This European Standard specifies a method for measuring the dimensional stability (i.e. the shrinkage and expansion movement) due to changes in the moisture content of hydraulic mortars or concretes (CC) or polymer hydraulic cement mortars or concretes (PCC) as defined in EN 1504-1. Two methods are proposed, namely a procedure for unrestrained movement and a procedure for restrained movement.
The provisions of the standard are applicable to grout, mortar or concrete products or systems with a maximum aggregate size of 10 mm.
Produkte und Systeme für den Schutz und die Instandsetzung von Betontragwerken - Prüfverfahren - Teil 4: Bestimmung des Schwindens und Quellens
Diese Europäische Norm ist Teil einer Reihe von Normen über Produkte und Systeme für den Schutz und die Instandsetzung von Betontragwerken. Diese Europäische Norm beschreibt ein Verfahren zur Messung der Maßbeständigkeit (d.h. des Schindens und Quellens) aufgrund von Änderungen des Feuchtegehalts von Produkten und Systemen für die Instandsetzung mit HC-, PCC-, und PC-Bindemitteln nach EN 1504-1.
Produits et systemes de protection et de réparation des structures en béton - Méthodes d'essai - Partie 4: Détermination du retrait et de l'expansion
La présente Norme européenne décrit une méthode de mesure de la stabilité dimensionnelle (expansion / retrait) résultant des variations de teneur en eau des mortiers hydrauliques ou bétons hydrauliques (CC), ou des mortiers ou bétons de ciment hydrauliques polymeres (PCC) tels que définis dans l'EN 1504-1. Deux méthodes sont proposées : un mode opératoire pour le mouvement libre et un mode opératoire pour le mouvement empeché.
La présente Norme européenne s'applique aux coulis, mortiers, ou aux produits ou systemes pour béton dont la taille des granulats ne dépasse pas 10 mm.
Proizvodi in sistemi za zaščito in popravilo betonskih konstrukcij - Preskusne metode - 4. del: Določevanje krčenja in nabrekanja
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Produkte und Systeme für den Schutz und die Instandsetzung von Betontragwerken - Prüfverfahren - Teil 4: Bestimmung des Schwindens und QuellensProduits et systemes de protection et de réparation des structures en béton - Méthodes d'essai - Partie 4: Détermination du retrait et de l'expansionProducts and systems for the protection and repair of concrete structures - Test methods - Part 4: Determination of shrinkage and expansion91.100.10Cement. Mavec. Apno. MaltaCement. Gypsum. Lime. Mortar91.080.40Betonske konstrukcijeConcrete structuresICS:Ta slovenski standard je istoveten z:EN 12617-4:2002SIST EN 12617-4:2002en01-november-2002SIST EN 12617-4:2002SLOVENSKI
STANDARD
SIST EN 12617-4:2002
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 12617-4May 2002ICS 91.080.40English versionProducts and systems for the protection and repair of concretestructures - Test methods - Part 4: Determination of shrinkageand expansionProduits et systèmes de protection et de réparation desstructures en béton - Méthodes d'essai - Partie 4:Détermination du retrait et du gonflementProdukte und Systeme für den Schutz und dieInstandsetzung von Betontragwerken - Prüfverfahren - Teil4: Bestimmung des Schwindens und QuellensThis European Standard was approved by CEN on 4 January 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2002 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12617-4:2002 ESIST EN 12617-4:2002
EN 12617-4:2002 (E)2ContentspageForeword.31Scope.42Normative references.43Terms and definitions and symbols.43.1Terms and definitions.43.2Symbols.44Principle.55Apparatus.55.1Unrestrained movement mould.55.2Measurement studs.55.3Measuring apparatus.55.4Calibration rod.55.5Tampers.65.6Concrete slab test panels.65.7Standard laboratory climate.65.8Mortar mixer.65.9Compaction tools and equipment.65.10Water baths.65.11Triangular support grid.66Procedure for unrestrained movement.66.1General.66.2Preparation of specimens.66.3Initial measurement.76.4Storage conditions.86.5Subsequent readings.86.6Calculation.96.7Recommended additional test.97Procedure for restrained movement.97.1General.97.2Preparation of specimens.97.3Storage Conditions.107.4Inspection and testing.108Test report.10Annex A (normative)
Summary of temperatures and humidities for the curing, conditioning andtesting of repair products and systems.13Bibliography.14SIST EN 12617-4:2002
EN 12617-4:2002 (E)3ForewordThis document EN 12617-4:2002 has been prepared by Technical Committee CEN/TC 104 "Concrete and relatedproducts", the secretariat of which is held by DIN.This European Standard shall be given the status of a national standard, either by publication of an identical text orby endorsement, at the latest by November 2002, and conflicting national standards shall be withdrawn at the latestby December 2002.It was prepared by sub-committee 8 "Products and systems for the protection and repair of concrete structures",the secretariat of which is held by AFNOR.This European Standard is one of a series dealing with products and systems for the protection and repair ofconcrete structures.This European Standard describes two methods for determining the dimensional stability of repair products andsystems subject to conditions of drying and immersion. The first method measures the unrestrained shrinkage andexpansion, while the second method measures the effects of restraint on the unrestrained shrinkage andexpansion.It is one of a series of inter-related parts dealing with dimensional stability of repair products and systems. Theother parts are:prEN 12617-1, Products and systems for the protection and repair of concrete structures - Test methods – Part 1:Determination of linear shrinkage.prEN 12617-2, Products and systems for the protection and repair of concrete structures - Test methods – Part 2:Determination of volumetric shrinkage.EN 12617-3, Products and systems for the protection and repair of concrete structures - Test methods - Part 3:Determination of early age linear shrinkage for structural bonding agents.Annex A is normative.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain,Sweden, Switzerland and the United Kingdom.SIST EN 12617-4:2002
EN 12617-4:2002 (E)41 ScopeThis European Standard specifies a method for measuring the dimensional stability (i.e. the shrinkage andexpansion movement) due to changes in the moisture content of hydraulic mortars or concretes (CC) or polymerhydraulic cement mortars or concretes (PCC) as defined in EN 1504-1. Two methods are proposed, namely aprocedure for unrestrained movement and a procedure for restrained movement.The provisions of the standard are applicable to grout, mortar or concrete products or systems with a maximumaggregate size of 10 mm.2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text, and the publications are listed hereafter. Fordated references, subsequent amendments to or revisions of any of these publications apply to this EuropeanStandard only when incorporated in it by amendment or revision. For undated references the latest edition of thepublication referred to applies (including amendments).EN 196-1:1994, Methods of testing cement - Part 1: Determination of strength.EN 1015-2, Methods of test for mortar for masonry – Part 2: Bulk sampling of mortars and preparation of testmortars.EN 1504-1, Products and systems for the protection and repair of concrete structures – Definitions, requirements,quality control and evaluation of conformity- Part 1: Definitions.prEN 1504-31, Products and systems for the protection and repair of concrete structures - Part 3: Structural andnon-structural repair.EN 1542, Products and systems for the protection and repair of concrete structures - Test methods - Measurementof bond strength by pull-off.EN 1766, Products and systems for the protection and repair of concrete structures - Test Methods - Referenceconcretes for testing.ISO 554, Standard atmospheres for conditioning and/or testing – Specifications.3 Terms and definitions and symbols3.1 Terms and definitionsFor the purposes of this European Standard, the terms and definitions given in EN 1504-1 apply.3.2 SymbolsThe following list of symbols is used in this standard.cis the specific length variation, in % ;mis the specific mass change, in % ;Lis the initial length of test specimen at time of release from mould, in mm ;
1 Under preparation.SIST EN 12617-4:2002
EN 12617-4:2002 (E)5Lgis the gauge length (Lg = L only for type 2 studs), in mm ;L0is the initial reading in the measuring apparatus, taken after 24 h, in mm ;DLis the length variation in relation to the initial length, in mm ;Mois the initial mass of the test specimen at time of release from the mould, in g ;DMis the mass variation in relation to the initial mass, in g.4 PrincipleThe shrinkage or expansion determination comprises two methods of test for CC and PCC repair products andsystems.The first method is for measuring the unrestrained linear movement arising from immersion in water (expansion) ordrying conditions (shrinkage) of prismatic specimens 40 mm ´ 40 mm ´ 160 mm in size from 24 h to 56 days aftercasting.The second method is for measuring the loss of adhesion and the tendency to crack, when applied to a300 mm ´ 300 mm ´ 100 mm reference concrete substrate and subjected to immersion in water (expansion) ordrying conditions (shrinkage).5 Apparatus5.1 Unrestrained movement mouldMoulds, complying with the requirements of 4.5 of EN 196-1:1994 except that there shall be a minimum of threecompartments, allowing simultaneous preparation of test specimens. Each compartment shall be provided a hole atthe centre of each end face to hold a measurement stud that is to be embedded in the specimen.5.2 Measurement studsStuds made of stainless steel, or other hard material that does not react with the mortar. Typical designs for Type 1recessed stud and Type 2 projecting stud are shown in Figures 1 and 2 respectively.NOTEThe design of the studs and the embedment method need to be compatible with the measuring apparatus used(see 5.3).5.3 Measuring apparatusApparatus used to measure the length of the test specimens. It shall be adjustable to give sufficient length tomeasure the minimum specimen length ± 5 mm and have an accuracy of measurement of ± 0,001 mm. It shallhave suitable fittings to receive the measurement studs (see 5.2).5.4 Calibration rodA rod made of invar metal or other material that has a similar coefficient of expansion over the range of testtemperatures. The calibration rod shall be (160 ± 1) mm in length and with ends of the same shape as themeasurement studs (see 5.2).NOTEIt is recommended that a second identical rod be available to serve as check for wear on the first rod and theseatings of the measuring apparatus (see 5.3), by comparing their apparent lengths at three-monthly intervals.SIST EN 12617-4:2002
EN 12617-4:2002 (E)65.5 TampersTampers consisting of sound, non-absorbent rods, of (38 ± 1) mm and (15 ± 1) mm in diameter and (200 ± 10) mmin length. The tamping face of each rod shall be flat and at right angles to the length of the tamper, the mass of thelarger tamper shall be (250 ± 15) g and the smaller tamper (40 ± 5
...