SIST EN 61754-6:2014
(Main)Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 6: Type MU connector family
Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 6: Type MU connector family
This part of IEC 61754 defines the standard interface dimensions for type MU family of connectors.
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Steckgesichter von Lichtwellenleiter-Steckverbindern - Teil 6: Bauart MU-Steckverbinderfamilie
Dispositifs d'interconnexion et composants passifs à fibres optiques - Interfaces de connecteurs pour fibres optiques - Partie 6: Famille de connecteurs de type MU
L'IEC 61754-6:2013 définit les dimensions d'interfaces normalisées pour la famille de connecteurs de type MU. Cette deuxième édition annule et remplace la première édition parue en 1997 dont elle constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
- ajout de références de normes;
- révision de la compatibilité d'accouplement.
Mots clés: les dimensions d'interfaces normalisées pour la famille de connecteurs de type MU
Optični spojni elementi in pasivne komponente - Vmesniki optičnih konektorjev - 6. del: Konektorska družina vrste MU (IEC 61754-6:2013)
Ta del standarda IEC 61754 določa standardne dimenzije vmesnikov za konektorsko družino vrste MU.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Lichtwellenleiter - Verbindungselemente und passive Bauteile - Steckgesichter von Lichtwellenleiter-Steckverbindern - Teil 6: Bauart MU-SteckverbinderfamilieFibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 6: Type MU connector family33.180.20Fibre optic interconnecting devicesICS:Ta slovenski standard je istoveten z:EN 61754-6:2013SIST EN 61754-6:2014en01-januar-2014SIST EN 61754-6:2014SLOVENSKI
STANDARDSIST EN 61754-6:1999/A2:2005SIST EN 61754-6:1999/A1:2002SIST EN 61754-6:19991DGRPHãþD
SIST EN 61754-6:2014
EUROPEAN STANDARD EN 61754-6 NORME EUROPÉENNE
EUROPÄISCHE NORM November 2013
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2013 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61754-6:2013 E
ICS 33.180.20 Supersedes EN 61754-6:1997 + A1:2001 + A2:2005
English version
Fibre optic interconnecting devices and passive components -
Fibre optic connector interfaces -
Part 6: Type MU connector family (IEC 61754-6:2013)
Dispositifs d'interconnexion et composants passifs à fibres optiques -
Interfaces de connecteurs à fibres optiques (CEI 61754-6:2013)
Lichtwellenleiter -
Verbindungselemente und passive Bauteile - Steckgesichter von Lichtwellenleiter-Steckverbindern -
Teil 6: Bauart MU-Steckverbinderfamilie (IEC 61754-6:2013)
This European Standard was approved by CENELEC on 2013-08-26. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
SIST EN 61754-6:2014
EN 61754-6:2013 - 2 -
Foreword The text of document 86B/3627/FDIS, future edition 2 of IEC 61754-6, prepared by subcommittee 86B “Fibre optic interconnecting devices and passive components” of IEC/TC 86 "Fibre optics" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61754-6:2013. The following dates are fixed: • latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-05-26 • latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2014-08-26
This document supersedes EN 61754-6:1997 + A1:2001 + A2:2005. EN 61754-6:2013 includes the following significant technical changes with respect to EN 61754-6:1997 + A1:2001 + A2:2005 : a) addition of standard references; b) revision of intermateability. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights.
Endorsement notice The text of the International Standard IEC 61754-6:2013 was approved by CENELEC as a European Standard without any modification.
SIST EN 61754-6:2014
- 3 - EN 61754-6:2013
Annex ZA
(normative)
Normative references to international publications with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
NOTE
When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies.
Publication Year Title EN/HD Year
IEC 61755-3-1
Fibre optic interconnecting devices and passive components -Fibre optic connector optical interfaces -
Part 3-1:Connectors with 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrule, non-angled single mode non-dispersion shifted fibres prEN 61755-3-11)
IEC 61755-3-2
Fibre optic interconnecting devices and passive components -Fibre optic connector optical interfaces -
Part 3-2: Connectors with 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrule, angled single mode non-dispersion shifted fibres prEN 61755-3-21)
1)
At draft stage. SIST EN 61754-6:2014
SIST EN 61754-6:2014
IEC 61754-6 Edition 2.0 2013-07 INTERNATIONAL STANDARD Fibre optic interconnecting devices and passive components – Fibre optic connector interfaces –
Part 6: Type MU connector family
INTERNATIONAL ELECTROTECHNICAL COMMISSION XC ICS 33.180.20 PRICE CODE ISBN 978-2-8322-1010-9
® Registered trademark of the International Electrotechnical Commission ®
Warning! Make sure that you obtained this publication from an authorized distributor. SIST EN 61754-6:2014
– 2 – 61754-6 © IEC:2013(E)
CONTENTS FOREWORD . 5 1 Scope . 7 2 Normative references . 7 3 Description . 7 4 Interfaces . 7 Annex A (informative)
Configuration of type MU-A connector set . 74 Annex B (informative)
Configuration of type MU-B connector set . 75 Annex C (informative)
Floating 2-port connector plug . 76 Bibliography . 77
Figure 1 – Simplex plug connector interface – Push/pull . 11 Figure 2 – 4,5 mm duplex plug connector interface – Push/pull . 14 Figure 3 – Simplex adaptor connector interface – Push/pull . 17 Figure 4 – Gauge pin for resilient alignment sleeve . 19 Figure 5 – 4,5 mm duplex adaptor connector interface – Push/pull . 20 Figure 6 – 8-port adaptor connector interface – Push/pull . 23 Figure 7 – Plug connector interface – For printed board housings . 25 Figure 8 – Sleeve holder interface . 27 Figure 9 – 2-port backplane housing interface. 30 Figure 10 – 2-port printed board housing interface . 34 Figure 11 – 8-port backplane housing interface . 37 Figure 12 – 8-port printed board housing interface . 41 Figure 13 – Simplex active device receptacle interface . 43 Figure 14 – Detail of the mechanical stop for rigid bore alignment feature. 45 Figure 15 – 4,5 mm duplex active device receptacle interface . 46 Figure 16 – Detail of the mechanical stop for rigid bore alignment feature. 48 Figure 17 – 6,25 mm duplex active device receptacle interface . 49 Figure 18 – Detail of the mechanical stop for rigid bore alignment feature. 51 Figure 19 – Plug connector interface for printed board housings, APC . 53 Figure 20 – Simplex plug connector interface – Push/pull, APC . 56 Figure 21 – 4,5 mm duplex plug connector interface – Push/pull, APC . 59 Figure 22 – 6,25 mm duplex plug connector interface – Push/pull, APC . 62 Figure 23 – 6,25 mm duplex plug connector interface – Push/pull . 64 Figure 24 – 6,25 mm duplex adaptor connector interface . 67 Figure 25 – Horizontal duplex plug connector interface – Push/pull . 69 Figure 26 – Horizontal duplex adaptor connector interface . 72 Figure A.1 – Configuration of type MU-A connector set . 74 Figure B.1 – Configuration of type MU-B connector set . 75 Figure C.1 – Floating 2-port connector plug . 76
Table 1 – MU-A connector set . 9 SIST EN 61754-6:2014
61754-6 © IEC:2013(E) – 3 –
Table 2 – MU-B connector set . 9 Table 3 – MU receptacles . 10 Table 4 – Dimensions of the simplex plug connector interface . 12 Table 5 – Grade . 13 Table 6 – Dimensions of the 4,5 mm duplex plug connector interface . 15 Table 7 – Grade . 16 Table 8 – Dimensions of the simplex adaptor connector interface . 18 Table 9 – Grade . 18 Table 10 – Gauge pin dimensions . 19 Table 11 – Dimensions of the 4,5 mm duplex adaptor connector interface . 21 Table 12 – Grade . 22 Table 13 – Dimensions of the 8-port adaptor connector interface . 24 Table 14 – Grade . 24 Table 15 – Dimensions of the plug connector interface . 26 Table 16 – Grade . 26 Table 17 – Dimensions of the sleeve holder interface . 28 Table 18 – Grade . 28 Table 19 – Dimensions of the 2-port backplane housing interface) . 31 Table 20 – Grade . 32 Table 21 – Dimensions of the 2-port printed board housing interface . 35 Table 22 – Dimensions of the 8-port backplane housing interface . 38 Table 23 – Grade . 39 Table 24 – Dimensions of the 8-port printed board housing interface . 42 Table 25 – Dimensions of the simplex active device receptacle interface . 44 Table 26 – Alignment feature grade . 45 Table 27 – Dimensions of the mechanical stop for rigid bore alignment feature . 45 Table 28 – Mechanical stop feature grade. 46 Table 29 – Dimensions of the 4,5 mm duplex active device receptacle interface . 47 Table 30 – Alignment feature grade . 48 Table 31 – Dimensions of the mechanical stop for rigid bore alignment feature . 48 Table 32 – Mechanical stop feature grade. 49 Table 33 – Dimensions of the 6,25 mm duplex active device receptacle interface . 50 Table 34 – Alignment feature grade . 51 Table 35 – Dimensions of the mechanical stop for rigid bore alignment feature . 51 Table 36 – Mechanical stop feature grade. 52 Table 37 – Dimensions of the plug connector interface for printed board housings, APC . 54 Table 38 – Dimensions of the simplex plug connector interfaces, APC . 57 Table 39 – Dimensions of the 4,5 mm duplex plug connector interfaces, APC . 60 Table 40 – Dimensions of the 6,25 mm duplex plug connector interface, APC. 63 Table 41 – Dimensions of the 6,25 mm duplex plug connector interface . 65 Table 42 – Grade . 66 Table 43 – Dimensions of the 6,25 mm duplex adaptor connector interface . 68 Table 44 – Grade . 68 SIST EN 61754-6:2014
– 4 – 61754-6 © IEC:2013(E)
Table 45 – Dimensions of the horizontal duplex plug connector interface . 70 Table 46 – Grade . 71 Table 47 – Dimensions of the horizontal duplex adaptor connector interface . 73 Table 48 – Grade . 73 Table C.1 – Dimensions table for 2-port connector plug . 76
SIST EN 61754-6:2014
61754-6 © IEC:2013(E) – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION ____________
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
FIBRE OPTIC CONNECTOR INTERFACES –
Part 6: Type MU connector family
FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61754-6 has been prepared by subcommittee 86B: Fibre optic interconnecting devices and passive components, of IEC technical committee 86: Fibre optics. This second edition cancels and replaces the first edition published in 1997 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of standard references; b) revision of intermateability. SIST EN 61754-6:2014
– 6 – 61754-6 © IEC:2013(E)
The text of this standard is based on the following documents: FDIS Report on voting 86B/3627/FDIS 86B/3662/RVD
Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. A list of all parts of the IEC 61754 series, under the general title Fibre optic interconnecting devices and passive components – Fibre optic connector interfaces,
can be found on the IEC website. Future standards in this series will carry the new general title as cited above. Titles of existing standards in this series will be updated at the time of the next edition. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to the specific publication. At this date, the publication will be
• reconfirmed, • withdrawn, • replaced by a revised edition, or • amended. A bilingual version of this publication may be issued at a later date.
SIST EN 61754-6:2014
61754-6 © IEC:2013(E) – 7 –
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
FIBRE OPTIC CONNECTOR INTERFACES –
Part 6: Type MU connector family
1 Scope This part of IEC 61754 defines the standard interface dimensions for type MU family of connectors. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61755-3-1, Fibre optic connector optical interfaces – Part 3-1:Optical interface, 2,5 mm and 1,25 mm
diameter cylindrical full zirconia PC ferrule,
single mode fibre IEC 61755-3-2, Fibre optic connector optical interfaces – Part 3-2: Optical interface, 2,5 mm and 1,25 mm diameter
cylindrical full zirconia ferrules for 8 degrees angled-PC single mode fibres 3 Description The parent connector for type MU connector family is a miniature single-position plug which is characterized by a cylindrical, spring-loaded butting ferrule(s) of a 1,25 mm typical diameter, and a push-pull coupling mechanism. The optical alignment mechanism of the connectors is of a rigid hole or a resilient sleeve style. This part 6 type MU connector family defines the standard interface dimensions of active device receptacles for the type MU connectors. The receptacles are used to retain the connector plugs and mechanically maintain the optical datum target of the plugs at a defined position within the receptacle housings. 4 Interfaces This standard contains the following standard interfaces. Interface IEC 61754-6-1: Simplex plug connector interface – Push/pull (See Figure 1) Interface IEC 61754-6-2: 4,5 mm duplex plug connector interface – Push/pull (See Figure 2) Interface IEC 61754-6-3: Simplex adaptor connector interface – Push/pull (See Figure 3) Interface IEC 61754-6-4: 4,5 mm duplex adaptor connector interface – Push/pull (see Figure 5) Interface IEC 61754-6-5: 8-port adaptor connector interface – Push/pull (See Figure 6) Interface IEC 61754-6-6: Plug connector interface – for printed board housings (See Figure 7) Interface IEC 61754-6-7: Sleeve holder interface – for printed board housings
(See Figure 8) Interface IEC 61754-6-8: 2-port backplane housing interface – Self-retentive (See Figure 9) SIST EN 61754-6:2014
– 8 – 61754-6 © IEC:2013(E)
Interface IEC 61754-6-9: 2-port printed board housing interface – Self-retentive (See Figure 10) Interface IEC 61754-6-10: 8-port backplane housing interface – Self-retentive (See Figure 11) Interface IEC 61754-6-11 8-port printed board housing interface – Self-retentive (See Figure 12) Interface IEC 61754-6-12: Simplex active device receptacle interface – for PC connector plug (See Figure 13) Interface IEC 61754-6-13: 4,5 mm duplex active device receptacle interface – for PC connector plug (See Figure 15) Interface IEC 61754-6-14: 6,25 mm duplex active device receptacle interface – for PC connector plug (See Figure 17) Interface IEC 61754-6-15: Plug connector interface – for printed board housings, APC 8 degrees (See Figure 19) Interface IEC 61754-6-16: Simplex plug connector interface – Push/pull, APC 8 degrees
(See Figure 20) Interface IEC 61754-6-17: 4,5 mm duplex plug connector interface – Push/pull, APC 8 degrees (See Figure 21) Interface IEC 61754-6-18: 6,25 mm duplex plug connector interface – Push/pull, APC 8 degrees (See Figure 22) Interface IEC 61754-6-19: 6,25 mm duplex plug connector interface – Push/pull (See Figure 23) Interface IEC 61754-6-20: 6,25 mm duplex adaptor connector interface – Push/pull
(See Figure 24) Interface IEC 61754-6-21: Horizontal duplex plug connector interface – Push/pull (See Figure 25) Interface IEC 61754-6-22: Horizontal duplex adaptor connector interface – Push/pull
(See Figure 26) The plugs of interfaces IEC 61754-6-1, IEC 61754-6-2, IEC 61754-6-6, IEC 61754-6-19 and IEC 61754-6-21 have a ferrule(s) with a spherically polished endface, and realize physical contact (PC). The plugs of interfaces IEC 61754-6-15, IEC 61754-6-16, IEC 61754-6-17 and IEC 61754-6-18 have a ferrule(s) with a spherically polished angled endface and realize angled PC (APC). The type MU connector family comprises two types of connector set: MU-A connector set (see Annex A) and MU-B connector set (see Annex B). The MU-A connector set is a plug/adaptor configuration with a push-pull coupling mechanism. The MU-B connector set is a plug-in type back-plane connector configuration which is plug/backplane and printed board housings/plug for printed board housing/sleeve holder configuration and is equipped with a self-retentive mechanism. The type MU-A connector set consists of simplex and duplex plugs, and simplex, duplex and 8-port adaptors. The plugs are common to the backplane connector housings of the type MU-B connector set.
The type MU-B connector set consists of 2-port and 8-port backplane and printed board connector housings, simplex and duplex plugs, plug for printed board connector housings, and sleeve holder. The plug for printed board connector housing is used as a jack together with the sleeve holder. The jack is attached into the printed board connector housing. TableS 1, 2 and 3 show the intermateablitiy of the standard interfaces. It shall be noted however that in order to obtain the designated optical performance, any plug shall be connected to a counterpart plug whose ferrule end is polished to the same condition. SIST EN 61754-6:2014
61754-6 © IEC:2013(E) – 9 –
Table 1 – MU-A connector set Plugs Adaptors 61754-6-3 61754-6-4 61754-6-5 61754-6-20 61754- 6-22 61754-6-1 Mate Mate Mate Mate Mate 61754-6-2 Not mate Mate Mate Not mate Not mate 61754-6-16 Mate Mate Mate Mate Mate 61754- 6-17 Not Mate Mate Mate Not Mate Not mate 61754-6-18 Not mate Not mate Not mate Mate Not mate 61754-6-19 Not mate Not mate Not mate Mate Not mate 61754-6-21 Not mate Not mate Not mate Not mate Mate
Table 2 – MU-B connector set Plugs Connector housings Backplane connector housing Printed board connector housing 61754-6-8 61754-6-10 61754-6-9 61754-6-11 61754-6-1 Mate Mate Not mate Not mate 61754-6-2 Mate Mate Not mate Not mate 61754-6-6 with 61754-6-7
Not mate
Not mate
Mate
Mate 61754-6-15 with 61754- 6-7 Not mate Not mate Mate Mate 61754-6-16 Mate Mate Not mate Not mate 61754-6-17 Mate Mate Not mate Not mate 61754-6-18 Not mate Not mate Not mate Not mate 61754-6-19 Not mate Not mate Not mate Not mate 61754-6-21 Not mate Not mate Not mate Not mate
SIST EN 61754-6:2014
– 10 – 61754-6 © IEC:2013(E)
Table 3 – MU receptacles Plugs Receptacles 61754-6-12 61754-6-13 61754-6-14 61754-6-1 Mate Mate Mate 61754-6-2 Not mate Mate Not mate 61754-6-16 Not mate Not mate Not mate 61754-6-17 Not mate Not mate Not mate 61754-6-18 Not mate Not mate Not mate 61754-6-19 Not mate Not mate Mate 61754-6-21 Not mate Not mate Not mate
Figure 1 is an example of a simplex plug connector interface. Table 4 gives dimensions of the simplex plug connector interface and Table 5 gives the grade of the simplex plug connector interface. SIST EN 61754-6:2014
61754-6 © IEC:2013(E) – 11 –
Delatch housing Mechanical datum target IEC
1860/13
Figure 1 – Simplex plug connector interface – Push/pull
SIST EN 61754-6:2014
– 12 – 61754-6 © IEC:2013(E)
Table 4 – Dimensions of the simplex plug connector interface Reference
Dimensions Remarks Minimum Maximum A
1,249 5 mm a, see Table 5 B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35° Angle H 25° 35° Angle I 6,55 mm – b J 4,2 mm 4,5 mm c K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – b Q 1 mm 1,1 mm b and d R 2,65 mm 2,9 mm b S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AA 4,3 mm 4,4 mm
AB 3,85 mm 3,95 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Radius AE 3 mm –
AF 2,2 mm 2,3 mm
EA 32.5° 45° Angle, e EB 5 mm 30 mm Radius, f EC 0,45 mm 0,73 mm Diameter a
A chamfer or radius is allowed to a maximum depth of 0,5 mm from the ferrule endface. b
The delatch housing shall be movable toward the right and the left directions. These dimensions are given when the coupling sleeve is moved in its most right-direction position. c
The dimension J is given for the plug endface when not mated. It is noticed that the ferrule is movable by a certain axial compression force with direct contacting endfaces, and therefore the dimension J is variable. Ferrule compression force shall be 5,5 N to 6,5 N when the position of the optical datum target from the mechanical datum target is moved in the range of 3,9 mm to 4,1 mm. In addition, the dimension J shall become less than 3,25 mm with a relatively large axial compression force. d
The right-side position of Q shall become the left-side position to the mecha
...
Questions, Comments and Discussion