Specifications for particular types of winding wires -- Part 0-1: General requirements - Enamelled round copper wire

This part of IEC 60317 specifies general requirements of enamelled round copper winding wires with or without bonding layer. The range of nominal conductor diameters is given in the relevant specification sheet. When reference is made to a winding wire according to a standard of the IEC 60317 series mentioned under Clause 2, the following information is given in the description: - reference to IEC specification; - nominal conductor diameter in millimetres; - grade. EXAMPLE IEC 60317-1 - 0,500 Grade 2.

Technische Lieferbedingungen für bestimmte Typen von Wickeldrähten -- Teil 0-1: Allgemeine Anforderungen - Runddrähte aus Kupfer, lackisoliert

Spécifications pour types particuliers de fils de bobinage -- Partie 0-1: Exigences générales - Fil de section circulaire en cuivre émaillé

La présente partie de la CEI 60317 spécifie les exigences générales pour les fils de bobinage de section circulaire en cuivre émaillé avec ou sans couche adhérente. Les changements principaux par rapport à l'édition précédente sont:
- ajout, dans les Tableaux 1 et A.1, de l'accroissement minimal dû à l'isolant de Grade 3 et des diamètres extérieurs maximaux pour les fils de diamètre nominal du conducteur jusqu'à 0,071 mm;
- révisions apportées à l'accroissement minimal de la couche adhérente pour les fils de diamètre nominal du conducteur jusqu'à 0,100 mm, dans les Tableaux 2 et A.2;
- ajout des exigences de claquage du diélectrique de Grade 3 pour les fils de diamètre nominal du conducteur jusqu'à 0,071 mm; et
- nouvelle exigence de détection des microfissures en immersion pour les fils émaillés avec polyuréthanne de Grade 3.
Cette norme doit être lue conjointement avec la série CEI 60851. Les numéros d'articles dans la présente partie de la CEI 60317 sont identiques aux numéros d'essais respectifs de la CEI 60851.

Specifikacije za posebne tipe navitij - 0-1. del: Splošne zahteve - Emajliran okrogel bakren vodnik (IEC 60317-0-1:2008)

General Information

Status
Withdrawn
Publication Date
20-Jul-2008
Withdrawal Date
13-Nov-2016
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
14-Nov-2016
Due Date
07-Dec-2016
Completion Date
14-Nov-2016

Relations

Buy Standard

Standard
EN 60317-0-1:2008
English language
32 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60317-0-1:2008
01-september-2008
1DGRPHãþD
SIST EN 60317-0-1:2001
SIST EN 60317-0-1:2001/A1:2001
SIST EN 60317-0-1:2001/A2:2006
Specifikacije za posebne tipe navitij - 0-1. del: Splošne zahteve - Emajliran okrogel
bakren vodnik (IEC 60317-0-1:2008)
Specifications for particular types of winding wires - Part 0-1: General requirements -
Enamelled round copper wire
Technische Lieferbedingungen für bestimmte Typen von Wickeldrähten - Teil 0-1:
Allgemeine Anforderungen - Runddrähte aus Kupfer, lackisoliert
Spécifications pour types particuliers de fils de bobinage - Partie 0-1: Prescriptions
générales - Fil de section circulaire en cuivre émaillé
Ta slovenski standard je istoveten z: EN 60317-0-1:2008
ICS:
29.060.10 Žice Wires
SIST EN 60317-0-1:2008 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60317-0-1:2008

---------------------- Page: 2 ----------------------

SIST EN 60317-0-1:2008

EUROPEAN STANDARD
EN 60317-0-1

NORME EUROPÉENNE
June 2008
EUROPÄISCHE NORM

ICS 29.060.10 Supersedes EN 60317-0-1:1998 + A1:2000 + A2:2005


English version


Specifications for particular types of winding wires -
Part 0-1: General requirements -
Enamelled round copper wire
(IEC 60317-0-1:2008)


Spécifications pour types particuliers  Technische Lieferbedingungen
de fils de bobinage - für bestimmte Typen von Wickeldrähten -
Partie 0-1: Exigences générales - Teil 0-1: Allgemeine Anforderungen -
Fil de section circulaire en cuivre émaillé Runddrähte aus Kupfer, lackisoliert
(CEI 60317-0-1:2008) (IEC 60317-0-1:2008)




This European Standard was approved by CENELEC on 2008-05-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60317-0-1:2008 E

---------------------- Page: 3 ----------------------

SIST EN 60317-0-1:2008
EN 60317-0-1:2008 - 2 -
Foreword
The text of document 55/1033/CDV, future edition 3 of IEC 60317-0-1, prepared by IEC TC 55, Winding
wires, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 60317-0-1 on 2008-05-01.
This European Standard supersedes EN 60317-0-1:1998 + A1:2000 + A2:2005.
The main changes with respect to EN 60317-0-1:1998 are listed below:
– addition of Grade 3 minimum insulation increases and maximum overall diameters for wires up to
0,071 mm nominal conductor diameter in Tables 1 and A.1;
– revisions to minimum increase in bonding layer for wires up to 0,100 mm nominal conductor diameter
in Tables 2 and A.2;
– addition of Grade 3 dielectric breakdown requirements for wires up to 0,071 mm nominal conductor
diameter;
– new pin hole test requirement for Grade 3 polyurethane wires.
This standard is to be read in conjunction with the EN 60851 series. The clause numbers used in
EN 60317-0-1 are identical with the respective test numbers of EN 60851.
In case of inconsistencies between EN 60851 and EN 60317-0-1, the latter shall prevail.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-02-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2011-05-01
Annex ZA has been added by CENELEC.
__________

---------------------- Page: 4 ----------------------

SIST EN 60317-0-1:2008
- 3 - EN 60317-0-1:2008
Endorsement notice
The text of the International Standard IEC 60317-0-1:2008 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60317-2 NOTE  Harmonized as EN 60317-2:1994 (not modified).
IEC 60317-4 NOTE  Harmonized as EN 60317-4:1994 (not modified).
IEC 60317-11 NOTE  Harmonized as EN 60317-11:2000 (not modified).
IEC 60317-19 NOTE  Harmonized as EN 60317-19:1995 (not modified).
IEC 60317-20 NOTE  Harmonized as EN 60317-20:1995 (not modified).
IEC 60317-21 NOTE  Harmonized as EN 60317-21:1995 (not modified).
IEC 60317-23 NOTE  Harmonized as EN 60317-23:1995 (not modified).
IEC 60317-35 NOTE  Harmonized as EN 60317-35:1994 (not modified).
IEC 60317-36 NOTE  Harmonized as EN 60317-36:1994 (not modified).
IEC 60317-51 NOTE  Harmonized as EN 60317-51:2001 (not modified).
__________

---------------------- Page: 5 ----------------------

SIST EN 60317-0-1:2008
EN 60317-0-1:2008 - 4 -
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

1) 2)
IEC 60172 - Test procedure for the determination of the EN 60172 1994
temperature index of enamelled winding wires


IEC 60264 Series Packaging of winding wires EN 60264 Series


IEC 60317 Series Specifications for particular types of winding EN 60317 Series
wires


IEC 60851 Series Winding wires - Test methods EN 60851 Series


1)
ISO 3 - Preferred numbers - Series of preferred - -
numbers




1)
Undated reference.
2)
Valid edition at date of issue.

---------------------- Page: 6 ----------------------

SIST EN 60317-0-1:2008
IEC 60317-0-1
Edition 3.0 2008-03
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE


Specifications for particular types of winding wires –
Part 0-1: General requirements – Enamelled round copper wire

Spécifications pour types particuliers de fils de bobinage –
Partie 0-1: Exigences générales – Fil de section circulaire en cuivre émaillé

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
U
CODE PRIX
ICS 29.060.10 ISBN 2-8318-9636-3

---------------------- Page: 7 ----------------------

SIST EN 60317-0-1:2008
– 2 – 60317-0-1 © IEC:2008
CONTENTS
FOREWORD.4
INTRODUCTION.6

1 Scope.7
2 Normative references.7
3 Terms, definitions and general notes on methods of test and appearance.7
3.1 Terms and definitions .7
3.2 General notes on methods of test .9
3.3 Appearance .9
4 Dimensions.9
4.1 Conductor diameter .9
4.2 Out of roundness of conductor (nominal conductor diameters over 0,063 mm) .12
4.3 Minimum increase in diameter due to the insulation and the bonding layer
(nominal conductor diameters over 0,063 mm).12
4.3.1 Enamelled wires without a bonding layer .12
4.3.2 Enamelled wires with a bonding layer .12
4.4 Maximum overall diameter .12
4.4.1 Enamelled wires without a bonding layer .12
4.4.2 Enamelled wires with a bonding layer .12
5 Electrical resistance.12
6 Elongation .13
7 Springiness.13
7.1 Nominal conductor diameters from 0,080 mm up to and including 1,600 mm .13
7.2 Nominal conductor diameters over 1,600 mm.13
8 Flexibility and adherence .15
8.1 Mandrel winding test (nominal conductor diameters up to and including
1,600 mm) .15
8.2 Stretching test (nominal conductor diameters over 1,600 mm).15
8.3 Jerk test (nominal conductor diameters up to and including 1,000 mm) .15
8.4 Peel test (nominal conductor diameters over 1,000 mm) .15
9 Heat shock .15
9.1 Nominal conductor diameters up to and including 1,600 mm .15
9.2 Nominal conductor diameters over 1,600 mm.16
10 Cut-through .16
11 Resistance to abrasion .16
12 Resistance to solvents .16
13 Breakdown voltage .16
13.1 Nominal conductor diameters up to and including 0,100 mm .17
13.2 Nominal conductor diameters over 0,100 mm up to and including 2,500 mm.17
13.3 Nominal conductor diameters over 2,500 mm.18
14 Continuity of insulation (nominal conductor diameters up to and including
1,600 mm) .19
15 Temperature index.19
16 Resistance to refrigerants .19
17 Solderability.19

---------------------- Page: 8 ----------------------

SIST EN 60317-0-1:2008
60317-0-1 © IEC:2008 – 3 –
18 Heat or solvent bonding .19
19 Dielectric dissipation factor .19
20 Resistance to transformer oil .19
21 Loss of mass .19
23 Pin hole test .20
30 Packaging .20

Annex A (informative) Dimensions for intermediate nominal conductor diameters (R 40) .21
Annex B (informative) Method for the calculation of linear resistance .24
Annex C (informative) Resistance .26

Bibliography .28

Table 1 – Dimensions of enamelled wires (R 20) .10
Table 2 – Dimensions of enamelled wires with a bonding layer (R 20).11
Table 3 – Electrical resistances .12
Table 4 – Elongation .13
Table 5 – Springiness.14
Table 6 – Mandrel winding.15
Table 7 – Heat shock .16
Table 8 – Breakdown voltage .17
Table 9 – Breakdown voltage .18
Table 10 – Breakdown voltage.18
Table 11 – Continuity of insulation.19
Table 12 – Maximum number of pin holes.20
Table A.1 – Dimensions of enamelled wires (R 40) .21
Table A.2 – Dimensions of enamelled wires with a bonding layer (R 40).22
Table B.1 – Ratios .24
Table C.1 – Electrical resistances .26

---------------------- Page: 9 ----------------------

SIST EN 60317-0-1:2008
– 4 – 60317-0-1 © IEC:2008
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

SPECIFICATIONS FOR PARTICULAR TYPES
OF WINDING WIRES –

Part 0-1: General requirements –
Enamelled round copper wire


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60317-0-1 has been prepared by IEC technical committee 55:
Winding wires.
This third edition cancels and replaces the second edition published in 1997, its amendment 1
(1999), and its amendment 2 (2005) and constitutes a technical revision.
The main changes with respect to the previous edition are listed below:
– addition of Grade 3 minimum insulation increases and maximum overall diameters for wires
up to 0,071 mm nominal conductor diameter in Tables 1 and A.1;
– revisions to minimum increase in bonding layer for wires up to 0,100 mm nominal conductor
diameter in Tables 2 and A.2;
– addition of Grade 3 dielectric breakdown requirements for wires up to 0,071 mm nominal
conductor diameter;

---------------------- Page: 10 ----------------------

SIST EN 60317-0-1:2008
60317-0-1 © IEC:2008 – 5 –
– new pin hole test requirement for Grade 3 polyurethane wires.
This standard is to be read in conjunction with the IEC 60851 series. The clause numbers used
in this part of IEC 60317 are identical with the respective test numbers of IEC 60851.
In case of inconsistencies between IEC 60851 and this part of IEC 60317, the latter shall
prevail.
The text of this standard is based on the following documents:
CDV Report on Voting
55/1033/CDV 55/1053A/RVC

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 60317 series, under the general title Specifications for particular
types of winding wires, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.

---------------------- Page: 11 ----------------------

SIST EN 60317-0-1:2008
– 6 – 60317-0-1 © IEC:2008
INTRODUCTION
This part of IEC 60317 is one of a series which deals with insulated wires used for windings in
electrical equipment. The series has three groups describing:
1) winding wires – Test methods (IEC 60851);
2) specifications for particular types of winding wires (IEC 60317);
3) packaging of winding wires (IEC 60264).

---------------------- Page: 12 ----------------------

SIST EN 60317-0-1:2008
60317-0-1 © IEC:2008 – 7 –
SPECIFICATIONS FOR PARTICULAR TYPES
OF WINDING WIRES –

Part 0-1: General requirements –
Enamelled round copper wire



1 Scope
This part of IEC 60317 specifies general requirements of enamelled round copper winding
wires with or without bonding layer.
The range of nominal conductor diameters is given in the relevant specification sheet.
When reference is made to a winding wire according to a standard of the IEC 60317 series
mentioned under Clause 2, the following information is given in the description:
– reference to IEC specification;
– nominal conductor diameter in millimetres;
– grade.
EXAMPLE IEC 60317-1 – 0,500 Grade 2
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60172, Test procedure for the determination of the temperature index of enamelled winding
wires
IEC 60264 ( all parts), Packaging of winding wires
IEC 60317 (all parts), Specifications for particular types of winding wires
IEC 60851 (all parts), Winding wires – Test methods
ISO 3, Preferred numbers – Series of preferred numbers
3 Terms, definitions and general notes on methods of test and appearance
For the purposes of this document, the following terms and definitions apply.
3.1 Terms and definitions
3.1.1
bonding layer
material which is deposited on an enamelled wire and which has the specific function of
bonding wires together

---------------------- Page: 13 ----------------------

SIST EN 60317-0-1:2008
– 8 – 60317-0-1 © IEC:2008
3.1.2
class
thermal performance of a wire expressed by the temperature index and the heat shock
temperature
3.1.3
coating
material which is deposited on a conductor or wire by a suitable means and then dried and/or
cured
3.1.4
conductor
bare metal after removal of the insulation
3.1.5
crack
opening in the insulation which exposes the conductor to view at the stated magnification
3.1.6
dual coating
insulation composed of two different materials, an underlying and a superimposed coating
3.1.7
enamelled wire
wire coated with an insulation of cured resin
3.1.8
grade
range of thickness of the insulation of a wire
3.1.9
insulation
coating or covering on the conductor with the specific function of withstanding voltage
3.1.10
nominal conductor dimension
designation of the conductor size in accordance with IEC 60317
3.1.11
normal vision
20/20 vision, with corrective lenses, if necessary.
3.1.12
sole coating
insulation composed of one material
3.1.13
winding wire
wire used for winding a coil to provide a magnetic field
3.1.14
wire
conductor coated or covered with an insulation

---------------------- Page: 14 ----------------------

SIST EN 60317-0-1:2008
60317-0-1 © IEC:2008 – 9 –

3.2 General notes on methods of test
All methods of test to be used for this part of IEC 60317 are given in the IEC 60851 series.
Where no specific range of nominal conductor diameters is given for a test, the test applies to
all nominal conductor diameters covered by the specification sheet.
Unless otherwise specified, all tests shall be carried out at a temperature from 15 °C to 35 °C
and a relative humidity from 45 % to 75 %. Before measurements are made, the specimens
shall be preconditioned under these atmospheric conditions for a time sufficient to allow the
specimens to reach stability.
The wire to be tested shall be removed from the packaging in such a way that the wire will not
be subjected to tension or unnecessary bends. Before each test, sufficient wire should be
discarded to ensure that any damaged wire is not included in the test specimens.
3.3 Appearance
The film coating shall be essentially smooth and continuous, free from streaks, blisters and
foreign material when examined with normal vision, as wound on the original spool or reel.
When agreed upon between the user and supplier, examination using 6× to 10× magnification
shall be used for wires with a nominal diameter less than 0,1 mm.
4 Dimensions
4.1 Conductor diameter
The series of preferred nominal conductor diameters shall correspond to series R 20 according
to ISO 3. The actual values and their tolerances are given in Tables 1 and 2.
The series of intermediate diameters from which the user may select intermediate nominal
conductor diameters, when required for technical reasons, shall correspond to series R 40
according to ISO 3. The actual values and their tolerances are given in Annex A.
The conductor diameter shall not differ from the nominal diameter by more than the limit given
in Tables 1 or 2.
NOTE For wires up to and including 0,063 mm nominal conductor diameter, see Table 3.

---------------------- Page: 15 ----------------------

SIST EN 60317-0-1:2008
– 10 – 60317-0-1 © IEC:2008
Table 1 – Dimensions of enamelled wires (R 20)
Nominal Conductor Minimum increase Maximum overall
conductor tolerance due to the insulation diameter
diameter mm mm
±
mm mm Grade 1 Grade 2 Grade 3 Grade 1 Grade 2 Grade 3
0,006 0,026
0,018 0,002 0,004 0,022 0,024
0,007 0,030
0,020 0,002 0,004 0,024 0,027
0,008 0,033
0,022 0,002 0,005 0,027 0,030
0,008 0,037
0,025 0,003 0,005 0,031 0,034
0,009 0,042
0,028 0,003 0,006 0,034 0,038
0,032 0,003 0,007 0,010 0,039 0,043 0,047
0,036 0,004 0,008 0,011 0,044 0,049 0,053
0,040 0,004 0,008 0,012 0,049 0,054 0,058
0,045 0,005 0,009 0,013 0,055 0,061 0,066
0,050 0,005 0,010 0,014 0,060 0,066 0,072

0,056 0,006 0,011 0,015 0,067 0,074 0.081
0,063 0,006 0,012 0,017 0,076 0,083 0,090
0,071 0,003 0,007 0,012 0,018 0,084 0,091 0,098
0,080 0,003 0,007 0,014 0,020 0,094 0,101 0,108
0,090 0,003 0,008 0,015 0,022 0,105 0,113 0,120
0,100 0,003 0,008 0,016 0,023 0,117 0,125 0,132
0,112 0,003 0,009 0,017 0,026 0,130 0,139 0,147
0,125 0,003 0,010 0,019 0,028 0,144 0,154 0,163
0,140 0,003 0,011 0,021 0,030 0,160 0,171 0,181
0,160 0,003 0,012 0,023 0,033 0,182 0,194 0,205
0,180 0,003 0,013 0,025 0,036 0,204 0,217 0,229
0,200 0,003 0,014 0,027 0,039 0,226 0,239 0,252
0,224 0,003 0,015 0,029 0,043 0,252 0,266 0,280
0,250 0,004 0,017 0,032 0,048 0,281 0,297 0,312
0,280 0,004 0,018 0,033 0,050 0,312 0,329 0,345
0,315 0,004 0,019 0,035 0,053 0,349 0,367 0,384
0,355 0,004 0,020 0,038 0,057 0,392 0,411 0,428
0,400 0,005 0,021 0,040 0,060 0,439 0,459 0,478
0,450 0,005 0,022 0,042 0,064 0,491 0,513 0,533
0,500 0,005 0,024 0,045 0,067 0,544 0,566 0,587
0,560 0,006 0,025 0,047 0,071 0,606 0,630 0,653
0,630 0,006 0,027 0,050 0,075 0,679 0,704 0,728
0,710 0,007 0,028 0,053 0,080 0,762 0,789 0,814
0,800 0,008 0,030 0,056 0,085 0,855 0,884 0,911
0,900 0,009 0,032 0,060 0,090 0,959 0,989 1,018
1,000 0,010 0,034 0,063 0,095 1,062 1,094 1,124
1,120 0,011 0,034 0,065 0,098 1,184 1,217 1,248
1,250 0,013 0,035 0,067 0,100 1,316 1,349 1,381
1,400 0,014 0,036 0,069 0,103 1,468 1,502 1,535
1,600 0,016 0,038 0,071 0,107 1,670 1,706 1,740

1,800 0,018 0,039 0,073 0,110 1,872 1,909 1,944
2,000 0,020 0,040 0,075 0,113 2,074 2,112 2,148
2,240 0,022 0,041 0,077 0,116 2,316 2,355 2,392
2,500 0,025 0,042 0,079 0,119 2,578 2,618 2,656
2,800 0,028 0,043 0,081 0,123 2,880 2,922 2,961
3,150 0,032 0,045 0,084 0,127 3,233 3,276 3,316
3,550 0,036 0,046 0,086 0,130 3,635 3,679 3,721
4,000 0,040 0,047 0,089 0,134 4,088 4,133 4,176
4,500 0,045 0,049 0,092 0,138 4,591 4,637 4,681
5,000 0,050 0,050 0,094 0,142 5,093 5,141 5,186
For intermediate nominal conductor diameters, the minimum increase figure corresponding to the next larger
nominal conductor diameter shall be taken.
NOTE 1 Minimum overall diameter up to and inclusive of 0,060 mm is
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.