Radio-frequency connectors - Part 19: Sectional specification - Radio frequency coaxial connectors of type SSMB (IEC 61169-19:2011)

The SSMB series connectors with characteristic impedance 50 Ω are one kind of low power miniature connectors with snap-on coupling mechanism and have the characteristics of light weight, small size, convenient connection and excellent characteristics. This connector range is suitable for the standard ranges of flexible and semi-rigid cables and is also available as a PCB mounted version. The connectors are usable up to a frequency of 3 GHz.  This sectional specification provides information and rules for preparation of detail specification of SSMB series R.F connectors together with the pro forma blank detail specification.
It also prescribes mating face dimensions for grade 2 general purpose connectors,
dimensional detail of grade 0 standard test connectors, gauging information and tests selected from IEC 61169-1 applicable to all detail specifications relating to SSMB series RF connectors.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

Hochfrequenz-Steckverbinder - Teil 19: Rahmenspezifikation - Hochfrequenz-Koaxial-Steckverbinder des Typs SSMB (IEC 61169-19:2011)

Connecteurs pour fréquences radioélectriques - Partie 19: Spécification intermédiaire - Connecteurs coaxiaux pour fréquences radioélectriques de type SSMB (CEI 61169-19:2011)

La CEI 61169-19:2011 est une spécification intermédiaire. Elle fournit des informations et des règles en vue de l'établissement de spécifications particulières de connecteurs RF série SSMB, ainsi que la spécification particulière cadre pro-forma. Les connecteurs série SSMB d'impédance caractéristique de 50 ohm représentent un type de connecteurs miniatures de faible puissance avec mécanisme de couplage par encliquetage, et ils comportent des caractéristiques de légèreté, de petites dimensions, de connexion commode, ainsi que d'excellentes caractéristiques. Cette gamme de connecteurs convient aux gammes normalisées de câbles souples et semi-rigides et elle est également disponible en version de montage sur circuit imprimé. Les connecteurs sont utilisables jusqu'à une fréquence de 3 GHz. Elle prescrit également les dimensions des faces d'accouplement pour des connecteurs de classe 2 à usage général, les détails dimensionnels des connecteurs d'essai normalisés de classe 0, les informations concernant les calibres, et les essais choisis dans la CEI 61169-1, applicables à toutes les spécifications particulières ayant trait aux connecteurs RF série SSMB. La présente spécification indique les caractéristiques de performance recommandées à prendre en compte pour la rédaction d'une spécification particulière, et elle couvre les programmes d'essais et les exigences de contrôle pour les niveaux d'assurance qualité M  et H. Cette première édition annule et remplace la CEI/PAS 61169-19, publiée en 2009, dont elle constitue une révision mineure. Le seul changement est que le PAS a été changé en Norme internationale. La version française de cette norme n'a pas été soumise au vote.

Radiofrekvenčni konektorji - 19. del: Področna specifikacija - Radiofrekvenčni koaksialni konektorji vrste SSMB (IEC 61169-19:2011)

Konektorji serije SSMB z značilno impedanco 50 Ω so vrsta nizkoenergetskih miniaturnih konektorjev z natičnim spojnim mehanizmom in so lahki, majhni, primerni za povezovanje in imajo odlične lastnosti. Ta razpon konektorjev je primeren za uporabo pri standardnem razponu gibkih in poltogih kablov in je na voljo tudi kot različica, nameščena na ploščo tiskanega vezja. Konektorji so uporabni do frekvence 3 GHz. Ta področna specifikacija podaja informacije in pravila za pripravo podrobne specifikacije radiofrekvenčnih konektorjev serije SSMB skupaj s prazno predlogo za podrobno specifikacijo.
Predpisuje tudi dimenzije za združevanje za visokozmogljivostne konektorje stopnje 2, podrobnosti dimenzij standardnih preskusnih konektorjev stopnje 0, informacije in preskuse za umerjanje, izbrane iz IEC 61169-1, ki veljajo za vse podrobne specifikacije, povezane z radiofrekvenčnimi konektorji serije SSMB.
Ta specifikacija navaja priporočene značilnosti delovanja, ki jih je treba upoštevati pri pisanju podrobne specifikacije, in zajema razpored preskusov in zahteve za nadzor za ocenjevalne ravni M in H.

General Information

Status
Published
Publication Date
06-Apr-2011
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
17-Mar-2011
Due Date
22-May-2011
Completion Date
07-Apr-2011

Buy Standard

Standard
EN 61169-19:2011
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61169-19:2011
01-maj-2011
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD5DGLRIUHNYHQþQL
NRDNVLDOQLNRQHNWRUMLYUVWH660% ,(&
Radio-frequency connectors - Part 19: Sectional specification - Radio frequency coaxial
connectors of type SSMB (IEC 61169-19:2011)
Hochfrequenz-Steckverbinder - Teil 19: Rahmenspezifikation - Hochfrequenz-Koaxial-
Steckverbinder des Typs SSMB (IEC 61169-19:2011)
Connecteurs pour fréquences radioélectriques - Partie 19: Spécification intermédiaire -
Connecteurs coaxiaux pour fréquences radioélectriques de type SSMB (CEI 61169-
19:2011)
Ta slovenski standard je istoveten z: EN 61169-19:2011
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-19:2011 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61169-19:2011

---------------------- Page: 2 ----------------------

SIST EN 61169-19:2011

EUROPEAN STANDARD
EN 61169-19

NORME EUROPÉENNE
March 2011
EUROPÄISCHE NORM

ICS 33.120.30


English version


Radio-frequency connectors -
Part 19: Sectional specification -
Radio frequency coaxial connectors of type SSMB
(IEC 61169-19:2011)


Connecteurs pour fréquences Hochfrequenz-Steckverbinder -
radioélectriques - Teil 19: Rahmenspezifikation -
Partie 19: Spécification intermédiaire - Hochfrequenz-Koaxial-Steckverbinder des
Connecteurs coaxiaux pour fréquences Typs SSMB
radioélectriques de type SSMB (IEC 61169-19:2011)
(CEI 61169-19:2011)




This European Standard was approved by CENELEC on 2011-03-03. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-19:2011 E

---------------------- Page: 3 ----------------------

SIST EN 61169-19:2011
EN 61169-19:2011 - 2 -
Foreword
The text of document 46F/138/CDV, future edition 1 of IEC 61169-19, prepared by SC 46F, R.F. and
microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and
was approved by CENELEC as EN 61169-19 on 2011-03-03.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-12-03
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-03-03
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61169-19:2011 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 4 ----------------------

SIST EN 61169-19:2011
- 3 - EN 61169-19:2011
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 61169-1 1992 Radio-frequency connectors - EN 61169-1 1994
A1 1996 Part 1: Generic specification - General A1 1996
A2 1997 requirements and measuring methods A2 1997

---------------------- Page: 5 ----------------------

SIST EN 61169-19:2011

---------------------- Page: 6 ----------------------

SIST EN 61169-19:2011

IEC 61169-19
®

Edition 1.0 2011-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside


Radio-frequency connectors –
Part 19: Sectional specification – Radio frequency coaxial connectors of type
SSMB

Connecteurs pour fréquences radioélectriques –
Partie 19: Spécification intermédiaire – Connecteurs coaxiaux pour fréquences
radioélectriques de type SSMB

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 33.120.30 ISBN 978-2-88912-320-9
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 61169-19:2011
– 2 – 61169-19  IEC:2011
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General purpose connectors – Grade 2 . 6
3.1.1 Connector with socket-centre contact . 6
3.1.2 Connector with pin-centre contact . 8
3.2 Gauges . 9
3.2.1 Gauge pins for socket-centre contact . 9
3.2.2 Test procedure . 9
3.2.3 Gauge for outer contact of socket-centre contact . 10
3.2.4 Test procedure . 10
3.3 Dimensions – Standard test connectors – Grade 0 . 11
3.3.1 Connector with socket-centre contact . 11
3.3.2 Connector with pin-centre contact . 12
4 Quality assessment procedure . 13
4.1 General . 13
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) . 13
4.3 Test schedule and inspection requirements – Acceptance tests . 15
4.3.1 Acceptance tests . 15
4.3.2 Periodic tests . 16
4.4 Procedures . 18
4.4.1 Quality conformance inspection . 18
4.4.2 Qualification approval and its maintenance . 18
5 Instructions for preparation of detail specifications . 18
5.1 General . 18
5.2 Identification of the component . 18
5.3 Performance . 19
5.4 Marking, ordering information and related matters . 19
5.5 Selection of tests, test conditions and severities . 19
5.6 Blank detail specification pro-forma for type SSMB connector . 20

Figure 1 – Connector with socket-centre contact (for dimensions and notes, see Table 1) . 7
Figure 2 – Connector with pin-centre contact (for dimensions and notes, see Table 2) . 8
Figure 3 – Gauge pins for socket-centre contact (for dimensions and notes, see Table 3) . 9
Figure 4 – Outer contact sizing and retention force gauges A and B (for dimensions
and notes, see Table 4) . 10
Figure 5 – Connector with socket-centre contact (for dimensions and notes, see Table 5) . 11
Figure 6 – Connector with pin-centre contact (for dimensions and notes, see Table 6) . 12

Table 1 – Dimensions of connector with socket-centre contact . 7
Table 2 – Dimensions of connector with pin-centre contact . 8
Table 3 – Dimensions of gauge pins for socket-centre contact . 9
Table 4 – Dimensions of gauge for outer contact . 10
Table 5 – Dimensions of connector with socket-centre contact . 11

---------------------- Page: 8 ----------------------

SIST EN 61169-19:2011
61169-19  IEC:2011 – 3 –
Table 6 – Dimensions of connector with pin-centre contact . 12
Table 7 – Rating and characteristics . 13
Table 8 – Acceptance tests . 15
Table 9 – Periodic tests . 16

---------------------- Page: 9 ----------------------

SIST EN 61169-19:2011
– 4 – 61169-19  IEC:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

RADIO-FREQUENCY CONNECTORS –

Part 19: Sectional specification –
Radio frequency coaxial connectors of type SSMB


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-19 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This first edition cancels and replaces IEC/PAS 61169-19, published in 2009, of which it
constitutes a minor revision. The only change is that the PAS has been changed into and
International Standard.
The text of this standard is based on the following documents:
CDV Report on voting
46F/138/CDV 46F/163/RVC

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

---------------------- Page: 10 ----------------------

SIST EN 61169-19:2011
61169-19  IEC:2011 – 5 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, published under the general title Radio-frequency
connectors, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The “colour inside” logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this publication using a colour printer.

---------------------- Page: 11 ----------------------

SIST EN 61169-19:2011
– 6 – 61169-19  IEC:2011
RADIO-FREQUENCY CONNECTORS –

Part 19: Sectional specification –
Radio frequency coaxial connectors of type SSMB



1 Scope
The SSMB series connectors with characteristic impedance 50 Ω are one kind of low power
miniature connectors with snap-on coupling mechanism and have the characteristics of light
weight, small size, convenient connection and excellent characteristics. This connector range
is suitable for the standard ranges of flexible and semi-rigid cables and is also available as a
PCB mounted version. The connectors are usable up to a frequency of 3 GHz.
This sectional specification provides information and rules for preparation of detail
specification of SSMB series R.F connectors together with the pro forma blank detail
specification.
It also prescribes mating face dimensions for grade 2 general purpose connectors,
dimensional detail of grade 0 standard test connectors, gauging information and tests
selected from IEC 61169-1 applicable to all detail specifications relating to SSMB series RF
connectors.
This specification indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
1
requirements and measuring methods
Amendment 1 (1996)
Amendment 2 (1997)
3 Mating face and gauge information
3.1 Dimensions – General purpose connectors – Grade 2
3.1.1 Connector with socket-centre contact
All non-dimensioned pictorial configurations are for reference purpose only.
___________

1
There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Amendment 1:1996 and
its Amendment 2:1997.

---------------------- Page: 12 ----------------------

SIST EN 61169-19:2011
61169-19  IEC:2011 – 7 –

Note 1
f
i
d e
h
Note 3
j
Note 4

IEC  058/11

Figure 1 – Connector with socket-centre contact
(for dimensions and notes, see Table 1)
Table 1 – Dimensions of connector with socket-centre contact
mm
Ref.
Min. Max.
a 2,74 -
b -
c - 1,34
d - 1,78
e 0,84 -
f 0,84 -
g 2,11 (nominal)
h 3,10 -
i 0,00 -
j 2,77 -
NOTE 1 Reference plane.
NOTE 2 The form and dimension of outer contact detent
meet electrical and mechanical performance requirements.
NOTE 3 The diameters are chosen upon the assumption that
the PTFE dielectric has a dielectric constant of 2,02 to give an
impedance of 50 Ω.
NOTE 4 Resilient contact may be closed or open entry,
method of resilience is optional, provided that when a pin of
0,36 mm to 0,38 mm diameter is inserted, VSWR mating and
endurance performances are obtained.

∅a
∅b (Note 2)
∅c
∅g

---------------------- Page: 13 ----------------------

SIST EN 61169-19:2011
– 8 – 61169-19  IEC:2011
3.1.2 Connector with pin-centre contact
Note 1
See detail A
k
l
m
n
u
s
t
Note 2
w
x
Detail A

IEC  059/11

Figure 2 – Connector with pin-centre contact
(for dimensions and notes, see Table 2)
Table 2 – Dimensions of connector with pin-centre contact
mm
Ref.
Min. Max.
k - 3,10
l 1,91 -
m - 0,84
n 0,00 -
p 2,11 (nominal)
q 1,37 -
r - 2,67
s 0,00 -
t 0,71 0,74
u 88º~92º
v 0,05 0,15
w - 2,75
x 1,91 -
y - 0,25
z 0,36 0,38
NOTE 1 Reference plane.
NOTE 2 The diameters are chosen upon the assumption that
the PTFE dielectric has a dielectric constant of 2,02 to give an
impedance of 50 Ω.
∅p
∅y
∅q
∅z
∅r
v

---------------------- Page: 14 ----------------------

SIST EN 61169-19:2011
61169-19  IEC:2011 – 9 –
3.2 Gauges
3.2.1 Gauge pins for socket-centre contact
50° ± 2°
∅a
∅0,20 mm max.
Blend radius
R0,4 mm max.

IEC  055/11

Figure 3 – Gauge pins for socket-centre contact
(for dimensions and notes, see Table 3)
Table 3 – Dimensions of gauge pins for socket-centre contact
Gauge A Gauge B
Ref.
Maximum material for sizing Minimum material for measurement of retention
purposes force
mm mm
Min. Max. Min. Max.
a 0,381 0,384 0,353 0,356
b 1,70 1,80 1,70 1,80
Material: steel, polished, surface roughness: Ra=0,4 µm maximum.
Mass of gauge: 16 g ± 1 g

3.2.2 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of b .
This is a sizing operation and should only be carried out when the socket-centre contact is
removed from the connector.
After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position.
This test also shall be carried out on connector when the socket-centre contact is not
removed.
b

---------------------- Page: 15 ----------------------

SIST EN 61169-19:2011
– 10 – 61169-19  IEC:2011
3.2.3 Gauge for outer contact of socket-centre contact
a
g radius or
b
chamfer permissible
d radius
e radius f radius
k
Reference plane
j

IEC  060/11

Figure 4 – Outer contact sizing and retention force gauges A and B
(for dimensions and notes, see Table 4)
Table 4 – Dimensions of gauge for outer contact
Ref Gauge A (maximum Gauge B (minimum material for
material for sizing measurement of gauge retention
purpose) force)

mm mm
Min. Max. Min. Max.
a 0,74 0,75 0,58 0,64
b 0,48 0,51 0,43 0,46
c 0,14 0,15 0,075 0,125
d - 0,08 - 0,08
e 0,08 0,18 0,08 0,18
f 0,2 0,4 0,2 0,4
g - 0,38 - 0,38
h 1,68 - 1,68 -
i 2,672 2,675 2,667 2,670
k 3,05 3,10 3,05 3,10
j 3,50 - 3,50 -
Material: steel, polished, surface roughness: Ra=0,4 µm maximum.
Mass of gauge: 460 g ± 20 g

3.2.4 Test procedure
The gauge A shall be inserted into the outer contact of the socket-centre contact three times.
This is a sizing operation.
After this, the gauge B shall be inserted into the outer contact of the socket-centre contact.
The contact shall support the mass of the gauge in a vertical downward position.
c
∅h
∅i

---------------------- Page: 16 ----------------------

SIST EN 61169-19:2011
61169-19  IEC:2011 – 11 –
NOTE Additional test: Following the sizing operation, the force necessary to insert gauge A into the outer contact
of the socket-centre contact is measured. When this test is required, the maximum permitted insertion force is then
specified and is smaller than 27 N.
3.3 Dimensions – Standard test connectors – Grade 0
3.3.1 Connector with socket-centre contact
Note 1
A
∅0,12 mm
Note 2
e
d h
i g
0,012 mm
A
0,010 mm A
B
∅0,07 mm
Note 2
k
B
Note 3

IEC  061/11

Figure 5 – Connector with socket-centre contact
(for dimensions and notes, see Table 5)
Table 5 – Dimensions of connector with socket-centre contact
Ref. mm
Min. Max.
a 2,740 2,840
b 2,464 2,514
c 1,295 1,340
d - 1,780
e 0,000 0,127
f
2,110(nominal)
g 0,000 0,127
h 0,840 0,942
i 3,100 3,150
k 2,770 -
NOTE 1 Reference plane.
NOTE 2 The diameters are chosen upon the assumption that the PTFE
dielectric has a dielectric constant of 2,02 to give an impedance of
∅a
∅b
∅c
∅f

---------------------- Page: 17 ----------------------

SIST EN 61169-19:2011
– 12 – 61169-19  IEC:2011
50 Ω ± 0,5 Ω.
NOTE 3 Resilient contact may be closed or open entry, method of
resilience optional, provided that when a pin of 0,36 mm to 0,38 mm
diameter is inserted, VSWR mating and endurance performances are
obtained.
3.3.2 Connector with pin-centre contact
Note 1
See detail A
l
Note 2
m
n
p
x
A
∅0,12 mm A
r
q
t
Note 2
y
z
Detail A
B
∅0,075 mm
B

IEC  062/11

Figure 6 – Connector with pin-centre contact
(for dimensions and notes, see Table 6)
Table 6 – Dimensions of connector with pin-centre contact
Ref. mm
Min. Max.
l 3,050 3,100
m 1,905 -
n 0,740 0,840
p 0,000 0,127
q 0,710 0,740
r 89° to 91°
s 0,120 0,150
t 0,080 radius
u
2,110(nominal)
v 1,370 1,420
w 2,620 2,670
x 0,000 0,050
y - 2,750
z 1,910 -
∅u
∅aa
∅ab
∅v
∅w
s

---------------------- Page: 18 ----------------------

SIST EN 61169-19:2011
61169-19  IEC:2011 – 13 –
Ref. mm
Min. Max.
aa - 0,250
ab 0,360 0,380
NOTE 1 Reference plane.
NOTE 2 The diameters are chosen upon the assumption that
the PTFE dielectric has a dielectric constant of 2,02 to give
an impedance of 50 Ω ± 0,5 Ω.

4 Quality assessment procedure
4.1 General
The following subclauses provide recommended rating, performance and test conditions to be
considered when writing a detail specification. They also provide an appropriate schedule of
tests with minimum levels of conformance inspection sampling, together with the pro-forma
blank detail specification (BDS) and instructions for the preparation of a detail specification.
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1)
The values indicated below are recommended for SSMB series RF connectors and are given
for the writer of the detail specification. They are applicable for the condition when the
connectors are fully mated.
Certain tests are listed without any recommended values being given. These tests will usually
not be required. When these tests are required, appropriate values shall be entered in the
detail specification at the discretion of the specification writer.
Table 7 – Rating and characteristics
Remarks,
IEC 61169-1 deviations from
Rating and characteristics Values
Subclause standard test
method
Electrical
Nominal impedance 50 Ω
Frequency range  Up to 3 GHz
a
Reflection factor 9.2.1
 Grade 2 connectors
– straight styles Up to 1 GHz
≤0,1
 Up to 3 GHz
≤0,15
– right-angle styles Up to 1 GHz
≤0,2
 Up to 3 GHz
≤0,24
– component mounting styles
See DS
– solder bucket and PCB mounting styles
See DS
b
Centre contact resistance 9.2.3
– initial
≤ 5,0 mΩ
– after conditioning
≤ 15,0 mΩ
b
Outer conductor continuity 9.2.3
– initial ≤ 2,5 mΩ
– after conditioning
≤ 7,5 mΩ
a
Insulation resistance 9.2.5
– initial
≥ 1 000 MΩ
– after conditioning
≥ 200 MΩ

---------------------- Page: 19 ----------------------

SIST EN 61169-19:2011
– 14 – 61169-19  IEC:2011
Remarks,
IEC 61169-1 deviations from
Rating and characteristics Values
Subclause standard test
method
c d
Proof voltage at sea level 9.2.6 500 V
c d
Proof voltage at 4,4 kPa 9.2.6 100 V 4,4 kPa
approximately
equivalent to 20 km
c d
Environmental voltage at sea level  250 V
c d
Environmental voltage at 4,4 kPa  85 V 4,4 kPa
approximately
equivalent to 20 km
Screening effectiveness (straight cables 9.2.8
≥ 40 dB at
f
only)
1 GHz
Mechanical
Gauge retention force (resilient contacts) 9.3.4
– centre contact ≥ 0,15 N
– outer contact
≥ 4,5 N
Centre contact captivation 9.3.5
– axial force  Maximum
≥ 8,9 N
displacement


0,25 mm in each


direction
Engagement and separation 9.3.6
– separation force
≥ 4,5 N
– insertion force
≤ 27 N
Mechanical tests on cable fixing
– cable rotation (nutation) 9.3.7.2 See DS
– cable pulling 9.3.8 See DS
– cable bending 9.3.9 See DS
– cable torsion  9.3.10 See DS
Bending moment 9.3.12 See DS
2
Vibration 9.3.3 100 m/s  10 g
n

10 Hz ~500 Hz
Shock 9.3.14
See DS
Environmental
Climatic category 9.4.2 A:55/125/21
B:40/085/21


3
Sealing non-hermetic 9.4.5.1 100 kPa to 110 kPa
≤100 kPa·cm /h
differential
Hermetic 9.4.5.2 100 kPa to 110 kPa

–3 3
≤10 Pa·cm /s
differential
Salt mist 9.4.6 48 h spray
Endurance
Mechanical endurance 9.5 500 operations
e
High temperature endurance 9.6 Category A:
250 h at 125 °C
Category B:
250 h at 85 °C

---------------------- Page: 20 ----------------------

SIST EN 61169-19:2011
61169-19  IEC:2011 – 15 –

a
These values apply to basic connector. In practice, these may be influenced by the cable used and
reference should always be made to the actual values given in the detail specification.
b
Values for a single pair of connectors.
c
Voltages are r.m.s. values of a.c. at 40 Hz to 65 Hz, unless otherwise specified.
d
Some cables usable with these connectors have ratings lower than the values given here.
e
For certain connectors, the upper temperature limit is restricted by the cable characteristics. Reference
should be made to the relevant cable specification. When semi-rigid and semi-flexible cables are used, the
upper temperature is limited to 115 °C maximum.
f
When interfaces are fully mated.
4.3 Test schedule and inspection requirements – Acceptance tests
4.3.1 Acceptance tests
Table 8 – Acceptance tests
Test method Assessment level M (higher) Assessment level H (lower)


Test Test
IEC61169-1
IL AQL % Period IL AQL % Period
required required
subclause
Group A1

Visual 9.1.2 a II 1,0 S-3 1,5
a
examination
Group B1
Lot Lot
Outline dimension
...

Questions, Comments and Discussion