Protective gloves and other hand protective equipments against thermal risks (heat and/or fire)

This European Standard specifies requirements, test methods, marking and information for protective gloves against heat and/or flame and hands protective equipment against domestic thermal risks.
It should be used for all gloves and hands protective equipment which protect the hands or part of the hand against heat and/or flame in one or more of the following forms: flame, contact heat, convective heat, radiant heat, small splashes or large quantities of molten metal.
This standard is only applicable in conjunction with EN 420.
There are other standards relevant to specific applications, as for example fire-fighting or welding.
Product tests may only give performance levels and not protection levels.

Schutzhandschuhe und andere Handschutzausrüstung gegen thermische Risiken (Hitze und/oder Feuer)

Diese Europäische Norm legt Anforderungen, Prüfverfahren, Kennzeichnungen und Herstellerinformationen für Schutzhandschuhe gegen Hitze und/oder Feuer sowie Handschutzausrüstung zum Schutz gegen thermische Risiken im Haushaltsbereich fest.
Sie sollte für alle Handschuhe und Handschutzausrüstung zum Schutz der Hände oder eines Teils der Hand gegen Hitze und/oder Feuer in einer oder mehrerer der folgenden Formen angewendet werden: Feuer, Kontaktwärme, konvektive Wärme, Strahlungswärme, kleine Spritzer geschmolzenen Metalls und große Mengen flüssigen Metalls.
Diese Norm ist nur zusammen mit EN 420 anzuwenden.
Spezifische Anwendungen, z. B. Brandbekämpfung oder Schweißen, werden in anderen Normen behandelt.
Produktprüfungen können nur für Leistungsstufen und nicht für Schutzstufen erfolgen.

Gants de protection et autres équipements de protection de la main contre les risques thermiques (chaleur et/ou feu)

La présente Norme européenne spécifie les exigences, les méthodes d'essai, le marquage et les informations liés aux gants de protection contre la chaleur et/ou les flammes et aux équipements de protection des mains contre les risques thermiques domestiques.
Il convient qu’elle soit appliquée à tous les gants et à tous les équipements de protection des mains qui protègent la main ou une partie de la main contre la chaleur et/ou les flammes sous l’une ou plusieurs des formes suivantes : flamme, chaleur de contact, chaleur convective, chaleur radiante et petites projections ou grosses projections de métal fondu.
La présente norme s’applique uniquement en association avec l’EN 420.
D’autres normes relatives à des applications spécifiques existent, comme par exemple la lutte contre les incendies ou la soudure.
Les essais de produits ne peuvent donner que des niveaux de performances et non des niveaux de protection.

Varovalne rokavice in druga oprema za zaščito rok pred toplotnimi tveganji (toplote in/ali ognja)

General Information

Status
Published
Public Enquiry End Date
19-Nov-2017
Publication Date
21-May-2020
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
16-Apr-2020
Due Date
21-Jun-2020
Completion Date
22-May-2020

RELATIONS

Buy Standard

Standard
SIST EN 407:2020
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN 407:2020
01-junij-2020
Nadomešča:
SIST EN 407:2004
Varovalne rokavice in druga oprema za zaščito rok pred toplotnimi tveganji
(toplote in/ali ognja)

Protective gloves and other hand protective equipments against thermal risks (heat

and/or fire)
Schutzhandschuhe und andere Handschutzausrüstung gegen thermische Risiken (Hitze
und/oder Feuer)

Gants de protection et autres équipements de protection de la main contre les risques

thermiques (chaleur et/ou feu)
Ta slovenski standard je istoveten z: EN 407:2020
ICS:
13.340.40 Varovanje dlani in rok Hand and arm protection
SIST EN 407:2020 en,fr,de

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 407:2020
---------------------- Page: 2 ----------------------
SIST EN 407:2020
EN 407
EUROPEAN STANDARD
NORME EUROPÉENNE
April 2020
EUROPÄISCHE NORM
ICS 13.340.40 Supersedes EN 407:2004
English Version
Protective gloves and other hand protective equipments
against thermal risks (heat and/or fire)

Gants de protection et autres équipements protecteur Schutzhandschuhe und andere Handschutzausrüstung

de la main contre les risques thermiques (chaleur gegen thermische Risiken (Hitze und/oder Feuer)

et/ou feu)
This European Standard was approved by CEN on 21 October 2019.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this

European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references

concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN

member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by

translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management

Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,

Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,

Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and

United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels

© 2020 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 407:2020 E

worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
Contents Page

European foreword ................................................................................................................................................. 3

Introduction ............................................................................................................................................................... 4

1 Scope .............................................................................................................................................................. 5

2 Normative references............................................................................................................................... 5

3 Terms and definitions .............................................................................................................................. 6

4 General requirements .............................................................................................................................. 7

4.1 General .......................................................................................................................................................... 7

4.2 Cleaning ......................................................................................................................................................... 7

4.3 Mechanical strength ................................................................................................................................. 8

4.4 Sizes and dimensions ............................................................................................................................... 8

4.5 Thermal performances ............................................................................................................................ 8

5 Sampling and conditioning .................................................................................................................. 11

6 Test methods ............................................................................................................................................. 11

6.1 General ........................................................................................................................................................ 11

6.2 Limited flame spread.............................................................................................................................. 12

6.3 Contact heat ............................................................................................................................................... 14

6.4 Convective heat ........................................................................................................................................ 14

6.5 Radiant heat ............................................................................................................................................... 15

6.6 Small splashes of molten metal .......................................................................................................... 16

6.7 Large quantities of molten metal ....................................................................................................... 16

6.8 Tear resistance ......................................................................................................................................... 17

7 Marking ....................................................................................................................................................... 20

8 Information supplied by the manufacturer ................................................................................... 22

Annex A (informative) Examples of hands protective equipment for thermal domestic

risks .............................................................................................................................................................. 24

Annex B (informative) Example of relevant tests to be performed depending of the field of

use of the product .................................................................................................................................... 25

Annex ZA (informative) Relationship between this European Standard and the Essential

Requirements of Regulation 2016/425 aimed to be covered ................................................. 26

Bibliography ............................................................................................................................................................ 27

---------------------- Page: 4 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
European foreword

This document (EN 407:2020) has been prepared by Technical Committee CEN/TC 162 “Protective

clothing including hand and arm protection and lifejackets”, the secretariat of which is held by DIN.

This European Standard shall be given the status of a national standard, either by publication of an

identical text or by endorsement, at the latest by October 2020, and conflicting national standards

shall be withdrawn at the latest by April 2021.

Attention is drawn to the possibility that some of the elements of this document may be the subject of

patent rights. CEN shall not be held responsible for identifying any or all such patent rights.

This document supersedes EN 407:2004.
The major changes are:
— New tests 6.2, 6.3, 6.4, 6.8;
— Mechanical strength;
— Hand protective equipment;
— New pictogram Figure 7;
— Clause 8 (information supplied by the manufacturer: revised);
— New Annex A;
— New Annex B.

This document has been prepared under a mandate given to CEN by the European Commission and

the European Free Trade Association, and supports essential requirements of EU Regulation.

For relationship with EU Regulation, see informative Annex ZA, which is an integral part of this

document.

According to the CEN-CENELEC Internal Regulations, the national standards organisations of the

following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,

Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary,

Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,

Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,

Turkey and the United Kingdom.
---------------------- Page: 5 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
Introduction

This document has been developed to cover all type of Personal Protective Equipment protecting the

hand, a part of the hand or a part of the arm against thermal risks, no matter where they are used

(professional use, consumer, domestic use…).
---------------------- Page: 6 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
1 Scope

This document specifies requirements, test methods, marking and information for protective gloves

and other hand protective equipment’s against thermal risks for professional use, consumer,

domestic use.
This document is also applicable to arm protective equipment.

It is used for all gloves and other hand protective equipment’s which protect the hands or part of the

hand against heat and/or fire in one or more of the following forms: flame, contact heat, convective

heat, radiant heat, small splashes or large quantities of molten metal.
This document is only applicable in conjunction with EN ISO 21420:2020.

This document does not apply to gloves for fire-fighters or welding that have their own standards.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content

constitutes requirements of this document. For dated references, only the edition cited applies. For

undated references, the latest edition of the referenced document (including any amendments)

applies.

EN 348:1992, Protective clothing — Test method: Determination of behaviour of materials on impact of

small splashes of molten metal

EN ISO 21420:2020, Protective gloves — General requirements and test methods (ISO 21420:2020)

EN 659:2003+A1:2008, Protective gloves for firefighters

EN ISO 6942:2002, Protective clothing — Protection against heat and fire — Method of test:

Evaluation of materials and material assemblies when exposed to a source of radiant heat (ISO 6942)

EN ISO 7500-1:2018, Metallic materials — Calibration and verification of static uniaxial testing

machines — Part 1: Tension/compression testing machines — Calibration and verification of the force-

measuring system (ISO 7500-1:2018)

EN ISO 9151:2016, Protective clothing against heat and flame — Determination of heat transmission

on exposure to flame (ISO 9151)

EN ISO 9185:2007, Protective clothing — Assessment of resistance of materials to molten metal splash

(ISO 9185)

EN ISO 12127-1:2015, Clothing for protection against heat and flame — Determination of contact heat

transmission through protective clothing or constituent materials — Part 1: Contact heat produced by

heating cylinder (ISO 12127-1)

EN ISO 15025:2016, Protective clothing — Protection against flame — Method of test for limited flame

spread (ISO 15025)
---------------------- Page: 7 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.

ISO and IEC maintain terminological databases for use in standardization at the following addresses:

— IEC Electropedia: available at http://www.electropedia.org/
— ISO Online browsing platform: available at https://www.iso.org/obp
3.1
after flame time

length of time for which a material continues to flame, under the specified test conditions, after the

ignition source has been removed
3.2
afterglow time

time for which a material continues to afterglow, under specified test conditions after cessation of

after flaming or after removal of the ignition source
3.3
back of the glove
back of hand, excluding fingers
3.4
char

formation of a carbonaceous brittle residue when material is exposed to thermal energy

[SOURCE: EN ISO 15025:2016, 3.4]
3.5
cuff

part of the glove that extends beyond the opening of glove body to cover the wrist area and

sometimes part of the forearm
3.6
debris

material separating from the specimen during the test procedure and falling from the specimen

without flaming
3.7
dripping
detachment of molten droplets during the melting process
3.8
flaming debris

material separating from the specimen during the test procedure and igniting the filter paper

3.9
hands protective equipment against thermal risks

equipment which protect hand and/or areas of the hand intended to be exposed to thermal risks

Note 1 to entry: See examples in Annex A.
---------------------- Page: 8 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
3.10
high thermal resistant gloves

gloves which claimed at least level 3 for one of the following properties: convective heat, contact

heat, radiant heat, small metal splashes, large quantities of molten metal
3.11
hole

opening, break, or discontinuity of any size in the original structure of the test specimen's material

caused by application of the test flame
3.12
melting
liquefaction of the material under the influence of heat
3.13
innermost layer
layer closest to the wearer's skin
3.14
reinforcement

additional layer which does not cover the full area where the protection is claimed

Note 1 to entry: Most of the time, this area has a limited surface to preserve comfort and dexterity of the gloves.

4 General requirements
4.1 General

Where protection against other than thermal risk is needed the specific standard shall be used.

The protective gloves according to this document shall meet all the applicable requirements of

EN ISO 21420:2020.

When parts of the glove are made from dissimilar materials, these dissimilar materials shall be tested

separately, except if another way is specified in the standard. The results of each material shall

comply with the requirements given in 4.5.

In those circumstances when the sample size is significantly larger than the particular part of the

glove or hands protective equipment being tested, then the manufacturer shall be requested to

supply samples of identical material.
4.2 Cleaning

All tests required in this document shall be performed on unused gloves or hand protective

equipment unless otherwise specified.

If care instructions are provided, the relevant tests shall be performed on the gloves or hand

protective equipment, before and after they have been subjected to the procedure described in the

care instruction, including the maximum recommended number of cleaning cycles. The levels of

performance and the mechanical strength (4.3) are given by the lowest of the 2 results obtained

before and after cleaning.

NOTE Manufacturer’s instructions typically indicate one or several of the various methods and processes

of ISO 6330, ISO 15797 or equivalent as standardized processes for cleaning.
---------------------- Page: 9 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
4.3 Mechanical strength

The glove material(s) shall be tested according to 6.8. The tear strength resistance shall have at least

a value of 10 N.
4.4 Sizes and dimensions
4.4.1 Gloves
The gloves shall correspond to the relevant requirements of EN ISO 21420:2020.

If according the intended use, the hand protector needs to be taken off quickly, the protective gloves

of performance levels 3 and 4 as specified in 4.5.2 to 4.5.7 shall be manufactured so that they can

easily be removed in case of an emergency. The test shall be performed according to

EN 659:2003+A1:2008, 3.15 using the same requirement. This property shall be justified and

explained in a warning included in the manufacturer’s information.

The removal test shall be carried out only in the dry state if the manufacturer’s information states

that the glove is not intended for use in wet conditions.

If protection against metal splashes as described in 4.5.6 and/or 4.5.7 is claimed, the minimal length

of the glove shall correspond to the requirements of Table 1.
Table 1 — Minimal length of the glove
Size of the hand 5 6 7 8 9 10 11 12 13
Minimal length of
290 300 310 320 330 340 350 360 370
glove (mm)
4.4.2 Hand protective equipment’s

Hand protective equipment’s against thermal risks shall have a sufficient dimension to fully cover the

part of the hand intended to be protected against thermal risk. The property shall be verified by

visual inspection.

The manufacturer information shall contain precise information about how to use the hand

protective equipment and which part of the hand is protected.
4.5 Thermal performances
4.5.1 General

For each of the following test methods the defined performance level depends upon the intended

field of application of the glove or hand protective equipment. Only the tests which are relevant to

the risks in the intended end-use application shall be carried out.
For the choice of relevant testing, examples are given in Annex B.
4.5.2 Limited flame spread

Using test method 6.2 the glove and other hand protective equipment, as well as all outer materials

shall correspond to the requirements of Table 2. Surface of the innermost layer of the glove shall be

inspected, it shall show no sign of melting. No hole shall appear on all layers of the tested area. The

seam shall not come apart after the ignition time.

For high thermal resistant gloves (level 3 or 4), all outer materials different to the finger area shall be

tested according to EN ISO 15025:2016, method A and comply at least with level 3 of Table 2. Seams

and outer accessories with a surface area greater than 10 cm shall also be tested.

If the outermost layer melts, the material shall not produce molten or flaming debris.

---------------------- Page: 10 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
Table 2 — Performance levels for limited flame spread
After flame
After glow time
Performance
time
level
1 ≤ 15 no requirement
2 ≤ 10 ≤ 120
3 ≤ 3 ≤ 25
4 ≤ 2 ≤ 5

After flame time is measured to the nearest second and after flame times of less than 1,0 s should be

recorded as zero.

Afterglow time is measured to the nearest second and afterglow times of less than 1,0 s should be

recorded as zero.
4.5.3 Contact heat

Using the test method 6.3 the material shall correspond to the requirements of Table 3.

Table 3 — Performance levels for contact heat test
Contact Temperature T
Threshold time t
Performance level
1 100 ≥ 15
2 250 ≥ 15
3 350 ≥ 15
4 500 ≥ 15

For contact heat performance levels of 3 or 4, the limited flame spread test according to 6.2 shall be

performed. The product shall reach at least level 3 in the limited flame spread test, otherwise the

maximum contact heat performance that shall be reported is level 2.

Innermost layers of the glove shall be inspected, it shall show no sign of melting and holing.

4.5.4 Convective heat

Using the test method 6.4 the material shall correspond to the requirements of Table 4.

Table 4 — Performance levels for convective heat
Heat transfer index HTI
Performance level
1 ≥ 4
2 ≥ 7
3 ≥ 10
4 ≥ 18
---------------------- Page: 11 ----------------------
SIST EN 407:2020
EN 407:2020 (E)

For convective heat performance levels of 3 or 4, the limited flame spread test according to 6.2 shall

be performed. The product shall reach at least level 3 in the limited flame spread test, otherwise the

maximum convective heat performance that shall be reported is level 2.

Innermost layers of the glove shall be inspected, it shall show no sign of melting and holing.

4.5.5 Radiant heat

Using the test method 6.5 the material shall correspond to the requirements of Table 5.

Table 5 — Performance levels for radiant heat
Heat transfer t
Performance level
1 ≥ 7
2 ≥ 20
3 ≥ 50
4 ≥ 95

For radiant heat performance levels of 3 or 4, the limited flame spread test according to 6.2 shall be

performed. The product shall reach at least level 3 in the limited flame spread test, otherwise the

maximum radiant heat performance that shall be reported is level 2.

Innermost layers of the glove shall be inspected, it shall show no sign of melting and holing.

4.5.6 Small splashes of molten metal

Using the test method 6.6 the number of droplets which produce a temperature rise of 40 °C, shall

correspond to the requirements of Table 6.
Table 6 — Levels of performance for the test of small splashes of molten metal
Performance level Number of droplets
1 ≥ 10
2 ≥ 15
3 ≥ 25
4 ≥ 35

For small splashes of molten metal performance levels of 3 or 4, the limited flame spread test

according to 6.2 shall be performed. The product shall reach at least level 3 in the limited flame

spread test, otherwise the maximum small splashes of molten metal performance that shall be

reported is level 2.

Outermost and innermost layers of the glove shall be inspected, it shall show no sign of melting. No

hole shall appear on innermost layer.
4.5.7 Large quantities of molten metal

Using the test method 6.7 the PVC foil skin-simulant shall not exhibit any smoothness or other

changes to the grained surface with the relevant quantities of molten iron used. See Table 7.

For large quantities of molten metal performance levels of 3 or 4, the limited flame spread test

according to 6.2 shall be performed. The product shall reach at least level 3 in the limited flame

spread test, otherwise the maximum large quantities of molten metal performance that shall be

reported is level 2.
---------------------- Page: 12 ----------------------
SIST EN 407:2020
EN 407:2020 (E)

Material and material assemblies which ignite during the test do not meet the requirement of this

test.

Table 7 — Levels of performances for the test of large quantities of molten metal

Molten iron
Performance Level
1 30
2 60
3 120
4 200

Innermost layers of the glove shall be inspected, it shall show no sign of melting and holing.

The use of molten iron is mandatory. Other optional molten materials could be tested as required

(example Aluminium, molten glass,). The corresponding test results shall be given on the information

supplied by the manufacturer (Clause 8).
5 Sampling and conditioning
Specimens shall be conditioned in the following conditioning atmosphere:
— Temperature (23 ± 2) °C and relative Humidity (50 ± 5) %

The following conditioning could be used, and shall be reported in the test report:

— Temperature (20 ± 2) °C and relative Humidity (65 ± 5) %
— The period of conditioning is at least 24 h before testing.
6 Test methods
6.1 General
6.1.1 General information

The test shall be started within 5 min after removal of the specimen from the conditioning.

For multi-layered gloves, the tests are carried out simultaneously on all layers, even if these in some

circumstances, are no longer connected. This applies to test methods described in 6.2 to 6.7.

For each of the required measurements performed in accordance with this document, a

corresponding estimate of the uncertainty of measurement should be evaluated. One of the following

approaches should be used:
— Statistical method e.g. as given in ISO 5725-2 [3];
— Mathematical method e.g. as given in ISO/IEC GUIDE 98-3 [4];
— Uncertainty and conformity assessment as given in ISO/IEC GUIDE 98-4 [5];
— JCGM-100:2008 [6].
---------------------- Page: 13 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
6.1.2 Optional additional tests

If special applications require testing in a different environment, manufacturer, in the information

supplied by the manufacturer (Clause 8), shall describe that environment, and conditioning and

testing shall be performed in that environment.
6.2 Limited flame spread
6.2.1 Specimen
For whole gloves, three specimens shall be tested.

All outer material of high thermal resistant gloves and hand protective equipment against thermal

risks shall be tested according to EN ISO 15025:2016, method A, except for 8.1.1, only three

specimens are necessary.
6.2.2 Procedure for gloves

Test method according to EN ISO 15025:2016, method B, for complete gloves with the following

modification:

The glove is mounted vertically so that the point A (Figure 1) is at the midpoint of the lower edge.

Dimensions in mm
Figure 1 — Mounting of test glove
---------------------- Page: 14 ----------------------
SIST EN 407:2020
EN 407:2020 (E)
Dimensions in mm
Key
1 metallic rod
Figure 2 — Mounting of test glove (finger simulation)

The burner is placed below the glove so that it is in a plane with the vertical middle line of the glove

or the middle finger and is perpendicular to the surface of the glove. The burner is mounted at an

angle of 30° ± 3° to the vertical. The distance between the tip of the burner and the lower edge of the

glove or the middle finger shall be 20 mm ± 2 mm.

For leather gloves and mittens, a metallic rod simulating the finger shall be inserted to ensure that

the material is in contact to the flame and limit the retraction of material during all the test time (see

Figure 2).
The rod shall be rigid. Material and dimensions have no influence on the test.

The after flame time and afterglow time shall be recorded after an ignition time of 10 s (see Table 2).

6.2.3 Test report
The test report shall contain the following information:
— reference to the clause of this document;
— the reference of the sample;

— the three single values for after flame time and afterglow time to the nearest second;

— any deviation from the test method;

— the performance level corresponds to the situation where the three single values fulfilled one

level of Table 2. (the lower test result defines the level of performance)
---------------------- Page: 15 ----------------------
SIST EN 407:2020
EN 407:2020 (E)

— report any observations of changes in the physical appearance of the material specimens

following exposure: the occurrence of melting, the occurrence of debris, the number of holes

that develop, the size of the largest hole to the nearest millimetre, the seam integrity…

6.3 Contact heat
6.3.1 Specimen

For gloves, palm area shall be tested. All other areas, different from the palm, intended to be exposed

to contact heat shall be tested (e.g. palm side of fingers area).

For hand protective equipment, all areas intended to be exposed to contact heat shall be tested.

For each tested part, three specimens taken from three different products shall be tested.

If a reinforcement is added to the tested area, then the samples taken shall be without reinforcement.

6.3.2 Procedure
The test method is according to EN ISO 12127-1:2015.
6.3.3 Test report
The test report shall contain the following information:
— reference to the clause of this document;
— the reference of the sample;
— the contact temperature T ;
— the three single values for the threshold time t to the nearest whole second;
— any deviation from the test method;

— the performance level in accordance with Table 3 based on the lowest of the single values;

— report any observations of changes in the physical appearance of the material specimens

following exposure: the number of holes that develop, the size of the largest hole to the

nearest millimetre, hardening, swelling, shrinking, melting…

The manufacturer may additionally report test results from the parts of the glove with reinforcement

in the information as described in Clause 8. The material of the reinforcement shall not melt at the

test temperature.
6.4 Convective heat
6.4.1 Specimen

The specimens shall be taken from the palm and the back of the glove if different of the palm.

If the protection is given by a multi-layered assembly, the full assembly shall be tested in the usual

order of the layers.

For each material or material assembly, three specimens shall be tested taken from three different

products.

The size of the tested specimen shall be (140 ± 5) mm × (140 ± 5) mm taken from the glove. If it is

not possible to take such a specimen from a glove then a material sample shall be used, provided it

was produced in the same way as the glove and includes any seam present.
---------------------- Page: 16 ----------------------
SIST EN 407:2020
EN 407:2020 (E)

If a reinforcement is added to the tested area, then the samples taken shall be without reinforcement.

6.4.2 Procedure

The test method is according to EN ISO 9151:2016, with modifications of specimen (6.4.1).

6.4.3 Test report
The test report shall contain the following information:
— reference to the clause of this document;
— the reference of the sample;

— the three single values for the heat transfer index HTI to the nearest whole second;

— any deviation from the test method;
— the performance level in accordance wit
...

Questions, Comments and Discussion