuvent

être utilisées.

NOTE Pour certains types de plastiques renforcés avec des fibres textiles, un essai de flexion en quatre points est

recommandé. Ce dernier est décrit dans l'ISO 14125.

1.4 La méthode est réalisée à l'aide d'éprouvettes qui peuvent être soit moulées aux dimensions spécifiées,

soit usinées à partir de la partie centrale d'une éprouvette normalisée à usages multiples (voir l'ISO 20753) ou

usinées à partir de produits finis et semi-finis, tels que des pièces moulées, des stratifiés ou des feuilles

extrudées ou coulées.

1.5 La méthode spécifie les dimensions recommandées pour les éprouvettes. Des essais réalisés avec des

éprouvettes de dimensions différentes ou avec des éprouvettes préparées dans d'autres conditions peuvent

donner des résultats qui ne sont pas comparables. D'autres facteurs, tels que la vitesse d'essai et le

conditionnement des éprouvettes, peuvent également influer sur les résultats.

NOTE En fonction des conditions de moulage, pour les polymères semi-cristallins en particulier, l'épaisseur de la

couche (peau) orientée affecte les propriétés en flexion.

1.6 La méthode n'est pas adaptée pour la détermination des paramètres de calcul mais elle peut être

utilisée pour les essais des matériaux et comme un essai dans un contrôle qualité.

1.7 Pour les matériaux à comportement contrainte/déformation non linéaire, les propriétés en flexion ne

sont que nominales. Les équations indiquées ont été définies dans l'hypothèse d'un comportement élastique

© ISO 2010 – Tous droits réservés 1
---------------------- Page: 5 ----------------------
ISO 178:2010(F)

linéaire et sont valables lorsque la flèche de l'éprouvette est petite comparée à l'épaisseur de celle-ci. La

déformation est de 1,5h pour l'éprouvette recommandée (qui mesure 80 mm × 10 mm × 4 mm), à la

déformation en flexion conventionnelle de 3,5 % et pour un rapport portée sur épaisseur, L/h, de 16. Les

essais de flexion sont donc plus adaptés aux matériaux rigides et fragiles qui présentent de faibles

déformations à la rupture que pour des matériaux très souples et ductiles.

1.8 Contrairement aux éditions précédentes de la présente Norme internationale, la présente édition

spécifie deux méthodes, la méthode A et la méthode B. La méthode A est identique à la méthode des éditions

précédentes de la présente Norme internationale, c'est-à-dire qu'elle utilise un taux de déformation de

1 %/min durant tout l'essai. La méthode B utilise deux taux de déformation différents, 1 %/min pour la

détermination du module en flexion et 5 %/min ou 50 %/min, en fonction de la ductilité du matériau, pour la

détermination du reste de la courbe contrainte en flexion-déformation.
2 Références normatives

Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les

références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du

document de référence s'applique (y compris les éventuels amendements).
ISO 291, Plastiques — Atmosphères normales de conditionnement et d'essai

ISO 293, Plastiques — Moulage par compression des éprouvettes en matières thermoplastiques

ISO 294-1:1996, Plastiques — Moulage par injection des éprouvettes de matériaux thermoplastiques —

Partie 1: Principes généraux, et moulage des éprouvettes à usages multiples et des barreaux

ISO 295, Plastiques — Moulage par compression des éprouvettes de matériaux thermodurcissables

ISO 2602, Interprétation statistique de résultats d'essais — Estimation de la moyenne — Intervalle de

confiance
ISO 2818, Plastiques — Préparation des éprouvettes par usinage

ISO 7500-1, Matériaux métalliques — Vérification des machines pour essais statiques uniaxiaux — Partie 1:

Machines d'essai de traction/compression — Vérification et étalonnage du système de mesure de force

ISO 9513, Matériaux métalliques — Étalonnage des extensomètres utilisés lors d'essais uniaxiaux

ISO 10724-1, Plastiques — Moulage par injection d'éprouvettes en compositions de poudre à mouler (PMC)

thermodurcissables — Partie 1: Principes généraux et moulage d'éprouvettes à usages multiples

ISO 16012, Plastiques — Détermination des dimensions linéaires des éprouvettes
ISO 20753, Plastiques — Éprouvettes

ISO 23529, Caoutchouc — Procédures générales pour la préparation et le conditionnement des éprouvettes

pour les méthodes d'essais physiques
2 © ISO 2010 – Tous droits réservés
---------------------- Page: 6 ----------------------
ISO 178:2010(F)
3 Termes et définitions

Pour les besoins du présent document, les termes et définitions suivants s'appliquent.

3.1
vitesse d'essai
vitesse de déplacement relatif entre les supports et le poinçon de charge
NOTE Elle est exprimée en millimètres par minute (mm/min).
3.2
contrainte en flexion
contrainte nominale de la surface externe de l'éprouvette au milieu de la portée

NOTE Elle est calculée à partir de la relation donnée en 9.1, Équation (5) et est exprimée en mégapascals (MPa).

3.3
contrainte en flexion à la rupture

contrainte en flexion à la rupture de l'éprouvette (voir Figure 1, courbes a et b)

NOTE Elle est exprimée en mégapascals (MPa).
3.4
résistance à la flexion

contrainte maximale en flexion supportée par l'éprouvette durant un essai de flexion (voir Figure 1, courbes a

et b)
NOTE Elle est exprimée en mégapascals (MPa).
3.5
contrainte en flexion à la flèche conventionnelle

contrainte à la flèche conventionnelle, s , définie en 3.7 (voir également Figure 1, courbe c)

NOTE Elle est exprimée en mégapascals (MPa).
3.6
flèche

distance parcourue durant la flexion, à partir de la position initiale, par la surface inférieure ou supérieure de

l'éprouvette au milieu de la portée
NOTE Elle est exprimée en millimètres (mm).
3.7
flèche conventionnelle
flèche égale à 1,5 fois l'épaisseur, h, de l'éprouvette
NOTE 1 Elle est exprimée en millimètres (mm).

NOTE 2 En utilisant une portée, L, de 16h, la flèche conventionnelle correspond à une déformation en flexion (voir 3.8)

de 3,5 %.
© ISO 2010 – Tous droits réservés 3
---------------------- Page: 7 ----------------------
ISO 178:2010(F)
3.8
déformation en flexion

variation fractionnaire nominale de la longueur d'un élément pris dans la surface externe de l'éprouvette au

milieu de la portée
NOTE 1 Elle est exprimée comme un rapport sans dimension ou en pourcentage (%).

NOTE 2 Elle est calculée à partir de la relation donnée en 9.2, Équations (6) et (7).

Courbe a Éprouvette avec rupture avant le seuil d'écoulement.

Courbe b Éprouvette présentant un maximum puis une rupture avant la flèche conventionnelle, s .

Courbe c Éprouvette ne présentant ni maximum, ni rupture avant la flèche conventionnelle, s .

Figure 1 — Courbes types de la contrainte en flexion, σ , par rapport
à la déformation en flexion, ε , et la flèche, s
3.9
déformation en flexion à la rupture

déformation en flexion à la rupture de l'éprouvette (voir Figure 1, courbes a et b)

NOTE Elle est exprimée comme un rapport sans dimension ou en pourcentage (%).
3.10
déformation en flexion à la résistance en flexion

déformation en flexion à la contrainte maximale en flexion (voir Figure 1, courbes a et b)

NOTE Elle est exprimée comme un rapport sans dimension ou en pourcentage (%).
4 © ISO 2010 – Tous droits réservés
---------------------- Page: 8 ----------------------
ISO 178:2010(F)
3.11
module d'élasticité en flexion
module en flexion

rapport de la différence de contrainte σ − σ à la différence de déformation correspondante

f2 f1
ε (= 0,002 5) − ε (= 0,000 5) [voir 9.3, Équation (9)]
f2 f1
NOTE 1 Il est exprimé en mégapascals (MPa).

NOTE 2 Le module en flexion représente seulement une valeur approximative du module d'élasticité de Young.

3.12
plastique rigide

plastique possédant un module d'élasticité en flexion, ou, à défaut, en traction, supérieur à 700 MPa

[1]
[ISO 472 ]
3.13
portée entre supports

distance entre les points de contact de l'éprouvette avec les supports (voir Figure 2)

NOTE Elle est exprimée en millimètres (mm).
3.14
taux de déformation en flexion
vitesse à laquelle la déformation en flexion (voir 3.8) augmente durant un essai
−1 −1

NOTE Il est exprimé en inverse de secondes (s ) ou en pourcentage par seconde, (%·s ).

4 Principe

Une éprouvette de section transversale rectangulaire, reposant sur deux supports, est soumise à une flexion

au moyen d'un poinçon de charge agissant sur l'éprouvette à mi-chemin entre les supports. L'éprouvette est

soumise à flexion à vitesse constante à mi-portée jusqu'à rupture sur la face externe de l'éprouvette ou

jusqu'à ce que la déformation atteigne une valeur maximale de 5 % (voir 3.8), selon ce qui se produit en

premier. Durant cet essai, la charge appliquée à l'éprouvette et la flèche qui en résulte à mi-portée sont

mesurées.
5 Machine d'essai
5.1 Généralités

La machine doit être conforme à l'ISO 7500-1 et l'ISO 9513 et répondre aux exigences énoncées de 5.2 à 5.4.

5.2 Vitesse d'essai

La machine d'essai doit être capable de maintenir la vitesse d'essai (voir 3.1), comme spécifié dans le

Tableau 1.
© ISO 2010 – Tous droits réservés 5
---------------------- Page: 9 ----------------------
ISO 178:2010(F)
Tableau 1 — Valeurs recommandées pour la vitesse d'essai, v
Vitesse d'essai, v Tolérance
mm/min %
±20
±20
5 ±20
10 ±20
20 ±10
±10
100
±10
200 ±10
500 ±10
La plus petite vitesse est utilisée pour les éprouvettes présentant des
épaisseurs comprises entre 1 mm et 3,5 mm (voir également 8.5).
5.3 Supports et poinçon de charge

Deux supports et un poinçon de charge doivent être disposés comme illustré à la Figure 2. Les supports et le

poinçon de charge doivent être parallèles à ±0,2 mm près sur la largeur de l'éprouvette.

Le rayon, R , du poinçon de charge et le rayon, R , des supports doivent être comme suit:

1 2
R = 5,0 mm ± 0,2 mm;
R = 2,0 mm ± 0,2 mm pour des épaisseurs d'éprouvette u 3 mm;
R = 5,0 mm ± 0,2 mm pour des épaisseurs d'éprouvette > 3 mm.
La portée, L, doit être réglable.
5.4 Indicateurs de charge et de flèche
5.4.1 Indicateur de charge

Le système de mesurage de la charge doit répondre aux exigences de la classe 1, telle que définie dans

l'ISO 7500-1.
5.4.2 Indicateur de flèche

Le système de mesurage de la flèche doit répondre aux exigences de la classe 1, telle que définie dans

l'ISO 9513. Cela doit être valide sur la totalité de la plage de valeurs de flèche à mesurer. Des systèmes sans

contact peuvent être utilisés à condition de satisfaire aux exigences d'exactitude indiquées ci-dessus. Le

système de mesurage ne doit pas être influencé par la complaisance de la machine.

Pour la détermination du module en flexion, l'indicateur de flèche doit être capable de mesurer la variation de

la flèche avec une exactitude de 1 % de la valeur correspondante ou mieux, correspondant à ±3,4 µm, pour

une portée entre supports, L, de 64 mm et une épaisseur d'éprouvette, h, de 4,0 mm (voir Figure 3). D'autres

portées et épaisseurs d'éprouvette conduisent à des exigences différentes relatives à l'exactitude de

l'indicateur de flèche.
6 © ISO 2010 – Tous droits réservés
---------------------- Page: 10 ----------------------
ISO 178:2010(F)

Tout indicateur de flèche capable de mesurer la flèche avec l'exactitude spécifiée ci-dessus convient.

NOTE Le déplacement de la traverse mobile englobe non seulement la flèche de l'éprouvette mais également

l'indentation de la tête du poinçon et des supports dans l'éprouvette ainsi que la déformation de la machine. Cette dernière

dépend de la machine ainsi que de la charge. Les résultats obtenus sur différents types de machines ne sont donc pas

comparables.

En général, le déplacement de la traverse mobile n'est pas adapté pour la détermination du module sauf si

une correction de la complaisance est appliquée.
Légende
1 éprouvette
F force appliquée
R rayon du poinçon de charge
R rayon des supports
h épaisseur de l'éprouvette
l longueur de l'éprouvette
L portée entre supports
Figure 2 — Position de l'éprouvette au départ de l'essai
© ISO 2010 – Tous droits réservés 7
---------------------- Page: 11 ----------------------
ISO 178:2010(F)
Légende
σ contrainte en flexion
ε déformation en flexion

s flexion correspondante pour une éprouvette de 4 mm d'épaisseur et une portée entre supports de 64 mm

Figure 3 — Exigences relatives à l'exactitude pour la détermination du module en flexion

5.5 Dispositifs de mesurage de la largeur et de l'épaisseur des éprouvettes
5.5.1 Matériaux rigides
5.5.1.1 Épaisseur de l'éprouvette

Mesurer l'épaisseur au moyen d'un micromètre, en des points se situant à ±2 mm près du centre de

l'éprouvette, conformément à l'ISO 16012, en utilisant toutefois un micromètre dont l'exactitude est de

±0,01 mm, par opposition à la valeur d'exactitude de ±0,02 mm spécifiée dans l'ISO 16012. Le palpeur doit

posséder une surface de contact plate et circulaire, d'un diamètre W 4 mm et la touche fixe doit avoir une

surface de contact sphérique d'un rayon de 50 mm pour éviter les erreurs par désalignement avec

l'éprouvette.
5.5.1.2 Largeur de l'éprouvette

Mesurer la largeur conformément à l'ISO 16012, au moyen d'un micromètre dont l'exactitude est de ±0,02 mm,

comme spécifié dans l'ISO 16012. Le palpeur doit avoir une surface de contact plate et circulaire, d'un

diamètre de 1 mm, ou une surface de contact rectangulaire dont le côté qui sera parallèle à la largeur de

l'éprouvette mesure 1 mm de long.
5.5.2 Matériaux souples
Mesurer les dimensions des éprouvettes conformément à l'ISO 23529.
6 Éprouvettes
6.1 Forme et dimensions
6.1.1 Généralités

Les dimensions des éprouvettes doivent être conformes à la norme relative au matériau concerné et, s'il y a

lieu, à 6.1.2 ou 6.1.3. Autrement, le type d'éprouvette doit faire l'objet d'un accord entre les parties intéressées.

8 © ISO 2010 – Tous droits réservés
---------------------- Page: 12 ----------------------
ISO 178:2010(F)
6.1.2 Type d'éprouvette recommandé
Les dimensions, en millimètres, de l'éprouvette recommandée sont:
longueur, l: 80 ± 2
largeur, b: 10,0 ± 0,2
épaisseur, h: 4,0 ± 0,2

Quelle que soit l'éprouvette, l'épaisseur de la partie centrale sur un tiers de la longueur ne doit pas varier de

plus de 2 % de sa valeur moyenne. La largeur ne doit pas varier de plus de 3 % de sa valeur moyenne sur

cette partie de l'éprouvette. Il convient que la section transversale de l'éprouvette soit de préférence

rectangulaire, sans bords arrondis, à l'exception de ce qui est noté en 6.4.

L'éprouvette recommandée peut être usinée à partir de la partie centrale d'une éprouvette à usages multiples

conforme à l'ISO 20753.
6.1.3 Autres éprouvettes

Lorsqu'il n'est pas possible ou souhaitable d'utiliser l'éprouvette recommandée, utiliser une éprouvette dont

les dimensions sont données dans le Tableau 2.

NOTE Certaines spécifications exigent que les éprouvettes prélevées dans des feuilles d'épaisseur supérieure à une

limite supérieure spécifiée soient réduites à une épaisseur normalisée par usinage d'une face seulement. Dans ces cas, il

est de pratique courante de placer l'éprouvette de façon que la surface d'origine de l'éprouvette soit en contact avec les

deux supports et que la force soit appliquée par le poinçon de charge central sur la face usinée de l'éprouvette.

Tableau 2 — Valeurs de la largeur, b, en fonction de l'épaisseur, h
Dimensions en millimètres
Largeur, b
Épaisseur nominale, h
(±0,5)
1 < h u 3 25,0
3 < h u 5 10,0
5 < h u 10 15,0
10 < h u 20 20,0
20 < h u 35 35,0
35 < h u 50 50,0
Pour des matériaux avec des charges très grossières, la largeur minimale doit
être de 30 mm.
6.2 Matériaux anisotropes

6.2.1 Dans le cas de matériaux ayant des propriétés en flexion qui dépendent de l'orientation, les

éprouvettes doivent être choisies de façon que la contrainte en flexion soit appliquée de la même manière et

dans la même direction que pour l'application finale, si elle est connue. La relation entre l'éprouvette et le

produit final envisagé permettra de déterminer la faisabilité d'utilisation d'éprouvettes normalisées.

NOTE La position ou l'orientation et les dimensions des éprouvettes ont parfois une influence très significative sur les

résultats d'essai.
© ISO 2010 – Tous droits réservés 9
---------------------- Page: 13 ----------------------
ISO 178:2010(F)

6.2.2 Lorsque le matériau présente une différence significative (> 20 %) des propriétés en flexion dans

deux directions principales, il doit être soumis à essai dans ces deux directions. L'orientation des éprouvettes

par rapport aux directions principales doit être notée (voir Figure 4).
Légende
L direction suivant la longueur du produit
W direction suivant la largeur du produit
Position de l'éprouvette Direction du produit Direction de la force
LN Longueur
Perpendiculaire
WN Largeur
LP Longueur
Parallèle
WP Largeur

Figure 4 — Position de l'éprouvette en fonction de la direction du produit et de la direction de la force

6.3 Préparation des éprouvettes
6.3.1 Compositions pour moulage, extrusion et coulée

Les éprouvettes doivent être préparées conformément à la spécification du matériau concerné. Lorsqu'il

n'existe aucune spécification, et sauf spécification contraire, les éprouvettes doivent être soit directement

moulées par compression conformément à l'ISO 293 ou l'ISO 295 ou moulées par injection conformément à

l'ISO 294-1 ou l'ISO 10724-1, selon le cas.
6.3.2 Feuilles

Les éprouvettes doivent être usinées à partir de feuilles ou de produits finis ou semi-finis conformément à

l'ISO 2818.
10 © ISO 2010 – Tous droits réservés
---------------------- Page: 14 ----------------------
ISO 178:2010(F)
6.4 Contrôle des éprouvettes

Les éprouvettes doivent être exemptes de torsion et de préférence avoir leurs surfaces mutuellement

perpendiculaires (cependant, voir Note). Les surfaces et les bords doivent être exempts de retassures, de

rayures, de creux et de bavures (voir l'ISO 294-1:1996/Amd.2:2005, Annexe D).

La conformité des éprouvettes à ces exigences doit être vérifiée par un examen visuel de la rectitude des

bords, de la perpendicularité et de la planéité et par une mesure avec des comparateurs micrométriques.

Des éprouvettes présentant un écart mesurable ou observable par rapport à l'une ou plusieurs de ces

exigences doivent être éliminées ou usinées aux dimensions et à la forme correctes avant l'essai.

NOTE Les éprouvettes moulées par injection ont habituellement des angles de dépouille compris entre 1° et 2° pour

faciliter le démoulage. Par conséquent, les faces opposées des éprouvettes moulées ne sont généralement pas parallèles.

De plus, les éprouvettes moulées par injection ne sont jamais totalement exem
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.