Gullies for buildings - Part 5: Gullies with light liquids closure

This draft European Standard specifies requirements for the design, construction, performance, application and marking as well as test methods of factory made gullies with a light liquid closure for buildings.
Light liquid closures for buildings shall be applied to avoid uncontrolled discharge of light liquids into drainage systems in case of emergency.
This draft European Standard does not apply to installations for separation of light liquids covered by EN 858-1.

Abläufe für Gebäude - Teil 5: Abläufe mit Leichtflüssigkeitssperren

Diese Europäische Norm legt Anforderungen an die Ausführung, Konstruktion, Funktion, Anwendung und Kennzeichnung sowie Prüfverfahren für werkmäßig hergestellte Abläufe mit Leichtflüssigkeitssperre für Gebäude fest.
Leichtflüssigkeitssperren für Gebäude müssen eingesetzt werden, um im Notfall das unkontrollierte Ableiten von Leichtflüssigkeiten in die Entwässerungsanlage zu verhindern.
Diese Norm gilt nicht für Abscheideranlagen für Leichtflüssigkeiten nach EN 858-1.

Avaloirs et siphons pour bâtiments - Partie 5 : Siphons avec obturateur pour liquides légers

Le présent projet de Norme européenne spécifie des exigences relatives à la conception, à la fabrication, aux performances, à l'installation, au marquage ainsi que les méthodes d'essai applicables aux siphons avec obturateur pour liquides légers fabriqués en usine et destinés aux bâtiments.
Les obturateurs pour liquides légers destinés aux bâtiments doivent être utilisés pour éviter tout rejet non maîtrisé de liquides légers dans les réseaux d'évacuation en cas d'urgence.
Le présent projet de Norme européenne n'est pas applicable aux installations de séparation des liquides légers telles que spécifiées dans l'EN 858-1.

Odtoki v stavbah - 5. del: Odtoki z zaporo lahkih tekočin

Ta osnutek evropskega standarda določa zahteve za načrtovanje, izdelavo, učinkovitost, uporabo in označevanje ter preskusne metode za tovarniško izdelane odtoke z zaporo lahkih tekočin za stavbe.
Zaporo lahkih tekočin za stavbe je treba uporabiti za preprečevanje nenadzorovanega izpusta lahkih tekočin v kanalizacijske sisteme v nujnih primerih.
Ta osnutek evropskega standarda se ne uporablja za naprave za ločevanje lahkih tekočin, zajete v standardu EN 858-1.

General Information

Status
Published
Public Enquiry End Date
29-Oct-2015
Publication Date
27-Feb-2017
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
21-Feb-2017
Due Date
28-Apr-2017
Completion Date
28-Feb-2017

Relations

Overview

SIST EN 1253-5:2017 is a European Standard developed by CEN that specifies the requirements for factory-made gullies with light liquid closures used in buildings. These gullies are designed to prevent the uncontrolled discharge of light liquids-such as petrol, diesel, or fuel oil-into drainage systems during emergencies. The standard covers the design, construction, performance, application, marking, and test methods for such gullies, ensuring safety and environmental protection in building drainage systems.

This standard excludes installations intended for the separation of light liquids, which are addressed by EN 858-1. SIST EN 1253-5:2017 forms part of the EN 1253 series, focusing exclusively on gullies with light liquid closure to enhance drainage safety in buildings where light liquid contamination risk exists.

Key Topics

  • Scope and Application
    EN 1253-5 targets gullies equipped with devices that automatically close when a certain level of light liquid is detected, preventing it from entering sewage and drainage systems.

  • Types of Gullies

    • Type A: Gullies with integrated light liquid closure suitable for unlimited use in gravity drainage systems.
    • Type B: Gullies where the light liquid closure is an accessory, allowing a reduction in flow rate for specific applications.
  • Materials
    Components in contact with light liquids or wastewater must be resistant to degradation, ensuring long-term durability and safety.

  • Design and Construction Requirements

    • Inflow is only permitted through a grating on top of the gully, prohibiting inlets that might compromise the closure device.
    • The closure device must maintain a security height of at least 30 mm between the sealing and the separation line for water and light liquid.
    • Tightness requirements enforce leakage to be less than 0.1 liters per hour under test conditions.
    • Closure units should be easily removable for maintenance.
  • Flow Rates
    Minimum flow rates are specified based on the nominal diameter of the gully outlet, ensuring efficient drainage without compromising the closure’s function.

  • Test Methods
    Includes assessments for closure ability, tightness, and security height, ensuring compliance with performance standards.

  • Marking and Identification
    Each gully and its components must bear clear, durable markings including standard reference, manufacturer details, manufacture date, certification, and product specifications for traceability and verification.

Applications

SIST EN 1253-5:2017 is essential for:

  • Building drainage systems where light liquids might accidentally enter the sewage network, such as in commercial garages, fuel stations, industrial facilities, and residential buildings.
  • Safety installations preventing environmental contamination by automatically sealing off light liquid spills from entering drainage infrastructure.
  • Planners and engineers specifying compliant gullies to meet regulatory and environmental protection requirements.
  • Manufacturers designing and producing gullies that comply with rigorous European standards for safety, performance, and durability.
  • Maintenance personnel ensuring proper servicing through easy removal features of closure devices as mandated by the standard.

Related Standards

  • EN 1253-1:2015 – Specifies requirements for trapped floor gullies with a water seal of at least 50 mm, forming the foundational part of the EN 1253 series.
  • EN 1253-3 – Provides guidelines for the evaluation of conformity related to gullies covered in this series.
  • EN 858-1 – Covers separator systems for light liquids, focusing on product design, performance, and testing of light liquid separators, which are outside the scope of EN 1253-5.

By adhering to SIST EN 1253-5:2017, stakeholders ensure optimal design and safe operation of gullies with light liquid closures, protecting drainage systems from hazardous liquid discharge and contributing to sustainable wastewater management in buildings.

Standard
SIST EN 1253-5:2017
English language
9 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Abläufe für Gebäude - Teil 5: Abläufe mit LeichtflüssigkeitssperrenAvaloirs et siphons pour bâtiments - Partie 5 : Siphons avec obturateur pour liquides légersGullies for buildings - Part 5: Gullies with light liquids closure91.140.80Drenažni sistemiDrainage systemsICS:Ta slovenski standard je istoveten z:EN 1253-5:2017SIST EN 1253-5:2017en,fr,de01-april-2017SIST EN 1253-5:2017SLOVENSKI
STANDARDSIST EN 1253-5:20041DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1253-5
February
t r s y ICS
{ sä s v rä z r Supersedes EN
s t w uæ wã t r r uEnglish Version
Gullies for buildings æ Part
wã Gullies with light liquids closure Avaloirs et siphons pour bâtiments æ Partie
w ã Siphons avec obturateur pour liquides légers
Abläufe für Gebäude æ Teil
wã Abläufe mit Leichtflüssigkeitssperren This European Standard was approved by CEN on
s v December
t r s xä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s t w uæ wã t r s y ESIST EN 1253-5:2017
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

SIST EN 1253-5:2017 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Gullies for buildings - Part 5: Gullies with light liquids closure". This standard covers: This draft European Standard specifies requirements for the design, construction, performance, application and marking as well as test methods of factory made gullies with a light liquid closure for buildings. Light liquid closures for buildings shall be applied to avoid uncontrolled discharge of light liquids into drainage systems in case of emergency. This draft European Standard does not apply to installations for separation of light liquids covered by EN 858-1.

This draft European Standard specifies requirements for the design, construction, performance, application and marking as well as test methods of factory made gullies with a light liquid closure for buildings. Light liquid closures for buildings shall be applied to avoid uncontrolled discharge of light liquids into drainage systems in case of emergency. This draft European Standard does not apply to installations for separation of light liquids covered by EN 858-1.

SIST EN 1253-5:2017 is classified under the following ICS (International Classification for Standards) categories: 91.140.80 - Drainage systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 1253-5:2017 has the following relationships with other standards: It is inter standard links to SIST EN 1253-5:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase SIST EN 1253-5:2017 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.