Furniture - Assessment of the ignitability of upholstered furniture - Part 1: Ignition source smouldering cigarette

This European Standard specifies a test method to assess the ignitability of material combinations, such as covers and fillings used in upholstered seating, when subjected to a smouldering cigarette as an ignition source.
The test measures only the ignitability of a combination of materials used in upholstered seating and not the ignitability of a particular finished item of furniture incorporating these materials. They give an indication of, but cannot guarantee, the ignition behaviour of the finished item of furniture.
NOTE   Test specimens prepared from materials taken from furniture that has been used may give different results to the same materials before use.

Möbel - Bewertung der Entzündbarkeit von Polstermöbeln - Teil 2: Eine einem Streichholz vergleichbare Gasflamme als Zündquelle

Diese Europäische Norm legt ein Prüfverfahren zur Bestimmung der Entzündbarkeit von
Werkstoffkombinationen wie Bezüge und Füllmaterial für gepolsterte Sitzmöbel fest, wenn diese einer
glimmenden Zigarette als Zündquelle ausgesetzt sind.
Anhand der Prüfungen wird lediglich die Entzündbarkeit einer Kombination von Werkstoffen bestimmt, die zur
Herstellung von Polstermöbeln verwendet wird, nicht aber die Entzündbarkeit eines bestimmten fertigen
Möbelstücks, das unter anderem aus diesen Werkstoffen besteht. Diese Prüfungen geben einen Anhaltspunkt,
jedoch keine Garantie für das Entzündungsverhalten des fertigen Möbelstücks.
ANMERKUNG Proben, die aus gebrauchten Möbeln entnommen wurden, können andere Ergebnisse liefern als Proben
aus den gleichen, aber ungebrauchten Möbeln.

Ameublement - Evaluation de l'allumabilité des meubles rembourrés - Partie 1 : Source d'allumage : cigarette en combustion

La présente Norme européenne décrit une  méthode d’essai destinée a évaluer l’allumabilité de combinaisons de matériaux, comme des revetements et des rembourrages de sieges, lorsque la source d’allumage a laquelle ils sont exposés est une cigarette en combustion.
Cet essai mesure uniquement l’allumabilité d’une combinaison de matériaux utilisés dans les sieges rembourrés et non l’allumabilité d’un article d’ameublement fini particulier qui incorpore ces matériaux. Ils donnent une indication mais ne peuvent garantir le comportement de l’article d’ameublement fini a l’allumage.
NOTE   Les éprouvettes préparées a partir de matériaux prélevés sur des meubles ayant déja servi sont susceptibles de donner des résultats différents de ceux obtenus sur ces memes matériaux avant leur utilisation.

Pohištvo - Ugotavljanje vžigljivosti oblazinjenega pohištva - 1. del: Vir vžiga: tleča cigareta

General Information

Status
Withdrawn
Publication Date
28-Feb-2006
Withdrawal Date
18-Aug-2014
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
18-Aug-2014
Due Date
10-Sep-2014
Completion Date
19-Aug-2014

Relations

Buy Standard

Standard
EN 1021-1:2006
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 1021-1:2006
01-marec-2006
1DGRPHãþD
SIST EN 1021-1:1995
3RKLãWYR8JRWDYOMDQMHYåLJOMLYRVWLREOD]LQMHQHJDSRKLãWYDGHO9LUYåLJDWOHþD
FLJDUHWD
Furniture - Assessment of the ignitability of upholstered furniture - Part 1: Ignition source
smouldering cigarette
Möbel - Bewertung der Entzündbarkeit von Polstermöbeln - Teil 2: Eine einem
Streichholz vergleichbare Gasflamme als Zündquelle
Ameublement - Evaluation de l'allumabilité des meubles rembourrés - Partie 1 : Source
d'allumage : cigarette en combustion
Ta slovenski standard je istoveten z: EN 1021-1:2006
ICS:
13.220.40 Sposobnost vžiga in Ignitability and burning
obnašanje materialov in behaviour of materials and
proizvodov pri gorenju products
97.140 Pohištvo Furniture
SIST EN 1021-1:2006 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 1021-1:2006

---------------------- Page: 2 ----------------------

SIST EN 1021-1:2006
EUROPEAN STANDARD
EN 1021-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2006
ICS 13.220.40; 97.140 Supersedes EN 1021-1:1993
English Version
Furniture - Assessment of the ignitability of upholstered furniture
- Part 1: Ignition source smouldering cigarette
Ameublement - Evaluation de l'allumabilité des meubles Möbel - Bewertung der Entzündbarkeit von Polstermöbeln -
rembourrés - Partie 2 : Source d'allumage : flamme Teil 2: Eine einem Streichholz vergleichbare Gasflamme
équivalente à celle d'une allumette als Zündquelle
This European Standard was approved by CEN on 16 December 2005.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,
Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2006 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 1021-1:2006: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
Contents Page
Foreword. 3
Introduction . 4
1 Scope. 5
2 Terms and definitions . 5
3 Criteria of ignition. 5
4 Principle . 6
5 Health and safety of operators . 6
6 Apparatus. 7
7 Preparation and conditioning. 10
8 Test assembly. 10
9 Test procedure. 11
10 Test report. 14
Annex A (informative) Guidance notes for designers and specifiers . 16

Annex B (informative) Model report form. 18
Annex C (informative) Cleaning of a rig . 19
Annex D (normative) Water soak procedures . 20

2

---------------------- Page: 4 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
Foreword
This European Standard (EN 1021-1:2006) has been prepared by Technical Committee CEN/TC 207
“Furniture”, the secretariat of which is held by UNI.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by August 2006, and conflicting national standards shall be
withdrawn at the latest by August 2006.
This European Standard supersedes EN 1021-1:1993.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
3

---------------------- Page: 5 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
Introduction
This European Standard is one of a series of standards concerned with the ignitability of upholstered
furniture using different ignition sources. The ignition source used in this European Standard is a
smouldering cigarette.
4

---------------------- Page: 6 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
1 Scope
This European Standard specifies a test method to assess the ignitability of material combinations, such as
covers and fillings used in upholstered seating, when subjected to a smouldering cigarette as an ignition
source.
The test measures only the ignitability of a combination of materials used in upholstered seating and not
the ignitability of a particular finished item of furniture incorporating these materials. They give an indication
of, but cannot guarantee, the ignition behaviour of the finished item of furniture.
NOTE Test specimens prepared from materials taken from furniture that has been used may give different results
to the same materials before use.
2 Terms and definitions
For the purposes of this European Standard, the following terms and definitions apply.
2.1
progressive smouldering
exothermic oxidation, not accompanied by flaming, that is self-propagating, i.e. independent of the ignition
source. It may or may not be accompanied by incandescence
2.2
flaming
undergoing combustion in the gaseous phase with the emission of light
2.3 Cover
2.3.1
outer cover
outer layer of the upholstery
2.3.2
inner cover
thin layer of material used between the outer cover and the upholstery filling. Any inner cover greater than
nominally 2 mm thick is part of the filling for test purposes
NOTE The term “interliner” is no longer used because it is non-specific and has been applied to different
components within the composite.
2.4
filling
main upholstery material contained by the outer cover and (if used) the inner cover. It may consist of
several different materials including any inner cover nominally greater than 2 mm thick
3 Criteria of ignition
3.1 Progressive smouldering ignition
For the purposes of this European Standard, all the following types of behaviour are considered to be
progressive smouldering ignitions:
a) any test assembly that displays escalating combustion behaviour so that it is unsafe to continue the
test and active extinction is necessary;
5

---------------------- Page: 7 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
b) any test assembly that smoulders until it is largely consumed within the test duration;
c) any test assembly that smoulders to the extremities of the specimen, viz. upper or lower margins,
either side or to its full thickness, within the duration of the test;
d) any test assembly that smoulders after one hour from the beginning of the test;
e) any test assembly that, on final examination (see 9.3), shows evidence of active smouldering.
NOTE In practice it has been found that there is usually a clear distinction between materials which may char
under the influence of the ignition source but which do not propagate further (non-progressive combustion) and those
where smouldering develops in extent and spreads (progressive combustion).
3.2 Flaming ignition
For the purposes of this European Standard, a flaming ignition is considered to be the occurrence of any
flames initiated by a smouldering source.
4 Principle
To subject an assembly of upholstery materials to a smouldering cigarette ignition source. The assembly is
arranged to represent in stylised form a junction between a seat and back (or seat and arm) such as might
occur in a typical chair. The ignitability of an assembly is determined by applying smokers materials such
as a cigarette. The test method measures the ignitability of the overall composite of materials, i.e. outer
cover, inner cover, filling etc., as constructed on the test rig. The results shall not be stated as being
applicable to the general behaviour of any individual component (see also Annex A).
5 Health and safety of operators
5.1 General
The test method specified in this European Standard presents a considerable hazard; suitable precautions
shall be taken.
5.2 Enclosure
For safety, the test should be conducted in a non-combustible fume cupboard. If such a cupboard is not
available, a test enclosure should be constructed (see 6.2) so that the operator is protected from the fumes.
5.3 Extinguishers
Adequate means of extinguishing the assembly should be provided bearing in mind that some
combinations may produce severe flaming during the test. A hand and/or fixed water spray which can be
directed over the burning area can be useful. Other means such as suitable fire extinguishers, fire blankets
and a bucket of water will assist.
In some cases smouldering may be difficult to extinguish completely and complete immersion in water may
be necessary.
6

---------------------- Page: 8 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
6 Apparatus
6.1 Test rig
A suitable test rig is illustrated in Figures 1 and 2. It shall consist of two rectangular frames hinged together
and capable of being locked at right angles to each other.


Key
a) test rig
b) test rig with cover and fillings
c) vertical section
X detail of fitting cover to frame
1 filling
2 end plate of frame
3 cover
4 overlap 20 mm
5 clips
6 fold cover overlap under frame to touch the steel mesh supporting the filling and fasten with clips as
below
Figure 1 — Test rig assembly
7

---------------------- Page: 9 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
Dimensions in millimetres

NOTE 1 Unless tolerances are indicated, dimensions are nominal.
NOTE 2 All parts are made of steel.
Key
1 end plate of frame 65 mm x 3 mm
2 edging section
3 expanded metal mesh size 28 mm x 6 mm (see 6.1)
4 side member of frame 25 mm x 3 mm
5 M10 bolt, nut and washers
6 Ø 10 hinge rod
Figure 2 — Test rig detail
8

---------------------- Page: 10 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
The sides and hinge edges of the frames shall be made from nominal 25 mm x 3 mm steel flat bar and
shall securely hold mesh steel platforms set (6 ± 1) mm below the top edge of the frames. (Mesh size
2
should be such that an open mesh area of approximately 15 mm² to 150 mm exists).
The upper edge of the vertical frame and the front edge of the horizontal frame shall be steel end plates
450 mm x 65 mm x 3 mm to prevent the test filling moving during the assembly of the test specimen (see
Figures 1 and 2).
The internal width and height of the back frame shall be (450 ± 2) mm x (300 ± 2) mm and the width and
depth of the base frame (450 ± 2) mm x (150 ± 2) mm. A standard edging section may be used around the
mesh steel platform to give protection and greater rigidity.
The sides of the frame shall extend beyond the back of each frame to provide for the hinge holes and to
form the back legs. The hinge rod shall be of nominal 10 mm diameter steel, continuous across the back of
the rig and its axis (22,5 ± 0,5) mm beyond the back member of each frame.
The frames shall be lockable at right angles by a bolt or pin through each of the pairs of members forming
the back legs. The front legs may be welded across the front corners of the base frame. The height of the
legs shall be such as to leave a gap not less than 50 mm high between the base and frame and the
supporting surface.
For the tests the rigs shall be sited within the enclosure (see 6.2) and the testing shall be performed in a
basically draught-free environment permitting an adequate supply of air and removal of smoke from the
area of the apparatus.
6.2 Test enclosure
3
The test enclosure shall consist of either a room with a volume greater than 20 m (which contains
adequate oxygen for testing) or a smaller enclosure with a through flow of air. Inlet and extraction systems
providing an air flow rate of less than 0,2 m/s in the locality of the rig provide adequate oxygen without
disturbing the burning behaviour.
6.3 Clock
The clock shall be capable of measuring to at least 1 h with an accuracy of 1 s.
6.4 Ignition source smouldering cigarette
An un-tipped cylindrical cigarette complying with the following requirements shall be used:
 length: (68 ± 2) mm;
 diameter: (8 ± 0,5) mm;
 mass: (0,95 ± 0,1) g.
The smouldering rate shall be (8 ± 2) min/40 mm, when tested as follows.
Mark the cigarette, conditioned as described in 7.2 at 10 mm and 50 mm from the end to be lit. Light it as
described in 9.2.1 and impale it horizontally in air (air flow rate less than 0,2 m/s) on a horizontal wire spike
inserted not more than 13 mm into the unlit end. Record the time taken to smoulder from the 10 mm to the
50 mm mark.
The smouldering rate may be measured on two cigarettes at the same time. The distance between
cigarettes and between each cigarette and any nearby surface such as the wall or floor of the test
enclosure shall be at least 150 mm.
9

---------------------- Page: 11 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
7 Preparation and conditioning
7.1 Preparation
All outer covers and inner covers that have been chemically treated to reduce their ignitability shall be
subjected to the water soaking and drying procedure described in Annex D prior to being conditioned
according to 7.2. This requirement applies to all methods of treatment, including back coating, which are
applied to material covers that are finished in all other respects. It does not apply when the cover material
is manufactured from materials that are formulated to be, or are inherently, flame retardant (e.g. fabric
woven from inherently flame retardant yarns, PVC) provided it is not further treated as a finished cover
material.
Where it is not known whether the material has been so treated or not, the water soaking and drying
procedure shall be carried out.
7.2 Conditioning
Foam materials shall not be tested for at least 72 h after manufacture. All materials to be tested and the
cigarettes shall be conditioned for at least 24 h immediately before the tests in the following atmosphere;
 temperature: (23 ± 2) °C;
 relative humidity: (50 ± 5) %.
7.3 Atmosphere for testing
The test shall be carried out in an atmosphere having a temperature between 10 °C and 30 °C and a
relative humidity between 15 % and 80 %.
8 Test assembly
8.1 General
The test assembly materials shall be representative samples of the cover, inner cover, filling and other
components, which may be used in a real assembly.
NOTE The test assemblies may be made up with identical materials in the horizontal and vertical sections.
8.2 Cover materials
The outer cover (2.3.1) size needed for each test shall be
+10 +10
800 mm × 650 mm
  0  0
NOTE The cover should be cut to these dimensions after the soaking procedure.
The long dimensions shall be cut parallel to the machine direction. The cover may be constructed from
smaller pieces of material, provided that the location of the resulting seams does not occur within 50 mm of
the area likely to be affected by the test.
The cover shall have cut-outs 325 mm from one end on both sides. The cut-outs shall be positioned so that
when assembled on the test rig, the lay of the pile is down the back assembly and from the hinge to the
front of the base frame. The size of these cut-outs shall be approximately 50 mm base width x 100 mm
height x 25 mm top width.
10

---------------------- Page: 12 ----------------------

SIST EN 1021-1:2006
EN 1021-1:2006 (E)
Where an inner cover (2.3.2) is used, it shall be cut to the same dimensions and in the same orientation as
the outer cover, for fitting to the test rig under the cover.
Some special products may consist of fabrics bonded to sub-layers of flexible padding etc. When these are
to be tested, the material shall be cut to the cover size. The lower layers shall be considered to be part of
the filling (see 8.3) and the thickness reduced to ensure the total thickness complies with the specification
limits.
8.3 Upholstery filling
Two pieces of filling are necessary
...