Abstract

To produce a PICS proforma for Direct Mode Operation of Mobile terminals

Status
Published
Publication Date
30-Nov-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2003
Due Date
01-Dec-2003
Completion Date
01-Dec-2003
Mandate
BC-T-344
Mandate
T-172

Buy Documents

Standard

SIST ETS 300 396-8-1 E1:2003

English language (40 pages)
Preview
Preview
e-Library read for
×1 day

SIST ETS 300 396-8-1 E1:2003 is the Slovenian adoption of the ETSI standard for Terrestrial Trunked Radio (TETRA) Direct Mode Operation (DMO). It specifies a Protocol Implementation Conformance Statement (PICS) proforma for the Mobile Station to Mobile Station (MS-MS) Air Interface (AI) protocol, so a supplier can declare which DMO capabilities an implementation supports. Engineers, testers, quality teams, and buyers use it to describe and compare conformance in a standard format.

What does SIST ETS 300 396-8-1 E1:2003 specify?

SIST ETS 300 396-8-1 E1:2003 specifies the PICS proforma for the TETRA DMO MS-MS AI protocol defined in ETS 300 396-3. In practice, it is the questionnaire and completion rules used to record what a mobile implementation supports, and it is structured so that the answers can be checked consistently.

The document is organized into four main clauses and one normative annex:

PartWhat it covers
Clause 1Scope
Clause 2Normative references
Clause 3Definitions and abbreviations
Clause 4Conformance to the PICS proforma specification
Annex ANormative Protocol ICS proforma (PICS) for ETS 300 396-3

Annex A is the core of the document. It contains the actual proforma plus guidance for completion, identification fields, protocol identification, a global conformance statement, and separate sections for the DMCC and DLL parts of the protocol stack.

What are the key requirements of SIST ETS 300 396-8-1 E1:2003?

How the PICS must be completed

SIST ETS 300 396-8-1 E1:2003 requires the completed PICS to be technically equivalent to the proforma in Annex A, with the same numbering, names, and ordering. That matters because a conformance claim only works if different suppliers answer the same questions in the same way.

Annex A also requires explicit answers in the support fields and uses standard status codes such as mandatory, optional, not applicable, prohibited, qualified optional, and conditional. For a reader, this means the form is not free text - it is a structured declaration of support.

The guidance explains how to handle multiple-profile support and conditional answers, and it notes that support for a received PDU implies the ability to parse all valid parameters of that PDU. In practice, that prevents a supplier from claiming reception of a message without handling its defined contents.

What the document asks you to declare about the implementation

Annex A starts with identification of the Implementation Under Test (IUT), the System Under Test (SUT), the product supplier, and the contact person. This is the administrative part that ties the declaration to a specific product build and test environment.

Clause A.3 links the proforma to ETS 300 396-3 and separates the answers into the DMCC layer 3 part and the DLL layer 2 part. Clause A.4 then asks whether all mandatory capabilities of DMCC and DLL are implemented; a negative answer means non-conformance for that part.

What DMCC capability areas are covered

The DMCC section in A.5 asks the supplier to declare support for the major service families: circuit mode call and Short Data Service (SDS). At least one of these service families must be supported.

For circuit mode call, the proforma covers group and individual addressing, call set-up with or without presence check, call acceptance, end of call transmission, pre-emption, change-over, late entry, TPNI handling, and inter-MNI call behavior. In practice, this tells a buyer or test lab which kinds of calls the mobile can originate, accept, and terminate.

For circuit mode services, the form asks about speech, different data protection levels, clear or end-to-end encrypted transmission, and call priority types. That matters because these choices affect how the terminal behaves in operational, emergency, and data-bearing calls.

What SDS capability areas are covered

The SDS part of A.5 covers sending and receiving short data, extended error protection using FCS, and the choice between group and individual addressing. It also distinguishes pre-defined short data messages from user-defined short data, plus OTAR and enable/disable functions.

The data transmission tables then ask how short data is sent, including on a free channel, after pre-emption, or by stealing from circuit mode transmission. For a user, this shows whether the implementation can move short messages under normal and congested radio conditions.

The user-defined data section requires the supplier to declare which data sizes are supported. The PICS also includes separate PDU tables for DM-SDS UDATA, DM-SDS DATA, and DM-SDS ACK, so implementers must state whether they send and receive the corresponding messages and fields.

What DLL and MAC declarations cover

The DLL section in A.6 focuses on the Data Link Layer and its DM-Medium Access Control (MAC) features. It covers scrambling, PDU error detection, stealing mechanisms, DM channel usage, signalling messages, and traffic mode procedures.

A series of tables then lists MAC PDUs, their information elements, generated messages, and related procedures. For implementation teams, this is the part that ties the radio behavior to the actual layer 2 message flow and channel handling.

The annex also includes constants and timers for DMCC and DM-MAC. These tables require the supplier to report supported values or ranges where applicable, which is important for test planning because timeouts and retry behavior affect interoperability and conformance results.

What terms does SIST ETS 300 396-8-1 E1:2003 define?

  • Implementation Conformance Statement (ICS) - A supplier statement saying which capabilities of an implementation are supported against a given specification.
  • ICS proforma - A questionnaire-style document that becomes an ICS when it is completed for a specific implementation.
  • Protocol ICS (PICS) - An ICS that applies to a protocol specification rather than to a broader product profile.
  • Implementation Under Test (IUT) - The implementation being assessed for conformance.
  • System Under Test (SUT) - The system in which the IUT resides during the conformance exercise.
  • Direct Mode Operation (DMO) - The TETRA operating mode covered here, where mobile terminals communicate directly.
  • Direct Mode Call Control (DMCC) - The layer 3 part of the DMO protocol stack that handles call and short data control.
  • Data Link Layer (DLL) - The layer 2 part of the DMO protocol stack that handles MAC behavior and related PDUs.

Who uses SIST ETS 300 396-8-1 E1:2003?

SIST ETS 300 396-8-1 E1:2003 is used by suppliers of TETRA mobile terminals and by teams preparing conformance documentation for DMO products. Test laboratories use it to structure protocol checks, and conformance assessors use it to compare declared support with observed behavior.

It is also useful for quality managers and buyers who need a clear view of which DMO features a product claims to implement, especially when comparing terminal support for circuit mode, SDS, and MAC behavior.

Which standards are used with SIST ETS 300 396-8-1 E1:2003?

  • ETS 300 396-3 - Defines the TETRA DMO MS-MS AI protocol that this PICS proforma applies to.
  • ETS 300 406 - Provides the testing and specification methodology used for protocol and profile conformance testing.
  • ISO/IEC 9646-1 - Supplies the general conformance testing concepts and framework.
  • ISO/IEC 9646-7 - Gives the rules for Implementation Conformance Statements and the form of PICS proformas.

What does the SIST ETS 300 396-8-1 E1:2003 document contain?

The document contains completion guidance, identification fields, a global conformance statement, and detailed tables for DMCC and DLL conformance declarations. The tables cover services, protocol features, PDUs, PDU parameters, generated messages, constants, and timers.

Annex A is the practical heart of the document. It gives the structured questions that a supplier answers for a specific implementation, so the result can be used in testing, procurement, or conformance review.

The annex is detailed enough to distinguish send and receive capability, call setup variants, short data addressing modes, PDU contents, and timing-related behavior. That makes it suitable for documenting exactly how a TETRA DMO mobile behaves at the protocol level.

Buy Documents

Standard

SIST ETS 300 396-8-1 E1:2003

English language (40 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST ETS 300 396-8-1 E1:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8: Protocol Implementation Conformance Statement (PICS) proforma specification; Sub-part 1: Mobile Station to Mobile Station (MS-MS) Air Interface (AI)". This standard covers: To produce a PICS proforma for Direct Mode Operation of Mobile terminals

To produce a PICS proforma for Direct Mode Operation of Mobile terminals

SIST ETS 300 396-8-1 E1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.070.10 - Terrestrial Trunked Radio (TETRA). The ICS classification helps identify the subject area and facilitates finding related standards.

SIST ETS 300 396-8-1 E1:2003 is associated with the following European legislation: Standardization Mandates: BC-T-344, T-172. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST ETS 300 396-8-1 E1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Definitions and abbreviations
  • 3.1 Definitions
  • 3.2 Abbreviations
  • 4 Conformance to this Protocol Implementation Conformance Statement
  • Annex A (normative): Protocol ICS proforma (PICS) for ETS 300 396-3
  • 1 Group address call capability
  • 4 Initiate call set-up with presence 6.2.2.1 o
  • 6 Accept call set-up with presence 6.2.2.2 o
  • 8 Receive end of call transmission 6.2.4.2 m
  • 10 Receive call termination 6.2.4.2, 6.2.5.2 m
  • 13 Initiate a new call by pre-emption 6.2.6 o
  • 14 Initiate call change-over 6.2.5.2 o
  • 16 Late entry by called party 6.2.3.2 o
  • 18 Suppress TPNI in call setup 6.2.4.3 o
  • 20 Initiate inter-MNI call 6.2.4.3 o
  • 1 Group call address 6.2.1.1 m
  • 2 Call on temporary group address 6.2.1.3 o
  • 11 Normal priority call 5.4 m
  • 12 High priority call 5.4 o
  • 13 Pre-emptive priority call 5.4 o
  • 14 Emergency pre-emptive priority call 5.4 o
  • 15 Recent user priority service 5.4 o
  • 3 Extended error protection (Frame 6.3.4 m
  • 3 Including data in ACK 6.3 o
  • 1 Send short data on a free channel 6.3.1.1 m
  • 2 Linearization Channel (LCH) in m
  • 9.6.5 frame3flag
  • 3 Pre-emption flag 9.6.10 m
  • 5 Power control flag m
  • 9.6.9 6 Reserved m
  • 9.5.1 7 Circuit mode type 9.6.3 m
  • 8 Reserved 9.5.1 m
  • 10 End-to-end encryption flag 9.7.8 m
  • 13 Reserved
  • 1 Reserved 9.5.2 m
  • 2 Power class 9.6.8 m
  • 5 Circuit mode type m
  • 9.6.3 6 Reserved 9.5.2 m
  • 7 Priority level 9.6.11 m
  • 9 Call type flag
  • 10 External source flag 9.7.9 m
  • 11 Reserved 9.5.2 m
  • 2 Reserved 9.5.3 m
  • 1 Disconnect cause m
  • 9.7.7 A.5.10.5 DM-CONNECT ACK
  • 2 LCHinframe3flag 9.6.5 m
  • 3 Pre-emption flag 9.6.10 m
  • 4 Power class 9.6.8 m
  • 5 Power control flag 9.6.9 m
  • 7 Circuit mode type 9.6.3 m
  • 8 Reserved 9.5.5 m
  • 9 Priority level 9.6.11 m
  • 10 End-to-end encryption flag
  • 11 Call type flag 9.7.5 m
  • 12 External source flag 9.7.9 m
  • 2 LCHinframe3flag m
  • 9.6.5 3 Pre-emption flag 9.6.10 m
  • 4 Power class 9.6.8 m
  • 7 Circuit mode type m
  • 9.6.3 8 Reserved 9.5.6 m
  • 9 Priority level 9.6.11 m
  • 11 Call type flag
  • 12 External source flag 9.7.9 m
  • 13 Reserved 9.5.6 m
  • 3 Requests flag m
  • 9.6.14 4 Changeover requests flag 9.6.1 m
  • 5 Requests bitmap 9.6.13 m
  • 8 Timing adjustment m
  • 9.6.19 9 Priority level 9.6.11 m
  • 10 Cease cause 9.7.6 m
  • 2 Timing adjustment m
  • 9.6.19 3 Priority level 9.6.11 m
  • 1 Timing change announced 9.6.20 m
  • 3 Timing adjustment m
  • 9.6.19 4 New call pre-emption 9.6.6 m
  • 5 Type of pre-emption 9.6.23 m
  • 3 New call pre-emption 9.6.6 m

Introduction

To evaluate conformance of a particular implementation, it is necessary to have a statement of which capabilities and options have been implemented for a telecommunication specification. Such a statement is called an Implementation Conformance Statement (ICS).

SIST ETS 300 396-8-1 E1:2003 Page 6 ETS 300 396-8-1: January 2000 Blank page

SIST ETS 300 396-8-1 E1:2003 Page 7 ETS 300 396-8-1: January 2000

1 Scope

This European Telecommunication Standard (ETS) provides the Protocol Implementation Conformance Statement (PICS) proforma for the TETRA Direct Mode Operation (DMO), Mobile Station to Mobile Station (MS-MS) Air Interface (AI) protocol, defined in ETS 300 396-3 [1] in compliance with the relevant requirements, and in accordance with the relevant guidance given in ISO/IEC 9646-7 [4] and ETS 300 406 [2].

2 Normative references

This ETS incorporates by dated and undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies.

[1] ETS 300 396-3 (1998): "Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 3: Mobile Station to Mobile Station (MS-MS) Air Interface (AI) protocol".

[2] ETS 300 406 (1995): "Methods for Testing and Specification (MTS); Protocol and profile conformance testing specifications; Standardization methodology". [3] ISO/IEC 9646-1 (1994): "Information technology; Open systems interconnection; Conformance testing methodology and framework; Part 1: General concepts". [4] ISO/IEC 9646-7 (1995): "Information technology; Open Systems Interconnection; Conformance testing methodology and framework; Part 7:

Implementation Conformance Statements".

3 Definitions and abbreviations

3.1 Definitions

For the purposes of this ETS, the following definitions apply:

  • terms defined in ETS 300 396-3 [1];
  • terms defined in ISO/IEC 9646-1 [3] and in ISO/IEC 9646-7 [4]. In particular, the following terms defined in ISO/IEC 9646-1 [3] apply:

Implementation Conformance Statement (ICS): statement made by the supplier of an implementation or system claimed to conform to a given specification, stating which capabilities have been implemented. The ICS can take several forms: protocol ICS, profile ICS, profile specific ICS, information object ICS, etc. ICS proforma: document, in the form of a questionnaire, which when completed for an implementation or system becomes an ICS Protocol ICS (PICS): ICS for an implementation or system claimed to conform to a given protocol specification

SIST ETS 300 396-8-1 E1:2003 Page 8 ETS 300 396-8-1: January 2000

3.2 Abbreviations

For the purposes of this ETS, the following abbreviations apply:

AI Air Interface DLL Data Link Layer DM Direct Mode DMCC Direct Mode Call Control DMO Direct Mode Operation FCS Frame Check Sequence ICS Implementation Conformance Statement IUT Implementation Under Test LCH Linearization Channel MAC Medium Access Control OTAR Over The Air Re-keying PDU Protocol Data Unit PICS Protocol Implementation Conformance Statement SCH Signalling Channel SCS System Conformance Statement SDS Short Data Service SDU Service Data Unit SUT System Under Test TPNI Transmitting Party Number Identification TSI TETRA Subscriber Identity

4 Conformance to this Protocol Implementation Conformance Statement

(PICS) proforma specification If it claims to conform to this ETS, the actual PICS proforma to be filled in by a supplier shall be technically equivalent to the text of the PICS proforma given in annex A, and shall preserve the numbering/naming and ordering of the proforma items.

A PICS which conforms to this ETS shall be a conforming PICS proforma completed in accordance with the guidance for completion given in clause A.1.

SIST ETS 300 396-8-1 E1:2003 Page 9 ETS 300 396-8-1: January 2000

Annex A (normative): Protocol ICS proforma (PICS) for ETS 300 396-3

Notwithstanding the provisions of the copyright clause related to the text of this ETS, ETSI grants that users of this ETS may freely reproduce the PICS proforma in this annex so that it can be used for its intended purposes and may further publish the completed PICS.

A.1 Guidance for completing the PICS proforma A.1.1 Purposes and structure The purpose of this PICS proforma is to provide a mechanism whereby a supplier of an implementation of the requirements defined in ETS 300 396-3 may provide information about the implementation in a standardized manner.

The PICS proforma is subdivided into subclauses for the following categories of information:

  • guidance for completing the PICS proforma;
  • identification of the implementation;
  • identification of the protocol;
  • global statement of conformance;
  • Direct Mode Call Control (DMCC) protocol layer 3 part:
  • circuit mode calls;
  • short data service;
  • Data Link Layer (DLL) protocol layer 2 part.

A.1.2 Abbreviations and conventions The PICS proforma contained in this annex is comprised of information in tabular form in accordance with the guidelines presented in ISO/IEC 9646-7.

Item column The item column contains a number which identifies the item in the table. Item description column The item description column describes in free text each respective item (e.g. parameters, timers, etc.). It implicitly means "is <item description> supported by the implementation?". Status column The following notations, defined in ISO/IEC 9646-7, are used for the status column:

m mandatory - the capability is required to be supported; o optional - the capability may be supported or not; n/a not applicable - in the given context, it is impossible to use the capability; x prohibited (excluded) - there is a requirement not to use this capability in the given context; o.i qualified optional - for mutually exclusive or selectable options from a set. "i" is an integer which identifies an unique group of related optional items and the logic of their selection which is defined immediately following the table;

SIST ETS 300 396-8-1 E1:2003 Page 10 ETS 300 396-8-1: January 2000 ci conditional - the requirement on the capability ("m", "o", "x" or "n/a") depends on the support of other optional or conditional items. "i" is an integer identifying a unique conditional status expression which is defined immediately following the table.

Reference column The reference column makes reference to ETS 300 396-3, except where explicitly stated otherwise. Support column The support column shall be filled in by the supplier of the implementation. The following common notations, defined in ISO/IEC 9646-7, are used for the support column:

Y or y supported by the implementation; N or n not supported by the implementation; N/A, n/a or - no answer required (allowed only if the status is n/a, directly or after evaluation of a conditional status).

If this PICS proforma is completed in order to describe a multiple-profile support in a system, it is necessary to be able to answer that a capability is supported for one profile and not supported for another. In that case, the supplier shall enter the unique reference to a conditional expression, preceded by "?" (e.g. ?3). This expression shall be given in the space for comments provided at the bottom of the table. It uses predicates defined in the System Conformance Statement (SCS), each of which refers to a single profile and which takes the value TRUE if and only if that profile is to be used. EXAMPLE 1: ?3: IF prof1 THEN Y ELSE N It is also possible to provide a comment to an answer in the space provided at the bottom of the table. NOTE: As stated in ISO/IEC 9646-7, support for a received Protocol Data Unit (PDU) requires the ability to parse all valid parameters of that PDU. Supporting a PDU while having no ability to parse a valid parameter is non-conformant. Support for a parameter on a PDU means that the semantics of that parameter is supported.

Values allowed column The values allowed column contains the type, the list, the range, or the length of values allowed. The following notations are used:

  • range of values: <min value> ... <max. value> example: 5 ... 20
  • list of values: <value1>, <value2>, ........, <valueN> example: 2, 4, 6, 8, 9 example: '1101'B, '1011'B, '1111'B example: '0A'H, '34'H, '2F'H
  • list of named values: <name1>(<val1>), <name2>(<val2>), ..., <nameN>(<valN> example: reject(1), accept(2)
  • length: size (<min size> ... <max size>) example: size (1 ... 8) Values supported column The values supported column shall be filled in by the supplier of the implementation. In this column, the values or the ranges of values supported by the implementation shall be indicated.

SIST ETS 300 396-8-1 E1:2003 Page 11 ETS 300 396-8-1: January 2000 References to items For each possible item answer (answer in the support column) within the PICS proforma a unique reference exists, used, for example, in the conditional expressions. It is defined as the table identifier, followed by a solidus character "/", followed by the item number in the table. If there is more than one support column in a table, the columns are discriminated by letters (a, b, etc.), respectively. EXAMPLE 2: A.5/4 is the reference to the answer of item 4 in table 5 of annex A. EXAMPLE 3: A.6/3b is the reference to the second answer (i.e. in the second support column) of item 3 in table 6 of annex A.

Prerequisite line A prerequisite line takes the form: Prerequisite: <predicate>. A prerequisite line after a clause or table title indicates that the whole clause or the whole table is not required to be completed if the predicate is FALSE.

A.1.3 Instructions for completing the PICS proforma The supplier of the implementation shall complete the PICS proforma in each of the spaces provided. In particular, an explicit answer shall be entered, in each of the support or supported column boxes provided, using the notation described in subclause A.1.2.

If necessary, the supplier may provide additional comments in space at the bottom of the tables, or separately on sheets of paper.

More detailed instructions are given at the beginning of the different subclauses of the PICS proforma. A.2 Identification of the implementation Identification of the Implementation Under Test (IUT) and the system in which it resides (the System Under Test (SUT)) should be filled in so as to provide as much detail as possible regarding version numbers and configuration options.

The product supplier information and client information should both be filled in if they are different. A person who can answer queries regarding information supplied in the PICS should be named as the contact person.

A.2.1 Date of the statement A.2.2 IUT identification IUT name:

IUT version:

A.2.3 SUT identification SUT name:

Hardware configuration:

SIST ETS 300 396-8-1 E1:2003 Page 12 ETS 300 396-8-1: January 2000 Operating system:

A.2.4 Product supplier Name:

Address:

Telephone number:

Facsimile number:

E-mail address:

Additional information:

A.2.5 Client (if different from product supplier) Name:

Address:

Telephone number:

Facsimile number:

E-mail address:

Additional information:

A.2.6 PICS contact person (A person to contact if there are any queries concerning the content of the PICS) Name:

Telephone number:

Facsimile number:

E-mail address:

SIST ETS 300 396-8-1 E1:2003 Page 13 ETS 300 396-8-1: January 2000 Additional information:

A.3 Identification of the protocol This PICS proforma applies to the following standard:

ETS 300 396-3 (1998): "Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 3: Mobile Station to Mobile Station (MS-MS) Air Interface (AI) protocol". This ETS contains two layers of the protocol stack, DMCC at layer 3 and Data Link Layer (DLL) at layer 2. Each layer is addressed in a different section of the present PICS. When submitting an implementation for test, the implementer is required to answer the questions of the section(s) of the proforma pertaining to the part(s) of the protocol submitted to the test, i.e. the DMCC section or the DLL one or both. A.4 Global statement of conformance Are all mandatory capabilities of DMCC implemented? (Yes/No/(n/a)). Are all mandatory capabilities of DLL implemented? (Yes/No/(n/a)). NOTE: Answering "No" to any of these questions indicates non-conformance to the protocol specification. Non-supported mandatory capabilities are to be identified in the PICS, with an explanation of why the implementation is non-conforming, on pages attached to the PICS proforma. Answering "n/a" to any of these two questions indicates that the questions related to that protocol does not apply.

A.5 DMCC at layer 3 A.5.1 DMCC major capabilities The supplier of the implementation shall state the support of the implementation for each of the following protocol services, in table A.1.

Table A.1: DMCC services Item Service Reference Status Support 1 Circuit mode call 6.2, 4.4 o.1 2 Short Data Service (SDS) 6.3, 4.4 o.1 o.1: It is mandatory to support at least one of these items A.5.2 Circuit mode call The supplier of the implementation shall state the support of the implementation for each of the following circuit mode call protocol features, in table A.2.

SIST ETS 300 396-8-1 E1:2003 Page 14 ETS 300 396-8-1: January 2000 Table A.2: Circuit mode protocol features Prerequisite: A.1/1 -- circuit mode call Item Protocol features Reference Status Support 5.2 o.2

1 Group address call capability

2 Individual address call capability 5.2 o.2 Initiate call set-up without presence 6.2.1.1 o

check

4 Initiate call set-up with presence 6.2.2.1 o

check Accept call set-up without presence 6.2.1.2 m

check

6 Accept call set-up with presence 6.2.2.2 o

check Master end of call transmission 6.2.4.1 c201

8 Receive end of call transmission 6.2.4.2 m

9 Master call termination 6.2.4.1, 6.2.5.1 c201

10 Receive call termination 6.2.4.2, 6.2.5.2 m

11 Accept call pre-emption 6.2.4.1, 6.2.5.1 c201 Initiate pre-emption in ongoing call 6.2.4.2, 6.2.5.3 o

13 Initiate a new call by pre-emption 6.2.6 o

14 Initiate call change-over 6.2.5.2 o

15 Accept call change-over 6.2.5.1 c201

16 Late entry by called party 6.2.3.2 o

Receive Transmitting Party Number 6.2.4.3 m

Identification (TPNI) in call setup

18 Suppress TPNI in call setup 6.2.4.3 o

Receive inter-MNI call 6.2.4.3 m

20 Initiate inter-MNI call 6.2.4.3 o

o.2: It is mandatory to support at least one of these items c201: IF A.2/3 OR A.2/4 -- If initiation of call set-up with or without presence check supported THEN m -- then mandatory ELSE n/a A.5.3 Circuit mode call set-up The supplier of the implementation shall state the support of the implementation for each of the following circuit mode call set-up procedures, in tables A.3 to A.4.

Table A.3: Circuit mode call set-up procedures - Group call Prerequisite: A.2/1 AND A.2/3 -- Initiate group call set-up Item Set-up procedure Reference Status Support

1 Group call address 6.2.1.1 m

2 Call on temporary group address 6.2.1.3 o

SIST ETS 300 396-8-1 E1:2003 Page 15 ETS 300 396-8-1: January 2000 Table A.4: Circuit mode call set-up procedures - Individual call Prerequisite: A.2/2 -- Individual address call capability Item Set-up procedure Reference Status Support Initiate Individual call without presence 6.2.1.1 c401

check 2 Initiate Individual call with presence check 6.2.2.1 c402 c401: IF A.2/3 THEN o ELSE n/a -- If initiate call set-up without presence check then optional c402: IF A.2/4 THEN m ELSE n/a -- If initiate call set-up with presence check then mandatory A.5.4 Circuit mode services offered The supplier of the implementation shall state the support of the implementation for each of the following circuit mode services, in table A.5.

Table A.5: Circuit mode services offered Prerequisite: A.1/1 -- circuit mode call Item Circuit mode service Reference Status Support 1 Circuit mode speech: 5.4 o.3

Circuit mode data unprotected: 7.2 5.4 o.3 3 Circuit mode data low protection: 4.8, N=1 5.4 o.3 4 Circuit mode data low protection: 4.8, N=4 5.4 o.3 5 Circuit mode data low protection: 4.8, N=8 5.4 o.3 6 Circuit mode data high protection: 2.4, N=1 5.4 o.3 7 Circuit mode data high protection: 2.4, N=4 5.4 o.3

Circuit mode data high protection: 2.4, N=8 5.4 o.3 9 Clear end-to-end transmission 5.4 o.4 10 End to end encrypted transmission 5.4 o.4

11 Normal priority call 5.4 m

12 High priority call 5.4 o

13 Pre-emptive priority call 5.4 o

14 Emergency pre-emptive priority call 5.4 o

15 Recent user priority service 5.4 o

o.3: It is mandatory to support at least one of these items o.4: It is mandatory to support at least one of these items A.5.5 Short data services The supplier of the implementation shall state the support of the implementation for each of the following short data services, in table A.6.

Table A.6: Short data services Prerequisite: A.1/2 -- Short Data Services Item Short data service Reference Status Support 1 Send data (note 1) 6.3.1 o.5 Receive data (note 2) 6.3.2 o.5

3 Extended error protection (Frame 6.3.4 m

Check Sequence (FCS)) NOTE 1: Capability to originate short data transaction as master. NOTE 2: Capability to receive short data transaction as slave. o.5: It is mandatory to support at least one of these items

SIST ETS 300 396-8-1 E1:2003 Page 16 ETS 300 396-8-1: January 2000 A.5.6 Type of short data service The supplier of the implementation shall state the support of the implementation for each of the following types of SDSs, in tables A.7 to A.11.

Table A.7: Type of short data service Prerequisite: A.1/2 -- Short Data Services Item Type of short data service Reference Status Support 1 Group address SDS capability 6.3 o.6 2 Individual address SDS capability 6.3 o.6 Pre-defined short data messages (i.e. 6.3 o.7

status messages) 4 User-defined short data messages 6.3 o.7 Over The Air Re-keying (OTAR) (note) 6.3 o.7

6 Enable/disable (note) 6.3 o.7 7 Additional addressing (receive) 6.3.3 c701 8 Additional addressing (send) 6.3.3 c702 NOTE: The detailed PICS proforma for DMO security is defined in a separate PICS proforma covering security aspects.

o.6: It is mandatory to support at least one of these items o.7: It is mandatory to support at least one of these items c701: IF A.6/2 THEN m ELSE n/a -- If receive SDS supported then mandatory c702: IF A.6/1 THEN o ELSE n/a -- If send SDS supported then optional Table A.8: Send short data service on group address Prerequisite: A.6/1 AND A.7/1 -- Group address SDS capability Item SDS on group address Reference Status Support Unacknowledged data service 6.3 m

Table A.9: Send short data service on individual address Prerequisite: A.6/1 AND A.7/2 -- Individual address SDS capability Item SDS on individual address Reference Status Support Unacknowledged data service 6.3 o.8

2 Acknowledged data service 6.3 o.8 Extraction of data if included in ACK 6.3 c901

o.8: It is mandatory to support at least one of these items c901: IF A.9/2 -- If the sending of acknowledged short data supported THEN m -- then mandatory ELSE n/a Table A.10: Receive short data service on group address Prerequisite: A.6/2 AND A.7/1 -- Group address SDS capability Item SDS on group address Reference Status Support Unacknowledged data service 6.3 m

SIST ETS 300 396-8-1 E1:2003 Page 17 ETS 300 396-8-1: January 2000 Table A.11: Receive short data service on individual address Prerequisite: A.6/2 AND A.7/2 -- Individual address SDS capability Item SDS on individual address Reference Status Support Unacknowledged data service 6.3 o.9

2 Acknowledged data service 6.3 o.9

...