Clinical laboratory testing and in vitro medical devices - Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy

ISO 17593:2007 specifies requirements for in vitro measuring systems for self-monitoring of vitamin-K antagonist therapy, including performance, quality assurance and user training and procedures for the verification and validation of performance by the intended users under actual and simulated conditions of use. ISO 17593:2007 pertains solely to prothrombin time measuring systems used by individuals for monitoring their own vitamin-K antagonist therapy, and which report results as international normalized ratios (INR). ISO 17593:2007 is applicable to manufacturers of such systems and those other organizations (e.g., regulatory authorities and conformity assessment bodies) having the responsibility for assessing the performance of these systems. ISO 17593:2007 does not pertain to in vitro measuring systems for coagulation quantities assessing vitamin-K antagonist therapy used by physicians or healthcare providers, provide a comprehensive evaluation of all possible factors that could affect the performance of these systems, or address the medical aspects of oral anticoagulation therapy.

Laboratoires d'analyses de biologie médicale et dispositifs médicaux de diagnostic in vitro — Exigences relatives aux systèmes d'autosurveillance des traitements par anti-coagulant oraux

General Information

Status
Withdrawn
Publication Date
16-Apr-2007
Current Stage
9599 - Withdrawal of International Standard
Start Date
11-Mar-2022
Completion Date
13-Dec-2025
Ref Project

Relations

Standard
ISO 17593:2007 - Clinical laboratory testing and in vitro medical devices -- Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy
English language
54 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 17593:2007
Russian language
80 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

ISO 17593:2007 is a standard published by the International Organization for Standardization (ISO). Its full title is "Clinical laboratory testing and in vitro medical devices - Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy". This standard covers: ISO 17593:2007 specifies requirements for in vitro measuring systems for self-monitoring of vitamin-K antagonist therapy, including performance, quality assurance and user training and procedures for the verification and validation of performance by the intended users under actual and simulated conditions of use. ISO 17593:2007 pertains solely to prothrombin time measuring systems used by individuals for monitoring their own vitamin-K antagonist therapy, and which report results as international normalized ratios (INR). ISO 17593:2007 is applicable to manufacturers of such systems and those other organizations (e.g., regulatory authorities and conformity assessment bodies) having the responsibility for assessing the performance of these systems. ISO 17593:2007 does not pertain to in vitro measuring systems for coagulation quantities assessing vitamin-K antagonist therapy used by physicians or healthcare providers, provide a comprehensive evaluation of all possible factors that could affect the performance of these systems, or address the medical aspects of oral anticoagulation therapy.

ISO 17593:2007 specifies requirements for in vitro measuring systems for self-monitoring of vitamin-K antagonist therapy, including performance, quality assurance and user training and procedures for the verification and validation of performance by the intended users under actual and simulated conditions of use. ISO 17593:2007 pertains solely to prothrombin time measuring systems used by individuals for monitoring their own vitamin-K antagonist therapy, and which report results as international normalized ratios (INR). ISO 17593:2007 is applicable to manufacturers of such systems and those other organizations (e.g., regulatory authorities and conformity assessment bodies) having the responsibility for assessing the performance of these systems. ISO 17593:2007 does not pertain to in vitro measuring systems for coagulation quantities assessing vitamin-K antagonist therapy used by physicians or healthcare providers, provide a comprehensive evaluation of all possible factors that could affect the performance of these systems, or address the medical aspects of oral anticoagulation therapy.

ISO 17593:2007 is classified under the following ICS (International Classification for Standards) categories: 11.100.20 - Biological evaluation of medical devices. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 17593:2007 has the following relationships with other standards: It is inter standard links to ISO 17593:2022. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase ISO 17593:2007 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of ISO standards.

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 17593
First edition
2007-04-15
Clinical laboratory testing and in vitro
medical devices β€” Requirements for in
vitro monitoring systems for self-testing
of oral anticoagulant therapy
Laboratoires d'analyses de biologie mΓ©dicale et dispositifs mΓ©dicaux de
diagnostic in vitro — Exigences relatives aux systèmes
d'autosurveillance des traitements par anti-coagulant oraux

Reference number
Β©
ISO 2007
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.

Β© ISO 2007
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 β€’ CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii Β© ISO 2007 – All rights reserved

Contents Page
Foreword. v
Introduction . vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions. 2
4 Design and development . 8
4.1 General requirements. 8
4.2 Measuring interval . 8
4.3 Safety . 8
4.4 Risk management . 8
4.4.1 Acceptability of risks. 8
4.4.2 Risk assessment. 8
4.5 Ergonomic and human factor aspects . 9
4.6 Quality assurance and risk controls. 9
4.6.1 General. 9
4.6.2 Measurement verification . 10
4.6.3 Control of system performance . 10
4.6.4 Verification of self-testing performance. 10
4.6.5 Evaluation of user compliance in following the manufacturer’s and the physician’s
instructions . 10
4.7 Metrological traceability. 10
5 Information supplied by the manufacturer . 11
5.1 General requirements. 11
5.2 Labels for the oral-anticoagulation monitoring instrument . 11
5.3 Instructions for use of the oral-anticoagulation monitoring system . 12
5.4 Labels for the reagents and control material. 13
5.5 Instructions for use for reagents and control material. 13
6 Safety and reliability testing . 14
6.1 General requirements. 14
6.1.1 Protocol . 14
6.1.2 Instruments and reagents. 15
6.1.3 Acceptance criteria. 15
6.2 Protection against electric shock . 15
6.3 Protection against mechanical hazards .15
6.4 Electromagnetic compatibility. 15
6.5 Resistance to heat . 15
6.6 Resistance to moisture and liquids . 15
6.7 Protection against liberated gases, explosion and implosion. 15
6.8 Instrument components. 15
6.9 Performance test. 15
6.10 Mechanical resistance to shock, vibration and impact . 16
6.10.1 Vibration test protocol. 16
6.10.2 Drop test protocol. 16
6.11 Temperature exposure limits. 16
6.11.1 High-temperature test protocol . 16
6.11.2 Low-temperature test protocol. 17
6.12 Humidity-exposure test protocol . 17
6.13 Reagent storage and use testing . 17
7 Training and education programs. 17
7.1 Training of healthcare providers . 17
7.2 Education of patients and other users . 18
8 System performance verification . 19
8.1 General . 19
8.2 Contributors to measurement uncertainty . 19
8.3 System performance verification study. 19
8.4 Verification of measurement precision. 20
8.4.1 General . 20
8.4.2 Verification of measurement repeatability .20
8.4.3 Verification of intermediate measurement precision . 21
8.4.4 Data analysis . 22
8.5 Verification of system accuracy . 24
8.5.1 General requirements . 24
8.5.2 Study population. 24
8.5.3 Samples. 25
8.5.4 Instruments and reagents . 25
8.5.5 Manufacturer’s selected measurement procedure. 26
8.5.6 Study design. 26
8.5.7 Procedure. 27
8.5.8 Data analysis . 28
8.6 Minimum acceptable system accuracy. 31
8.6.1 System accuracy requirement. 31
8.6.2 System accuracy assessment . 31
8.6.3 Data presentation. 32
9 User performance evaluation. 32
9.1 General . 32
9.2 Study sites . 32
9.3 Subjects . 33
9.4 Instruments and materials . 33
9.5 Evaluation of user proficiency. 33
9.6 Acceptance criteria and data assessment . 34
9.7 Evaluation of instructions for use. 34
Annex A (normative) Additional requirements for electromagnetic compatibility. 35
Annex B (informative) Traceability chain examples. 37
Annex C (informative) Sample size calculation to estimate bias ([42] in the Bibliography) . 40
Annex D (informative) Example of an uncertainty calculation for a prothrombin INR determination
using an oral anticoagulation monitoring system. 41
Annex E (informative) Elements of quality assurance of oral-anticoagulation monitoring systems . 45
Annex F (informative) Application of performance criteria to published evaluations of oral-
anticoagulation monitoring systems . 46
Bibliography . 51

iv Β© ISO 2007 – All rights reserved

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 17593 was prepared by Technical Committee ISO/TC 212, Clinical laboratory testing and in vitro
diagnostic test systems.
Introduction
Oral-anticoagulation monitoring systems are in vitro diagnostic medical devices that measure prothrombin
time in fresh, unmodified human blood samples. Prothrombin time is an indicator of the ability of blood to clot.
In vitro diagnostic medical devices for self-testing of oral-anticoagulation therapy are used predominantly by
individuals who have heart valve replacements, or who are suffering from atrial fibrillation or deep vein
thrombosis. Patients must maintain the level of anticoagulant in the blood high enough to reduce thrombin
formation, yet low enough to avoid excessive bleeding. An oral-anticoagulation monitoring system allows the
user to monitor anticoagulation therapy and take action to control the level of anticoagulant present in the
blood.
This International Standard applies to oral-anticoagulation monitoring systems to be used by lay persons. The
primary objectives are to establish requirements for oral-anticoagulation monitoring systems that will enable
lay users to achieve acceptable performance, and to specify procedures for manufacturers and other
interested parties to demonstrate conformance of such systems to this standard.
Performance criteria for oral-anticoagulation monitoring systems were established, based on the state-of-the-
art, which has been shown to offer significant benefit to patients [68], [69]. The criteria are given in terms of
β€œsystem accuracy”, because metrological terms commonly used in International Standards (e.g., trueness and
measurement uncertainty) would not be familiar to lay users. System accuracy, which is affected by
systematic bias and random effects (and is inversely related to measurement uncertainty), describes the
degree to which the individual results produced by an oral-anticoagulation monitoring system agree with
correct INR values when the system is used as intended by lay persons.
In setting the performance criteria, it is assumed that users will be properly selected and will receive the
necessary training, that the device will be properly maintained, and that operating and control procedures will
be followed in accordance with the manufacturer’s instructions for use. It is also assumed that manufacturers
will anticipate and mitigate the effects of reasonably foreseeable misuse, including reasonably foreseeable
deviations from recommended maintenance, operating and control procedures by the intended users.
Requirements that are unique to self-testing with oral-anticoagulation monitoring systems, including specific
content of information supplied by the manufacturer, are addressed in this International Standard. General
requirements that apply to all in vitro diagnostic medical devices and are covered by other standards (e.g.,
IEC 61010, ISO 13485, ISO 14971 and ISO 18113) are incorporated by reference, where appropriate. In
addition, national regulations may apply.

vi Β© ISO 2007 – All rights reserved

INTERNATIONAL STANDARD ISO 17593:2007(E)

Clinical laboratory testing and in vitro medical devices β€”
Requirements for in vitro monitoring systems for self-testing of
oral anticoagulant therapy
1 Scope
This International Standard specifies requirements for in vitro measuring systems for self-monitoring of
vitamin-K antagonist therapy, including performance, quality assurance and user training and procedures for
the verification and validation of performance by the intended users under actual and simulated conditions of
use.
This International Standard pertains solely to prothrombin time measuring systems used by individuals for
monitoring their own vitamin-K antagonist therapy, and which report results as international normalized ratios
(INR).
This International Standard is applicable to manufacturers of such systems and those other organizations (e.g.,
regulatory authorities and conformity assessment bodies) having the responsibility for assessing the
performance of these systems.
This International Standard does not
⎯ pertain to in vitro measuring systems for coagulation quantities assessing vitamin-K antagonist therapy
used by physicians or healthcare providers,
⎯ provide a comprehensive evaluation of all possible factors that could affect the performance of these
systems, or
⎯ address the medical aspects of oral-anticoagulation therapy.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 13485, Medical devices β€” Quality management systems β€” Requirements for regulatory purposes
ISO 14971, Medical devices β€” Application of risk management to medical devices
ISO 15198, Clinical laboratory medicine β€” In vitro diagnostic medical devices β€” Validation of user quality
control procedures by the manufacturer
ISO 17511, In vitro diagnostic medical devices β€” Measurement of quantities in biological samples β€”
Metrological traceability of values assigned to calibrators and control materials
1)
ISO 18113-1:β€” , Clinical laboratory testing and in vitro diagnostic medical systems β€” Information supplied
by the manufacturer (labelling) β€” Part 1: Terms, definitions and general requirements
1)
ISO 18113-4:β€” , Clinical laboratory testing and in vitro diagnostic medical systems β€” Information supplied
by the manufacturer (labelling) β€” Part 4: In vitro diagnostic reagents for self-testing
1)
ISO 18113-5:β€” , Clinical laboratory testing and in vitro diagnostic medical systems β€” Information supplied
by the manufacturer (labelling) β€” Part 5: In vitro diagnostic instruments for self-testing
IEC 60068-2-64:1993, Environmental testing β€” Part 2: Test methods β€” Test Fh: Vibration, broad-band
random (digital control) and guidance
IEC 61010-1:2001, Safety requirements for electrical equipment for measurement, control and laboratory
use β€” Part 1: General requirements
IEC 61010-2-101:2002, Safety requirements for electrical equipment for measurement, control and laboratory
use β€” Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
IEC 61000-4-2, Electromagnetic compatibility (EMC) β€” Part 4-2: Testing and measurement techniques β€”
Electrostatic discharge immunity test
IEC 61000-4-3, Electromagnetic compatibility (EMC) β€” Part 4-3: Testing and measurement techniques β€”
Radiated, radio-frequency, electromagnetic field immunity test
IEC 61326, Electrical equipment for measurement, control and laboratory use β€” EMC requirements
EN 13532:2002, General requirements for in vitro diagnostic medical devices for self-testing
EN 13612, Performance evaluation of in vitro diagnostic medical devices
EN 13640, Stability testing of in vitro diagnostic reagents
WHO Technical Report Series, No. 889, 1999, Annex 3 β€” Guidelines for thromboplastins and plasma used to
control oral-anticoagulant therapy
3 Terms and definitions
For the purposes of this document, the terms and definitions in ISO 18113-1 and the following apply.
3.1
accuracy of measurement
closeness of agreement between a measurement result and the accepted reference value
NOTE 1 The term β€œmeasurement accuracy”, when applied to a set of test results, involves a combination of random
components and a common systematic error or bias component. (VIM:1993)
NOTE 2 For oral-anticoagulation monitoring systems, accuracy is measured by the extent to which measurements of
blood samples from different patients agree with INR values traceable to a thromboplastin International Reference
Preparation (IRP).
NOTE 3 Adapted from ISO 3534-1:2006, 3.11.

1) To be published.
2 Β© ISO 2007 – All rights reserved

3.2
bias of measurement
difference between the expectation of the test results and an accepted reference value
[ISO 5725-1:1994, 3.8]
NOTE Bias is a measure of trueness. [VIM:1993]
3.3
blood
circulating intravascular tissue of the body, consisting of suspended formed elements and fluid plasma and
suspended formed elements
NOTE In this International Standard, the term refers to fresh, nonanticoagulated blood.
3.4
capillary blood sample
blood collected after puncturing minute vessels that connect the arterioles and venules
NOTE Often obtained by pricking a fingertip; capillary blood is usually collected without additives, such as
anticoagulants or preservatives. Therefore, it is inherently unstable.
3.5
control material
substance, material or article intended by the manufacturer to be used to verify the performance
characteristics of an in vitro diagnostic medical device
NOTE 1 Adapted from EN 375:2001, 3.5.
NOTE 2 Control materials for anticoagulation monitoring may be reactive or nonreactive. A reactive control material
participates in a reaction with the reagent components. A nonreactive control does not react with the reagent components,
but may provide control functionality through other means, e.g., a simulation of the reaction (see physical control).
3.6
control interval
statistically justified values specified as acceptable measured values obtained using a given control material
3.7
healthcare provider
individual authorized to deliver health care to a patient
NOTE In this International Standard, a healthcare provider is an individual, such as a doctor, nurse, technician,
technical specialist or appropriate assistant, that provides instruction to a self-testing patient.
3.8
integrated functional control
control material that is inherent in a reagent component of a measuring system, intended by the manufacturer
to verify the performance of the measuring system
NOTE The integrated functional control is run concurrently with a patient measurement, includes a reactive
component and provides a functional check of the measurement procedure. The integrated control results must be within
a predefined measurement interval for the measured value to be displayed.
3.9
international normalized ratio
INR
patient’s prothrombin time measurement result, which has been standardized for the potency of the
thromboplastin used in the measurement procedure and expressed relative to a normal population average
[30]
NOTE For a discussion of the use of INR, see Poller, et al. .
3.10
international reference preparation
IRP
reference calibrator maintained by the World Health Organization
NOTE The IRP for thromboplastin is directly calibrated for potency against the original British comparative
thromboplastin preparations used in the establishment of the INR system.
3.11
intermediate precision of measurement
measurement precision under conditions intermediate between reproducibility conditions and repeatability
conditions
[5]
NOTE 1 The concept of intermediate levels of precision is described in ISO 5725-3:1994 .
NOTE 2 Quantitative measures of intermediate precision depend on the stipulated conditions.
NOTE 3 Intermediate precision provides an indication of the variability that will be experienced by a user during typical
use.
3.12
intermediate precision conditions
conditions where independent measurement results are obtained with the same measurement method on
identical samples in the same location, but where other variables, such as operators, equipment, calibration,
environmental conditions and/or time intervals, differ
3.13
international sensitivity index
ISI
factor that allows the conversion of a patient’s prothrombin time measurement result to international
normalized ratio values
[30]
NOTE For a discussion of the use of ISI and INR, see Poller, et al. .
3.14
lay person
individual without formal training in a relevant field or discipline
NOTE 1 Adapted from the definition of β€œlay user” in EN 376:2002.
NOTE 2 For the purposes of this International Standard, a lay person is a user of an oral-anticoagulation monitoring
device who does not have specific medical, scientific or technical knowledge related to oral-anticoagulation monitoring.
3.15
manufacturer’s working calibrator
working measurement standard
standard that is used routinely at the manufacturer's laboratory to calibrate or check material measures,
measuring instruments or reference materials
NOTE 1 Adapted from ISO 17511:2003.
NOTE 2 This applies to a thromboplastin preparation used by the manufacturer during the preparation of a PT reagent
mixture.
NOTE 3 The assigned value of the manufacturer’s working calibrator is metrologically traceable to that of the IRP.
3.16
manufacturer’s selected measurement procedure
measurement procedure that is calibrated by one or more primary or secondary calibrators and validated for
its intended use
NOTE ISO 17511:2003, 4.2.2 f), shows the manufacturer’s selected measurement procedure in the traceability chain.
4 Β© ISO 2007 – All rights reserved

3.17
manufacturer’s standing measurement procedure
measurement procedure that is calibrated by one or more of the manufacturer’s working calibrators or higher
types of calibrator and validated for its intended use
NOTE ISO 17511:2003, 4.2.2 h) shows the manufacturer’s standing measurement procedure in the traceability chain.
3.18
measurement procedure
set of operations, described specifically, used in the performance of particular measurements according to a
given method
[VIM:1993, 2.5]
3.19
measuring interval
set of values of measurands for which the bias and imprecision are intended to lie within specified limits
NOTE 1 This represents the interval of examination results over which the performance characteristics have been
validated by the manufacturer.
NOTE 2 Adapted from VIM:1993, 5.4.
3.20
metrological traceability
property of the result of a measurement or the value of a standard whereby it can be related to stated
references, usually national or international standards, through an unbroken chain of comparisons all having
stated uncertainties
[VIM:1993, 6.10]
3.21
physical control system
control device that does not include chemically reactive components and that is intended by the manufacturer
to verify the performance of the instrument
NOTE 1 The physical control system may be in the form of an electronic device that provides a simulated reaction.
NOTE 2 The physical control result must be within predefined limits, in order for the measuring system to be
considered properly functional.
3.22
precision of measurement
closeness of agreement between independent measurement results obtained under stipulated conditions
NOTE 1 Adapted from ISO 3534-2:2006.
NOTE 2 The degree of precision is expressed numerically by the statistical measures of imprecision of measurements,
such as standard deviation and coefficient of variation, that are inversely related to precision. Quantitative measures of
precision depend on the stipulated conditions.
NOTE 3 Precision of a given measurement procedure is subdivided according to the specified precision conditions.
Particular sets of extreme conditions are termed β€œrepeatability” (3.26) and β€œreproducibility” (3.28).
3.23
prothrombin time
PT
time required to clot a blood sample once exposed to a thromboplastin reagent material
3.24
prothrombin time measuring system
measuring system that records the time required for a sample to clot after being exposed to a thromboplastin
or tissue-factor derived reagent
NOTE The system includes the reagent plus the instrument used to record the clotting time.
3.25
reagent
part of the in vitro diagnostic medical device that produces a signal via a chemical or electrochemical reaction,
which allows the quantity to be detected and its value measured in a sample
3.26
repeatability of measurement
precision of measurement under repeatability conditions
NOTE Adapted from ISO 3534-2:2006.
3.27
repeatability conditions
conditions where independent measurement results are obtained with the same method of measurement on
identical samples in the same laboratory by the same operator using the same equipment within short
intervals of time
NOTE 1 Adapted from ISO 3534-2:2006.
NOTE 2 Essentially unchanging conditions, intended to represent conditions resulting in minimum variability of
measurement results.
NOTE 3 For the purposes of this International Standard, β€œlaboratories” should be interpreted as β€œlocations”.
3.28
reproducibility of measurement
precision of measurement under reproducibility conditions
NOTE Adapted from ISO 3534-2:2006.
3.29
reproducibility conditions
conditions where measurement results are obtained with the same method of measurement on identical
samples in different laboratories with different operators using different equipment
NOTE 1 Completely changed conditions are intended to represent conditions resulting in maximum variability of test
results.
NOTE 2 For the purposes of this International Standard, β€œlaboratories” should be interpreted as β€œlocations”.
NOTE 3 Adapted from ISO 3534-2:2006.
3.30
secondary reference measurement procedure
measurement procedure that is calibrated by one or more primary calibrators
NOTE The measurement procedure for prothrombin time measurements is sometimes referred to as a β€œsecondary
standard procedure”.
3.31
system accuracy
closeness of agreement of a set of representative measurement results from a measuring system and their
respective reference values
6 Β© ISO 2007 – All rights reserved

NOTE 1 The term accuracy of measurement, when applied to a set of measurement results, involves a combination of
random error components and a common systematic error or bias component.
NOTE 2 Reference values are assigned by a measurement procedure traceable to a reference measurement
procedure of higher order.
NOTE 3 System accuracy may be expressed as the interval that encompasses 95 % of the differences observed
between the results of the system being evaluated and their reference values. This interval also includes measurement
uncertainty from the measurement procedure used to assign the reference values.
NOTE 4 Adapted from ISO 15197:2003, 3.24.
3.32
trueness of measurement
closeness of agreement between the average value obtained from a large series of measurement results and
an accepted reference value
NOTE 1 A measure of trueness is bias (3.2).
NOTE 2 Adapted from ISO 3534-2:2006.
3.33
type test
test of one or more samples of equipment (or parts of equipment) made to a particular design, to show that
the design and construction meet one or more requirements of the applicable standard
NOTE 1 Statistical sampling is not required for a type test.
NOTE 2 Adapted from IEC 61326:2002.
3.34
user compliance
ability and willingness of the user of a measuring system to adhere to and operate within the defined
specifications of a measurement procedure
3.35
venous blood sample
blood collected after directly puncturing a vein, usually with a needle and syringe, or another collection device
NOTE Venous blood may be collected without additives such as anticoagulants or preservatives, and if so, will be
inherently unstable; venous blood may also be collected in containers containing additives or preservatives with the intent
to stabilize specific components.
3.36
volume fraction of erythrocytes in blood
proportion of packed cells in a blood sample
NOTE 1 Expressed either as a fraction, often given as a percentage (conventional) of the SI unit.
NOTE 2 Sometimes referred to as β€œhaematocrit”, after the instrument originally used to estimate the volume fraction of
erythrocytes in blood.
4 Design and development
4.1 General requirements
The requirements specified in ISO 13485 apply.
The requirements specified in EN 13532 apply to evaluation of the performance of the oral-anticoagulation
monitoring system.
NOTE Clauses 6 and 8 describe design verification activities, which are intended to provide assurance that the
product has the capability of meeting precision, trueness, safety and reliability specifications. Clause 9 describes design
validation activities, which are intended to provide assurance that the device meets the user requirements.
4.2 Measuring interval
The measuring interval of the system shall be at least 1,0 to 6,0 INR.
4.3 Safety
The requirements specified in IEC 61010-1 and IEC 61010-2-101 apply.
4.4 Risk management
4.4.1 Acceptability of risks
The manufacturer shall decide upon the acceptability of potential risks from knowledge of factors including,
but not limited to, the following:
a) intended use of the product;
b) users’ skills and limitations:
c) protection against unintentional change of settings (e.g., units reported);
d) likely deviations from recommended maintenance, operating and control procedures;
e) influence of interfering substances.
[25]
NOTE Guidelines for evaluating potentially interfering substances are found in CLSI document EP7 .
4.4.2 Risk assessment
The requirements specified in ISO 14971 apply.
In performing risk assessment, the manufacturer shall consider
a) severity of the consequences of an undetected failure (e.g., potential harm to the patient),
b) probability of occurrence of a mistake (e.g., insufficient sample volume or incorrect reagent unit
placement), and
c) probability of the system failing to detect the mistake (e.g., deficient internal instrument sensors).
NOTE 1 This International Standard does not specify levels of risk acceptability.
NOTE 2 Guidelines for identifying potential hazards from the use of β€œunit use devices” are found in CLSI document
[27]
EP18 .
NOTE 3 Risk management includes risk analysis, risk evaluation, risk reduction and risk control.
8 Β© ISO 2007 – All rights reserved

4.5 Ergonomic and human factor aspects
The design of the oral-anticoagulation monitoring system shall take into consideration relevant ergonomic and
human factors including, but not limited to, the following.
a) User aspects:
⎯ selection;
⎯ training;
⎯ compliance.
b) Use environment:
⎯ temperature;
⎯ humidity.
c) System properties:
⎯ shock resistance;
⎯ stability of reagents.
d) User interface:
⎯ ease of operation;
⎯ ease of maintenance;
⎯ protection from typical β€œwear and tear” that might be encountered in the use environment;
⎯ readability of reported results;
⎯ fault conditions and error messages;
⎯ unambiguous messages to the user (e.g., β€œlow battery” or β€œlow result”) rather than only β€œlow”;
⎯ user verification of proper system function.
4.6 Quality assurance and risk controls
4.6.1 General
Quality assurance of oral anticoagulation monitoring systems consists of multiple elements. See Annex E for
descriptions of the various elements of quality assurance that may apply.
The manufacturer shall provide device-specific risk control measures, as required by the risk management
plan. The requirements specified in ISO 14971 apply.
The risk control measures, including any limitations, shall be described in the instructions for use and the
training program as appropriate.
Risk control measures shall address the education and training of users and healthcare providers (see
Clause 7), as well as the following elements.
4.6.2 Measurement verification
Each measurement reported by the oral-anticoagulation monitoring system shall be verified internally by the
measuring system.
The nature and extent of internal verification to be performed by the measuring system shall be determined by
the results of the risk analysis.
NOTE It is desirable that the use of out-of-date reagents be prevented.
4.6.3 Control of system performance
The manufacturer shall provide a control procedure and instructions for the use of control materials.
The control procedure shall be validated. The requirements specified in ISO 15198 apply.
Control material may consist of a liquid control, an integrated control or a combination of both.
If a physical control is used (e.g., a check strip), the manufacturer shall provide instructions for when a
physical control shall be run on the instrument.
Before each measurement of a blood sample, a measurement verification shall be made by a monitor self-
check, using an internal or external physical control system.
Control measurements using liquid control materials shall be performed each time a new package of reagents
is used, when an unexpected result occurs, and as required by local regulations. Alternatively, liquid controls
may be replaced by an integrated functional control.
Actions to be taken when controls are out-of-range shall be given in the instructions for use.
4.6.4 Verification of self-testing performance
The manufacturer shall recommend a procedure for users to verify the acceptability of self-testing results.
Verification may be based on a comparison between results obtained by the user and a healthcare provider at
specified intervals. An interval of six months or less is recommended. With new self-testers, more frequent
intervals may be necessary to verify the technique, e.g. monthly.
4.6.5 Evaluation of user compliance in following the manufacturer’s and the physician’s
instructions
The manufacturer shall recommend, in the instructions for use for the healthcare professional, suitable
procedures for monitoring and evaluating user compliance with the manufacturer’s and the physician’s
instructions.
4.7 Metrological traceability
The requirements specified in ISO 17511 shall apply to the manufacturer’s process for calibrating the oral-
anticoagulation monitoring devices.
The measurement results of the manufacturer’s selected and/or standing measurement procedure shall be
traceable to those of the WHO manual tilt-tube measurement procedure using an International Reference
Preparation (IRP) of thromboplastin ([44] in the Bibliography).
NOTE 1 The WHO tilt-tube measurement procedure uses fresh, citrated plasma, whereas devices for self-testing use
fresh, untreated blood. Calibration of the devices involves parallel measurement of fresh plasma and blood from the same
patients. In this case, the blood samples are the calibrator.
10 Β© ISO 2007 – All rights reserved

If the manufacturer’s standing measurement procedure uses blood, then calibration of the procedure against
the WHO IRP and tilt-tube method shall occur through parallel measurement of blood and plasma. Calibration
of the end-user’s routine measurement procedure shall use blood.
If the manufacturer’s standing measurement procedure uses plasma, then plasma shall be used to calibrate
the procedure against the WHO IRP and tilt-tube method. Parallel measurement of plasma and blood shall
occur during calibration of the end-user’s routine measurement procedure (e.g., using the same lot of
reagents).
The traceability chain should include as few steps as practical, to minimize combined standard measurement
uncertainty.
NOTE 2 An example of a traceability chain for a typical factory-calibrated oral-anticoagulation monitoring system is
shown in Annex B, Figure B.1. The illustration of a full traceability c
...


ΠœΠ•Π–Π”Π£ΠΠΠ ΠžΠ”ΠΠ«Π™ ISO
БВАНДАРВ 17593
ΠŸΠ΅Ρ€Π²ΠΎΠ΅ ΠΈΠ·Π΄Π°Π½ΠΈΠ΅
2007-04-15
ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½Ρ‹Π΅
исслСдования ΠΈ in vitro мСдицинскиС
устройства. ВрСбования ΠΊ in vitro
систСмам контроля для самоконтроля
ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляционной
Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ
Clinical laboratory testing and in vitro medical devices β€” Requirements
for in vitro monitoring systems for self-testing of oral anticoagulant
therapy
ΠžΡ‚Π²Π΅Ρ‚ΡΡ‚Π²Π΅Π½Π½ΠΎΡΡ‚ΡŒ Π·Π° ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΡƒ русской вСрсии нСсёт GOST R
(Российская ЀСдСрация) Π² соотвСтствии со ΡΡ‚Π°Ρ‚ΡŒΡ‘ΠΉ 18.1 Устава ISO
Бсылочный Π½ΠΎΠΌΠ΅Ρ€
Β©
ISO 2007
ΠžΡ‚ΠΊΠ°Π· ΠΎΡ‚ отвСтствСнности ΠΏΡ€ΠΈ Ρ€Π°Π±ΠΎΡ‚Π΅ Π² PDF
Настоящий Ρ„Π°ΠΉΠ» PDF ΠΌΠΎΠΆΠ΅Ρ‚ ΡΠΎΠ΄Π΅Ρ€ΠΆΠ°Ρ‚ΡŒ ΠΈΠ½Ρ‚Π΅Π³Ρ€ΠΈΡ€ΠΎΠ²Π°Π½Π½Ρ‹Π΅ ΡˆΡ€ΠΈΡ„Ρ‚Ρ‹. Π’ соотвСтствии с условиями лицСнзирования, принятыми
Ρ„ΠΈΡ€ΠΌΠΎΠΉ Adobe, этот Ρ„Π°ΠΉΠ» ΠΌΠΎΠΆΠ½ΠΎ Ρ€Π°ΡΠΏΠ΅Ρ‡Π°Ρ‚Π°Ρ‚ΡŒ ΠΈΠ»ΠΈ ΡΠΌΠΎΡ‚Ρ€Π΅Ρ‚ΡŒ Π½Π° экранС, Π½ΠΎ Π΅Π³ΠΎ нСльзя ΠΈΠ·ΠΌΠ΅Π½ΠΈΡ‚ΡŒ, ΠΏΠΎΠΊΠ° Π½Π΅ Π±ΡƒΠ΄Π΅Ρ‚ ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π°
лицСнзия Π½Π° ΠΈΠ½Ρ‚Π΅Π³Ρ€ΠΈΡ€ΠΎΠ²Π°Π½Π½Ρ‹Π΅ ΡˆΡ€ΠΈΡ„Ρ‚Ρ‹ ΠΈ ΠΎΠ½ΠΈ Π½Π΅ Π±ΡƒΠ΄ΡƒΡ‚ установлСны Π½Π° ΠΊΠΎΠΌΠΏΡŒΡŽΡ‚Π΅Ρ€Π΅, Π½Π° ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠΌ вСдСтся Ρ€Π΅Π΄Π°ΠΊΡ‚ΠΈΡ€ΠΎΠ²Π°Π½ΠΈΠ΅. Π’
случаС Π·Π°Π³Ρ€ΡƒΠ·ΠΊΠΈ настоящСго Ρ„Π°ΠΉΠ»Π° заинтСрСсованныС стороны ΠΏΡ€ΠΈΠ½ΠΈΠΌΠ°ΡŽΡ‚ Π½Π° сСбя ΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²Π΅Π½Π½ΠΎΡΡ‚ΡŒ Π·Π° соблюдСниС
Π»ΠΈΡ†Π΅Π½Π·ΠΈΠΎΠ½Π½Ρ‹Ρ… условий Ρ„ΠΈΡ€ΠΌΡ‹ Adobe. Π¦Π΅Π½Ρ‚Ρ€Π°Π»ΡŒΠ½Ρ‹ΠΉ сСкрСтариат ISO Π½Π΅ нСсСт Π½ΠΈΠΊΠ°ΠΊΠΎΠΉ отвСтствСнности Π² этом ΠΎΡ‚Π½ΠΎΡˆΠ΅Π½ΠΈΠΈ.
Adobe - Ρ‚ΠΎΡ€Π³ΠΎΠ²Ρ‹ΠΉ Π·Π½Π°ΠΊ Ρ„ΠΈΡ€ΠΌΡ‹ Adobe Systems Incorporated.
ΠŸΠΎΠ΄Ρ€ΠΎΠ±Π½ΠΎΡΡ‚ΠΈ, относящиСся ΠΊ ΠΏΡ€ΠΎΠ³Ρ€Π°ΠΌΠΌΠ½Ρ‹ΠΌ ΠΏΡ€ΠΎΠ΄ΡƒΠΊΡ‚Π°ΠΌ, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π½Π½Ρ‹Π΅ для создания настоящСго Ρ„Π°ΠΉΠ»Π° PDF, ΠΌΠΎΠΆΠ½ΠΎ Π½Π°ΠΉΡ‚ΠΈ Π²
Ρ€ΡƒΠ±Ρ€ΠΈΠΊΠ΅ General Info Ρ„Π°ΠΉΠ»Π°; ΠΏΠ°Ρ€Π°ΠΌΠ΅Ρ‚Ρ€Ρ‹ создания PDF Π±Ρ‹Π»ΠΈ ΠΎΠΏΡ‚ΠΈΠΌΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Π½Ρ‹ для ΠΏΠ΅Ρ‡Π°Ρ‚ΠΈ. Π‘Ρ‹Π»ΠΈ приняты Π²ΠΎ Π²Π½ΠΈΠΌΠ°Π½ΠΈΠ΅ всС
ΠΌΠ΅Ρ€Ρ‹ прСдостороТности с Ρ‚Π΅ΠΌ, Ρ‡Ρ‚ΠΎΠ±Ρ‹ ΠΎΠ±Π΅ΡΠΏΠ΅Ρ‡ΠΈΡ‚ΡŒ ΠΏΡ€ΠΈΠ³ΠΎΠ΄Π½ΠΎΡΡ‚ΡŒ настоящСго Ρ„Π°ΠΉΠ»Π° для использования ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚Π°ΠΌΠΈ-Ρ‡Π»Π΅Π½Π°ΠΌΠΈ
ISO. Π’ Ρ€Π΅Π΄ΠΊΠΈΡ… случаях возникновСния ΠΏΡ€ΠΎΠ±Π»Π΅ΠΌΡ‹, связанной со сказанным Π²Ρ‹ΡˆΠ΅, ΠΏΡ€ΠΎΡΡŒΠ±Π° ΠΏΡ€ΠΎΠΈΠ½Ρ„ΠΎΡ€ΠΌΠΈΡ€ΠΎΠ²Π°Ρ‚ΡŒ Π¦Π΅Π½Ρ‚Ρ€Π°Π»ΡŒΠ½Ρ‹ΠΉ
сСкрСтариат ΠΏΠΎ адрСсу, ΠΏΡ€ΠΈΠ²Π΅Π΄Π΅Π½Π½ΠΎΠΌΡƒ Π½ΠΈΠΆΠ΅.

Π”ΠžΠšΠ£ΠœΠ•ΠΠ’ Π—ΠΠ©Π˜Π©Π•Π ΠΠ’Π’ΠžΠ Π‘ΠšΠ˜Πœ ΠŸΠ ΠΠ’ΠžΠœ

ВсС ΠΏΡ€Π°Π²Π° ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ. Если Π½Π΅ ΡƒΠΊΠ°Π·Π°Π½ΠΎ ΠΈΠ½ΠΎΠ΅, Π½ΠΈΠΊΠ°ΠΊΡƒΡŽ Ρ‡Π°ΡΡ‚ΡŒ настоящСй ΠΏΡƒΠ±Π»ΠΈΠΊΠ°Ρ†ΠΈΠΈ нСльзя ΠΊΠΎΠΏΠΈΡ€ΠΎΠ²Π°Ρ‚ΡŒ ΠΈΠ»ΠΈ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚ΡŒ Π²
ΠΊΠ°ΠΊΠΎΠΉ-Π»ΠΈΠ±ΠΎ Ρ„ΠΎΡ€ΠΌΠ΅ ΠΈΠ»ΠΈ ΠΊΠ°ΠΊΠΈΠΌ-Π»ΠΈΠ±ΠΎ элСктронным ΠΈΠ»ΠΈ мСханичСским способом, Π²ΠΊΠ»ΡŽΡ‡Π°Ρ Ρ„ΠΎΡ‚ΠΎΠΊΠΎΠΏΠΈΠΈ ΠΈ ΠΌΠΈΠΊΡ€ΠΎΡ„ΠΈΠ»ΡŒΠΌΡ‹, Π±Π΅Π·
ΠΏΡ€Π΅Π΄Π²Π°Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠ³ΠΎ письмСнного согласия ISO ΠΏΠΎ адрСсу Π½ΠΈΠΆΠ΅ ΠΈΠ»ΠΈ ΠΏΡ€Π΅Π΄ΡΡ‚Π°Π²ΠΈΡ‚Π΅Π»ΡŒΡΡ‚Π²Π° ISO Π² ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‰Π΅ΠΉ странС.
ISO copyright office
Case postale 56 β€’ CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
ΠžΠΏΡƒΠ±Π»ΠΈΠΊΠΎΠ²Π°Π½ΠΎ Π² Π¨Π²Π΅ΠΉΡ†Π°Ρ€ΠΈΠΈ
ii Β© ISO 2007 – ВсС ΠΏΡ€Π°Π²Π° ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ

Π‘ΠΎΠ΄Π΅Ρ€ΠΆΠ°Π½ΠΈΠ΅ Π‘Ρ‚Ρ€Π°Π½ΠΈΡ†Π°
ΠŸΡ€Π΅Π΄ΠΈΡΠ»ΠΎΠ²ΠΈΠ΅ .v
Π’Π²Π΅Π΄Π΅Π½ΠΈΠ΅ .vi
1 ΠžΠ±Π»Π°ΡΡ‚ΡŒ примСнСния .1
2 НормативныС ссылки .1
3 Π’Π΅Ρ€ΠΌΠΈΠ½Ρ‹ ΠΈ опрСдСлСния .2
4 ΠŸΡ€ΠΎΠ΅ΠΊΡ‚ΠΈΡ€ΠΎΠ²Π°Π½ΠΈΠ΅ ΠΈ Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° .9
4.1 ΠžΠ±Ρ‰ΠΈΠ΅ трСбования .9
4.2 Π˜Π·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΉ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π» .9
4.3 Π‘Π΅Π·ΠΎΠΏΠ°ΡΠ½ΠΎΡΡ‚ΡŒ.9
4.4 Π£ΠΏΡ€Π°Π²Π»Π΅Π½ΠΈΠ΅ риском.9
4.4.1 Π”ΠΎΠΏΡƒΡΡ‚ΠΈΠΌΠΎΡΡ‚ΡŒ рисков .9
4.4.2 ΠžΡ†Π΅Π½ΠΊΠ° риска .9
4.5 ЭргономичСскиС аспСкты ΠΈ аспСкты чСловСчСского Ρ„Π°ΠΊΡ‚ΠΎΡ€Π°.10
4.6 ΠžΠ±Π΅ΡΠΏΠ΅Ρ‡Π΅Π½ΠΈΠ΅ качСства ΠΈ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ риска .10
4.6.1 ΠžΠ±Ρ‰Π΅Π΅.10
4.6.2 ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ измСрСния.11
4.6.3 ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ систСмы .11
4.6.4 ΠŸΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ° функционирования самоконтроля .11
4.6.5 ΠžΡ†Π΅Π½ΠΊΠ° соотвСтствия ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Ρ ΠΏΠΎΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠΌ инструкциям производитСля ΠΈ
Π²Ρ€Π°Ρ‡Π° .11
4.7 ΠœΠ΅Ρ‚Ρ€ΠΎΠ»ΠΎΠ³ΠΈΡ‡Π΅ΡΠΊΠΎΠ΅ Сдинство ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ.12
5 Π˜Π½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡ, прСдоставляСмая ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ.12
5.1 ΠžΠ±Ρ‰ΠΈΠ΅ трСбования .12
5.2 ΠžΡ‚ΠΌΠ΅Ρ‚ΠΊΠΈ инструмСнта контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции.13
5.3 Π˜Π½ΡΡ‚Ρ€ΡƒΠΊΡ†ΠΈΠΈ ΠΏΠΎ эксплуатации систСмы контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции.13
5.4 ΠžΡ‚ΠΌΠ΅Ρ‚ΠΊΠΈ Ρ€Π΅Π°Π³Π΅Π½Ρ‚ΠΎΠ² ΠΈ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½ΠΎΠ³ΠΎ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»Π°.15
5.5 Π˜Π½ΡΡ‚Ρ€ΡƒΠΊΡ†ΠΈΠΈ ΠΏΠΎ ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡŽ Ρ€Π΅Π°Π³Π΅Π½Ρ‚ΠΎΠ² ΠΈ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½ΠΎΠ³ΠΎ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ»Π° .15
6 Π˜ΡΠΏΡ‹Ρ‚Π°Π½ΠΈΡ Π½Π° Π±Π΅Π·ΠΎΠΏΠ°ΡΠ½ΠΎΡΡ‚ΡŒ ΠΈ Π½Π°Π΄Π΅ΠΆΠ½ΠΎΡΡ‚ΡŒ.16
6.1 ΠžΠ±Ρ‰ΠΈΠ΅ трСбования .16
6.1.1 ΠŸΡ€ΠΎΡ‚ΠΎΠΊΠΎΠ» .16
6.1.2 Π˜Π½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Ρ‹ ΠΈ Ρ€Π΅Π°Π³Π΅Π½Ρ‚Ρ‹ .16
6.1.3 ΠšΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠΉ ΠΏΡ€ΠΈΠ΅ΠΌΠΊΠΈ .16
6.2 Π—Π°Ρ‰ΠΈΡ‚Π° ΠΎΡ‚ элСктричСского ΡƒΠ΄Π°Ρ€Π°.17
6.3 Π—Π°Ρ‰ΠΈΡ‚Π° ΠΎΡ‚ мСханичСских опасностСй .17
6.4 ЭлСктромагнитная ΡΠΎΠ²ΠΌΠ΅ΡΡ‚ΠΈΠΌΠΎΡΡ‚ΡŒ .17
6.5 Π£ΡΡ‚ΠΎΠΉΡ‡ΠΈΠ²ΠΎΡΡ‚ΡŒ ΠΊ Ρ‚Π΅ΠΏΠ»Ρƒ .17
6.6 Π£ΡΡ‚ΠΎΠΉΡ‡ΠΈΠ²ΠΎΡΡ‚ΡŒ ΠΊ влаТности ΠΈ Тидкостям .17
6.7 Π—Π°Ρ‰ΠΈΡ‚Π° ΠΎΡ‚ свободных Π³Π°Π·ΠΎΠ², воспламСнСния ΠΈ ΠΈΠΌΠΏΠ»ΠΎΠ·ΠΈΠΈ.17
6.8 Π˜Π½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½Ρ‹Π΅ ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚Ρ‹ .17
6.9 ЭксплуатационныС испытания .17
6.10 ΠœΠ΅Ρ…Π°Π½ΠΈΡ‡Π΅ΡΠΊΠ°Ρ ΡƒΡΡ‚ΠΎΠΉΡ‡ΠΈΠ²ΠΎΡΡ‚ΡŒ ΠΊ ΡƒΠ΄Π°Ρ€Ρƒ, Π²ΠΈΠ±Ρ€Π°Ρ†ΠΈΠΈ ΠΈ ΡΡ‚ΠΎΠ»ΠΊΠ½ΠΎΠ²Π΅Π½ΠΈΡŽ.18
6.10.1 ΠŸΡ€ΠΎΡ‚ΠΎΠΊΠΎΠ» испытания Π½Π° Π²ΠΈΠ±Ρ€ΠΎΡƒΡΡ‚ΠΎΠΉΡ‡ΠΈΠ²ΠΎΡΡ‚ΡŒ .18
6.10.2 ΠŸΡ€ΠΎΡ‚ΠΎΠΊΠΎΠ» испытания Π½Π° ΡƒΠ΄Π°Ρ€.18
6.11 ΠŸΡ€Π΅Π΄Π΅Π»Ρ‹ Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€Π½ΠΎΠ³ΠΎ воздСйствия .18
6.11.1 ΠŸΡ€ΠΎΡ‚ΠΎΠΊΠΎΠ» высокотСмпСратурного испытания.18
6.11.2 ΠŸΡ€ΠΎΡ‚ΠΎΠΊΠΎΠ» Π½ΠΈΠ·ΠΊΠΎΡ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€Π½ΠΎΠ³ΠΎ воздСйствия .19
6.12 ΠŸΡ€ΠΎΡ‚ΠΎΠΊΠΎΠ» испытания воздСйствия влаТности.19
6.13 Π₯Ρ€Π°Π½Π΅Π½ΠΈΠ΅ Ρ€Π΅Π°Π³Π΅Π½Ρ‚Π° ΠΈ эксплуатационноС испытаниС .19
7 ΠŸΡ€ΠΎΠ³Ρ€Π°ΠΌΠΌΡ‹ ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΠΈ ΠΈ обучСния. 19
7.1 ΠŸΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΠ° поставщиков Π² области здравоохранСния . 19
7.2 ΠžΠ±ΡƒΡ‡Π΅Π½ΠΈΠ΅ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² ΠΈ Π΄Ρ€ΡƒΠ³ΠΈΡ… ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Π΅ΠΉ . 20
8 ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ систСмы. 21
8.1 ΠžΠ±Ρ‰Π΅Π΅. 21
8.2 Π’ΠΊΠ»Π°Π΄Ρ‹ Π² ΠΏΠΎΠ³Ρ€Π΅ΡˆΠ½ΠΎΡΡ‚ΡŒ измСрСния. 21
8.3 ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½ΠΎΠ΅ исслСдованиС ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ систСмы . 21
8.4 ΠŸΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ° прСцизионности измСрСния. 22
8.4.1 ΠžΠ±Ρ‰Π΅Π΅. 22
8.4.2 ΠŸΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ° повторяСмости измСрСния . 22
8.4.3 ΠŸΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ° срСднСй прСцизионности измСрСния. 23
8.4.4 Анализ Π΄Π°Π½Π½Ρ‹Ρ… . 24
8.5 ΠŸΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ° точности систСмы . 27
8.5.1 ΠžΠ±Ρ‰ΠΈΠ΅ трСбования. 27
8.5.2 Π˜ΡΡΠ»Π΅Π΄ΡƒΠ΅ΠΌΠ°Ρ Π³Π΅Π½Π΅Ρ€Π°Π»ΡŒΠ½Π°Ρ ΡΠΎΠ²ΠΎΠΊΡƒΠΏΠ½ΠΎΡΡ‚ΡŒ . 27
8.5.3 ΠžΠ±Ρ€Π°Π·Ρ†Ρ‹. 27
8.5.4 Π˜Π½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Ρ‹ ΠΈ Ρ€Π΅Π°Π³Π΅Π½Ρ‚Ρ‹ . 28
8.5.5 ΠœΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° измСрСния, выбранная ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ. 28
8.5.6 ИсслСдованиС Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠΈ . 29
8.5.7 ΠœΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ°. 29
8.5.8 Анализ Π΄Π°Π½Π½Ρ‹Ρ… . 31
8.6 Минимальная допустимая Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ систСмы . 34
8.6.1 Π’Ρ€Π΅Π±ΠΎΠ²Π°Π½ΠΈΠ΅ точности систСмы . 34
8.6.2 ΠžΡ†Π΅Π½ΠΊΠ° точности систСмы. 35
8.6.3 ΠŸΡ€Π΅Π΄ΡΡ‚Π°Π²Π»Π΅Π½ΠΈΠ΅ Π΄Π°Π½Π½Ρ‹Ρ… . 35
9 ΠžΡ†Π΅Π½ΠΊΠ° характСристик ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Ρ. 35
9.1 ΠžΠ±Ρ‰Π΅Π΅. 35
9.2 ΠœΠ΅ΡΡ‚ΠΎ провСдСния исслСдования . 36
9.3 Π‘ΡƒΠ±ΡŠΠ΅ΠΊΡ‚Ρ‹. 36
9.4 Π˜Π½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Ρ‹ ΠΈ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»Ρ‹. 36
9.5 ΠžΡ†Π΅Π½ΠΊΠ° ΠΊΠ²Π°Π»ΠΈΡ„ΠΈΠΊΠ°Ρ†ΠΈΠΈ ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Ρ . 36
9.6 ΠšΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠΉ ΠΏΡ€ΠΈΠ΅ΠΌΠΊΠΈ ΠΈ ΠΎΡ†Π΅Π½ΠΊΠ° Π΄Π°Π½Π½Ρ‹Ρ… . 37
9.7 ΠžΡ†Π΅Π½ΠΊΠ° инструкций ΠΏΠΎ эксплуатации. 38
ΠŸΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ A (Π½ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½ΠΎΠ΅) Π”ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ трСбования ΠΊ элСктромагнитной
совмСстимости . 39
ΠŸΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ B (ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½ΠΎΠ΅) ΠŸΡ€ΠΈΠΌΠ΅Ρ€Ρ‹ ΠΏΠΎΡΠ»Π΅Π΄ΠΎΠ²Π°Ρ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ ΠΎΠΏΠ΅Ρ€Π°Ρ‚ΠΈΠ²Π½ΠΎΠ³ΠΎ контроля . 41
ΠŸΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ C (ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½ΠΎΠ΅) ΠŸΡ€ΠΈΠΌΠ΅Ρ€ числСнного расчСта для ΠΎΡ†Π΅Π½ΠΊΠΈ систСматичСской
ошибки ([42] Π² Π‘ΠΈΠ±Π»ΠΈΠΎΠ³Ρ€Π°Ρ„ΠΈΠΈ). 44
ΠŸΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ D (ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½ΠΎΠ΅) ΠŸΡ€ΠΈΠΌΠ΅Ρ€ вычислСния ΠΏΠΎΠ³Ρ€Π΅ΡˆΠ½ΠΎΡΡ‚ΠΈ опрСдСлСния INR
ΠΏΡ€ΠΎΡ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½Π°, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΡ систСму контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции . 45
ΠŸΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ E (ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½ΠΎΠ΅) Π­Π»Π΅ΠΌΠ΅Π½Ρ‚Ρ‹ обСспСчСния качСства систСм контроля
ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции . 49
ΠŸΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ F (ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½ΠΎΠ΅) ΠŸΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ критСрия эффСктивности для
ΠΎΠΏΡƒΠ±Π»ΠΈΠΊΠΎΠ²Π°Π½Π½Ρ‹Ρ… ΠΎΡ†Π΅Π½ΠΎΠΊ систСм контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции . 50
Библиография . 57

iv Β© ISO 2007 – ВсС ΠΏΡ€Π°Π²Π° ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ

ΠŸΡ€Π΅Π΄ΠΈΡΠ»ΠΎΠ²ΠΈΠ΅
ΠœΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Π°Ρ организация ΠΏΠΎ стандартизации (ISO) являСтся всСмирной Ρ„Π΅Π΄Π΅Ρ€Π°Ρ†ΠΈΠ΅ΠΉ Π½Π°Ρ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹Ρ…
ΠΎΡ€Π³Π°Π½ΠΈΠ·Π°Ρ†ΠΈΠΉ ΠΏΠΎ стандартизации (ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚ΠΎΠ²-Ρ‡Π»Π΅Π½ΠΎΠ² ISO). Π Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Ρ… стандартов
ΠΎΠ±Ρ‹Ρ‡Π½ΠΎ осущСствляСтся тСхничСскими ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚Π°ΠΌΠΈ ISO. ΠšΠ°ΠΆΠ΄Ρ‹ΠΉ ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚-Ρ‡Π»Π΅Π½, заинтСрСсованный Π²
Π΄Π΅ΡΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ, для ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠΉ Π±Ρ‹Π» создан тСхничСский ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚, ΠΈΠΌΠ΅Π΅Ρ‚ ΠΏΡ€Π°Π²ΠΎ Π±Ρ‹Ρ‚ΡŒ прСдставлСнным Π² этом
ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚Π΅. ΠœΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Π΅ ΠΏΡ€Π°Π²ΠΈΡ‚Π΅Π»ΡŒΡΡ‚Π²Π΅Π½Π½Ρ‹Π΅ ΠΈ Π½Π΅ΠΏΡ€Π°Π²ΠΈΡ‚Π΅Π»ΡŒΡΡ‚Π²Π΅Π½Π½Ρ‹Π΅ ΠΎΡ€Π³Π°Π½ΠΈΠ·Π°Ρ†ΠΈΠΈ, ΠΈΠΌΠ΅ΡŽΡ‰ΠΈΠ΅ связи с
ISO, Ρ‚Π°ΠΊΠΆΠ΅ ΠΏΡ€ΠΈΠ½ΠΈΠΌΠ°ΡŽΡ‚ участиС Π² Ρ€Π°Π±ΠΎΡ‚Π°Ρ…. Π§Ρ‚ΠΎ касаСтся стандартизации Π² области элСктротСхники, Ρ‚ΠΎ
ISO Ρ€Π°Π±ΠΎΡ‚Π°Π΅Ρ‚ Π² тСсном сотрудничСствС с ΠœΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠΉ элСктротСхничСской комиссиСй (IEC).
ΠŸΡ€ΠΎΠ΅ΠΊΡ‚Ρ‹ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Ρ… стандартов Ρ€Π°Π·Ρ€Π°Π±Π°Ρ‚Ρ‹Π²Π°ΡŽΡ‚ΡΡ Π² соотвСтствии с ΠΏΡ€Π°Π²ΠΈΠ»Π°ΠΌΠΈ Π”ΠΈΡ€Π΅ΠΊΡ‚ΠΈΠ² ISO/IEC,
Π§Π°ΡΡ‚ΡŒ 2.
Основная Π·Π°Π΄Π°Ρ‡Π° тСхничСских ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚ΠΎΠ² Π·Π°ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ΡΡ Π² ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΠ΅ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Ρ… стандартов.
ΠŸΡ€ΠΎΠ΅ΠΊΡ‚Ρ‹ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Ρ… стандартов, принятыС тСхничСскими ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚Π°ΠΌΠΈ, Ρ€Π°ΡΡΡ‹Π»Π°ΡŽΡ‚ΡΡ ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚Π°ΠΌ-
Ρ‡Π»Π΅Π½Π°ΠΌ Π½Π° голосованиС. Π˜Ρ… ΠΎΠΏΡƒΠ±Π»ΠΈΠΊΠΎΠ²Π°Π½ΠΈΠ΅ Π² качСствС ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Ρ… стандартов Ρ‚Ρ€Π΅Π±ΡƒΠ΅Ρ‚ одобрСния
Π½Π΅ ΠΌΠ΅Π½Π΅Π΅ 75 % ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚ΠΎΠ²-Ρ‡Π»Π΅Π½ΠΎΠ², ΠΏΡ€ΠΈΠ½ΠΈΠΌΠ°ΡŽΡ‰ΠΈΡ… участиС Π² голосовании.
Π‘Π»Π΅Π΄ΡƒΠ΅Ρ‚ ΠΈΠΌΠ΅Ρ‚ΡŒ Π² Π²ΠΈΠ΄Ρƒ, Ρ‡Ρ‚ΠΎ Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ элСмСнты настоящСго ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠ³ΠΎ стандарта ΠΌΠΎΠ³ΡƒΡ‚ Π±Ρ‹Ρ‚ΡŒ
ΠΎΠ±ΡŠΠ΅ΠΊΡ‚ΠΎΠΌ ΠΏΠ°Ρ‚Π΅Π½Ρ‚Π½Ρ‹Ρ… ΠΏΡ€Π°Π². ISO Π½Π΅ ΠΌΠΎΠΆΠ΅Ρ‚ нСсти ΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²Π΅Π½Π½ΠΎΡΡ‚ΡŒ Π·Π° ΠΈΠ΄Π΅Π½Ρ‚ΠΈΡ„ΠΈΠΊΠ°Ρ†ΠΈΡŽ ΠΊΠ°ΠΊΠΎΠ³ΠΎ-Π»ΠΈΠ±ΠΎ ΠΎΠ΄Π½ΠΎΠ³ΠΎ
ΠΈΠ»ΠΈ всСх ΠΏΠ°Ρ‚Π΅Π½Ρ‚Π½Ρ‹Ρ… ΠΏΡ€Π°Π².
ISO 17593 Π±Ρ‹Π» ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²Π»Π΅Π½ ВСхничСским ΠΊΠΎΠΌΠΈΡ‚Π΅Ρ‚ΠΎΠΌ ISO/TC 212, ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½Ρ‹Π΅
исслСдования ΠΈ in vitro диагностичСскиС ΠΈΡΠΏΡ‹Ρ‚Π°Ρ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ систСмы.
Π’Π²Π΅Π΄Π΅Π½ΠΈΠ΅
БистСмы контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции ΡΠ²Π»ΡΡŽΡ‚ΡΡ in vitro диагностичСскими мСдицинскими
устройствами, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ ΠΈΠ·ΠΌΠ΅Ρ€ΡΡŽΡ‚ ΠΏΡ€ΠΎΡ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½ΠΎΠ²ΠΎΠ΅ врСмя Π² свСТих, Π½Π΅ΠΈΠ·ΠΌΠ΅Π½Π΅Π½Π½Ρ‹Ρ… ΠΎΠ±Ρ€Π°Π·Ρ†Π°Ρ…
чСловСчСской ΠΊΡ€ΠΎΠ²ΠΈ. ΠŸΡ€ΠΎΡ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½ΠΎΠ²ΠΎΠ΅ врСмя являСтся ΠΏΠΎΠΊΠ°Π·Π°Ρ‚Π΅Π»Π΅ΠΌ способности ΠΊΡ€ΠΎΠ²ΠΈ ΠΊ ΡΠ²Π΅Ρ€Ρ‚Ρ‹Π²Π°Π½ΠΈΡŽ.
In vitro диагностичСскиС мСдицинскиС устройства для самоконтроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагулянтной
Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΡŽΡ‚ΡΡ прСимущСствСнно Π»ΠΈΡ†Π°ΠΌΠΈ, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ ΠΈΠΌΠ΅ΡŽΡ‚ Π·Π°ΠΌΠ΅Ρ‰Π΅Π½Π½Ρ‹Π΅ сСрдСчныС ΠΊΠ»Π°ΠΏΠ°Π½Ρ‹ ΠΈΠ»ΠΈ
ΡΡ‚Ρ€Π°Π΄Π°ΡŽΡ‚ ΠΌΠ΅Ρ€Ρ†Π°Ρ‚Π΅Π»ΡŒΠ½ΠΎΠΉ Π°Ρ€ΠΈΡ‚ΠΌΠΈΠ΅ΠΉ ΠΈΠ»ΠΈ Π³Π»ΡƒΠ±ΠΎΠΊΠΈΠΌ Ρ‚Ρ€ΠΎΠΌΠ±ΠΎΠ·ΠΎΠΌ Π²Π΅Π½. ΠŸΠ°Ρ†ΠΈΠ΅Π½Ρ‚Ρ‹ Π΄ΠΎΠ»ΠΆΠ½Ρ‹ ΠΏΠΎΠ΄Π΄Π΅Ρ€ΠΆΠΈΠ²Π°Ρ‚ΡŒ
ΡƒΡ€ΠΎΠ²Π΅Π½ΡŒ антикоагулянта Π² ΠΊΡ€ΠΎΠ²ΠΈ достаточно высоким для ΡƒΠΌΠ΅Π½ΡŒΡˆΠ΅Π½ΠΈΡ образования Ρ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½Π°, ΠΈ, Π² Ρ‚ΠΎ
ΠΆΠ΅ врСмя, достаточно Π½ΠΈΠ·ΠΊΠΈΠΌ для прСдотвращСния Ρ‡Ρ€Π΅Π·ΠΌΠ΅Ρ€Π½ΠΎΠ³ΠΎ кровотСчСния. БистСма контроля
антикоагуляции позволяСт ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡŽ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΠΈΡ€ΠΎΠ²Π°Ρ‚ΡŒ Π°Π½Ρ‚ΠΈΠΊΠΎΠ°Π³ΡƒΠ»ΡΡ†ΠΈΠΎΠ½Π½ΡƒΡŽ Ρ‚Π΅Ρ€Π°ΠΏΠΈΡŽ ΠΈ
ΠΏΡ€Π΅Π΄ΠΏΡ€ΠΈΠ½ΠΈΠΌΠ°Ρ‚ΡŒ дСйствия для контроля уровня антикоагулянта, ΠΏΡ€ΠΈΡΡƒΡ‚ΡΡ‚Π²ΡƒΡŽΡ‰Π΅Π³ΠΎ Π² ΠΊΡ€ΠΎΠ²ΠΈ.
Π”Π°Π½Π½Ρ‹ΠΉ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹ΠΉ стандарт примСняСтся ΠΊ систСмам контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции,
ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅ΠΌΡ‹ΠΌ нСпрофСссионалами. ΠžΡΠ½ΠΎΠ²Π½Ρ‹ΠΌΠΈ Π·Π°Π΄Π°Ρ‡Π°ΠΌΠΈ ΡΠ²Π»ΡΡŽΡ‚ΡΡ ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½ΠΈΠ΅ Ρ‚Ρ€Π΅Π±ΠΎΠ²Π°Π½ΠΈΠΉ для
систСм контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ позволят ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡΠΌ-нСпрофСссионалам
Π΄ΠΎΠ±ΠΈΠ²Π°Ρ‚ΡŒΡΡ ΠΏΡ€ΠΈΠ΅ΠΌΠ»Π΅ΠΌΠΎΠ³ΠΎ функционирования, ΠΈ ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½ΠΈΠ΅ ΠΏΡ€ΠΎΡ†Π΅Π΄ΡƒΡ€ для ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΉ ΠΈ Π΄Ρ€ΡƒΠ³ΠΈΡ…
заинтСрСсованных сторон для дСмонстрации соотвСтствия Ρ‚Π°ΠΊΠΈΡ… систСм Π΄Π°Π½Π½ΠΎΠΌΡƒ стандарту.
ΠšΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠΉ эффСктивности для систСм контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции установлСн ΠΈ основан Π½Π°
ΠΏΡ€Π΅Π΄ΠΏΠΎΠ»Π°Π³Π°Π΅ΠΌΠΎΠΉ Ρ€Π΅Π°Π»ΡŒΠ½ΠΎΠΉ сущСствСнной пользС для ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Π°, которая Π±Ρ‹Π»Π° ΠΏΠΎΠΊΠ°Π·Π° [68], [69].
ΠšΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠΉ ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½ Π² Ρ‚Π΅Ρ€ΠΌΠΈΠ½Π°Ρ… β€œΡ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ систСмы”, Ρ‚Π°ΠΊ ΠΊΠ°ΠΊ мСтрологичСскиС Ρ‚Π΅Ρ€ΠΌΠΈΠ½Ρ‹, ΠΎΠ±Ρ‹Ρ‡Π½ΠΎ
ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅ΠΌΡ‹Π΅ Π² ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Ρ… стандартах (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ ΠΈ ΠΏΠΎΠ³Ρ€Π΅ΡˆΠ½ΠΎΡΡ‚ΡŒ измСрСния) Π½Π΅
Π΄ΠΎΠ»ΠΆΠ½Ρ‹ Π±Ρ‹Ρ‚ΡŒ Π·Π½Π°ΠΊΠΎΠΌΡ‹ ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡΠΌ-нСпрофСссионалам. Π’ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ систСмы, которая зависит ΠΎΡ‚
систСматичСской ошибки ΠΈ случайных эффСктов (ΠΈ связана ΠΎΠ±Ρ€Π°Ρ‚Π½ΠΎΠΉ Π·Π°Π²ΠΈΡΠΈΠΌΠΎΡΡ‚ΡŒΡŽ с ΠΏΠΎΠ³Ρ€Π΅ΡˆΠ½ΠΎΡΡ‚ΡŒΡŽ
измСрСния), опрСдСляСт ΡƒΡ€ΠΎΠ²Π΅Π½ΡŒ, ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠΌΡƒ ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‚ ΠΎΡ‚Π΄Π΅Π»ΡŒΠ½Ρ‹Π΅ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹, ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½Ρ‹Π΅
систСмой контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции, с ΠΏΡ€Π°Π²ΠΈΠ»ΡŒΠ½Ρ‹ΠΌΠΈ INR значСниями, ΠΏΡ€ΠΈ использовании
систСмы, ΠΊΠ°ΠΊ ΠΏΡ€Π΅Π΄ΠΏΠΎΠ»Π°Π³Π°Π»ΠΎΡΡŒ, нСпрофСссионалами.
ΠŸΡ€ΠΈ установкС критСрия эффСктивности прСдполагаСтся, Ρ‡Ρ‚ΠΎ ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΠΈ Π±ΡƒΠ΄ΡƒΡ‚ ΠΏΠΎΠ΄ΠΎΠ±Ρ€Π°Π½Ρ‹
Π½Π°Π΄Π»Π΅ΠΆΠ°Ρ‰ΠΈΠΌ ΠΎΠ±Ρ€Π°Π·ΠΎΠΌ ΠΈ ΠΏΠΎΠ»ΡƒΡ‡Π°Ρ‚ Π½Π΅ΠΎΠ±Ρ…ΠΎΠ΄ΠΈΠΌΡƒΡŽ ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΡƒ, Ρ‡Ρ‚ΠΎ устройство Π±ΡƒΠ΄Π΅Ρ‚ установлСно Π΄ΠΎΠ»ΠΆΠ½Ρ‹ΠΌ
ΠΎΠ±Ρ€Π°Π·ΠΎΠΌ, ΠΈ Ρ‡Ρ‚ΠΎ ΠΏΡ€ΠΎΡ†Π΅Π΄ΡƒΡ€Ρ‹ Ρ€Π°Π±ΠΎΡ‚Ρ‹ ΠΈ контроля Π±ΡƒΠ΄ΡƒΡ‚ ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΠΎΠ²Π°Ρ‚ΡŒ инструкциям ΠΏΠΎ ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡŽ
производитСля. Π’Π°ΠΊΠΆΠ΅ прСдполагаСтся, Ρ‡Ρ‚ΠΎ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΠΈ Π±ΡƒΠ΄ΡƒΡ‚ ΠΏΡ€Π΅Π΄ΡƒΠΏΡ€Π΅ΠΆΠ΄Π°Ρ‚ΡŒ ΠΈ ΡƒΠΌΠ΅Π½ΡŒΡˆΠ°Ρ‚ΡŒ
эффСкты достаточно прСдсказуСмого Π½Π΅ΠΏΡ€Π°Π²ΠΈΠ»ΡŒΠ½ΠΎΠ³ΠΎ примСнСния, Π²ΠΊΠ»ΡŽΡ‡Π°Ρ ΡƒΠΌΠ΅Ρ€Π΅Π½Π½ΠΎ прСдсказуСмыС
отклонСния ΠΎΡ‚ Ρ€Π΅ΠΊΠΎΠΌΠ΅Π½Π΄ΠΎΠ²Π°Π½Π½ΠΎΠΉ эксплуатации, ΠΏΡ€ΠΎΡ†Π΅Π΄ΡƒΡ€ Ρ€Π°Π±ΠΎΡ‚Ρ‹ ΠΈ контроля ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Π½Ρ‹ΠΌΠΈ
ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡΠΌΠΈ.
ВрСбования, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ относятся ΠΈΡΠΊΠ»ΡŽΡ‡ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ ΠΊ ΡΠ°ΠΌΠΎΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŽ с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ систСм контроля
ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции, Π²ΠΊΠ»ΡŽΡ‡Π°Ρ содСрТаниС ΠΈΠ½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΠΈ, прСдоставляСмой ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ,
Ρ€Π°ΡΡΠΌΠ°Ρ‚Ρ€ΠΈΠ²Π°ΡŽΡ‚ΡΡ Π² Π΄Π°Π½Π½ΠΎΠΌ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠΌ стандартС. ΠžΠ±Ρ‰ΠΈΠ΅ трСбования, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ ΠΏΡ€ΠΈΠΌΠ΅Π½ΡΡŽΡ‚ΡΡ ΠΊΠΎ
всСм in vitro диагностичСским мСдицинским устройствам, ΠΈ ΠΎΡ…Π²Π°Ρ‡Π΅Π½Π½Ρ‹Π΅ Π΄Ρ€ΡƒΠ³ΠΈΠΌΠΈ стандартами
(Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, IEC 61010, ISO 13485, ISO 14971 ΠΈ ISO 18113) ΠΎΠ±ΡŠΠ΅Π΄ΠΈΠ½Π΅Π½Ρ‹ ссылкой, Π³Π΄Π΅ это Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎ.
ΠšΡ€ΠΎΠΌΠ΅ Ρ‚ΠΎΠ³ΠΎ, ΠΌΠΎΠ³ΡƒΡ‚ ΠΏΡ€ΠΈΠΌΠ΅Π½ΡΡ‚ΡŒΡΡ Π½Π°Ρ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹Π΅ Π½ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½Ρ‹Π΅ Π΄ΠΎΠΊΡƒΠΌΠ΅Π½Ρ‚Ρ‹.
vi Β© ISO 2007 – ВсС ΠΏΡ€Π°Π²Π° ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ

ΠœΠ•Π–Π”Π£ΠΠΠ ΠžΠ”ΠΠ«Π™ БВАНДАРВ ISO 17593:2007(R)

ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½Ρ‹Π΅ исслСдования ΠΈ in vitro
мСдицинскиС устройства. ВрСбования ΠΊ in vitro систСмам
контроля для самоконтроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагулянтной
Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ
1 ΠžΠ±Π»Π°ΡΡ‚ΡŒ примСнСния
Π”Π°Π½Π½Ρ‹ΠΉ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹ΠΉ стандарт опрСдСляСт трСбования ΠΊ in vitro систСмам измСрСния для
самоконтроля Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ, ΠΏΡ€ΠΎΡ‚ΠΈΠ²ΠΎΠ΄Π΅ΠΉΡΡ‚Π²ΡƒΡŽΡ‰Π΅ΠΉ Π²ΠΈΡ‚Π°ΠΌΠΈΠ½Ρƒ К, Π²ΠΊΠ»ΡŽΡ‡Π°Ρ Ρ€Π°Π±ΠΎΡ‡ΠΈΠ΅ характСристики, Π³Π°Ρ€Π°Π½Ρ‚ΠΈΡŽ
качСства ΠΈ ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΡƒ ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Π΅ΠΉ ΠΈ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΡƒ Π²Π΅Ρ€ΠΈΡ„ΠΈΠΊΠ°Ρ†ΠΈΠΈ ΠΈ Π²Π°Π»ΠΈΠ΄Π°Ρ†ΠΈΠΈ функционирования
ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Π½Ρ‹ΠΌΠΈ ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡΠΌΠΈ ΠΏΡ€ΠΈ Π΄Π΅ΠΉΡΡ‚Π²ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… ΠΈ искусствСнных условиях примСнСния.
Π”Π°Π½Π½Ρ‹ΠΉ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹ΠΉ стандарт относится ΠΈΡΠΊΠ»ΡŽΡ‡ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ ΠΊ систСмам измСрСния ΠΏΡ€ΠΎΡ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½ΠΎΠ²ΠΎΠ³ΠΎ
Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅ΠΌΡ‹ΠΌ ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡΠΌΠΈ для контроля ΠΈΡ… собствСнной Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ, ΠΏΡ€ΠΎΡ‚ΠΈΠ²ΠΎΠ΄Π΅ΠΉΡΡ‚Π²ΡƒΡŽΡ‰Π΅ΠΉ
Π²ΠΈΡ‚Π°ΠΌΠΈΠ½Ρƒ K, ΠΈ ΠΏΡ€Π΅Π΄ΡΡ‚Π°Π²Π»ΡΡŽΡ‰ΠΈΠΌ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ ΠΊΠ°ΠΊ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Π΅ Π½ΠΎΡ€ΠΌΠΈΡ€ΠΎΠ²Π°Π½Π½Ρ‹Π΅ ΡΠΎΠΎΡ‚Π½ΠΎΡˆΠ΅Π½ΠΈΡ
(international normalized ratios, INR).
Π”Π°Π½Π½Ρ‹ΠΉ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹ΠΉ стандарт ΠΏΠΎΠ΄Ρ…ΠΎΠ΄ΠΈΡ‚ для ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΉ Ρ‚Π°ΠΊΠΈΡ… систСм ΠΈ Π΄Ρ€ΡƒΠ³ΠΈΡ… ΠΎΡ€Π³Π°Π½ΠΈΠ·Π°Ρ†ΠΈΠΉ
(Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΠΈΡ€ΡƒΡŽΡ‰ΠΈΠ΅ ΠΎΡ€Π³Π°Π½Ρ‹ ΠΈ ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‰ΠΈΠ΅ ΠΎΡ†Π΅Π½ΠΎΡ‡Π½Ρ‹Π΅ ΠΎΡ€Π³Π°Π½ΠΈΠ·Π°Ρ†ΠΈΠΈ), отвСтствСнных Π·Π°
ΠΎΡ†Π΅Π½ΠΊΡƒ функционирования Ρ‚Π°ΠΊΠΈΡ… систСм.
Π”Π°Π½Π½Ρ‹ΠΉ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹ΠΉ стандарт Π½Π΅
⎯ ΠΈΠΌΠ΅Π΅Ρ‚ ΠΎΡ‚Π½ΠΎΡˆΠ΅Π½ΠΈΡ ΠΊ in vitro систСмам измСрСния для количСствСнной ΠΎΡ†Π΅Π½ΠΊΠΈ коагуляции Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ,
ΠΏΡ€ΠΎΡ‚ΠΈΠ²ΠΎΠ΄Π΅ΠΉΡΡ‚Π²ΡƒΡŽΡ‰Π΅ΠΉ Π²ΠΈΡ‚Π°ΠΌΠΈΠ½Ρƒ K, примСняСмой Π²Ρ€Π°Ρ‡Π°ΠΌΠΈ ΠΈΠ»ΠΈ поставщиками Π² области
здравоохранСния,
⎯ прСдусматриваСт всСстороннСй ΠΎΡ†Π΅Π½ΠΊΠΈ всСх Π²ΠΎΠ·ΠΌΠΎΠΆΠ½Ρ‹Ρ… Ρ„Π°ΠΊΡ‚ΠΎΡ€ΠΎΠ², ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ ΠΌΠΎΠ³ΡƒΡ‚ Π΄Π΅ΠΉΡΡ‚Π²ΠΎΠ²Π°Ρ‚ΡŒ Π½Π°
Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½ΠΈΡ€ΠΎΠ²Π°Π½ΠΈΠ΅ этих систСм, ΠΈΠ»ΠΈ
⎯ ΠΎΠ±Ρ€Π°Ρ‰Π°Π΅Ρ‚ внимания Π½Π° мСдицинскиС аспСкты ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляционной Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ.
2 НормативныС ссылки
Бсылка Π½Π° ΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠ΅ Π΄ΠΎΠΊΡƒΠΌΠ΅Π½Ρ‚Ρ‹ ΠΎΠ±ΡΠ·Π°Ρ‚Π΅Π»ΡŒΠ½Π° ΠΏΡ€ΠΈ использовании Π΄Π°Π½Π½ΠΎΠ³ΠΎ Π΄ΠΎΠΊΡƒΠΌΠ΅Π½Ρ‚Π°. Для ТСстких
ссылок ΠΏΡ€ΠΈΠΌΠ΅Π½ΡΡŽΡ‚ΡΡ Ρ‚ΠΎΠ»ΡŒΠΊΠΎ ΡƒΠΊΠ°Π·Π°Π½Π½ΠΎΠ΅ ΠΏΠΎ тСксту ΠΈΠ·Π΄Π°Π½ΠΈΠ΅. Для ΠΏΠ»Π°Π²Π°ΡŽΡ‰ΠΈΡ… ссылок Π½Π΅ΠΎΠ±Ρ…ΠΎΠ΄ΠΈΠΌΠΎ
ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚ΡŒ самоС послСднСС ΠΈΠ·Π΄Π°Π½ΠΈΠ΅ Π½ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½ΠΎΠ³ΠΎ ссылочного Π΄ΠΎΠΊΡƒΠΌΠ΅Π½Ρ‚Π° (Π²ΠΊΠ»ΡŽΡ‡Π°Ρ Π»ΡŽΠ±Ρ‹Π΅
измСнСния).
ISO 13485, ΠœΠ΅Π΄ΠΈΡ†ΠΈΠ½ΡΠΊΠΈΠ΅ устройства. БистСмы ΠΌΠ΅Π½Π΅Π΄ΠΆΠΌΠ΅Π½Ρ‚Π° качСства. ВрСбования ΠΊ цСлям
рСгулирования
ISO 14971, ΠœΠ΅Π΄ΠΈΡ†ΠΈΠ½ΡΠΊΠΈΠ΅ устройства. ΠŸΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ ΠΌΠ΅Π½Π΅Π΄ΠΆΠΌΠ΅Π½Ρ‚Π° риска для мСдицинских устройств
ISO 15198, ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠ°Ρ лабораторная ΠΌΠ΅Π΄ΠΈΡ†ΠΈΠ½Π°. In vitro диагностичСскиС мСдицинскиС устройства.
Валидация ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡŒΡΠΊΠΈΡ… ΠΏΡ€ΠΎΡ†Π΅Π΄ΡƒΡ€ контроля качСства ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ
ISO 17511, In vitro диагностичСскиС мСдицинскиС устройства. Π˜Π·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅ количСства Π²
биологичСских ΠΎΠ±Ρ€Π°Π·Ρ†Π°Ρ…. ΠœΠ΅Ρ‚Ρ€ΠΎΠ»ΠΎΠ³ΠΈΡ‡Π΅ΡΠΊΠΎΠ΅ Сдинство ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ Π²Π΅Π»ΠΈΡ‡ΠΈΠ½, установлСнных для
ΠΊΠ°Π»ΠΈΠ±Ρ€Π°Ρ‚ΠΎΡ€ΠΎΠ² ΠΈ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹Ρ… ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»ΠΎΠ²
1)
ISO 18113-1:β€” , ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½Ρ‹Π΅ исслСдования ΠΈ in vitro диагностичСскиС мСдицинскиС
систСмы. Π˜Π½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡ, прСдоставляСмая ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ (ΠΌΠ°Ρ€ΠΊΠΈΡ€ΠΎΠ²ΠΊΠ°). Π§Π°ΡΡ‚ΡŒ 1. Π’Π΅Ρ€ΠΌΠΈΠ½Ρ‹,
опрСдСлСния ΠΈ ΠΎΠ±Ρ‰ΠΈΠ΅ трСбования
1)
ISO 18113-4:β€” , ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½Ρ‹Π΅ исслСдования ΠΈ in vitro диагностичСскиС мСдицинскиС
систСмы. Π˜Π½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡ, прСдоставляСмая ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ (ΠΌΠ°Ρ€ΠΊΠΈΡ€ΠΎΠ²ΠΊΠ°). Π§Π°ΡΡ‚ΡŒ 4. In vitro
диагностичСскиС Ρ€Π΅Π°Π³Π΅Π½Ρ‚Ρ‹ для самоконтроля
1)
ISO 18113-5:β€” , ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½Ρ‹Π΅ исслСдования ΠΈ in vitro диагностичСскиС мСдицинскиС
систСмы. Π˜Π½Ρ„ΠΎΡ€ΠΌΠ°Ρ†ΠΈΡ, прСдоставляСмая ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ (ΠΌΠ°Ρ€ΠΊΠΈΡ€ΠΎΠ²ΠΊΠ°). Π§Π°ΡΡ‚ΡŒ 5. In vitro
диагностичСскиС инструмСнты для самоконтроля
IEC 60068-2-64:1993, ΠšΠ»ΠΈΠΌΠ°Ρ‚ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ испытания. Π§Π°ΡΡ‚ΡŒ 2. ΠœΠ΅Ρ‚ΠΎΠ΄Ρ‹ испытаний. Π˜ΡΠΏΡ‹Ρ‚Π°Π½ΠΈΠ΅ Fh:
Вибрация, ΡˆΠΈΡ€ΠΎΠΊΠΎΠΏΠΎΠ»ΠΎΡΠ½Ρ‹ΠΉ случайный Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½ (Ρ†ΠΈΡ„Ρ€ΠΎΠ²ΠΎΠ΅ ΡƒΠΏΡ€Π°Π²Π»Π΅Π½ΠΈΠ΅) ΠΈ руководство
IEC 61010-1:2001, ВрСбования Ρ‚Π΅Ρ…Π½ΠΈΠΊΠΈ бСзопасности ΠΊ элСктричСскому ΠΎΠ±ΠΎΡ€ΡƒΠ΄ΠΎΠ²Π°Π½ΠΈΡŽ для измСрСния,
контроля ΠΈ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½ΠΎΠ³ΠΎ примСнСния. Π§Π°ΡΡ‚ΡŒ 1. ΠžΠ±Ρ‰ΠΈΠ΅ трСбования
IEC 61010-2-101:2002, ВрСбования Ρ‚Π΅Ρ…Π½ΠΈΠΊΠΈ бСзопасности ΠΊ элСктричСскому ΠΎΠ±ΠΎΡ€ΡƒΠ΄ΠΎΠ²Π°Π½ΠΈΡŽ для
измСрСния, контроля ΠΈ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½ΠΎΠ³ΠΎ примСнСния. Π§Π°ΡΡ‚ΡŒ 2-101. ЧастныС трСбования ΠΊ in vitro
диагностичСскому (in vitro diagnostic, IVD) мСдицинскому ΠΎΠ±ΠΎΡ€ΡƒΠ΄ΠΎΠ²Π°Π½ΠΈΡŽ
IEC 61000-4-2, ЭлСктромагнитная ΡΠΎΠ²ΠΌΠ΅ΡΡ‚ΠΈΠΌΠΎΡΡ‚ΡŒ (Electromagnetic compatibility, EMC). Π§Π°ΡΡ‚ΡŒ 4-2.
Π˜ΡΠΏΡ‹Ρ‚Π°Ρ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ ΠΈ ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ. Π˜ΡΠΏΡ‹Ρ‚Π°Π½ΠΈΠ΅ Π·Π°Ρ‰ΠΈΡ‚Ρ‹ ΠΎΡ‚ элСктричСского разряда
IEC 61000-4-3, ЭлСктромагнитная ΡΠΎΠ²ΠΌΠ΅ΡΡ‚ΠΈΠΌΠΎΡΡ‚ΡŒ (Electromagnetic compatibility, EMC). Π§Π°ΡΡ‚ΡŒ 4-3.
Π˜ΡΠΏΡ‹Ρ‚Π°Ρ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ ΠΈ ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ. Π˜ΡΠΏΡ‹Ρ‚Π°Π½ΠΈΠ΅ Π·Π°Ρ‰ΠΈΡ‚Ρ‹ ΠΎΡ‚ ΠΈΠ·Π»ΡƒΡ‡Π°Π΅ΠΌΠΎΠ³ΠΎ,
высокочастотного элСктромагнитного поля
IEC 61326, ЭлСктричСскоС ΠΎΠ±ΠΎΡ€ΡƒΠ΄ΠΎΠ²Π°Π½ΠΈΠ΅ для измСрСния, контроля ΠΈ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½ΠΎΠ³ΠΎ примСнСния.
ВрСбования ΠΊ элСктромагнитной совмСстимости (Electromagnetic compatibility, EMC)
EN 13532:2002, ΠžΠ±Ρ‰ΠΈΠ΅ трСбования для in vitro диагностичСских мСдицинских устройств для
самоконтроля
EN 13612, ΠžΡ†Π΅Π½ΠΊΠ° ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ in vitro диагностичСских мСдицинских устройств
EN 13640, ИсслСдованиС устойчивости in vitro диагностичСских Ρ€Π΅Π°Π³Π΅Π½Ρ‚ΠΎΠ²
БСрия тСхничСских ΠΎΡ‚Ρ‡Π΅Ρ‚ΠΎΠ² WHO, No. 889, 1999, ΠŸΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ 3. Π Π΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°Ρ†ΠΈΠΈ для тромбопластин ΠΈ
ΠΏΠ»Π°Π·ΠΌΠ΅, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅ΠΌΡ‹ΠΌ для контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляционной Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ
3 Π’Π΅Ρ€ΠΌΠΈΠ½Ρ‹ ΠΈ опрСдСлСния
Π’ Ρ€Π°ΠΌΠΊΠ°Ρ… Π΄Π°Π½Π½ΠΎΠ³ΠΎ Π΄ΠΎΠΊΡƒΠΌΠ΅Π½Ρ‚Π° ΠΏΡ€ΠΈΠΌΠ΅Π½ΡΡŽΡ‚ΡΡ Ρ‚Π΅Ρ€ΠΌΠΈΠ½Ρ‹ ΠΈ опрСдСлСния ISO 18113-1 ΠΈ ΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠ΅.
3.1
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ измСрСния
accuracy of measurement
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ соотвСтствия ΠΌΠ΅ΠΆΠ΄Ρƒ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠΌ измСрСния ΠΈ общСпринятым эталонным Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ΠΌ

1) ΠžΠΏΡƒΠ±Π»ΠΈΠΊΠΎΠ²Π°Π½ΠΎ.
2 Β© ISO 2007 – ВсС ΠΏΡ€Π°Π²Π° ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ

ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Π’Π΅Ρ€ΠΌΠΈΠ½ β€œΡ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ измСрСния”, ΠΊΠΎΠ³Π΄Π° ΠΎΠ½ примСняСтся ΠΊ установлСнным Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Π°ΠΌ измСрСния,
Π²ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ Π² сСбя сочСтаниС случайных ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚ΠΎΠ² ΠΈ ΠΎΠ±Ρ‰Π΅ΠΉ систСматичСской ошибки ΠΈΠ»ΠΈ составной части
систСматичСской ошибки. (VIM:1993)
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Для систСм контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ измСряСтся ΡΡ‚Π΅ΠΏΠ΅Π½ΡŒΡŽ совпадСния
ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ ΠΎΠ±Ρ€Π°Π·Ρ†ΠΎΠ² ΠΊΡ€ΠΎΠ²ΠΈ ΠΎΡ‚ Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² с INR значСниями, ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½Ρ‹ΠΌΠΈ для ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Ρ…
эталонных (International Reference Preparation, IRP) тромбопластин.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 3 Адаптировано ΠΈΠ· ISO 3534-1:2006, 3.11.
3.2
систСматичСская ошибка измСрСния
bias of measurement
Ρ€Π°Π·Π½ΠΎΡΡ‚ΡŒ ΠΌΠ΅ΠΆΠ΄Ρƒ матСматичСским ΠΎΠΆΠΈΠ΄Π°Π½ΠΈΠ΅ΠΌ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² измСрСния ΠΈ общСпринятым эталонным Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ΠΌ
[ISO 5725-1:1994, 3.8]
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Π‘истСматичСская ошибка являСтся ΠΌΠ΅Ρ€ΠΎΠΉ точности. [VIM:1993]
3.3
ΠΊΡ€ΠΎΠ²ΡŒ
blood
Ρ†ΠΈΡ€ΠΊΡƒΠ»ΠΈΡ€ΡƒΡŽΡ‰Π°Ρ внутрисосудистая Ρ‚ΠΊΠ°Π½ΡŒ Ρ‚Π΅Π»Π°, состоящая ΠΈΠ· Π²Π·Π²Π΅ΡˆΠ΅Π½Π½Ρ‹Ρ… Ρ„ΠΎΡ€ΠΌΠ΅Π½Π½Ρ‹Ρ… элСмСнтов ΠΈ
ΠΆΠΈΠ΄ΠΊΠΎΠΉ ΠΏΠ»Π°Π·ΠΌΡ‹
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Π’ Π΄Π°Π½Π½ΠΎΠΌ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠΌ стандартС Ρ‚Π΅Ρ€ΠΌΠΈΠ½ относятся ΠΊ чистой, Π½Π΅ΠΊΠΎΠ°Π³ΡƒΠ»ΠΈΡ€ΠΎΠ²Π°Π½Π½ΠΎΠΉ ΠΊΡ€ΠΎΠ²ΠΈ.
3.4
ΠΎΠ±Ρ€Π°Π·Π΅Ρ† капиллярной ΠΊΡ€ΠΎΠ²ΠΈ
capillary blood sample
ΠΊΡ€ΠΎΠ²ΡŒ, собранная послС ΠΏΡ€ΠΎΠΊΠΎΠ»Π° ΠΌΠ΅Π»ΠΊΠΈΡ… сосудов, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ ΡΠΎΠ΅Π΄ΠΈΠ½ΡΡŽΡ‚ Π°Ρ€Ρ‚Π΅Ρ€ΠΈΠΈ ΠΈ Π²Π΅Π½Ρ‹
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Часто получаСтся с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ ΠΏΡ€ΠΎΠΊΠΎΠ»Π° ΠΏΠ°Π»ΡŒΡ†Π°; капиллярная ΠΊΡ€ΠΎΠ²ΡŒ ΠΎΠ±Ρ‹Ρ‡Π½ΠΎ собираСтся Π±Π΅Π·
Π΄ΠΎΠ±Π°Π²ΠΎΠΊ, Ρ‚Π°ΠΊΠΈΡ… ΠΊΠ°ΠΊ антикоагулянты ΠΈΠ»ΠΈ Π°Π½Ρ‚ΠΈΡ„Π΅Ρ€ΠΌΠ΅Π½Ρ‚Π°Ρ‚ΠΎΡ€Ρ‹. ΠŸΠΎΡΡ‚ΠΎΠΌΡƒ ΠΎΠ½Π°, ΠΏΠΎ сути, являСтся Π½Π΅ΡΡ‚Π°Π±ΠΈΠ»ΡŒΠ½ΠΎΠΉ.
3.5
ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹ΠΉ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»
control material
вСщСство, ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π» ΠΈΠ»ΠΈ ΠΈΠ·Π΄Π΅Π»ΠΈΠ΅, ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Π½ΠΎΠ΅ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ для примСнСния ΠΏΡ€ΠΈ ΠΏΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ΅
Ρ€Π°Π±ΠΎΡ‡ΠΈΡ… характСристик in vitro диагностичСского мСдицинского устройства
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Адаптировано ΠΈΠ· EN 375:2001, 3.5.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹Π΅ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»Ρ‹ для контроля антикоагуляции ΠΌΠΎΠ³ΡƒΡ‚ Π±Ρ‹Ρ‚ΡŒ химичСски Π°ΠΊΡ‚ΠΈΠ²Π½Ρ‹ΠΌΠΈ ΠΈ
Π½Π΅Π°ΠΊΡ‚ΠΈΠ²Π½Ρ‹ΠΌΠΈ. Π₯имичСски Π°ΠΊΡ‚ΠΈΠ²Π½Ρ‹ΠΉ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π» вступаСт Π² Ρ€Π΅Π°ΠΊΡ†ΠΈΡŽ с ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚Π°ΠΌΠΈ Ρ€Π΅Π°Π³Π΅Π½Ρ‚ΠΎΠ². НСактивный
ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹ΠΉ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π» Π½Π΅ вступаСт Π² Ρ€Π΅Π°ΠΊΡ†ΠΈΡŽ с ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚Π°ΠΌΠΈ Ρ€Π΅Π°Π³Π΅Π½Ρ‚ΠΎΠ², Π½ΠΎ ΠΌΠΎΠΆΠ΅Ρ‚ ΠΎΠ±Π΅ΡΠΏΠ΅Ρ‡ΠΈΠ²Π°Ρ‚ΡŒ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ
функционирования Ρ‡Π΅Ρ€Π΅Π· Π΄Ρ€ΡƒΠ³ΠΈΠ΅ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ, Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, имитация Ρ€Π΅Π°ΠΊΡ†ΠΈΠΈ (см. физичСский ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ).
3.6
ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹ΠΉ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π»
control interval
статистичСски обоснованноС Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅, ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½ΠΎΠ΅ ΠΊΠ°ΠΊ ΠΏΡ€ΠΈΠ΅ΠΌΠ»Π΅ΠΌΠΎΠ΅ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½Π½ΠΎΠ΅ Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅,
ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½ΠΎΠ΅, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΡ Π·Π°Π΄Π°Π½Π½Ρ‹ΠΉ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹ΠΉ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»
3.7
поставщик Π² области здравоохранСния
healthcare provider
ΡΡƒΠ±ΡŠΠ΅ΠΊΡ‚, ΡƒΠΏΠΎΠ»Π½ΠΎΠΌΠΎΡ‡Π΅Π½Π½Ρ‹ΠΉ ΠΎΠΊΠ°Π·Ρ‹Π²Π°Ρ‚ΡŒ ΠΌΠ΅Π΄ΠΈΡ†ΠΈΠ½ΡΠΊΡƒΡŽ ΠΏΠΎΠΌΠΎΡ‰ΡŒ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Ρƒ
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Π’ Π΄Π°Π½Π½ΠΎΠΌ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠΌ стандартС поставщиком Π² области здравоохранСния являСтся
ΡΡƒΠ±ΡŠΠ΅ΠΊΡ‚, Ρ‚Π°ΠΊΠΎΠΉ ΠΊΠ°ΠΊ Π΄ΠΎΠΊΡ‚ΠΎΡ€, мСдицинская сСстра, Ρ‚Π΅Ρ…Π½ΠΈΠΊ, тСхничСский спСциалист ΠΈΠ»ΠΈ ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‰ΠΈΠΉ ассистСнт,
ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΉ прСдоставляСт ΠΈΠ½ΡΡ‚Ρ€ΡƒΠΊΡ†ΠΈΡŽ ΠΏΠΎ ΡΠ°ΠΌΠΎΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŽ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Π°.
3.8
комплСксный Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹ΠΉ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ
integrated functional control
ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹ΠΉ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π», свойствСнный ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚Ρƒ Ρ€Π΅Π°Π³Π΅Π½Ρ‚Π° ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ систСмы,
прСдусмотрСнный ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ для контроля функционирования ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ систСмы
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• ΠšΠΎΠΌΠΏΠ»Π΅ΠΊΡΠ½Ρ‹ΠΉ Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹ΠΉ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ запускаСтся ΠΎΠ΄Π½ΠΎΠ²Ρ€Π΅ΠΌΠ΅Π½Π½ΠΎ с ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅ΠΌ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Π°,
содСрТащим Π² сСбС химичСски Π°ΠΊΡ‚ΠΈΠ²Π½Ρ‹ΠΉ ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚, ΠΈ обСспСчиваСт Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹ΠΉ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ
измСрСния. Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ комплСксного контроля Π΄ΠΎΠ»ΠΆΠ½Ρ‹ Π±Ρ‹Ρ‚ΡŒ Π² ΠΏΡ€Π΅Π΄Π΅Π»Π°Ρ… ΠΏΡ€Π΅Π΄ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½ΠΎΠ³ΠΎ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π»Π°
измСрСния для ΠΎΡ‚ΠΎΠ±Ρ€Π°ΠΆΠ°Π΅ΠΌΠΎΠΉ измСряСмой Π²Π΅Π»ΠΈΡ‡ΠΈΠ½Ρ‹.
3.9
ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠ΅ Π½ΠΎΡ€ΠΌΠ°Π»ΠΈΠ·ΠΎΠ²Π°Π½Π½ΠΎΠ΅ ΡΠΎΠΎΡ‚Π½ΠΎΡˆΠ΅Π½ΠΈΠ΅
international normalized ratio
INR
Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ измСрСния ΠΏΡ€ΠΎΡ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½ΠΎΠ²ΠΎΠ³ΠΎ Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Π°, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΉ Π±Ρ‹Π» стандартизован ΠΏΠΎ
эффСктивности тромбопластин, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅ΠΌΡ‹Ρ… Π² процСссС измСрСния ΠΈ Π²Ρ‹Ρ€Π°ΠΆΠ΅Π½ ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ
Π½ΠΎΡ€ΠΌΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ срСднСго ΠΏΠΎ совокупности
[30]
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Для обсуТдСния примСнСния INR, см. Poller, et al. .
3.10
ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹ΠΉ эталонный ΠΏΡ€Π΅ΠΏΠ°Ρ€Π°Ρ‚
international reference preparation
IRP
эталонный ΠΊΠ°Π»ΠΈΠ±Ρ€Π°Ρ‚ΠΎΡ€, установлСнный всСмирной ΠΎΡ€Π³Π°Π½ΠΈΠ·Π°Ρ†ΠΈΠ΅ΠΉ здравоохранСния
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• IRP для тромбопластин ΠΎΡ‚ΠΊΠ°Π»ΠΈΠ±Ρ€ΠΎΠ²Π°Π½ нСпосрСдствСнно ΠΏΠΎ эффСктивности ΠΏΠΎ ΠΎΡ‚Π½ΠΎΡˆΠ΅Π½ΠΈΡŽ ΠΊ
ΠΎΡ€ΠΈΠ³ΠΈΠ½Π°Π»ΡŒΠ½Ρ‹ΠΌ Британским ΡΡ€Π°Π²Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΌ ΠΏΡ€Π΅ΠΏΠ°Ρ€Π°Ρ‚Π°ΠΌ тромбопластин, примСняСмым для создания INR систСм.
3.11
срСдняя ΡΡ…ΠΎΠ΄ΠΈΠΌΠΎΡΡ‚ΡŒ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ
intermediate precision of measurement
ΡΡ…ΠΎΠ΄ΠΈΠΌΠΎΡΡ‚ΡŒ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ ΠΏΡ€ΠΈ условиях срСдних ΠΌΠ΅ΠΆΠ΄Ρƒ воспроизводимыми условиями ΠΈ повторяСмыми
условиями
[5]
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 ΠŸΡ€ΠΈΠ½Ρ†ΠΈΠΏ усрСднСния ΡƒΡ€ΠΎΠ²Π½Π΅ΠΉ точности описан Π² ISO 5725-3:1994 .
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 ΠšΠΎΠ»ΠΈΡ‡Π΅ΡΡ‚Π²Π΅Π½Π½Ρ‹Π΅ ΠΏΠΎΠΊΠ°Π·Π°Ρ‚Π΅Π»ΠΈ срСднСй точности зависят ΠΎΡ‚ ΠΎΠ³ΠΎΠ²ΠΎΡ€Π΅Π½Π½Ρ‹Ρ… условий.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 3 БрСдняя Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ позволяСт ΠΏΠΎΠΊΠ°Π·Π°Ρ‚ΡŒ ΠΈΠ·ΠΌΠ΅Π½Ρ‡ΠΈΠ²ΠΎΡΡ‚ΡŒ, ΠΊΠΎΡ‚ΠΎΡ€ΡƒΡŽ Π±ΡƒΠ΄Π΅Ρ‚ ΠΈΡΠΏΡ‹Ρ‚Ρ‹Π²Π°Ρ‚ΡŒ ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡŒ Π²
процСссС ΠΎΠ±Ρ‹Ρ‡Π½ΠΎΠ³ΠΎ примСнСния.
3.12
условия срСднСй сходимости
intermediate precision conditions
условия, ΠΏΡ€ΠΈ ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ нСзависимых ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Ρ‹ ΠΎΠ΄Π½ΠΈΠΌ ΠΈ Ρ‚Π΅ΠΌ ΠΆΠ΅ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠΌ
измСрСния Π½Π° ΠΎΠ΄ΠΈΠ½Π°ΠΊΠΎΠ²Ρ‹Ρ… ΠΎΠ±Ρ€Π°Π·Ρ†Π°Ρ… Π² ΠΎΠ΄ΠΈΠ½Π°ΠΊΠΎΠ²ΠΎΠΌ располоТСнии, Π½ΠΎ ΠΏΡ€ΠΈ ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Π΄Ρ€ΡƒΠ³ΠΈΠ΅ ΠΏΠ΅Ρ€Π΅ΠΌΠ΅Π½Π½Ρ‹Π΅,
Ρ‚Π°ΠΊΠΈΠ΅ ΠΊΠ°ΠΊ ΠΎΠΏΠ΅Ρ€Π°Ρ‚ΠΎΡ€Ρ‹, ΠΎΠ±ΠΎΡ€ΡƒΠ΄ΠΎΠ²Π°Π½ΠΈΠ΅, ΠΊΠ°Π»ΠΈΠ±Ρ€ΠΎΠ²ΠΊΠ°, внСшниС условия ΠΈ/ΠΈΠ»ΠΈ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π»Ρ‹ Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ
ΠΎΡ‚Π»ΠΈΡ‡Π°ΡŽΡ‚ΡΡ
3.13
ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹ΠΉ коэффициСнт Ρ‡ΡƒΠ²ΡΡ‚Π²ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ
international sensitivity index
ISI
коэффициСнт, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΉ позволяСт ΠΏΡ€Π΅ΠΎΠ±Ρ€Π°Π·ΠΎΠ²Π°Ρ‚ΡŒ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ измСрСния ΠΏΡ€ΠΎΡ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½ΠΎΠ²ΠΎΠ³ΠΎ Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ
ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Π° Π² ΠΏΠΎΠΊΠ°Π·Π°Ρ‚Π΅Π»ΠΈ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠ³ΠΎ Π½ΠΎΡ€ΠΌΠ°Π»ΠΈΠ·ΠΎΠ²Π°Π½Π½ΠΎΠ³ΠΎ ΡΠΎΠΎΡ‚Π½ΠΎΡˆΠ΅Π½ΠΈΡ
[30]
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Для обсуТдСния примСнСния ISI ΠΈ INR, см. Poller, et al. .
4 Β© ISO 2007 – ВсС ΠΏΡ€Π°Π²Π° ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ

3.14
нСпрофСссионал
lay person
ΡΡƒΠ±ΡŠΠ΅ΠΊΡ‚ Π±Π΅Π· Ρ„ΠΎΡ€ΠΌΠ°Π»ΡŒΠ½ΠΎΠΉ ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΠΈ Π² ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‰Π΅ΠΉ сфСрС Π΄Π΅ΡΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ ΠΈΠ»ΠΈ дисциплинС
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Адаптировано ΠΈΠ· опрСдСлСния β€œΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡŒ нСпрофСссионал” Π² EN 376:2002.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Π’ Ρ€Π°ΠΌΠΊΠ°Ρ… Π΄Π°Π½Π½ΠΎΠ³ΠΎ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠ³ΠΎ стандарта нСпрофСссионалом являСтся ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡŒ
устройства контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΉ Π½Π΅ ΠΈΠΌΠ΅Π΅Ρ‚ ΡΠΏΠ΅Ρ†ΠΈΠ°Π»ΡŒΠ½Ρ‹Ρ… мСдицинских, Π½Π°ΡƒΡ‡Π½Ρ‹Ρ… ΠΈΠ»ΠΈ
тСхничСских Π·Π½Π°Π½ΠΈΠΉ, связанных с ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»Π΅ΠΌ ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции.
3.15
Ρ€Π°Π±ΠΎΡ‡ΠΈΠΉ ΠΊΠ°Π»ΠΈΠ±Ρ€Π°Ρ‚ΠΎΡ€ производитСля
стандарт Ρ€Π°Π±ΠΎΡ‡Π΅Π³ΠΎ измСрСния
manufacturer’s working calibrator
working measurement standard
стандарт, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΉ примСняСтся рСгулярно Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€ΠΈΠ΅ΠΉ производитСля для ΠΊΠ°Π»ΠΈΠ±Ρ€ΠΎΠ²ΠΊΠΈ
вСщСствСнных ΠΌΠ΅Ρ€, ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… инструмСнтов ΠΈΠ»ΠΈ эталонных ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»ΠΎΠ²
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Адаптировано ΠΈΠ· ISO 17511:2003.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Π”Π°Π½Π½Ρ‹ΠΉ стандарт примСняСтся для ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΠΈ тромбопластин, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅ΠΌΡ‹Ρ… ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ
Π² процСссС ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΠΈ смСси PT Ρ€Π΅Π°Π³Π΅Π½Ρ‚ΠΎΠ².
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 3 Π—Π°Π΄Π°Π½Π½Ρ‹ΠΉ ΠΏΠΎΠΊΠ°Π·Π°Ρ‚Π΅Π»ΡŒ Ρ€Π°Π±ΠΎΡ‡Π΅Π³ΠΎ ΠΊΠ°Π»ΠΈΠ±Ρ€Π°Ρ‚ΠΎΡ€Π° производитСля являСтся мСтрологичСски
рСгистрируСмым для IRP.
3.16
ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° измСрСния, выбранная ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ
manufacturer’s selected measurement procedure
ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° измСрСния, которая ΠΎΡ‚ΠΊΠ°Π»ΠΈΠ±Ρ€ΠΎΠ²Π°Π½Π° ΠΎΠ΄Π½ΠΈΠΌ ΠΈΠ»ΠΈ Π±ΠΎΠ»Π΅Π΅ основными ΠΈΠ»ΠΈ Π²Ρ‚ΠΎΡ€ΠΈΡ‡Π½Ρ‹ΠΌΠΈ
ΠΊΠ°Π»ΠΈΠ±Ρ€Π°Ρ‚ΠΎΡ€Π°ΠΌΠΈ ΠΈ утвСрТдСнная для ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Π½ΠΎΠ³ΠΎ примСнСния
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• ISO 17511:2003, 4.2.2 f), ΠΎΡ‚ΠΎΠ±Ρ€Π°ΠΆΠ°Π΅Ρ‚ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΡƒ, Π²Ρ‹Π±Ρ€Π°Π½Π½ΡƒΡŽ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ, Π² Π²ΠΈΠ΄Π΅
ΠΏΠΎΡΠ»Π΅Π΄ΠΎΠ²Π°Ρ‚Π΅Π»ΡŒΠ½ΠΎΠΉ Ρ†Π΅ΠΏΠΎΡ‡ΠΊΠΈ.
3.17
ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° постоянного измСрСния производитСля
manufacturer’s standing measurement procedure
ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° измСрСния, которая ΠΎΡ‚ΠΊΠ°Π»ΠΈΠ±Ρ€ΠΎΠ²Π°Π½Π° ΠΎΠ΄Π½ΠΈΠΌ ΠΈΠ»ΠΈ Π±ΠΎΠ»Π΅Π΅ Ρ€Π°Π±ΠΎΡ‡ΠΈΠΌΠΈ ΠΊΠ°Π»ΠΈΠ±Ρ€Π°Ρ‚ΠΎΡ€Π°ΠΌΠΈ
производитСля ΠΈΠ»ΠΈ Π²Ρ‹ΡΡˆΠΈΠΌΠΈ Ρ‚ΠΈΠΏΠ°ΠΌΠΈ ΠΊΠ°Π»ΠΈΠ±Ρ€Π°Ρ‚ΠΎΡ€ΠΎΠ² ΠΈ утвСрТдСнная для Π΅Π΅ ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Π½ΠΎΠ³ΠΎ
примСнСния
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• ISO 17511:2003, 4.2.2 h) ΠΎΡ‚ΠΎΠ±Ρ€Π°ΠΆΠ°Π΅Ρ‚ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΡƒ постоянного измСрСния производитСля Π² Π²ΠΈΠ΄Π΅
ΠΏΠΎΡΠ»Π΅Π΄ΠΎΠ²Π°Ρ‚Π΅Π»ΡŒΠ½ΠΎΠΉ Ρ†Π΅ΠΏΠΎΡ‡ΠΊΠΈ.
3.18
ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° измСрСния
measurement procedure
Π½Π°Π±ΠΎΡ€ ΠΎΠΏΠ΅Ρ€Π°Ρ†ΠΈΠΉ, ΡΠΏΠ΅Ρ†ΠΈΠ°Π»ΡŒΠ½ΠΎ описанных ΠΈ примСняСмых ΠΏΡ€ΠΈ Π²Ρ‹ΠΏΠΎΠ»Π½Π΅Π½ΠΈΠΈ частных Ρ‚Ρ€Π΅Π±ΠΎΠ²Π°Π½ΠΈΠΉ Π²
соотвСтствии с Π·Π°Π΄Π°Π½Π½Ρ‹ΠΌ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠΌ
[VIM:1993, 2.5]
3.19
ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΉ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π»
measuring interval
Π½Π°Π±ΠΎΡ€ Π·Π½Π°Ρ‡Π΅Π½ΠΈΠΉ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ, для ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… систСматичСская ошибка ΠΈ ΠΏΠΎΠ³Ρ€Π΅ΡˆΠ½ΠΎΡΡ‚ΡŒ Π΄ΠΎΠ»ΠΆΠ½Ρ‹ Π½Π°Ρ…ΠΎΠ΄ΠΈΡ‚ΡŒΡΡ
Π²Π½ΡƒΡ‚Ρ€ΠΈ ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½Ρ‹Ρ… ΠΏΡ€Π΅Π΄Π΅Π»ΠΎΠ²
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Π”Π°Π½Π½Ρ‹ΠΉ Ρ‚Π΅Ρ€ΠΌΠΈΠ½ ΠΎΡ‚ΠΎΠ±Ρ€Π°ΠΆΠ°Π΅Ρ‚ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π» Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² исслСдования, ΠΎΠΊΠΎΠ»ΠΎ ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠ³ΠΎ
ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ Π±Ρ‹Π»ΠΈ ΡƒΡ‚Π²Π΅Ρ€ΠΆΠ΄Π΅Π½Ρ‹ Ρ€Π°Π±ΠΎΡ‡ΠΈΠ΅ характСристики.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Адаптировано ΠΈΠ· VIM:1993, 5.4.
3.20
мСтрологичСскоС Сдинство ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ
metrological traceability
характСристика Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Π° измСрСния ΠΈΠ»ΠΈ Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ стандарта, посрСдством ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠ³ΠΎ ΠΌΠΎΠΆΠ΅Ρ‚ Π±Ρ‹Ρ‚ΡŒ
ΠΎΡ€Π³Π°Π½ΠΈΠ·ΠΎΠ²Π°Π½Π° установлСнная связь, ΠΎΠ±Ρ‹Ρ‡Π½ΠΎ Π½Π°Ρ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹Π΅ ΠΈΠ»ΠΈ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹Π΅ стандарты, Ρ‡Π΅Ρ€Π΅Π·
Π½Π΅ΠΏΡ€Π΅Ρ€Ρ‹Π²Π½ΡƒΡŽ Ρ†Π΅ΠΏΠΎΡ‡ΠΊΡƒ сопоставлСний всСх ΠΈΠΌΠ΅ΡŽΡ‰ΠΈΡ…ΡΡ установлСнных ΠΏΠΎΠ³Ρ€Π΅ΡˆΠ½ΠΎΡΡ‚Π΅ΠΉ
[VIM:1993, 6.10]
3.21
систСма физичСского контроля
physical control system
ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΠΈΠΈΡ€ΡƒΡŽΡ‰Π΅Π΅ устройство, ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠ΅ Π½Π΅ содСрТит химичСски Π°ΠΊΡ‚ΠΈΠ²Π½Ρ‹Ρ… ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚ΠΎΠ² ΠΈ ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠ΅
ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½ΠΎ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»Π΅ΠΌ для Π²Π΅Ρ€ΠΈΡ„ΠΈΠΊΠ°Ρ†ΠΈΠΈ функционирования инструмСнта
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 БистСма физичСского контроля ΠΌΠΎΠΆΠ΅Ρ‚ Π±Ρ‹Ρ‚ΡŒ прСдставлСна Π² Ρ„ΠΎΡ€ΠΌΠ΅ элСктронного устройства,
ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠ΅ обСспСчиваСт ΠΈΠΌΠΈΡ‚Π°Ρ†ΠΈΡŽ Ρ€Π΅Π°ΠΊΡ†ΠΈΠΈ.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ физичСского контроля Π΄ΠΎΠ»ΠΆΠ½Ρ‹ Π±Ρ‹Ρ‚ΡŒ Π²Π½ΡƒΡ‚Ρ€ΠΈ прСдписанных ΠΏΡ€Π΅Π΄Π΅Π»ΠΎΠ² для Ρ‚ΠΎΠ³ΠΎ,
Ρ‡Ρ‚ΠΎΠ±Ρ‹ ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Π°Ρ систСма ΡΡ‡ΠΈΡ‚Π°Π»Π°ΡΡŒ Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½ΠΈΡ€ΡƒΡŽΡ‰Π΅ΠΉ Π½Π°Π΄Π»Π΅ΠΆΠ°Ρ‰ΠΈΠΌ ΠΎΠ±Ρ€Π°Π·ΠΎΠΌ.
3.22
ΡΡ…ΠΎΠ΄ΠΈΠΌΠΎΡΡ‚ΡŒ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ
precision of measurement
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ соотвСтствия ΠΌΠ΅ΠΆΠ΄Ρƒ нСзависимыми Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Π°ΠΌΠΈ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ, ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½Ρ‹ΠΌΠΈ ΠΏΡ€ΠΈ ΠΎΠ³ΠΎΠ²ΠΎΡ€Π΅Π½Π½Ρ‹Ρ…
условиях
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Адаптировано ΠΈΠ· ISO 3534-2:2006.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Π£Ρ€ΠΎΠ²Π΅Π½ΡŒ точности выраТаСтся числСнно с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ статистичСских характСристик ΠΏΠΎΠ³Ρ€Π΅ΡˆΠ½ΠΎΡΡ‚ΠΈ
ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ, Ρ‚Π°ΠΊΠΈΡ… ΠΊΠ°ΠΊ срСднСквадратичСскоС ΠΎΡ‚ΠΊΠ»ΠΎΠ½Π΅Π½ΠΈΠ΅ ΠΈ коэффициСнт измСнчивости, которая связана ΠΎΠ±Ρ€Π°Ρ‚Π½ΠΎ
ΠΏΡ€ΠΎΠΏΠΎΡ€Ρ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½ΠΎ с Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒΡŽ. ΠšΠΎΠ»ΠΈΡ‡Π΅ΡΡ‚Π²Π΅Π½Π½Ρ‹Π΅ характСристики точности зависят ΠΎΡ‚ ΠΎΠ³ΠΎΠ²ΠΎΡ€Π΅Π½Π½Ρ‹Ρ… условий.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 3 Π’ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½ΠΎΠΉ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ измСрСния подраздСляСтся Π² соотвСтствии с установлСнной
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒΡŽ условий. ΠšΠΎΠ½ΠΊΡ€Π΅Ρ‚Π½Ρ‹Π΅ классы ΠΏΡ€Π΅Π΄Π΅Π»ΡŒΠ½Ρ‹Ρ… условий Π½Π°Π·Ρ‹Π²Π°ΡŽΡ‚ΡΡ β€œΠΏΠΎΠ²Ρ‚ΠΎΡ€ΡΠ΅ΠΌΠΎΡΡ‚ΡŒ" (3.26) ΠΈ
β€œΠ²ΠΎΡΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΠΌΠΎΡΡ‚ΡŒβ€ (3.28).
3.23
ΠΏΡ€ΠΎΡ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½ΠΎΠ²ΠΎΠ΅ врСмя
prothrombin time
PT
врСмя, Ρ‚Ρ€Π΅Π±ΡƒΠ΅ΠΌΠΎΠ΅ для свСртывания ΠΎΠ±Ρ€Π°Π·Ρ†Π° ΠΊΡ€ΠΎΠ²ΠΈ, ΠΏΠΎΠ΄Π²Π΅Ρ€Π³Π½ΡƒΡ‚ΠΎΠ³ΠΎ ΠΎΠ΄Π½ΠΎΠΊΡ€Π°Ρ‚Π½ΠΎΠΌΡƒ Π²ΠΎΠ·Π΄Π΅ΠΉΡΡ‚Π²ΠΈΡŽ
тромбопластины ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»Π° Ρ€Π΅Π°Π³Π΅Π½Ρ‚Π°
3.24
систСма измСрСния ΠΏΡ€ΠΎΡ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½ΠΎΠ²ΠΎΠ³ΠΎ Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ
prothrombin time measuring system
ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Π°Ρ систСма, которая рСгистрируСт врСмя, Ρ‚Ρ€Π΅Π±ΡƒΠ΅ΠΌΠΎΠ΅ ΠΎΠ±Ρ€Π°Π·Ρ†Ρƒ для свСртывания послС
воздСйствия тромбопластины ΠΈΠ»ΠΈ Ρ‚ΠΊΠ°Π½Π΅Π²ΠΎΠ³ΠΎ Ρ„Π°ΠΊΡ‚ΠΎΡ€Π° Π²Ρ‚ΠΎΡ€ΠΈΡ‡Π½ΠΎΠ³ΠΎ Ρ€Π΅Π°Π³Π΅Π½Ρ‚Π°
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• БистСма Π²ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ Π² сСбя Ρ€Π΅Π°Π³Π΅Π½Ρ‚ плюс инструмСнт, примСняСмый для рСгистрации Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ
свСртывания.
3.25
Ρ€Π΅Π°Π³Π΅Π½Ρ‚
reagent
Ρ‡Π°ΡΡ‚ΡŒ in vitro диагностичСского мСдицинского устройства, ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠ΅ Π³Π΅Π½Π΅Ρ€ΠΈΡ€ΡƒΠ΅Ρ‚ сигнал с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ
химичСской ΠΈΠ»ΠΈ элСктрохимичСской Ρ€Π΅Π°ΠΊΡ†ΠΈΠΈ, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΉ позволяСт ΠΎΠΏΡ€Π΅Π΄Π΅Π»ΡΡ‚ΡŒ количСство ΠΈ Π²Π΅Π»ΠΈΡ‡ΠΈΠ½Ρƒ,
ΠΈΠ·ΠΌΠ΅Ρ€ΡΠ΅ΠΌΡƒΡŽ Π² ΠΎΠ±Ρ€Π°Π·Ρ†Π΅
6 Β© ISO 2007 – ВсС ΠΏΡ€Π°Π²Π° ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ

3.26
ΠΏΠΎΠ²Ρ‚ΠΎΡ€ΡΠ΅ΠΌΠΎΡΡ‚ΡŒ измСрСния
repeatability of measurement
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ ΠΏΡ€ΠΈ повторяСмых условиях
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Адаптировано ΠΈΠ· ISO 3534-2:2006.
3.27
повторяСмыС условия
repeatability conditions
условия, ΠΏΡ€ΠΈ ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ нСзависимых ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Ρ‹ ΠΎΠ΄Π½ΠΈΠΌ ΠΈ Ρ‚Π΅ΠΌ ΠΆΠ΅ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠΌ
измСрСния Π½Π° ΠΈΠ΄Π΅Π½Ρ‚ΠΈΡ‡Π½Ρ‹Ρ… ΠΎΠ±Ρ€Π°Π·Ρ†Π°Ρ… Π² ΠΎΠ΄Π½ΠΎΠΉ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€ΠΈΠΈ ΠΎΠ΄Π½ΠΈΠΌ ΠΎΠΏΠ΅Ρ€Π°Ρ‚ΠΎΡ€ΠΎΠΌ, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΡ ΠΎΠ΄ΠΈΠ½Π°ΠΊΠΎΠ²ΠΎΠ΅
ΠΎΠ±ΠΎΡ€ΡƒΠ΄ΠΎΠ²Π°Π½ΠΈΠ΅ Π² ΠΊΠΎΡ€ΠΎΡ‚ΠΊΠΈΠ΅ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π»Ρ‹ Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Адаптировано ΠΈΠ· ISO 3534-2:2006.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 ΠΠ΅ΠΈΠ·ΠΌΠ΅Π½Π½Ρ‹Π΅ ΠΏΠΎ сущСству условия ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Ρ‹ для прСдставлСния условий, приводящих ΠΊ
минимальной измСнчивости Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 3 Π’ Ρ€Π°ΠΌΠΊΠ°Ρ… Π΄Π°Π½Π½ΠΎΠ³ΠΎ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠ³ΠΎ стандарта, β€œΠ»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€ΠΈΠΈβ€ Π΄ΠΎΠ»ΠΆΠ½Ρ‹ Π²ΠΎΡΠΏΡ€ΠΈΠ½ΠΈΠΌΠ°Ρ‚ΡŒΡΡ ΠΊΠ°ΠΊ
β€œΠΌΠ΅ΡΡ‚ΠΎΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅β€.
3.28
Π²ΠΎΡΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΠΌΠΎΡΡ‚ΡŒ измСрСния
reproducibility of measurement
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ измСрСния ΠΏΡ€ΠΈ воспроизводимых условиях
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Адаптировано ΠΈΠ· ISO 3534-2:2006.
3.29
воспроизводимыС условия
reproducibility conditions
условия, ΠΏΡ€ΠΈ ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ измСрСния ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Ρ‹ ΠΎΠ΄Π½ΠΈΠΌ ΠΈ Ρ‚Π΅ΠΌ ΠΆΠ΅ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΎΠΌ измСрСния Π½Π°
ΠΈΠ΄Π΅Π½Ρ‚ΠΈΡ‡Π½Ρ‹Ρ… ΠΎΠ±Ρ€Π°Π·Ρ†Π°Ρ… Π² Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… лабораториях Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹ΠΌΠΈ ΠΎΠΏΠ΅Ρ€Π°Ρ‚ΠΎΡ€Π°ΠΌΠΈ, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΡ Ρ€Π°Π·Π»ΠΈΡ‡Π½ΠΎΠ΅
ΠΎΠ±ΠΎΡ€ΡƒΠ΄ΠΎΠ²Π°Π½ΠΈΠ΅
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 ΠŸΠΎΠ»Π½ΠΎΡΡ‚ΡŒΡŽ ΠΈΠ·ΠΌΠ΅Π½Π΅Π½Π½Ρ‹Π΅ условия ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Ρ‹ для прСдставлСния условий, приводящих ΠΊ
максимальной измСнчивости Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² испытания.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Π’ Ρ€Π°ΠΌΠΊΠ°Ρ… Π΄Π°Π½Π½ΠΎΠ³ΠΎ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½ΠΎΠ³ΠΎ стандарта, β€œΠ»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€ΠΈΠΈβ€ Π΄ΠΎΠ»ΠΆΠ½Ρ‹ Π²ΠΎΡΠΏΡ€ΠΈΠ½ΠΈΠΌΠ°Ρ‚ΡŒΡΡ ΠΊΠ°ΠΊ
β€œΠΌΠ΅ΡΡ‚ΠΎΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅β€.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 3 Адаптировано ΠΈΠ· ISO 3534-2:2006.
3.30
Π²Ρ‚ΠΎΡ€ΠΈΡ‡Π½Ρ‹ΠΉ эталон ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ измСрСния
secondary reference measurement procedure
ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° измСрСния, которая ΠΎΡ‚ΠΊΠ°Π»ΠΈΠ±Ρ€ΠΎΠ²Π°Π½Π° с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ»ΠΈ Π±ΠΎΠ»Π΅Π΅ основных ΠΊΠ°Π»ΠΈΠ±Ρ€Π°Ρ‚ΠΎΡ€ΠΎΠ²
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• ΠœΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° измСрСния для ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ ΠΏΡ€ΠΎΡ‚Ρ€ΠΎΠΌΠ±ΠΈΠ½ΠΎΠ²ΠΎΠ³ΠΎ Π²Ρ€Π΅ΠΌΠ΅Π½ΠΈ ΠΈΠ½ΠΎΠ³Π΄Π° рассмотриваСтся ΠΊΠ°ΠΊ
β€œΠ²Ρ‚ΠΎΡ€ΠΈΡ‡Π½Π°Ρ стандартная мСтодика”.
3.31
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ систСмы
system accuracy
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ соотвСтствия Π½Π°Π±ΠΎΡ€Π° Ρ‚ΠΈΠΏΠΈΡ‡Π½Ρ‹Ρ… Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² измСрСния ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ систСмы ΠΈ ΠΈΡ…
ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‰ΠΈΡ… эталонных Π·Π½Π°Ρ‡Π΅Π½ΠΈΠΉ
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Когда Ρ‚Π΅Ρ€ΠΌΠΈΠ½ Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ измСрСния примСняСтся ΠΊ Π½Π°Π±ΠΎΡ€Ρƒ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ, ΠΎΠ½ Π²ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ Π²
сСбя сочСтаниС ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚ΠΎΠ² случайной ошибки ΠΈ ΠΎΠ±Ρ‰Π΅ΠΉ систСматичСской ошибки ΠΈΠ»ΠΈ ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚Π°
систСматичСской ошибки.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Π­Ρ‚Π°Π»ΠΎΠ½Π½Ρ‹Π΅ значСния установлСны с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ измСрСния, рСгистрируСмой для
эталонной ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ измСрСния Π²Ρ‹ΡΡˆΠ΅Π³ΠΎ порядка.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 3 Π’ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ систСмы ΠΌΠΎΠΆΠ΅Ρ‚ Π±Ρ‹Ρ‚ΡŒ прСдставлСна ΠΊΠ°ΠΊ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π», ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠΉ ΠΎΡ…Π²Π°Ρ‚Ρ‹Π²Π°Π΅Ρ‚ 95 % Ρ€Π°Π·Π»ΠΈΡ‡ΠΈΠΉ
ΠΌΠ΅ΠΆΠ΄Ρƒ вычислСнными Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Π°ΠΌΠΈ для систСмы ΠΈ ΠΈΡ… эталонными значСниями. Π”Π°Π½Π½Ρ‹ΠΉ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π» Ρ‚Π°ΠΊΠΆΠ΅ Π²ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚
Π² сСбя ΠΏΠΎΠ³Ρ€Π΅ΡˆΠ½ΠΎΡΡ‚ΡŒ измСрСния ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ измСрСния, ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΡƒΠ΅ΠΌΠΎΠΉ для опрСдСлСния эталонных Π·Π½Π°Ρ‡Π΅Π½ΠΈΠΉ.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 4 Адаптировано ΠΈΠ· ISO 15197:2003, 3.24.
3.32
ΠΈΡΡ‚ΠΈΠ½Π½ΠΎΡΡ‚ΡŒ ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ
trueness of measurement
Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ соотвСтствия ΠΌΠ΅ΠΆΠ΄Ρƒ усрСднСнным Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ΠΌ, ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½Ρ‹ΠΌ ΠΈΠ· Π±ΠΎΠ»ΡŒΡˆΠΈΡ… сСрий Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ²
ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ ΠΈ общСпринятым эталонным Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ΠΌ
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 ΠœΠ΅Ρ€ΠΎΠΉ точности являСтся систСматичСская ошибка (3.2).
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Адаптировано ΠΈΠ· ISO 3534-2:2006.
3.33
испытаниС Ρ‚ΠΈΠΏΠ°
type test
испытаниС ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ»ΠΈ Π±ΠΎΠ»Π΅Π΅ ΠΎΠ±Ρ€Π°Π·Ρ†ΠΎΠ² оборудования (ΠΈΠ»ΠΈ частСй оборудования), ΠΈΠΌΠ΅ΡŽΡ‰Π΅Π³ΠΎ особою
ΠΊΠΎΠ½ΡΡ‚Ρ€ΡƒΠΊΡ†ΠΈΡŽ, Ρ‡Ρ‚ΠΎΠ±Ρ‹ ΠΏΠΎΠΊΠ°Π·Π°Ρ‚ΡŒ ΠΏΡ€ΠΎΠ΅ΠΊΡ‚ ΠΈ конструкция ΡƒΠ΄ΠΎΠ²Π»Π΅Ρ‚Π²ΠΎΡ€ΡΡŽΡ‚ ΠΎΠ΄Π½ΠΎΠΌΡƒ ΠΈΠ»ΠΈ Π±ΠΎΠ»Π΅Π΅ трСбованиям
ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‰Π΅Π³ΠΎ стандарта
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 БтатистичСская Π²Ρ‹Π±ΠΎΡ€ΠΊΠ° Π½Π΅ трСбуСтся для Ρ‚ΠΈΠΏΠΎΠ²ΠΎΠ³ΠΎ испытания
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Адаптировано ΠΈΠ· IEC 61326:2002.
3.34
соотвСтствиС ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Ρ
user compliance
ΡƒΠΌΠ΅Π½ΠΈΠ΅ ΠΈ Π³ΠΎΡ‚ΠΎΠ²Π½ΠΎΡΡ‚ΡŒ ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Ρ ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ систСмы ΠΏΡ€ΠΈΠ΄Π΅Ρ€ΠΆΠΈΠ²Π°Ρ‚ΡŒΡΡ ΠΈ Ρ€Π°Π±ΠΎΡ‚Π°Ρ‚ΡŒ Π² Ρ€Π°ΠΌΠΊΠ°Ρ…
ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½Ρ‹Ρ… тСхничСских Ρ‚Ρ€Π΅Π±ΠΎΠ²Π°Π½ΠΈΠΉ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΈ измСрСния
3.35
ΠΎΠ±Ρ€Π°Π·Π΅Ρ† Π²Π΅Π½ΠΎΠ·Π½ΠΎΠΉ ΠΊΡ€ΠΎΠ²ΠΈ
venous blood sample
ΠΊΡ€ΠΎΠ²ΡŒ, собранная послС нСпосрСдствСнного ΠΏΡ€ΠΎΠΊΠΎΠ»Π° Π²Π΅Π½Ρ‹, ΠΎΠ±Ρ‹Ρ‡Π½ΠΎ с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ ΠΈΠ³Π»Ρ‹ ΠΈ ΡˆΠΏΡ€ΠΈΡ†Π° ΠΈΠ»ΠΈ
Π΄Ρ€ΡƒΠ³ΠΈΠΌ устройством Π·Π°Π±ΠΎΡ€Π° ΠΊΡ€ΠΎΠ²ΠΈ
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• ВСнозная ΠΊΡ€ΠΎΠ²ΡŒ ΠΌΠΎΠΆΠ΅Ρ‚ Π±Ρ‹Ρ‚ΡŒ собрана Π±Π΅Π· Π΄ΠΎΠ±Π°Π²ΠΎΠΊ, Ρ‚Π°ΠΊΠΈΡ… ΠΊΠ°ΠΊ антикоагулянты ΠΈΠ»ΠΈ консСрванты, ΠΈ
Ρ‚Π°ΠΊΠΈΠΌ ΠΎΠ±Ρ€Π°Π·ΠΎΠΌ, ΠΏΠΎ сути, Π±ΡƒΠ΄Π΅Ρ‚ Π½Π΅ΡΡ‚Π°Π±ΠΈΠ»ΡŒΠ½ΠΎΠΉ; вСнозная ΠΊΡ€ΠΎΠ²ΡŒ Ρ‚Π°ΠΊΠΆΠ΅ ΠΌΠΎΠΆΠ΅Ρ‚ Π±Ρ‹Ρ‚ΡŒ собрана Π² ΠΊΠΎΠ½Ρ‚Π΅ΠΉΠ½Π΅Ρ€Ρ‹,
содСрТащиС Π΄ΠΎΠ±Π°Π²ΠΊΠΈ ΠΈ консСрванты, ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Π½Ρ‹Π΅ для стабилизации ΡΠΏΠ΅Ρ†ΠΈΠ°Π»ΡŒΠ½Ρ‹Ρ… ΠΊΠΎΠΌΠΏΠΎΠ½Π΅Π½Ρ‚ΠΎΠ².
3.36
объСмная доля эритроцитов Π² ΠΊΡ€ΠΎΠ²ΠΈ
volume fraction of erythrocytes in blood
ΡΠΎΠΎΡ‚Π½ΠΎΡˆΠ΅Π½ΠΈΠ΅ ΡƒΠΏΠ»ΠΎΡ‚Π½Π΅Π½Π½Ρ‹Ρ… ΠΊΠ»Π΅Ρ‚ΠΎΠΊ Π² ΠΎΠ±Ρ€Π°Π·Ρ†Π΅ ΠΊΡ€ΠΎΠ²ΠΈ
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Π’ыраТаСтся Π»ΠΈΠ±ΠΎ ΠΊΠ°ΠΊ фракция, часто задаСтся ΠΊΠ°ΠΊ ΠΏΡ€ΠΎΡ†Π΅Π½Ρ‚ (условный) Π² Π΅Π΄ΠΈΠ½ΠΈΡ†Π°Ρ… БИ.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Π˜Π½ΠΎΠ³Π΄Π° называСтся β€œΠ³Π΅ΠΌΠ°Ρ‚ΠΎΠΊΡ€ΠΈΡ‚β€, благодаря инструмСнту ΠΏΠ΅Ρ€Π²ΠΎΠ½Π°Ρ‡Π°Π»ΡŒΠ½ΠΎ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π²ΡˆΠ΅ΠΌΡƒΡΡ
для ΠΎΡ†Π΅Π½ΠΊΠΈ объСмной Ρ„Ρ€Π°ΠΊΡ†ΠΈΠΈ эритроцитов Π² ΠΊΡ€ΠΎΠ²ΠΈ.
8 Β© ISO 2007 – ВсС ΠΏΡ€Π°Π²Π° ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ

4 ΠŸΡ€ΠΎΠ΅ΠΊΡ‚ΠΈΡ€ΠΎΠ²Π°Π½ΠΈΠ΅ ΠΈ Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ°
4.1 ΠžΠ±Ρ‰ΠΈΠ΅ трСбования
ΠŸΡ€ΠΈΠΌΠ΅Π½ΡΡŽΡ‚ΡΡ трСбования, ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½Ρ‹Π΅ Π² ISO 13485.
ВрСбования, ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½Ρ‹Π΅ Π² EN 13532 ΠΏΡ€ΠΈΠΌΠ΅Π½ΡΡŽΡ‚ΡΡ для ΠΎΡ†Π΅Π½ΠΊΠΈ функционирования систСмы контроля
ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Π Π°Π·Π΄Π΅Π»Ρ‹ 6 ΠΈ 8 ΠΎΠΏΡ€Π΅Π΄Π΅Π»ΡΡŽΡ‚ Π΄Π΅ΡΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΡŒ ΠΏΠΎ ΠΏΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ΅ ΠΏΡ€Π°Π²ΠΈΠ»ΡŒΠ½ΠΎΡΡ‚ΠΈ ΠΏΡ€ΠΎΠ΅ΠΊΡ‚Π½Ρ‹Ρ… Ρ€Π΅ΡˆΠ΅Π½ΠΈΠΉ,
которая ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Π° для обСспСчСния Π³Π°Ρ€Π°Π½Ρ‚ΠΈΠΈ Ρ‚ΠΎΠ³ΠΎ, Ρ‡Ρ‚ΠΎ ΠΏΡ€ΠΎΠ΄ΡƒΠΊΡ‚ способСн ΡƒΠ΄ΠΎΠ²Π»Π΅Ρ‚Π²ΠΎΡ€ΡΡ‚ΡŒ трСбованиям ΠΏΠΎ
сходимости, истинности, бСзопасности ΠΈ надСТности. Π Π°Π·Π΄Π΅Π» 9 опрСдСляСт Π΄Π΅ΡΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΡŒ ΠΏΠΎ ΠΏΠΎΠ΄Ρ‚Π²Π΅Ρ€ΠΆΠ΄Π΅Π½ΠΈΡŽ
коррСктности конструкции, ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠ΅ ΠΏΡ€Π΅Π΄Π½Π°Π·Π½Π°Ρ‡Π΅Π½Π° для обСспСчСния Π³Π°Ρ€Π°Π½Ρ‚ΠΈΠΈ Ρ‚ΠΎΠ³ΠΎ, Ρ‡Ρ‚ΠΎ устройство удовлСтворяСт
трСбованиям ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Ρ.
4.2 Π˜Π·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΉ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π»
Π˜Π·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΉ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π» систСмы Π΄ΠΎΠ»ΠΆΠ΅Π½ Π±Ρ‹Ρ‚ΡŒ, ΠΏΠΎ мСньшСй ΠΌΠ΅Ρ€Π΅, ΠΎΡ‚ 1,0 Π΄ΠΎ 6,0 INR.
4.3 Π‘Π΅Π·ΠΎΠΏΠ°ΡΠ½ΠΎΡΡ‚ΡŒ
ΠŸΡ€ΠΈΠΌΠ΅Π½ΡΡŽΡ‚ΡΡ трСбования, ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½Ρ‹Π΅ Π² IEC 61010-1 ΠΈ IEC 61010-2-101.
4.4 Π£ΠΏΡ€Π°Π²Π»Π΅Π½ΠΈΠ΅ риском
4.4.1 Π”ΠΎΠΏΡƒΡΡ‚ΠΈΠΌΠΎΡΡ‚ΡŒ рисков
ΠŸΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒ Π΄ΠΎΠ»ΠΆΠ΅Π½ ΠΏΡ€ΠΈΠ½ΠΈΠΌΠ°Ρ‚ΡŒ Ρ€Π΅ΡˆΠ΅Π½ΠΈΠ΅ ΠΎ допустимости ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½Ρ‹Ρ… рисков Π½Π° основС Π·Π½Π°Π½ΠΈΠΉ ΠΎ
Ρ„Π°ΠΊΡ‚ΠΎΡ€Π°Ρ…, Π²ΠΊΠ»ΡŽΡ‡Π°ΡŽΡ‰ΠΈΡ…, Π½ΠΎ Π½Π΅ ΠΎΠ³Ρ€Π°Π½ΠΈΡ‡ΠΈΠ²Π°ΡŽΡ‰ΠΈΡ…ΡΡ ΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠΌΠΈ:
a) Π½Π°ΠΌΠ΅Ρ‡Π΅Π½Π½ΠΎΠ΅ ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ ΠΏΡ€ΠΎΠ΄ΡƒΠΊΡ‚Π°;
b) квалификация ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Ρ ΠΈ ограничСния:
c) Π·Π°Ρ‰ΠΈΡ‚Π° ΠΎΡ‚ Π½Π΅ΠΏΡ€Π΅Π΄Π½Π°ΠΌΠ΅Ρ€Π΅Π½Π½ΠΎΠ³ΠΎ измСнСния настроСк (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, Π΅Π΄ΠΈΠ½ΠΈΡ†Ρ‹ прСдставлСния);
d) вСроятныС отклонСния ΠΎΡ‚ Ρ€Π΅ΠΊΠΎΠΌΠ΅Π½Π΄ΠΎΠ²Π°Π½Π½ΠΎΠ³ΠΎ тСхничСского обслуТивания, ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊ Ρ€Π°Π±ΠΎΡ‚Ρ‹ ΠΈ
контроля;
e) дСйствиС ΠΌΠ΅ΡˆΠ°ΡŽΡ‰ΠΈΡ… вСщСств.
[25]
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Π Π΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°Ρ†ΠΈΠΈ ΠΏΠΎ ΠΎΡ†Π΅Π½ΠΊΠ΅ ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½ΠΎ ΠΌΠ΅ΡˆΠ°ΡŽΡ‰ΠΈΡ… вСщСств установлСны Π² CLSI Π΄ΠΎΠΊΡƒΠΌΠ΅Π½Ρ‚Π΅ EP7 .
4.4.2 ΠžΡ†Π΅Π½ΠΊΠ° риска
ΠŸΡ€ΠΈΠΌΠ΅Π½ΡΡŽΡ‚ΡΡ трСбования, ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½Ρ‹Π΅ Π² ISO 14971.
ΠŸΡ€ΠΈ Π²Ρ‹ΠΏΠΎΠ»Π½Π΅Π½ΠΈΠΈ ΠΎΡ†Π΅Π½ΠΊΠΈ риска ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒ Π΄ΠΎΠ»ΠΆΠ΅Π½ ΠΏΡ€ΠΈΠ½ΠΈΠΌΠ°Ρ‚ΡŒ Π²ΠΎ Π²Π½ΠΈΠΌΠ°Π½ΠΈΠ΅
a) Ρ‚ΡΠΆΠ΅ΡΡ‚ΡŒ послСдствий Π½Π΅ΠΎΠ±Π½Π°Ρ€ΡƒΠΆΠ΅Π½Π½ΠΎΠΉ нСисправности (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½Ρ‹ΠΉ Π²Ρ€Π΅Π΄ для
ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Π°),
b) Π²Π΅Ρ€ΠΎΡΡ‚Π½ΠΎΡΡ‚ΡŒ появлСния ошибки (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, нСдостаточный объСм ΠΎΠ±Ρ€Π°Π·Ρ†Π° ΠΈΠ»ΠΈ Π½Π΅ΠΏΡ€Π°Π²ΠΈΠ»ΡŒΠ½ΠΎΠ΅
Ρ€Π°Π·ΠΌΠ΅Ρ‰Π΅Π½ΠΈΠ΅ ΠΊΠΎΠΌΠΏΠ»Π΅ΠΊΡ‚Π° Ρ€Π΅Π°ΠΊΡ‚ΠΈΠ²ΠΎΠ²), ΠΈ
c) Π²Π΅Ρ€ΠΎΡΡ‚Π½ΠΎΡΡ‚ΡŒ ΠΎΡ‚ΠΊΠ°Π·Π° систСмы Π² ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½ΠΈΠΈ ошибки (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, Π΄Π΅Ρ„Π΅ΠΊΡ‚Π½Ρ‹Π΅ Π²Π½ΡƒΡ‚Ρ€Π΅Π½Π½ΠΈΠ΅
ΠΈΠ½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½Ρ‹Π΅ Π΄Π°Ρ‚Ρ‡ΠΈΠΊΠΈ).
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 1 Π”Π°Π½Π½Ρ‹ΠΉ ΠΌΠ΅ΠΆΠ΄ΡƒΠ½Π°Ρ€ΠΎΠ΄Π½Ρ‹ΠΉ стандарт Π½Π΅ опрСдСляСт ΡƒΡ€ΠΎΠ²Π½ΠΈ допустимости рисков.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 2 Π Π΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°Ρ†ΠΈΠΈ для опрСдСлСния ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»ΡŒΠ½Ρ‹Ρ… опасностСй ΠΎΡ‚ примСнСния β€œΠ±Π»ΠΎΠΊΠ° примСнСния
устройств” установлСны Π² CLSI Π΄ΠΎΠΊΡƒΠΌΠ΅Π½Ρ‚Π΅ EP18 [27].
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• 3 Π£ΠΏΡ€Π°Π²Π»Π΅Π½ΠΈΠ΅ риском Π²ΠΊΠ»ΡŽΡ‡Π°Π΅Ρ‚ Π² сСбя Π°Π½Π°Π»ΠΈΠ· риска, ΠΎΡ†Π΅Π½ΠΊΡƒ риска, ΡƒΠΌΠ΅Π½ΡŒΡˆΠ΅Π½ΠΈΠ΅ риска ΠΈ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ
риска.
4.5 ЭргономичСскиС аспСкты ΠΈ аспСкты чСловСчСского Ρ„Π°ΠΊΡ‚ΠΎΡ€Π°
ΠŸΡ€ΠΈ Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ΅ систСмы контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции Π΄ΠΎΠ»ΠΆΠ½Ρ‹ Π±Ρ‹Ρ‚ΡŒ приняты Π²ΠΎ Π²Π½ΠΈΠΌΠ°Π½ΠΈΠ΅
Π²Π°ΠΆΠ½Ρ‹Π΅ эргономичСский ΠΈ чСловСчСский Ρ„Π°ΠΊΡ‚ΠΎΡ€Ρ‹, Π²ΠΊΠ»ΡŽΡ‡Π°ΡŽΡ‰ΠΈΠ΅, Π½ΠΎ Π½Π΅ ΠΎΠ³Ρ€Π°Π½ΠΈΡ‡ΠΈΠ²Π°ΡŽΡ‰ΠΈΠ΅ΡΡ ΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠΌΠΈ
a) ΠŸΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡŒΡΠΊΠΈΠ΅ аспСкты:
⎯ ΠΎΡ‚Π±ΠΎΡ€;
⎯ ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΠ°;
⎯ соотвСтствиС.
b) Условия использования:
⎯ Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€Π°;
⎯ Π²Π»Π°ΠΆΠ½ΠΎΡΡ‚ΡŒ.
c) Бвойства систСмы:
⎯ ΡƒΠ΄Π°Ρ€ΠΎΠΏΡ€ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ;
⎯ ΡΡ‚Π°Π±ΠΈΠ»ΡŒΠ½ΠΎΡΡ‚ΡŒ Ρ€Π΅Π°Π³Π΅Π½Ρ‚ΠΎΠ².
d) ΠŸΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»ΡŒΡΠΊΠΈΠΉ интСрфСйс:
⎯ удобство Ρ€Π°Π±ΠΎΡ‚Ρ‹;
⎯ удобство тСхничСского обслуТивания;
⎯ Π·Π°Ρ‰ΠΈΡ‚Π° ΠΎΡ‚ ΠΎΠ±Ρ‹Ρ‡Π½ΠΎΠ³ΠΎ β€œΠΈΠ·Π½ΠΎΡΠ°β€, с ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΌ ΠΌΠΎΠΆΠ½ΠΎ ΡΡ‚ΠΎΠ»ΠΊΠ½ΡƒΡ‚ΡŒΡΡ Π² условиях использования;
⎯ ΡƒΠ΄ΠΎΠ±ΠΎΡ‡ΠΈΡ‚Π°Π΅ΠΌΠΎΡΡ‚ΡŒ прСдставлСнных Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ²;
⎯ условия ΠΎΡ‚ΠΊΠ°Π·Π° ΠΈ сообщСния ΠΎΠ± ошибкС;
⎯ ΠΎΠ΄Π½ΠΎΠ·Π½Π°Ρ‡Π½Ρ‹Π΅ сообщСния для ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Ρ (Π½Π°ΠΏΡ€ΠΈΠΌΠ΅Ρ€, β€œΠ½ΠΈΠ·ΠΊΠΈΠΉ заряд батарСи” ΠΈΠ»ΠΈ β€œΠ½ΠΈΠ·ΠΊΠΈΠΉ
Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚β€) Π»ΡƒΡ‡ΡˆΠ΅, Ρ‡Π΅ΠΌ просто β€œΠ½ΠΈΠ·ΠΊΠΈΠΉβ€;
⎯ ΠΏΡ€ΠΎΠ²Π΅Ρ€ΠΊΠ° ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Π΅ΠΌ Π½Π°Π΄Π»Π΅ΠΆΠ°Ρ‰Π΅ΠΉ Ρ€Π°Π±ΠΎΡ‚Ρ‹ систСмы.
4.6 ΠžΠ±Π΅ΡΠΏΠ΅Ρ‡Π΅Π½ΠΈΠ΅ качСства ΠΈ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ риска
4.6.1 ΠžΠ±Ρ‰ΠΈΠ΅ полоТСния
ΠžΠ±Π΅ΡΠΏΠ΅Ρ‡Π΅Π½ΠΈΠ΅ качСства систСм контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции состоит ΠΈΠ· ΠΌΠ½ΠΎΠ³ΠΈΡ… элСмСнтов.
Π‘ΠΌ. ΠŸΡ€ΠΈΠ»ΠΎΠΆΠ΅Π½ΠΈΠ΅ E для описания Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… элСмСнтов обСспСчСния качСства, ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ ΠΌΠΎΠ³ΡƒΡ‚
ΠΏΡ€ΠΈΠΌΠ΅Π½ΡΡ‚ΡŒΡΡ.
10 Β© ISO 2007 – ВсС ΠΏΡ€Π°Π²Π° ΡΠΎΡ…Ρ€Π°Π½ΡΡŽΡ‚ΡΡ

ΠŸΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒ Π΄ΠΎΠ»ΠΆΠ΅Π½ ΠΎΠ±Π΅ΡΠΏΠ΅Ρ‡ΠΈΡ‚ΡŒ ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ‹ контроля риска, зависящиС ΠΎΡ‚ устройства, Ρ‡Ρ‚ΠΎ трСбуСтся
ΠΏΠ»Π°Π½ΠΎΠΌ управлСния риском. ΠŸΡ€ΠΈΠΌΠ΅Π½ΡΡ‚ΡΡ трСбования, ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½Ρ‹Π΅ Π² ISO 14971.
ΠœΠ΅Ρ‚ΠΎΠ΄ контроля риска, Π²ΠΊΠ»ΡŽΡ‡Π°Ρ Π»ΡŽΠ±Ρ‹Π΅ ограничСния, Π΄ΠΎΠ»ΠΆΠ΅Π½ Π±Ρ‹Ρ‚ΡŒ описан Π² инструкциях ΠΏΠΎ
ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡŽ ΠΈ ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΡƒΡŽΡ‰ΠΈΡ… ΠΎΠ±ΡƒΡ‡Π°ΡŽΡ‰ΠΈΡ… ΠΏΡ€ΠΎΠ³Ρ€Π°ΠΌΠΌΠ°Ρ…, Ссли ΠΏΡ€ΠΈΠΌΠ΅Π½ΠΈΠΌΠΎ.
ΠœΠ΅Ρ‚ΠΎΠ΄ контроля риска Π΄ΠΎΠ»ΠΆΠ΅Π½ ΡƒΡ‡ΠΈΡ‚Ρ‹Π²Π°Ρ‚ΡŒ ΠΎΠ±ΡƒΡ‡Π΅Π½ΠΈΠ΅ ΠΈ ΠΏΠΎΠ΄Π³ΠΎΡ‚ΠΎΠ²ΠΊΡƒ ΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Ρ‚Π΅Π»Π΅ΠΉ ΠΈ поставщиков Π²
области здравоохранСния (см. Π Π°Π·Π΄Π΅Π» 7), Ρ‚Π°ΠΊ ΠΆΠ΅ ΠΊΠ°ΠΊ ΠΈ Π½ΠΈΠΆΠ΅ ΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠ΅ элСмСнты.
4.6.2 ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ измСрСния
КаТдоС ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠ΅, ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½ΠΎΠ΅ систСмой контроля ΠΏΠ΅Ρ€ΠΎΡ€Π°Π»ΡŒΠ½ΠΎΠΉ антикоагуляции, Π΄ΠΎΠ»ΠΆΠ½ΠΎ Π±Ρ‹Ρ‚ΡŒ
Π²Π½ΡƒΡ‚Ρ€Π΅Π½Π½Π΅ ΠΏΡ€ΠΎΠ²Π΅Ρ€Π΅Π½ΠΎ ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ систСмой.
Π₯Π°Ρ€Π°ΠΊΡ‚Π΅Ρ€ ΠΈ ΡΡ‚Π΅ΠΏΠ΅Π½ΡŒ Π²Π½ΡƒΡ‚Ρ€Π΅Π½Π½Π΅Π³ΠΎ контроля, выполняСмого ΠΈΠ·ΠΌΠ΅Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ систСмой, Π΄ΠΎΠ»ΠΆΠ½Ρ‹
ΠΎΠΏΡ€Π΅Π΄Π΅Π»ΡΡ‚ΡŒΡΡ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Π°ΠΌΠΈ Π°Π½Π°Π»ΠΈΠ·Π° стСпСни риска.
ΠŸΠ Π˜ΠœΠ•Π§ΠΠΠ˜Π• Π­Ρ‚ΠΎ ΠΎΠ·Π½Π°Ρ‡Π°Π΅Ρ‚, Ρ‡Ρ‚ΠΎ прСдотвращаСтся ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ ΡƒΡΡ‚Π°Ρ€Π΅Π²ΡˆΠΈΡ… Ρ€Π΅Π°Π³Π΅Π½Ρ‚ΠΎΠ².
4.6.3 ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ систСмы
ΠŸΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒ Π΄ΠΎΠ»ΠΆΠ΅Π½ ΠΏΡ€Π΅Π΄ΠΎΡΡ‚Π°Π²ΠΈΡ‚ΡŒ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΡƒ контроля ΠΈ ΠΈΠ½ΡΡ‚Ρ€ΡƒΠΊΡ†ΠΈΡŽ ΠΏΠΎ ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡŽ ΠΊΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹Ρ…
ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»ΠΎΠ².
Π”ΠΎΠ»ΠΆΠ½Π° Π±Ρ‹Ρ‚ΡŒ утвСрТдСнная ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠ° контроля. ΠŸΡ€ΠΈΠΌΠ΅Π½ΡΡŽΡ‚ΡΡ трСбования, ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Π½Ρ‹Π΅ Π² ISO 15198.
ΠšΠΎΠ½Ρ‚Ρ€ΠΎΠ»ΡŒΠ½Ρ‹ΠΉ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...