Lamp controlgear - Part 1: General and safety requirements

This part of IEC 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This standard also covers lamp controlgear for lamps which are not yet standardized. Tests dealt with in this standard are type tests. Requirements for testing individual lamp controlgear during production are not included. Requirements for semi-luminaires are given in IEC 60598-1 (see definition 1.2.60). In addition to the requirements given in this Part 1 of IEC 61347, Annex B sets out general and safety requirements applicable to thermally protected lamp controlgear. Annex C sets out additional general and safety requirements as they apply to electronic lamp controlgear with means of protection against overheating. Additional requirements for built-in ballasts with double or reinforced insulation are given in Annex I.

Geräte für Lampen - Teil 1: Allgemeine und Sicherheitsanforderungen

Appareillages de lampes - Partie 1: Exigences générales et exigences de sécurité

Stikalne naprave za sijalke - 1. del: Splošne in varnostne zahteve

Ta del IEC 61347 določa splošne in varnostne zahteve za stikalne naprave, primerne za uporabo sijalk v enosmernem toku napajanja do 250 V in/ali izmeničnem toku napajanja 1000 V pri 50 Hz ali 60 Hz. Ta standard prav tako zajema stikalne naprave za sijalke, ki še niso standardizirane. Preskusi, obravnavani v tem standardu, so tipski preskusi. Zahteve za preskušanje posameznih stikalnih naprav za sijalke med proizvodnjo niso vključene. Zahteve za polsijalke so podane v IEC 60598-1 (glej definicijo v točki 1.2.60). Poleg zahtev, podanih v tem delu 1 IEC 61347, dodatek B postavlja splošne in varnostne zahteve, ki veljajo za toplotno zaščitene stikalne naprave za sijalke. Dodatek C postavlja dodatne splošne in varnostne zahteve, kot veljajo za elektronska nadzorna stikala za sijalke s sredstvi zaščite proti pregretju. Dodatne zahteve za vgrajene predstikalne naprave z dvojno ali ojačano izolacijo so podane v dodatku I.

General Information

Status
Withdrawn
Publication Date
05-Jun-2013
Withdrawal Date
15-Apr-2018
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
16-Apr-2018
Due Date
09-May-2018
Completion Date
16-Apr-2018

Relations

Buy Standard

Amendment
EN 61347-1:2008/A2:2013
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61347-1:2008/A2:2013
01-julij-2013
Stikalne naprave za sijalke - 1. del: Splošne in varnostne zahteve
Lamp controlgear - Part 1: General and safety requirements
Geräte für Lampen - Teil 1: Allgemeine und Sicherheitsanforderungen
Appareillages de lampes - Partie 1: Exigences générales et exigences de sécurité
Ta slovenski standard je istoveten z: EN 61347-1:2008/A2:2013
ICS:
29.130.01 Stikalne in krmilne naprave Switchgear and controlgear
na splošno in general
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
SIST EN 61347-1:2008/A2:2013 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61347-1:2008/A2:2013

---------------------- Page: 2 ----------------------

SIST EN 61347-1:2008/A2:2013

EUROPEAN STANDARD
EN 61347-1/A2

NORME EUROPÉENNE
January 2013
EUROPÄISCHE NORM

ICS 29.140.99


English version


Lamp controlgear -
Part 1: General and safety requirements
(IEC 61347-1:2007/A2:2012)


Appareillages de lampes -  Geräte für Lampen -
Partie 1: Exigences générales Teil 1: Allgemeine und
et exigences de sécurité Sicherheitsanforderungen
(CEI 61347-1:2007/A2:2012) (IEC 61347-1:2007/A2:2012)





This amendment A2 modifies the European Standard EN 61347-1:2008; it was approved by CENELEC on 2013-
01-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate
the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61347-1:2008/A2:2013 E

---------------------- Page: 3 ----------------------

SIST EN 61347-1:2008/A2:2013
EN 61347-1:2008/A2:2013 - 2 -
Foreword
The text of document 34C/1023/FDIS, future amendment 2 to edition 2 of IEC 61347-1, prepared by
SC 34C "Auxiliaries for lamps" of IEC/TC 34 "Lamps and related equipment" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 61347-1:2008/A2:2013.

The following dates are fixed:
(dop) 2013-10-01
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2016-01-01
standards conflicting with the
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.

This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment
Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC).

Endorsement notice
The text of the International Standard IEC 61347-1:2007/A2:2012 was approved by CENELEC as a
European Standard without any modification.
In the Bibliography of EN 61347-1:2008, the following notes have to be deleted for the standards
indicated:

IEC 60216-1:2001 NOTE Harmonised as EN 60216-1:2001 (not modified).
IEC 60664-1:1992 + A1:2000 + A2:2002 NOTE Harmonised as EN 60664-1:2003 (not modified).
IEC 60664-4:2005 NOTE Harmonised as EN 60664-4:2006 (not modified).
IEC 60664-5:2003 NOTE Harmonised as EN 60664-5:2003 (not modified).

In the Bibliography of EN 61347-1:2008, replace the existing references by the following new
references:

IEC 61347-2-1 NOTE Harmonised as EN 61347-2-1.
IEC 61347-2-2:2011 NOTE Harmonised as EN 61347-2-2:2012 (not modified)

---------------------- Page: 4 ----------------------

SIST EN 61347-1:2008/A2:2013
- 3 - EN 61347-1:2008/A2:2013
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

Addition and replacement in Annex ZA of EN 61347-1:2008:

Publication Year Title EN/HD Year
Add to Annex ZA of EN 61347-1:2008 the following new references:
IEC 60065 (mod) 2001 Audio, video and similar electronic EN 60065 2002
+ corr. August 2002 apparatus - Safety requirements + corr. August 2007
+ A11 2008
+ A12 2011


1)
IEC 60085 1984 Thermal evaluation and classification HD 566 S1 1990
of electrical insulation


IEC 60216 Series Electrical insulating materials - EN 60216 Series
Thermal endurance properties


IEC 60598-2 Series Luminaires - EN 60598-2 Series
Part 2: Particular requirements


IEC 60664-1 2007 Insulation coordination for equipment EN 60664-1 2007
within low-voltage systems -
Part 1: Principles, requirements and tests


IEC 60884-2-4 - Plugs and socket-outlets for household - -
and similar purposes -
Part 2-4: Particular requirements for plugs
and socket-outlets for SELV


IEC 60906-3 - IEC System of plugs and socket-outlets - -
for household and similar purposes -
Part 3: SELV plugs and socket-outlets, 16 A
6V, 12 V, 24 V, 48 V, a.c. and d.c.


IEC 60950-1 - Information technology equipment - Safety - EN 60950-1 -
Part 1: General requirements


IEC 61558-1 2005 Safety of power transformers, power EN 61558-1 2005
+ corr. March 2010 supplies, reactors and similar products - + corr. August 2006
+ corr. March 2008 Part 1: General requirements and tests
+ corr. April 2011


IEC 61558-2-6 2009 Safety of transformers, reactors, power EN 61558-2-6 2009
supply units and similar products for supply
voltages up to 1 100 V -
Part 2-6: Particular requirements and tests
for safety isolating transformers and power
supply units incorporating safety isolating
transformers



1)
HD 566 S1 is superseded by EN 60085:2004, which is based on IEC 60085:2004.

---------------------- Page: 5 ----------------------

SIST EN 61347-1:2008/A2:2013
EN 61347-1:2008/A2:2013 - 4 -
Publication Year Title EN/HD Year
IEC 61558-2-16 2009 Safety of transformers, reactors, power EN 61558-2-16 2009
supply units and similar products
for voltages up to 1 100 V -
Part 2-16: Particular requirements and tests
for switch mode power supply units and
transformers for switch mode power supply
units

In Annex ZA of EN 61347-1:2008 replace the references to IEC 60317-0-1:1997 and
IEC 60598-1:2003 by the following:
IEC 60317-0-1 2008 Specifications for particular types EN 60317-0-1 2008
of winding wires -
Part 0-1: General requirements - Enamelled
round copper wire


IEC 60598-1 (mod) 2008 Luminaires - EN 60598-1 2008
+ corr. October 2011 Part 1: General requirements and tests + A11 2009
+ corr. December 2011

---------------------- Page: 6 ----------------------

SIST EN 61347-1:2008/A2:2013



IEC 61347-1

®


Edition 2.0 2012-11




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE




AMENDMENT 2

AMENDEMENT 2





Lamp controlgear –

Part 1: General and safety requirements




Appareillages de lampes –

Partie 1: Exigences générales et exigences de sécurité
















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX V


ICS 29.140.99 ISBN 978-2-83220-477-1



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 61347-1:2008/A2:2013
– 2 – 61347-1 Amend.2 © IEC:2012
FOREWORD
This amendment has been prepared by subcommittee 34C: Auxiliaries for lamps, of IEC
technical committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34C/1023/FDIS 34C/1029/RVD

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________

Add, after the Foreword, the following new text:
Introduction
Work is currently underway to modify creepage distances and clearances requirements
regarding:
• working voltages with operating frequencies up to 30 kHz and with higher operating
frequencies then 30 kHz;
• impulse and resonance ignition;
• basic, supplementary and reinforced insulation;
• insulation between circuits;
• coated or potted controlgear.
This information is expected to be incorporated into the future Edition 3 of IEC 61347-1.

1 Scope
Replace the fifth, sixth and seventh paragraphs by the following new paragraph:
Particular requirements for controlgears providing safety extra low voltage (from now on
SELV) are given in Annex L.

---------------------- Page: 8 ----------------------

SIST EN 61347-1:2008/A2:2013
61347-1 Amend.2 © IEC:2012 – 3 –
2 Normative references
Add the following new references:
IEC 60065:2001, Audio, video and similar electronic apparatus – Safety requirements
IEC 60085:1987, Electrical insulation – Thermal classification and designation
IEC 60216 (all parts), Electrical insulating materials – Properties of thermal endurance
IEC 60598-2 (all Parts 2), Luminaires – Part 2: Particular requirements.
IEC 60664-1:2007, Insulation coordination for equipment within low-voltage systems – Part 1:
Principles, requirements and tests
IEC 60884-2-4, Plugs and socket-outlets for household and similar purposes – Part 2-4:
Particular requirements for plugs and socket outlets for SELV
IEC 60906-3, IEC System of plugs and socket-outlets for household and similar purposes –
Part 3: SELV plugs and socket-outlets, 16 A 6 V, 12 V, 24 V, 48 V, a.c. and d.c.
IEC 60950-1, Information technology equipment – Safety – Part 1: General requirements
IEC 61558-1:2005, Safety of power transformers, power supplies, reactors and similar
products – Part 1: General requirements and tests
IEC 61558-2-6:2009, Safety of transformers, reactors, power supply units and similar products
for supply voltages up to 1 100 V – Part 2-6: Particular requirements and tests for safety
isolating transformers and power supply units incorporating safety isolating transformers
IEC 61558-2-16:2009, Safety of transformers, reactors, power supply units and similar
products for supply voltages up to 1 100 V – Part 2-16: Particular requirements and tests for
switch mode power supply units and transformers for switch mode power supply units
Replace the references to IEC 60317-0-1:1997 and IEC 60598-1:2003 by the following:
IEC 60317-0-1:2008, Specifications for particular types of windings wires – Part 0-1: General
requirements – Enamelled round copper wire
IEC 60598-1:2008, Luminaires – Part 1: General requirements and tests

3 Terms and definitions
3.23
functional earthing (ground)
Replace the existing Notes 1 and 2 of the existing definition by the following Note to entry:
Note 1 to entry: In some cases, functional earthing may be necessary to facilitate starting and/or to avoid radio
interference.

Add, after Definition 3.26, the following new definitions:

---------------------- Page: 9 ----------------------

SIST EN 61347-1:2008/A2:2013
– 4 – 61347-1 Amend.2 © IEC:2012
3.27
extra-low voltage
ELV
voltage which does not exceed 50 V a.c. or 120 V ripple free d.c. between conductors, or
between any conductor and earth (voltage band 1 of IEC 60449:1973)
Note 1 to entry: “Ripple free” is conventionally defined for sinusoidal ripple voltage as a ripple content of not more
than 10 % r.m.s. The maximum peak value does not exceed 140 V for a nominal 120 V ripple-free d.c. system.
3.28
safety extra low voltage
SELV
ELV in a circuit which is isolated from the mains supply by insulation not less than that
between the primary and secondary circuits of a safety isolating transformer according to
IEC 61558-2-6
Note 1 to entry: Maximum voltage lower than 50 V a.c. r.m.s. or 120 V ripple free d.c. may be specified in
particular requirements, especially when direct contact with current-carrying parts is allowed.
Note 2 to entry: The voltage limit should not be exceeded at any load between full loads and no-load when the
source is a safety isolation transformer.
Note 3 to entry: “Ripple free” is conventionally an r.m.s. ripple voltage not more than 10 % of the d.c. component:
the maximum peak value does not exceed 140 V for a nominal 120 V ripple free d.c. system and 70 V for a nominal
60 V ripple free system.
3.29
body
term used in this standard as a general term which includes all accessible metal parts, shafts,
handles, knobs, grips and the like, accessible metal fixing screws and metal foil applied on
accessible surfaces of insulating material and does not include non-accessible metal parts
3.30
impulse withstand category
DEPRECATED: overvoltage category
numeral defining a transient overvoltage condition
Note 1 to entry: Impulse withstand categories I, II, III and IV are used. For detailed information, see IEC 60664-1
and IEC 60598-1.
3.31
class I lamp controlgear
independent controlgear in which protection against electric shock does not rely on basic
insulation only, but which includes an additional safety precaution in such a way that means
are provided for the connection of accessible conductive parts to the protective (earthing)
conductor in the fixed wiring of the installation in such a way that accessible conductive parts
cannot become live in the event of a failure of the basic insulation
Note 1 to entry: Class I lamp independent controlgear may have parts with double or reinforced insulation.
Note 2 to entry: Class I lamp independent controlgear may have parts in which protection against shock relies on
operation at safety extra-low voltage (SELV)
3.32
class II lamp controlgear
independent controlgear in which protection against electric shock does not rely on basic
insulation only, but in which additional safety precautions such as double insulation or
reinforced insulation are provided, there being no provision for protective earthing or reliance
upon installation conditions
3.33
class III lamp controlgear
independent controlgear in which protection against electric shock relies on supply at safety
extra-low voltage (SELV) and in which voltages higher than those of SELV are not generated

---------------------- Page: 10 ----------------------

SIST EN 61347-1:2008/A2:2013
61347-1 Amend.2 © IEC:2012 – 5 –
3.34
protective impedance device
component or assembly of components the impedance and construction of which are such as
to ensure that steady state touch current and charge are limited to a non-hazardous level
3.35
maximum working voltage
U
out
maximum occurring working voltage (r.m.s.) between the output terminals or between the
output terminals and earth, during normal or abnormal operating condition
Note 1 to entry: Transients and ignition voltages have to be neglected.
3.36
basic insulation
insulation of parts which provide protection against electrical shock under fault-free conditions
3.37
double insulation
insulation of parts with two layers of insulation which provide protection against electrical
shock under single fault condition
3.38
reinforced insulation
Insulation of parts which provide a degree of protection as double insulation

4 General requirements
Add, after the second paragraph, the following new paragraph:
Requirements for insulation materials used for double or reinforced insulation of controlgear
are specified in Annex N of this standard.
Add, after the third paragraph, the following new paragraph:
Built-in electronic controlgear with double or reinforced insulation shall comply additionally
with the requirements of Annex O.
Add, at the end of Clause 4, the following new paragraph:
Controlgears providing SELV shall comply with the additional requirements given in Annex L.
This includes especially insulation resistance, electric strength, creepage distances and
clearances between the primary and secondary circuit.

5 General notes on tests
Add, at the end of Subclause 5.3, the following new paragraph:
If the tests of 14.3 or 15.5 of IEC 61558-1:2005 have to made, three additional samples are
needed. These samples are used only for the test of 14.3 or 15.5 of IEC 61558-1:2005,
respectively.

---------------------- Page: 11 ----------------------

SIST EN 61347-1:2008/A2:2013
– 6 – 61347-1 Amend.2 © IEC:2012
7.1 Items to be marked
Add, after the first paragraph of Subclause 7.1, but before the alphabetical list, the following
new paragraph:
For controlgear without an enclosure, and classified as built-in (e.g. open printed circuit board
assembly), only items a) and b) are to be considered mandatory for marking on the
controlgear. Other mandatory markings required by the IEC 61347-2 part shall be provided as
information to be given either on the controlgear or made available in the manufacturer’s
catalogue or similar.
Replace the existing point f) by the following new point f):
f) The earthing terminals (if any) shall be identified by the symbol or .

These symbols shall not be placed on screws or other easily removable parts.
If the lamp control gear is market with an earthing symbol, the manufacturer’s instruction
shall contain the information whether it is permitted to use the control gear also without
connection to earth.
NOTE For the use of symbols, see IEC 60417.

Add, at the end of Subclause 7.1, the following new items, table and text:
s) Symbol indicating the kind of controlgear providing SELV.
t) The earthing terminals of an independent controlgear used for the connection of lamp
compartments (if any) shall be marked with the symbol:

This symbol shall not be placed on screws or other easily removable parts. The symbol size of
the earthing terminals of an independent controlgear used for the connection of lamp
compartments shall be at least 5 mm (over all, including letters).
u) Declaration of the maximum working voltage U (r.m.s.) between
out
• output terminals, or
• any output terminal and earth (if applicable)
in steps as described in Table 5.
Table 5 – Working voltage and U steps
out
Working voltage < 50 V < 500 V > 500 V
U in steps of 1 V 10 V 50 V
out

The highest of the specified voltage values shall be marked on the controlgear as “Output
working voltage = …V” or “U-OUT = …V” or “U = …V”.
out
NOTE 5 Item u) is not applicable to terminals with SELV-circuits as defined in IEC 61558-1.

---------------------- Page: 12 ----------------------

SIST EN 61347-1:2008/A2:2013
61347-1 Amend.2 © IEC:2012 – 7 –
9 Provisions for protective earthing
Replace the existing title and content of Clause 9 by the following:
9 Earthing
9.1 Provisions for protective earthing (Symbol: IEC 60417-5019 (2006-08))
Earthing terminals shall comply with the requirements of Clause 8. The electrical connection/
clamping means shall be adequately locked against loosening, and it shall not be possible to
loosen the electrical connection/clamping means by hand without the use of a tool. For
screwless terminals, it shall not be possible to loosen the clamping means/electrical
connection unintentionally.
All parts of an earthing terminal shall be such as to minimize the danger of electrolytic
corrosion resulting from contact with the earth conductor or any other metal in contact with
them.
The screw and the other parts of the earthing terminal shall be made of brass or other metal
no less resistant to corrosion, or material with a non-rusting surface and at least one of the
contact surfaces shall be bare metal.
Compliance is checked according to 7.2.3 of IEC 60598-1:2008.
9.2 Provisions for functional earthing (Symbol: IEC 60417-5018 (2011-07))
Functional earthing terminals shall comply with the requirements of Clause 8 and 9.1.
The functional earthing contact (potential) of a lamp controlgear shall be insulated from the
live parts by double or reinforced insulation.
9.3 Lamp controlgear with conductors for protective earthing by tracks on printed
circuit boards
If a printed circuit board track is used for earthing internally, in the independent, built-in or
integral lamp controlgear, it shall withstand the following test.
A current from an a.c. source of 25 A is passed for 1 min between the earthing terminal or
earthing contact via the track on the printed circuit board and each of the accessible metal
parts in turn.
After the test and after cooling the controlgear to ambient temperature, the requirements of
7.2.3 of IEC 60598-1:2008 shall apply.
9.4 Earthing of built-in lamp controlgear
It is allowed to earth built-in lamp controlgear by means of fixing the controlgear to earthed
metal of the luminaire.
For compliance, see 7.2 of IEC 60598-1:2008.
If a lamp controlgear has an earthing terminal, this terminal shall only be used for earthing the
built-in lamp controlgear.
Earthing of the luminaire or other equipment via the built-in lamp controlgear is not allowed.

---------------------- Page: 13 ----------------------

SIST EN 61347-1:2008/A2:2013
– 8 – 61347-1 Amend.2 © IEC:2012
9.5 Earthing via independent controlgear
9.5.1 Earth connection to other equipment
Independent lamp controlgear may have earthing terminals that allow the onward earth
connection to other equipment in the installation. For looping or through connection, the
2
conductor shall have a minimum cross-section of 1,5 mm and be of copper, or an equivalent
conductive material shall be used.
Protective earthing wires within the luminaire shall be in line with 5.3.1.1 and Clause 7 of
2
IEC 60598-1:2008. For looping-through, a minimum cross section of 1,5 mm is required.
Compliance is checked by inspection and measurement.
9.5.2 Earthing of the lamp compartments powered via the independent lamp
controlgear
Independent lamp controlgear may have earthing terminals that allow the earthing of the lamp
compartment, which are powered by this controlgear. In this case, the earth path between the
input and output earth terminals of the controlgear shall withstand the following test.
A current from an a.c. source of 25 A is passed for 1 min between the earthing terminal or
earthing contact (via the track on the printed circuit board, if used for protective earth) and
each of the accessible metal parts in turn.
After the test and after cooling the control gear at ambient temperature, a current of at least
10 A, derived from the source with a no-load voltage not exceeding 12 V, shall be passed
between the earthing terminal or earthing contact and each of the accessible metal parts in
turn. The voltage drop between the earthing terminal or earthing contact and the accessible
metal part shall be measured and the resistance shall be calculated from the current and the
voltage drop. In no case shall the calculated resistance value exceed 0,5 Ω.
The output earthing terminals to the lamp compartment shall be marked as described in 7.1 t).

10 Protection against accidental contact with live parts
Add, after Subclause 10.2, the following new subclauses:
10.3 For controlgears providing SELV, the accessible conductive parts shall be electrically
separated from live parts by at least double or reinforced insulation. There shall be no
connection between the output circuit and the body or the protective earthing circuit, if any.
Moreover, the construction shall be such that there is no possibility of any connection
between these circuits, either directly or indirectly, through other conductive parts, except by
deliberate action (see 10.4).
SELV output circuits shall be electrically separated from earth by at least basic insulation.
The expression “circuits” also covers windings of internal transformers (HF and others) of the
controlgear.
In controlgears providing ELV conductive parts are regarded as live parts and shall be
insulated accordingly.
Compliance is checked by inspection, relevant insulation tests and measurements. See also
Annex L.

---------------------- Page: 14 ----------------------

SIST EN 61347-1:2008/A2:2013
61347-1 Amend.2 © IEC:2012 – 9 –
10.4 Controlgears providing SELV may have accessible conductive parts in the SELV circuit;
if: the rated output voltage under load does not exceed 25 V r.m.s. or 60 V d.c. ripple free d.c.
where the voltage exceeds 25 V r.m.s. or 60 V ripple free d.c., the touch current does not
exceed:
– for a.c.: 0,7 mA (peak);
– for d.c.: 2,0 mA;
– the no-load output does not exceed 35 V peak or 60 V ripple free d.c.
NOTE The limits given are based on IEC 60364-4-41.
Compliance is checked by measuring the output voltage when steady conditions are
established, the controlgear being connected to rated supply voltage and rated frequency. For
the test under load the controlgear is loaded with a resistance which would give rated output
(current or wattage respectively) at rated output voltage. For controlgears with more than one
supply voltage, the requirements are applicable for each of the rated supply voltages.
The touch current is checked by measurement in accordance with Annex G from IEC 60598-1.
For controlgears providing SELV with rated output voltages or currents exceeding the values
given above at least one of the conductive parts in the SELV circuit shall be insulated by
insulation capable of withstanding a test voltage of 500 V r.m.s. for 1 min.
Accessible conductive parts separated by double or reinforced insulation, e.g. live parts and
the body or primary and secondary circuits, may be bridged (conductive bridged) by resistors
or Y2 capacitors provided they consists of at least two separate components of the same
rated value (resistance or capacitance) and are rated for the total working voltage and whose
impedance is unlikely to change significantly during the individual lifetime of the controlgear.
In addition, accessible conductive parts separated by double or reinforced insulation from live
parts, as above, may be bridged by a single Y1 capacitor.
Y1 or Y2 capacitors shall comply with relevant requirements of IEC 60384-14 and if resistors
are used they shall comply with the requirements of test (a) in 14.1 of IEC 60065:2001.

11 Moisture resistance and insulation
Replace, after the third paragraph after the note, the rest of the text of Clause 11 by the
following:
Insulation resistance shall be not less than 2 MΩ for basic insulation and 4 MΩ for double or
reinforced insulation between live parts and the body. For insulation between primary and
secondary circuits, in controlgear providing SELV, other values apply (see Annex L).
Insulation shall be adequate
a) between live parts and outer metal parts, including fixing screws and metal foil in contact
with outer insulating parts;
b) between live parts and control terminals, where relevant.
In the case of lamp controlgear having an internal connection or component between one or
more output terminals and the earth terminal, such a connection shall be removed during
this test.
For the test the input and output terminals shall be bonded together. Controlgear, having
insulation cover or envelope is wrapped with metal foil.

---------------------- Page: 15 ----------------------

SIST EN 61347-1:2008/A2:2013
– 10 – 61347-1 Amend.2 © IEC:2012
12 Electric strength
Replace the existing Table 1 by the following new Table 1:
Table 1 – Electric strength test voltage
Test voltage
Working voltage U
V
Basic insulation for voltages of SELV 500
Up to and including 50 V 500
Basic insulation 2 U + 1 000
Above 50 V up to and including 1 000 V Supplementary insulation 2 U + 1 000
Double or reinforced insulation 4 U + 2 000
Where both reinforced insulation and double insulation are used, care shall be taken that the voltage applied to
the reinforced insulation does not overstress the basic insulation or the supplementary insulation.
When testing the controlgear the input should be tested with a test voltage which corresponds with the supply
voltage and the output related part should be tested with a test voltage which corresponds with U .
out

Add the fol
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.