Acoustics -- Measurement of room acoustic parameters

Acoustique -- Mesurage des paramètres acoustiques des salles

General Information

Status
Published
Current Stage
4020 - DIS ballot initiated: 5 months
Start Date
29-Jan-2021
Completion Date
29-Jan-2021
Ref Project

RELATIONS

Buy Standard

Draft
ISO/DIS 3382-3 - Acoustics -- Measurement of room acoustic parameters
English language
18 pages
sale 15% off
Preview
sale 15% off
Preview
Draft
ISO/DIS 3382-3 - Acoustique -- Mesurage des paramètres acoustiques des salles
French language
21 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (sample)

DRAFT INTERNATIONAL STANDARD
ISO/DIS 3382-3
ISO/TC 43/SC 2 Secretariat: DIN
Voting begins on: Voting terminates on:
2021-01-29 2021-04-23
Acoustics — Measurement of room acoustic parameters —
Part 3:
Open plan offices
Acoustique — Mesurage des paramètres acoustiques des salles —
Partie 3: Bureaux ouverts
ICS: 91.120.20
THIS DOCUMENT IS A DRAFT CIRCULATED
This document is circulated as received from the committee secretariat.
FOR COMMENT AND APPROVAL. IT IS
THEREFORE SUBJECT TO CHANGE AND MAY
NOT BE REFERRED TO AS AN INTERNATIONAL
STANDARD UNTIL PUBLISHED AS SUCH.
IN ADDITION TO THEIR EVALUATION AS
ISO/CEN PARALLEL PROCESSING
BEING ACCEPTABLE FOR INDUSTRIAL,
TECHNOLOGICAL, COMMERCIAL AND
USER PURPOSES, DRAFT INTERNATIONAL
STANDARDS MAY ON OCCASION HAVE TO
BE CONSIDERED IN THE LIGHT OF THEIR
POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN
Reference number
NATIONAL REGULATIONS.
ISO/DIS 3382-3:2021(E)
RECIPIENTS OF THIS DRAFT ARE INVITED
TO SUBMIT, WITH THEIR COMMENTS,
NOTIFICATION OF ANY RELEVANT PATENT
RIGHTS OF WHICH THEY ARE AWARE AND TO
PROVIDE SUPPORTING DOCUMENTATION. ISO 2021
---------------------- Page: 1 ----------------------
ISO/DIS 3382-3:2021(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2021

All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may

be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting

on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address

below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2021 – All rights reserved
---------------------- Page: 2 ----------------------
ISO/DIS 3382-3:2021(E)
Contents Page

Foreword ........................................................................................................................................................................................................................................iv

Introduction ..................................................................................................................................................................................................................................v

1 Scope ................................................................................................................................................................................................................................. 1

2 Normative references ...................................................................................................................................................................................... 1

3 Terms and definitions ..................................................................................................................................................................................... 1

4 Measurement conditions ............................................................................................................................................................................. 3

4.1 Equipment ................................................................................................................................................................................................... 3

4.2 Measurement procedure ................................................................................................................................................................ 3

4.2.1 Measurement conditions .......................................................................................................................................... 3

4.2.2 Room acoustic zones .................................................................................................................................................... 3

4.2.3 Source and microphone positions .................................................................................................................... 4

4.2.4 Measurement quantities ........................................................................................................................................... 5

5 Determination of single-number quantities ........................................................................................................................... 6

5.1 Spectrum of normal speech ......................................................................................................................................................... 6

5.2 Spatial decay rate of speech ......................................................................................................................................................... 6

5.2.1 Conventional method ................................................................................................................................................... 6

5.2.2 Impulse response method ....................................................................................................................................... 8

5.3 Speech level at 4 m distance ........................................................................................................................................................ 8

5.4 Background noise ................................................................................................................................................................................. 9

5.5 Speech Transmission Index ......................................................................................................................................................... 9

5.6 Comfort and distraction distances ......................................................................................................................................10

5.7 Typical values of single-number quantities ................................................................................................................11

6 Precision ....................................................................................................................................................................................................................11

7 Test report ................................................................................................................................................................................................................11

Annex A (informative) Psychological reasoning of distraction distance .....................................................................13

Annex B (informative) Alternative methods for determining the spatial decay rate .....................................14

Annex C (informative) Examples of typical values of the single-number quantities .......................................16

Annex D (informative) Accuracy ............................................................................................................................................................................17

Bibliography .............................................................................................................................................................................................................................18

© ISO 2021 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO/DIS 3382-3:2021(E)
Foreword

ISO (the International Organization for Standardization) is a worldwide federation of national standards

bodies (ISO member bodies). The work of preparing International Standards is normally carried out

through ISO technical committees. Each member body interested in a subject for which a technical

committee has been established has the right to be represented on that committee. International

organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.

ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of

electrotechnical standardization.

The procedures used to develop this document and those intended for its further maintenance are

described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the

different types of ISO documents should be noted. This document was drafted in accordance with the

editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).

Attention is drawn to the possibility that some of the elements of this document may be the subject of

patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of

any patent rights identified during the development of the document will be in the Introduction and/or

on the ISO list of patent declarations received (see www .iso .org/ patents).

Any trade name used in this document is information given for the convenience of users and does not

constitute an endorsement.

For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and

expressions related to conformity assessment, as well as information about ISO's adherence to the

World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www .iso .org/

iso/ foreword .html.

This document was prepared by Technical Committee [or Project Committee] ISO/TC 43, Acoustics,

Subcommittee SC 2, Building acoustics.

This second edition cancels and replaces the first edition (ISO 3382-3:2012), which has been technically

revised. The main changes compared to the previous edition are as follows:

— new single-number quantity, comfort distance, added, and privacy distance removed;

— use of omnidirectional sound source emphasized;
— measurement conditions (Clause 4) have been clarified;
— determination of single-number quantities (Clause 5) clarified;
— use of impulse response method better described and a new Annex added;
— new Clause 6 Precision and a new informative Annex Accuracy added;

— STI is determined in conformance of IEC 20268-16 using weighting factors α and β for male gender;

A list of all parts in the ISO 3382 series can be found on the ISO website.

Any feedback or questions on this document should be directed to the user’s national standards body. A

complete listing of these bodies can be found at www .iso .org/ members .html.
iv © ISO 2021 – All rights reserved
---------------------- Page: 4 ----------------------
ISO/DIS 3382-3:2021(E)
Introduction

Noise and lack of speech privacy are among the most dissatisfactory environmental factors in open-

plan offices [1]. Colleagues’ speech is the main source of office noise. Inadequate room acoustic design

of the office is one reason to the perception of noise and lack of speech privacy. Distraction due to

colleagues’ speech weakens the ability to concentrate and reduces productivity, especially in tasks

requiring cognitive resources. Insufficient speech privacy prevents confidential conversations. Several

experimental studies suggest that distraction can be reduced by reducing speech intelligibility [2,3].

A large field survey supports that reduced speech intelligibility is associated with reduced noise

disturbance [4].

This part of ISO 3382 specifies a measurement method, which results in a group of single-number

quantities indicating the room acoustic performance of an open-plan office in a condition when one

person is speaking. They focus on spatial decay of speech while quantities in part 2 of this standard

focus on temporal decay of sound.

The concept "open-plan offices" covers large office spaces where large number of occupants can work in

well-defined workstations. A large share of flexible offices and activity-based offices belong to the open-

plan office concept of this standard. Open-plan offices can also be found in libraries, hospital wards,

industrial workplaces, and schools. According to [4], many of the single-number quantities provided by

this standard are associated with the perceived noise disturbance in open-plan offices.

Room acoustic quality can be affected by the amount and positioning of absorption materials, room

geometry, workstations, screens, other furniture, and background noise level, i.e. sound masking.

Current literature gives good advice how the room acoustics should be designed to reach good room

acoustic quality as it is defined in this standard [5,6,7].

The method describes the acoustic performance of the open-plan office in a standardized condition

where a single occupant is speaking with normal speech effort. The background noise caused by

building appliances or electronic masking sound is considered. The measurements are conducted in

an unoccupied open-plan office because the method concerns the permanent building properties and

stable room acoustic conditions as well as parts 1 and 2 of this standard. The actual noise conditions

during use of the space do not belong to the scope of this standard. Although the activity noise caused

by occupants can be significantly larger than the background noise from building appliances or sound

masking, activity noise is beyond the scope of this standard. Presentation of acoustic design guidelines

is also beyond the scope of this part of ISO 3382-3.
© ISO 2021 – All rights reserved v
---------------------- Page: 5 ----------------------
DRAFT INTERNATIONAL STANDARD ISO/DIS 3382-3:2021(E)
Acoustics — Measurement of room acoustic parameters —
Part 3:
Open plan offices
1 Scope

This document specifies methods for the measurement of room acoustic parameters in unoccupied

open-plan offices. It specifies measurement procedures, the apparatus needed, the coverage required,

the method for evaluating the data, and the presentation of the test report.
2 Normative references

The following documents are referred to in the text in such a way that some or all of their content

constitutes requirements of this document. For dated references, only the edition cited applies. For

undated references, the latest edition of the referenced document (including any amendments) applies.

ISO 3382-1, Acoustics — Measurement of room acoustic parameters — Part 1: Performance spaces

ISO 3740, Acoustics — Determination of sound power levels of noise sources — Guidelines for the use of

basic standards

IEC 60268-16:2011, Sound system equipment — Part 16: Objective rating of speech intelligibility by speech

transmission index
IEC 60942, Electroacoustics — Sound calibrators
IEC 61260, Electroacoustics — Octave-band and fractional-octave-band filters
IEC 61672-1, Electroacoustics — Sound level meters — Part 1: Specifications
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.

ISO and IEC maintain terminological databases for use in standardization at the following addresses:

— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at http:// www .electropedia .org/
3.1
Omnidirectional sound source
OSS
a sound source which radiates sound evenly to all directions.
3.2
spatial distribution of the A-weighted SPL of speech

curve which shows how the A-weighted sound pressure level (SPL) decreases as a function of the

distance from the middle point of the OSS emitting noise with the sound power level of normal speech

within 125 Hz to 8 000 Hz.
© ISO 2021 – All rights reserved 1
---------------------- Page: 6 ----------------------
ISO/DIS 3382-3:2021(E)
3.3
spatial decay rate of speech
2,S

rate of spatial decay of A-weighted SPL of speech per distance doubling in decibels

Note 1 to entry: The quantity describes how fast the A-weighted SPL of speech attenuates in the open-plan office.

Large value means strong overall room acoustic attenuation. In free field, D = 6 dB.

2,S
3.4
Speech level at 4 m distance
p,A,S,4m

nominal A-weighted SPL in decibels at the distance of 4,0 m from the middle point of the OSS emitting

noise with the sound power level of normal speech within 125 Hz to 8 000 Hz

Note 1 to entry: The quantity describes the A-weighted SPL of speech at a distance within which the nearest

workstation is nearly always located. Small value means strong room acoustic attenuation near the OSS.

3.5
comfort distance

distance from the speaker in meters where the A-weighted SPL of speech falls below 45 dB when the

OSS is emitting noise with the sound power level of normal speech within 125 Hz to 8 000 Hz

Note 1 to entry: Comfort distance reduces with increasing D2,S and decreasing Lp,A,S,4m.

3.6
background noise level
p,B

unweighted mean SPL of background noise in decibels present at the workstations along the

measurement path during working hours when occupants are absent

Note 1 to entry: Background noise is measured in octave bands within 125 Hz to 8 000 Hz.

3.7
speech transmission index
STI

a proportional number representing the transmission quality of speech. STI has a value between 0.00

and 1.00.
[SOURCE: IEC 60268-16:2011]

Note 1 to entry: The value of STI is associated with subjective speech intelligibility.

3.8
spatial distribution of the speech transmission index

curve which shows how the STI decreases as a function of the distance from the OSS.

3.9
distraction distance
distance from the OSS in meters where the STI falls below 0,50.

Note 1 to entry: to entry. Distraction distance reduces with decreasing r and increasing L . Small value

C p,B

indicates high speech privacy. When the speaker is located beyond the distraction distance from the occupant,

occupant’s work performance is expected to be better than at shorter distances (see Annex A).

3.10
Workstation

Workstation is a furniture ensemble containing one ergonomically adjustable chair and a working table

having a minimum floor area of 70x70 cm. The height of tabletop can be adjusted to a height of 75

cm from the floor. Workstation can contain also other components, such as screen(s), storage unit(s),

display units, or luminaire.
2 © ISO 2021 – All rights reserved
---------------------- Page: 7 ----------------------
ISO/DIS 3382-3:2021(E)
4 Measurement conditions
4.1 Equipment

4.1.1 Sound source. Omnidirectional sound source (abbreviated by OSS) shall be used in all

measurements. This source type is used since occupants in an open-plan office do not speak in an exactly

fixed direction. The requirements given in ISO 3382-1 for the OSS within 125 – 4000 Hz shall be fulfilled

for measurements to be in accordance with this part of ISO 3382.
NOTE There are no requirements for the 8 000 Hz octave band.

4.1.2 Microphone. SPLs in each octave band and at each microphone position shall be measured

using a sound level meter meeting the requirements of IEC 61672-1, class 1. The microphone shall be

omnidirectional considering any supplementary equipment connected to it.

4.1.3 Analyzer. The octave-band filters of the analyzer or analyzer software shall comply with

IEC 61260. If the signal is recorded, e.g., by using analogue or digital recorders for off-line processing, it

shall be ensured that the whole instrumentation complies with the above-mentioned requirements.

4.1.4 Calibrator. Before and after each measurement series, the acoustical sensitivity of the

measurement system shall be checked using a sound calibrator that complies with IEC 60942. The results

of the calibration checks shall be documented. A difference of more than 0,5 dB between calibration

checks shall be a cause to repeat measurements. It is recommended that the calibration be checked

whenever batteries or open-plan office are changed.
4.2 Measurement procedure
4.2.1 Measurement conditions

Measurements can be conducted in open-plan offices of any kind and with any configuration of ceiling

absorbers, wall absorbers, sound masking systems, floor coverings, fixed partitions, workstations,

screens, storage units, and other furniture, whether they are fixed or mobile. The results are valid only

to the specified configuration which prevails during the measurement. Therefore, it is important to

carefully report these factors along with the measurement results.

Background noise means all stationary sounds, which are present during normal working hours

and are not caused by the occupants. Such sounds are e.g. heating, ventilation, and air conditioning

(HVAC) devices, environmental noise caused by sources outside the building, or an electronic sound-

masking system.

The HVAC devices shall operate on the same power as during typical working hours. If the office is

equipped with a sound-masking system, it shall be switched on during the measurement. Sound

masking shall operate at the same level and with the same spectrum as during typical working hours.

Adaptive masking systems should be tested separately for minimum and maximum levels. Appliances

such as refrigerators, printers, coffee machines, radios, and video projectors shall be shut down if they

increase the background noise in any measurement position. Windows and balcony doors shall be

closed. All measurements shall be conducted when the occupants are absent. Only the measurement

technician can be present in the open-plan office.

If the table heights are electrically adjustable, the tabletop height is set to 75±5 cm from the floor in the

workstations located along the measurement path.
4.2.2 Room acoustic zones

If the open-plan offices can contain two or more zones where the absorption treatments and/or

furniture layouts are different, the measurements shall be conducted in each zone and the reported

single-number quantities are determined for each zone separately.
© ISO 2021 – All rights reserved 3
---------------------- Page: 8 ----------------------
ISO/DIS 3382-3:2021(E)

At least two separate measurement paths shall be used per open-plan office zone. If only one

measurement path is possible, measurements shall be conducted in both directions along the same

measurement path.
4.2.3 Source and microphone positions

The measurements shall be conducted along a straightest possible path which crosses over

workstations, as shown in Figure 1.

If the zone contains regular furniture (usually screen or storage unit) between workstations, the

measurement path should be chosen in such a way that there is an obstacle between the OSS and the

first measurement position.

The OSS is located at the workstation at one end of the path. The OSS shall be located at the position of

a sitting occupant’s head in a workstation. The middle point of the OSS shall be at the height of 1,2 m

above the floor. The position of the OSS shall be at least 0,4 m from the nearest table and at least 1,0 m

from walls and other reflecting surfaces.

All workstations shall be measured along the measurement path and considered in the analysis. The

number of measurement positions on a path shall be at least 4. In other words, measurements according

to this standard are only possible if measurement path involves at least five consecutive workstations.

The preferred number of successive measurement positions on the path is 6 to 10.

The reference position shall be located at the distance of 1,0 m from the middle point of the OSS without

any separating obstacles, such as a screen, between the OSS and the microphone. The reference position

needs not to locate in the direction of the measurement path if an obstacle prevents the abovementioned

condition. The reference position enables a post check of the actual sound power level of the OSS.

Although the position is not utilized in the determination of the single-number quantities, the result

can be shown in spatial decay curves of both A-weighted SPL of speech and STI to provide additional

information about the acoustic conditions at short conversation distance.

The actual measurement positions, which affect the reported single-number quantities, shall locate in

workstations along the measurement path at the position of a sitting occupant’s head at the height of

1,2 m above the floor. The second measurement position shall locate in the workstation nearest to the

OSS. Standing occupants are not considered in this part of ISO 3382. The position of microphone shall

be at least 0,4 m from tables and at least 1,0 m from walls and other reflecting surfaces.

Even if electric tables enable working in standing position, both OSS and microphones shall be installed

at a height of 1.20 m height from the floor.
4 © ISO 2021 – All rights reserved
---------------------- Page: 9 ----------------------
ISO/DIS 3382-3:2021(E)
Key
A straight measurement path
B non-straight measurement path

Figure 1 — Example of a straight and a non-straight measurement path in an open-plan office,

where workstations and other furniture are present. Position of the OSS is in the end of a path.

If the measurements are conducted in an open-plan office where the workstations and other furniture

have not yet been installed, the number of measurement positions and positions of both OSS and

microphone shall the same as above. The measurement positions shall be chosen using typical mutual

workstation distances. The measurement positions could be located, e.g., at distances 1,0 m, 2,5 m,

5,0 m, 7,5 m, 10,0 m, 12,5 m, 15,0 m, and 17,5 m from the OSS.
4.2.4 Measurement quantities
At every measurement position, four measurements or determinations are made:
— distance to the OSS disregarding the obstacles, r;
— unweighted SPL of wide-band noise caused by the OSS, L ;
p,oss
— unweighted SPL of background noise, L ;
p,B
— STI;

The accuracy of distance measurement shall be less than 0,10 m. Distances should be based on physical

measurements on site. A laser distance meter is preferred. If the distance cannot be measured due to

e.g. obstacles on measurement path, and the distances must be based on layout drawings, the accuracy

of these drawings (open-plan office dimensions, furniture positions) shall be confirmed by physical

measurements on site.

The distance means the straight distance from the midpoint of the OSS to the midpoint of the

microphone.
© ISO 2021 – All rights reserved 5
---------------------- Page: 10 ----------------------
ISO/DIS 3382-3:2021(E)

L and L are measured in octave bands within 125 Hz to 8 000 Hz. The integration time shall be at

p,oss p,B
least 10 s.

NOTE Integration times longer than 10 s are needed for transient background noise, e.g. traffic noise.

5 Determination of single-number quantities
5.1 Spectrum of normal speech

The sound power level (SWL) of normal effort speech is used. The octave band values represent normal

effort unisex speech (average of female and male speech). The octave band SPL at a distance of 1,0 m

from the middle point of the OSS in the free field (L ) is presented in Table 1. The SWL of normal

p,S,1m,ff

effort speech is related to the SPL of speech at the distance of 1,0 m in free field by L = L + 11 dB.

W,S p,S,1m,ff

Since the OSS is used in all measurements, the SPL at the distance of 1,0 m from the OSS represent the

average sound radiation in all directions from the OSS.

Table 1 — The unweighted SPL of directional and omnidirectional speech at a distance of 1,0 m

from the speaker in free field and the corresponding SWL of speech. A-weighting is needed in

formula (5).
Band No. Frequency SPL of speech SPL of speech SWL of speech A-weighting
directional omnidirectional
i f L L L A
p,S,1m,ff p,S,1m,ff W,S
Hz dB re 20 μPa dB re 20 μPa dB re 1 pW dB
1 125 51,2 49,9 60,9 -16,1
2 250 57,2 54,3 65,3 -8,6
3 500 59,8 58,0 69,0 -3,2
4 1 000 53,5 52,0 63,0 0,0
5 2 000 48,8 44,8 55,8 1,2
6 4 000 43,8 38,8 49,8 1,0
7 8 000 38,6 33,5 44,5 -1,1
A-weighted 59,5 57,4 68,4

NOTE The SPL of directional speech within 250–8000 Hz is based on ANSI S3.5 [8]. The value at 125 Hz has

been chosen to be 6 dB under the SPL at 250 Hz. The SPL of omnidirectional speech is derived in [9] assuming the

directivity pattern of speech reported in [10]. Both directional and omnidirectional sources produce the same SWL.

5.2 Spatial decay rate of speech
5.2.1 Conventional method

Conventional method is based on the measurements of SPL produced by a calibrated OSS (abbreviated

by “oss” in related subindex). The SWL of the OSS producing wide-band noise shall be sufficiently high

in each octave band so that the SPL exceeds the background noise level at least by 6 dB at the most

distant measurement position. The SWL shall be greater than L of Table 1 to fulfil this requirement.

W,S
The spectrum shape is not required to follow the shape of L in Table 1.
W,S

The SWL of the OSS producing wide-band noise, L , is determined using a measurement standard

W,oss

having at least engineering grade accuracy. An overview of appropriate methods is given in ISO 3740.

The determination shall be made using the specified sound power level which is applied in the open-

plan office. The outcome is the calibrated SWL of the OSS. The calibrated value is associated with

specific settings of all apparatus related to the OSS.
6 © ISO 2021 – All rights reserved
---------------------- Page: 11 ----------------------
ISO/DIS 3382-3:2021(E)

The SPL at a distance of 1,0 m from the middle point of the OSS in free field, L [dB] is calculated

p,oss,1m,ff
according to formula (1)
 
LL=+10⋅lg ≈−L 11 (1)
 
pi,,ossm1 , ff, Wi,,oss, Wioss,
 2 
41π× ,0
 
where
L is the calibrated sound power level of the OSS in octave bands;
W,oss,i
i denotes the octave band.

In an open-plan office, the calibrated OSS is placed in a selected source position and the SPL produced by

the calibrated OSS, L , is determined in the N measurement positions located on the measurement

p,oss,n,i
path. The attenuation D , in decibels, of
...

PROJET DE NORME INTERNATIONALE
ISO/DIS 3382-3
ISO/TC 43/SC 2 Secrétariat: DIN
Début de vote: Vote clos le:
2021-01-29 2021-04-23
Acoustique — Mesurage des paramètres acoustiques des
salles —
Partie 3:
Bureaux ouverts
Acoustics — Measurement of room acoustic parameters —
Part 3: Open plan offices
ICS: 91.120.20
CE DOCUMENT EST UN PROJET DIFFUSÉ POUR
OBSERVATIONS ET APPROBATION. IL EST DONC
SUSCEPTIBLE DE MODIFICATION ET NE PEUT

Le présent document est distribué tel qu’il est parvenu du secrétariat du comité.

ÊTRE CITÉ COMME NORME INTERNATIONALE
AVANT SA PUBLICATION EN TANT QUE TELLE.
OUTRE LE FAIT D’ÊTRE EXAMINÉS POUR
ÉTABLIR S’ILS SONT ACCEPTABLES À DES
FINS INDUSTRIELLES, TECHNOLOGIQUES ET
COMMERCIALES, AINSI QUE DU POINT DE VUE TRAITEMENT PARALLÈLE ISO/CEN
DES UTILISATEURS, LES PROJETS DE NORMES
INTERNATIONALES DOIVENT PARFOIS ÊTRE
CONSIDÉRÉS DU POINT DE VUE DE LEUR
POSSIBILITÉ DE DEVENIR DES NORMES
POUVANT SERVIR DE RÉFÉRENCE DANS LA
RÉGLEMENTATION NATIONALE.
Numéro de référence
LES DESTINATAIRES DU PRÉSENT PROJET
ISO/DIS 3382-3:2021(F)
SONT INVITÉS À PRÉSENTER, AVEC LEURS
OBSERVATIONS, NOTIFICATION DES DROITS
DE PROPRIÉTÉ DONT ILS AURAIENT
ÉVENTUELLEMENT CONNAISSANCE ET À
FOURNIR UNE DOCUMENTATION EXPLICATIVE. ISO 2021
---------------------- Page: 1 ----------------------
ISO/DIS 3382-3:2021(F)
ISO/DIS 3382-3:2021(F)
Sommaire ƒ‰‡

Avant-propos...........................................................................................................................................................iv

Introduction ............................................................................................................................................................vi

1 Domaine d’application ............................................................................................................................. 1

2 Références normatives ............................................................................................................................ 1

3 Termes et définitions ............................................................................................................................... 1

4 Conditions de mesurage .......................................................................................................................... 3

4.1 Équipement ................................................................................................................................................. 3

4.2 Mode opératoire de mesurage ............................................................................................................... 4

4.2.1 Conditions de mesurage .......................................................................................................................... 4

4.2.2 Zones acoustiques de la salle ................................................................................................................. 4

4.2.3 Positions de la source et des microphones ........................................................................................ 4

4.2.4 Grandeurs de mesurage .......................................................................................................................... 6

5 Détermination des grandeurs exprimées en valeurs uniques ..................................................... 6

5.1 Spectre de la parole à effort normal .................................................................................................... 6

5.2 Taux de décroissance spatiale de la parole ....................................................................................... 7

5.2.1 Méthode conventionnelle ....................................................................................................................... 7

5.2.2 Méthode de la réponse impulsionnelle ............................................................................................ 10

5.3 Niveau de la parole à une distance de 4 m ...................................................................................... 10

5.4 Bruit de fond ............................................................................................................................................ 10

5.5 Indice de transmission de la parole .................................................................................................. 11

5.6 Distances de confort et de distraction .............................................................................................. 12

5.7 Valeurs types des grandeurs exprimées en valeurs uniques ..................................................... 13

6 Fidélité ...................................................................................................................................................... 13

7 Rapport d’essai ....................................................................................................................................... 13

Annexe A (informative) Paramètres psychologiques de la distance de distraction ........................ 15

Annexe B (informative) Autres méthodes permettant de déterminer le taux de décroissance

spatiale ...................................................................................................................................................... 16

Annexe C (informative) Exemples de valeurs types pour les grandeurs exprimées en valeurs

uniques ...................................................................................................................................................... 19

Annexe D (informative) Exactitude ............................................................................................................... 20

Bibliographie ........................................................................................................................................................ 21

DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2021

Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en oeuvre, aucune partie de cette

publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,

y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut

être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.

ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
̹ ʹͲʹͳ–‘—•†”‘‹–•”±•‡”˜±•
Website: www.iso.org ‹‹‹
Publié en Suisse
ii © ISO 2021 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO/DIS 3382-3:2021(F)
Sommaire Page

Avant-propos...........................................................................................................................................................iv

Introduction ............................................................................................................................................................vi

1 Domaine d’application ............................................................................................................................. 1

2 Références normatives ............................................................................................................................ 1

3 Termes et définitions ............................................................................................................................... 1

4 Conditions de mesurage .......................................................................................................................... 3

4.1 Équipement ................................................................................................................................................. 3

4.2 Mode opératoire de mesurage ............................................................................................................... 4

4.2.1 Conditions de mesurage .......................................................................................................................... 4

4.2.2 Zones acoustiques de la salle ................................................................................................................. 4

4.2.3 Positions de la source et des microphones ........................................................................................ 4

4.2.4 Grandeurs de mesurage .......................................................................................................................... 6

5 Détermination des grandeurs exprimées en valeurs uniques ..................................................... 6

5.1 Spectre de la parole à effort normal .................................................................................................... 6

5.2 Taux de décroissance spatiale de la parole ....................................................................................... 7

5.2.1 Méthode conventionnelle ....................................................................................................................... 7

5.2.2 Méthode de la réponse impulsionnelle ............................................................................................ 10

5.3 Niveau de la parole à une distance de 4 m ...................................................................................... 10

5.4 Bruit de fond ............................................................................................................................................ 10

5.5 Indice de transmission de la parole .................................................................................................. 11

5.6 Distances de confort et de distraction .............................................................................................. 12

5.7 Valeurs types des grandeurs exprimées en valeurs uniques ..................................................... 13

6 Fidélité ...................................................................................................................................................... 13

7 Rapport d’essai ....................................................................................................................................... 13

Annexe A (informative) Paramètres psychologiques de la distance de distraction ........................ 15

Annexe B (informative) Autres méthodes permettant de déterminer le taux de décroissance

spatiale ...................................................................................................................................................... 16

Annexe C (informative) Exemples de valeurs types pour les grandeurs exprimées en valeurs

uniques ...................................................................................................................................................... 19

Annexe D (informative) Exactitude ............................................................................................................... 20

Bibliographie ........................................................................................................................................................ 21

© ISO 2021 – Tous droits réservés
iii
---------------------- Page: 3 ----------------------
ISO/DIS 3382-3:2021(F)
Avant-propos

L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes

nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est en

général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude a le droit

de faire partie du comité technique créé à cet effet. Les organisations internationales, gouvernementales

et non gouvernementales, en liaison avec l’ISO participent également aux travaux. L’ISO collabore

étroitement avec la Commission électrotechnique internationale (IEC) en ce qui concerne la

normalisation électrotechnique.

Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont

décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents

critères d’approbation requis pour les différents types de documents ISO. Le présent document a été

rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2

(voir www.iso.org/directives).

L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de

droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de

ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant les

références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de l’élaboration

du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de brevets reçues par

l’ISO (voir www.iso.org/brevets).

Les appellations commerciales éventuellement mentionnées dans le présent document sont données

pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un

engagement.

Pour une explication de la nature volontaire des normes, la signification des termes et expressions

spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion

de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles

techniques au commerce (OTC), voir le lien suivant : www.iso.org/iso/fr/avant-propos.

Le présent document a été élaboré par le comité technique [ou comité de projet] ISO/TC 43, Acoustique,

sous-comité SC 2, Acoustique des bâtiments.

Cette deuxième édition annule et remplace la première édition (ISO 3382-3:2012), qui a fait l’objet d’une

révision technique. Les principales modifications par rapport à l’édition précédente sont les suivantes :

— ajout de nouvelles grandeurs exprimées en valeurs uniques et d’une distance de confort, et suppression

de la distance de confidentialité ;
— insistance sur l’utilisation d’une source sonore omnidirectionnelle ;
— clarification des conditions de mesurage (Article 4) ;

— clarification de la détermination des grandeurs exprimées en valeurs uniques (Article 5) ;

— description plus précise de l’utilisation de la méthode de la réponse impulsionnelle, et ajout d’une

nouvelle annexe ;
— ajout de l’Article 6 Fidélité et de l’annexe informative Exactitude ;

— détermination de l’indice de transmission de la parole (STI) conformément à l’IEC 20268-16 à l’aide

des facteurs de pondération α et β pour les hommes.
© ISO 2021 – Tous droits réservés
---------------------- Page: 4 ----------------------
ISO/DIS 3382-3:2021(F)

Une liste de toutes les parties de la série ISO 3382 se trouve sur le site web de l’ISO.

Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent

document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes

se trouve à l’adresse www.iso.org/fr/members.html.
© ISO 2021 – Tous droits réservés
---------------------- Page: 5 ----------------------
ISO/DIS 3382-3:2021(F)
Introduction

Le bruit et le manque de confidentialité des conversations sont parmi les facteurs environnementaux qui

créent le plus d’insatisfaction dans les bureaux ouverts [1]. Les conversations des collègues constituent

la principale source de bruit. La perception du bruit et le manque de confidentialité des conversations

s’expliquent, entre autres, par une mauvaise conception acoustique des bureaux. La distraction due aux

conversions environnantes diminue les capacités de concentration et réduit la productivité, en particulier

pour les tâches qui nécessitent des capacités cognitives. Le manque d’isolement empêche de mener des

conversations confidentielles. Plusieurs études expérimentales suggèrent qu’une diminution de

l’intelligibilité de la parole peut améliorer l’attention [2,3], et une vaste étude in situ confirme que

l’intelligibilité réduite de la parole est associée à une perturbation sonore réduite [4].

La présente partie de l’ISO 3382 spécifie une méthode de mesurage, qui donne un groupe de grandeurs

exprimées en valeurs uniques indiquant la performance acoustique d’un bureau ouvert lorsqu’une

personne parle. Ces grandeurs sont centrées sur le taux de décroissance spatiale de la parole, tandis que

celles de la Partie 2 de la norme concernent le taux de décroissance temporelle du son.

Le concept de « bureaux ouverts » désigne de vastes espaces de travail dans lesquels un grand nombre

de personnes peuvent travailler à des postes de travail définis. Les bureaux flexibles ainsi que les espaces

de travail organisés par pôles d’activité sont des exemples de ce concept. Les bureaux ouverts peuvent

également être des lieux tels que des bibliothèques, des services au sein d’un hôpital, des locaux

industriels et des établissements scolaires. Conformément à la Référence [4], nombre de grandeurs

exprimées en valeurs uniques indiquées dans la présente norme sont associées à la perturbation sonore

perçue dans des bureaux ouverts.

La qualité acoustique d’une salle peut être affectée par le nombre et le positionnement des matériaux

absorbants, la géométrie de la salle, les postes de travail, les écrans et autre mobilier, ainsi que le niveau

de bruit de fond, c’est-à-dire le masquage sonore. La littérature actuelle [5,6,7] explique comment

il convient de concevoir l’acoustique d’une salle pour atteindre une qualité acoustique appropriée telle

que définie dans la présente norme.

La méthode décrit la performance acoustique d’un bureau ouvert dans une situation normalisée dans

laquelle une seule personne parle avec un niveau d’effort normal. Le bruit de fond dû aux équipements

du bâtiment ou au masquage électronique est pris en compte. Les mesurages sont réalisés dans un bureau

ouvert non occupé car la méthode concerne les propriétés permanentes du bâtiment, les conditions

acoustiques stables de la salle comme c’est aussi le cas pour les Parties 1 et 2 de la présente norme. Les

conditions sonores réelles lorsque l’espace est occupé n’entrent pas dans le domaine d’application de la

présente norme. Bien que le bruit des activités des occupants du lieu puisse être significativement plus

fort que le bruit de fond émanant des équipements du bâtiment ou du masquage sonore, le bruit des

activités est hors du domaine d’application de la présente norme. De même, la présentation des lignes

directrices pour la conception acoustique n’entre pas dans le domaine d’application de l’ISO 3382-3.

© ISO 2021 – Tous droits réservés
---------------------- Page: 6 ----------------------
PROJET DE NORME INTERNATIONALE ISO/DIS 3382-3:2021(F)
Acoustique — Mesurage des paramètres acoustiques
des salles — Partie 3 : Bureaux ouverts
1 Domaine d’application

Le présent document spécifie les méthodes de mesurage des paramètres acoustiques des salles dans des

bureaux ouverts non occupés. Il décrit les modes opératoires de mesurage, l’appareillage nécessaire, la

couverture requise, la méthode d’évaluation des données et la présentation du rapport d’essai.

2 Références normatives

Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur

contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique.

Pour les références non datées, la dernière édition du document de référence s’applique (y compris les

éventuels amendements).

ISO 3382-1, Acoustique — Mesurage des paramètres acoustiques des salles — Partie 1 : Salles de spectacles.

ISO 3740, Acoustique — Détermination des niveaux de puissance acoustique émis par les sources de bruit —

Lignes directrices pour l’utilisation des normes de base.

IEC 60268-16:2011, Équipements pour systèmes électroacoustiques — Partie 16 : Évaluation objective de

l’intelligibilité de la parole au moyen de l’indice de transmission de la parole.

IEC 60942, Électroacoustique — Calibreurs acoustiques.

IEC 61260, Électroacoustique — Filtres de bande d’octave et de bande d’une fraction d’octave.

IEC 61672-1, Électroacoustique — Sonomètres — Partie 1 : Spécifications.
3 Termes et définitions

Pour les besoins du présent document, les termes et définitions suivants s’appliquent.

L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en

normalisation, consultables aux adresses suivantes :

— ISO Online browsing platform : disponible à l’adresse https://www.iso.org/obp ;

— IEC Electropedia : disponible à l’adresse http://www.electropedia.org/.
3.1
source sonore omnidirectionnelle
OSS
source sonore qui émet un son de façon uniforme dans toutes les directions
© ISO 2020 – Tous droits réservés
---------------------- Page: 7 ----------------------
ISO/DIS 3382-3:2021(F)
3.2
décroissance spatiale du niveau de pression acoustique pondéré A de la parole

courbe de décroissance du niveau de pression acoustique (SPL) pondéré A en fonction de la distance du

centre de la source sonore omnidirectionnelle émettant un bruit avec un niveau de puissance acoustique

de la parole normale compris entre 125 Hz et 8 000 Hz
3.3
taux de décroissance spatiale de la parole
2,S

taux de décroissance spatiale du niveau de pression acoustique pondéré A de la parole par doublement

de distance en décibels

Note 1 à l’article : Cette grandeur décrit la rapidité avec laquelle le niveau de pression acoustique pondéré A de la

parole est atténué dans un bureau ouvert lorsque l’on s’éloigne de la source. Une valeur élevée indique une forte

atténuation acoustique globale de la salle. En champ libre, D = 6 dB.
2,S
3.4
niveau de la parole à une distance de 4 m
p,A,S,4m

niveau nominal de pression acoustique pondéré A, en décibels, à une distance de 4,0 m du centre de la

source sonore omnidirectionnelle émettant un bruit avec un niveau de puissance acoustique de la parole

normale compris entre 125 Hz et 8 000 Hz

Note 1 à l’article : Cette grandeur décrit le niveau de pression acoustique pondéré A de la parole à une distance

dans laquelle se trouve presque toujours le poste de travail le plus proche. Une valeur faible indique une forte

atténuation acoustique de la salle à proximité de la source sonore omnidirectionnelle.

3.5
distance de confort

distance du locuteur, en mètres, à laquelle le niveau de pression acoustique pondéré A passe au-dessous

de 45 dB lorsque la source sonore omnidirectionnelle émet un bruit avec un niveau de puissance

acoustique de la parole normale compris entre 125 Hz et 8 000 Hz

Note 1 à l’article : La distance de confort diminue lorsque D2,S augmente et Lp,A,S,4m baisse.

3.6
niveau de bruit de fond
p,B

niveau moyen de pression acoustique non pondéré du bruit de fond, en décibels, mesuré aux postes de

travail le long de la trajectoire de mesurage pendant les heures de travail et en l’absence des occupants

Note 1 à l’article : Le bruit de fond est mesuré en bandes d’octave comprises entre 125 Hz et 8 000 Hz.

3.7
indice de transmission de la parole
STI

valeur proportionnelle représentant la qualité de transmission de la parole. L’indice de transmission de

la parole a une valeur comprise entre 0,00 et 1,00
[SOURCE : IEC 60268-16:2011]

Note 1 à l’article : La valeur de l’indice de transmission de la parole est associée l’intelligibilité subjective de la

parole.
© ISO 2021 – Tous droits réservés
---------------------- Page: 8 ----------------------
ISO/DIS 3382-3:2021(F)
3.8
décroissance spatiale de l’indice de transmission de la parole

courbe de décroissance de l’indice de transmission de la parole en fonction de la distance à la source

sonore omnidirectionnelle
3.9
distance de distraction

distance depuis la source sonore omnidirectionnelle, en mètres, lorsque l’indice de transmission de la

parole passe au-dessous de 0,50

Note 1 à l’article : La distance de distraction diminue lorsque rC baisse et Lp,B augmente. Une valeur faible indique

une confidentialité élevée de la parole. Lorsque le locuteur se trouve au-delà de la distance de distraction de

l’occupant, ce dernier a un meilleur rendement au travail qu’à des distances plus courtes (voir Annexe A).

3.10
poste de travail

ensemble de mobilier comprenant un fauteuil ergonomique réglable et une table de travail mesurant au

minimum 70 cm x 70 cm. La hauteur du plateau peut être ajustée à une hauteur de 75 cm du sol. Le poste

de travail peut inclure d’autres composants, tels qu’un ou plusieurs écrans, une ou plusieurs unités de

stockage, des dispositifs d’affichage ou un luminaire
4 Conditions de mesurage
4.1 Équipement

4.1.1 Source sonore. Une source sonore omnidirectionnelle (OSS) doit être utilisée pour tous les

mesurages. Ce type de source est utilisé car les occupants d’un bureau ouvert ne parlent pas dans une

direction précisément déterminée. Les exigences de l’ISO 3382-1 concernant la source sonore

omnidirectionnelle entre 125 Hz et 4 000 Hz doivent être respectées pour les mesurages effectués

conformément à la présente partie de l’ISO 3382.
NOTE Aucune exigence ne s’applique à la bande d’octave 8 000 Hz.

4.1.2 Microphone. Les niveaux de pression acoustique dans chaque bande d’octave et à chaque

position de microphone doivent être mesurés au moyen d’un sonomètre satisfaisant aux exigences pour

les équipements de classe 1 données dans l’IEC 61672-1. Le microphone doit être omnidirectionnel, en

prenant en compte tout équipement supplémentaire connecté.

4.1.3 Analyseur. Les filtres de bande d’octave de l’analyseur ou du logiciel d’analyse doivent être

conformes à l’IEC 61260. Si le signal est enregistré, au moyen par exemple d’enregistreurs analogiques

ou numériques pour le traitement en différé, il faut veiller à ce que l’ensemble de l’appareillage soit

conforme aux exigences mentionnées ci-dessus.

4.1.4 Calibreur. Avant et après chaque série de mesurages, la sensibilité acoustique du système de

mesurage doit être vérifiée au moyen d’un calibreur acoustique conforme à l’IEC 60942. Les résultats des

vérifications réalisées avec un calibreur doivent être documentés. Si les résultats obtenus divergent de

plus de 0,5 dB, les mesurages doivent être répétés. Il est recommandé de procéder à ces vérifications

à chaque remplacement de batteries ou à chaque modification du bureau ouvert.
© ISO 2021 – Tous droits réservés
---------------------- Page: 9 ----------------------
ISO/DIS 3382-3:2021(F)
4.2 Mode opératoire de mesurage
4.2.1 Conditions de mesurage

Les mesurages peuvent être réalisés dans des bureaux ouverts de tout type, quelle que soit leur

configuration en termes de matériaux absorbants pour plafond et murs, systèmes de masquage sonore,

revêtements de sol, cloisons fixes, postes de travail, écrans, unités de stockage et autre mobilier fixe ou

mobile. Les résultats ne sont valides que pour la configuration spécifiée présente au moment du

mesurage. Il est donc important de minutieusement consigner ces facteurs avec les résultats des

mesurages.

Le bruit de fond désigne tous les bruits stationnaires présents pendant les heures de travail normales et

non générés par les occupants. Il s’agit, par exemple, des bruits engendrés par les systèmes de chauffage,

ventilation et climatisation (HVAC), du bruit ambiant provenant de sources extérieures au bâtiment,

ou encore du bruit provenant d’un système de masquage sonore.

Les systèmes HVAC doivent fonctionner à la même puissance que pendant les heures de travail normales.

Si le bureau est équipé d’un système de masquage sonore, celui-ci doit être activé pendant le mesurage.

Le masquage sonore doit fonctionner au même niveau et avec le même spectre que pendant les heures

de travail normales. Il convient que les systèmes de masquage adaptatifs soient soumis à des essais

distincts pour les niveaux minimums et maximums. Les équipements tels que réfrigérateurs,

imprimantes, machines à café, radios et projecteurs vidéo doivent être éteints s’ils augmentent le bruit

de fond en un point de mesurage quelconque. Les fenêtres et portes-fenêtres doivent être fermées. Tous

les mesurages doivent être réalisés en l’absence des occupants. Seul le technicien chargé des mesurages

peut être présent dans le bureau ouvert.

Si les hauteurs de table sont électriquement réglables, la hauteur de plateau est réglée à (75 ± 5) cm du

sol pour les postes de travail situés dans la trajectoire de mesurage.
4.2.2 Zones acoustiques de la salle

Si les bureaux ouverts peuvent comprendre deux zones ou plus dont le traitement d’absorption

acoustique et/ou l’agencement du mobilier diffèrent, les mesurages doivent être réalisés dans chaque

zone et les grandeurs exprimées en valeurs uniques sont déterminées et consignées pour chacune des

zones séparément.

Au moins deux trajectoires de mesurage distinctes doivent être utilisées par zone de bureau ouvert.

Si une seule trajectoire est possible, réaliser les mesurages dans les deux directions le long de la même

trajectoire de mesurage.
4.2.3 Positions de la source et des microphones

Les mesurages doivent être réalisés sur une trajectoire la plus droite possible passant au-dessus des

postes de travail, comme illustré à la Figure 1.

Si la zone comporte du mobilier courant (généralement écran ou unité de stockage) entre les postes de

travail, il convient de choisir la trajectoire de mesurage de sorte qu’il y ait un obstacle entre la source

sonore omnidirectionnelle et le premier point de mesurage.

La source sonore omnidirectionnelle se trouve au poste de travail situé à une extrémité de la trajectoire.

Elle doit êt
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.