Specification of environmental tests corresponding to environmental conditions given in Part 1
Inženiring opreme (EE) - Pogoji okolja in preskusi vplivov okolja za telekomunikacijsko opremo – Del 2-6: Specifikacija preskusov vplivov okolja - Ladijsko okolje
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST ETS 300 019-2-6:1999
01-november-1999
Inženiring opreme (EE) - Pogoji okolja in preskusi vplivov okolja za
telekomunikacijsko opremo – Del 2-6: Specifikacija preskusov vplivov okolja -
Ladijsko okolje
Equipment Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 2-6: Specification of environmental tests; Ship
environments
Ta slovenski standard je istoveten z: ETS 300 019-2-6 Edition 1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST ETS 300 019-2-6:1999 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ETS 300 019-2-6:1999
---------------------- Page: 2 ----------------------
SIST ETS 300 019-2-6:1999
EUROPEAN ETS 300 019-2-6
TELECOMMUNICATION May 1994
STANDARD
Source: ETSI TC-EE Reference: DE/EE-1019-2-6
ICS: 33.080
Environment, specification, equipment
Key words:
Equipment Engineering (EE);
Environmental conditions and environmental tests for
telecommunications equipment
Part 2-6: Specification of environmental tests
Ship environments
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1994. All rights reserved.
New presentation - see History box
---------------------- Page: 3 ----------------------
SIST ETS 300 019-2-6:1999
Page 2
ETS 300 019-2-6: May 1994
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.
---------------------- Page: 4 ----------------------
SIST ETS 300 019-2-6:1999
Page 3
ETS 300 019-2-6: May 1994
Contents
Foreword .5
1 Scope .7
2 Normative references.7
3 Environmental test specifications.7
3.1 Specification T 6.1: Totally weatherprotected locations.8
3.2 Specification T 6.2: Partly weatherprotected locations .10
3.3 Specification T 6.3: Non-weatherprotected locations .12
3.4 Notes to tables 1 to 5.16
Annex A (informative): Bibliography.17
History.18
---------------------- Page: 5 ----------------------
SIST ETS 300 019-2-6:1999
Page 4
ETS 300 019-2-6: May 1994
Blank page
---------------------- Page: 6 ----------------------
SIST ETS 300 019-2-6:1999
Page 5
ETS 300 019-2-6: May 1994
Foreword
This multi-part European Telecommunication Standard (ETS) has been produced by the Equipment
Engineering (EE) Technical Committee of the European Telecommunications Standards Institute (ETSI).
ETS 300 019 is concerned with environmental conditions and environmental tests for telecommunications
equipment and comprises two main parts, each with subdivisions:
- ETS 300 019-1: "Classification of environmental conditions".
Part 1 specifies different standardised environmental classes covering climatic and biological
conditions, chemically and mechanically active substances and mechanical conditions during
storage, transportation and in use.
- ETS 300 019-2: "Specification of environmental tests".
Part 2 specifies the recommended test severities and test methods for the different environmental
classes.
Part 2-0 forms a general overview of Part 2. This part, (Part 2-6), deals with ship environments.
---------------------- Page: 7 ----------------------
SIST ETS 300 019-2-6:1999
Page 6
ETS 300 019-2-6: May 1994
Blank page
---------------------- Page: 8 ----------------------
SIST ETS 300 019-2-6:1999
Page 7
ETS 300 019-2-6: May 1994
1 Scope
This European Telecommunication Standard (ETS) specifies test severities and methods for the
verification of the required resistibility of equipment according to the relevant environmental class.
The tests defined in Part 2-6 of this multi-part standard apply to the use of equipment installed
permanently or temporarily in ships and cover the environments and the vessels stated in
ETS 300 019-1-6 [1].
2 Normative references
This ETS incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications
apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest
edition of the publication referred to applies.
[1] ETS 300 019-1-6: "Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment Part 1-6: Classification
of environmental conditions; Ship environments".
[2] IEC 68-2: "Basic environmental testing procedures. Part 2: Tests".
[3] ETS 300 019-2-0: "Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment Part 2-0: Specification of
environmental tests; Introduction".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are given in Clauses 4 and 5 of
ETS 300 019-1-6 [1].
ETS 300 019-2-0 [3] forms a general overview of Part 2 of this ETS.
The equipment under test is assumed to be in its operational state throughout the test conditions
described in this Part unless otherwise stated. The required performance before, during and after the test
needs to be specified in the product specification. Input and load conditions of the equipment shall be
chosen to obtain full utilisation of the equipment under test. The heat dissipation shall be maximised,
except for the steady state, low temperature test, where it shall be minimised.
---------------------- Page: 9 ----------------------
SIST ETS 300 019-2-6:1999
Page 8
ETS 300 019-2-6: May 1994
3.1 Specification T 6.1: Totally weatherprotected locations
This specification applies to a totally weatherprotected use in ships excluding Warm Damp and Warm Damp Equable climates, see tables 1 and 4.
Table 1: Test specification T 6.1: Totally weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T 6.1: Ship, totally
Class 6.1 weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method
severity
low (°C) +5 +5 (4) 16 h IEC 68-2-1 Ab/Ad: Cold (3)
____________________________________________________________________________________________________________________________
high (°C) +40 +40 16 h IEC 68-2-2 Bb/Bd: Dry heat
____________________________________________________________________________________________________________________________
Air
temperature change air/water (°C) no
____________________________________________________________________________________________________________________________
surface high (°C) no
low (%) 10 (5)
______________________________________________________________________________________________________________
high; slow (%) 95 93 4 days IEC 68-2-56 Cb: Damp heat
relative temperature change (°C) +30 +30 steady state
______________________________________________________________________________________________________________
high; rapid (%) no
temperature change (°C)
____________________________________________________________________________________________________________________________
Humidity
3
absolute high; rapid (g/m)no
temperature change
Air speed (m/s) no
temperature high (°C) 30 none
_____________________________________________________________________________________________________________
low (°C) no
____________________________________________________________________________________________________________________________
Water intensity (mm/min) no
3
rain volume (m /min)
pressure (kPa)
____________________________________________________________________________________________________________________________
other sources velocity (m/s) no
____________________________________________________________________________________________________________________________
wetness no
2
Radiation solar (W/m)no
____________________________________________________________________________________________________________________________
2
heat (W/m)no
(continued)
---------------------- Page: 10 ----------------------
SIST ETS 300 019-2-6:1999
Table 1 (concluded): Test specification T 6.1: Totally weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T 6.1: Ship, totally
Class 6.1 weatherprotected locations
Type Parameter- Detail parameter- Characteristic Test severity Duration Reference Method
severity
3
SO2 (mg/m ) 0,1 (1) none (2)
sulphur _____________________________________________________________________________________________________________ _
3
H S (mg/m ) 0,01 (1) none (2)
2
____________________________________________________________________________________________________________________________
sea salts negligible
chlorine ______________________________________________________________________________________________________________
3
HCl (mg/m ) 0,1 (1) none (2)
____________________________________________________________________________________________________________________________
Chemically
3
active NO (mg/m ) 0,1 (1) none (2)
x
substances nitrogen ______________________________________________________________________________________________________________
3
NH (mg/m ) 0,3 (1) none (2)
3
____________________________________________________________________________________________________________________________
hydrogen
3
fluoride HF (mg/m ) 0,003 (1) none (2)
____________________________________________________________________________________________________________________________
3
ozone O (mg/m ) 0,01 (1) none (2)
3
dust sedimentation negligible
___________________________________________________________________________________________________________________________ _
Mechanically
active sand in air no
____________________________________________________________________________________________________________________________
substances
soot deposit no
Flora and micro organisms negligible
_____________________________________________________________________________________________________________________________
Fauna
rodents, insects negligible
no = this condition does not occur in this class. (n) = NOTE (n = number of note), see subclause 3.4.
none = verification is required only in special cases.
Page 9
ETS 300 019-2-6: May 1994
---------------------- Page: 11 ----------------------
SIST ETS 300 019-2-6:1999
Page 10
ETS 300 019-2-6: May 1994
3.2 Specification T 6.2: Partly weatherprotected locations
This specification applies to use in ships excluding Cold Climate and extreme weather conditions, see tables 2, 4 and 5.
Table 2: Test specification T 6.2: Partly weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T 6.2 : Ship, partly
Class 6.2 weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method
severity
low (°C) -25 -25 (4) 16 h IEC 68-2-1 Ab/Ad: Cold (3)
___________________________________________________________________________________________________________________________
high (°C) +70 +70 or +85 (7) 16 h IEC 68-2-2 Bb/Bd: Dry heat
___________________________________________________________________________________________________________________________
change gradual (°C) -25/+40 -25/+40 5 cycles IEC 68-2-14 Nb: Change of
Air (°C/min) 3 3 (6) t = 3 h temperature
1
___________________________________________________________________________________________________________________________
temperature
change air/water (°C) +40/+5 none (8)
___________________________________________________________________________________________________________________________
surface high (°C) +70 none
low (%) 10 none (5)
_____________________________________________________________________________________________________________
relative high; slow (%) 95 93 4 days IEC 68-2-56 Cb: Damp heat
temperature change (°C) +45 +40 steady state
_____________________________________________________________________________________________________________
high; rapid (%) 95 none (5)
temperature change (°C) -25/+35
___________________________________________________________________________________________________________________________
Humidity
3
high; rapid (g/m)60
absolute temperature change (°C) +70/+15
(%) 90-100 6 cycles IEC 68-2-30 Db: Damp heat
(°C) +55 cyclic, variant 1
Air speed m/s 30 none (5)
temperature high (°C) +35 none (5)
_____________________________________________________________________________________________________________
low (°C) freezing point none (5)
___________________________________________________________________________________________________________________________
intensity (mm/min) 6
3
rain volume (m /min) 0,01 5 minutes IEC 68-2-18 Rb: Impacting water
pressure (kPa) 90 method 2.2
Water ___________________________________________________________________________________________________________________________
other sources velocity (m/s) 3 none (5)
___________________________________________________________________________________________________________________________
wetness wet surfaces none (9)
2
Radiation solar (W/m ) 1120 none (10) (11)
___________________________________________________________________________________________________________________________
2
heat (W/m ) 1200 none (10)
(continued)
---------------------- Page: 12 ----------------------
SIST ETS 300 019-2-6:1999
Table 2 (concluded): Test specification T 6.2: Par
...
SLOVENSKI STANDARD
3SIST ETS 300 019-2-6:1999
01-VHSWHPEHU-1999
Inženiring opreme (EE) - Pogoji okolja in preskusi vplivov okolja za
telekomunikacijsko opremo – Del 2-6: Specifikacija preskusov vplivov okolja -
Ladijsko okolje
Equipment Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 2-6: Specification of environmental tests; Ship
environments
Ta slovenski standard je istoveten z: ETS 300 019-2-6 E1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.020 Telekomunikacije na splošno Telecommunications in
general
3SIST ETS 300 019-2-6:1999 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ETS 300 019-2-6:1999
---------------------- Page: 2 ----------------------
SIST ETS 300 019-2-6:1999
EUROPEAN ETS 300 019-2-6
TELECOMMUNICATION May 1994
STANDARD
Source: ETSI TC-EE Reference: DE/EE-1019-2-6
ICS: 33.080
Environment, specification, equipment
Key words:
Equipment Engineering (EE);
Environmental conditions and environmental tests for
telecommunications equipment
Part 2-6: Specification of environmental tests
Ship environments
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1994. All rights reserved.
New presentation - see History box
---------------------- Page: 3 ----------------------
SIST ETS 300 019-2-6:1999
Page 2
ETS 300 019-2-6: May 1994
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.
---------------------- Page: 4 ----------------------
SIST ETS 300 019-2-6:1999
Page 3
ETS 300 019-2-6: May 1994
Contents
Foreword .5
1 Scope .7
2 Normative references.7
3 Environmental test specifications.7
3.1 Specification T 6.1: Totally weatherprotected locations.8
3.2 Specification T 6.2: Partly weatherprotected locations .10
3.3 Specification T 6.3: Non-weatherprotected locations .12
3.4 Notes to tables 1 to 5.16
Annex A (informative): Bibliography.17
History.18
---------------------- Page: 5 ----------------------
SIST ETS 300 019-2-6:1999
Page 4
ETS 300 019-2-6: May 1994
Blank page
---------------------- Page: 6 ----------------------
SIST ETS 300 019-2-6:1999
Page 5
ETS 300 019-2-6: May 1994
Foreword
This multi-part European Telecommunication Standard (ETS) has been produced by the Equipment
Engineering (EE) Technical Committee of the European Telecommunications Standards Institute (ETSI).
ETS 300 019 is concerned with environmental conditions and environmental tests for telecommunications
equipment and comprises two main parts, each with subdivisions:
- ETS 300 019-1: "Classification of environmental conditions".
Part 1 specifies different standardised environmental classes covering climatic and biological
conditions, chemically and mechanically active substances and mechanical conditions during
storage, transportation and in use.
- ETS 300 019-2: "Specification of environmental tests".
Part 2 specifies the recommended test severities and test methods for the different environmental
classes.
Part 2-0 forms a general overview of Part 2. This part, (Part 2-6), deals with ship environments.
---------------------- Page: 7 ----------------------
SIST ETS 300 019-2-6:1999
Page 6
ETS 300 019-2-6: May 1994
Blank page
---------------------- Page: 8 ----------------------
SIST ETS 300 019-2-6:1999
Page 7
ETS 300 019-2-6: May 1994
1 Scope
This European Telecommunication Standard (ETS) specifies test severities and methods for the
verification of the required resistibility of equipment according to the relevant environmental class.
The tests defined in Part 2-6 of this multi-part standard apply to the use of equipment installed
permanently or temporarily in ships and cover the environments and the vessels stated in
ETS 300 019-1-6 [1].
2 Normative references
This ETS incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications
apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest
edition of the publication referred to applies.
[1] ETS 300 019-1-6: "Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment Part 1-6: Classification
of environmental conditions; Ship environments".
[2] IEC 68-2: "Basic environmental testing procedures. Part 2: Tests".
[3] ETS 300 019-2-0: "Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment Part 2-0: Specification of
environmental tests; Introduction".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are given in Clauses 4 and 5 of
ETS 300 019-1-6 [1].
ETS 300 019-2-0 [3] forms a general overview of Part 2 of this ETS.
The equipment under test is assumed to be in its operational state throughout the test conditions
described in this Part unless otherwise stated. The required performance before, during and after the test
needs to be specified in the product specification. Input and load conditions of the equipment shall be
chosen to obtain full utilisation of the equipment under test. The heat dissipation shall be maximised,
except for the steady state, low temperature test, where it shall be minimised.
---------------------- Page: 9 ----------------------
SIST ETS 300 019-2-6:1999
Page 8
ETS 300 019-2-6: May 1994
3.1 Specification T 6.1: Totally weatherprotected locations
This specification applies to a totally weatherprotected use in ships excluding Warm Damp and Warm Damp Equable climates, see tables 1 and 4.
Table 1: Test specification T 6.1: Totally weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T 6.1: Ship, totally
Class 6.1 weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method
severity
low (°C) +5 +5 (4) 16 h IEC 68-2-1 Ab/Ad: Cold (3)
____________________________________________________________________________________________________________________________
high (°C) +40 +40 16 h IEC 68-2-2 Bb/Bd: Dry heat
____________________________________________________________________________________________________________________________
Air
temperature change air/water (°C) no
____________________________________________________________________________________________________________________________
surface high (°C) no
low (%) 10 (5)
______________________________________________________________________________________________________________
high; slow (%) 95 93 4 days IEC 68-2-56 Cb: Damp heat
relative temperature change (°C) +30 +30 steady state
______________________________________________________________________________________________________________
high; rapid (%) no
temperature change (°C)
____________________________________________________________________________________________________________________________
Humidity
3
absolute high; rapid (g/m)no
temperature change
Air speed (m/s) no
temperature high (°C) 30 none
_____________________________________________________________________________________________________________
low (°C) no
____________________________________________________________________________________________________________________________
Water intensity (mm/min) no
3
rain volume (m /min)
pressure (kPa)
____________________________________________________________________________________________________________________________
other sources velocity (m/s) no
____________________________________________________________________________________________________________________________
wetness no
2
Radiation solar (W/m)no
____________________________________________________________________________________________________________________________
2
heat (W/m)no
(continued)
---------------------- Page: 10 ----------------------
SIST ETS 300 019-2-6:1999
Table 1 (concluded): Test specification T 6.1: Totally weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T 6.1: Ship, totally
Class 6.1 weatherprotected locations
Type Parameter- Detail parameter- Characteristic Test severity Duration Reference Method
severity
3
SO2 (mg/m ) 0,1 (1) none (2)
sulphur _____________________________________________________________________________________________________________ _
3
H S (mg/m ) 0,01 (1) none (2)
2
____________________________________________________________________________________________________________________________
sea salts negligible
chlorine ______________________________________________________________________________________________________________
3
HCl (mg/m ) 0,1 (1) none (2)
____________________________________________________________________________________________________________________________
Chemically
3
active NO (mg/m ) 0,1 (1) none (2)
x
substances nitrogen ______________________________________________________________________________________________________________
3
NH (mg/m ) 0,3 (1) none (2)
3
____________________________________________________________________________________________________________________________
hydrogen
3
fluoride HF (mg/m ) 0,003 (1) none (2)
____________________________________________________________________________________________________________________________
3
ozone O (mg/m ) 0,01 (1) none (2)
3
dust sedimentation negligible
___________________________________________________________________________________________________________________________ _
Mechanically
active sand in air no
____________________________________________________________________________________________________________________________
substances
soot deposit no
Flora and micro organisms negligible
_____________________________________________________________________________________________________________________________
Fauna
rodents, insects negligible
no = this condition does not occur in this class. (n) = NOTE (n = number of note), see subclause 3.4.
none = verification is required only in special cases.
Page 9
ETS 300 019-2-6: May 1994
---------------------- Page: 11 ----------------------
SIST ETS 300 019-2-6:1999
Page 10
ETS 300 019-2-6: May 1994
3.2 Specification T 6.2: Partly weatherprotected locations
This specification applies to use in ships excluding Cold Climate and extreme weather conditions, see tables 2, 4 and 5.
Table 2: Test specification T 6.2: Partly weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T 6.2 : Ship, partly
Class 6.2 weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method
severity
low (°C) -25 -25 (4) 16 h IEC 68-2-1 Ab/Ad: Cold (3)
___________________________________________________________________________________________________________________________
high (°C) +70 +70 or +85 (7) 16 h IEC 68-2-2 Bb/Bd: Dry heat
___________________________________________________________________________________________________________________________
change gradual (°C) -25/+40 -25/+40 5 cycles IEC 68-2-14 Nb: Change of
Air (°C/min) 3 3 (6) t = 3 h temperature
1
___________________________________________________________________________________________________________________________
temperature
change air/water (°C) +40/+5 none (8)
___________________________________________________________________________________________________________________________
surface high (°C) +70 none
low (%) 10 none (5)
_____________________________________________________________________________________________________________
relative high; slow (%) 95 93 4 days IEC 68-2-56 Cb: Damp heat
temperature change (°C) +45 +40 steady state
_____________________________________________________________________________________________________________
high; rapid (%) 95 none (5)
temperature change (°C) -25/+35
___________________________________________________________________________________________________________________________
Humidity
3
high; rapid (g/m)60
absolute temperature change (°C) +70/+15
(%) 90-100 6 cycles IEC 68-2-30 Db: Damp heat
(°C) +55 cyclic, variant 1
Air speed m/s 30 none (5)
temperature high (°C) +35 none (5)
_____________________________________________________________________________________________________________
low (°C) freezing point none (5)
___________________________________________________________________________________________________________________________
intensity (mm/min) 6
3
rain volume (m /min) 0,01 � 5 minutes IEC 68-2-18 Rb: Impacting water
pressure (kPa) 90 method 2.2
Water ___________________________________________________________________________________________________________________________
other sources velocity (m/s) 3 none (5)
___________________________________________________________________________________________________________________________
wetness wet surfaces none (9)
2
Radiation solar (W/m ) 1120 none (10) (11)
___________________________________________________________________________________________________________________________
2
heat (W/m ) 1200 none (10)
(continued)
---------------------- Page: 12 ----------------------
SIST ETS 300 019-2-6:1999
Table 2 (concluded): Test specification T 6.2: Partly weatherprotected loca
...
Questions, Comments and Discussion