This part of EN 13263 specifies the scheme for the evaluation of conformity of silica fume to EN 13263 1, including certification of conformity by a certification body.
This European Standard provides technical rules for production control by the manufacturer, including autocontrol testing of samples, and for the tasks of the certification body. It also provides rules for actions to be followed in the event of non-conformity and the procedure for the certification of conformity.
Silikastaub für Beton - Teil 2: Konformitätsbewertung
Dieser Teil der EN 13263 legt das Verfahren für die Konformitätsbewertung von Silikastaub nach EN 13263 1 fest einschließlich der Zertifizierung der Konformität durch eine Zertifizierungsstelle.
Diese Europäische Norm enthält technische Regeln für die Produktionskontrolle durch den Hersteller, einschließlich der internen Überwachungsprüfungen von Proben, und für die Aufgaben der Zertifizierungsstelle. Es enthält darüber hinaus Regeln für Maßnahmen, die bei Nichtkonformität zu ergreifen sind, sowie das Verfahren für die Zertifizierung der Konformität.
Fumée de silice pour béton - Partie 2: Evaluation de la conformité
Cette partie de l?EN 13263 spécifie le systeme d?évaluation de la conformité de la fumée de silice dans
l?EN 13263-1, comprenant la certification de conformité par un organisme de certification.
Cette Norme européenne présente des regles techniques relatives au contrôle de production effectué par le
fabricant (essai d?auto-contrôle des échantillons inclus) et aux tâches de l?organisme de certification. Le document
présente également des regles relatives aux actions a suivre en cas de non-conformité et les modes opératoires de
certification de conformité.
Mikro silika za beton – 2. del: Ovrednotenje skladnosti
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 13263-2:2005
01-september-2005
Mikro silika za beton – 2. del: Ovrednotenje skladnosti
Silica fume for concrete - Part 2: Conformity evaluation
Silikastaub für Beton - Teil 2: Konformitätsbewertung
Fumée de silice pour béton - Partie 2: Evaluation de la conformité
Ta slovenski standard je istoveten z: EN 13263-2:2005
ICS:
91.100.30 Beton in betonski izdelki Concrete and concrete
products
SIST EN 13263-2:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 13263-2:2005
---------------------- Page: 2 ----------------------
SIST EN 13263-2:2005
EUROPEAN STANDARD
EN 13263-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2005
ICS 91.100.30
English version
Silica fume for concrete - Part 2: Conformity evaluation
Fumée de silice pour béton - Partie 2: Evaluation de la Silikastaub für Beton - Teil 2: Konformitätsbewertung
conformité
This European Standard was approved by CEN on 19 May 2005.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2005 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13263-2:2005: E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
Contents
Page
Foreword .3
1 Scope .4
2 Normative references .4
3 Terms and definitions.4
4 Tasks for the manufacturer.8
4.1 Factory production control .8
4.2 Internal quality control .9
4.3 Autocontrol testing of samples .11
4.4 Further testing of samples .11
5 Tasks for the certification body .12
5.1 General .12
5.2 Surveillance, assessment and acceptance of the factory production control.12
5.3 Evaluation of the results of autocontrol testing of samples.12
5.4 Audit testing of samples taken at the production plant/depot and initial type testing.13
5.5 Initial inspection of the production facilities and the factory production control.14
5.6 Evaluation of test results during the initial period .15
6 Actions in the event of non-conformity.15
6.1 Actions to be taken by the manufacturer.15
6.2 Actions to be taken by the certification body.15
7 Procedure for third party certification of conformity .16
8 Certificate of conformity and conformity mark.16
8.1 Indication of conformity .16
8.2 Certificate of conformity.17
8.3 Conformity mark .17
Bibliography.19
2
---------------------- Page: 4 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
Foreword
This document (EN 13263-2:2005) has been prepared by Technical Committee CEN/TC 104 “Concrete and related
products”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by December 2005, and conflicting national standards shall be withdrawn at the latest
by December 2005.
EN 13263 has been prepared under a mandate given to CEN by the European Commission and the European
Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of Part 1 of EN 13263.
EN 13263 consists of the following parts, under the general title Silica fume for concrete:
Part 1: Definitions, requirements and conformity criteria;
Part 2: Conformity evaluation.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
3
---------------------- Page: 5 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
1 Scope
This part of EN 13263 specifies the scheme for the evaluation of conformity of silica fume to EN 13263-1, including
certification of conformity by a certification body.
This European Standard provides technical rules for production control by the manufacturer, including autocontrol
testing of samples, and for the tasks of the certification body. It also provides rules for actions to be followed in the
event of non-conformity and the procedure for the certification of conformity.
2 Normative references
The following referenced documents are indispensable for the application of this European Standard. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
EN 196-1, Methods of testing cement — Part 1: Determination of strength;
EN 196-2; Methods of testing cement - Part 2: Chemical analysis of cement
EN 196-7:1989, Methods of testing cement — Part 7: Methods of taking and preparing samples of cement;
EN 206-1, Concrete - Part 1: Specification, performance, production and conformity
EN 13263-1:2005, Silica fume for concrete — Part 1: Definitions, requirements and conformity criteria.
3 Terms and definitions
For the purposes of this European Standard, the following terms and definitions apply.
3.1
activity index
measurement of the effect of silica fume on the compressive strength of mortar
3.2
allowable probability of acceptance
CR
for a given sampling plan, the allowed probability of acceptance of silica fume with a characteristic value outside
the specified characteristic value
3.3
autocontrol
continuous statistical quality control of the silica fume based on the testing of samples taken by the manufacturer at
point(s) of release from the silica fume production plant
3.4
autocontrol testing
continual testing by the manufacturer of silica fume spot samples taken at the point(s) of release from the
production plant
3.5
certificate of conformity to EN 13263-1
document issued under the rules of a certain scheme for the evaluation of conformity indicating that adequate
confidence is provided that a silica fume is in conformity with EN 13263-1
4
---------------------- Page: 6 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
3.6
certification
procedure by which a third party gives written assurance that a product, process or service conforms to specified
requirements
[EN 45020:1998]
3.7
certification body
impartial body, governmental or non-governmental, possessing the necessary competence and responsibility to
carry out conformity certification according to given rules of procedure and management
3.8
certified silica fume
silica fume for which a certificate of conformity (see 3.5) has been issued
3.9
characteristic value
value having a prescribed probability of not being attained in a hypothetical unlimited test series
[ISO 8930:1987]
NOTE Equivalent to "fractile" which is defined in ISO 3534-1.
3.10
conformity mark
protected mark applied on the basis of the certificate of conformity (see 3.5)
3.11
control period
period of production and dispatch identified for the evaluation of the autocontrol test results
3.12
densified silica fume
silica fume that has been treated to increase the bulk density by particle agglomeration, the bulk density typically
3
being above 500 kg/m
3.13
depot
bulk silica fume handling facility – not located at the production plant - used for the dispatch of silica fume –
whether in bulk or bagged – after transfer or storage where the manufacturer has full responsibility for all aspects of
the quality of the silica fume
3.14
existing production plant
production plant which is already producing silica fume under the certification scheme
3.15
factory production control
permanent internal control of silica fume production exercised by the manufacturer including internal quality control
and autocontrol testing
NOTE The required activities are stated in 4.1 to 4.3 in this part of EN 13263.
3.16
further testing of samples
testing according to 4.4 in this part of EN 13263
5
---------------------- Page: 7 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
3.17
initial period
immediate period after the first issuing of the certificate of conformity for a silica fume (see 5.6.1 in this part of
EN 13263 for duration)
3.18
intitial type testing
testing of the first audit sample according to 5.4 in this part of EN 13263
3.19
inspection body
impartial body having the organization, staffing, competence and integrity to perform according to specified criteria
functions such as assessing, recommending for acceptance and subsequent audit of manufacturers´ quality control
operations, and selection and evaluation of products on site or in factories or elsewhere, according to specific
criteria
3.20
new production plant
production plant which is not already producing silica fume under the certification scheme
3.21
production plant
facility used by a manufacturer for the production of silica fume:
a) silicon metal or silicon alloy production plant;
b) processing plant, for example for the selection, slurrifying, blending or densifying of silica fume.
3.22
quality control
part of quality management focused on fulfilling quality requirements
[EN ISO 9000:2000]
3.23
sampling plan
specific plan which states the (statistical) sample size(s) to be used, the percentage P on which the characteristic
k
value is based, and the allowable probability of acceptance CR
3.24
silica fume
very fine particles of amorphous silicon dioxide collected as a by-product of the smelting process used to produce
silicon metal and ferro-silicon alloys
NOTE 1 Silica fume may be processed, for example by classification, selection, blending, densifying, or slurrifying, or by a
combination of these processes, in adequate production plants. Such processed silica fume may consist of silica fumes from
different sources, each conforming to the definition given in this subclause.
NOTE 2 Other names used for silica fume are condensed silica fume and microsilica.
3.25
silica fume slurry
homogeneous, pH regulated liquid suspension of silica fume in water, typically with a dry content of 50 % by mass,
3
corresponding to about 700 kg of silica fume per m of slurry
3.26
single result limit value
value of a chemical or physical property which – for any single test result – in the case of an upper limit is not to be
exceeded or in the case of a lower limit is, as a minimum, to be reached
6
---------------------- Page: 8 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
3.27
specified characteristic value
characteristic value of a chemical or physical property which in the case of an upper limit is not to be exceeded or
in the case of a lower limit is, as a minimum, to be reached
NOTE Conformity with the specified characteristic values in EN 13263-1 is verified by the methods in 7.2 of
EN 13263-1:2005.
3.28
spot sample
sample taken at the same time and from one and the same place, relating to the intended tests. It can be obtained
by combining one or more immediately consecutive increments
[EN 196-7:1989]
3.29
test
technical operation that consists of the determination of a characteristic of a product according to a specified
procedure
[Adapted from EN 45020:1998]
3.30
test cement
selected brand of Portland cement of type CEM I, strength class 42,5 N or higher, conforming to EN 197-1 to be
used for carrying out the tests needed to evaluate conformity to the requirement of 5.3.3 in EN 13263-1:2005.
Test cement is selected by the silica fume manufacturer and is further characterized by its fineness and contents of
tricalcium aluminate and alkalis as follows:
2 2
Fineness: 300 m /kg to 400 m /kg when determined in accordance with EN 196-6;
Tricalcium aluminate: 8 % to 12 % when determined in accordance with EN 196-2;
Alkalis (Na O eqv): 0,6 % to 1,2 % when determined in accordance with EN 196-2.
2
3.31
testing laboratory
laboratory which measures, examines, tests, calibrates or otherwise determines the characteristics or performance
of materials or products
3.32
test method
specified technical procedure for performing a test
[EN 45020:1998]
3.33
type II addition
finely divided inorganic, pozzolanic or latent hydraulic material that may be added to concrete in order to improve
certain properties or to achieve special properties, see EN 206-1
3.34
undensified silica fume
silica fume taken directly from the collection filter, the bulk density typically being in the range 150 kg/m³ to
3
350 kg/m
3.35
works´ quality manual
document that provides information on the production control which is applied by a manufacturer at a particular
production plant to ensure conformity of the silica fume with the requirements of EN 13263-1.
7
---------------------- Page: 9 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
4 Tasks for the manufacturer
4.1 Factory production control
4.1.1 Concept
Factory production control means the permanent internal control of silica fume production exercised by the
manufacturer and consists of internal quality control (see 4.2) and autocontrol testing of samples of silica fume
taken at the point of release (see 4.3).
NOTE The requirements of EN 13263-2 as regards production control take account of those clauses of EN ISO 9001
which are relevant to the production, process control and testing of silica fume.
4.1.2 Works´ quality manual
The manufacturer's documentation and procedures for production control shall be described in a works´ quality
manual, which shall adequately describe, among other things:
a) quality aims and the organisational structure, responsibilities and powers of the management with regard to
product quality and the means to monitor the achievement of the required product quality and the effective
operation of the internal quality control (see 4.1.3);
b) manufacturing and quality control techniques, processes and systematic actions that will be used (see 4.2.1,
4.2.3 and 4.3.2);
c) inspections and tests that will be carried out before, during and after manufacture, and the frequency with
which they will be carried out (see 4.2.2, 4.3.1 and 4.3.3).
The works´ quality manual prepared by the manufacturer for each production plant shall include an adequate
system of documentation (see 4.1.4 and 4.3.4).
The works´ quality manual shall address and document the procedures operated to ensure that the manufactured
silica fume conforms to the technical specifications. The manual may reference associated documents which
provide further details of the autocontrol testing of samples and the internal quality control. For the purpose of this
scheme, the term works´ quality manual shall be considered to include these associated documents.
NOTE In the case of an existing quality management system according to EN ISO 9001, the certification body may
examine if the corresponding quality manual meets all the requirements of EN 13263-1 which are relevant to the production
control of silica fume. Provided all the requirements are included, this quality manual should also be applied for product
certification.
4.1.3 Management systems
4.1.3.1 Quality policy statement
The works´ quality manual shall include a statement by the management of the manufacturer defining its quality
policy, objectives and commitments to the attainment of product quality.
4.1.3.2 Management representative
The manufacturer shall appoint a management representative who, irrespective of other responsibilities, shall have
defined authority and responsibility for ensuring that the requirements of this part of EN 13263 for the evaluation of
conformity are implemented and maintained.
4.1.3.3 Internal audits and management review
In order to ensure the continuing suitability and effectiveness of the works´ quality manual to meet the requirements
of EN 13263-1, the manufacturer shall perform at least once per year:
8
---------------------- Page: 10 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
a) internal audits covering the scope of this clause 4 and 6.1;
b) manufacturer´s management review of the production control, taking into account records of the internal
audits.
4.1.3.4 Training
The works´ quality manual shall describe the measures taken to ensure that all the personnel involved in
operations that can affect internal quality control and product quality have appropriate experience or training.
Appropriate records shall be retained.
4.1.4 System of documentation
4.1.4.1 Document control
The management representative of the manufacturer shall be responsible for the control of all documents and data
related to production control and to this scheme for the evaluation of conformity.
This control shall ensure that the appropriate issues of all documents are available at essential locations, that
obsolete documents are withdrawn and that changes or modifications to any document are effectively introduced.
A master list shall be established to identify the current version of documents in order to prevent the use of non-
applicable documents.
4.1.4.2 Quality records
The manufacturer shall retain records of production control for at least the period required to comply with relevant
legislation.
4.2 Internal quality control
4.2.1 Process control
4.2.1.1 General
The works´ quality manual shall describe the parameters for process planning, process control and testing,
inspection, corrective action, verification, dispatch and the associated records.
Depending on the installation, the following measures shall be provided:
a) in all types of production plants:
1) in-process testing of silica fume properties;
2) silos or tanks of adequate capacity for storage of the silica fume produced allowing a proper
identification of the product and giving possibilities of taking spot samples at any time without prior notice;
b) additionally, in production plants using processing facilities:
1) separate and adequate storing facilities for the silica fumes to be processed;
2) controlled proportioning of the silica fumes to be processed in order to achieve the target properties of the
produced silica fume;
3) facilities for adequate homogenization of silica fume;
4) in-process testing of silica fume properties.
9
---------------------- Page: 11 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
4.2.1.2 Provisions for processing plants
In production plants for the controlled processing of silica fume, for example by selection, drying, blending,
densifying or slurrifying of silica fume, the relevant information on each consignment of incoming silica fume and all
operating steps in the process shall be documented in the works´ quality manual by the manufacturer in agreement
with the certification body. The following data shall be at least part of this documentation:
a) manufacturer and the production location from which the silica fume originates;
b) acknowledgement that the silica fume is according to 3.24;
c) in case of blending only, the properties of each incoming silica fume shall be controlled on a regular basis in
order to be able to achieve the target properties of the silica fume blend. On each incoming silica fume the
relevant properties listed in Table 1 of EN 13263-1:2005, except activity index, should be tested by the supplier
of the incoming silica fume. The minimum testing frequency should be chosen as indicated in Table 1 of
EN 13263-1:2005, "Routine situation", and should be documented in the works´ quality manual. When
blending silica fumes from production plants at different locations, each incoming silica fume shall conform to
the requirements for silicon dioxide content and specific surface according to EN 13263-1:2005, 5.2.1 and
5.3.1;
d) environmental compatibility of the blended silica fume shall be proven, as required by clause 4 of
EN 13263-1:2005;
e) densified and undensified silica fume shall not be blended together.
4.2.1.3 Control of off-specification production
The works´ quality manual shall contain procedures to ensure that off-specification production is adequately
managed.
4.2.2 Measuring and testing
4.2.2.1 Inspection, measuring and test equipment
The equipment for in-process inspection and testing shall be regularly checked and calibrated in accordance with
the procedures and frequencies laid down in the works´ quality manual.
4.2.2.2 Inspection and test status
Procedures for the inspection and test status through the stages of manufacture shall be detailed in the works´
quality manual. These shall include procedures for the control of off-specification intermediate materials.
To ensure that only silica fume conforming to EN 13263-1 is conveyed to the silo, samples shall be taken from
appropriate places prior to the silo for certified silica fume in agreement with the certification body. The sampling
places shall be laid down in the works´ quality manual. Spot samples shall be taken for the determination of
specific surface and loss on ignition in agreement with the certification body.
4.2.3 Handling, storage, packaging and delivery
The works´ quality manual shall describe the precautions taken for the protection of the quality of the silica fume
while under the responsibility of the manufacturer. It shall include a description of the procedures used at depots.
Delivery documentation shall allow traceability to the production plants or depots.
10
---------------------- Page: 12 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
4.3 Autocontrol testing of samples
4.3.1 Sampling and testing
The manufacturer shall operate a system of autocontrol testing for the certified silica fume. This system shall be
used to demonstrate conformity to the requirements in clause 7 of EN 13263-1:2005. The properties to be tested,
the testing methods, the minimum frequency of autocontrol testing and the conformity criteria shall be in
accordance with the basic requirements given in clause 7 of EN 13263-1:2005. For silica fumes not being
dispatched continuously, the frequency of testing and the point of sampling shall be as specified in the works'
quality manual.
All test data shall be documented.
4.3.2 Corrective action
The works´ quality manual shall document procedures for the review and adjustment of the production control in
case of non-conformity (see 6.1).
The actions taken in the event of non-conformity shall be recorded in a report subject to inspection during the
management review.
In the event of silica fume yielding a test result not conforming to the single result limit value conformity criteria
specified in EN 13263-1, the manufacturer shall immediately determine the affected quantity, take appropriate
action to prevent the dispatch of this quantity and inform the affected customer if such silica fume has been
released. In addition, the manufacturer shall immediately determine the causes of such non-conformity, take
corrective actions and undertake a review of all relevant production control procedures. All such actions and
findings shall be appropriately recorded in a report subject to inspection during the management review.
NOTE The certification body may require to be kept informed of these actions and findings.
4.3.3 Measuring and test equipment for autocontrol testing
The equipment used for autocontrol testing shall be regularly checked and calibrated in accordance with
procedures and frequencies laid down in the works´ quality manual.
The works´ quality manual shall document procedures to ensure that all personnel involved in autocontrol testing
have appropriate experience and training. Appropriate records shall be retained.
4.3.4 Quality records
The manufacturer shall retain records of the autocontrol test results and appropriate records on test equipment for
at least the period required to comply with relevant legislation.
4.4 Further testing of samples
Once in a two-years period the properties listed in EN 13263-1:2005 Table 1 shall be further tested. The results of
this further testing shall not be used for the evaluation of conformity according to EN 13263-1:2005, 7.2.
NOTE The manufacturer may use this further testing for control of his testing procedures by using other personnel or other
equipment or in other ways let the testing deviate from the testing according to 7.1.1, but still be within the requirements of the
standard for the test method. If other methods than the reference methods are used for the autocontrol testing (see
EN 13263-1:2005 5.1), the further testing may be used to check the continued equivalence of the test methods.
11
---------------------- Page: 13 ----------------------
SIST EN 13263-2:2005
EN 13263-2:2005 (E)
5 Tasks for the certification body
5.1 General
The certification body (see 3.7) has responsibility for three separate functions – certification, inspection and testing.
These three functions may be carried out by one body or by more than one body. The inspection function may be
carried out by an inspection body (see 3.19) and the testing function by a testing laboratory (see 3.31). Reference
to the certification body includes reference to any sub-bodies it has.
5.2 Surveillance, assessment and acceptance of the factory production control
5.2.1 Inspection tasks
The inspection tasks include surveillance, assessment and acceptance of the production control operated by the
manufacturer. Inspection shall include checking that any major change in the works´ quality manual which is
relevant to the production control of silica fume has been reported to the certification body by the manufacturer
within one month of its implementation.
Inspection shall verify that the production control complies with the requirements as described in clause 4 and has
been carried out according to the works´ quality manual.
5.2.2 Frequency of inspections
The inspections shall be carried out at least once per year and the certification body shall inform the manufacturer
in advance when an inspection is to be made.
5.2.3 Reports
Following each inspection, a confidential report shall be prepared and sent to the manuf
...