Flexible sheets for waterproofing - Plastic and rubber damp proof sheets including plastic and rubber basement tanking sheet - Definitions and characteristics

This document specifies definitions and characteristics of flexible plastic and rubber sheets which are intended to be used as damp proofing for buildings, including basement tanking. It specifies the requirements and test methods, and provides for the evaluation of conformity of the products with the requirements of this standard.

Abdichtungsbahnen - Kunststoff- und Elastomerbahnen für die Bauwerksabdichtung gegen Bodenfeuchte und Wasser - Definitionen und Eigenschaften

Dieses Dokument legt Definitionen und Eigenschaften von Kunststoff- und Elastomerbahnen für die Bauwerksabdichtung, einschließlich gegen Bodenfeuchte und Wasser, fest. Es legt die Anforderungen und Prüfverfahren fest und enthält die Anforderungen dieser Norm für die Konformitätsbeurteilung der Produkte.

Feuilles souples d'étanchéité - Feuilles plastiques et élastomères empêchant les remontées capillaires du sol - Définitions et caractéristiques

La présente Norme européenne spécifie les définitions et les caractéristiques des feuilles souples plastiques et élastomères dont l'usage prévu consiste à empêcher les remontées capillaires du sol dans les bâtiments. Elle spécifie les exigences et les méthodes d'essai et fournit des indications relatives à l'évaluation de la conformité des produits aux exigences de la présente Norme.

Hidroizolacijski trakovi - Polimerni in elastomerni tesnilni trakovi za temelje - Definicije in lastnosti

V tem dokumentu so navedene definicije in lastnosti polimernih in elastomernih trakov, namenjenih uporabi kot tesnilni trakovi za temelje stavb. Določa zahteve in preskusne metode ter predvideva vrednotenje skladnosti proizvodov z zahtevami iz tega standarda.

General Information

Status
Withdrawn
Public Enquiry End Date
19-Dec-2011
Publication Date
01-Aug-2012
Withdrawal Date
19-Nov-2020
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
20-Nov-2020
Due Date
13-Dec-2020
Completion Date
20-Nov-2020

Relations

Buy Standard

Standard
EN 13967:2012
English language
31 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Hidroizolacijski trakovi - Polimerni in elastomerni tesnilni trakovi za temelje - Definicije in lastnostiAbdichtungsbahnen - Kunststoff- und Elastomerbahnen für die Bauwerksabdichtung gegen Bodenfeuchte und Wasser - Definitionen und EigenschaftenFeuilles souples d'étanchéité - Feuilles plastiques et élastomères empêchant les remontées capillaires du sol - Définitions et caractéristiquesFlexible sheets for waterproofing - Plastic and rubber damp proof sheets including plastic and rubber basement tanking sheet - Definitions and characteristics91.100.50Veziva. Tesnilni materialiBinders. Sealing materials01.040.91Gradbeni materiali in gradnja (Slovarji)Construction materials and building (Vocabularies)ICS:Ta slovenski standard je istoveten z:EN 13967:2012SIST EN 13967:2012en,fr,de01-september-2012SIST EN 13967:2012SLOVENSKI
STANDARDSIST EN 13967:2005/oprA2:2008SIST EN 13967:2005/A1:2007SIST EN 13967:20051DGRPHãþD



SIST EN 13967:2012



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13967
April 2012 ICS 01.040.91; 91.100.50 Supersedes EN 13967:2004English Version
Flexible sheets for waterproofing - Plastic and rubber damp proof sheets including plastic and rubber basement tanking sheet - Definitions and characteristics
Feuilles souples d'étanchéité - Feuilles plastiques et élastomères empêchant les remontées capillaires du sol - Définitions et caractéristiques
Abdichtungsbahnen - Kunststoff- und Elastomerbahnen für die Bauwerksabdichtung gegen Bodenfeuchte und Wasser - Definitionen und Eigenschaften This European Standard was approved by CEN on 23 March 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13967:2012: ESIST EN 13967:2012



EN 13967:2012 (E) 2 Contents page Foreword . 41Scope . 52Normative references . 53Terms and definitions . 64Product designation . 75Product characteristics . 75.1General . 75.2Deviation from test sample dimensions . 75.3Visible defects . 75.4Dimensions and tolerances . 75.5Thickness and mass per unit area . 75.6Water tightness . 85.7Resistance to impact . 85.8Durability . 85.9Compatibility with bitumen . 85.10Resistance to tearing (nail shank) . 85.11Joint strength . 85.12Water vapour transmission properties . 95.13Resistance to static loading . 95.14Tensile properties . 95.15Resistance to deformation under load . 95.16Reaction to fire . 95.17Dangerous substances . 96Evaluation of conformity . 106.1General . 106.2Type testing . 106.3Factory production control (FPC) . 107Product data sheet and designation . 138Marking, labelling and packaging . 13Annex A (informative)
Product designation, typical materials and structure of sheets . 14Annex B (normative)
Method of measuring the resistance of ventilating and draining damp-proof sheets to deformation under load . 15Annex C (informative)
Example of product data sheet . 19SIST EN 13967:2012



EN 13967:2012 (E) 3 Annex ZA (informative)
Clauses of this European Standard addressing essential requirements or other provisions of EU Directives . 21Bibliography . 31 SIST EN 13967:2012



EN 13967:2012 (E) 4 Foreword This document (EN 13967:2012) has been prepared by Technical Committee CEN/TC 254 “Flexible sheets for waterproofing”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2012, and conflicting national standards shall be withdrawn at the latest by October 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 13967:2004. The main technical changes are:
 For durability against chemicals, EN 1847:2009 of TC 254 is used instead of special Annex C.
 The minimum tolerance for the water vapour transmission is fixed.
 The rules for mounting and fixing for reaction of fire testing are improved and the variation of products where results apply are fixed. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This European Standard is a general product standard for flexible sheets of plastics intended for damp proof sheets, including plastics basement tanking sheets, for use in buildings. This standard is one of a series of product standards for factory made flexible sheets for use in buildings. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
SIST EN 13967:2012



EN 13967:2012 (E) 5 1 Scope This document specifies definitions and characteristics of flexible plastic and rubber sheets which are intended to be used as damp proofing for buildings, including basement tanking. It specifies the requirements and test methods, and provides for the evaluation of conformity of the products with the requirements of this standard. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1296, Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roofing — Method of artificial ageing by long term exposure to elevated temperature EN 1548, Flexible sheets for waterproofing — Plastic and rubber sheets for roof waterproofing — Method for exposure to bitumen EN 1847:2009, Flexible sheets for waterproofing —Plastic and rubber sheets for roof waterproofing — Methods for exposure to liquid chemicals, including water EN 1848-2, Flexible sheets for waterproofing — Determination of length, width, straightness and flatness — Part 2: Plastic and rubber sheets for roof waterproofing EN 1849-2, Flexible sheets for waterproofing — Determination of thickness and mass per unit area — Part 2: Plastic and rubber sheets EN 1850-2, Flexible sheets for waterproofing — Determination of visible defects — Part 2: Plastic and rubber sheets for roof waterproofing EN 1928:2000, Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roof waterproofing — Determination of watertightness EN 1931, Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roof waterproofing — Determination of water vapour transmission properties EN 12310-1, Flexible sheets for waterproofing — Part 1: Bitumen sheets for waterproofing — Determination of resistance to tearing (nail shank) EN 12311-2, Flexible sheets for waterproofing — Determination of tensile properties — Part 2: Plastic and rubber sheets for roof waterproofing EN 12317-2, Flexible sheets for waterproofing — Determination of shear resistance of joints — Part 2: Plastic and rubber sheets for roof waterproofing EN 12691, Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roof waterproofing — Determination of resistance to impact EN 12730:2001, Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roof waterproofing — Determination of resistance to static loading EN 13416:2001, Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roof waterproofing — Rules for sampling EN 13501-1:2007+A1:2009, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests SIST EN 13967:2012



EN 13967:2012 (E) 6 EN 13859-1:2010, Flexible sheets for waterproofing — Definitions and characteristics of underlays — Part 1: Underlays for discontinuous roofing EN ISO 11925-2, Reaction to fire tests — Ignitability of products subjected to direct impingement of flame — Part 2: Single-flame source test (ISO 11925-2) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 13416:2001 and the following apply. 3.1 sheet for damp proofing plastic or rubber sheet used on or under floors/ground slabs or in walls to prevent liquid water not under hydrostatic pressure passing from the ground into the internal environment 3.2 ventilating or draining damp proof sheet sheet conforming to the definition in 3.1 and with the ability to provide a continuous void or structure to allow free movement of water vapour or liquid water between the sheet and any further construction 3.3 tanking sheet sheet conforming to the definition in 3.1 used in wall construction or on or under floors or ground slabs to prevent liquid water under hydrostatic pressure passing from the ground into the internal environment or from one section of the structure to another 3.4 manufacturer's limiting value MLV value stated by the manufacturer to be met during testing
Note 1 to entry: The manufacturer's limiting value can be a minimum value or a maximum value, according to statements made under product characteristics of this standard. 3.5 manufacturer's declared value MDV value declared by the manufacturer accompanied by a declared tolerance 3.6 plastic sheet factory-made flexible sheet made from a plastic polymeric material and which may include composites of other materials 3.7 rubber sheet factory-made flexible sheet made from an elastomeric polymeric material and which may include composites of other materials 3.8 sampling procedure used to select or constitute a sample 3.9 sample sheet from which a test piece is taken SIST EN 13967:2012



EN 13967:2012 (E) 7 3.10 test piece part of the sample from which test specimens are taken 3.11 test specimen piece of precise dimensions taken from the test piece 3.12 batch amount of product continuously manufactured to the same specification
4 Product designation The types of damp proof sheets covered by this document are designated as follows: TYPE A damp proof sheet; TYPE V damp proof ventilating or draining sheet; TYPE T tanking sheet. 5 Product characteristics 5.1 General 5.1.1 Where a tolerance is specified by this document, it does not have to be declared by the manufacturer. 5.1.2 When tested for purposes other than initial type testing or factory production control, the tests to determine product characteristics indicated in this document shall be started within 1 month of delivery from the manufacturer. 5.2 Deviation from test sample dimensions Where the contours of the product make it impossible to obtain a test sample of the required dimensions, or otherwise render the test impracticable, testing may be carried out either on samples of different dimensions, or if still impracticable, on the equivalent flat sheet of the same thickness as the finished product. Any such deviations from the test method shall be recorded on the test report and the product data sheet. 5.3 Visible defects The product shall be free of visible defects as determined in accordance with EN 1850-2. 5.4 Dimensions and tolerances The length, width and straightness shall be determined in accordance with EN 1848-2. The length and width shall lie within the declared tolerance of the manufacturer's declared value (MDV). The maximum deviation from straightness shall not exceed 75 mm per 10 m length or shall be in the same proportion for other lengths (e.g. 37,5 mm per 5 m length). 5.5 Thickness and mass per unit area The thickness and mass per unit area shall be determined in accordance with EN 1849-2. SIST EN 13967:2012



EN 13967:2012 (E) 8 Where a product is specified by mass per unit area, the mass shall lie within the declared tolerance of the manufacturer's declared value. Where the dimensions of any profile are comparable to the area to be measured, a larger sample area shall be used and the deviation from the test method noted. Where a product is specified by thickness, the thickness shall lie within the declared tolerance of the manufacturer's declared value. No single measurement shall lie outside the declared tolerance of the manufacturer's declared value. 5.6 Water tightness The product shall be watertight as determined by Method A or B of EN 1928:2000 with a pressure of 2 kPa for Types A and V damp proof sheets and a pressure of 60 kPa for Type T damp proof sheets. 5.7 Resistance to impact Where required, the resistance to impact shall be determined in accordance with EN 12691 and the result shall be greater than or equal to the manufacturer's limiting value. 5.8
Durability 5.8.1 Against ageing/degradation In order to verify the artificial ageing behaviour of the product, watertightness shall be determined after exposure in accordance with EN 1296 for a period of 12 weeks. The watertightness shall be determined in accordance with EN 1928:2000 Method A or B. Type A and V damp proof sheets shall be tested at a pressure of 2 kPa and Type T tanking sheets at a pressure of 60 kPa, and shall give a pass result. 5.8.2 Against chemicals In order to verify the durability of the products, the sheet shall be tested before and after exposure to chemicals in accordance with EN 1847. The sheet shall be watertight as determined in accordance EN 1928:2000 Method A or B, with a pressure of 2 kPa for Types A and V damp proof sheets and a pressure of 60 kPa for Type T damp proof sheets, both before and after long-term exposure to alkali, in accordance with EN 1847:2009 test liquid 2 (milk of lime), 28 d, 23 °C. 5.9 Compatibility with bitumen Where required, the product shall be exposed to bitumen for 28 days at 70 °C using the method given in EN 1548, but with a sample size large enough to provide a 200 mm diameter circular sample after exposure. It shall be watertight when subsequently tested in accordance with Method A of EN 1928:2000. Type A and V damp proof sheets shall be tested at a pressure of 2 kPa and Type T tanking sheets at a pressure of 60 kPa. 5.10 Resistance to tearing (nail shank) For unreinforced sheets, the tear resistance (nail shank) shall be determined in accordance with EN 12310-1 and shall be greater than or equal to the manufacturer's limiting value. For reinforced sheets the tear resistance (nail shank) shall be determined in accordance with Annex B of EN 13859-1:2010 and shall be greater than or equal to the manufacturer's limiting value. 5.11 Joint strength Where required, the joint strength shall be determined in accordance with EN 12317-2 and shall be greater than or equal to the manufacturer's limiting value. SIST EN 13967:2012



EN 13967:2012 (E) 9 5.12 Water vapour transmission properties Where required, the moisture resistance factor µ of plastic and rubber sheets shall be determined in accordance with EN 1931 and the result shall lie within the declared tolerance of the MDV. The tolerance of the MDV shall lie in ± 30 %. 5.13 Resistance to static loading The resistance to static loading shall be determined in accordance with Method B of EN 12730:2001 and shall be greater than or equal to the manufacturer's limiting value. 5.14 Tensile properties The tensile properties of unreinforced sheets shall be determined in accordance with EN 12311-2 and shall be greater than or equal to the manufacturer's limiting value for the longitudinal and transverse directions of the sheet. The tensile properties of reinforced sheets shall be determined in accordance with Annex A of
EN 13859-1:2010 and shall be greater than or equal to the manufacturer's limiting value for the longitudinal and transverse directions of the sheet. 5.15 Resistance to deformation under load The resistance of ventilating or draining damp proof sheets to deformation under load shall be determined in accordance with Annex B and the results shall be less than or equal to the manufacturer's limiting value of deformation at the defined load and the defined time. 5.16 Reaction to fire Where required, the product shall be tested and classified in accordance with EN 13501-1:2007+A1:2009, Table 1. According to EN ISO 11925-2, the test is required to be undertaken on the exposed surface of the delivered flexible sheet membrane (surface exposure), free hanging without any substrate, in one direction only. The reinforcement shall be stated by the manufacturer as “organic” or “inorganic”. a) Test results from EN ISO 11925-2 for a given product shall apply to all colors (including black and white). b) Test results from EN ISO 11925-2 for a given product without an inner layer (homogenous) shall apply to a comparable product with an additional organic inner layer (lower than 150g/m2) or any additional inorganic layer. c) Test results from EN ISO 11925-2 for a product with a thickness of above 1 mm shall apply to any comparable product with a higher thickness up to a limit of 3 mm respectively d) Test results from EN ISO 11925-2 for a given product with a backing shall apply to a comparable product with a backing of the same type of lower mass per unit area or no backing. NOTE Whether the Euroclasses Classification system at Classes D and above requires investigation to determine its appropriateness to the products covered by this document is currently under consideration. (In particular it is thought that the SBI test may be inappropriate for products covered by the standard.) Pending results of such an investigation and discussions in the Fire Experts Group, products covered by this document are tested to EN ISO 11925-2. If and when a new fire test scenario and test method are developed for the products, this document will be amended to refer to them. 5.17 Dangerous substances NOTE For products placed on the market within the European Economic Area, see ZA.1. SIST EN 13967:2012



EN 13967:2012 (E) 10 Outside the EEA, products shall conform to any applicable provisions related to dangerous substances valid in the place of use. The manufacturer shall disclose on the product wrapper and in the health and safety data sheets the use of any additive or constituent considered hazardous. 6 Evaluation of conformity 6.1 General The compliance of a plastic or rubber damp proofing sheet with the requirements of this document and with the stated values (including classes) shall be demonstrated by:  initial type testing;  factory production control by the manufacturer, including product assessment. For the purposes of testing, products may be grouped into families, where the selected property is considered common to all products within that family. 6.2 Type testing 6.2.1 General Initial type testing shall be performed to show conformity with this document. Tests previously performed in accordance with the provisions of this standard (same product, same characteristic(s), test method, sampling procedure, system of attestation of conformity, etc.) may be taken into account. In addition, initial type testing shall be performed at the beginning of the production of a new product type (unless a member of the same family) or at the beginning of a new method of production (where this may affect the stated properties). All characteristics in Clause 5 shall be subject to initial type testing, where required. Whenever a change occurs in the product design, the raw material, supplier of the components or the production process (subject to the definition of a family) which would change significantly one or more of the characteristics, the type tests shall be repeated for the appropriate characteristic(s). 6.2.2 Sampling Samples shall be taken according to EN 13416. The minimum number of tests to show compliance for initial and further type testing shall be one for all characteristics. 6.3 Factory production control (FPC) 6.3.1 General The manufacturer shall establish, document and maintain an FPC system to ensure that the products placed on the market conform to the stated performance characteristics. The FPC system shall consist of procedures, regular inspections and tests and/or assessments and the use of the results to control raw and other incoming materials or components, equipment, the production process and the product. If a manufacturer claims compliance with FPC requirements by operating an EN ISO 9001 system,
EN ISO 9001 shall be applied in full and shall be made specific to the requirements of this document. The results of inspections, tests or assessments requiring action shall be recorded, as shall any action taken. The action to be taken when control values or criteria are not met shall be recorded. SIST EN 13967:2012



EN 13967:2012 (E) 11 6.3.2 Frequency of testing The characteristics to be controlled within the framework of FPC are those for which the manufacturer claims a performance. Control of the product is required, either by direct testing or by indirect control. The frequency of testing shall be given in the manufacturer's FPC system. SIST EN 13967:2012



EN 13967:2012 (E) 12 Table 1 — Compliance criteria for initial type testing Property (where required) Product Type Parameter Test method Sub-clause in this document Compliance criteria (where required) A V T Water tightness to liquid water
*
*
* Watertight At 2 kPa At 60 kPa EN 1928
5.6 Pass Resistance to static loading * * * MLV EN 12730 5.13 ≥ MLV Tensile properties - unreinforced sheets - reinforced sheets
* *
* *
* *
MLV MLV
EN 12311-2 EN 13859-1
5.14 5.14
≥ MLV Durability of watertightness against ageing
*
*
* Watertight At 2 kPa At 60 kPa EN 1296 Test afterwards to EN 1928 5.8.1 Pass Durability of watertightness against chemicals
*
*
* Watertight At 2 kPa At 60 kPa EN 1847 Test afterwards to EN 1928 5.8.2 Pass Resistance to impact * * * MLV EN 12691 5.7 ≥ MLV Resistance to tear (Nail Shank) - unreinforced sheets - reinforced sheets
* *
* *
* *
MLV MLV
EN 12310-1 EN 13859-1
5.10 5.10
≥ MLV Reaction to fire * * * Euroclass EN 13501-1 (see Note in 5.16) 5.16 Classification Bitumen compatibility
*
*
* Watertight At 2 kPa At 60 kPa EN 1548 and EN 1928 5.9 Pass Joint strength * * * MLV EN 12317-2 5.11 ≥ MLV Water vapour transmission * * * MDV EN 1931 5.12 Within declared tolerance of MDV Resistance to deformation under load
*
MLV Annex B 5.15 ≤ MLV Length * * * MDV EN 1848-2 5.4 Within declared tolerance of MDV Width * * * MDV EN 1848-2 5.4 Within declared tolerance of MDV Thickness * * * MDV EN 1849-2 5.5 Within declared tolerance of MDV
SIST EN 13967:2012



EN 13967:2012 (E) 13 Table 1 (continued)
Property (where required) Product Type Parameter Test method Sub-clause in this document Compliance criteria (where required) A V TMass * * * MDV EN 1849-2 5.5 Within declared tolerance of MDV Straightness * * * Less than or equal to 75 mm/10 m EN 1848-2 5.4 Pass Dangerous substances * * * As relevant As relevant 5.17 As relevant Visible defects * * * Visible defects EN 1850-2 5.3 No visible defects
7 Product data sheet and designation The characteristics of the product, determined in accordance with the test methods specified in this standard, shall be listed in a technical data sheet, an example of which is shown in Annex C. The technical data sheet shall give at least the following information: a) product trade name and manufacturer's name; b) origin/source of manufacture or traceable code; c) method of application; d) results from the tests in Table 1, as appropriate for the intended end use; e) certification mark, if any; f) consumer information, e.g. restrictions concerning use and storage and safety precautions during installation and disposal; g) description of the product (e.g. type and number of carriers, type of coating, mass or thickness, type of surfacing). 8 Marking, labelling and packaging The following information shall be indicated on each roll or at least on each consignment: a) production date or identification number; b) product trade name; c) length and width; d) thickness or mass; e) labelling according to national regulations related to dangerous substances and/or health and safety; f) type of product (Type A, Type V or Type T). NOTE Where ZA.3 covers the same information as requir
...