Animal feed - Determination of dioxins and dioxin-like PCBs by GC/HRMS and of indicator PCBs by GC/HRMS

This European Standard is applicable to the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), (together termed ‘dioxins’ (PCDD/Fs)) and dioxin-like PCBs and non dioxin-like PCBs (dl-PCBs and ndl-PCBs) in animal feeding stuffs. Collaborative studies have been carried out. The method is suitable for the determination of dioxins, dl-PCBs and ndl-PCBs at the appropriate MRL in compound feed and ingredients e.g. oil, mineral clay. The method is applicable to samples containing residues of one or more of the following dioxins, dioxin-like PCBs and indicator PCBs. The limit of quantification (LOQ) for the relevant individual congeners of dioxins/furans is 0,05 pg/g (OCDD/F = 0,1 pg/g), of non-ortho PCBs 0,05 pg/g, of mono-ortho PCBs 10 pg/g and of indicator PCBs 100 pg/g.

Futtermittel - Bestimmung von Dioxinen und dioxin-ähnlichen PCBs mittels GC/HRMS und von Indikator-PCBs mittels GC/HRMS

Diese Europäische Norm beschreibt ein Verfahren zur Bestimmung von polychlorierten Dibenzo-p-dioxinen (PCDD), polychlorierten Dibenzofuranen (PCDF) (zusammen als „Dioxine“ bezeichnet) und dioxin-ähnlicher und nicht dioxin ähnlicher PCB (dl-PCB und ndl-PCB) in Futtermitteln. Ringversuche wurden durchgeführt. Das Ver¬fahren ist für die Bestimmung von Dioxinen, dl-PCB und ndl-PCB bei der entsprechenden MRL in Mischfutter und Inhaltsstoffen, z. B. Öl, Tonmineral, geeignet. Das Verfahren ist auf Proben anwendbar, die Rückstände von einem oder mehreren der folgenden Dioxine, dioxin-ähnlichen PCB und Indikator-PCB enthalten. Die Bestimmungsgrenze (LOQ) beträgt für die relevanten einzelnen Kongeneren der Dioxine/Furane 0,05 pg/g (OCDD/F  0,1 pg/g), für non-ortho PCB 0,05 pg/g, für mono-ortho PCB 10 pg/g und 100 pg/g für Indikator PCB.
Für die Bestimmung von Dioxinen und dioxin-ähnlichen PCB kann das Verfahren, wie in der Verordnung (EG) 152/2009 für Dioxine und dl-PCB in Futtermitteln [1] festgelegt, als Bestätigungsverfahren angewendet werden. Die Bestätigungsverfahren sind Verfahren mit hochauflösender Gaschromatographie/hochauf-lösender Massenspektrometrie (HRGC/HRMS). Ist nur die Analyse der Indikator-PCB erforderlich, kann ein GC/LRMS Verfahren (z. B. EN 15741, Futtermittel — Bestimmung der OC-Pestizide und PCB’s mittels GC/MS-Verfahren [7] und EN 15742, Futtermittel — Bestimmung der OC-Pestizide und PCB’s mittels GC/ECD Verfahren [8]) angewendet werden, vorausgesetzt, dass für die zu untersuchende Matrix im relevanten Bereich die entsprechenden analytischen Leistungskriterien erfüllt werden.
Diese CEN-Norm ist in vier Module aufgeteilt, die jeweils einen Teil des gesamten Verfahrens (siehe Bild 1 und 2) wie folgt beschreiben:
a)   Modul A:   Beschreibung der Normen, die angewendet werden können;
b)   Modul B:   Beschreibung der Extraktionsverfahren;
c)   Modul C:   Beschreibung der Reinigungsverfahren;
d)   Modul D:   GC/HRMS Bestimmung.

Aliments des animaux - Dosage des dioxines, des PCB de type dioxine et des PCB indicateurs par GC/HRMS

La présente Norme européenne concerne le dosage des dibenzo-p-dioxines polychlorés (PCDD), des dibenzofuranes polychlorés (PCDF) (conjointement appelés 'dioxines' (PCDD/F)) ainsi que des PCB de type dioxine et des PCB autres que ceux de type dioxine (dl-PCB et ndl-PCB) dans les aliments des animaux. Des études comparatives ont été menées. La méthode convient au dosage des dioxines, des dl-PCB et des ndl-PCB à la LMR appropriée dans les aliments et les ingrédients composés tels que l'huile et l'argile minérale. La méthode est applicable aux échantillons contenant des résidus de dioxines, PCB de type dioxine et/ou PCB indicateurs. La limite de quantification (LOQ) est de 0,05 pg/g (OCDD/F = 0,1 pg/g) pour les congénères individuels concernés des dioxines/furanes, de 0,05 pg/g pour les PCB non-ortho, de 10 pg/g pour les PCB mono-ortho et de 100 pg/g pour les PCB indicateurs.
Pour le dosage des dioxines et des PCB de type dioxine, le mode opératoire peut être utilisé comme méthode de confirmation, conformément aux définitions du Réglement (CE) n° 152/2009 de la Commission relatif aux dioxines et aux dl-PCB dans les aliments [6]. Les méthodes de confirmation sont les méthodes de chromatographie en phase gazeuse haute résolution/spectrométrie de masse haute résolution (HRGC/HRMS). Si seule l'analyse des PCB indicateurs est requise, une méthode GC-LRMS peut être utilisée (par exemple, EN 15741, Aliments des animaux - Détermination des pesticides organochlorés (OC) et des polychlorobiphényles (PCB) par GC/MS [1] et EN 15742, Aliments des animaux - Détermination des pesticides organochlorés (OC) et des polychlorobiphényles (PCB) par GC/ECD [2] à condition que les critères de performance analytique appropriés soient atteints dans la gamme de concentration correspondant aux aliments concernés.
La présente Norme européenne se divise en quatre modules, chacun décrivant une partie de l'ensemble du mode opératoire (voir les Figures 1 et 2) à respecter :
a)   Module A :   Description des normes susceptibles d'être utilisées ;
b)   Module B :   Description des modes opératoires d'extraction ;
c)   Module C :   Description des modes opératoires de purification ;
d)   Module D :    Dosage par GC/HRMS.
Chaque module décrit une partie de l'ensemble de la méthode ainsi que, le cas échéant, des alternatives équivalentes. Chaque module doit être considéré comme un exemple. La combinaison des modules et/ou alternatives donne un mode opératoire très souple qui est « basé sur les performances ». Il est possible de modifier la méthode si tous les critères de performance énoncés dans le Règlement (CE) n° 152/2009 de la Commission [6] sont remplis.
En cas d'écart par rapport à la méthode décrite, la combinaison de modules doit être enregistrée dans le cadre des procédures AQ/CQ des laboratoires accrédités et il convient que cette combinaison soit disponible sur demande.

Krma - Določevanje dioksinov in dioksinu podobnih PCB z GC/HRMS in indikatorjev PCB z GC/HRMS

Ta evropski standard se uporablja za določevanje polikloriranih dibenzo-p-dioksinov (PCDD), polikloriranih dibenzofuranov (PCDF) (s skupnim imenom »dioksini« (PCDD/F)) ter dioksinom podobnih polikloriranih bifenilov in dioksinom nepodobnih polikloriranih bifenilov (dl-PCBs in ndl-PCBs) v živalski krmi. Izvedene so bile medlaboratorijske študije. Metoda je primerna za določevanje dioksinov, dioksinom podobnih polikloriranih bifenilov in dioksinom nepodobnih polikloriranih bifenilov v krmi in sestavinah, na primer olju ter mineralni glini, pri ustrezni mejni vrednosti ostankov. Metoda se uporablja za vzorce, ki vsebujejo ostanke enega ali več naslednjih dioksinov, dioksinom podobnih polikloriranih bifenilov ter indikatorskih polikloriranih bifenilov. Meja kvantifikacije (LOQ) za ustrezne posamezne analoge dioksinov/furanov je 0,05 pg/g (OCDD/F = 0,1 pg/g), za neorto poliklorirane bifenile 0,05 pg/g, za monoorto poliklorirane bifenile 10 pg/g, za indikatorske poliklorirane bifenile pa 100 pg/g.

General Information

Status
Withdrawn
Public Enquiry End Date
14-Apr-2011
Publication Date
01-Aug-2012
Withdrawal Date
09-Feb-2020
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
10-Feb-2020
Due Date
04-Mar-2020
Completion Date
10-Feb-2020

Relations

Buy Standard

Standard
EN 16215:2012
English language
53 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.QFuttermittel - Bestimmung von Dioxinen und dioxin-ähnlichen PCBs mittels GC/HRMS und von Indikator-PCBs mittels GC/HRMSAnimal feed - Determination of dioxins and dioxin-like PCBs by GC/HRMS and of indicator PCBs by GC/HRMS65.120KrmilaAnimal feeding stuffsICS:Ta slovenski standard je istoveten z:EN 16215:2012SIST EN 16215:2012en,fr,de01-september-2012SIST EN 16215:2012SLOVENSKI
STANDARD



SIST EN 16215:2012



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16215
April 2012 ICS 65.120 English Version
Animal feeding stuffs - Determination of dioxins and dioxin-like PCBs by GC/HRMS and of indicator PCBs by GC/HRMS
Aliments des animaux - Dosage des dioxines, des PCB de type dioxine et des PCB indicateurs par GC/HRMS
Futtermittel - Bestimmung von Dioxinen und dioxin-ähnlichen PCBs mittels GC/HRMS und von Indikator-PCBs mittels GC/HRMS This European Standard was approved by CEN on 9 March 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16215:2012: ESIST EN 16215:2012



EN 16215:2012 (E) 2 Contents Page Foreword . 31Scope . 42Normative references . 63Terms and definitions . 64Principle . 75Reagents . 76Apparatus . 97Sampling . 98Preparation of test sample . 99Procedure . 910Extraction .1011Clean up .1312Module D: Gas chromatograph-high resolution mass spectrometer (GC-HRMS) .2713Calculation and expression of results .2914Precision .3415Test report .36Annex A (informative)
Description of PTV injection system .37Annex B (informative)
Description of standards and concentration of the standard solutions .39Annex C (informative)
Example of automated procedure .46Annex D (informative)
Mass spectrometer (MS) .48Annex E (informative)
Use of additional clean up after fractionation using a small multi-layer silica column .52Bibliography .53 SIST EN 16215:2012



EN 16215:2012 (E) 3 Foreword This document (EN 16215:2012) has been prepared by Technical Committee CEN/TC 327 “Animal feeding stuffs”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2012, and conflicting national standards shall be withdrawn at the latest by October 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 16215:2012



EN 16215:2012 (E) 4 1 Scope This European Standard is applicable to the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), (together termed ‘dioxins’ (PCDD/Fs)) and dioxin-like PCBs and non dioxin-like PCBs (dl-PCBs and ndl-PCBs) in animal feeding stuffs. Collaborative studies have been carried out. The method is suitable for the determination of dioxins, dl-PCBs and ndl-PCBs at the appropriate MRL in compound feed and ingredients e.g. oil, mineral clay. The method is applicable to samples containing residues of one or more of the following dioxins, dioxin-like PCBs and indicator PCBs. The limit of quantification (LOQ) for the relevant individual congeners of dioxins/furans is 0,05 pg/g (OCDD/F = 0,1 pg/g), of non-ortho PCBs 0,05 pg/g, of mono-ortho PCBs 10 pg/g and of indicator PCBs 100 pg/g. For determination of dioxins and dioxin-like PCBs, the procedure can be used as confirmatory method as defined by Commission Regulation (EC) No 152/2009 for dioxins and dl-PCB in feed [6]. Confirmatory methods are high-resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) methods. If only the analysis of indicator PCBs is required, a GC-LRMS method can be used (e.g. EN 15741 Animal feeding stuffs - Determination of OC-pesticides and PCBs by GC/MS [1] and EN 15742 Animal feeding stuffs - Determination of OC-pesticides and PCBs by GC/ECD [2]) provided that appropriate analytical performance criteria are met in the relevant range for the matrix of interest. This European Standard is split into four modules each describing a part of the whole procedure (see Figure 1 and Figure 2) to be followed: a) Module A: Description of standards which might be used; b) Module B: Description of extraction procedures; c) Module C: Description of clean up procedures; d) Module D:
GC/HRMS determination. Each module describes a part of the whole method as well as, when applicable, alternatives which should be equivalent. Each module has to be regarded as an example. Combining modules and/or alternatives gives a highly flexible procedure which is "performance based". It is permitted to modify the method if all performance criteria laid down in Commission Regulation (EC) No 152/2009 [6] are met. Any deviation of the described method, combination of modules needs to be recorded as part of the QA/QC procedures of accredited laboratories and should be available on request.
SIST EN 16215:2012



EN 16215:2012 (E) 5
= optional Figure 1 — Flow scheme for the determination of Dioxins, dl-PCBs and Indicator PCBs in feed SIST EN 16215:2012



EN 16215:2012 (E) 6
= optional Figure 2 — Flow scheme for the determination of Dioxins, dl-PCBs and Indicator PCBs in oil / fat 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. prEN ISO 6498, Animal feeding stuffs
Guidelines for sample preparation (ISO/DIS 6498) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 limit of detection smallest measured content, from which it is possible to deduce the presence of the analyte with reasonable statistical certainty Note 1 to entry: The limit of detection is numerically equal to three times the standard deviation of the mean of blank determinations (n > 10). SIST EN 16215:2012



EN 16215:2012 (E) 7 3.2 limit of quantification lowest content of the analyte that can be measured with reasonable statistical certainty Note 1 to entry: If both accuracy and precision are constant over a concentration range around the limit of detection, then the limit of quantification is numerically equal to six times the standard deviation of the mean of blank determinations (n > 10). Note 2 to entry: For dl-PCBs and PCDD/F: Use correct definition for limit of quantification for each congener as in Commission Regulation (EC) No 152/2009 [6]. Note 3 to entry: Limit of quantification should be in the range of about one fifth of the level of interest. 3.3 feed additives substances that comply with the definition of feed additives given in the Commission Regulation (EC) No 1831/2003 [7] 3.4 upper, middle and lower bound upper, middle and lower bound results for WHO-PCDD/F-TEQ and WHO-PCB-TEQ are defined as follows: upper bound concentrations are calculated assuming that all values of the different congeners less than the limit of quantification are equal to the limit of quantification; for lower bound: LOQ = 0 and middle bound: ½ LOQ is used 4 Principle A test portion of animal feeding stuff or ingredient is fortified with 13C labelled internal standards (dioxins, furans, dioxin-like PCBs and indicator PCBs) and extracted using a manual or an automated method. After automated or manual clean up an aliquot of the extract is concentrated and injected into a GC-HRMS using a split less injector (an alternative here is PTV injection (Programmed Temperature Vaporizer injection) see NOTE.
Quantification is based on isotope dilution. If only indicator PCBs are required, they can be determined with GC-LRMS (e.g. according to EN 15741 Animal feeding stuffs - Determination of OC-pesticides and PCBs by GC/MS [1] and EN 15742 Animal feeding stuffs - Determination of OC-pesticides and PCBs by GC/ECD [2])
Preconditions of combining modules for extraction and clean-up are: a) for each extraction module an equal sample intake of 10 g for feed or feed ingredients with a fat content ≤ 25 % or 2,5 g fat or oil is required; b) in order to achieve the required LOQ for dioxins a final volume of 10 µl in combination with an injection volume of 2 µl is required. If a different injection volume is applied, the final volume has to be adjusted directly proportional. NOTE In case more sensitivity is necessary or less volume reduction is wanted, injection of a larger volume by PTV (an example is described in Annex A) or higher sample intake is possible (see also 9.2.2 NOTE). 5 Reagents Use only reagents of recognized analytical grade and with purity suitable for dioxin and PCB residue analysis. Check the purity of the reagents and reference materials (e.g. standard solutions) by performing a blank test under the same conditions as used in the method. The chromatogram should not show any interfering impurity at the retention time of compounds of interest. SIST EN 16215:2012



EN 16215:2012 (E) 8 WARNING — The use of this European Standard can involve hazardous materials, operations and equipment. This standard does not purport to address all the safety problems associated with its use. It is the responsibility of the user of this European Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. 5.1 Dioxins, furans, non-ortho PCBs, mono-ortho PCBs and indicator PCBs and their labelled analogues:  13C-spiking solution for PCDD/F (internal standard);  13C-spiking solution for PCB (internal standard);  calibration solutions PCDD/F;  calibration solutions PCB;  recovery standard PCDD/F;  recovery standard PCB. See Annex B: Description of standards and concentration of the standard solutions. SIST EN 16215:2012



EN 16215:2012 (E) 9 6 Apparatus All technical descriptions are examples of possible system setups and parameters and have to be scaled or adopted to the user’s equipment.
6.1 Evaporator, suitable for volumes up to 200 ml and inlet for nitrogen gas. 6.2 Evaporator tubes, endpoint about 0,5 ml. 6.3 Homogeniser 6.4 Pasteur pipette, borosilicate glass, 150 mm. 6.5 Vortexmixer 6.6 Measuring cylinder, borosilicate glass, 100 ml, 2 ml graduations with a precision of ± 0,5 ml. 6.7 Measuring cylinder, borosilicate glass, glass-stoppered, 25 ml, 1 ml graduation with a precision of ± 0,5 ml graduation and 50 ml, 2 ml graduation
with a precision of ± 0,5 ml graduation. 7 Sampling The sample should be truly representative and not damaged or changed during transport or storage. Sampling is not part of the method specified in this European Standard. A recommended sampling method is given in EN ISO 6497 [3]. 8 Preparation of test sample Prepare the test sample in accordance with prEN ISO 6498. Dry or low moisture products such as cereals and cereal products, mixed feeds, and hay should be ground carefully so that it passes completely through a sieve with 1 mm apertures. Mix thoroughly. High moisture products such as grasses and silages and liquid feed should be (freeze-)dried and after that ground carefully so that it passes completely through a sieve with 1 mm apertures. Mix thoroughly. Oil / fat are directly dissolved in n-hexane. 9 Procedure 9.1 General Analyse the following samples in each series:  procedure blank (n = 1);  (certified) reference material at appropriate level or a home made reference sample;  all samples (maximum 20). The procedure blank should be free of contaminants at or above the limits of quantification. SIST EN 16215:2012



EN 16215:2012 (E) 10 9.2 Animal feed stuff sample and oil/fat sample 9.2.1 10 g animal feed stuff sample (12 % moisture content) Weigh an appropriate amount, e.g. 10,0 g (± 0,10 g) of the prepared test sample into a 100 ml glass vial. Sample amount is based on 12 % moisture content. If extracting by Pressurized Fluid Extraction (PFE), add 3 g diatomaceous earth and mix thoroughly. Fortify the sample with 500 µl 13C-DIOXNOP-2 (Annex B, B.2.31) and 500 µl 13C-MOPIP-2 (Annex B, B.2.33) and incubate until solvent has been evaporated and continue at 10.2 (module BI) or 10.3 (module BII). For samples with more than 25 % fat, the sample intake has to be reduced proportionally. 9.2.2 2,5 g oil/fat sample Weigh an appropriate amount, e.g. 2,5 g (± 0,10 g) of the oil/fat sample into graduated cylinder of 25 ml (6.7). Fortify the sample with 500 µl 13C-DIOXNOP-2 (Annex B, B.2.31) and 500 µl 13C-MOPIP-2 (Annex B, B.2.33). Fill the graduated cylinder to 25 ml with n-hexane. Close the graduated cylinder with a glass stopper and mix thoroughly. Continue sample clean up procedure at paragraph 11.2 (module CI) or 11.3 (module CII) or 11.5 (module CIII). NOTE Calculation in 13.4 is based on sample intake of 10 g for feed with fat content of ≤ 25 % and 2,5 g for fat and oil. Deviations of sample intake should be taken into account in the formulas in 13.4 (M = sample intake in gram). 10 Extraction 10.1 General The sample amount used for extraction may vary from 5 g to 50 g depending on the expected level of contamination. However calculation in 13.4 is based on sample intake of 10 g for feed with fat content of
≤ 25 % and 2,5 g for fat and oil. Deviations of sample intake should be taken into account in the formula’s in 13.4 (M = sample intake in gram). The internal standard consisting of 13C-labelled congeners listed in Annex B, Table B.1 shall be added directly onto the sample before extraction, or onto the oil sample before clean up. The extraction procedure is carried out using Pressurized Fluid Extraction (PFE) with consecutively toluene and a mixture of toluene/ethanol (module BI) or Soxhlet extraction (module BII). Duration of extraction should be adjusted according to kind and amount of sample used. The minimum requirement for Soxhlet extraction is 50 extraction cycles. Other extraction techniques like microwave assisted extraction can also be used but shall be of proven equal performance. 10.2 Module BI: Extraction using automated Pressurized Fluid Extraction (PFE) system 10.2.1 Reagents and materials 10.2.1.1 Diatomaceous earth 10.2.1.2 n-Hexane, for dioxin and PCB analysis. 10.2.1.3 Toluene, for dioxin and PCB analysis. 10.2.1.4 Ethanol, for dioxin and PCB analysis. SIST EN 16215:2012



EN 16215:2012 (E) 11 10.2.1.5 Toluene/ethanol, in volume portions of 9/1. Mix 900 ml toluene (10.2.1.3) with 100 ml ethanol (10.2.1.4) thoroughly. Store at room temperature in a tightly closed bottle. The solution is tenable under these conditions for at least 1 year. 10.2.1.6 Anhydrous sodium sulphate, heated at 160 °C for at least 24 h. 10.2.1.7 Nitrogen 10.2.1.8 Silanised glass wool 10.2.2 Apparatus 10.2.2.1 Pressurized Fluid Extraction apparatus The apparatus shall be able to extract the samples at 100 °C and 10 MPa. 10.2.2.2 Pressurized Fluid Extraction cell, e.g. 30-40 ml. 10.2.2.3 Measuring cylinder, borosilicate glass, 25 ml, 1 ml graduation with a precision of ± 0,5 ml. 10.2.2.4 Funnel 10.2.2.5 Evaporator, suitable for volumes up to 200 ml and inlet for nitrogen gas. 10.2.2.6 Evaporator tubes, 0,5 ml endpoint. 10.2.3 Procedure Put the sample (9.2.1) in a Pressurized Fluid Extraction cell (10.2.2.2) and fill with diatomaceous earth (10.2.1.1) and place the extraction cell into the Pressurized Fluid Extraction apparatus (10.2.2.1). For the extraction the following parameters might be used:  temperature
100 °C;  pressure
10 MPa;  preheat
0 min;  heat
5 min;  static
15 min;  flush
40 vol. % of extraction cell, e.g. for a 33 ml extraction cell = 13,2 ml;  purge
300 s;  cycles
3;  solvent cycle 1
toluene (10.2.1.3);  solvent cycle 2 and 3
toluene/ethanol in volume portions of 9/1 (10.2.1.5). Combine solvent obtained with each cycle and filter over a funnel (10.2.2.4) equipped with a glass wool plug (10.2.1.8) and 5 g pre-dried sodium sulphate (10.2.1.6). Evaporate the filtrate using an evaporator (10.2.2.5) SIST EN 16215:2012



EN 16215:2012 (E) 12 until an end volume of 0,5 ml. Take the sample extract from the evaporator tube and place in a glass-stoppered graduated 25 ml cylinder (6.7) and wash the evaporator tube 5 times with 4 ml n-hexane each time (i.e. 20 ml total) (10.2.1.2). The n-hexane is added to graduated cylinder containing the sample extract. Bring the volume to 25 ml with n-hexane (10.2.1.2), close the graduated cylinder with the glass stopper and mix thoroughly. Continue sample clean up procedure using the automated procedure (module CI, 11.2) or at paragraph using the manual method (module CII, 11.3 or module CIII, 11.5). NOTE Comparable techniques in combination with appropriate parameters can be used provided that Commision Regulation (EC) No 152/2009 [6] is obeyed. 10.3 Module BII: Manual extraction procedure 10.3.1 Reagents and materials. 10.3.1.1 DCM, dichloromethane, for dioxin and PCB analysis. 10.3.1.2 Toluene, for dioxin and PCB analysis. 10.3.1.3 Ethanol, for dioxin and PCB analysis. 10.3.1.4 n-Hexane, for dioxin and PCB analysis. 10.3.1.5 Toluene/ethanol, in volume portions of 9/1. Mix 900 ml toluene (10.2.1.3) with 100 ml ethanol (10.2.1.4) thoroughly. Store at room temperature in a tightly closed bottle. The solution is tenable under these conditions for at least 1 year. 10.3.1.6 Anhydrous sodium sulphate, heated at 160 °C for at least 24 h. 10.3.1.7 Measuring cylinder, borosilicate glass, 25 ml, 1 ml graduation with a precision of ± 0,5 ml. 10.3.1.8 Silanised glass wool 10.3.2 Apparatus 10.3.2.1 Extraction thimbles, cleaned by extracting in soxhlet extractor for 2 h with DCM (10.3.1.1). 10.3.2.2 Recirculating cooler 10.3.2.3 Soxhlet extractor 10.3.2.4 Heating apparatus, e.g. mantle. 10.3.2.5 Anti-bumping granules 10.3.2.6 Round bottom flask (RBF), borosilicate glass, 500 ml. 10.3.2.7 Funnel, standard, 150 mm, 80 mm diameter, borosilicate glass. 10.3.2.8 Evaporator, suitable for volumes up to 200 ml and inlet for nitrogen gas. 10.3.2.9 Evaporator tubes, 0,5 ml endpoint. SIST EN 16215:2012



EN 16215:2012 (E) 13 10.3.3 Procedure Wash the soxhlet extractor (10.3.2.3) including round bottom flasks (RBF) (10.3.2.6) subsequently with toluene (10.3.1.2) and dichloromethane (DCM) (10.3.1.1). Switch on the refrigerated recirculator (10.3.2.2) and leave to cool. Put sample (9.2.1) in the prepared extraction thimble (10.3.2.1) and place thimbles (10.3.2.1) plugged with silanised glass wool (10.3.1.8) into soxhlet extractor (10.3.2.3). Add 200 ml toluene (10.3.1.2) and 3 - 6 anti-bumping granules (10.3.2.5) to the RBF (10.3.2.6) and place into heating mantle (10.3.2.4). Connect all the soxhlet extractor together including the condenser and check all seals are tight. Set the soxhlets running at a rate of 5 cycles per hour to 7 cycles per hour. Leave the soxhlets extracting for 4 h. Switch off heating mantles and allow apparatus to cool and remove the RBF containing toluene from the soxhlet apparatus. Add 200 ml toluene/ethanol (10.3.1.5) and 3 anti-bumping granules to 6 anti-bumping granules (10.3.2.5) to a new RBF (10.3.2.6) and place into heating mantle (10.3.2.4). Connect all the soxhlet equipment together including the condenser and check all seals are tight. Set the soxhlets running at a rate of 5 cycles per hour to 7 cycles per hour. Leave the soxhlets extracting for 16 h until 20 h or overnight. Switch off heating mantles and allow apparatus to cool and combine the toluene extract and the toluene/ethanol extract. Filter the soxhlet-extract through a funnel equipped with a silanised glass wool plug (10.3.1.8) and 5 g -anhydrous sodium sulphate (10.3.1.6). Evaporate the filtrate using an evaporator (6.1) until the solvent has evaporated (approximately 0,5 ml). Take the sample extract from the evaporator tube and place in a glass-stoppered graduated 25 ml cylinder (6.7) and wash the evaporator tube 5 times with 4 ml n-hexane each time (i.e. 20 ml total) (10.3.1.4). The n-hexane is added to graduated cylinder containing the sample extract. Bring the volume to 25 ml with n-hexane (10.3.1.4), close the graduated cylinder with the glass stopper and mix thoroughly. Continue sample clean up procedure using the automated procedure (module CI, 11.2) or at paragraph using the manual method (module CII, 11.3 or module CIII, 11.5). NOTE Comparable techniques, e.g. twisselmann (hot extraction) in combination with appropriate parameters can be used provided that Commision Regulation (EC) No 152/2009 [6] is obeyed. In addition, the azeotropic mixture of toluene/ethanol in volume portions of 3/7 can be used. 11 Clean up 11.1 General Clean up methods shall prepare the sample extract in an appropriate manner for the subsequent quantitative determination. Clean up procedures have to concentrate PCDDs/PCDFs and dioxin-like PCBs in the extracts and to remove interfering matrix components present in the raw extract. Below principles of frequently used clean up techniques are briefly described.  Gel permeation chromatography The interesting molecular weight range for PCDDs/PCDFs and dioxin-like PCBs of 200 g/mol to 500 g/mol can be isolated from larger molecules such as fat / oil and polymers which might overload other clean-up methods.  Multi-layer column Multi-layer column liquid chromatography using silica with different activity grades and surface modifications. Compounds with different chemical properties than PCDDs/PCDFs and dioxin-like PCBs can be removed.  Sulphuric acid treatment A direct treatment of the sample extract for removal of oxidizable coextractives with sulphuric acid is possible but is not recommended due to safety reasons. Furthermore, this has to be carried out very carefully to avoid losses of PCDDs/PCDFs and dioxin-like PCBs on the formed carboniferous surfaces. SIST EN 16215:2012



EN 16215:2012 (E) 14 This procedure is not described within this standard, but might be used for initial treatment of very dirty oil or fat samples e.g. frying oil.
 Activated carbon column Column adsorption chromatography using activated carbon may be used to separate planar PCDD/PCDF and coplanar PCB molecules from mono-ortho PCB and other interfering non-planar molecules. Additionally activated carbon can also be used to clean the PCDD/PCDDF fraction or separate non-ortho PCBs, mono-ortho PCBs and indicator PCBs.  Alumina column Column fluid chromatography on alumina of different activity grade and acidity/basicity. Interfering compounds with small differences in polarity or structure compared to PCDDs/PCDFs and dioxin-like PCBs can be removed. Additionally, alumina columns can be used to separate PCDDs/PCDFs from dioxin-like PCBs.  Florisil column Column fluid chromatography on Florisil of different activity grade can be used to separate PCDDs/PCDFs from PCBs, also dioxin-like PCBs and other interfering compounds with small differences in polarity or structure compared to PCDDs/PCDFs.  Procedure sample clean up Proven clean up procedures shall be used containing normally two or more of the above discribed techniques which can be combined in different orders. A detailed description of the automated clean up procedure is given in Module CI (automated method). In module CII and module CIII manual methods are described, where module CII describes the clean up over a mixed silica column followed by a activated naoh carbon column where non-ortho PCB, PCDDs/PCDFs are separated from mono-ortho PCBs and indicator PCBs. Module CIII describes the clean up procedure using mixed silica followed by GPC or Florisil. Other methods can also be used but shall be of proven equal performance as the methods described in modules C. 11.2 Module CI: Automated clean up 11.2.1 General The purification method consists of a comprehensive automated system. Extracts are transferred by a pump to the system and purified consecutively on an acid silica column, a neutral silica column, a basic alumina column and an activated carbon/Celite column. For the elution of the columns, custom made solvents and mixtures are used: n-hexane, n-hexane/dichloromethane in volume portions of 1/1, ethylacetate/toluene in volume portions of 1/1 and toluene. The program can be downloaded from:
http://www.rikilt.wur.nl/UK/services/Analyses/Dioxine+analysis/ [11]. After the automated procedure two fractions are obtained: mono-ortho substituted PCBs and indicator PCBs (Fraction A) and planar PCDD/Fs and non-ortho substitute PCBs (Fraction B). For additional clean up especially in case of dirty complex samples (oxidized fat/oil) a small multi layer silica column might be used. 11.2.2 Reagents and materials 11.2.2.1 Toluene, for dioxin and PCB analysis. 11.2.2.2 n-Hexane, for dioxin and PCB analysis. 11.2.2.3 Dichloromethane, for dioxin and PCB analysis. SIST EN 16215:2012



EN 16215:2012 (E) 15 11.2.2.4 Ethylacetate, for dioxin and PCB analysis. 11.2.2.5 Ethylacetate/toluene, in volume portions of 1/1. Mix 1 l ethylacetate (11.2.2.4) with 1 l toluene (11.2.2.1) thoroughly. Store at room temperature in a tightly closed bottle. The solution is tenable under these conditions for at least 1 year. 11.2.2.6 Dichloromethane/n-hexane, in volume portions of 1/1. Mix 1 l dichloromethane (11.2.2.3) with 1 l n-hexane (11.2.2.2) thoroughly. Store at room temperature in a tightly closed bottle. The solution is tenable under these conditions for at least 5 years if the weight is carefully controlled by the addition of solvent to replace any losses due to evaporation. 11.2.2.7 Iso-octane, HPLC-grade. 11.2.2.8 Sulphuric acid H2SO4, 96 %, 1,8
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.