Industrial fans — Tolerances, methods of conversion and technical data presentation

ISO 13348:2006 specifies performance tolerances and the technical data presentation of industrial fans of all types. It does not apply for fans designed solely for low-volume air circulation, such as those used for household or similar purposes (ceiling and table fans, extractor fans, etc.). ISO 13348:2006 covers the four installation categories defined in ISO 5801:A, free inlet, free outlet; B, free inlet, ducted outlet; C, ducted inlet, free outlet;D, ducted inlet, ducted outlet.

Ventilateurs industriels — Tolérances, méthodes de conversion et présentation des données techniques

L'ISO 13348:2006 spécifie les tolérances sur les performances et la présentation des données techniques des ventilateurs industriels de tous types. Elle ne s'applique pas aux ventilateurs conçus uniquement pour le brassage de l'air, tels que ceux utilisés pour les besoins domestiques et analogues (par exemple, ventilateurs plafonniers ou de table, ventilateurs d'extraction, etc.). L'ISO 13348:2006 couvre les quatre catégories d'installation définies dans l'ISO 5801, à savoir, A: aspiration libre, refoulement libre; B: aspiration libre, refoulement en conduit; C:aspiration en conduit, refoulement libre; D: aspiration en conduit, refoulement en conduit.

General Information

Status
Withdrawn
Publication Date
27-Feb-2006
Withdrawal Date
27-Feb-2006
Technical Committee
Drafting Committee
Current Stage
9599 - Withdrawal of International Standard
Completion Date
15-Jan-2007
Ref Project

Relations

Buy Standard

Standard
ISO 13348:2006 - Industrial fans -- Tolerances, methods of conversion and technical data presentation
English language
53 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 13348:2006 - Ventilateurs industriels -- Tolérances, méthodes de conversion et présentation des données techniques
French language
55 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 13348
First edition
2006-03-01


Industrial fans — Tolerances, methods of
conversion and technical data
presentation
Ventilateurs industriels — Tolérances, méthodes de conversion et
présentation des données techniques




Reference number
ISO 13348:2006(E)
©
ISO 2006

---------------------- Page: 1 ----------------------
ISO 13348:2006(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.


©  ISO 2006
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2006 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 13348:2006(E)
Contents Page
Foreword. iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions. 2
4 Symbols and units. 6
5 Performance tolerances for purpose-designed fans . 8
5.1 Information to be provided by the purchaser . 8
5.2 Information to be provided by the supplier . 9
5.3 Tolerances . 10
5.4 Purchasing arrangements . 12
5.5 Contractual testing . 12
6 Performance tolerances for series-produced fans . 22
6.1 Tolerances in certified ratings programmes. 22
7 Methods of conversion. 27
7.1 Conversion of air performance test data. 27
7.2 Conversion of sound power test data . 34
8 Technical data presentation . 42
8.1 General. 42
8.2 Essential information . 42
8.3 Fan performance chart. 42
8.4 Additional information. 44
Annex A (normative) Documentation. 47
Annex B (normative) Marking .48
Annex C (informative) System resistance as a function of flowrate. 49
Bibliography . 52

© ISO 2006 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 13348:2006(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee has
been established has the right to be represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 13348 was prepared by Technical Committee ISO/TC 117, Industrial fans.
iv © ISO 2006 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 13348:2006(E)
Introduction
This International Standard endeavours to clarify those technical aspects of contracts where fan performance
is concerned, and the accuracy and consistency of performance details published in technical catalogues.
In this International Standard a distinction is drawn between specially designed fans to suit a specific purpose,
to meet a contract specification, and series-produced fans where the performance data is contained in a
catalogue.
For purpose-designed fans the methods of calculating performance data under contract conditions, from
performance data obtained under test conditions, are described in Clause 5 for both air and sound data. Four
tolerance grades are given, each appropriate to a particular type of fan and/or its application. These
procedures have been found satisfactory; however, the supplier and user could agree to adopt alternative
methods.
For the series-produced fans, the associated technical data will be contained in a catalogue (electronic and/or
printed form). In this case the recommended method of applying tolerances is as described in Clause 6, based
on the rules of AMCA (Air Movement and Control Association) International, Inc. for the certified ratings
[11], [12], [13]
programme . An independent accredited body, under a certified ratings programme, can be called
in to verify this data.

© ISO 2006 – All rights reserved v

---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 13348:2006(E)

Industrial fans — Tolerances, methods of conversion and
technical data presentation
1 Scope
This International Standard specifies performance tolerances and the technical data presentation of industrial
fans of all types. It does not apply for fans designed solely for low-volume air circulation, such as those used
for household or similar purposes (ceiling and table fans, extractor fans, etc.). For jet fans refer to ISO 13350.
−1
The upper limit of fan work per unit mass is normally 25 kJ kg , corresponding to an increase of fan pressure
−3
of approximately 30 kPa for a mean density in the fan of 1,2 kg m . For higher values, agreement is to be
reached between the supplier and the user.
This International Standard embraces the four installation categories defined in ISO 5801:
A free inlet, free outlet;
B free inlet, ducted outlet;
C ducted inlet, free outlet;
D ducted inlet, ducted outlet.
The performance of a fan can vary considerably with the installation category it is operating within. Therefore,
these categories form an important part of the definition of the fan’s technical data presentation.
NOTE International acceptance of the four installation categories provides the opportunity to base a contract on the
most appropriate fan category for the end user and the system designer. Correspondingly, the likelihood of the fan
providing the agreed performance, without compromise or concession, is enhanced.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 5801:1997, Industrial fans — Performance testing using standardized airways
ISO 5802, Industrial fans — Performance testing in situ
ISO 13347-1, Industrial fans — Determination of fan sound power levels under standardized laboratory
conditions — Part 1: General overview
ISO 14694, Industrial fans — Specifications for balance quality and vibration levels
ISO 14695, Industrial fans — Method of measurement of fan vibration
© ISO 2006 – All rights reserved 1

---------------------- Page: 6 ----------------------
ISO 13348:2006(E)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
NOTE In some cases, more complete definitions are to be found in ISO 5801, ISO 5802 and ISO 13349.
3.1
industrial fan
fan other than that used for household or similar purposes such as air circulation, climatization
NOTE For the purpose of this International Standard and other industrial fan standards, a household fan is defined as
having a single-phase motor operating at a maximum of 250 V and 16 A. With a sufficiently soft start, this equates to an
input power of not more than 3 kW.
3.2
series-produced fan
catalogue fan
fan whose detailed performances is widely available in a catalogue (electronic and or printed), and which is
frequently manufactured in significant quantities and available on short delivery
3.3
average stagnation pressure at a section x
p
sgx
sum of the conventional dynamic pressure, p , corrected by the Mach factor coefficient, F , at the section,
dx Mx
and the average absolute pressure, p
x
p =+pp F
sgx x dx Mx
NOTE 1 The average stagnation pressure can be calculated by
κ
κ − 1 κ −1
⎛⎞2
pp=+1 Ma
sgx x⎜⎟x
2
⎝⎠
NOTE 2 It is expressed in pascals (Pa).
3.4
average total pressure at a section x
p
tx
sum of the conventional dynamic pressure, p , corrected by the Mach factor coefficient, F , at the section,
dx Mx
and the average gauge pressure, p
ex
p=+ppF =p −p
tx ex dx Mx sgx a
NOTE 1 When the Mach number, Ma, is less than 0,122, the Mach factor, F , can be neglected
Mx
NOTE 2 See ISO 5801, ISO 5802 and 13349 for definitions.
3.5
characteristic error
flow rate change produced along the actual system characteristic by the maximum fan performance deviation
allowed by the tolerance grade selected
NOTE 1 Characteristic error is a function of the tolerance grade, the measurement uncertainty allowed, and the shape
(local slope) of the fan and actual system characteristics
NOTE 2 For the actual system characteristics, see ISO 5801.
2 © ISO 2006 – All rights reserved

---------------------- Page: 7 ----------------------
ISO 13348:2006(E)
3.6
fan aerodynamic characteristic curves
fan pressure, power, efficiency, etc., against flow rate under specified ambient conditions and at a constant
speed, or when fitted with a specified motor
3.7
fan dynamic pressure at outlet
p
d2
conventional dynamic pressure at the fan outlet calculated from the mass flow rate, the average gas density at
the outlet and the fan outlet area
2
2
⎛⎞
vq1
m2 m
p==ρ
⎜⎟
d2 2
22ρ A
22⎝⎠
NOTE It is expressed in pascals (Pa).
3.8
fan flow coefficient
ϕ
non-dimensional quantity equal to the mass flow rate divided by the product of the mean density, the
peripheral speed of the impeller and the square of the diameter of the impeller
q
m
ϕ = if Ma W 0,122
2
ρ uD
mr
q
V
ϕ = if Ma < 0,122
2
uD
r
3.9
fan outlet area
A
2
area inside the fan outlet casing flange
2
NOTE It is expressed in square metres (m ).
3.10
fan pressure
p
F
difference between the stagnation pressure at the fan outlet and the stagnation pressure at the fan inlet
p=−pp if Ma W 0,15
Fsg2 sg1
p==pp−p if Ma < 0,15
FtFt2 t1
NOTE 1 When expressing fan pressure, reference should be made to the installation category A, B, C or D.
NOTE 2 It is expressed in pascals (Pa).
© ISO 2006 – All rights reserved 3

---------------------- Page: 8 ----------------------
ISO 13348:2006(E)
3.11
fan static pressure
p
sF
conventional quantity defined as the difference between the fan pressure and the fan dynamic pressure
corrected by Mach factor F
M2
p=−ppF−p =p−p if Ma W 0,122 at the fan outlet area
sF sg2d2M2sg1 2sg1
pp=−p−p if Ma < 0,122 at the fan outlet area
sF t2 t1 d2
NOTE It is expressed in pascals (Pa).
3.12
Mach factor
F
M
correction factor applied to the dynamic pressure at a point
p − p
sg
F =
M
p
d
NOTE 1 The Mach factor can be calculated by
24 6
Ma (2−−κκ)Ma (2 )(3− 2κ)Ma
F =+1 + + + . valid for κ = 1,4
M
4 24 192
NOTE 2 It is dimensionless.
3.13
Mach number at a point
Ma
ratio of the gas velocity at a point to the velocity of sound
vv
Ma==
c
κΘR
w
where
c is the velocity of sound, cR= κΘ ;
w
R is the gas constant of humid gas.
w
NOTE It is dimensionless.
3.14
Mach number at a section x
Ma
x
average gas velocity divided by the velocity of sound at the specified airway cross-section
v
mx
Ma =
x
κΘR
wx
NOTE It is dimensionless.
4 © ISO 2006 – All rights reserved

---------------------- Page: 9 ----------------------
ISO 13348:2006(E)
3.15
optimum efficiency
η
opt
maximum efficiency achieved on the fan air characteristic with all operational parameters, except the air
system resistance, being fixed
NOTE It is expressed as a percentage.
3.16
peripheral Reynolds number
Re
u
Reynolds number based on the tip speed, u
NOTE It is dimensionless.
3.17
power coefficient
λ
non-dimensional quantity related to the impeller power using the mean fluid density at inlet
P
r
λ =
32
ρ uD
mr
3.18
pressure coefficient
ψ
non-dimensional number related to the fan pressure using the mean density of the gas and the tip speed of
the impellor
p
F
ψ =
2
ρ u
m
3.19
tip speed
u
peripheral speed of the impeller blades at their maximum diameter
−1
NOTE It is expressed in metres per second (m ⋅ s ).
3.20
total sound power level
L
W
unweighted sound power level defined as 10 times the logarithm to the base 10 of the ratio of the sound
−12
power in watts to a reference value of 10 W (1 picowatt [pW])
NOTE It is expressed in decibels (dB).
3.21
octave band sound power level
L
Wfc
sound power level in an octave band with a defined centre frequency, defined as 10 times the logarithm to the
−12
base 10 of the ratio of the sound power in watts to a reference value of 10 W (1 picowatt [pW])
NOTE It is expressed in decibels (dB).
© ISO 2006 – All rights reserved 5

---------------------- Page: 10 ----------------------
ISO 13348:2006(E)
3.22
A-weighted sound power level
L
WA
total sound power level using A-weighting
NOTE 1 See IEC 61672-1 for a definition of A-weighting.
NOTE 2 It is expressed in decibels (dB).
3.23
total sound pressure level
L
p
unweighted total sound pressure level at a specified point and under specified conditions, normally in the
octave bands with centre frequencies from 63 Hz to 8 kHz, defined as 10 times the logarithm to the base 10 of
the ratio of the square of the sound pressure to the reference value of 20 µPa
NOTE It is expressed in decibels (dB).
3.24
A-weighted sound pressure level
L

pA
total sound pressure level using A-weighting
NOTE 1 For a definition of A-weighting, see IEC 61672-1.
NOTE 2 It is expressed in decibels (dB).
3.25
tolerance zone
range of values of the specified parameters allowed, according to the applicable tolerance grade
3.26
tolerance grade
designation defining the limit deviations from the agreed or published technical performance parameters
3.27
dimensionless frequency
χ
non-dimensional logarithmic function of the ratio between the centre frequency of an octave or third-octave
band, and the rotational speed of the fan
f
c
χ = 10lg
n
4 Symbols and units
For the purposes of this docuemnt the following symbols apply:
Symbol Term Unit
2
A Fan outlet area m
2
−1
c Velocity of sound m·s
D Diameter of impeller m
r
e Uncertainty of measurement —
F Mach factor for correction of dynamic pressure at section x —

Mx
6 © ISO 2006 – All rights reserved

---------------------- Page: 11 ----------------------
ISO 13348:2006(E)
Symbol Term Unit
f Octave centre frequency Hz

c
G Index of agreed value —
2
k Parabolic constant k = ψ /ϕ —
p
L Sound pressure level dB

p
L A-weighted sound pressure level dB (A)
pA
L Sound power level dB
W
L A-weighted sound power level dB (A)
WA
L Octave band sound power level dB
Wfc
M Index of measured value —
Ma Mach number at a point —
Ma Mach number at section x —
x
−1
n Rotational speed/rotational fequency r · s
P Mechanical power supplied to the fan shaft W
a
P Shaft power of electric motor W
m
P Mechanical power required by the fan impeller W
r
p Atmospheric pressure Pa
a
p Mean gauge pressure in space and time at section x Pa
ex
p Fan pressure Pa
F
p Fan dynamic pressure Pa
dF
p Fan dynamic pressure at outlet Pa
d2
p Fan static pressure Pa
sF
p Absolute stagnation pressure Pa

sg
p Average total pressure Pa

t
p Mean absolute pressure in space and time at a point Pa

x
−1
q Inlet mass flow rate kg⋅s
m
3 −1
q Inlet volume flow rate m s
V
Re Peripheral Reynolds number —
u
−1 −1
R Gas constant of fluid handled J⋅kg ⋅K
w
T Air flow test tolerance %
t Limit deviation specified —
−1
u Tip speed m⋅s
-1
v Fluid velocity m⋅s
c
p
Ratio of specific heats of air, κ = , where c is the massic heat
p
c
v

κ
capacity at constant pressure, and c is the massic heat capacity at
v
constant volume
η Fan efficiency —
η Fan optimum efficiency —
opt
θ Fluid absolute temperature at section x K
x
λ Power coefficient —
© ISO 2006 – All rights reserved 7

---------------------- Page: 12 ----------------------
ISO 13348:2006(E)
Symbol Term Unit
µ Dynamic viscosity Pa⋅s
−3
ρ Density kg⋅m
−3
ρ Mean density of gas in fan kg⋅m

m
−3
ρ Density at fan inlet kg⋅m
1
−3
ρ Density at fan outlet kg⋅m
2
ϕ Fan flow coefficient —
χ Dimensionless frequency —
ψ Pressure coefficient —
5 Performance tolerances for purpose-designed fans
5.1 Information to be provided by the purchaser
5.1.1 Operational
The following information shall be provided.
a) Volume flow rate, q , rate at the fan inlet or mass flow rate q .
V m
b) Total pressure increase, p , between fan inlet and outlet, or static pressure increase, p , at a specified
t s
discharge area.
c) Distribution of total pressure losses in the system between inlet and outlet side of fan.
d) Absolute pressure at fan inlet.
e) Density, ρ , of handled fluid at fan inlet.
1
f) Temperature of the gas handled at the fan inlet for normal operation relevant for the fan performance, and
the maximum and minimum temperatures for which the fan is to be designed.
g) Dust, mist or vapour content of gas at fan inlet for normal operation, the properties of these, and their
maximum content. Information as to whether the dust, mist or vapour is combustible, noxious, aggressive
or sticky.
h) Maximum permissible A-weighted sound power level, in A-weighted decibels, as specified in ISO 13347-1.
i) Maximum permissible levels of mechanical vibration in service, as specified in ISO 14694.
j) System characteristic, if necessary.
k) Design speed cycles: i.e. the number of speed cycles per 24 h, the range of speed, if variable speed, plus
the total number of start-stops the fan is to be designed for.
l) Other specifications (e.g. preferred rotational speed, type and range of control, orientation of the inlet and
discharge, impeller rotation, as viewed from the driver). See ISO 13349.
5.1.2 Tolerance grade
The tolerance grade shall be stated in accordance with the requirements specified in 5.3.1.
A supplier will only be able to provide a fan for a particular application once the customer has provided him
with all the information necessary to complete the order. This should take place before the tender is prepared
8 © ISO 2006 – All rights reserved

---------------------- Page: 13 ----------------------
ISO 13348:2006(E)
or, at the latest, before a sales agreement has been reached. Such information is to include details on fan
design, arrangement, construction, materials and scope of supply, and should be based on the customer’s
own calculations, measurements and experience in this field.
5.2 Information to be provided by the supplier
5.2.1 Essential information
If the supplier cannot refer to catalogue information, installation, maintenance or operation instructions, he
shall generally provide the following information.
a) Operational parameters at design conditions, especially volume or mass flow, fan pressure, absorbed
power and fan speed. The exact scope of supply, as well as any other accessories that the supplier
considers necessary for installation and connection (e.g. motors, devices to prevent accidental contact,
flexible connectors, control and shut-off devices, inlet boxes).
b) The major dimensions for connection, installation and transport.
c) The total mass of the assembly and the mass of the essential components supplied.
d) Important design features where essential for assembly, e.g. materials of construction. Other information
should be supplied on request, or if necessary.
e) Motor output power.
f) Other information, e.g. the electric or pneumatic connected load, provision of sealing gas, cooling air and
water.
g) Installation, operation, and maintenance instructions.
NOTE In many installations the electric drive motor is supplied directly by the supplier. As such, it may not be
possible to state the type of drive, its rating and speed, etc.
5.2.2 Optional parameters
The following information may also be provided.
a) Fan power (see ISO 5801) as a function of the parameters listed in 5.1.
b) Rotational speed of the impeller as a function of the parameters listed in 5.1, and maximum permissible
rotational speed.
c) A-weighted sound power level as specified in ISO 13347-1. Sound pressure levels are not recommended
as they can be heavily influenced by the room acoustics and sound propagation from connecting ducts. In
addition, they can be significantly influenced by directional characteristics, especially if the fan is of the
open-inlet or outlet type. Sound pressure levels can only be stated under free-field conditions and may
not be representative of actual room conditions.
d) Fan performance characteristic, if specifically requested by the purchaser. The following additional
parameters may be supplied if specifically requested:
1) fan efficiency (see ISO 5801) as a function of the parameters listed in 5.1;
2) vibration values (see ISO 14695);
3) balance quality (see ISO 14695).
e) The mass moment of inertia of the rotating parts, or if applicable, the starting torque curve.
© ISO 2006 – All rights reserved 9

---------------------- Page: 14 ----------------------
ISO 13348:2006(E)
5.3 Tolerances
5.3.1 Tolerance grades
Measuring uncertainties shall be considered differently from manufacturing tolerances.
At each stage of the fan design and manufacturing cycle, including conversion from prototype performance
data or calculation, fabrication and testing of a purpose-designed fan, finite uncertainties will prevail and
acceptance tolerances shall be applied.
Zero or exclusively positive tolerances can neither be supported in theory or practice and are not
recommended.
Uncertainties are spurious, random or systematic factors which affect design, fabrication and therefore fan
performance. Uncertainties are not absolute and because of this are handled statistically, i.e. a level of
confidence is attributed to the measured quantity lying within the uncertainty boundary of the true value.
Tolerances are the definition of acceptability for uncertainties. They are absolute and can vary according to
the application. They effectively define an absolute limit for uncertainties which would otherwise have to be
expressed statistically. The user is therefore provided with an absolute criteria for fan selection and
acceptance.
This International Standard acknowledges that there are two different sources of uncertainty influencing
performance tests.
Design and manufacturing processes have inherent dimensional uncertainties leading to deviations of
important mechanical dimensions from the target value. This, again, will lead to inevitable deviations in
performance data:
± t limit deviation of volume flow;
q
V
± t limit deviation of fan pressure;
p
F
± t limit deviation of fan shaft power;
P
a
− t limit deviation of fan efficiency;
η
+ t limit deviation of A-weighted fan sound power level.
L
WA
The design and manufacturing accuracy obtainable in practice is defined in a number of International
Standards. Design tolerances are treated in Clause 6 of this International Standard. Higher accuracy will, as a
rule, require more expensive production methods. The fan user shall decide which uncertainties in
performance data are permissible, bearing in mind the consequences on cost.
This can be illustrated for an axial fan with a cast impeller. The impeller could be a rough sand casting or a
more accurate die casting. The surface could be improved by polishing or remain untreated. The tip diameter
may be machined or remain as-cast. The aerodynamic effects of electric motors placed in the air stream may
reduce the fan performance. For low uncertainty it is not sufficient to achieve small tolerances for the tip gap,
etc. Larger or smaller deviations from the intended mechanical dimensions, and uncertainties in the
conversion of test data, will affect each performance value differently. For example, a variation of the width of
a radial impeller will have a larger influence on the volume flow-rate than on the fan pressure. Measurements
also have inherent uncertainties.
Limitations in the measuring accuracy of the instruments used, and deviations from the standardized test-duct
arrangements according to ISO 5801, will influence the confidence that can be applied to the uncertainty of
the resulting characteristic values, such as capacity, fan pressure, power consumption, speed and sound
power level. These values, being measured independently by different instruments, will have errors that are
10 © ISO 2006 – All rights reserved

---------------------- Page: 15 ----------------------
ISO 13348:2006(E)
unrelated and, as such, their influence on test results shall be considered independently. The following
tolerances are identified, taking into account potential imperfections of the measuring arrangement:
± ∆ tolerance of volume flow measurements;
q
V
± ∆ tolerance of fan pressure measurements;
p
F
± ∆ tolerance of fan shaft power measurements;
P
a
± ∆ tolerance of fan noise power measurements.
L
W
These tolerances are not limited to the errors of the instruments or the test arrangement employed. They also
allow for human error associated with the reading of the instruments and the interpolation of intermediate
values. This is particularly relevant for large fans, where the difficulty in achieving standardized test
arrangements may be the largest source of error.
To provide for the variety of fan types and applications, a list of four tolerance grades, with typical applications,
has been defined in Table 1. As indicated above, these range from accurately machined impellers for special-
purpose fans
...

NORME ISO
INTERNATIONALE 13348
Première édition
2006-03-01



Ventilateurs industriels — Tolérances,
méthodes de conversion et présentation
des données techniques
Industrial fans — Tolerances, methods of conversion and technical data
presentation




Numéro de référence
ISO 13348:2006(F)
©
ISO 2006

---------------------- Page: 1 ----------------------
ISO 13348:2006(F)
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.


©  ISO 2006
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse

ii © ISO 2006 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 13348:2006(F)
Sommaire Page
Avant-propos. iv
Introduction . v
1 Domaine d'application. 1
2 Références normatives . 1
3 Termes et définitions. 2
4 Symboles et unités . 6
5 Tolérances sur les performances pour les ventilateurs spéciaux . 8
5.1 Informations à fournir par l'acheteur. 8
5.2 Informations à fournir par le fournisseur. 9
5.3 Tolérances . 10
5.4 Arrangements commerciaux . 12
5.5 Essais contractuels . 12
6 Tolérances sur les performances pour les ventilateurs de série . 23
6.1 Tolérances dans les protocoles d'évaluation certifiés . 23
7 Méthodes de conversion. 28
7.1 Conversion des performances aérauliques expérimentales . 28
7.2 Conversion des résultats d'essais de puissance acoustique. 35
8 Présentation des données techniques.43
8.1 Généralités . 43
8.2 Informations essentielles. 43
8.3 Diagramme de performance du ventilateur . 44
8.4 Informations complémentaires . 46
Annexe A (normative) Documentation. 49
Annexe B (normative) Marquage . 50
Annexe C (informative) Résistance du système en fonction du débit. 51
Bibliographie . 54

© ISO 2006 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 13348:2006(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 13348 a été élaborée par le comité technique ISO/TC 117, Ventilateurs industriels.

iv © ISO 2006 – Tous droits réservés

---------------------- Page: 4 ----------------------
ISO 13348:2006(F)
Introduction
La présente Norme internationale vise à clarifier la précision des éléments techniques des contrats, pour ce
qui concerne la performance des ventilateurs, ainsi que l'exactitude et la cohérence des performances
publiées dans les catalogues techniques.
Dans la présente Norme internationale est établie une distinction entre les ventilateurs spéciaux, conçus pour
un but particulier ou pour satisfaire une spécification contractuelle, et les ventilateurs de série, dont les
performances figurent dans un catalogue.
Pour les ventilateurs spéciaux, les méthodes de calcul des performances dans des conditions contractuelles,
à partir de performances obtenues dans des conditions d’essai, sont décrites à l’Article 5, pour les
caractéristiques aérauliques et acoustiques. Quatre niveaux de tolérance sont donnés, applicables à un type
particulier de ventilateur et/ou d’application. Ces procédures se sont révélées satisfaisantes, toutefois le
fournisseur et l’utilisateur peuvent convenir d’adopter d’autres méthodes.
Pour les ventilateurs de série, les données techniques associées sont normalement présentes dans un
catalogue (sous forme électronique et/ou imprimée). Dans ce cas, la méthode d’application des tolérances est
telle que décrite à l’Article 6, basée sur les règles de l’AMCA International (Air Movement and Control
[11], [12], et [13]
Association International, Inc.) pour le protocole d’évaluation certifiée . Un organisme accrédité
indépendant peut être amené à vérifier ces données, en suivant un protocole d'évaluation certifié.

© ISO 2006 – Tous droits réservés v

---------------------- Page: 5 ----------------------
NORME INTERNATIONALE ISO 13348:2006(F)

Ventilateurs industriels — Tolérances, méthodes de conversion
et présentation des données techniques
1 Domaine d'application
La présente Norme internationale spécifie les tolérances sur les performances et la présentation des données
techniques des ventilateurs industriels de tous types. Elle ne s’applique pas aux ventilateurs conçus
uniquement pour le brassage de l’air, tels que ceux utilisés pour les besoins domestiques et analogues (par
exemple, ventilateurs plafonniers ou de table, ventilateurs d’extraction, etc.). Pour les ventilateurs
accélérateurs, voir l’ISO 13350.
−1
La limite supérieure du travail massique fourni par un ventilateur est normalement 25 kJ·kg , ce qui
correspond à une élévation de pression au ventilateur d’environ 30 kPa pour une masse volumique moyenne
−3
de 1,2 kg·m dans le ventilateur. Pour des valeurs supérieures, un accord doit être conclu entre le
fournisseur et l’utilisateur.
La présente Norme internationale couvre les quatre catégories d’installation définies dans l’ISO 5801:
A: aspiration libre, refoulement libre;
B: aspiration libre, refoulement en conduit;
C: aspiration en conduit, refoulement libre;
D: aspiration en conduit, refoulement en conduit.
La performance d’un ventilateur peut considérablement varier suivant la catégorie d’installation dans laquelle
il fonctionne. Ces catégories constituent donc une part importante de la définition de la description technique
des ventilateurs.
NOTE La reconnaissance internationale des quatre catégories d’installation fournit l’opportunité de baser un contrat
sur la catégorie de ventilateur la plus appropriée pour l’utilisateur final et pour le concepteur du système. Corrélativement,
la probabilité d’obtention d’un ventilateur apportant la performance convenue, sans compromis ni concession, s’en trouve
renforcée.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence s'applique (y compris les éventuels amendements).
ISO 5801:1997, Ventilateurs industriels — Essais aérauliques sur circuits normalisés
ISO 5802, Ventilateurs industriels — Essai de performance in situ
ISO 13347-1, Ventilateurs industriels — Détermination des niveaux de puissance acoustique des ventilateurs
dans des conditions de laboratoire normalisées — Partie 1: Présentation générale
ISO 14694, Ventilateurs industriels — Spécifications pour l'équilibrage et les niveaux de vibration
ISO 14695, Ventilateurs industriels — Méthode de mesure des vibrations des ventilateurs
© ISO 2006 – Tous droits réservés 1

---------------------- Page: 6 ----------------------
ISO 13348:2006(F)
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s'appliquent.
NOTE Dans certains cas, des définitions plus complètes peuvent être trouvées dans l’ISO 5801, l’ISO 5802 et
l’ISO 13349.
3.1
ventilateur industriel
ventilateur autre que ceux utilisés pour des applications domestiques ou similaires, telles que brassage d’air,
climatisation
NOTE Pour les besoins de la présente Norme internationale et d’autres normes concernant les ventilateurs
industriels, un ventilateur à usage domestique est défini comme ayant un moteur monophasé fonctionnant à 250 V et 16 A
au maximum. Avec un démarrage suffisamment progressif, cela correspond à une puissance absorbée ne dépassant pas
3 kW.
3.2
ventilateur de série
ventilateur sur catalogue
ventilateur dont les performances détaillées sont largement disponibles dans un catalogue (électronique et/ou
imprimé), et qui est fabriqué fréquemment en quantités significatives et disponible à court délai
3.3
pression moyenne de stagnation dans une section x
p
sgx
somme de la pression dynamique conventionnelle, p , corrigée par le coefficient du facteur de Mach, F ,
dx Mx
dans la section considérée, et de la pression absolue moyenne, p
x
p =+pp F
sgx x dx Mx
NOTE 1 La pression moyenne de stagnation peut être calculée à partir de l’expression
κ
⎛⎞κ−1 κ−1
2
pp=+1 Ma
sgx x⎜⎟x
2
⎝⎠
NOTE 2 La pression moyenne de stagnation est exprimée en pascals (Pa).
3.4
pression totale dans une section x
p

tx
somme de la pression dynamique conventionnelle, p , corrigée par le coefficient du facteur de Mach, F ,
dx Mx
dans la section considérée, et de la pression effective moyenne, p
ex
p=+ppF=p−p
tx ex dx Mx sgx a
NOTE 1 Lorsque le nombre de Mach, Ma, est inférieur à 0,122, le facteur de Mach, F , peut être négligé.
Mx
NOTE 2 Voir l'ISO 5801, l'ISO 5802 et l'ISO 13349 pour des définitions.
3.5
erreur caractéristique
variation de débit résultant, selon la caractéristique effective du système, de l’écart maximal de performance
du ventilateur permis par le niveau de tolérance choisi
NOTE 1 L’erreur caractéristique dépend du niveau de tolérance, de l’incertitude de mesure permise et de la forme
(pente locale) des caractéristiques du ventilateur et du système.
NOTE 2 Pour les caractéristiques effectives des systèmes, voir l’ISO 5801.
2 © ISO 2006 – Tous droits réservés

---------------------- Page: 7 ----------------------
ISO 13348:2006(F)
3.6
courbes des caractéristiques aérodynamiques d’un ventilateur
pression, puissance, rendement, etc. du ventilateur en fonction du débit, dans des conditions ambiantes
spécifiées et à vitesse constante, ou avec un moteur spécifié
3.7
pression dynamique au refoulement du ventilateur
p
d2
pression dynamique conventionnelle au refoulement, calculée à partir du débit-masse, de la masse volumique
moyenne au refoulement et de l’aire de l’ouïe de refoulement
2
2
vq1⎛⎞
m2 m
p==ρ
⎜⎟
d2 2
22ρ A
22⎝⎠
NOTE La pression dynamique au refoulement du ventilateur est exprimée en pascals (Pa).
3.8
coefficient de débit du ventilateur
ϕ
coefficient sans dimension égal au débit-masse divisé par le produit de la masse volumique moyenne par la
vitesse périphérique de la roue et par le carré du diamètre de la roue
q
m
ϕ= si MaW 0,122
2
ρ uD
mr
q
V
ϕ= 2
uD
r
3.9
aire de l’ouïe de refoulement
A
2
aire intérieure de la bride de l’enveloppe du ventilateur au refoulement
2
NOTE L'aire de l’ouïe de refoulement est exprimée en mètres carrés (m ).
3.10
pression du ventilateur
p
F
différence entre les pressions de stagnation au refoulement et à l’aspiration du ventilateur
p=−pp si Ma W 0,15
Fsg2 sg1
p==pp−p si Ma < 0,15
FtFt2 t1
NOTE 1 Il convient que la pression du ventilateur se réfère aux catégories d’installation, A, B, C ou D.
NOTE 2 La pression du ventilateur est exprimée en pascals (Pa).
3.11
pression statique du ventilateur
p
sF
grandeur conventionnelle définie comme la différence entre la pression du ventilateur et la pression
dynamique corrigée par le facteur de Mach, F
M2
© ISO 2006 – Tous droits réservés 3

---------------------- Page: 8 ----------------------
ISO 13348:2006(F)
p=−ppF−p=p−p si Ma W 0,122 au refoulement du ventilateur
sF sg2d2M2sg1 2sg1
p=−pp−p si Ma < 0,122 au refoulement du ventilateur
sF t2 t1 d2
NOTE La pression statique du ventilateur est exprimée en pascals (Pa).
3.12
facteur de Mach
F
M
facteur de correction appliqué à la pression dynamique en un point
p − p
sg
F =
M
p
d
NOTE 1 Le facteur de Mach peut être calculé par
24 6
Ma (2−−κκ)Ma (2 )(3− 2κ)Ma
F =+1.+ + +. valide pour κ = 1,4.
M
4 24 192
NOTE 2 Le facteur de Mach est sans dimension.
3.13
nombre de Mach en un point
Ma
rapport de la vitesse du gaz en un point et de la vitesse du son
vv
Ma==
c
κΘR
w

c est la vitesse du son, cR=κΘ ;
w
R est la constante massique du gaz humide.
w
NOTE Le nombre de Mach est sans dimension.
3.14
nombre de Mach dans une section x
Ma
x
vitesse moyenne du gaz divisée par la vitesse du son dans la section transversale spécifiée du circuit d’air
v
mx
Ma =
x
κΘR
wx
NOTE Le nombre de Mach est sans dimension.
3.15
rendement optimal
η
opt
rendement maximal obtenu d’après la caractéristique aéraulique du ventilateur, tous les paramètres de
fonctionnement étant fixés à l’exception de la résistance aéraulique du système
NOTE Le rendement est exprimé en pourcentage.
4 © ISO 2006 – Tous droits réservés

---------------------- Page: 9 ----------------------
ISO 13348:2006(F)
3.16
nombre de Reynolds périphérique
Re

u
nombre de Reynolds basé sur la vitesse périphérique des pales de la roue, u
NOTE Le nombre de Reynolds périphérique est sans dimension.
3.17
coefficient de puissance
λ
grandeur sans dimension relative à la puissance à l'arbre et basée sur la masse volumique moyenne du fluide
à l’aspiration
P
r
λ=
32
ρ uD
mr
3.18
coefficient de pression
ψ
grandeur sans dimension relative à la pression du ventilateur et basée sur la masse volumique moyenne et la
vitesse à l’extrémité de la roue
p
F
ψ=
2
ρ u
m
3.19
vitesse périphérique
u
vitesse périphérique des pales de la roue au niveau de leur diamètre maximal
−1
NOTE La vitesse périphérique est exprimée en mètres par seconde (m⋅s ).
3.20
niveau de puissance acoustique total
L
W
niveau total de puissance acoustique, non pondéré, défini comme 10 fois le logarithme décimal du quotient de
−12
la puissance acoustique en watts sur une valeur de référence de 10 watts (1 picowatt [pW])
NOTE Le niveau de puissance acoustique total est exprimé en décibels (dB).
3.21
niveau de puissance acoustique dans une bande d’octave
L
Wfc
niveau de puissance acoustique dans une bande d’octave centrée sur une fréquence définie, défini comme
10 fois le logarithme décimal du quotient de la puissance acoustique en watts sur une valeur de référence de
−12
10 watts (1 picowatt [pW])
NOTE Le niveau de puissance acoustique dans une bande d’octave est exprimé en décibels (dB).
3.22
niveau de puissance acoustique pondéré A
L
WA
niveau de puissance acoustique total utilisant une pondération A
NOTE 1 Voir la norme CEI 61672-1 pour une définition de la pondération A.
NOTE 2 Le niveau de puissance acoustique pondéré A est exprimé en décibels (dB).
© ISO 2006 – Tous droits réservés 5

---------------------- Page: 10 ----------------------
ISO 13348:2006(F)
3.23
niveau de pression acoustique total
L
p
en un point spécifié, et dans les conditions spécifiées, niveau total de pression acoustique, non pondéré,
normalement dans les bandes d'octave centrées sur les fréquences allant de 63 Hz à 8 kHz, défini comme
10 fois le logarithme décimal du quotient du carré de la pression acoustique sur le carré d’une valeur de
référence de 20 micropascals (20 µPa)
NOTE Le niveau de puissance acoustique total est exprimé en décibels (dB).
3.24
niveau de pression acoustique pondéré A
L
pA
niveau de pression acoustique utilisant une pondération A
NOTE 1 Voir la norme CEI 61672-1 pour une définition de la pondération A.
NOTE 2 Le niveau de puissance acoustique pondéré A est exprimé en décibels (dB).
3.25
zone de tolérance
plage des valeurs des paramètres spécifiés permises, conformément au niveau de tolérance applicable
3.26
niveau de tolérance
désignation définissant les écarts limites par rapport aux performances techniques convenues ou publiées
3.27
fréquence sans dimension
χ
fonction logarithmique sans dimension du rapport entre la fréquence centrale d’une bande d'octave ou de tiers
d’octave et la vitesse de rotation du ventilateur
f
c
χ= 10 lg
n
4 Symboles et unités
Pour les besoins du présent document, les symboles suivants s’appliquent:
Symbole Terme Unité
2
A
Aire de l'ouïe de refoulement du ventilateur
m
2
−1
c
Vitesse du son
m·s
D Diamètre de la roue à aubes m
r
e
Incertitude de mesure —
F Facteur de Mach pour la correction de la pression dynamique dans une section x —

Mx
f Fréquence centrale d'une octave Hz

c
G Indice d'une valeur convenue —
2
k —
Constante parabolique k = ψ /ϕ
p
L Niveau de pression acoustique total, non pondéré dB

p
6 © ISO 2006 – Tous droits réservés

---------------------- Page: 11 ----------------------
ISO 13348:2006(F)
Symbole Terme Unité
L Niveau de pression acoustique pondéré A dB (A)
pA
L Niveau de puissance acoustique total, non pondéré dB
W
L Niveau de puissance acoustique pondéré A dB (A)
WA
L Niveau de puissance acoustique d'une bande d'octave dB
Wf
c
M Indice d'une valeur mesurée —
Ma Nombre de Mach en un point —
Ma Nombre de Mach dans une section x —
x
−1
n
Vitesse de rotation
r·s
P Puissance mécanique fournie à l’arbre du ventilateur W
a
P Puissance mécanique requise par la roue du ventilateur W
r
P Puissance à l'arbre du moteur électrique W
m
p Pression atmosphérique Pa
a
p Pression effective moyenne dans le temps et l’espace, dans une section x Pa
ex
p Pression du ventilateur Pa
F
p Pression dynamique du ventilateur Pa
dF
p Pression dynamique du ventilateur au refoulement Pa
d2
p Pression statique du ventilateur Pa

sF
p Pression de stagnation absolue Pa

sg
p Pression totale moyenne Pa

t
p Pression absolue moyenne spatio-temporelle en un point Pa
x
−1
q Débit-masse à l'aspiration
kg·s
m
3 −1
q Débit-volume à l'aspiration
m s
V
Re Nombre de Reynolds périphérique —
u
−1 −1
R Constante des gaz du fluide véhiculé
J·kg ·K
w
T Tolérance sur le débit pour l'essai de contrôle %
t Écart limite spécifié —
−1
u Vitesse à l'extrémité de la roue
m·s
−1
v
Vitesse du fluide
m·s
c
p
Exposant isentropique de l'air, κ = , où c est la capacité thermique massique —
κ
p
c
v
à pression constante et c est la capacité thermique massique à volume constant
v
Rendement du ventilateur —
η
Rendement optimal du ventilateur —
η
opt
θ Température absolue du fluide dans une section x K
x
© ISO 2006 – Tous droits réservés 7

---------------------- Page: 12 ----------------------
ISO 13348:2006(F)
Symbole Terme Unité
Coefficient de puissance —
λ
Viscosité dynamique
µ Pa⋅s
−3
Masse volumique
ρ
kg·m
−3
Masse volumique moyenne du gaz dans le ventilateur
ρ
kg·m

m
−3
Masse volumique à l’aspiration
ρ
kg·m
1
−3
ρ Masse volumique au refoulement
kg·m
2
ϕ Coefficient de débit du ventilateur —
Fréquence sans dimension —
χ
Coefficient de pression —
ψ
5 Tolérances sur les performances pour les ventilateurs spéciaux
5.1 Informations à fournir par l'acheteur
5.1.1 Fonctionnement
Les informations suivantes doivent être fournies.
a) Le débit-volume à l'aspiration, q , ou le débit-masse, q .
V m
b) L'élévation de pression totale, p, entre l'aspiration et le refoulement du ventilateur, ou l'élévation de
t
pression statique, p , sur une surface de décharge spécifiée.
s
c) La répartition des pertes de pression totales dans le système entre les côtés aspiration et refoulement du
ventilateur.
d) La pression absolue à l'aspiration du ventilateur.
e) La masse volumique, ρ , du fluide véhiculé à l'aspiration du ventilateur.
1
f) La température du gaz véhiculé à l'aspiration du ventilateur en fonctionnement normal, à prendre en
compte pour la performance du ventilateur, et les températures minimale et maximale pour lesquelles le
ventilateur doit être conçu.
g) La teneur en poussières, gouttelettes ou vapeur du gaz à l'aspiration du ventilateur en fonctionnement
normal, leurs propriétés et leurs teneurs maximales. Informations sur le caractère combustible, nocif,
agressif ou collant de ces poussières, gouttelettes ou vapeurs.
h) Le niveau maximal admissible de niveau de puissance acoustique pondéré A, en dB (A), comme spécifié
dans l'ISO 13347-1.
i) Les niveaux maximaux admissibles des vibrations mécaniques en service, comme spécifié dans
l'ISO 14694.
j) La caractéristique du système, si nécessaire.
k) Les cycles de vitesse de conception. C'est-à-dire, le nombre de cycles de vitesse sur 24 heures, la plage
des vitesses, si vitesse variable, ainsi que le nombre de séquences marche-arrêt pour lequel le
ventilateur est conçu.
8 © ISO 2006 – Tous droits réservés

---------------------- Page: 13 ----------------------
ISO 13348:2006(F)
l) Toute autre spécification (par exemple: la vitesse de rotation préférée, le type et la plage de régulation,
l'orientation de l'aspiration et du refoulement, sens de rotation de la roue vue depuis l'entraînement). Voir
l'ISO 13349.
5.1.2 Niveau de tolérance
Le niveau de tolérance doit être formulé conformément aux exigences spécifiées en 5.3.1.
Il est à noter qu’un fournisseur ne sera en mesure de fournir un ventilateur pour une application particulière
que lorsque le client lui aura fourni tous les renseignements nécessaires à la mise au point de la commande.
Il est recommandé que cela intervienne avant l'élaboration de l'offre ou, au plus tard, avant la conclusion d'un
accord commercial. Cette information doit comprendre des éléments sur la conception, la disposition, la
construction, les matériaux constitutifs et le domaine d'utilisation du ventilateur, et il convient qu'elle soit basée
sur les propres calculs, mesures et expérience du client dans ce domaine.
5.2 Informations à fournir par le fournisseur
5.2.1 Informations essentielles
Si le fournisseur ne peut se référer aux informations d'un catalogue ou à des instructions d'installation, de
maintenance ou de fonctionnement, il doit en règle générale fournir les informations suivantes.
a) Les paramètres de fonctionnement aux conditions de conception, notamment le débit-masse ou le débit-
volume, la pression du ventilateur, la puissance absorbée et la vitesse du ventilateur. Le domaine précis
d’utilisation, ainsi que tout autre accessoire considéré par le fournisseur comme nécessaire à son
installation et à son raccordement (par exemple: moteurs, dispositifs de prévention des contacts
accidentels, raccordements flexibles, dispositifs de régulation et de coupure, caissons d'aspiration).
b) Les principales dimensions pour le raccordement, l'installation et le transport.
c) La masse totale de l'ensemble et la masse des composants essentiels fournis.
d) Les aspects importants de la conception essentiels pour le montage, par exemple matériaux constitutifs.
Il convient de fournir d'autres renseignements sur demande, ou si nécessaire.
e) La puissance utile du moteur.
f) Toute autre information d'ordre général, par exemple le calibrage des branchements électriques ou
pneumatiques, les besoins en gaz d'étanchéité ou en air et eau de refroidissement.
g) Les instructions d'installation, de conduite et de maintenance.
NOTE Dans toutes les installations, le moteur électrique d’entraînement est fourni directement par le fournisseur. Si
bien qu’il n’est pas possible d’indiquer le type d’entraînement, ses performances et sa vitesse.
5.2.2 Paramètres optionnels
Les informations suivantes peuvent être fournies en option.
a) La puissance du ventilateur (voir l'ISO 5801) en fonction des paramètres énumérés en 5.1.
b) La vitesse de rotation de la roue en fonction des paramètres énumérés en 5.1, et la vitesse de rotation
maximale admissible.
c) Le niveau de puissance acoustique pondéré A comme spécifié dans l'ISO 13347-1. Les niveaux de
pression acoustique ne sont pas recommandés car ils peuvent être largement influencés par l'acoustique
du local et par la propagation du son dans les conduits de raccordement. De plus, ils peuvent être
significativement influencés par les caractéristiques directionnelles, en particulier si le ventilateur est du
© ISO 2006 – Tous droits réservés 9

---------------------- Page: 14 ----------------------
ISO 13348:2006(F)
type refoulant ou aspirant. Les niveaux de pression acoustique ne peuvent être indiqués qu'en condition
de champ libre et ne peuvent pas être représentatifs des conditions réelles dans un local.
d) La caractéristique de performance du ventilateur, si l'acheteur en fait spécifiquement la demande. Sur
demande spécifique, les paramètres supplémentaires suivants peuvent être fournis:
1) rendement du ventilateur (voir l'ISO 5801) en fonction des paramètres énumérés en 5.1;
2) valeurs des vibrations (voir l’ISO 14695);
3) qualité de l'équilibrage (voir l’ISO 14695).
e) Le moment d'inertie des parties rotatives, ou, le cas échéant, la courbe du couple de démarrage.
5.3 Tolérances
5.3.1 Niveaux de tolérance
Les incertitudes de mesurage doivent être considérées directement à partir des tolérances de fabrication.
À chaque étape de la conception du ventilateur et du cycle de fabrication, y compris lors de la conversion des
données de performance d'un prototype, ou lors du calcul, de la fabrication et de l'essai d'un ventilateur
spécial, des inc
...

Questions, Comments and Discussion