Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications -- Part 10-1: Type MU-PC terminated on IEC 60793-2 category B1.1 singlemode fibre

Superseded by EN 50377-10-1:2007

Steckverbindersätze und Verbindungsbauelemente für Lichtwellenleiter-Datenübertragungssysteme - Produktnormen -- Teil 10-1: Bauart MU-PC zum Anschluss von Einmodenfasern nach IEC 60793-2, Kategorie B1.1

Jeux de connecteurs et composants d'interconnexion à utiliser dans les systèmes de communication par fibres optiques - Spécifications de produit -- Partie 10-1: Type MU-PC câblés sur une fibre unimodale de la catégorie B1.1 de la CEI 60793-2

Konektorski pribor in povezovalne komponente za uporabo v komunikacijskih sistemih s pomočjo optičnih vlaken – Specifikacije izdelka – 10-1. del: Tip MU-PC zaključen na eno-rodnem vlaknu kategorije B1 po IEC 60793-2*

General Information

Status
Withdrawn
Publication Date
31-Aug-2004
Withdrawal Date
17-Sep-2007
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
17-Sep-2007
Due Date
10-Oct-2007
Completion Date
18-Sep-2007

Relations

Buy Standard

Standard
EN 50377-10-1:2004
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 50377-10-1:2004

STANDARD
september 2004
Konektorski pribor in povezovalne komponente za uporabo v komunikacijskih
VLVWHPLKVSRPRþMRRSWLþQLKYODNHQ±6SHFLILNDFLMHL]GHOND±GHO7LS08
3&]DNOMXþHQQDHQRURGQHPYODNQXNDWHJRULMH%SR,(&
Connector sets and interconnect components to be used in optical fibre
communication systems - Product specifications - Part 10-1: MU-PC terminated on
IEC 60793-2 category B1 singlemode fibre
ICS 5HIHUHQþQDãWHYLOND
33.180.20
SIST EN 50377-10-1:2004(en)
!#"$%&’& ()$*+

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD EN 50377-10-1
NORME EUROPÉENNE
EUROPÄISCHE NORM May 2003

ICS 33.180.20


English version


Connector sets and interconnect components
to be used in optical fibre communication systems -
Product specifications
Part 10-1: Type MU-PC terminated on IEC 60793-2
category B1.1 singlemode fibre


Jeux de connecteurs et composants Steckverbindersätze und
d'interconnexion à utiliser Verbindungsbauelemente für
dans les systèmes de communication Lichtwellenleiter-
par fibres optiques - Datenübertragungssysteme -
Spécifications de produit Produktnormen
Partie 10-1: Type MU-PC câblés Teil 10-1: Bauart MU-PC zum
sur une fibre unimodale Anschluss von Einmodenfasern
de la catégorie B1.1 de la CEI 60793-2 nach IEC 60793-2, Kategorie B1.1




This European Standard was approved by CENELEC on 2002-09-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 50377-10-1:2003 E

---------------------- Page: 2 ----------------------

EN 50377-10-1:2003 - 2 -

Foreword

This European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic
connectors.

The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as
EN 50377-10-1 on 2002-09-01.

The following dates were fixed:

- latest date by which the EN has to be implemented
 at national level by publication of an identical
 national standard or by endorsement (dop) 2003-12-01

- latest date by which the national standards conflicting
 with the EN have to be withdrawn (dow) 2005-09-01
Annexes designated "normative" are part of the body of the standard.
In this standard, annexes A and B are normative.
__________

---------------------- Page: 3 ----------------------

- 3 - EN 50377-10-1:2003

Connector sets and interconnected components to be used in optical fibre
communication systems – Product specifications

Part 10-1: Type MU-PC terminated on IEC 60793-2 category B1.1 singlemode fibre

Description  Performance
Coupling mechanism: push-pull Application: EN 61753 Category U and
  ES 200 671 (see 1.3)
Configuration: plug/adaptor/plug
 Attenuation grades: P: < 0,35 dB mean.
Fibre Category: IEC 60793-2 type B1.1 (Random mate) < 1,0 dB for > 97% of measurements
  Q: < 0,30 dB mean.
Cable Type: see Table 3 < 0,60 dB for > 99% of measurements

Return loss: W: ≥ 45dB

Related documents:

EN 60794-2 Optical fibre cables - Part 2: Indoor cables - Sectional specification
EN 61300 series Fibre optic interconnection devices and passive components - Basic test and measurement
procedures
EN 61753 series Fibre optic connectors interconnecting devices and passive components performance
standard
EN 61754-6 Fibre optic connector interfaces - Part 6: Type MU connector family
ES 200 671 Transmission and Multiplexing (TM); Passive optical components; Optical fibre
connectors for single mode optical fibre communication systems; Common requirements
and conformance testing
IEC 60793-2 Optical fibres - Part 2: Product specifications

Outline and maximum dimensions:



78 Ref.
66 Ref.
53 Min.
41 Min.

---------------------- Page: 4 ----------------------

EN 50377-10-1:2003 - 4 -

Contents

1  Scope .5
1.1 Product definition .5
1.2 Intermateability.5
1.3 Operating environment .5
 1.4 Reliability.5
 1.5 Quality assurance .5
2 Normative references.5
3 Description.6
3.1 Plug.6
3.2 Adaptor .6
3.3 Materials .7
3.4 Dimensions .7
3.5 Colour and marking .7
4  Variants .7
4.1 Terminated plug.7
4.2 Adaptor .8
4.3 Identification of variants .8
5 Dimensional requirements.9
5.1 Outline dimensions .9
 5.1.1 Plug variants.9
 5.1.2 Adaptor variants.10
5.2 Mating face and other limit dimensions .11
 5.2.1 Plug .11
 5.2.2 Ferrule end face geometry after termination.13
 5.2.3 Positioning of fibre core.14
 5.2.4 Control of fibre axis .15
 5.2.5 Adaptor .16
 5.2.6 Pin gauge for adaptor .18
6  Tests .18
 6.1 Sample size .18
 6.2 Test and measurement methods .18
 6.3 Test sequence.19
 6.4 Pass/fail criteria.19
7  Test report .19
8  Performance requirements.19
 8.1 Dimensional and marking requirements.19
 8.2 Optical performance requirements.20
 8.3 Mechanical performance requirements .21
 8.4 Environmental performance requirements .25
Annex A (normative) Reference connector details .28
Annex B (normative) Sample size and product sourcing requirements.28
Bibliography .28

---------------------- Page: 5 ----------------------

- 5 - EN 50377-10-1:2003
1 Scope

1.1 Product definition

This standard contains the initial, start of life dimensional, optical, mechanical and environmental performance
requirements which a terminated and assembled singlemode resilient alignment sleeve MU-PC simplex connector
set (plug adaptor plug) must meet in order for it to be categorised as an EN standard product.

Since different variants and grades of performance are permitted, product marking details are given in 3.5.

1.2 Intermateability

Although all products conforming to the requirements of this standard will intermate, the resulting level of
random attenuation performance will only be ensured in accordance with Table 1. The intention is that this will
be true irrespective of the manufacturing source(s) of the product.

In all cases, the intermating of plug variants having different attenuation or return loss grades will result in an
uncertain level of random attenuation performance. When intermating plug variants having different return loss
grades, the resulting level of return loss can not be assured to be any better than the worst return loss grade

Similarly, the intermating of a grade P plug with a grade Q plug will result in an uncertain level of random
attenuation performance.

Table 1 - Ensured level of random attenuation

Plug variant/Attenuation grade P Q
P P P
Q P Q


1.3 Operating environment

The tests selected combined with the severities and durations are representative of an EN 61753 Category U
environment and the ES 200 671 environment.

1.4 Reliability

Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this
standard does not guarantee the reliability of the product. This should be predicted using a recognised reliability
assessment programme.

1.5 Quality assurance

Compliance with this standard does not guarantee the manufacturing consistency of the product. This should be
maintained using a recognised quality assurance programme.

2 Normative references

This European Standard incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed hereafter. For
dated references, subsequent amendments to or revisions of any of these publications apply to this European
Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the
publication referred to applies (including amendments).

EN 61300 series Fibre optic interconnection devices and passive components - Basic test and
measurement procedures
EN 61300-2-1 Part 2-1: Tests - Vibration (sinusoidal)
EN 61300-2-2 Part 2-2: Tests - Mating durability
EN 61300-2-4 Part 2-4: Tests - Fibre/cable retention
EN 61300-2-5 Part 2-5: Tests - Torsion/twist

---------------------- Page: 6 ----------------------

EN 50377-10-1:2003 - 6 -

EN 61300-2-6 Part 2-6: Tests - Tensile strength of coupling mechanism
EN 61300-2-7 Part 2-7: Tests - Bending Moment
EN 61300-2-12 Part 2-12: Tests - Impact
EN 61300-2-17 Part 2-17: Tests - Cold
EN 61300-2-18 Part 2-18: Tests - Dry heat - High temperature endurance
EN 61300-2-19 Part 2-19: Tests - Damp heat (steady state)
EN 61300-2-21 Part 2-21: Tests - Composite temperature-humidity cyclic test
EN 61300-2-22 Part 2-22: Tests - Change of temperature
EN 61300-2-26 Part 2-26: Tests - Salt mist
EN 61300-2-27 Part 2-27: Tests - Dust - Laminar flow
EN 61300-2-42 Part 2-42: Tests - Static side load for connectors
EN 61300-3-4 Part 3-4: Examinations and measurements - Attenuation
EN 61300-3-6 Part 3-6: Examinations and measurements - Return loss
EN 61300-3-10 Part 3-10: Tests- gauge retention force
EN 61300-3-23 Part 3-23: Examinations and measurements - Fibre position relative to ferrule endface
EN 61300-3-28 Part 3-28: Examinations and measurements - Transient loss
EN 61300-3-34 Part 3-34: Examinations and measurements - Attenuation of random mated connectors
EN 61753 series Fibre optic connectors interconnecting devices and passive components performance
standard
EN 186000-1 Generic Specification: Connector sets for optical fibres and cables -
Part 1: Requirements, test methods and qualification approval procedures
ES 200 671 Transmission and Multiplexing (TM); Passive optical components; Optical fibre
connectors for single mode optical fibre communication systems; Common requirements
and conformance testing


3 Description

The MU-PC connector is a single position plug connector set of plug adaptor plug configuration characterised by
a cylindrical, spring loaded butting ferrule of 1,25 mm nominal diameter and a push-pull coupling mechanism.
The optical alignment mechanism of the connectors is of a resilient sleeve style

3.1 Plug

The plug features a cylindrical zirconia ferrule and a push-pull mechanism. It has a single male key which is used
to limit and may be used to orientate, the relative rotation between mated connectors.

A cover (dustcap) to protect the ferrule endface when the connector is in the unmated condition shall be
provided.

Alternative materials may be used for the ferrule that have directly compatible material properties to the specified
materials but the endface and performance requirements must be met under all conditions

3.2 Adaptor

The adaptor has a zirconia ceramic resilient alignment sleeve. The mounting styles are duplex rectangular flange
with snap-latches with a panel cut out as SC connector and simplex rectangular flange with snap-latches.

Covers (dustcaps) shall be provided to protect each port of the adaptor.

Alternative material may be used for the sleeve that have directly compatible material properties to zirconia but
the performance requirements must be met under all conditions

---------------------- Page: 7 ----------------------

- 7 - EN 50377-10-1:2003
3.3 Materials

Materials which are not specified or which are not specifically described are left to the discretion of the
manufacturer.

3.4 Dimensions

Outline dimensions and other dimensions necessary to ensure intermateability or which affect performance are
specified. All other dimensions are left to the discretion of the manufacturer. Where the mating face limit
dimensions are not in agreement with an IEC Interface Standard this is clearly stated.

3.5 Colour and marking

Marking of the product shall be in accordance with 2.6.2 of EN 186000-1 in the following order of precedence:

a) identification of manufacturer;
b) manufacturing date code: year/week;
c) manufacturers part number;
d) variant identification number.

The following colour scheme is preferred:

Table 2 - Preferred colour scheme

Adaptor Delatch housing
Blue Blue


4 Variants

4.1 Terminated plug

The following variants are permitted:

Table 3 - Plug variants


Variant No. Fibre/Cable Structure Note
mm
P01 ∅ 0,7 - 1,4 Buffered fibre 1 fibre
P02 Reinforced cable 1 fibre
∅ 1,6 ± 0,2
P03 Reinforced cable 1 fibre
∅ 2,0 ± 0,2
Q01 Buffered fibre 1 fibre
∅ 0,7 - 1,4
Q02 Reinforced cable 1 fibre
∅ 1,6 ± 0,2
Q03 Reinforced cable 1 fibre
∅ 2,0 ± 0,2

---------------------- Page: 8 ----------------------

EN 50377-10-1:2003 - 8 -

4.2 Adaptor

The following variants are permitted:

Table 4 - Adaptor variants

Variant No. Format
A01 Simplex
A02 Rectangular flange - duplex

4.3 Identification of variants

Table 5 - Grade P plug variants

Variant number Performance grade Identification number
(Return loss)
P01 U EN 50377-10-1-P01-K
P02 U EN 50377-10-1-P02-K
P03 U EN 50377-10-1-P03-K


Table 6 - Grade Q plug variants

Variant number Performance grade Identification number
(Return loss)
Q01 U EN 50377-10-1-Q01-K
Q02 U EN 50377-10-1-Q02-K
Q03 U EN 50377-10-1-Q03-K


Table 7 - Adaptor variants

Variant number Identification number
A01 EN 50377-10-1-A01
A02 EN 50377-10-1-A02

---------------------- Page: 9 ----------------------

- 9 - EN 50377-10-1:2003
5 Dimensional requirements

5.1 Outline dimensions

5.1.1 Plug variants

Variant No. P01/Q01
BH


Ref. Dimensions Note
Min. mm Max.
BI 0,9 1,1
BH - 54


Variant No. P02, P03, Q02, Q03




BF


Ref. Dimensions Note
Min. mm Max.
BG 1,6 2,2
BF - 54

Figure 1 - Outline dimensions - Plug

---------------------- Page: 10 ----------------------

EN 50377-10-1:2003 - 10 -

5.1.2 Adaptor variants
Variant No. A01
B
D E
C
X
F A
Ref. Dimensions Note
Min. mm Max.
A 26,0 26,4
B 1,65 1,75
C 9,4 9,8
D 7,0 7,2
E 9,4 9,8
F 10,4 10,6
X 10,75 10,85
Z 7,35 7,45
NOTE  Panel cut out: panel thickness should be between 1,2 mm and 1,7 mm.

Variant No. A02
Z
H
G
I
F
A W
Ref. Dimensions Note
Min. mm Max.
A 27,0 27,8
B 17,5 18,5
C 12,5 13,0
D 21,8 22,5 1
E 14,4 15,4
F 9,2 9,4 1
G 2,8 3,2
H 2,2 2,6 Diameter
I 1,7 2,0 2
W 2,4 2,6 Diameter
X 13,1 13,6
Y 17,9 18,1
Z 9,5 10,0
NOTE 1  The dotted lines indicate an example of the shape of the mounting flange. The largest portion of the mounting flange shall be
within these dimensions.
NOTE 2  If the adaptor is mounted using this hook, the thickness of the panel shall be 1,6 mm.
Figure 2 - Outline dimensions - Adaptor
D
B
C
E
X
Y

---------------------- Page: 11 ----------------------

- 11 - EN 50377-10-1:2003
5.2 Mating face and other limit dimensions

5.2.1 Plug


Figure 3 - Plug connector interface reference planes

---------------------- Page: 12 ----------------------

EN 50377-10-1:2003 - 12 -


Ref. Dimensions Note
Min. mm Max.
A 1,248 5 1,249 5 Diameter, 1
B 2,6 2,7 Diameter
C 4,6 4,8
D 4,65 4,75
E 4,3 4,4
F 3,3 4,4
G 25 35 Degree
H 25 35 Degree
I 6,55 6,65
J 4,2 4,5 5
K 5,5 5,6
L 2,4 2,5
M 1,5 1,7
N 0,6 0,9
O 0,5 0,55
P 2,6 2,8
Q 1 1,1
R 2,65 2,9
S 5,5 5,6
T 4,3 4,5
U 3,6 3,7
V 2,3 2,4
W 6,5 6,6
AA 4,3 4,4
AB 3,85 3,95
AC 0,7 0,9
AD 0,2 0,4
AE 3 3,1
AF 2,2 2,3

Figure 3 - Plug connector interface reference planes (concluded)

---------------------- Page: 13 ----------------------

- 13 - EN 50377-10-1:2003
5.2.2 Ferrule endface geometry after termination
Note 5
BK
DETAIL A
BG
A BF
Note 3
BI

Ref. Dimensions Note
Min. mm Max.
BF 7 25 1,4
BG 0,60 0,85 Diameter
BI 32,5 37,5 Degree
BK - 0,000 1 Figure 4b 2,3

Figure 4a - Ferrule endface geometry - After termination
Allowable undercut versus ferrule endface radius
140
120
100
80
60
40
20
0
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Ferrule Endface Radius (mm)

3 2
The
...

Questions, Comments and Discussion