Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes) (IEC 61347-2-10:2000/A1:2008)

Geräte für Lampen - Teil 2-10: Besondere Anforderungen an elektronische Wechselrichter und Konverter für Hochfrequenzbetrieb von röhrenförmigen Kaltstart-Entladungslampen (Neonröhren) (IEC 61347-2-10:2000/A1:2008)

Appareillages de lampes - Partie 2-10: Prescriptions particulières pour onduleurs et convertisseurs électroniques destinés à l'alimentation en haute fréquence des lampes tubulaires à décharge à démarrage à froid (tubes néon) (CEI 61347-2-10:2000/A1:2008)

Stikalne naprave za sijalke - 2 -10. del: Posebne zahteve za elektronske razsmernike in presmernike za visokofrekvenčno obratovanje cevastih sijalk z hladnim vžigom (neonske cevi) (IEC 61347-2-10:2000/A1:2008)

General Information

Status
Published
Publication Date
22-Feb-2009
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
09-Feb-2009
Due Date
16-Apr-2009
Completion Date
23-Feb-2009

Relations

Effective Date
01-Feb-2025
Effective Date
01-Apr-2009

Overview

SIST EN 61347-2-10:2002/A1:2009 is a European standard that specifies the particular requirements for electronic inverters and converters designed for the high-frequency operation of cold start tubular discharge lamps, commonly known as neon tubes. This standard, prepared by the European Committee for Electrotechnical Standardization (CENELEC), aligns with the International Electrotechnical Commission (IEC) standard IEC 61347-2-10:2000/A1:2008, ensuring harmonized specifications for lamp controlgear within Europe.

Catering specifically to controlgear used for neon lighting systems, this standard addresses the unique electrical and safety characteristics of cold start tubular discharge lamps operated at high frequencies. The amendment A1 introduced in 2009 updates existing definitions, performance parameters, and safety requirements to reflect technological advancements and practical usage in lighting applications.

Key Topics

  • Lamp Controlgear Specifics
    Focused on electronic inverters and converters that power cold start tubular discharge lamps (neon tubes) at high frequencies, ensuring efficient and safe lamp operation.

  • No-Load Rated Output Voltage
    Defines the maximum rated voltage present at the output terminals without load. This is critical for designing safe circuits and protecting components.

  • Output High-Voltage Circuit
    Clarifies terminology referring to circuits supplying high voltage to neon lamps, emphasizing safety and testing practices.

  • Marking Requirements
    Specifies the labeling and documentation that must accompany lamp controlgear to guarantee clarity in installation, maintenance, and compliance.

  • Electric Strength Testing
    Sets standards for insulation testing, ensuring durability and safety of electronic controlgear under high voltage stresses.

  • Open-Circuit Protective Devices
    Details protective mechanisms designed to prevent damage or hazards when the output circuit of the inverter or converter is open.

  • Measurement Techniques
    Provides guidance on precise measurement of current and voltage in the output circuits, critical for performance evaluation and compliance testing.

Applications

The EN 61347-2-10 standard is essential in various applications involving neon lighting, including:

  • Commercial and Retail Lighting
    Neon signage and decorative lighting installations utilizing high-frequency electronic invertors enhance durability and aesthetic qualities.

  • Architectural Illumination
    For outdoor and indoor lighting where cold start discharge lamps provide visual effects, ensuring safe, reliable operation.

  • Industrial Lighting Systems
    Facilities employing neon tubes for specialized lighting solutions benefit from standardized controlgear ensuring energy efficiency and safety.

  • Public Infrastructure
    Neon lighting in transit stations, emergency exits, and public art installations equipped with certified controlgear complying with EN 61347-2-10.

Implementing this standard helps manufacturers and system integrators achieve optimal lamp life, reduce electromagnetic interference, and ensure user safety.

Related Standards

  • EN 61347-1 – General and safety requirements for lamp controlgear, providing foundational stipulations adopted and amended in the EN 61347 series.

  • IEC 61347-2-10:2000/A1:2008 – The international counterpart to this European standard, setting global benchmarks for electronic inverters and converters for neon tubes.

  • EN 61347-2-x Series – Covers various specific lamp controlgear requirements, including different lamp types and operational conditions.

  • Standards on Electrical Safety and EMC – Complementary standards such as those governing electromagnetic compatibility and device insulation, which support compliance in high-frequency lamp controlgear.


By adhering to SIST EN 61347-2-10:2002/A1:2009, manufacturers and lighting professionals ensure the production and use of reliable, safe, and efficient electronic controlgear tailored for neon tube applications. This complies with European and international regulations, promoting quality and interoperability in the lighting industry.

Amendment

SIST EN 61347-2-10:2002/A1:2009

English language
6 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 61347-2-10:2002/A1:2009 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes) (IEC 61347-2-10:2000/A1:2008)". This standard covers: Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes) (IEC 61347-2-10:2000/A1:2008)

Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes) (IEC 61347-2-10:2000/A1:2008)

SIST EN 61347-2-10:2002/A1:2009 is classified under the following ICS (International Classification for Standards) categories: 29.130.01 - Switchgear and controlgear in general; 29.140.99 - Other standards related to lamps. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 61347-2-10:2002/A1:2009 has the following relationships with other standards: It is inter standard links to SIST EN IEC 61347-2-10:2025, SIST EN 61347-2-10:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 61347-2-10:2002/A1:2009 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase SIST EN 61347-2-10:2002/A1:2009 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2009
6WLNDOQHQDSUDYH]DVLMDONHGHO3RVHEQH]DKWHYH]DHOHNWURQVNH
UD]VPHUQLNHLQSUHVPHUQLNH]DYLVRNRIUHNYHQþQRREUDWRYDQMHFHYDVWLKVLMDON]
KODGQLPYåLJRP QHRQVNHFHYL  ,(&$
Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and
convertors for high-frequency operation of cold start tubular discharge lamps (neon
tubes) (IEC 61347-2-10:2000/A1:2008)
Geräte für Lampen - Teil 2-10: Besondere Anforderungen an elektronische
Wechselrichter und Konverter für Hochfrequenzbetrieb von röhrenförmigen Kaltstart-
Entladungslampen (Neonröhren) (IEC 61347-2-10:2000/A1:2008)
Appareillages de lampes - Partie 2-10: Prescriptions particulières pour onduleurs et
convertisseurs électroniques destinés à l'alimentation en haute fréquence des lampes
tubulaires à décharge à démarrage à froid (tubes néon) (CEI 61347-2-10:2000/A1:2008)
Ta slovenski standard je istoveten z: EN 61347-2-10:2001/A1:2009
ICS:
29.130.01 Stikalne in krmilne naprave Switchgear and controlgear
na splošno in general
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 61347-2-10/A1
NORME EUROPÉENNE
January 2009
EUROPÄISCHE NORM
ICS 29.140.99
English version
Lamp controlgear -
Part 2-10: Particular requirements for electronic invertors and convertors
for high-frequency operation of cold start tubular discharge lamps
(neon tubes)
(IEC 61347-2-10:2000/A1:2008)
Appareillages de lampes -  Geräte für Lampen -
Partie 2-10: Prescriptions particulières Teil 2-10: Besondere Anforderungen
pour onduleurs et convertisseurs an elektronische Wechselrichter
électroniques destinés à l'alimentation und Konverter für Hochfrequenzbetrieb
en haute fréquence des lampes tubulaires von röhrenförmigen
à décharge à démarrage à froid Kaltstart-Entladungslampen (Neonröhren)
(tubes néon) (IEC 61347-2-10:2000/A1:2008)
(CEI 61347-2-10:2000/A1:2008)
This amendment A1 modifies the European Standard EN 61347-2-10:2001; it was approved by CENELEC on
2008-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: avenue Marnix 17, B - 1000 Brussels

© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61347-2-10:2001/A1:2009 E

Foreword
The text of document 34C/849/FDIS, future amendment 1 to IEC 61347-2-10:2000, prepared by SC 34C,
Auxiliaries for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC
parallel vote and was approved by CENELEC as amendment A1 to EN 61347-2-10:2001 on 2008-12-01.
The following dates were fixed:
– latest date by which the amendment has to be
implemented at national level by publication of
an identical national standard or by endorsement (dop) 2009-09-01
– latest date by which the national standards conflicting
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.