SIST EN 12286:2000/A1:2000
(Amendment)In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Presentation of reference measurement procedures
In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Presentation of reference measurement procedures
Migrated from Progress Sheet (TC Comment) (2000-07-10): UAP of 4 months (TC Res 3/1999) (CC/990525)
In-Vitro-Diagnostika - Messung von Größen in Proben biologischen Ursprungs - Darstellung von Referenzmeßverfahren
Dispositifs médicaux de diagnostic in vitro - Mesure des grandeurs dans des échantillons d'origine biologique - Présentation des modes opératoires de mesure de référence
Diagnostični medicinski pripomočki in vitro - Merjenje količin v vzorcih biološkega izvora - Predstavitev referenčnih merilnih postopkov
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 12286:2000/A1:2000
01-november-2000
'LDJQRVWLþQLPHGLFLQVNLSULSRPRþNLLQYLWUR0HUMHQMHNROLþLQYY]RUFLKELRORãNHJD
L]YRUD3UHGVWDYLWHYUHIHUHQþQLKPHULOQLKSRVWRSNRY
In vitro diagnostic medical devices - Measurement of quantities in samples of biological
origin - Presentation of reference measurement procedures
In-Vitro-Diagnostika - Messung von Größen in Proben biologischen Ursprungs -
Darstellung von Referenzmeßverfahren
Dispositifs médicaux de d
...
This May Also Interest You
This document provides requirements and recommendations for the design, development, verification, validation and implementation of analytical tests for detecting the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using nucleic acid amplification. It addresses pre-examination, examination and post-examination process steps for human specimens.
This document is applicable to medical laboratories. It is also intended to be used by in vitro diagnostic developers and manufacturers, as well as by institutions and organizations supporting SARS-CoV-2 research and diagnostics.
This document does not apply to environmental samples.
- Technical specification53 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft50 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements and gives recommendations on the handling, storage, processing and documentation of body fluids specimens intended for human cfDNA examination during the pre-examination phase before a molecular examination is performed.
This document is applicable to molecular in vitro diagnostic examinations performed by medical laboratories. It is also intended to be used by health institutions including facilities collecting and handling specimen, laboratory customers, in vitro diagnostics developers and manufacturers, biobanks, institutions and commercial organizations performing biomedical research, and regulatory authorities.
Dedicated measures that need to be taken for cytohistological analysis of body fluid derived nucleated cells are not described in this technical specification. Neither are measures for preserving and handling of pathogens, and other bacterial or whole microbiome DNA in body fluids described.
Different dedicated measures need to be taken for preserving ccfDNA from other body fluids such as blood, lymph and others. These are not described in this document. ccfDNA from blood is covered in EN ISO 20186 3.
NOTE International, national or regional regulations or requirements can also apply to specific topics covered in this document.
- Technical specification24 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft23 pagesEnglish languagesale 10% offe-Library read for×1 day
This document gives guidelines on the handling, storage, processing and documentation of venous whole blood specimens intended for circulating cell free RNA (ccfRNA) examinations during the pre-examination phase before a molecular examination is performed. This document covers specimens collected in venous whole blood collection tubes.
The pre-examination process described in this document results in circulating cell free RNA isolated from blood plasma without prior enrichment of exosomes and other extracellular vesicles.
This document is applicable to molecular in vitro diagnostic examinations performed by medical laboratories. It is also intended to be used by laboratory customers, in vitro diagnostics developers and manufacturers, biobanks, institutions and commercial organizations performing biomedical research, and regulatory authorities.
Different dedicated measures are taken during the pre-examination phase for isolated RNA from enriched exosomes and other extracellular vesicles enriched from venous whole blood and for cellular RNA isolated from venous whole blood. These are not described in this document but are covered in CEN/PWI, Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for exosomes and other extracellular vesicles in venous whole blood — Isolated DNA, RNA and proteins, and in ISO 20186-1, Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for venous whole blood — Part 1: Isolated cellular RNA.
NOTE International, national or regional regulations or requirements can also apply to specific topics covered in this document.
- Technical specification25 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft25 pagesEnglish languagesale 10% offe-Library read for×1 day
This document gives guidelines on the handling, storage, processing and documentation of venous whole blood specimens intended for DNA, RNA and protein examination from exosomes and other extracellular vesiclesduring the pre-examination phase before a molecular examination is performed. This document covers specimens collected in venous
whole blood collection tubes.
The pre-examination process described in this document results in isolated DNA, RNA and proteins from enriched exosomes and other extracellular vesicles.
This document is applicable to molecular in vitro diagnostic examinations performed by medical laboratories. It is also intended to be used by laboratory customers, in vitro diagnostics developers and manufacturers, biobanks, institutions and commercial organizations performing biomedical research, and regulatory authorities.
Different dedicated measures are taken during the pre-examination phase for venous whole blood circulating cell-free RNA (ccfRNA) examination and for venous whole blood circulating cell-free DNA (ccfDNA) examination, both without prior enrichment of exosomes and other extracellular vesicles. These are not described in this document but are covered in prEN ISO 20186-3, Molecular in-vitro diagnostic examinations — Specifications for pre-examination processes for venous whole blood — Part 3: Isolated circulating cell free DNA from plasma and CEN/PWI, Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for venous whole blood — Isolated circulating cell free RNA from plasma.
NOTE International, national or regional regulations or requirements can also apply to specific topics covered in this document.
- Technical specification30 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft30 pagesEnglish languagesale 10% offe-Library read for×1 day
This document establishes acceptable performance criteria for antimicrobial susceptibility test
(AST) devices that are used to determine minimum inhibitory concentrations (MIC) of bacteria to
antimicrobial agents in medical laboratories.
This document specifies requirements for AST devices and procedures for assessing performance of
such devices. It defines how a performance evaluation of an AST device is to be conducted.
This document has been developed to guide manufacturers in the conduct of performance evaluation
studies.
- Standard25 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft23 pagesEnglish languagesale 10% offe-Library read for×1 day
This document gives guidelines on the handling, documentation, storage and processing of fine needle aspirates (FNAs) intended for RNA examination during the pre-examination phase before a molecular examination is performed.
This document is applicable to molecular in vitro diagnostic examination including laboratory developed tests performed by medical laboratories and molecular pathology laboratories that examine RNA isolated from FNAs. It is also intended to be used by laboratory customers, in vitro diagnostics developers and manufacturers, biobanks, institutions and commercial organisations performing biomedical research, and regulatory authorities.
Different dedicated measures are taken for collecting, stabilizing, transporting and storing of core needle biopsies (FNA B) and are not covered in this document, but in ISO 20184-1, Molecular in vitro diagnostic examinations – Specifications for pre-examination processes for frozen tissue – Part 1: Isolated RNA and ISO 20166-1, Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for formalin fixed and paraffin-embedded (FFPE) tissue — Part 1: Isolated RNA.
RNA in pathogens present in FNA is not covered by this document.
NOTE International, national or regional regulations or requirements can also apply to specific topics covered in this document.
- Technical specification38 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft38 pagesEnglish languagesale 10% offe-Library read for×1 day
This document gives guidelines on the handling, documentation, storage and processing of fine needle aspirates (FNAs) intended for protein examination during the pre-examination phase before a molecular examination is performed.
This document is applicable to molecular in vitro diagnostic examinations including laboratory developed tests performed by medical laboratories and molecular pathology laboratories that examine proteins isolated from FNAs. It is also intended to be used by laboratory customers, in vitro diagnostics developers and manufacturers, biobanks, institutions and commercial organisations performing biomedical research, and regulatory authorities.
Different dedicated measures are taken for collecting, stabilizing, transporting and storing of core needle biopsies (FNA Biopsy or FNA B) and are not covered in this document, but in EN ISO 20184 2, Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for frozen tissue — Part 2: Isolated proteins and EN ISO 20166 2, Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for formalin fixed and paraffin-embedded (FFPE) tissue — Part 2: Isolated proteins.
This document is not applicable for protein examination by immunohistochemistry.
NOTE International, national or regional regulations or requirements can also apply to specific topics covered in this document.
- Technical specification26 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft26 pagesEnglish languagesale 10% offe-Library read for×1 day
This document gives guidelines on the handling, documentation, storage and processing of fine needle aspirates (FNAs) intended for gDNA examination during the pre-examination phase before a molecular examination is performed.
This document is applicable to molecular in vitro diagnostic examinations including laboratory developed tests performed by medical laboratories and molecular pathology laboratories that examine gDNA isolated from FNAs. It is also intended to be used by laboratory customers, in vitro diagnostics developers and manufacturers, biobanks, institutions and commercial organisations performing biomedical research, and regulatory authorities.
Different dedicated measures are taken for collecting, stabilizing, transporting and storing of core needle biopsies (FNA Biopsy or FNA B) and are not covered in this document, but EN ISO 20184 3, Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for frozen tissue — Part 3: Isolated DNA and EN ISO 20166 3, Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for formalin-fixed and paraffin-embedded (FFPE) tissue — Part 3: Isolated DNA.
This document is not applicable for pathogen DNA examination and gDNA examination by in situ detection.
NOTE International, national or regional regulations or requirements can also apply to specific topics covered in this document.
- Technical specification36 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft36 pagesEnglish languagesale 10% offe-Library read for×1 day
This document gives requirements on the handling, storage, processing and documentation of saliva specimens intended for human DNA examination during the pre-examination phase before a molecular examination is performed.
This document is applicable to molecular in vitro diagnostic examination including laboratory developed tests performed by medical laboratories. It is also intended to be used by laboratory customers, in vitro diagnostics developers and manufacturers, biobanks, institutions and commercial organisations performing biomedical research, and regulatory authorities.
Dedicated measures that need to be taken for saliva collected on absorbing materiasl or by mouth washes are not described in this document. Neither are measures for preserving and handling of native saliva cell-free DNA, pathogens, and other bacterial or whole microbiome DNA in saliva described.
NOTE International, national or regional regulations or requirements can also apply to specific topics covered in this document.
- Standard21 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft16 pagesEnglish languagesale 10% offe-Library read for×1 day
This document describes a method for testing the susceptibility to antifungal agents of yeasts, including
Candida spp. and Cryptococcus neoformans, that cause infections. The reference method described here
has not been used in studies of the yeast forms of dimorphic fungi, such as Blastomyces dermatitidis
and/or Histoplasma capsulatum variety capsulatum. Moreover, testing filamentous fungi (moulds)
introduces several additional problems in standardization not addressed by the current procedure.
Those methods are beyond the scope of this document.
This document describes the broth micro-dilution reference method, which can be implemented by
either of two pathways. One pathway involves visual determination of MICs (CLSI method)[1][5]
; the
second pathway involves spectrophotometric determination of MICs (EUCAST method)[2][10]. The MIC
reflects the activity of the drug under the described test conditions and can be interpreted for clinical
management purposes by taking into account other factors, such as drug pharmacology or antifungal
resistance mechanisms. In addition, MIC distributions can be used to define wild type or non-wild
type fungal populations. Clinical interpretation of the MIC value is beyond the scope of this document;
interpretive category breakpoints specific to the CLSI- and EUCAST-derived methods can be found by
consulting the latest interpretive tables provided by the organizations[5][15]. Routine susceptibility
testing methods or diagnostic test devices can be compared with this reference method in order to
ensure comparable and reliable results for validation or registration purposes.
- Standard25 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft22 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.