Field device tool interface specification -- Part 509: Communication implementation for common object model - IEC 61784 CPF 9

IEC/TR 62453-509, which is a technical report, provides information for integrating the HART®1 technology into the FDT interface specification (IEC 62453-2). This part of IEC 62453 specifies communication and other services. This specification neither contains the FDT specification nor modifies it.

Field Device Tool (FDT)-Schnittstellenspezifikation - Teil 509: Kommunikationsimplementierung mit dem allgemeinen Objektmodell (COM) - IEC 61784 Kommunikationsprofilfamilie (CPF) 9

Spécification des interfaces des outils des dispositifs de terrain (FDT) - Partie 509: Implémentation des communications pour le modèle objet commun - CEI 61784 CPF 9

Specifikacija vmesnika orodja procesne naprave - 509. del: Implementacija komunikacije za skupni model objekta - IEC 61784 CPF 9 (IEC/TR 62453-509:2009)

IEC/TR 62453-509, ki je tehnično poročilo, zagotavlja informacije za integriranje tehnologije HART®1 v vmesniške specifikacije FDT (IEC 62453-2). Ta del IEC 62453 določa komunikacijske in ostale storitve. Ta specifikacija ne vsebuje FDT specifikacije niti je ne spreminja.

General Information

Status
Published
Publication Date
18-Jan-2010
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
26-Nov-2009
Due Date
31-Jan-2010
Completion Date
19-Jan-2010

Buy Standard

Technical report
SIST-TP CLC/TR 62453-509:2010 - BARVE v IEC standardu: stran 5
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST-TP CLC/TR 62453-509:2010
01-februar-2010
Specifikacija vmesnika orodja procesne naprave - 509. del: Implementacija
komunikacije za skupni model objekta - IEC 61784 CPF 9 (IEC/TR 62453-509:2009)

Field device tool interface specification -- Part 509: Communication implementation for

common object model - IEC 61784 CPF 9
Field Device Tool (FDT)-Schnittstellenspezifikation - Teil 509:
Kommunikationsimplementierung mit dem allgemeinen Objektmodell (COM) - IEC 61784
Kommunikationsprofilfamilie (CPF) 9
Ta slovenski standard je istoveten z: CLC/TR 62453-509:2009
ICS:
25.040.40 Merjenje in krmiljenje Industrial process
industrijskih postopkov measurement and control
35.240.50 Uporabniške rešitve IT v IT applications in industry
industriji
SIST-TP CLC/TR 62453-509:2010 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST-TP CLC/TR 62453-509:2010
---------------------- Page: 2 ----------------------
SIST-TP CLC/TR 62453-509:2010
TECHNICAL REPORT
CLC/TR 62453-509
RAPPORT TECHNIQUE
November 2009
TECHNISCHER BERICHT
ICS 25.040.40; 35.100.05; 35.110
English version
Field device tool (FDT) interface specification -
Part 509: Communication implementation for common object model -
IEC 61784 CPF 9
(IEC/TR 62453-509:2009)
Spécification des interfaces des outils Field Device Tool (FDT)-
des dispositifs de terrain (FDT) - Schnittstellenspezifikation -
Partie 509: Implémentation Teil 509: Kommunikationsimplementierung
des communications mit dem allgemeinen Objektmodell (COM) -
pour le modèle objet commun - Kommunikationsprofilfamilie (CPF) 9
CEI 61784 CPF 9 nach IEC 61784
(CEI/TR 62453-509:2009) (IEC/TR 62453-509:2009)
This Technical Report was approved by CENELEC on 2009-10-01.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the

Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,

Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,

Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: Avenue Marnix 17, B - 1000 Brussels

© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. CLC/TR 62453-509:2009 E
---------------------- Page: 3 ----------------------
SIST-TP CLC/TR 62453-509:2010
CLC/TR 62453-509:2009 - 2 -
Foreword

The text of document 65E/70/CDV, future edition 1 of IEC/TR 62453-509, prepared by SC 65E, Devices

and integration in enterprise systems, of IEC TC 65, Industrial-process measurement, control and

automation, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as

CLC/TR 62453-509 on 2009-10-01.
This standard is to be used in conjunction with EN 62453-3xy series.
Annex ZA has been added by CENELEC.
__________
Endorsement notice

The text of the Technical Report IEC/TR 62453-509:2009 was approved by CENELEC as a Technical

Report without any modification.

In the official version, for Bibliography, the following note has to be added for the standard indicated:

IEC 61784-1 NOTE Harmonized as EN 61784-1:2008 (not modified).
__________
---------------------- Page: 4 ----------------------
SIST-TP CLC/TR 62453-509:2010
- 3 - CLC/TR 62453-509:2009
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.

NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD

applies.
Publication Year Title EN/HD Year
IEC 62453-1 2009 Field device tool (FDT) interface EN 62453-1 2009
specification -
Part 1: Overview and guidance
IEC 62453-2 2009 Field device tool (FDT) interface EN 62453-2 2009
specification -
Part 2: Concepts and detailed description
IEC/TR 62453-41 2009 Field device tool (FDT) interface CLC/TR 62453-41 2009
specification -
Part 41: Object model integration profile -
Common object model

IEC 62453-309 2009 Field device tool interface specification - EN 62453-309 2009

Part 309: Communication profile integration -
IEC 61784 CPF 9
__________
---------------------- Page: 5 ----------------------
SIST-TP CLC/TR 62453-509:2010
---------------------- Page: 6 ----------------------
SIST-TP CLC/TR 62453-509:2010
IEC/TR 62453-509
Edition 1.0 2009-08
TECHNICAL
REPORT
colour
inside
Field device tool (FDT) interface specification –
Part 509: Communication implementation for common object model – IEC 61784
CPF 9
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
ICS 25.040.40; 35.100.05; 35.110 ISBN 2-8318-1058-1
® Registered trademark of the International Electrotechnical Commission
---------------------- Page: 7 ----------------------
SIST-TP CLC/TR 62453-509:2010
– 2 – TR 62453-509 © IEC:2009(E)
CONTENTS

FOREWORD...........................................................................................................................3

INTRODUCTION.....................................................................................................................5

1 Scope...............................................................................................................................6

2 Normative references .......................................................................................................6

3 Terms, definitions, symbols, abbreviated terms and conventions ......................................6

3.1 Terms and definitions ..............................................................................................6

3.2 Symbols and abbreviated terms...............................................................................6

3.3 Conventions ............................................................................................................7

3.3.1 Data type names and references to data types ............................................7

3.3.2 Vocabulary for requirements........................................................................7

4 Bus category ....................................................................................................................7

5 Access to instance and device data..................................................................................7

6 Protocol specific usage of general data types ...................................................................7

7 Protocol specific common data types................................................................................8

8 Network management data types......................................................................................8

8.1 General ...................................................................................................................8

8.2 HART device address..............................................................................................8

9 Communication data types – FDTHARTCommunicationSchema .......................................8

10 Channel parameter data types – FDTHARTChannelParameterSchema ..........................11

11 Device identification .......................................................................................................14

11.1 Device type identification data types – FDTHARTIdentSchema .............................14

11.2 Topology scan data types – DTMHARTDeviceSchema ..........................................14

11.3 Scan identification data types – FDTHARTScanIdentSchema................................15

11.4 Device type identification data types – FDTHARTDeviceIdentSchema...................16

11.5 XSLT Transformation ............................................................................................17

Bibliography..........................................................................................................................24

Figure 1 – Part 509 of the IEC 62453 series ...........................................................................5

Table 1 – Protocol specific usage of general data types..........................................................7

---------------------- Page: 8 ----------------------
SIST-TP CLC/TR 62453-509:2010
TR 62453-509 © IEC:2009(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIELD DEVICE TOOL (FDT) INTERFACE SPECIFICATION –
Part 509: Communication implementation for common object model –
IEC 61784 CPF 9
FOREWORD

1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

all national electrotechnical committees (IEC National Committees). The object of IEC is to promote

international co-operation on all questions concerning standardization in the electrical and electronic fields. To

this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,

Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC

Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested

in the subject dealt with may participate in this preparatory work. International, governmental and non-

governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely

with the International Organization for Standardization (ISO) in accordance with conditions determined by

agreement between the two organizations.

2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international

consensus of opinion on the relevant subjects since each technical committee has representation from all

interested IEC National Committees.

3) IEC Publications have the form of recommendations for international use and are accepted by IEC National

Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any

misinterpretation by any end user.

4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications

transparently to the maximum extent possible in their national and regional publications. Any divergence

between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in

the latter.

5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any

equipment declared to be in conformity with an IEC Publication.

6) All users should ensure that they have the latest edition of this publication.

7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and

members of its technical committees and IEC National Committees for any personal injury, property damage or

other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and

expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC

Publications.

8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is

indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of

patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

The main task of IEC technical committees is to prepare International Standards. However, a

technical committee may propose the publication of a technical report when it has collected

data of a different kind from that which is normally published as an International Standard, for

example "state of the art".

IEC/TR 62453-509, which is a technical report, has been prepared by subcommittee 65E:

Devices and integration in enterprise systems, of IEC technical committee 65: Industrial-

process measurement, control and automation:

This part, in conjunction with the other parts of the first edition of the IEC 62453 series

cancels and replaces IEC/PAS 62453-1, IEC/PAS 62453-2, IEC/PAS 62453-3, IEC/PAS

62453-4 and IEC/PAS 62453-5 published in 2006, and constitutes a technical revision.

Each part of the IEC/TR 62453-5xy series is intended to be read in conjunction with its

corresponding part in the IEC 62453-3xy series.
---------------------- Page: 9 ----------------------
SIST-TP CLC/TR 62453-509:2010
– 4 – TR 62453-509 © IEC:2009(E)
The text of this technical report is based on the following documents:
Enquiry draft Report on voting
65E/70/DTR 65E/119/RVC

Full information on the voting for the approval of this technical report can be found in the

report on voting indicated in the above table.

This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

The list of all parts of the IEC 62453 series, under the general title Field Device Tool (FDT)

interface specification, can be found on the IEC website.

The committee has decided that the contents of this publication will remain unchanged until

the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in

the data related to the specific publication. At this date, the publication will be

• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.

IMPORTANT – The “colour inside” logo on the cover page of this publication indicates

that it contains colours which are considered to be useful for the correct understanding

of its contents. Users should therefore print this publication using a colour printer.

---------------------- Page: 10 ----------------------
SIST-TP CLC/TR 62453-509:2010
TR 62453-509 © IEC:2009(E) – 5 –
INTRODUCTION

This part of IEC 62453 is an interface specification for developers of FDT (Field Device Tool)

components for function control and data access within a client/server architecture. The

specification is a result of an analysis and design process to develop standard interfaces to

facilitate the development of servers and clients by multiple vendors that need to interoperate

seamlessly.

With the integration of fieldbusses into control systems, there are a few other tasks which

need to be performed. In addition to fieldbus- and device-specific tools, there is a need to

integrate these tools into higher-level system-wide planning- or engineering tools. In

particular, for use in extensive and heterogeneous control systems, typically in the area of the

process industry, the unambiguous definition of engineering interfaces that are easy to use for

all those involved is of great importance.

A device-specific software component, called DTM (Device Type Manager), is supplied by the

field device manufacturer with its device. The DTM is integrated into engineering tools via the

FDT interfaces defined in this specification. The approach to integration is in general open for

all kind of fieldbusses and thus meets the requirements for integrating different kinds of

devices into heterogeneous control systems.

Figure 1 shows how IEC/TR 62453-509 is aligned in the structure of IEC 62453 series.

Part 509
Communication
implementation
for common
object model –
IEC 61784 CPF 9
Figure 1 – Part 509 of the IEC 62453 series
---------------------- Page: 11 ----------------------
SIST-TP CLC/TR 62453-509:2010
– 6 – TR 62453-509 © IEC:2009(E)
FIELD DEVICE TOOL (FDT) INTERFACE SPECIFICATION –
Part 509: Communication implementation for common object model –
IEC 61784 CPF 9
1 Scope

IEC/TR 62453-509, which is a technical report, provides information for integrating the

HART® technology into the FDT interface specification (IEC 62453-2).
This part of IEC 62453 specifies communication and other services.
This specification neither contains the FDT specification nor modifies it.
2 Normative references

The following referenced documents are indispensable for the application of this specification.

For dated references, only the edition cited applies. For undated references, the latest edition

of the referenced document (including any amendments) applies

IEC 62453-1:2009, Field Device Tool (FDT) interface specification – Part 1: Overview and

guidance

IEC 62453-2:2009, Field Device Tool (FDT) interface specification – Part 2: Concepts and

detailed description

IEC/TR 62453-41:2009, Field Device Tool (FDT) interface specification – Part 41: Object

model integration profile – Common object model
IEC 62453-309:2009, Field Device Tool (FDT) interface specification – Part 309:
Communication profile integration – IEC 61784 CPF 9
3 Terms, definitions, symbols, abbreviated terms and conventions
3.1 Terms and definitions

For the purpose of this document, the terms and definitions given in IEC 62453-1,

IEC 62453-2, and IEC/TR 62453-41 apply.
3.2 Symbols and abbreviated terms

For the purpose of this document, the symbols and abbreviations given in IEC 62453-1,

IEC 62453-2, and IEC/TR 62453-41 apply.
———————

HART ® is the trade name of the product supplied by HART Communication Foundation. This information is

given for convenience of users of this document and does not constitute an endorsement by IEC of the product

named. Equivalent products may be used if they can be shown to lead to the same results.

---------------------- Page: 12 ----------------------
SIST-TP CLC/TR 62453-509:2010
TR 62453-509 © IEC:2009(E) – 7 –
3.3 Conventions
3.3.1 Data type names and references to data types

The conventions for naming and referencing of data types are explained in IEC 62453-2

Clause A.1
3.3.2 Vocabulary for requirements
The following expressions are used when specifying requirements.
Usage of “shall” or “Mandatory” No exceptions allowed.

Usage of “should” or “Recommended” Strong recommendation. It may make sense in special

exceptional cases to differ from the described behaviour.

Usage of “can’ or “Optional’ Function or behaviour may be provided, depending on

defined conditions.
4 Bus category

IEC 61784 CPF 9 protocol is identified in the attribute busCategory of the BusCategory

element by the identifiers, as specified in IEC 62453-309.
5 Access to instance and device data
Used at methods:
• IDtmParameter::GetParameters()
• IDtmParameter::SetParameters()

These methods shall provide access to at least to all parameters defined in IEC 62453-309.

6 Protocol specific usage of general data types
Table 1 shows how general data types are used with IEC 61784 CPF 9 devices.
Table 1 – Protocol specific usage of general data types
Attribute Description for use

fdt:address All these attributes of the FDTDatatype schema are used as defined in

IEC 62453-309.
fdt:protocolId
fdt:deviceTypeId
fdt:deviceTypeInformation
fdt:deviceTypeInformationPath
fdt:manufacturerId
fdt:semanticId
fdt:applicationDomain
fdt:tag
---------------------- Page: 13 ----------------------
SIST-TP CLC/TR 62453-509:2010
– 8 – TR 62453-509 © IEC:2009(E)
7 Protocol specific common data types

This clause specifies the protocol specific common data types, which are used in the

definition of other data types.
The data types described in this clause are defined for following namespace:
Namespace:
8 Network management data types
8.1 General
The data types specified in this clause are used at following methods:
• IDtmParameter:GetParameters
• IDtmParameter:SetParameters
8.2 HART device address

The element (defined in IEC/TR 62453-41) is used for

defining the network address of a device.
9 Communication data types – FDTHARTCommunicationSchema

The data types specified in this clause are used with the methods of IFdtCommunication.

The definition of the attribute follows the data type definition as defined in IEC 62453-309.

xmlns:dt="urn:schemas-microsoft-com:datatypes" xmlns:fdt="x-schema:FDTDataTypesSchema.xml">
































---------------------- Page: 14 ----------------------
SIST-TP CLC/TR 62453-509:2010
TR 62453-509 © IEC:2009(E) – 9 –






































































---------------------- Page: 15 ----------------------
SIST-TP CLC/TR 62453-509:2010
– 10 – TR 62453-509 © IEC:2009(E)











































Example:

schemaVersion="1.21">




schemaVersion="1.21">








Examples for IEC 61784 CPF 9 burst mode
The request from the DeviceDTM:
---------------------- Page: 16 ----------------------
SIST-TP CLC/TR 62453-509:2010
TR 62453-509 © IEC:2009(E) – 11 –



Answer if the device is already in burst mode:

burstModeDetected="1" />

Receiving a burst frame:




...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.