Transformers and inductors for use in telecommunication and electronic equipment - Main dimensions of coil formers -- Part 1: Coil formers for laminated cores

Specifies the main dimensions of coil formers for transformers and inductors, using a square stack of the laminations inserted in the coil formers.

Transformatoren und Drosseln für nachrichtentechnische und elektronische Einrichtungen - Spulenkörperhauptmaße -- Teil 1: Spulenkörper für lamellierte Kerne

Transformateurs et inductances destinés aux équipements électroniques et de télécommunication - Dimensions principales des carcasses -- Partie 1: Carcasses pour noyaux feuilletés

Spécifie les dimensions principales des carcasses pour transformateurs et inductances utilisant un empilement en carré de tôles découpées insérées dans les carcasses.

Transformers and inductors for use in telecommunication and electronic equipment - Main dimensions of coil formers - Part 1: Coil formers for laminated cores (IEC 61797-1196):

General Information

Status
Published
Publication Date
31-Aug-2002
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Sep-2002
Due Date
01-Sep-2002
Completion Date
01-Sep-2002

Buy Standard

Standard
EN 61797-1:2002
English language
26 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Transformers and inductors for use in telecommunication and electronic equipment - Main dimensions of coil formers - Part 1: Coil formers for laminated cores (IEC 61797-1196):Transformatoren und Drosseln für nachrichtentechnische und elektronische Einrichtungen - Spulenkörperhauptmaße -- Teil 1: Spulenkörper für lamellierte KerneTransformateurs et inductances destinés aux équipements électroniques et de télécommunication - Dimensions principales des carcasses -- Partie 1: Carcasses pour noyaux feuilletésTransformers and inductors for use in telecommunication and electronic equipment - Main dimensions of coil formers -- Part 1: Coil formers for laminated cores31.220.01Elektromehanske komponente (sestavni deli, gradniki) na splošnoElectromechanical components in general29.180Transformatorji. DušilkeTransformers. ReactorsICS:Ta slovenski standard je istoveten z:EN 61797-1:1996SIST EN 61797-1:2002en01-september-2002SIST EN 61797-1:2002SLOVENSKI
STANDARD



SIST EN 61797-1:2002



SIST EN 61797-1:2002



SIST EN 61797-1:2002



SIST EN 61797-1:2002



SIST EN 61797-1:2002



NORMEINTERNATIONALEINTERNATIONALSTANDARDCEIIEC1797-1Première éditionFirst edition1996-10Transformateurs et inductances destinésaux équipements électroniques etde télécommunication -Dimensions principales des carcasses -Partie 1:Carcasses pour noyaux feuilletésTransformers and inductors for use intelecommunication and electronic equipment -Main dimensions of coil formers -Part 1:Coil formers for laminated cores© CEI 1996 Droits de reproduction réservés — Copyright — all rights reservedAucune partie de cette publication ne peut être reproduite niutilisée sous quelque forme que ce soit et par aucun pro-cédé, électronique ou mécanique, y compris la photocopie etles microfilms, sans l'accord écrit de l'éditeur.No part of this publication may be reproduced or utilized inany form or by any means, electronic or mechanical,including photocopying and microfilm, without permissionin writing from the publisher.Bureau Central de la Commission Electrotechnique Internationale 3, rue de Varembé Genève, SuisseCommission Electrotechnique Internationale CODE PRIXInternational Electrotechnical Commission PRICE CODEMew ystapoaitan 3neltrpoTexHHgecnast KoMHCC tR• Pour prix, voir catalogue en vigueurFor price, see current catalogueIEC•SSIST EN 61797-1:2002



1797-1 ©IEC:1996- 3 -CONTENTSPageFOREWORD 5Clause1 Scope and object 72 Normative references
73 Laminations 74 Coil former designation
94.1 Standard version (without terminal pins) 94.2 Printed wiring board mounting version (with terminal pins) 95 Dimensions 95.1 General
95.2 Dimensions corresponding to the core stack height
116 Dimensions of coil formers for bracket mounting
136.1 Coil formers, standard version
136.1.1 Coil formers for YEI 1-types 136.1.2 Coil formers for YEx 2-types 156.1.3 Coil formers for YUI 1-types
176.1.4 Coil formers for YM 1-types 196.2 Coil formers, standard version with air duct 216.2.1 Coil formers for YEI 1-types 216.2.2 Coil formers for YUI 1-types
237 Dimensions of coil formers for printed wiring board mounting and grid plans 257.1 Level mounting style
257.1.1 Coil formers for YEI 1-types 257.1.2 Coil formers for YEx 2-types 297.1.3 Coil formers for YUI 1-types
337.1.4 Coil formers for YM 1-types 377.2 Vertical mounting style
417.2.1 Coil formers for YEx 2-types 418 Material of coil formers 459 Solderability and mechanical strength of terminal pins
45SIST EN 61797-1:2002



1797-1 © I EC:1996- 5 -INTERNATIONAL ELECTROTECHNICAL COMMISSIONTRANSFORMERS AND INDUCTORS FOR USE INTELECOMMUNICATION AND ELECTRONIC EQUIPMENT -MAIN DIMENSIONS OF COIL FORMERS -Part 1: Coil formers for laminated coresFOREWORD1)The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising allnational electrotechnical committees (IEC National Committees). The object of the IEC is to promote internationalcooperation on all questions concerning standardization in the electrical and electronic fields. To this end and inaddition to other activities, the IEC publishes International Standards. Their preparation is entrusted to technicalcommittees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work.International, governmental and non-governmental organizations liaising with the IEC also participate in thispreparation. The IEC collaborates closely with the International Organization for Standardization (ISO) in accordancewith conditions determined by agreement between the two organizations.2)The formal decisions or agreements of the IEC on technical matters express, as nearly as possible an internationalconsensus of opinion on the relevant subjects since each technical committee has representation from all interestedNational Committees.3)The documents produced have the form of recommendations for international use and are published in the form ofstandards, technical reports or guides and they are accepted by the National Committees in that sense.4)In order to promote international unification, IEC National Committees undertake to apply IEC International Standardstransparently to the maximum extent possible in their national and regional standards. Any divergence between the IECStandard and the corresponding national or regional standard shall be clearly indicated in the latter.5)The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipmentdeclared to be in conformity with one of its standards.6)Attention is drawn to the possibility that some of the elements of this International Standard may be the subject ofpatent rights. The IEC shall not be held responsible for identifying any or all such patent rights.International Standard IEC 1797-1 has been prepared by IEC technical committee 51: Magneticcomponents and ferrite materials.The text of this standard is based on the following documents:FDISReport on voting
51 /420/FDIS51/442/RVDFull information on the voting for the approval of this standard can be found in the report on votingindicated in the above table.SIST EN 61797-1:2002



1797-1 ©I EC:1996- 7 -TRANSFORMERS AND INDUCTORS FOR USEIN TELECOMMUNICATION AND ELECTRONIC EQUIPMENT -MAIN DIMENSIONS OF COIL FORMERS -Part 1: Coil formers for laminated cores1 Scope and objectThis part of IEC 1797 specifies the main dimensions of coil formers for transformers and inductors,using a square stack of the laminations inserted in the coil formers. The main dimensions arethose permitting interchangeability with respect to conformance with core sizes and outline dimen-sions of the completed components.2 Normative referencesThe following normative documents contain provisions which, through reference in this text,constitute provisions of this part of IEC 1797. At the time of publication, the editions indicated werevalid. All normative documents are subject to revision, and parties to agreements based on thispart of IEC 1797 are encouraged to investigate the possibility of applying the most recent editionsof the normative documents indicated below. Members of IEC and ISO maintain registers ofcurrently valid International Standards.IEC 68-2-20: 1979, Basic environmental testing procedures - Part 2: Tests - Test T: SolderingAmendment 2 (1987)IEC 321: 1970, Guidance for the design and use of components intended for mounting on boardswith printed wiring and printed circuitsAmendment 1 (1975)IEC 707: 1981, Methods of test for the determination of the flammability of solid electricalinsulating materials when exposed to an igniting sourceAmendment 1 (1992)IEC 740: 1982, Laminations for transformers and inductors for use in telecommunication andelectronic equipmentAmendment 1 (1991)IEC 852: Outline dimensions of transformers and inductors for use in telecommunication andelectronic equipmentISO 3: 1973, Preferred numbers - Series of preferred numbersISO 286-1: 1988, ISO system of limits and fits - Part 1: Bases of tolerances, deviations and fits3 LaminationsFor the purpose of this specification, the laminations shall conform with the dimensions of IECtypes YEI 1, YEx 2, YUI 1, YUI 2 and YM 1, as prescribed in the tables of IEC 740. YEx stands forthe types YEE, YEF, YEI, YEL and YES.SIST EN 61797-1:2002



1797-1 © IEC:1996- 9 -4 Coil former designationCoil formers shall be designated as follows:4.1 Standard version (without terminal pins)CF - IEC 1797-1 - YEI 1-50 d S AIdentification of a coil formerNumber of this standard Identification of the laminated coreIndication of standard version (without terminal pins)Indication of air duct 4.2 Printed wiring board mounting version (with terminal pins)CF - IEC 1797-1 - YEI 1-18 d Q PMIdentification of a coil formerNumber of this standard Identification of the laminated coreThis letter indicates mounting style, level mounting style (Q)or vertical mounting style (V) This letter indicates PWB mountingThis letter indicates a metric grid plan5 Dimensions5.1 GeneralTypical drawings and dimensions of coil formers are listed in this standard. The coil former designmay not correspond to the graphic representation shown in the figures, but the principaldimensions which have tolerances shall be followed and other details such as intermediateflanges, etc. may be arranged between the manufacturer and the user.All the listed dimensions in this standard are in millimetres.SIST EN 61797-1:2002



1797-1 ©IEC:1996– 11 –Tolerances of coil formers, except where indicated as maximum or minimum, shall complywith ISO 286-1. The appropriate tolerances are shown at the head of each column of the table ofdimensions. Flange thickness should be 0,4 mm minimum.Length of terminal pins depends on printed wiring board thickness of 1,5 mm or 1,6 mm.5.2 Dimensions corresponding to the core stack heightIn the associated standards on outline dimensions of transformers and inductors, IEC 852 series,a range of stack heights is specified, which allows continuous variations of power ratings, althoughthe square stack is preferred. The increment of the stack height follows the R10 series of preferrednumbers)* as a multiple of the width of that limb of the lamination which carries the total magneticflux. A suffix letter is used to designate the appropriate stack height as shown below:Suffix letter zMultiple of limb width of laminationa0,5b0,63c0,8d1,0square stacke1,25f1,6g2,0If a stack height other than the preferred square stack is used for the core, and one of the otherspecified stack heights is chosen, the dimensions of the associated coil formers in the direction ofthe stack height will differ from those given in the following tables, which apply to square stacksonly.In this case the values of dimensions c and h are obtained by increasing or decreasing the valuesin the appropriate tables by the same amount as the stack height changes.The lamination designation followed by the appropriate suffix letter shall be used to designate thecore. If two larger parts of a lamination shape are used to form a core, this shall be indicated bythe letter L to the designation (e.g. YEx 2).As defined in ISO 3.SIST EN 61797-1:2002



1797-1 © IEC:1996- 13 -6 Dimensions of coil formers for bracket mounting6.1 Coil formers, standard version6.1.1 Coil formers for YEI 1-typesIEC 820/961)Minimum wall thickness according to theappropriate standards on safety.2)Layer length depending on flange thickness.fhCbaFigure 1 - YEI 1 coil formers for bracket and U-clamp mounting,standard versionTable 1 - Dimensions of coil formers type YEI 1 - square stack for bracketand U-clamp mounting, standard versionCoil formerdesignationCFCF-IEC 1797-1-.amax.bmin.cmax.fmax.hmin.11max.YEI1-10d-S19,710,323,06,310,414,8YEI 1-13d-S25,113,330,08,313,518,9YEI 1-14d-S27,414,433,09,214,720,7YEI 1-16d-S31,416,537,010,116,823,7YEI 1-18d-S35,318,542,011,618,826,6YEI 1-20d-S39,320,547,013,021,029,4YEI 1-22d-S43,322,651,014,023,032,3YE11-25d-S49,225,658,015,826,536,8YE11-28d-S55,128,665,017,829,541,0YE11-32d-S62,432,675,020,833,547,0YE11-36d-S70,036,883,022,737,753,0YE11-40d-S78,040,893,025,741,759,0YEI 1-45d-S88,045,8105,029,246,766,5YEI 1-50d-S98,051,0116,032,052,074,0YE11-58d-S114,059,0134,037,060,086,0YEI 1-64d-S126,065,0149,041,566,095,0YE11-72d-S141,073,5167,046,374,5106,0YEI 1-80d-S157,081,5191,054,382,5118,0SIST EN 61797-1:2002



1797-1 © IEC:1996- 15 -6.1.2 Coil formers for YEx 2-typesCV•
ba/EC 821/96•hf1)Minimum wall thickness according to theappropriate standards on safety.2)Layer length depending on flange thickness.Figure 2 - YEx 2 coil formers for bracket and U-clamp mounting,standard versionTable 2 - Dimensions of coil formers type YEx 2 - square stack for bracketand U-clamp mounting, standard versionCoil formerdesignationCF-IEC 1797-1-.CFamax.bmin.cmax.fmax.hmin.11max.YEx 2- 2d-S5,52,55,51,52,55,3YEx 2-3d-S6,93,16,91,93,16,7YEx 2- 4d-S8,73,98,72,43,98,5YEx 2- 5d-S11,14,911,13,14,910,9YEx2-6d-S13,96,113,93,96,113,4YEx 2- 8d-S17,37,717,34,87,716,8YEx 2-10d-S22,29,822,26,29,821,8YEx 2-12d-S27,812,227,87,812,227,4YEE2-6dL-S13,96,113,93,96,121,4YEE 2- 8dL-S17,37,717,34,87,725,8YEE 2-10dL-S22,29,822,26,29,833,8YEE 2-12dL-S27,812,227,87,812,243,4SIST EN 61797-1:2002



•fhca!EC 822/961)Minimum wall thickness according to theappropriate standards on safety.2)Layer length depending on flange thickness.1797-1 ©IEC:1996- 17 -6.1.3 Coil formers for YUI 1-typesNOTE - Coil formers for YUI 1-types may also be used for YUI 2-types.Figure 3 - YUI 1 coil formers for bracket and pillar mounting,standard versionTable 3 - Dimensions of coil formers type YUI 1 - square stack for bracketand pillar mounting, standard versionCoil formerdesignationCF-IEC 1797 1-.CFamax.bmin.cmax.fmax.hmin.1^max. YUI1-10d-S20,010,322,05,910,329,7YUI 1-13d-S26,013,429,07,813,538,7YUI 1-16d-S31,316,537,010,116,847,7YUI 1-20d-S39,020,546,012,620,859,5YUI 1-25d-S49,025,558,015,826,574,0YUI 1-30d-S58,530,668,018,331,589,0YUI 1-34d-S66,534,877,020,536,0100,0YUI 1-38d-S74,538,885,022,540,0112,0YUI 1-44d-S85,544,897,025,546,0130,0YUI 1-50d-S97,551,0110,029,052,0148,0YUI1-56d-S109,057,0123,032,558,0166,0YUI1-60d-S117,061,5132,034,563,0178,0YUI1-70d-S137,071,5154,040,573,0208,0YUI1-80d-S156,081,5176,046,583,0237,0SIST EN 61797-1:2002



1797-1 © I EC:1996- 19 -6.1.4 Coil formers for YM1-types
c
J

.1/ --pr•
a
!EC 823/96
YM 1-12d-S only1)Minimum wall thickness according to the appropriate standards on safety.2)Layer length depending on flange thickness.Figure 4 - YM 1 coil formers for bracket mounting, standard versionTable 4 - Dimensions of coil formers type YM 1 - square stackfor bracket mounting, standard vers
...

Questions, Comments and Discussion