SIST EN 14897:2006+A1:2007
(Main)Water conditioning equipment inside buildings - Devices using mercury low-pressure ultraviolet radiators - Requirements for performance, safety and testing
Water conditioning equipment inside buildings - Devices using mercury low-pressure ultraviolet radiators - Requirements for performance, safety and testing
This document specifies definitions, principles of construction, requirements and methods for testing the performance of UV devices for drinking water installations inside buildings which are permanently connected to the mains supply at the point of entry into a building or within the water distribution system inside the building.
UV devices in the sense of this standard are UV bactericidal treatment devices or UV disinfection devices.
Anlagen zur Behandlung von Trinkwasser innerhalb von Gebäuden - Geräte mit Quecksilberdampf-Niederdruckstrahlern - Anforderungen an Ausführung, Sicherheit und Prüfung
Dieses Dokument legt Begriffe, Grundsätze der Konstruktion, Anforderungen und Verfahren für die Prüfung der Leistungsanforderungen von UV-Geräten für Trinkwasserinstallationen innerhalb von Gebäuden, die fest am Eintrittspunkt des Wassers in die Hausinstallation angeschlossen oder in die weitere Installation integriert sind, fest.
UV-Geräte im Sinne dieser Norm sind UV-Geräte zur antibakteriellen Behandlung oder UV-Desinfektions-geräte.
Appareils de traitement d'eau a l'intérieur des bâtiments - Dispositifs utilisant des radiateurs a mercure et basse pression de rayonnement UV - Exigences de performance, de sécurité et essais
Oprema, ki se uporablja za pripravo pitne vode v stavbah - Naprave z živosrebrnimi nizkotlačnimi ultravijoličnimi sevalniki - Zahteve za delovanje, varnost in preskušanje
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Water conditioning equipment inside buildings - Devices using mercury low-pressure ultraviolet radiators - Requirements for performance, safety and testingAppareils de traitement d'eau a l'intérieur des bâtiments - Dispositifs utilisant des radiateurs a mercure et basse pression de rayonnement UV - Exigences de performance, de sécurité et essaisAnlagen zur Behandlung von Trinkwasser innerhalb von Gebäuden - Geräte mit Quecksilberdampf-Niederdruckstrahlern - Anforderungen an Ausführung, Sicherheit und PrüfungTa slovenski standard je istoveten z:EN 14897:2006+A1:2007SIST EN 14897:2006+A1:2007en,fr91.140.60Sistemi za oskrbo z vodoWater supply systems13.060.20Pitna vodaDrinking waterICS:SLOVENSKI
STANDARDSIST EN 14897:2006+A1:200701-september-2007
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14897:2006+A1
June 2007 ICS 13.060.20; 91.140.60 SupersedesEN 14897:2006English Version
Water conditioning equipment inside buildings - Devices using mercury low-pressure ultraviolet radiators - Requirements for performance, safety and testing
Appareils de traitement d'eau à l'intérieur des bâtiments - Dispositifs utilisant des radiateurs à mercure et basse pression de rayonnement UV - Exigences de performance, de sécurité et essais
Anlagen zur Behandlung von Trinkwasser innerhalb von Gebäuden - Geräte mit Quecksilberdampf-Niederdruckstrahlern - Anforderungen an Ausführung, Sicherheit und Prüfung This European Standard was approved by CEN on 10 May 2006 and includes Amendment 1 approved by CEN on 10 May 2007.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14897:2006+A1:2007: E
EN 14897:2006+A1:2007 (E) 2 Contents Page Foreword.3 1 Scope.4 2 Normative references.4 3 Definitions.4 4 Requirements.7 4.1 General.7 4.2 Radiation chamber.7 4.3 Low-pressure mercury UV lamps.7 4.4 Electrical.7 4.4.1 General.7 4.4.2 UV disinfection devices.7 4.4.3 UV bactericidal treatment devices.8 4.5 Performance.8 4.6 Labelling.8 4.7 Manual.9 5 Testing.9 5.1 General.9 5.2 Test rig and installation.10 5.3 Biodosimetric measurements.10 5.4 Performance test procedure.11 5.4.1 UV disinfection devices.11 5.4.2 Processing of the data.13 5.4.3 UV bactericidal treatment devices.15 5.4.4 Processing of the data.15 Annex A (normative)
Requirements for the device sensor.17 A.1 Calibration.17 A.2 Selectivity.17 A.3 Measuring range linearity.17 A.4 Measuring range and resolution.17 A.5 Temperature drift.18 A.6 Stability over time.18 Annex B (normative)
Biodosimeter calibration.19 Annex C (informative)
Monitoring window.22 Annex D (normative)
Manufacturer's information for the type test.23 Annex E (normative)
Manufacturer's information for the UV device user.25 Annex F (normative)
!Installation, operation and maintenance.26 Bibliography.30
EN 14897:2006+A1:2007 (E) 3 Foreword This document (EN 14897:2006+A1:2007) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by AFNOR. This document shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2007 and conflicting national standards shall be withdrawn at the latest by December 2007. This document includes Amendment 1, approved by CEN on 2007-05-10. This document supersedes EN 14897:2006. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! ". With respect to potential adverse effects on the quality of water intended for human consumption/caused by the product covered by this standard, the following is pointed out to the user of the standard. 1) This standard provides no information as to whether the product may be used without restriction in any of the Member States. 2) It should be noted that, while awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or characteristics of this product remain in force.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EN 14897:2006+A1:2007 (E) 4 1 Scope This document specifies definitions, principles of construction, requirements and methods for testing the performance of UV devices for drinking water installations inside buildings which are permanently connected to the mains supply at the point of entry into a building or within the water distribution system inside the building. UV devices in the sense of this standard are UV bactericidal treatment devices or UV disinfection devices. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1717, Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow 3 Definitions For the purposes of this document, the following terms and definitions apply. 3.1 absorption decrease of the incident irradiance of a light beam including transformation into other forms suffered by radiant energy passing through a material substance (e. g. heat) 3.2 irradiance measure of the UV light flux divided by the area that intercepts the radiation, in W/m2
NOTE The irradiance measured in UV disinfection devices by the UV device sensor
is mainly influenced by the lamp output, the transmittance of the water, and scaling/fouling of the protective quartz sleeves and the position of the lamps in the radiation chamber. 3.3 disinfection action of killing or inactivating all types of pathogenic bacteria to a specified degree of at least 99,999 % and all types of pathogenic viruses to a degree of at least 99,99 % using a UV disinfection device 3.4 bactericidal treatment action of inactivating or killing bacteria present in water to an unspecified degree using a UV bactericidal treatment device 3.5 fluence dose product of irradiance in W/m2 and exposure time in s, in J/m2 NOTE Fluence is the correct term from a strictly scientific point of view.
3.6 germicidal fluence fluence weighted with the germicidal UV sensitivity, in J/m2
EN 14897:2006+A1:2007 (E) 5 3.7 reduction equivalent fluence (REF) average germicidal fluence measured by the biodosimeter in accordance with 5.3 in the radiation chamber, in J/m2 3.8 radiation chamber part of the device that comprises the radiation zone and the connecting pipes 3.9 radiation zone part of the radiation chamber whose volume is used for the calculation of the fluence 3.10 exposure time time interval during which a specific volume of water within the radiation zone is exposed to the radiation, in s 3.11 microbiological dosimeter; biodosimeter test organism used to determine the equivalent fluence, whose UV inactivation behaviour has been determined in a standard collimated beam apparatus (see Annex B), e. g. Bacillus subtilis spores 3.12 minimum irradiance value determined in the type test that ensures the required reduction equivalent fluence at a defined water flow rate and at a defined UV transmittance value, in W/m2 3.13 flow rate (Q) volume of water per unit time flowing through the UV device, in l/min or m3/h 3.14 maximum flow rate (Qmax) highest flow at which, at a defined UV transmittance of the water and a defined irradiance, the required reduction equivalent fluence can be guaranteed, in l/min or m3/h 3.15 permissible operation range those limit values for the operation parameters (irradiance at the sensor or UV transmittance of the water) and flow rate where adequate bactericidal treatment or disinfection is assured 3.16 sensor system for the measurement of the irradiance in UV disinfection devices 3.16.1 reference sensor sensor used to countercheck the signal of the device sensor where national regulations apply. NOTE The reference sensor should comply to national standards where existent, e.g. ![2], [3]". 3.16.2 selectivity percentage of the sensor signal that is produced by radiation with a wavelength of 254 nm 3.16.3 device sensor calibrated sensor monitoring device used for continuous measurement of the irradiance
EN 14897:2006+A1:2007 (E) 6 3.17 attenuation absorption and diffraction of radiation passing through an optical medium in a specific direction 3.18 lamp service life service life of a UV radiator after which the irradiance that is necessary to guarantee the minimum fluence can no longer be reached under the mode of operation given by the manufacturer, and the lamp has to be replaced, in h
3.19 UV lamp radiator which produces UV light 3.20 UV device general expression for products using UV light to irradiate water flow through, with the purpose of inactivating microrganisms being present in the water 3.21 UV disinfection device device designed to disinfect water 3.22 UV bactericidal treatment device device designed for bactericidal water treatment 3.23 turbidity reduction of optical transmittance of a liquid caused by the presence of undissolved matter 3.24 UV transmittance (% T100) spectral transmission rate at a wavelength of 254 nm at an optical path length in the medium of 100 mm, in % NOTE In general, the UV transmittance includes the influence of attenuation and absorption of the through passing medium. The UV transmittance is measured in the unfiltered sample in quartz cuvettes of at least 40 mm at a wavelength of 254 nm in a spectrophotometer and is given in %. 3.25 UV radiation (UV) electromagnetic radiation according to Table 1 Table 1 — UV radiation Type Wavelength nm UV-C > 100 ≤
280 UV-B > 280 ≤
315 UV-A > 315 ≤
400 NOTE
For bactericidal and disinfection purposes, part of the UV-C range is used.
EN 14897:2006+A1:2007 (E) 7 4 Requirements 4.1 General The treatment of water with the UV device shall yield a reduction equivalent fluence of at least 400 J/m2 (40 mJ/cm2), at a wavelength of 254 nm in the defined operational range. 4.2 Radiation chamber The radiation chamber is made of corrosion resistant and UV resistant materials. Materials and substances used shall be suitable for contact with drinking water.
NOTE Product intended for use in water supply systems should comply, when existing, with national regulations and testing arrangements that ensure fitness for contact with drinking water. The Member states, relevant regulators and the EC Commission agreed on the principles of a future unique European Acceptance Scheme (EAS), which would provide a common testing and approval arrangement at European level. If and when the EAS is adopted, European Product Standards will be amended by the addition of an Annex Z/EAS under Mandate M/136, which will contain formal references to the testing, certification and product marking requirements of the EAS. The mechanical design and the construction shall comply with the relevant requirements for the pressure present. Direct or indirect leaking of radiation from the radiation chamber to the environment with a wavelength below 400 nm shall be avoided. Radiation chambers shall be constructed in a way that they are easily serviceable. For UV disinfection devices, the radiation chamber shall be provided with a sensor for a representative
irradiation measurement. The location of the sensor shall be designed so that the irradiation measurement is not disturbed by gas bubbles or sediment deposits. 4.3 Low-pressure mercury UV lamps In order not to produce ozone, only lamps with a radiation range above 240 nm shall be used. !At the mercury resonance line of 254 nm shall be 85 % of the total radiation intensity in the UV-C range." Lamp(s) shall be marked with a designation of type. Only those lamps used for the type test shall be used in the UV device. The UV lamp(s) shall be approved for the device by the manufacturer or be equivalent to the approved type used at the type test. 4.4 Electrical 4.4.1 General For the electrotechnical design of UV devices, the relevant EC Directives and CE marking requirements shall be accomodated. Compliance with these EC Directives is a requirement of this standard. !deleted text" 4.4.2 UV disinfection devices 4.4.2.1 Controller The UV disinfection device shall be equipped with a controller, which provides the following functions: when switching on the device, the signal for the waterflow shall be delayed until the minimum irradiance is reached; operation and failure of the electrical function of each lamp shall be indicated; operation beyond the permissible limits of operation shall be indicated and a signal shall be provided which allows the waterflow to be stopped;
EN 14897:2006+A1:2007 (E) 8 general malfunction signal shall be provided; when shutting down the device or in case of a breakdown of the electric power supply, a signal shall be provided which allows the stop of waterflow. The following functions shall be displayed: device in function; failure signal for each lamp; irradiance, in W/m2; service time of the UV lamps;
flow-related alarm point(s). 4.4.2.2 Sensor For the measurement of the irradiation, a sensor shall be provided to ensure disinfection under consideration of possible changes in water UV transmittance and lamp performance. Requirements for the device sensor are given in Annex A. Where national regulations apply, a sensor and monitoring window may have to fulfil certain requirements. NOTE An example for a monitoring window is shown in Annex C. 4.4.3 UV bactericidal treatment devices The UV bactericidal treatment devices shall be equipped with a controller, which provides the following functions: operation and failure of the electrical function of the lamp(s) shall be indicated; general malfunction signal shall be provided. The following functions shall be displayed: device in function; service time of the UV lamps. 4.5 Performance The UV device shall apply a reduction equivalent fluence of at least 400 J/m2 at the end of the lamp service life for the specified flow rates and UV transmittance values. The performance is evaluated with a type test for which the manufacturer shall provide information in accordance with Annex D. 4.6 Labelling The information to be given on a nameplate, which shall be permanently fixed to the UV device and be legible when installed, shall be in accordance with Annex E.
EN 14897:2006+A1:2007 (E) 9 4.7 Manual The manual shall describe operation, control, cleaning and service measures. The manual shall also contain at least the following information:
operating diagram: transmittance vs. maximum admissible flow; water resulting from sampling (rinsing) shall be adequately disposed of to the provisions of EN 1717; replacement intervals for UV lamp(s), sensor (only for UV disinfection devices). 5 Testing 5.1 General The manufacturer shall provide the details and documentation described in Annex D. The device to be tested is checked for conformity to the documentation. The purpose of the type test is to verify that the UV fluence delivered by the device under test meets a reduction equivalent fluence of 400 J/m2 at the end of the lamp life, at the specified flow rates and transmittance values.
Parameters to be changed during the test are the flow rate of the water and the UV transmittance of the water for the test of UV bactericidal treatment devices and the flow rate, the transmittance and the lamp-output, for the test of UV disinfection devices. For the type test of UV disinfection devices the UV device shall be equipped with a sensor or with a specified monitoring window and a specified sensor if national regulation for these apply. The testing in the test rig comprises of five steps: checking the compliance of the device to be tested with the specifications; data collection during the test (flow rate, water temperature, electrical power consumption, .); radiation physics tests, i.e. determination of the irradiance (only for UV disinfection devices); microbiological test with the biodosimeter; evaluation of the UV device and specification of the operating range. The manufacturer shall provide data (flow rate versus UV transmittance), that give the testing points at which the UV fluence (400 J/m2) is reached at the end of the lamp service time and the percentage of UV output at the end of lamp service life (e.g. 70 %). The permissible operational range is determined by measurements of at least three test points which should cover the whole operational range.
The UV device to be tested shall have new lamps that have been in service for 100 h. The manufacturer shall provide an appropriate method to vary the output of the UV lamps.
EN 14897:2006+A1:2007 (E) 10 5.2 Test rig and installation The test rig (see Figure 1) consists of a water supply with test water, wastewater removal, electrical equipment (voltage regulator), dosing device for the biodosimeter and the transmittance reducing solution, and static mixers. The UV device is installed in the test rig and put into operation as specified by manufacturer or supplier. The UV device shall be attached to the water supply with respect to the length, configuration and nominal diameter of the inlet and outlet pipe defined by the manufacturer for the UV device. The test water shall have a UV transmittance of at least 80 % to allow the regulation of the test conditions. Calibrated registering measuring instrumentation for flow rate, pressure, water temperature, UV transmittance and electrical parameters (current voltage) are required.
Key 1 Water inlet with check valve 9 Pressure measurement device 2 Flow adjustment valve 10 Temperature measurement device 3 Dosing pump, sodium thiosulfate 11 Sampling point before UV device 4 Dosing pump, biodosimeter 12 Flowmeter 5 Sodium thiosulfate solution 13 Static mixer after UV device 6 Biodosimeter 14 Sampling point after UV device 7 Static mixer before UV device 15 Stopvalve 8 Measurement UV transmittance device in the flow Figure 1 — Test rig (schematic) 5.3 Biodosimetric measurements As soon as stable operating conditions for the test rig and the UV device at a test point are reached, the biodosimeter is added to the inlet flow. Optimum mixing is achieved by the static mixer (concentration of the biodosimeter after mixing about 106l-1
to 107 l-1). Take the samples after UV irradiation and also after a static mixer. During the test, there shall be continuous flow through the sampling ports. For each test point and measuring cycle, five samples shall be taken before and after UV irradiation respectively. The determination of the concentration of the biodosimeter as number of colony forming units (CFU) is done in triplicate using a decimal dilution series. Use the pour plate method with plate count agar. Incubate for (48 ± 4) h at (37 ± 1) °C. Use three agar plates (diameter 90 mm) of the dilution step that results in 20 to 200 colonies per plate. The arithmetric average of the three counts is multiplied by the dilution factor and converted into the decadic logarithm. This results in five lg-concentration before and five lg-concentration after UV irradiation, of which the arithmetric average is calculated (lg N0: before irradiation, lg N1: after irradiation). The standard deviation s of the five parallel samples shall not exceed ± 0,2. Otherwise the test conditions are not stable (hydraulics, dosing, mixing). By calculating lg(N/N0), the reduction at the test point is determined. In
EN 14897:2006+A1:2007 (E) 11 Table 2 an example for the calculation is given. !The conversion of the reduction to the reduction equivalent fluence is obtained using Equation B.2." Table 2 — Example for the evaluation of a biodosimetric measurement Colony counts in single petri dishes CFU Before UV Factor of dilution 1 2 3 Colony counts per litre CFU / l lg colony counts per litre lg arithmetic average before UV Sample 1 10 5 80 96 104 9,33 × 106 6,97 Sample 2 10 5 105 100 82 9,57 × 106 6,98 Sample 3 10 5 59 67 54 6,00 × 106 6,78 Sample 4 10 5 119 116 143 1,26 × 107 7,10 Sample 5 10 5 88 113 90 !9,70 ×
106" !6,99"
!6,96
± 0,14" Colony counts in single petri dishes CFU After UV Factor of dilution 1 2 3 Colony counts per litre CFU / l lg colony counts per litre lg arithmetic average
after UV Sample 1 10 3 52 37 50 4,63 × 104 4,67 Sample 2 10 3 33 53 30 3,87 × 104 4,59 Sample 3 10 3 46 55 68 5,63 × 104 4,75 Sample 4 10 3 69 74 53 6,53 × 104 4,81 Sample 5 10 3 43 34 31 3,6 × 104 4,56
4,68 ± 0,11
Reduction:
lg artihmetic average after UV – lg arithmetic average before UV !-2,28"
5.4 Performance test procedure 5.4.1 UV disinfection devices Install the UV device in the test rig. Let water flow through the UV device at the lowest flow rate to be tested for 10 min before turning on the lamps of the UV disinfection device. Turn on the UV lamp(s) and do not proceed until a stable irradiance reading is achieved.
In the first part of the test, the transmittance of the test water is varied within the operational range specified by the manufacturer that corresponds to the flow rates. The relationship of the UV transmittance of water and the irradiance measured by the sensor shall be determined. The output of the lamps is reduced by a method specified by the manufacturer, so that it is decreased to the value at the end of the lamp service time (e.g. by 30 %). The transmittance variation is done twice with three values at least. Using these six values, a graph is established as shown below.
EN 14897:2006+A1:2007 (E) 12
Key Y Irradiance E (W/m²) X UV transmittance T100 (%) Figure 2 — Irradiance measured by device sensor vs. UV transmittance From the graph the irradiance settings for the biodosimetry are derived. The following table gives an example.
Table 3 — Irradiance value settings derived from measurements during transmittance variation (example)
Irradiances E1, E2, E3 at which biodosimetric measurements take place W/m2 Maximum flow rate Q
!specified" by manufacturer m3/h UV transmittance T100 !specified" by manufacturer %/10 cm 11 3 10 31 9 50 46 12 80
The single steps to establish the transmittance-irradiance dependency are: UV transmittance of the test water is adjusted with a transmittance reducing substance [e.g. sodium thiosulfate solution (Na2S2O3)]. Adjust the UV transmittance that appertains to the highest flow rate to be tested and measure the irradiance E1. Adjust the UV transmittance that appertains to the medium flow rate to be tested and measure the irradiance E2. Adjust the UV transmittance that appertains to the lowest flow rate to be tested and measure the irradiance E3.
EN 14897:2006+A1:2007 (E) 13 The water flow rate may be kept low for these measurements (e.g. lowest flow rate to be tested), as the flow rate does not influence the measurement results. Biodosimetric measurements The UV device under test is then challenged with the biodosimeter in the test rig varying the flow rates and the irradiances first at full output of the lamp(s) and reduced UV transmittance of the test water, and second at reduced output of the lamp(s) and test water with high UV transmittance.
All measurements are repeated once with at least three test points each, divided by a shut-off of the device (shut-off of the lamp and cut-off of the water flow for 15 min). Adjust the following test points by varying the transmittance, add biodosimeter, take samples and evaluate as described above: test point 1: highest flow rate to be tested, full lamp output, adjustment of the irradiance E1 by reduction of the UV transmittance. test point 2: medium flow rate to be tested, full lamp output, adjustment of the irradiance E2 by reduction of the UV transmittance. test point 3: lowest flow rate to be tested full lamp output, adjustment of the irradiance E3 by reduction of the UV transmittance. The following test points shall be adjusted by using test water with a UV transmittance of
...