Pipes and fittings of longitudinally welded stainless steel pipes with spigot and socket for waste water systems - Part 4: Components for vacuum drainage systems and for drainage systems on ships

This European Standard specifies requirements, dimensions and tolerances for pipes and fittings of longitudinally welded, stainless steel pipe with spigot and socket used for vacuum drainage systems inside and outside buildings and for gravity and vacuum drainage systems on ships and floating maritime structures)
-   above freeboard deck as long as the heeling is taken into account in the event of damage when installed above freeboard deck on passenger ships;
-   inside a watertight compartment below freeboard deck;
-   with direct connection to the outboard (not permitted below freeboard deck);
-   inside tanks as long as these are not filled with foreign media and are not cargo tanks.
On well-anchored maritime structures, this European Standard applies to pipes and fittings of longitudinally welded stainless steel pipe with spigot and socket used in drainage systems in the accommodation area.
NOTE   Pipes and fittings according to this European Standard may also be used in central vacuum cleaning installations, in vacuum suction lifting installations, in chip transporting installations and in other waste water and process pipes as long as the media to be discharged do not damage the components or the health and safety of the personnel.
For other pipes, this European Standard only applies if agreed with the relevant operators and following prior consultation with the manufacturer.
This European Standard contains a designation system for the different types of pipes and fittings for easy identification of each component.
This European Standard is only applicable in conjunction with EN 1124-1. It does not apply to the marking of products for which EN 1124-1/A1 is applicable.

Rohre und Formstücke aus längsnahtgeschweißtem nichtrostendem Stahlrohr mit Steckmuffe für Abwasserleitungen - Teil 4: Bauteile für Unterdruckentwässerungssysteme und Entwässerungssysteme auf Schiffen

Diese Europäische Norm legt Anforderungen, Maße und Grenzabmaße für Rohre und Formstücke aus längsnahtgeschweißtem, nichtrostendem Stahlrohr mit Steckmuffe fest, die für Unterdruckentwässerungssysteme innerhalb und außerhalb von Gebäuden sowie für Schwerkraft- und Unterdruckentwässerungssysteme auf Schiffen und auf schwimmenden Seebauwerken )
-   oberhalb Freiborddeck, sofern für Fahrgastschiffe bei Verlegung oberhalb Freiborddeck die Krängung im Beschädigungsfall berücksichtigt wird,
-   innerhalb einer wasserdichten Abteilung unterhalb Freiborddeck,
-   bei direkter Verbindung nach Außenbords (nicht zulässig unterhalb Freiborddeck),
-   innerhalb von Tanks, sofern diese nicht mit artfremden Medien gefüllt werden und keine Ladetanks sind,
verwendet werden.
Auf fertig gegründeten Seebauwerken gilt diese Europäische Norm für Rohre und Formstücke aus längsnahtgeschweißtem, nichtrostendem Stahlrohr mit Steckmuffe die in Entwässerungsanlagen im Wohnbereich verwendet werden.
ANMERKUNG   Rohre und Formstücke nach dieser Europäischen Norm können auch in Zentralstaubsauganlagen, in Vakuumsaugförderanlagen, in Spänetransportanlagen und in anderen Abwasser- und Prozessleitungen verwendet werden, sofern die abzuleitenden Medien die Bauteile nicht beschädigen oder die Gesundheit oder Sicherheit des Personals nicht gefährden.
Für andere Leitungen gilt diese Europäische Norm nur nach Vereinbarung mit den zuständigen Betriebsstellen und nach vorheriger Rücksprache mit dem Hersteller.
Diese Europäische Norm enthält zur einfachen Identifizierung jedes Bauteils ein System für die Bezeichnung der verschiedenen Arten von Rohren und Formstücken.
Diese Europäische Norm gilt nur in Verbindung mit EN 1124 1. Sie gilt nicht für die Kennzeichnung der Produkte. Hierfür gilt EN 1124 1/A1.

Tubes et raccords de tubes soudés longitudinalement en acier inoxydable, a manchon enfichable pour réseaux d'assainissement - Partie 4: Composants des réseaux d'évacuation sous vide et par gravité installés sur les navires

La présente Norme européenne spécifie les prescriptions, dimensions et tolérances relatives aux tubes et raccords a manchon enfichable en acier inoxydable, soudés longitudinalement, utilisés dans les réseaux d'évacuation sous vide a l'intérieur et a l'extérieur des bâtiments ainsi que dans les réseaux d'évacuation par gravité et sous vide installés sur les navires et les structures maritimes flottantes.
-   au-dessus du franc-bord si, en cas d'installation au-dessus du pont de franc-bord sur les paquebots, on tient compte de la gîte en cas de détérioration ;
-   a l'intérieur d'un compartiment étanche situé au-dessous du franc-bord ;
-   en cas de raccordement direct aux hors bords (interdit au-dessous du franc-bord) ;
-   a l'intérieur de cuves, si ces dernieres ne sont pas remplies de produits non adaptés et ne sont pas des citernes de chargement.
Pour les structures maritimes préfabriquées, la présente Norme européenne s'applique aux tubes et raccords soudés longitudinalement, en acier inoxydable a manchon enfichable, qui sont utilisés dans les réseaux d'évacuation des zones d'habitation.
NOTE   Les tubes et raccords conformes a la présente norme européenne peuvent également etre utilisés dans des installations de dépoussiérage centralisées, des transporteurs par aspiration sous vide, des installations de transport des copeaux et autres réseaux d'assainissement domestiques et industriels, a condition que les produits a  évacuer ne détériorent pas les composants et ne compromettent pas la santé ou la sécurité du personnel.
Pour d'autres canalisations, la présente Norme européenne ne s'applique qu'apres accord avec les services compétents et concertation préalable avec le fabricant.
Pour simplifier l'identification de chaque composant, la présente Norme européenne comporte un systeme de désignation des divers types de tubes et raccords.

Vzdolžno varjene nerjavne jeklene cevi in spojniki z obojko za sisteme za odpadno vodo – 4. del: Sestavni deli za podtlačne sisteme za odvodnjavanje in za sisteme za odvodnjavanje na ladjah

General Information

Status
Withdrawn
Publication Date
30-Nov-2005
Withdrawal Date
13-Nov-2013
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
13-Nov-2013
Due Date
06-Dec-2013
Completion Date
14-Nov-2013

Relations

Buy Standard

Standard
EN 1124-4:2005
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Rohre und Formstücke aus längsnahtgeschweißtem nichtrostendem Stahlrohr mit Steckmuffe für Abwasserleitungen - Teil 4: Bauteile für Unterdruckentwässerungssysteme und Entwässerungssysteme auf SchiffenTubes et raccords de tubes soudés longitudinalement en acier inoxydable, a manchon enfichable pour réseaux d'assainissement - Partie 4: Composants des réseaux d'évacuation sous vide et par gravité installés sur les naviresPipes and fittings of longitudinally welded stainless steel pipes with spigot and socket for waste water systems - Part 4: Components for vacuum drainage systems and for drainage systems on ships93.030Zunanji sistemi za odpadno vodoExternal sewage systems47.020.30Sistemi ceviPiping systems23.040.10Železne in jeklene ceviIron and steel pipesICS:Ta slovenski standard je istoveten z:EN 1124-4:2005SIST EN 1124-4:2005en01-december-2005SIST EN 1124-4:2005SLOVENSKI
STANDARD



SIST EN 1124-4:2005



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1124-4August 2005ICS 23.040.10; 23.040.40; 47.020.30 English VersionPipes and fittings of longitudinally welded stainless steel pipeswith spigot and socket for waste water systems - Part 4:Components for vacuum drainage systems and for drainagesystems on shipsTubes et raccords à manchon enfichable en acierinoxydable, soudés longitudinalement pour réseauxd'assainissement - Partie 4: Composants utilisés pour lessystèmes d'évacuation sous vide et gravitaires installés surles naviresRohre und Formstücke aus längsnahtgeschweißtemnichtrostendem Stahlrohr mit Steckmuffe fürAbwasserleitungen - Teil 4: Bauteile fürUnterdruckentwässerungssysteme undEntwässerungssysteme auf SchiffenThis European Standard was approved by CEN on 8 July 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2005 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 1124-4:2005: ESIST EN 1124-4:2005



EN 1124-4:2005 (E) 2 Contents Page Foreword.3 1 Scope.5 2 Normative references.5 3 Terms and definitions.6 4 Symbols and abbreviations.6 5 Pipes and fittings requirements.6 5.1 General.6 5.2 Operating pressure, operating temperature and tightness.7 6 Dimensions.8 6.1 General and tolerances.8 6.2 Pipes, fittings and seals used for system X according to EN 1124-3.8 6.2.1 Sockets.8 6.2.2 Pipes and fittings for deck drainage and gravity drainage systems (gravity systems).9 6.2.3 Components for vacuum systems.18 6.2.4 Other fittings.19 6.2.5 Seals for system X.19 6.3 Pipes, fittings and seals used for system S as specified in EN 1124-2.22 6.3.1 Sockets for gravity drainage systems (gravity systems).22 6.3.2 Pipes and fittings for deck drainage and gravity drainage systems (gravity systems).22 6.3.3 Components for vacuum systems.31 6.3.4 Other fittings.31 6.3.5 Seals for system S.31 7 Testing.31 8 Assessment of conformity (quality control).32 Bibliography.33
SIST EN 1124-4:2005



EN 1124-4:2005 (E) 3 Foreword This European Standard (EN 1124-4:2005) has been prepared by Technical Committee CEN/TC 165 “Waste water engineering”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2006, and conflicting national standards shall be withdrawn at the latest by February 2006. This European Standard on pipes and fittings of longitudinally welded stainless steel pipes with spigot and socket for waste water systems consists of the following Parts:
 Part 1: Requirements, testing, quality control  Part 2: System S – Dimensions  Part 3: System X – Dimensions  Part 4: Components for vacuum drainage systems and drainage systems on ships According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 1124-4:2005



EN 1124-4:2005 (E) 4 Introduction Pipes and fittings of longitudinally welded, stainless steel pipes with spigot and socket for waste water systems as specified in EN 1124-2 and –3 are used in gravity drainage systems in buildings. For vacuum drainage systems and drainage systems on ships, it was necessary to specify additional requirements and further dimensional specifications for components and joints used in these systems. Components specified in this European Standard are used for vacuum drainage systems and for drainage systems in shipbuilding
SIST EN 1124-4:2005



EN 1124-4:2005 (E) 5 1 Scope This European Standard specifies requirements, dimensions and tolerances for pipes and fittings of longitudinally welded, stainless steel pipe with spigot and socket used for vacuum drainage systems inside and outside buildings and for gravity and vacuum drainage systems on ships and floating maritime structures1)
 above freeboard deck as long as the heeling is taken into account in the event of damage when installed above freeboard deck on passenger ships;  inside a watertight compartment below freeboard deck;  with direct connection to the outboard (not permitted below freeboard deck);  inside tanks as long as these are not filled with foreign media and are not cargo tanks. On well-anchored maritime structures, this European Standard applies to pipes and fittings of longitudinally welded stainless steel pipe with spigot and socket used in drainage systems in the accommodation area.
NOTE Pipes and fittings according to this European Standard may also be used in central vacuum cleaning installations, in vacuum suction lifting installations, in chip transporting installations and in other waste water and process pipes as long as the media to be discharged do not damage the components or the health and safety of the personnel.
For other pipes, this European Standard only applies if agreed with the relevant operators and following prior consultation with the manufacturer.
This European Standard contains a designation system for the different types of pipes and fittings for easy identification of each component.
This European Standard is only applicable in conjunction with EN 1124-1. It does not apply to the marking of products for which EN 1124-1/A1 is applicable.
2 Normative references The following referenced documents are indispensable for the application of this European Standard.
For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any amendments) applies. EN 681-1, Elastomeric seals — Material requirements for pipe joint seals used in water and drainage applications — Part 1: Vulcanized rubber
EN 1124-1:1999, Pipes and fittings of longitudinally welded, stainless steel pipe with spigot and socket for waste water systems — Part 1: Requirements, testing, quality control
EN 1124-2, Pipes and fittings of longitudinally welded, stainless steel pipe with spigot and socket for waste water systems — Part 2: System S; dimensions
EN 1124-3, Pipes and fittings of longitudinally welded, stainless steel pipe with spigot and socket for waste water systems — Part 3: System X; dimensions
EN 10025 (all Parts), Hot rolled products of non-alloy structural steels
1) In shipbuilding, the terms "Gravity and vacuum system" are used for this.
SIST EN 1124-4:2005



EN 1124-4:2005 (E) 6
EN 10226-1, Pipe threads where pressure tight joints are made on the threads — Part 1: Designation, dimensions and tolerances
EN 12109, Vacuum drainage systems inside buildings
EN ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads — Part 1: Dimensions, tolerances and designation (ISO 228-1:2000)
EN ISO 15749-2, Ships and marine technology — Drainage systems on ships and marine structures —
Part 2: Sanitary drainage, drain piping for gravity system (ISO 15749-2:1994)
EN ISO 15749-3, Ships and marine technology — Drainage systems on ships and marine structures —
Part 3. Sanitary drainage, drain piping for vacuum system (ISO15749-3:2004)
3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 1124-1:1999 apply.
4 Symbols and abbreviations DN/ID nominal size with regard to the inside diameter
DN/OD nominal size with regard to the outside diameter
d
diameter
t
socket depth
s
wall thickness
l
effective length
s2
wall thickness of weld-in sleeve
m10
thread size
k
diameter of hole sequence
5 Pipes and fittings requirements 5.1 General Components covered by this European Standard shall meet the requirements of EN 1124-1.
They shall be suitable for use in drainage systems for the discharge of black water, gray water and waste water from process pipe systems.
For weld-in sleeves and flanges, weldable material, e.g. S235 JRG2 as specified in EN 10025 or the specifications of the classification societies valid at the place of use of the product shall be used
The suitability of these pipes and fittings for other media shall be agreed with the manufacturer.
SIST EN 1124-4:2005



EN 1124-4:2005 (E) 7 5.2 Operating pressure, operating temperature and tightness The components shall be dimensioned so that they are reliably tight under the operating conditions given in Table 1 and Table 2 with the indicated socket shape, outside diameter and type being used.
Table 1 — Type of socket joint according to operating data for pipe system X Socket joint Pipe system for Operating pressure Operating temperature Seala Type Socket shapeb Deck drainage
Gravity drainage (sanitary drain pipe in gravity system)
up to 0,5 bar M 1, M 5
inserted 1 A, 2 A, 3 A – 0,3 bar to
– 0,6 bar (corresponding to 0,7 bar to 0,4 bar absolute pressure) M 1 inserted and bonded 1 A, 2 A, 3 A M 5 inserted
1 A, 2 A, 3 A Vacuum drainage (sanitary drain pipe in vacuum system)
up to – 0,8 bar (corresponding to 0,2 bar absolute pressure) up to 90 °C in cyclical dutyc M 4 inserted
1 V or 3 V Vent line Following agreement with the relevant supervisory bodies and discussion with the manufacturer
M 1, M 6 inserted and bonded with shear protection 1 A, 2 A, 3 A a Requirements according to EN 1124-1. b Socket shapes A according to EN 1124-3; socket shape V according to 6.2.1. c For higher temperatures, the manufacturer shall be consulted.
Table 2 — Type of operating data for pipe system S Pipe system for Operating pressure Operating temperature DN/OD Deck drainage
Gravity drainage (sanitary drain pipe in gravity system) up to 0,5 bar 50 to 160
up to – 0,6 bar (corresponding to 0,4 bar absolute pressure) 110 to 160 Vacuum drainage (sanitary drain pipe in vacuum system) up to – 0,8 bar (corresponding to 0,2 bar absolute pressure) up to 90 °C in cyclical dutya 50 to 75 Vent line Following agreement with the relevant supervisory bodies and discussion with the manufacturer
50 to 160 a For higher temperatures, the manufacturer shall be consulted.
SIST EN 1124-4:2005



EN 1124-4:2005 (E) 8 6 Dimensions 6.1 General and tolerances The figures are simplified drawings. The dimensions given shall be followed.
Where no tolerances are given in this European Standard, the tolerances specified in EN 1124-2 and
EN 1124-3 shall be adhered to for system S and system X respectively.
6.2 Pipes, fittings and seals used for system X according to EN 1124-3 6.2.1 Sockets 6.2.1.1 Sockets for gravity drainage systems (gravity systems) For system X, the socket shapes and socket dimensions shall conform to type A in EN 1124-3. If the designation of the fittings does not specify the socket shape, they are of socket shape 1 A. Dimensions not specified shall be chosen accordingly.
6.2.1.2 Sockets for vacuum operation (vacuum system) For system X for vacuum operation, components according to EN 1124-3 with socket shape A in conjunction with seals of shape M 1 or M 5 or components according to this European Standard with socket shapes as shown in Figure 1 and dimensions in Table 3 shall be used. The socket shape shall be designated V instead of A for these components.
If the designation of the fittings does not contain the socket shapes, these shall be shape 1 A or 1 V. Dimensions not specified shall be chosen accordingly.
Socket shape 1 V
Socket shape 3 V
Vacuum socket
Long vacuum socket
Figure 1 — Socket shapes
SIST EN 1124-4:2005



EN 1124-4:2005 (E) 9 Table 3 — Socket dimensions Dimensions in millimetres Socket dimensions Nominal size DN/ID d1 a s b d2 d3 Tolerances for d1 to d3 t1 t2 Tolerances for t1 to t2 40 42 1,5 ± 0,15 45 48 ± 0,6 38 70 24−+ 50 53 1,5 ± 0,15 56 60 ± 0,6 41 90 24−+ 70 73 1,6 ± 0,16 76 81 ± 0,7 55 120 24−+ a Pipe ends slightly retracted. B The indications on wall thickness refer to special steel pipes (heavy series) according to EN 1124-3.
6.2.2 Pipes and fittings for deck drainage and gravity drainage systems (gravity systems) 6.2.2.1 General For gravity systems according to EN ISO 15749-2 and for deck drainage systems made of system X components, pipes and fittings with socket shape A and seals of shape M 1 or M 5 as indicated in Table 4 shall be used.
Table 4 — List of pipes, fittings and seals Designation Shape Subclause or EN number Pipes B 1 or B 2 EN 1124-3 Bend C 1 EN 1124-3 Bend with stilling section C 3 EN 1124-3 Branches D 1, D 11, D 21 EN 1124-3 Transition pipe F 2 EN 1124-3 Repair coupling F 4 EN 1124-3 Insertion coupling F 5 EN 1124-3 Connecting pieces with weld-in sleeve R 1 A, R 1 B, T 1, T 1 S 6.2.2.2 and 6.2.2.3 Connecting pieces for WC J 1, J 2, J 3, J 4 6.2.2.4 Transition pieces E 1, E 2 6.2.2.5 Threaded connectors L 1, L 3 6.2.2.6 Flange connecting pieces M 1, M 2 6.2.2.7 Other fittings - 6.2.4, EN 1124-3
SIST EN 1124-4:2005



EN 1124-4:2005 (E) 10 6.2.2.2 Short connecting pieces with weld-in sleeve For system X, short connecting pieces with a weld-in sleeve are shown in Figures 2 and 3.
Dimensions for short connecting pieces with a weld-in sleeve are given in Table 5.
straight, sleeve not flush – shape R 1 A
straight, sleeve flush – shape R 1 B
Dimensions in millimetres
Dimensions in millimetres
Figure 2 — Shape R 1 A
Figure 3 — Shape R 1 B
Designation of a connecting piece (R 1 A) with standard socket of the heavy series (1 A S) for system X of nominal size DN/ID 70
Connecting piece EN 1124-4 — R 1 A — 1 A S — X — 70
SIST EN 1124-4:2005



EN 1124-4:2005 (E) 11 Table 5 — Dimensions of short connecting pieces with weld-in sleeve Dimensions in millimetres l3 for shape s2 Nominal size DN/ID
Socket shape d1 d2 d5 a L1 R 1 A R 1 B Nominal size Toler-ance 40 42 68 71 120 42 50 50 53 80 3 122 50 60 70 73 101,6 105 125 67 80 80 89 120 123 130 74 90 100 103 135 138 130 81 100 125 133 168,3 172 135 88 110 150 159 195 198 145 97 125 200
1 A
219 273 276 150 140 170 8,0 ± 0,8 a Hole diameter in wall or floor
6.2.2.3 Long connecting pieces with weld-in sleeve For system X, long connecting p
...