Water meters for cold potable water and hot water - Part 3: Test report format (ISO 4064-3:2024)

This document specifies a test report format to be used in conjunction with ISO 4064-1:2024|OIML R 49-1:2024 and ISO 4064-2:2024|OIML R 49-2:2024 for water meters for cold potable water and hot water.

Wasserzähler zum Messen von kaltem Trinkwasser und heißem Wasser - Teil 3: Format des Prüfberichtes (ISO 4064-3:2024)

Dieses Dokument legt ein Prüfberichtformat fest, das in Verbindung mit ISO 4064 1:2024|OIML R 49 1:2024 und ISO 4064 2:2024|OIML R 49 2:2024 für Wasserzähler zum Messen von kaltem Trinkwasser und heißem Wasser anzuwenden ist.

Compteurs d'eau potable froide et d'eau chaude - Partie 3: Format du rapport d'essais (ISO 4064-3:2024)

Le présent document spécifie le format du rapport d’essai à utiliser dans le contexte de la mise en œuvre de l’ISO 4064-1:2024|OIML R 49-1:2024 et de l’ISO 4064-2:2024|OIML R 49-2:2024 pour les compteurs d’eau potable froide et d’eau chaude.

Vodomeri za merjenje hladne pitne vode in vroče vode - 3. del: Obrazec za poročilo o preskusu (ISO 4064-3:2024)

Standard ISO 4064-3:2014|OIML R 49-3:2013 določa obrazec za poročilo o preskusu, ki se v povezavi s standardoma ISO 4064-1:2014|OIML R 49-1:2013 in ISO 4064-2:2014|OIML R 49-2:2013 uporablja za vodomere za merjenje hladne pitne vode in vroče vode.

General Information

Status
Published
Public Enquiry End Date
28-Dec-2023
Publication Date
21-Jan-2025
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
16-Jan-2025
Due Date
23-Mar-2025
Completion Date
22-Jan-2025

Relations

Standard
SIST EN ISO 4064-3:2025
English language
78 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-marec-2025
Vodomeri za merjenje hladne pitne vode in vroče vode - 3. del: Obrazec za poročilo
o preskusu (ISO 4064-3:2024)
Water meters for cold potable water and hot water - Part 3: Test report format (ISO 4064
-3:2024)
Wasserzähler zum Messen von kaltem Trinkwasser und heißem Wasser - Teil 3: Format
des Prüfberichtes (ISO 4064-3:2024)
Compteurs d'eau potable froide et d'eau chaude - Partie 3: Format du rapport d'essais
(ISO 4064-3:2024)
Ta slovenski standard je istoveten z: EN ISO 4064-3:2025
ICS:
17.120.10 Pretok v zaprtih vodih Flow in closed conduits
91.140.60 Sistemi za oskrbo z vodo Water supply systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN ISO 4064-3
EUROPEAN STANDARD
NORME EUROPÉENNE
January 2025
EUROPÄISCHE NORM
ICS 91.140.60 Supersedes EN ISO 4064-3:2014
English Version
Water meters for cold potable water and hot water - Part
3: Test report format (ISO 4064-3:2024)
Compteurs d'eau potable froide et d'eau chaude - Wasserzähler zum Messen von kaltem Trinkwasser
Partie 3: Format du rapport d'essai (ISO 4064-3:2024) und heißem Wasser - Teil 3: Format des Prüfberichtes
(ISO 4064-3:2024)
This European Standard was approved by CEN on 18 November 2024.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 4064-3:2025 E
worldwide for CEN national Members.

Contents Page
European foreword . 3

European foreword
This document (EN ISO 4064-3:2025) has been prepared by Technical Committee ISO/TC 30
"Measurement of fluid flow in closed conduits" in collaboration with Technical Committee CEN/TC 92
“Water meters” the secretariat of which is held by SNV.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by July 2025, and conflicting national standards shall be
withdrawn at the latest by July 2025.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 4064-3:2014.
Any feedback and questions on this document should be directed to the users’ national standards
body/national committee. A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the
United Kingdom.
Endorsement notice
The text of ISO 4064-3:2024 has been approved by CEN as EN ISO 4064-3:2025 without any
modification.
International
Standard
ISO 4064-3
Fifth edition
Water meters for cold potable water
2024-12
and hot water —
Part 3:
Test report format
Compteurs d’eau potable froide et d’eau chaude —
Partie 3: Format du rapport d’essai
Reference number
ISO 4064-3:2024(en) © ISO 2024

ISO 4064-3:2024(en)
© ISO 2024
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
ISO 4064-3:2024(en)
Contents Page
Foreword .v
Introduction .vi
1 Scope . 1
2 Normative references . 1
3 Terms, definitions, symbols, and abbreviated terms . 1
4 Type evaluation report . 1
4.1 General .1
4.2 Information concerning the type .2
4.2.1 General .2
4.2.2 Model submitted .2
4.2.3 Mechanical water meter (complete or combined) .3
4.2.4 Electronic water meter (complete or combined) .4
4.2.5 Separable calculator (including indicating device) .6
4.2.6 Separable measurement transducer (including flow or volume sensor) .7
4.2.7 Supplementary electronic device(s) used for testing (permanently attached to
meter) .9
4.2.8 Supplementary electronic device(s) used for data transmission (permanently
attached to meter) . .9
4.2.9 Supplementary electronic device(s) used for testing (temporarily attached to
meter) .10
4.2.10 Supplementary electronic device(s) used for data transmission (temporarily
attached to meter) . .10
4.2.11 Ancillary devices .10
4.2.12 Documents concerning the type .11
4.3 General information concerning the test equipment .11
4.4 Check list for water meter examinations and performance tests. 12
4.4.1 Check list for water meter examinations . 12
4.4.2 Checklist for water meter performance tests .16
4.5 Type evaluation tests (for all water meters) .21
4.5.1 Static pressure test (ISO 4064-2:2024|OIML R 49-2:2024, 7.3) .21
4.5.2 Determination of changeover flow rates for combination meters (ISO 4064-
2:2024|OIML R 49-2:2024, 7.4.3) . 22
4.5.3 Determination of the intrinsic errors (of indication) and the effects of meter
orientation (ISO 4064-2:2024|OIML R 49-2:2024, 7.4.4) . 23
4.5.4 Interchange test on all types of cartridge meters and meters with exchangeable
metrological modules (ISO 4064-1:2024|OIML R 49-1:2024, 7.2.7, ISO 4064-
2:2024|OIML R 49-2:2024, 7.4.4, 7.4.6) . 25
4.5.5 Water temperature test (ISO 4064-2:2024|OIML R 49-2:2024, 7.5) and overload
water temperature test (ISO 4064-2:2024|OIML R 49-2:2024, 7.6) .27
4.5.6 Water pressure test (ISO 4064-2:2024|OIML R 49-2:2024, 7.7) . 28
4.5.7 Reverse flow test (ISO 4064-2:2024|OIML R 49-2:2024, 7.8) . 29
4.5.8 Pressure-loss test (ISO 4064-2:2024|OIML R 49-2:2024, 7.9) . 30
4.5.9 Flow disturbance tests (ISO 4064-2:2024|OIML R 49-2:2024, 7.10, Annex C) .31
4.5.10 Durability tests (ISO 4064-2:2024|OIML R 49-2:2024, 7.11) . . 33
4.5.11 Static magnetic field test (ISO 4064-2:2024|OIML R 49-2:2024, 7.12, 8.16). 39
4.5.12 Tests on ancillary devices of a water meter (ISO 4064-2:2024|OIML R 49-2:2024,
7.13) . 40
4.6 Type evaluation tests (for electronic water meters and mechanical water meters with
electronic components) .43
4.6.1 Dry heat (non-condensing) (ISO 4064-2:2024|OIML R 49-2:2024, 8.2) .43
4.6.2 Cold (ISO 4064-2:2024|OIML R 49-2:2024, 8.3). 44
4.6.3 Damp heat, cyclic (condensing) (ISO 4064-2:2024|OIML R 49-2:2024, 8.4) .45
4.6.4 Power supply variation (ISO 4064-2:2024|OIML R 49-2:2024, 8.5) . 46
4.6.5 Vibration (random) (ISO 4064-2:2024|OIML R 49-2:2024, 8.6) . 48

iii
ISO 4064-3:2024(en)
4.6.6 Mechanical shock (ISO 4064-2:2024|OIML R 49-2:2024, 8.7) . 49
4.6.7 AC mains voltage dips, short interruptions and voltage variations (ISO 4064-
2:2024|OIML R 49-2:2024, 8.8) . 50
4.6.8 Bursts on signal lines (ISO 4064-2:2024|OIML R 49-2:2024, 8.9) .51
4.6.9 Bursts (transients) on AC and DC mains (ISO 4064-2:2024|OIML R 49-2:2024,
8.10) .52
4.6.10 Electrostatic discharge (ISO 4064-2:2024|OIML R 49-2:2024, 8.11) . 54
4.6.11 Radiated electromagnetic field (ISO 4064-2:2024|OIML R 49-2:2024, 8.12) . 55
4.6.12 Conducted electromagnetic field (ISO 4064-2:2024|OIML R 49-2:2024, 8.13) .57
4.6.13 Surges on signal, data and control lines (ISO 4064-2:2024|OIML R 49-2:2024,
8.14) (applicable only for environmental class E2) . 58
4.6.14 Surges on AC and DC mains power lines (ISO 4064-2:2024|OIML R 49-2:2024,
8.15) (applicable only for environmental class E2) .59
4.6.15 Absence of flow test (ISO 4064-2:2024|OIML R 49-2:2024, 8.17) . 63
5 Initial verification report .63
5.1 General . 63
5.2 Information concerning the EUT verified . 64
5.3 Initial verification test report (ISO 4064-2:2024|OIML R 49-2:2024, Clause 10) . 65
Annex A (normative) Template of a list of documents concerning the type (ISO 4064-
1:2024|OIML R 49-1:2024, 7.2.9) .69

iv
ISO 4064-3:2024(en)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 30, Measurement of fluid flow in closed
conduits, Subcommittee SC 7, Volume methods including water meters and OIML Technical Subcommittee
TC 8/SC 5, Water meters, in collaboration with the European Committee for Standardization (CEN) Technical
Committee CEN/TC 92, Water meters, in accordance with the Agreement on technical cooperation between
ISO and CEN (Vienna Agreement).
This fifth edition of ISO 4064-3 cancels and replaces the fourth edition (ISO 4064-3:2014), which has been
technically revised.
This edition of ISO 4064-3 is identical to the corresponding edition of OIML R 49-3 and OIML R49-4, which
will be submitted for approval for final publication by the International Committee of Legal Metrology at
th
its 59 meeting in October 2024. It will be submitted to the International Conference on Legal Metrology in
2024 for formal sanction.
A list of all parts in the ISO 4064 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.

v
ISO 4064-3:2024(en)
Introduction
Implementation of this test report format is informative with regard to the implementation of
ISO 4064-1:2024|OIML R 49-1:2024 and ISO 4064-2:2024|OIML R 49-2:2024 in national regulations;
however, its implementation is required within the framework of the OIML Certificate System for Measuring
Instruments [ISO 4064-2:2024|OIML R 49-2:2024, 11.1].
Clause 4 shows the required format of a type evaluation report for a complete or combined water meter.
A type evaluation report for a separable calculator (including indicating device) or a measurement transducer
(including flow or volume sensor) requires a similar format. However, some modifications to the tables may
be required because a large number of variations in the design of these separable units is possible.
Some examples of tables for presenting the test results for separable units are shown in Clause 5 for initial
verifications. These tables can also be adapted for type evaluation reports.

vi
International Standard ISO 4064-3:2024(en)
Water meters for cold potable water and hot water —
Part 3:
Test report format
1 Scope
This document specifies a test report format to be used in conjunction with ISO 4064-1:2024|OIML R 49-
1:2024 and ISO 4064-2:2024|OIML R 49-2:2024 for water meters for cold potable water and hot water.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 4064-1:2024|OIML R 49-1:2024, Water meters for cold potable water and hot water —
Part 1: Metrological and technical requirements
ISO 4064-2:2024|OIML R 49-2:2024, Water meters for cold potable water and hot water —
Part 2: Test methods
3 Terms, definitions, symbols, and abbreviated terms
For the purposes of this document, the terms and definitions given in ISO 4064-1|OIML R 49-1 apply.
Some symbols and abbreviated terms used in the tables are as follows.
+ pass
− fail
n/a not applicable
EUT equipment under test
H horizontal
MAP maximum admissible pressure
MAT maximum admissible temperature
MPE maximum permissible error
V vertical
4 Type evaluation report
4.1 General
For each examination and test the checklist shall be completed according to this example:

ISO 4064-3:2024(en)
4.2 Information concerning the type
4.2.1 General
Application num- _________________________________
ber:
Applicant: _________________________________
Authorized _________________________________
representative:
Address: _________________________________
_________________________________
_________________________________
_________________________________
Testing _________________________________
laboratory:
Authorized _________________________________
representative:
Address: _________________________________
_________________________________
_________________________________
_________________________________
4.2.2 Model submitted
New model: _________________________________
Variant of approved model(s):
Approval number: _________________________________
Variation of approved model: _________________________________
See Table 1.
ISO 4064-3:2024(en)
Table 1 — Model submitted
a a
Submitted for approval tests Yes No Remarks
Mechanical water meter (complete)
Mechanical water meter (combined)
Electronic water meter (complete)
Electronic water meter (combined)
Family of water meters
Separable calculator (including indicating device)
Separable measurement transducer (including flow or
volume sensor)
Supplementary electronic device(s) for testing (perma-
nently attached to meter)
Supplementary electronic device(s) for data transmis-
sion (permanently attached to meter)
Supplementary electronic device(s) for testing (tempo-
rarily attached to meter)
Supplementary electronic device(s) for data transmis-
sion (temporarily attached to meter)
Ancillary devices
a)
Tick as appropriate.
4.2.3 Mechanical water meter (complete or combined)
Manufacturer: __________________________________________________
Model number: __________________________________________________
Type details:
Q _________ m /h
Q _________ m /h
Q _________ m /h
Q _________ m /h
Q /Q _________
3 1
for combination meters
Q _________ m /h
x1
Q _________ m /h
x2
Measuring principle: __________________________
Accuracy class: _____________
Temperature class: _____________
Environmental class: _____________
Electromagnetic environment: _____________
Maximum admissible _________ °C
temperature:
Maximum admissible pressure: ___________ MPa (_____ bar)

ISO 4064-3:2024(en)
Orientation limitation: _________________________
Pressure loss class:
Reverse flow:
a) Meters designed to measure
reverse flow
b) Meters not designed to
measure reverse flow
c) Meters which prevent reverse
flow
EUT testing requirements (ISO 4064-2:2024|OIML R 49-2:2024, 8.1.8):
Category: _________________________
Case: _________________________
Installation details:
Connection type (flange, screw _________
thread, concentric manifold):
Minimum straight length of inlet __________ mm
pipe:
Minimum straight length of outlet __________ mm
pipe:
Flow conditioner (details if re- _________________________
quired):
Mounting: _________________________
Orientation: _________________________
Other relevant information: _________________________
If a family of meters is submitted, the details in this subclause are to be given for each size of water meter.
4.2.4 Electronic water meter (complete or combined)
Manufacturer: __________________________________________________
Model number: __________________________________________________
Type details:
Q _________ m /h
Q _________ m /h
Q _________ m /h
Q _________ m /h
Q /Q _________
3 1
ISO 4064-3:2024(en)
Maximum sampling in- _________ s
terval in user mode:
for combination meters
Q _________ m /h
x1
Q _________ m /h
x2
Measuring principle: __________________________
Accuracy class: _____________
Temperature class: _____________
Environmental class: _____________
Electromagnetic environment: _____________
Maximum admissible temperature: _________ °C
Maximum admissible pressure: ___________ MPa (_____ bar)
Orientation limitation: _________________________
Pressure loss class:
Reverse flow:
a) Meters designed to measure reverse
flow
b) Meters not designed to measure reverse
flow
c) Meters which prevent reverse flow
Software version (if applicable):
EUT testing requirements (ISO 4064-2:2024|OIML R 49-2:2024, 8.1.8):
Category: _________________________
Case: _________________________
Installation details (mechanical):
Connection type (flange, screw thread, _________
concentric manifold):
Minimum straight length of inlet pipe: __________ mm
Minimum straight length of outlet pipe: __________ mm
Flow conditioner (details if required): _________________________
Mounting: _________________________
Orientation: _________________________
Other relevant information: _________________________
Installation details (electrical):

ISO 4064-3:2024(en)
Wiring instructions: _________________________
Mounting arrangement: _________________________
Orientation limitations: _________________________
Power supply:
Type (battery, mains AC, mains DC): _________________________
U : ______________________ V
max
U : ______________________ V
min
Frequency: _______________________ Hz
If a family of meters is submitted, the details in this subclause are to be given for each size of water meter.
4.2.5 Separable calculator (including indicating device)
Manufacturer: __________________________________________________
Model number: __________________________________________________
Type details:
Q _________ m /h
Q _________ m /h
Q _________ m /h
Q _________ m /h
Q /Q _________
3 1
for combination meters
Q _________ m /h
x1
Q _________ m /h
x2
Measuring principle: __________________________
Accuracy class: _____________
Temperature class: _____________
Environmental class: _____________
Electromagnetic environment: _____________
Maximum admissible temperature: _________°C
Maximum admissible pressure: ___________MPa (_____ bar)
Orientation limitation: _________________________
Pressure loss class:
ISO 4064-3:2024(en)
Reverse flow:
a) Meters designed to measure reverse
flow
b) Meters not designed to measure reverse
flow
c) Meters which prevent reverse flow
Software version (if applicable):
EUT testing requirements (ISO 4064-2:2024|OIML R 49-2:2024, 8.1.8):
Category: _________________________
Case: _________________________
Maximum relative error specified by the manufacturer:
Lower flow rate zone, Q ≤ Q < Q : ________________________%
1 2
Upper flow rate zone, Q ≤ Q ≤ Q : ________________________%
2 4
Installation details (electrical):
Wiring instructions: _________________________
Mounting arrangement: _________________________
Orientation limitations: _________________________
Power supply:
Type (battery, mains AC, mains DC): _________________________
U : ________________________ V
max
U : ________________________ V
min
Frequency: _______________________ Hz
Approval number(s) of compatible measure-
ment transducer(s) (including flow or volume
sensor): ____________________
4.2.6 Separable measurement transducer (including flow or volume sensor)
Manufacturer: __________________________________________________
Model number: __________________________________________________
Type details:
Q _________ m /h
Q _________ m /h
ISO 4064-3:2024(en)
Q _________ m /h
Q _________ m /h
Q /Q _________
3 1
for combination meters
Q _________ m /h
x1
Q _________ m /h
x2
Measuring principle: __________________________
Accuracy class: _____________
Temperature class: _____________
Environmental class: _____________
Electromagnetic environment: _____________
Maximum admissible temperature: _________°C
Maximum admissible pressure: ___________MPa (_____ bar)
Orientation limitation: _________________________
EUT testing requirements (ISO 4064-2:2024|OIML R 49-2:2024, 8.1.8):
Category: _________________________
Case: _________________________
Maximum relative error specified by the manufacturer:
Lower flow rate zone, Q ≤ Q < Q : ________________________%
1 2
Upper flow rate zone, Q ≤ Q ≤ Q : ________________________%
2 4
Installation details (mechanical):
Connection type (flange, screw thread, concentric manifold): _________
Minimum straight length of inlet pipe: __________mm
Minimum straight length of outlet pipe: __________mm
Flow conditioner (details if required): _________________________
Mounting: _________________________
Orientation: _________________________
Other relevant information: _________________________
Installation details (electrical):
Wiring instructions: _________________________
Mounting arrangement: _________________________
Orientation limitations: _________________________
Power supply:
ISO 4064-3:2024(en)
Type (battery, mains AC, mains DC): _________________________
U : ________________________ V
max
U : ________________________ V
min
Frequency: _______________________ Hz
Approval number(s) of compatible calculator(s)
(including indicating device): _________________________
4.2.7 Supplementary electronic device(s) used for testing (permanently attached to meter)
Manufacturer: __________________________________________________
Model number: __________________________________________________
Power supply:
Type (battery, mains AC, mains DC): _________________________
U : ________________________ V
max
U : ________________________ V
min
Frequency: _______________________ Hz
Installation details (electrical):
Wiring instructions: _________________________
Mounting arrangement: _________________________
Orientation limitations: _________________________
4.2.8 Supplementary electronic device(s) used for data transmission (permanently attached to meter)
Manufacturer: __________________________________________________
Model number: __________________________________________________
Power supply:
Type (battery, mains AC, mains DC): _________________________
U : ________________________ V
max
U : ________________________ V
min
Frequency: _______________________ Hz
Installation details (electrical):
Wiring instructions: _________________________
Mounting arrangement: _________________________
Orientation limitations: _________________________

ISO 4064-3:2024(en)
4.2.9 Supplementary electronic device(s) used for testing (temporarily attached to meter)
Manufacturer: __________________________________________________
Model number: __________________________________________________
Power supply:
Type (battery, mains AC, mains DC): _________________________
U : ________________________ V
max
U : ________________________ V
min
Frequency: _______________________ Hz
Installation details (electrical):
Wiring instructions: _________________________
Mounting arrangement: _________________________
Orientation limitations: _________________________
4.2.10 Supplementary electronic device(s) used for data transmission (temporarily attached to meter)
Manufacturer: __________________________________________________
Model number: __________________________________________________
Power supply:
Type (battery, mains AC, mains DC): _________________________
U : ________________________ V
max
U : ________________________ V
min
Frequency: _______________________ Hz
EUT testing requirements (ISO 4064-2:2024|OIML R 49-2:2024, 8.1.8):
Category: _________________________
Case: _________________________
Installation details (electrical):
Wiring instructions: _________________________
Mounting arrangement: _________________________
Orientation limitations: _________________________
4.2.11 Ancillary devices
Manufacturer: __________________________________________________
Model number: __________________________________________________

ISO 4064-3:2024(en)
Power supply:
Type (battery, mains AC, mains DC): _________________________
U : ________________________ V
max
U : ________________________ V
min
Frequency: _______________________ Hz
Approval number(s) of compatible calculator(s)
(including indicating device): _________________________
EUT testing requirements (ISO 4064-2:2024|OIML R 49-2:2024, 8.1.8):
Category: _________________________
Case: _________________________
Installation details (electrical):
Wiring instructions: _________________________
Mounting arrangement: _________________________
Orientation limitations: _________________________
Approval number(s) of compatible water me-
ters, calculator(s) (including indicating device)
and measurement transducer(s) (including flow
or volume sensor): _________________________
4.2.12 Documents concerning the type
A list of documents in accordance with ISO 4064-1:2024|OIML R 49-1:2024, 7.2.9, shall be submitted with the
type approval application as in Annex A.
4.3 General information concerning the test equipment
Details of the main items of measuring equipment and test instruments used for the type examinations, or
initial verifications are listed in Table 2.
Table 2 — Listing of test equipment used in examinations and tests
Used in performance
test No.
Manufacturer Model Serial number Comments
(ISO 4064-2:2024|
OIML R 49-2:2024,
subclause)
All calibration periods of test equipment used in examinations and tests listed above are in the quality system documentation of
the test laboratory. Measurement equipment are traceable to the International System of Units.

ISO 4064-3:2024(en)
4.4 Check list for water meter examinations and performance tests
4.4.1 Check list for water meter examinations
Table 3
External examination for all water meters
ISO 4064-1:2024|
OIML R 49-1:2024, Requirement + − Remarks
subclause
Function of the indicating device
6.7.1.1 The indicating device shall provide an easily read, reliable and
unambiguous visual indication of the indicated volume
6.7.1.1 The indicating device shall include visual means for testing and
calibration.
6.7.1.1 The indicating device may include additional elements for test-
ing and calibration by other methods, e.g. for automatic testing
and calibration
Unit of measurement and its placement
6.7.1.2 The indicated volume of water shall be expressed in cubic
metres
6.7.1.2 The symbol m shall appear on the dial or immediately adja-
cent to the numbered display
Indicating range
3 3
6.7.1.3 For Q ≤ 6,3, the minimum indicating range is 0 m to 9 999 m
6.7.1.3 For 6,3 < Q ≤ 63, the minimum indicating range is 0 m to
99 999 m
6.7.1.3 For 63 < Q ≤ 630, the minimum indicating range is 0 m to
999 999 m
6.7.1.3 For 630 < Q ≤ 6 300, the minimum indicating range is 0 m to
9 999 999 m
Colour coding for indicating device
6.7.1.4 The colour black should be used to indicate the cubic metre and
its multiples
6.7.1.4 The colour red should be used to indicate sub-multiples of a
cubic metre
6.7.1.4 The colours shall be applied to either the pointers, indexes,
numbers, wheels, discs, dials or aperture frames
6.7.1.4 Other means of indicating the cubic metre may be used pro-
vided there is no ambiguity in distinguishing between the
primary indication and alternative displays, e.g. sub-multiples
for verification and testing
Types of indicating device: Type 1 — Analogue device
6.7.2.1 The indicated volume shall be shown by continuous movement
of either:
a)  one or more pointers moving relative to graduated scales;
or
b)  one or more circular scales or drums each passing an index
6.7.2.1 The value expressed in cubic metres for each scale division
n
shall be of the form 10 , where n is a positive or a negative
whole number or zero, thereby establishing a system of consec-
utive decades.
ISO 4064-3:2024(en)
TTabablele 3 3 ((ccoonnttiinnueuedd))
External examination for all water meters
ISO 4064-1:2024|
OIML R 49-1:2024, Requirement + − Remarks
subclause
6.7.2.1 The scale shall be graduated in values expressed in cubic me-
tres or accompanied by a multiplying factor
(×0,001; ×0,01; ×0,1; ×1; ×10; ×100; ×1 000 etc.)
6.7.2.1 Rotational movement of the pointers or circular scales shall be
clockwise
6.7.2.1 Linear movement of pointers or scales shall be left to right
6.7.2.1 Movement of numbered roller indicators shall be upwards
Types of indicating device: Type 2 — Digital device
6.7.2.2 The indicated volume is given by a line of digits appearing in
one or more apertures
6.7.2.2 The advance of one digit shall be completed while the digit of
the next immediately lower decade changes from 9 to 0
6.7.2.2 The apparent height of the digits shall be at least 4 mm
6.7.2.2 For non-electronic devices, movement of numbered roller indi-
cators (drums) shall be upwards
6.7.2.2 For non-electronic devices, the lowest value decade may have
a continuous movement, the aperture being large enough to
permit a digit to be read without ambiguity
6.7.2.2 For electronic devices with non-permanent displays the vol-
ume shall be able to be displayed at any time for at least 10 s
6.7.2.2 For electronic devices, the meter shall provide visual checking
of the entire display which shall have the following sequence:
—  for seven segment type displaying all the elements (e.g. an
“eights” test); and
—  for seven segment type blanking all the elements (a
“blanks” test).
For graphical displays, an equivalent test is required to
demonstrate that display faults cannot result in any digit being
misinterpreted.
Each step of the sequence shall last at least 1 s
Types of indicating device: Type 3 — Combination of analogue and digital devices
6.7.2.3 The indicated volume is given by a combination of type 1 and
type 2 devices and the respective requirements of each shall
apply
Verification devices — General requirements
6.7.3.1 Every indicating device shall provide means for visual, non-am-
biguous verification testing and calibration
6.7.3.1 The visual verification may have either a continuous or a dis-
continuous movement
6.7.3.1 In addition to the visual verification display, an indicating de-
vice may include provisions for rapid testing by the inclusion of
complementary elements (e.g. star wheels or discs), providing
signals through externally attached sensors.
Verification devices — Visual verification displays
6.7.3.2.1 The value of the verification scale interval, expressed in cubic
n n n
metres, shall be of the form:1 × 10 , 2 × 10 or 5 × 10 , where n
is a positive or negative whole number, or zero
6.7.3.2. The indicated volume is given by a line of digits appearing in
one or more apertures
ISO 4064-3:2024(en)
TTabablele 3 3 ((ccoonnttiinnueuedd))
External examination for all water meters
ISO 4064-1:2024|
OIML R 49-1:2024, Requirement + − Remarks
subclause
6.7.3.2.1 For analogue or digital indicating devices with continuous
movement of the first element, the verification scale interval
may be formed from the division into 2, 5 or 10 equal parts of
the interval between two consecutive digits of the first ele-
ment. Numbering shall not be applied to these divisions
6.7.3.2.1 For digital indicating devices with discontinuous movement of
the first element, the verification scale interval is the interval
between two consecutive digits or incremental movements of
the first element
6.7.3.2.2 On indicating devices with continuous movement of the first
element, the apparent scale spacing shall be not less than 1 mm
and not more than 5 mm
6.7.3.2.2 The scale shall consist of either:
a)  lines of equal thickness not exceeding one quarter of the
scale spacing and differing only in length; or
b)  contrasting bands of a constant width equal to the scale
spacing
6.7.3.2.2 The apparent width of the pointer at its tip shall not exceed
one-quarter of the scale spacing and in no case shall it be great-
er than 0,5 mm
Resolution of the indicating device
6.7.3.2.3 The sub-divisions of the verification scale shall be small
enough to ensure that the resolution of the indicating device
does not exceed 0,25 % of the actual volume for accuracy class
1 meters, and 0,5 % of the actual volume for accuracy c
...