Conducted transmission networks -- Part 2: Coaxial cables (CaTV-based)

This EMC standard specifies limits and methods of measurement for emissions originating from within traditional telecommunication networks and the immunity of those networks, including their in-premises extensions by references to harmonised product standards in combination with good engineering practice, when installed and operated as intended. This standard covers the frequency range 9 kHz to 400 GHz. To date, it specifies limits and methods of measurement for conducted and radiated disturbances from telecommunication networks in the frequency range 150 kHz to 6 GHz. The assessment of a network needs to be performed only in the frequency ranges where limits are defined. The emission limits set in this standard do not apply to the wanted emissions from embedded radio links within the network. The requirements have been selected so as to ensure that electromagnetic disturbances generated by a network, or parts thereof, operating normally do not exceed a level that could prevent other equipment from operating as intended. Fault conditions of the network are not taken into account.

EMV-Norm für Übertragungsnetze - Teil 2: Leitungsgebundene Übertragungsnetze, die Koaxialkabel nutzen

Norme CEM pour les réseaux de télécommunications - Partie 2: Réseaux de télécommunications filaires utilisant des câbles coaxiaux

La présente norme CEM spécifie les exigences pour les émissions émanant de l'intérieur des réseaux de télécommunications filaires utilisant des câbles coaxiaux et l'immunité de ces réseaux, y compris leurs extensions dans les locaux par des références à des normes de produits CEM harmonisées et à d'autres normes comportant des exigences CEM en combinaison avec les règles de l'art, lorsqu'ils sont installés et mis en fonctionnement comme prévu. La présente norme couvre la bande de fréquences comprises entre 9 kHz et 400 GHz. Il n'est nécessaire d'évaluer un réseau que dans les bandes de fréquences où les limites sont définies. Les limites d'émission fixées dans la présente norme ne s'appliquent pas aux émissions désirées provenant de liaisons radio intégrées au sein du réseau. Les exigences ont été sélectionnées de manière à assurer que les perturbations électromagnétiques engendrées par un réseau, ou des parties de celui-ci, fonctionnant normalement n'excéderont pas un niveau au-dessus duquel des appareils de radiocommunications ou de télécommunications ou autres appareils ne pourront pas fonctionner comme prévu. Les états de pannes du réseau ne sont pas pris en compte.

Prenosna omrežja z vodniki - 2. del: Koaksialni kabli (izhodišče: kabelska TV)

Ta standard o elektromagnetni združljivosti določa mejne vrednosti in metode merjenja za emisije, ki izvirajo iz tradicionalnih telekomunikacijskih omrežij, in odpornost teh omrežij, vključno z njihovimi priključki v prostoru, s sklicevanjem na usklajene standarde o proizvodih v kombinaciji z dobro inženirsko prakso, kadar so nameščena in delujejo, kot je predvideno. Ta standard zajema frekvenčni razpon od 9 kHz do 400 GHz. Trenutno določa mejne vrednosti in metode merjenja za vodene in oddajane motnje iz telekomunikacijskih omrežij v frekvenčnem razponu od 150 kHz do 6 GHz. Ocenjevanje omrežja mora biti izvedeno samo v frekvenčnih razponih, kjer so opredeljene omejitve. Mejne vrednosti emisij, postavljene v tem standardu, ne veljajo za želene emisije iz vdelanih radijskih povezav v omrežju. Zahteve so bile izbrane tako, da zagotovijo, da elektromagnetne motnje, ki jih ustvarja omrežje ali njegovi deli ob običajnem delovanju, ne presežejo stopnje, nad katero druga oprema ne more delovati, kot je predvideno. Okoliščine okvare omrežja niso upoštevane.

General Information

Status
Published
Public Enquiry End Date
31-Jan-2008
Publication Date
23-Jan-2011
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
17-Dec-2010
Due Date
21-Feb-2011
Completion Date
24-Jan-2011

Buy Standard

Standard
SIST EN 50529-2:2011
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN 50529-2:2011
01-februar-2011
3UHQRVQDRPUHåMD]YRGQLNLGHO.RDNVLDOQLNDEOL L]KRGLãþHNDEHOVND79
Conducted transmission networks -- Part 2: Coaxial cables (CaTV-based)

EMV-Norm für Übertragungsnetze - Teil 2: Leitungsgebundene Übertragungsnetze, die

Koaxialkabel nutzen
Norme CEM pour les réseaux de télécommunications - Partie 2: Réseaux de
télécommunications filaires utilisant des câbles coaxiaux
Ta slovenski standard je istoveten z: EN 50529-2:2010
ICS:
33.040.20 Prenosni sistem Transmission systems
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
SIST EN 50529-2:2011 en,fr

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 50529-2:2011
---------------------- Page: 2 ----------------------
SIST EN 50529-2:2011
EUROPEAN STANDARD
EN 50529-2
NORME EUROPÉENNE
November 2010
EUROPÄISCHE NORM
ICS 33.060.40
English version
EMC Network Standard -
Part 2: Wire-line telecommunications networks using coaxial cables
Norme CEM pour les réseaux de EMV-Norm für Übertragungsnetze -
télécommunications - Teil 2: Leitungsgebundene
Partie 2 : Réseaux de télécommunications Übertragungsnetze, die Koaxialkabel
filaires utilisant des câbles coaxiaux nutzen

This European Standard was approved by CENELEC on 2010-11-01. CENELEC members are bound to comply

with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard

the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on

application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other

language made by translation under the responsibility of a CENELEC member into its own language and notified

to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,

the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,

Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,

Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 50529-2:2010 E
---------------------- Page: 3 ----------------------
SIST EN 50529-2:2011
EN 50529-2:2010 – 2 –
Foreword

This European Standard was prepared by the Joint CENELEC – ETSI Working Group “EMC of conducted

transmission networks”. It was submitted to the formal vote and wes approved by CENELEC as

EN 50529-2 on 2010-11-01.

Attention is drawn to the possibility that some of the elements of this document may be the subject of

patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent

rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-11-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2013-11-01

This European Standard has been prepared under Mandate M/313 given to CENELEC and ETSI by the

European Commission and the European Free Trade Association and covers essential requirements of

EC Directive 2004/108/EC . See Annex ZZ.
__________
—————————

Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of

the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC,

OJ L 390, 31.12.2004, p. 24-37.
---------------------- Page: 4 ----------------------
SIST EN 50529-2:2011
– 3 – EN 50529-2:2010
Contents

Introduction .............................................................................................................................................4

1 Scope ...............................................................................................................................................5

2 Normative references ......................................................................................................................5

3 Terms, definitions and abbreviations ...........................................................................................6

3.1 Terms and definitions ..............................................................................................................6

3.2 Abbreviations ..........................................................................................................................8

4 EMC requirements for networks ....................................................................................................8

4.1 Introduction .............................................................................................................................8

4.2 Apparatus for wire-line telecommunications networks using coaxial cables ..........................8

Annex A (informative) Example of good engineering practice.........................................................9

A.1 General provisions ..................................................................................................................9

A.2 Provisions for coaxial cables and coaxial cable assemblies...................................................9

A.3 Provisions for cable networks for television signals, sound signals and interactive services

using coaxial cables ............................................................................................................. 11

Annex ZZ (informative) Coverage of Essential Requirements of EC Directives .......................... 12

Bibliography ......................................................................................................................................... 13

Tables

Table 1 – Harmonised EMC standards for coaxial cable network equipment .........................................8

Table A.1 – Standards for coaxial cables with EMC requirements ....................................................... 10

Table A.2 – Standards for coaxial cable assemblies with EMC requirements ...................................... 11

---------------------- Page: 5 ----------------------
SIST EN 50529-2:2011
EN 50529-2:2010 – 4 –
Introduction

This part of the multi-part EMC standard specifies limits and methods of measurement for emissions

emanating from wire-line telecommunication networks and immunity of those networks by means of

references to harmonised product standards in combination with good engineering practice. This

standard specifically refers to networks using coaxial cables.
---------------------- Page: 6 ----------------------
SIST EN 50529-2:2011
– 5 – EN 50529-2:2010
1 Scope

This EMC standard specifies requirements for emissions originating from within wire-line

telecommunication networks using coaxial cables and the immunity of those networks, including their in-

premises extensions by references to harmonised EMC product standards and other standards with EMC

requirements in combination with good engineering practice, when installed and operated as intended.

This standard covers the frequency range 9 kHz to 400 GHz. The assessment of a network needs to be

performed only in the frequency ranges where limits are defined.

The emission limits set in this standard do not apply to the wanted emissions from embedded radio links

within the network.

The requirements have been selected so as to ensure that electromagnetic disturbances generated by a

network, or parts thereof, operating normally do not exceed a level above which radio and

telecommunications apparatus or other apparatus cannot operate as intended. Fault conditions of the

network are not taken into account.
2 Normative references

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.

EN 50083-2:2006 Cable networks for television signals, sound signals and interactive

services – Part 2: Electromagnetic compatibility for equipment
EN 55022:2006 + Information technology equipment – Radio disturbance
A1:2007 characteristics – Limits and methods of measurement
(CISPR 22:2005, mod. + A1:2005)
EN 55024:1998 + Information technology equipment – Immunity characteristics –
A1:2001 + Limits and methods of measurement (CISPR 24:1997, mod. +
A2:2003 A1:2001 + A2:2002)

ETSI EN 300 386: V1.4.1 Electromagnetic compatibility and Radio spectrum Matters (ERM);

2)
(2008-04) Telecommunication network equipment; ElectroMagnetic
Compatibility (EMC) requirements
IEC 60050-161:1990 + International Electrotechnical Vocabulary – Chapter 161:
A1:1997 + Electromagnetic compatibility
A2:1998
IEC 60050-723:1997 + International Electrotechnical Vocabulary – Chapter 723:
A1:1999 Broadcasting: Sound, television, data
Sound and television broadcast receivers and associated
EN 55013:2001
equipment - Radio disturbance characteristics - Limits and methods
of measurement (CISPR 13:2001, mod.)
EN 55020:2007 Sound and television broadcast receivers and associated
equipment - Immunity characteristics - Limits and methods
of measurement (CISPR 20:2006)
—————————
And all previous editions listed in the OJEC.
---------------------- Page: 7 ----------------------
SIST EN 50529-2:2011
EN 50529-2:2010 – 6 –
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1.1
active equipment

equipment (e.g. amplifiers, converters, etc.), performing signal processing by means of external or

internal power supply in a certain frequency range
3.1.2
cable network equipment

equipment from which cable networks for television signals, sound signals and interactive services are

built

NOTE Examples of typical cable network equipment could be found in Part 3 to Part 6 and Part 10 of the EN 60728 series.

3.1.3
degradation (of performance)

undesired departure in the operational performance of any device, equipment or system from its intended

performance
NOTE The term "degradation" can apply to temporary or permanent failure.
[IEV 161-01-19]
3.1.4
electromagnetic disturbance

any electromagnetic phenomenon which may degrade the performance of a device, equipment or

system, or adversely affect living or inert matter

NOTE An electromagnetic disturbance may be an electromagnetic noise, an unwanted signal or a change in the propagation

medium itself.
[IEV 161-01-05]
3.1.5
electronic communications network

means transmission systems and, where applicable, switching or routing equipment and other resources

which permit the conveyance of signals by wire, by radio, by optical or by other electromagnetic means,

including satellite networks, fixed (circuit- and packet-switched, including Internet) and mobile terrestrial

networks, electricity cable systems, to the extent that they are used for the purpose of transmitting

signals, networks used for radio and television broadcasting, and cable televisionnetworks, irrespective of

the type of information conveyed
[Derived from Art.2.a) of Directive 2002/21/EC [1] (Framework Directive)]
3.1.6
emission
phenomenon by which electromagnetic energy emanates from a source
[IEV 161-01-08]
3.1.7
equipment

for the purposes of this standard ‘equipment’ means any apparatus or fixed installation

---------------------- Page: 8 ----------------------
SIST EN 50529-2:2011
– 7 – EN 50529-2:2010
3.1.8
headend

equipment, which is connected between receiving antennas or other signal sources and the remainder of

the cable network, to process the signals to be distributed
[IEV 723-09-11, modified]

NOTE The headend may, for example, comprise antenna amplifiers, frequency converters, combiners, separators and generators.

3.1.9
immunity (to a disturbance)

ability of a device, equipment or system to perform without degradation in the presence of an

electromagnetic disturbance
[IEV 161-01-20]
3.1.10
network cable
cable infrastructure (transmission line) used to connect together equipment
3.1.11
passive equipment

equipment (e.g. splitters, tap-offs, system outlets, etc.) not requiring a power supply in order to operate

and/or not carrying out signal processing in a certain frequency range
3.1.12
(electromagnetic) radiation

1. phenomenon by which energy in the form of electromagnetic waves emanates from a source into

space
2. energy transferred through space in the form of electromagnetic waves

NOTE By extension, the term "electromagnetic radiation" sometimes also covers induction phenomena.

[IEV 161-01-10]
3.1.13
screening effectiveness

ability of an equipment or system to attenuate the influence of electromagnetic fields from outside the

equipment or system or to suppress the radiation of electromagnetic fields from inside the equipment or

system
3.1.14
(surface) transfer impedance (of a coaxial line)

quotient of the voltage induced in the centre conductor of a coaxial line per unit length by the current on

the external surface of the coaxial line
[IEV 161-04-15]
3.1.15
wire-line telecommunication network

combination of equipment and passive devices (network cables, connectors) interconnected together to

constitute the wire-line part of an electronic communications network
---------------------- Page: 9 ----------------------
SIST EN 50529-2:2011
EN 50529-2:2010 – 8 –
3.2 Abbreviations
For the purposes of this document, the following abbreviations apply.
CENELEC European Committee for Electrotechnical Standardization
CISPR International Special Committee on Radio Interference
EMC Electromagnetic Compatibility
ETSI European Telecommunications Standards Institute
IEC International Electrotechnical Commission
IEV International Electrotechnical Vocabulary
4 EMC requirements for networks
4.1 Introduction
Assuming that apparatus meets the EMC requirements defined in t
...

Questions, Comments and Discussion