Laboratory glassware -- Narrow-necked boiling flasks

Verrerie de laboratoire -- Fioles coniques et ballons à col étroit

Laboratorijska steklovina - Vrelne bučke (z ozkim vratom)

General Information

Status
Published
Publication Date
31-Mar-1998
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Apr-1998
Due Date
01-Apr-1998
Completion Date
01-Apr-1998

Relations

Effective Date
01-Apr-1998

Overview

SIST ISO 1773:1998 specifies international requirements for laboratory glassware, focusing specifically on narrow-necked boiling flasks, including conical flasks and round- or flat-bottomed boiling flasks. Developed by ISO Technical Committee ISO/TC 48 (Laboratory glassware and related apparatus), Subcommittee SC 2 (Non-volumetric laboratory glassware), this standard ensures uniformity in dimensions, materials, and construction for glassware widely used in laboratory testing and manufacturing.

This second edition revises the original 1976 standard by updating the dimensions, tolerances, materials, and testing methods, aligning them with ISO 3585 standards for borosilicate glass 3.3. The standard facilitates compatibility and safety in laboratory environments.

Key Topics

  • Scope and Application
    SIST ISO 1773:1998 applies to a series of conical flasks and boiling flasks with narrow necks intended for direct laboratory use or as components in other laboratory equipment manufacturing.

  • Material Requirements
    All flasks covered by this standard must be made of borosilicate glass 3.3 as per ISO 3585. This glass type offers high chemical durability and thermal resistance, essential for boiling and heating applications.

  • Dimensions and Design Specifications

    • Conical flasks: Capacities range from 25 mL up to 5000 mL, with specified diameters, neck lengths (1 to 1.25 times the neck diameter), wall thickness, and base curvature to ensure stability and functional reliability.
    • Boiling flasks (round and flat bottom): Capacities vary from 50 mL to 10,000 mL, with defined base diameters approximately 50% of maximum body diameter for stability.
    • Wall thickness minimum values are outlined to balance durability and safety.
    • The neck must maintain a near-circular cross-section and reinforced at the opening to withstand lab conditions.
  • Construction Criteria
    Flasks must stand vertically without tilting or rocking when placed on horizontal surfaces, ensuring practical laboratory safety and ease of handling.

  • Marking and Traceability
    Each flask must bear clear, permanent markings for:

    • Nominal capacity (e.g., "100 ml")
    • Manufacturer’s name or trademark
    • A surface suitable for additional markings with pencil or similar tools
      Inclusion of reference to SIST ISO 1773:1998 on the flask is recommended for clarity.

Applications

SIST ISO 1773:1998 narrow-necked boiling flasks are fundamental tools in:

  • Chemical laboratories for refluxing, boiling, mixing, and heating solutions with precise volume control.
  • Educational institutions for chemistry training and experiments requiring standard, reliable laboratory glassware.
  • Pharmaceutical and biotechnological processes where controlled heating and chemical reactions must be conducted safely.
  • Industrial manufacturing settings for quality control and product development requiring standardized glassware for processing and testing.

Adherence to ISO 1773 guarantees compatibility with existing laboratory apparatus and contributes to reproducible experimental conditions, helping laboratories worldwide maintain best practices.

Related Standards

For comprehensive laboratory glassware quality and compatibility, SIST ISO 1773:1998 references and aligns with these standards:

  • ISO 3585:1991 – Borosilicate glass 3.3 - Properties and testing (material specification)
  • ISO 383:1976 – Laboratory glassware - Interchangeable conical ground joints
  • ISO 4797:1981 – Laboratory glassware - Conical flasks and flasks with conical ground joints
  • ISO 3819:1985 – Laboratory glassware - Beakers, test tubes, and culture tubes
  • ISO 4785:1997 – Laboratory glassware - Straight bore glass taps for general use

These related standards ensure a harmonized approach covering materials, joints, volumetric and non-volumetric laboratory glassware, enhancing interoperability and performance safety among various pieces of equipment.


Keywords: ISO 1773, laboratory glassware, narrow-necked boiling flasks, conical flasks, borosilicate glass, glassware dimensions, laboratory safety, boiling flask dimensions, ISO standards laboratory, glass flask specification.

Standard

ISO 1773:1997 - Laboratory glassware -- Narrow-necked boiling flasks

English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 1773:1997 - Verrerie de laboratoire -- Fioles coniques et ballons a col étroit

French language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 1773:1997 - Verrerie de laboratoire -- Fioles coniques et ballons a col étroit

French language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

SIST ISO 1773:1998 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Laboratory glassware -- Narrow-necked boiling flasks". This standard covers: Laboratory glassware -- Narrow-necked boiling flasks

Laboratory glassware -- Narrow-necked boiling flasks

SIST ISO 1773:1998 is classified under the following ICS (International Classification for Standards) categories: 71.040.20 - Laboratory ware and related apparatus. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST ISO 1773:1998 has the following relationships with other standards: It is inter standard links to SIST ISO 1773:1995. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase SIST ISO 1773:1998 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-1998
1DGRPHãþD
SIST ISO 1773:1995
/DERUDWRULMVNDVWHNORYLQD9UHOQHEXþNH ]R]NLPYUDWRP
Laboratory glassware -- Narrow-necked boiling flasks
Verrerie de laboratoire -- Fioles coniques et ballons à col étroit
Ta slovenski standard je istoveten z: ISO 1773:1997
ICS:
71.040.20 Laboratorijska posoda in Laboratory ware and related
aparati apparatus
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

IS0 1773:1997(E)
Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of national standards bodies
(IS0 member bodies). The work of preparing International Standards is normally carried out through IS0
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
in liaison with ISO, also take part in the work. IS0 collaborates closely with the
non-governmental,
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to the member bodies for
voting. Publication as an International Standard requires approvall by at least 75 % of the member bodies
casting a vote.
This International Standard IS0 1773 has been prepared by Technical Committee lSO/TC 48, Laboratory
glassware and related apparatus, Subcommittee SC 2, General laboratory glassware (other than measuring
apparatus).
This second edition cancels and replaces the first edition (IS0 1773:1976) which has been technically revised
and includes the following changes:
- dimensions and tolerances have been brought up to date;
- material and tests have been modified in accordance with IS0 3585.
Annex A of this International Standard is for information only.
0 is0 1997
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from the publisher.
International Organization for Standardization
Case postale 56 l CH-1211 Geneve 20 l Switzerland
central @ iso.ch
Internet
x.400 c=ch; a=400net; p=iso; o=isocs; s=central
Printed in Switzerland
ii
IS0 1773:1997(E)
INTERNATIONAL STANDARD @ IS0
Laboratory glassware - Narrow-necked boiling flasks
Scope
This International Standard specifies requirements and dimensions for an internationally acceptable series of
conical flasks and of flat-bottom and round-bottom flasks for general laboratory purposes. The flasks are
provided for
- direct use in a laboratory, fitting together with other equipment for general laboratory purposes;
- further work up to other products.
NOTE - Annex A lists additional International Standards for other general-purpose laboratory glassware.
2 Normative reference
The following standard contains provisions which, through reference in this text, constitute provisions of this
International Standard. At the time of publication, the edition indicated was valid. All standards are subject to
revision, and parties to agreements based on this International Standard are encouraged to investigate the
possibility of applying the most recent edition of the standard indicated below. Members of IEC and IS0
maintain registers of currently valid International Standards.
IS 0 3585: 199 1, Borosilica te glass 3.3 - Properties.
3 Conical flasks
3.1 Series of nominal capacity
The series of nominal capacities of conical flasks is as follows (given in millilitres):
25-50-100-250-500-1000-2000-3000-5000
3.2 Nominal capacity
The nominal capacity of a flask is the value, selected from the series given in 3.1, which is closest to but not
larger than the actual volume to the base of neck.
NOTE - The body dimensions recommended in table 1 take this requirement into account, and as far as possible are in
accordance with the current production of flasks.
3.3 Material
Flasks shall be made from borosilicate glass 3.3 in accordance with IS0 3585, and shall be free from visible
defects and free from internal stress which would impair the performance of the flask.

@ IS0
3.4 Construction
3.4.1 Stability
The flasks shall stand vertically without rocking or spinning when placed on a level surface.
3.4.2 Neck
The neck of the flask shall be su
...


IS0 1773:1997(E)
Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of national standards bodies
(IS0 member bodies). The work of preparing International Standards is normally carried out through IS0
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
in liaison with ISO, also take part in the work. IS0 collaborates closely with the
non-governmental,
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to the member bodies for
voting. Publication as an International Standard requires approvall by at least 75 % of the member bodies
casting a vote.
This International Standard IS0 1773 has been prepared by Technical Committee lSO/TC 48, Laboratory
glassware and related apparatus, Subcommittee SC 2, General laboratory glassware (other than measuring
apparatus).
This second edition cancels and replaces the first edition (IS0 1773:1976) which has been technically revised
and includes the following changes:
- dimensions and tolerances have been brought up to date;
- material and tests have been modified in accordance with IS0 3585.
Annex A of this International Standard is for information only.
0 is0 1997
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from the publisher.
International Organization for Standardization
Case postale 56 l CH-1211 Geneve 20 l Switzerland
central @ iso.ch
Internet
x.400 c=ch; a=400net; p=iso; o=isocs; s=central
Printed in Switzerland
ii
IS0 1773:1997(E)
INTERNATIONAL STANDARD @ IS0
Laboratory glassware - Narrow-necked boiling flasks
Scope
This International Standard specifies requirements and dimensions for an internationally acceptable series of
conical flasks and of flat-bottom and round-bottom flasks for general laboratory purposes. The flasks are
provided for
- direct use in a laboratory, fitting together with other equipment for general laboratory purposes;
- further work up to other products.
NOTE - Annex A lists additional International Standards for other general-purpose laboratory glassware.
2 Normative reference
The following standard contains provisions which, through reference in this text, constitute provisions of this
International Standard. At the time of publication, the edition indicated was valid. All standards are subject to
revision, and parties to agreements based on this International Standard are encouraged to investigate the
possibility of applying the most recent edition of the standard indicated below. Members of IEC and IS0
maintain registers of currently valid International Standards.
IS 0 3585: 199 1, Borosilica te glass 3.3 - Properties.
3 Conical flasks
3.1 Series of nominal capacity
The series of nominal capacities of conical flasks is as follows (given in millilitres):
25-50-100-250-500-1000-2000-3000-5000
3.2 Nominal capacity
The nominal capacity of a flask is the value, selected from the series given in 3.1, which is closest to but not
larger than the actual volume to the base of neck.
NOTE - The body dimensions recommended in table 1 take this requirement into account, and as far as possible are in
accordance with the current production of flasks.
3.3 Material
Flasks shall be made from borosilicate glass 3.3 in accordance with IS0 3585, and shall be free from visible
defects and free from internal stress which would impair the performance of the flask.

@ IS0
3.4 Construction
3.4.1 Stability
The flasks shall stand vertically without rocking or spinning when placed on a level surface.
3.4.2 Neck
The neck of the flask shall be substantially circular in cross-section and the mouth of the neck shall not be
belled to any considerable distance from the top. The top of the neck shall be suitably strengthened.
3.5 Dimensions
3.5.1 Recommended dimensions
Dimensions for conical flasks are given in table 1.
Table 1 - Dimensions of conical flasks
Dimensions in millimetres
External External Overall Minimum
Nominal
diameter of diameter height wall
volume
body at of neck thickness
ml
widest point
25 42+1 2
...


NORME ISO
INTERNATIONALE
Deuxième édition
1997-04-01
Verrerie de laboratoire - Fioles coniques et
ballons à col étroit
Laboratory glassware - Narrow-necked boiling flasks
Numéro de référence
ISO 1773: 1997(F)
ISO 1773: 1997(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes nationaux de
normalisation (comités membres de I’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de I’ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec I’ISO participent également aux travaux. L’ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour
vote. Leur publication comme Normes internationales requiert l’approbation de 75 % au moins des comités
membres votants.
La Norme internationale ISO 1773 a été élaborée par le comité technique ISO/TC 48, Verrerie de laboratoire et
appareils connexes, sous-comité SC 2, Verrerie de laboratoire non jaugée.
Cette deuxième édition annule et remplace la première édition (ISO 1773:1976), dont elle constitue une révision
technique avec les modifications suivantes:
- les dimensions et tolérances ont été mises à jour;
- le matériau et les essais ont été modifiés conformément à I’ISO 3585.
L’annexe A de la présente Norme internationale est donnée uniquement à titre d’information.
0 ISO 1997
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun
procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l’accord
écrit de l’éditeur.
Organisation internationale de normalisation
Case postale 56 l CH-121 1 Genève 20 l Suisse
Internet central @ iso.ch
c=ch; a=400net; p=iso; o=isocs; s=central
x.400
Imprimé en Suisse
ii
ISO 1773: 1997(F)
NORME INTERNATIONALE o ISO
Verrerie de laboratoire - Fioles coniques et ballons à col étroit
1 Domaine d’application
La présente Norme internationale prescrit les exigences et les dimensions d’une série de fioles coniques et d’une série
de ballons à fond rond et de ballons à fond plat, qui sont internationalement acceptables pour les essais courants de
laboratoire. Les fioles et les ballons sont destinés à
- un usage direct en laboratoire, une adaptation à d’autre matériel de laboratoire à usage général;
- la fabrication d’autres produits.
NOTE - L’annexe A énumère d’autres Normes internationales pour verrerie de laboratoire à usage général.
2 Référence normative
La norme suivante contient des dispositions qui, par suite de la référence qui en est faite, constituent des
dispositions valables pour la présente Norme internationale. Au moment de la publication, l’édition indiquée était en
vigueur. Toute norme est sujette à révision et les parties prenantes des accords fondés sur la présente Norme
internationale sont invitées à rechercher la possibilité d’appliquer l’édition la plus récente de la norme indiquée ci-
après. Les membres de la CEI et de I’ISO possèdent le registre des Normes internationales en vigueur à un
moment donné.
ISO 3585: 1991, Verre borosilica té 3.3 - Propriétés.
3 Fioles coniques
3.1 Série des capacités nominales
La série des capacités nominales des fioles coniques est la suivante (donnée en millilitres):
25-50-100-250-500-1 000-2000-3000-5000
3.2 Capacité nominale
La capacité nominale d’une fiole conique est la valeur, choisie dans la série mentionnée en 3.1, qui est la plus proche
mais non supérieure au volume réel à la base du col.
NOTE - Les dimensions du corps recommandées dans le tableau 1 tiennent compte de cette exigence et sont en accord,
autant que possible, avec la fabrication courante des fioles coniques.
3.3 Matériau
Les fioles coniques doivent être fabriquées en verre borosilicaté 3.3 conforme à I’ISO 3585 et doivent être exemptes de
défauts visibles et exemptes de tensions internes qui pourraient détériorer les performances de la fiole conique.

0 os0
ISO 1773: 1997(F)
3.4 Construction
3.4.1 Stabilité
Les fioles coniques doivent pouvoir tenir verticalement sans osciller ni pivoter lorsqu’elles sont placées sur une surface
horizontale.
3.4.2 Col
Le col des fioles coniques doit être pratiquement circulaire dans une section droite et son ouverture ne doit pas être
évasée sur une distance trop grande à partir du sommet. Le sommet du col doit être convenablement renforcé.
3.5 Dimensions
3.5.1 Dimensions recommandées
Les dimensions pour les fioles coniques sont indiquées dans le tableau 1.
coniques
Tableau 1 - Dimensions des fioles
Dimensions en millimètres
50 08 9
51+1 22 rt 1 90 If: 3
100 098
64 k 1,5 22 I!I 1 105$r:3
II
85rt2 34 IL 1,5 145+
...


NORME ISO
INTERNATIONALE
Deuxième édition
1997-04-01
Verrerie de laboratoire - Fioles coniques et
ballons à col étroit
Laboratory glassware - Narrow-necked boiling flasks
Numéro de référence
ISO 1773: 1997(F)
ISO 1773: 1997(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes nationaux de
normalisation (comités membres de I’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de I’ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec I’ISO participent également aux travaux. L’ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour
vote. Leur publication comme Normes internationales requiert l’approbation de 75 % au moins des comités
membres votants.
La Norme internationale ISO 1773 a été élaborée par le comité technique ISO/TC 48, Verrerie de laboratoire et
appareils connexes, sous-comité SC 2, Verrerie de laboratoire non jaugée.
Cette deuxième édition annule et remplace la première édition (ISO 1773:1976), dont elle constitue une révision
technique avec les modifications suivantes:
- les dimensions et tolérances ont été mises à jour;
- le matériau et les essais ont été modifiés conformément à I’ISO 3585.
L’annexe A de la présente Norme internationale est donnée uniquement à titre d’information.
0 ISO 1997
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun
procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l’accord
écrit de l’éditeur.
Organisation internationale de normalisation
Case postale 56 l CH-121 1 Genève 20 l Suisse
Internet central @ iso.ch
c=ch; a=400net; p=iso; o=isocs; s=central
x.400
Imprimé en Suisse
ii
ISO 1773: 1997(F)
NORME INTERNATIONALE o ISO
Verrerie de laboratoire - Fioles coniques et ballons à col étroit
1 Domaine d’application
La présente Norme internationale prescrit les exigences et les dimensions d’une série de fioles coniques et d’une série
de ballons à fond rond et de ballons à fond plat, qui sont internationalement acceptables pour les essais courants de
laboratoire. Les fioles et les ballons sont destinés à
- un usage direct en laboratoire, une adaptation à d’autre matériel de laboratoire à usage général;
- la fabrication d’autres produits.
NOTE - L’annexe A énumère d’autres Normes internationales pour verrerie de laboratoire à usage général.
2 Référence normative
La norme suivante contient des dispositions qui, par suite de la référence qui en est faite, constituent des
dispositions valables pour la présente Norme internationale. Au moment de la publication, l’édition indiquée était en
vigueur. Toute norme est sujette à révision et les parties prenantes des accords fondés sur la présente Norme
internationale sont invitées à rechercher la possibilité d’appliquer l’édition la plus récente de la norme indiquée ci-
après. Les membres de la CEI et de I’ISO possèdent le registre des Normes internationales en vigueur à un
moment donné.
ISO 3585: 1991, Verre borosilica té 3.3 - Propriétés.
3 Fioles coniques
3.1 Série des capacités nominales
La série des capacités nominales des fioles coniques est la suivante (donnée en millilitres):
25-50-100-250-500-1 000-2000-3000-5000
3.2 Capacité nominale
La capacité nominale d’une fiole conique est la valeur, choisie dans la série mentionnée en 3.1, qui est la plus proche
mais non supérieure au volume réel à la base du col.
NOTE - Les dimensions du corps recommandées dans le tableau 1 tiennent compte de cette exigence et sont en accord,
autant que possible, avec la fabrication courante des fioles coniques.
3.3 Matériau
Les fioles coniques doivent être fabriquées en verre borosilicaté 3.3 conforme à I’ISO 3585 et doivent être exemptes de
défauts visibles et exemptes de tensions internes qui pourraient détériorer les performances de la fiole conique.

0 os0
ISO 1773: 1997(F)
3.4 Construction
3.4.1 Stabilité
Les fioles coniques doivent pouvoir tenir verticalement sans osciller ni pivoter lorsqu’elles sont placées sur une surface
horizontale.
3.4.2 Col
Le col des fioles coniques doit être pratiquement circulaire dans une section droite et son ouverture ne doit pas être
évasée sur une distance trop grande à partir du sommet. Le sommet du col doit être convenablement renforcé.
3.5 Dimensions
3.5.1 Dimensions recommandées
Les dimensions pour les fioles coniques sont indiquées dans le tableau 1.
coniques
Tableau 1 - Dimensions des fioles
Dimensions en millimètres
50 08 9
51+1 22 rt 1 90 If: 3
100 098
64 k 1,5 22 I!I 1 105$r:3
II
85rt2 34 IL 1,5 145+
...