SIST EN IEC 61347-2-10:2025
(Main)Controlgear for electric light sources - Safety - Part 2-10: Particular requirements for electronic controlgear for high-frequency operation of cold start tubular discharge lamps (neon tubes) (IEC 61347-2-10:2024)
Controlgear for electric light sources - Safety - Part 2-10: Particular requirements for electronic controlgear for high-frequency operation of cold start tubular discharge lamps (neon tubes) (IEC 61347-2-10:2024)
IEC 61347-2-10:2024 is available as IEC 61347-2-10:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61347-2-10:2024 specifies safety requirements for electronic controlgear for high-frequency operation of tubular cold-cathode discharge lamps used in signs and luminous discharge tube installations and operating with an output voltage exceeding 1 000 V but not exceeding 10 000 V for direct connection to DC or AC supply voltages not exceeding 1 000 V (at 50 Hz or 60 Hz in case of alternating current). This second edition cancels and replaces the first edition published in 2000 and Amendment 1:2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) introduction of dated references as appropriate;
b) clarification of sample item numbers.
Geräte für Lampen - Teil 2-10: Besondere Anforderungen an elektronische Wechselrichter und Konverter für Hochfrequenzbetrieb von röhrenförmigen Kaltstart-Entladungslampen (Neonröhren) (IEC 61347-2-10:2024)
Appareillages de lampes - Partie 2-10: Prescriptions particulières pour onduleurs et convertisseurs électroniques destinés à l'alimentation en haute fréquence des lampes tubulaires à décharge à démarrage à froid (tubes néon) (IEC 61347-2-10:2024)
IEC 61347-2-10:2024 est disponible sous forme de IEC 61347-2-10:2024 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.
L'IEC 61347-2-10:2024 spécifie les exigences de sécurité des appareillages électroniques destinés à l'alimentation en haute fréquence des lampes à décharge tubulaires à cathode froide utilisées dans les enseignes et les installations à tubes à décharge lumineux et qui fonctionnent à une tension de sortie supérieure à 1 000 V, mais ne dépassant pas 10 000 V, pour la connexion directe à des tensions d'alimentation inférieures ou égales à 1 000 V en courant continu ou courant alternatif (à 50 Hz ou 60 Hz en courant alternatif). Cette seconde édition annule et remplace la première édition parue en 2000 et l'Amendement 1:2008. Cette édition constitue une révision technique.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
a) ajout de références datées le cas échéant;
b) clarification des numéros d'entités d'échantillonnage.
Stikalne naprave za sijalke - Varnost - 2-10. del: Posebne zahteve za elektronske stikalne naprave za visokofrekvenčno obratovanje cevastih sijalk s hladnim vžigom (neonske cevi) (IEC 61347-2-10:2024)
Ta del standarda IEC 61347 določa varnostne zahteve za elektronske stikalne naprave za visokofrekvenčno obratovanje cevastih sijalk s hladnim vžigom, ki se uporabljajo v znakih in napravah z razelektritvenimi sijalkami ter delujejo z izhodno napetostjo od 1000 V do 10.000 V, za neposredno priključitev na enosmerno ali izmenično napajalno napetost do največ 1000 V (pri frekvenci 50 Hz oziroma 60 Hz v primeru izmeničnega toka).
OPOMBA 1: V preteklosti so se takšne vrste stikalnih naprav imenovale razsmerniki ali pretvorniki.
OPOMBA 2: Na Japonskem je napetost za uporabo tega dokumenta omejena na 15.000 V.
Ta dokument se uporablja za stikalne naprave tipa A in tipa B, ki so opredeljene, kot sledi:
– Tip A: stikalna naprava, ki deluje v frekvenčnem območju od 20 kHz do 50 kHz, z največjo izhodno napetostjo 5000 V med sponkami, največjim izhodnim tokom 35 mA (RMS) in 50 mA (največja vrednost) ter napajalno napetostjo do največ 250 V.
OPOMBA 3: Pri izhodnem toku enote tipa A se lahko šteje, da ne predstavlja nevarnosti električnega udara zaradi omejitev tokovnega in frekvenčnega območja.
OPOMBA 4: Na Japonskem je sprejemljiva izhodna napetost 15.000 V.
– Tip B: stikalna naprava, ki deluje v frekvenčnem območju od 10 kHz do 100 kHz, z največjo izhodno napetostjo brez obremenitve 10.000 V med sponkami oziroma 5000 V proti zemlji ter največjim izhodnim tokom 200 mA (RMS) in 400 mA (največja vrednost).
OPOMBA 5: Na Japonskem stikalna naprava tipa B z izhodnim tokom, večjim od 50 mA, ni sprejemljiva.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2025
Stikalne naprave za sijalke - Varnost - 2-10. del: Posebne zahteve za elektronske
stikalne naprave za visokofrekvenčno obratovanje cevastih sijalk s hladnim
vžigom (neonske cevi) (IEC 61347-2-10:2024)
Controlgear for electric light sources - Safety - Part 2-10: Particular requirements for
electronic controlgear for high-frequency operation of cold start tubular discharge lamps
(neon tubes) (IEC 61347-2-10:2024)
Geräte für Lampen - Teil 2-10: Besondere Anforderungen an elektronische
Wechselrichter und Konverter für Hochfrequenzbetrieb von röhrenförmigen Kaltstart-
Entladungslampen (Neonröhren) (IEC 61347-2-10:2024)
Appareillages de lampes - Partie 2-10: Prescriptions particulières pour onduleurs et
convertisseurs électroniques destinés à l'alimentation en haute fréquence des lampes
tubulaires à décharge à démarrage à froid (tubes néon) (IEC 61347-2-10:2024)
Ta slovenski standard je istoveten z: EN IEC 61347-2-10:2024
ICS:
29.130.01 Stikalne in krmilne naprave Switchgear and controlgear
na splošno in general
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN IEC 61347-2-10
NORME EUROPÉENNE
EUROPÄISCHE NORM December 2024
ICS 29.140.99 Supersedes EN 61347-2-10:2001; EN 61347-2-
10:2001/A1:2009; EN 61347-2-10:2001/corrigendum Dec.
English Version
Controlgear for electric light sources - Safety - Part 2-10:
Particular requirements - Electronic controlgear for high-
frequency operation of tubular cold-cathode discharge lamps
(neon tubes)
(IEC 61347-2-10:2024)
Appareillages de commande pour les sources de lumière Betriebsgeräte für elektrische Lichtquellen - Sicherheit - Teil
électriques - Sécurité - Partie 2-10: Exigences particulières 2-10: Besondere Anforderungen - elektronische
- Appareillages électroniques destinés à l'alimentation en Wechselrichter und Konverter für Hochfrequenzbetrieb von
haute fréquence des lampes à décharge tubulaires à röhrenförmigen Kaltstart-Entladungslampen (Neonröhren)
cathode froide (tubes néon) (IEC 61347-2-10:2024)
(IEC 61347-2-10:2024)
This European Standard was approved by CENELEC on 2024-10-16. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61347-2-10:2024 E
European foreword
The text of document 34C/1584/CDV, future edition 2 of IEC 61347-2-10, prepared by SC 34C
"Auxiliaries for lamps" of IEC/TC 34 "Lighting" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN IEC 61347-2-10:2024.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2025-12-31
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2027-12-31
document have to be withdrawn
This document supersedes EN 61347-2-10:2001 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 61347-2-10:2024 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 61347-2-10:2000 NOTE Approved as EN 61347-2-10:2001 (not modified)
IEC 61347-2-10:2000/A1:2008 NOTE Approved as EN 61347-2-10:2001/A1:2009 (not modified)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cencenelec.eu.
Publication Year Title EN/HD Year
IEC 60417 - Graphical symbols for use on equipment - -
Luminaires - Part 1: General requirements and
IEC 60598-1 2020 EN IEC 60598-1 2021
tests
+ A11 2022
IEC 61347-1 2015 Lamp controlgear - Part 1: General and safety EN 61347-1 2015
requirements
+ A1 2017 + A1 2021
Graphical symbols - Safety colours and safety
ISO 3864-1 2011 - -
signs - Part 1: Design principles for safety
signs and safety markings
IEC 61347-2-10 ®
Edition 2.0 2024-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Controlgear for electric light sources – Safety –
Part 2-10: Particular requirements – Electronic controlgear for high-frequency
operation of tubular cold-cathode discharge lamps (neon tubes)
Appareillages de commande pour les sources de lumière électriques – Sécurité –
Partie 2-10: Exigences particulières – Appareillages électroniques destinés à
l'alimentation en haute fréquence des lampes à décharge tubulaires à cathode
froide (tubes néon)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.140.99 ISBN 978-2-8322-8839-9
– 2 – IEC 61347-2-10:2024 © IEC 2024
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
4 General requirements . 9
5 General notes on tests . 9
6 Classification . 10
7 Marking . 10
7.1 Marking and information . 10
7.1.1 Mandatory marking . 10
7.1.2 Information to be provided . 10
7.2 Durability and legibility . 11
7.3 Built-in controlgear . 11
8 Terminals . 11
9 Earthing . 11
10 Protection against accidental contact with live parts . 11
11 Moisture resistance and insulation . 12
12 Electric strength . 12
13 Thermal endurance test for windings . 12
14 Normal conditions . 12
15 Abnormal conditions . 13
16 Fault conditions . 13
17 Construction . 14
18 Creepage distances and clearances . 14
19 Protective circuits . 14
19.1 General . 14
19.2 Earth-leakage protection . 15
19.3 Open-circuit protection . 15
20 Screws, current-carrying parts and connections . 16
21 Resistance to heat, fire and tracking . 16
22 Resistance to corrosion . 16
23 No-load rated output voltage and rated output current . 16
24 Applicable annexes of IEC 61347-1 . 16
Annex A (normative) Measurement of current and voltages in the output circuits of
electronic controlgear for neon tubes . 17
A.1 General . 17
A.1.1 Information to be provided by manufacturers . 17
A.1.2 Measurement of output voltage and current . 17
A.1.3 Amplitude modulations. 17
A.1.4 Spikes and high-frequency harmonics. 18
A.1.5 Test conditions . 18
A.2 Instrumentation . 18
A.3 Measurements . 19
IEC 61347-2-10:2024 © IEC 2024 – 3 –
A.3.1 Measurement of no-load output voltage . 19
A.3.2 Measurement of output current . 19
A.3.3 Measurement of earth fault currents . 20
Annex B (informative) Schedule of more onerous requirements . 21
Bibliography . 22
– 4 – IEC 61347-2-10:2024 © IEC 2024
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONTROLGEAR FOR ELECTRIC LIGHT SOURCES – SAFETY –
Part 2-10: Particular requirements –
Electronic controlgear for high-frequency operation of tubular
cold-cathode discharge lamps (neon tubes)
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
may be required to implement this document. However, implementers are cautioned that this may not represent
the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
shall not be held responsible for identifying any or all such patent rights.
IEC 61347-2-10 has been prepared by subcommittee 34C: Auxiliaries for lamps, of IEC
technical committee 34: Lighting. It is an International Standard.
This second edition cancels and replaces the first edition published in 2000 and
Amendment 1:2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) introduction of dated references as appropriate;
b) clarification of sample item numbers.
IEC 61347-2-10:2024 © IEC 2024 – 5 –
The text of this International Standard is based on the following documents:
Draft Report on voting
34C/1584/CDV 34C/1592/RVC
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
This document is intended to be used in conjunction with IEC 61347-1:2015 and
IEC 61347-1:2015/AMD1:2017. Where the requirements of any of the clauses of
IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017 are referred to in this document by the
phrase "IEC 61347-1:2015, Clause n and IEC 61347-1:2015/AMD1:2017, Clause n apply", this
phrase is interpreted as meaning that all the requirements of the clause in question of
IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017 apply, except any which are clearly
inapplicable to the specific type of controlgear covered by this document.
NOTE In this document, the following print type is used:
– compliance statements: in italic type.
A list of all parts in the IEC 61347 series, published under the general title Controlgear for
electric light sources – Safety, can be found on the IEC website.
Future documents in this series will carry the new general title as cited above. Titles of existing
documents in this series will be updated at the time of the next edition.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
• reconfirmed,
• withdrawn, or
• revised.
– 6 – IEC 61347-2-10:2024 © IEC 2024
INTRODUCTION
The technical requirements in this document compared to IEC 61347-2-10:2000 and
IEC 61347-2-10:2000/AMD1:2008 are essentially unchanged. Nevertheless, a new edition of
this document could not be avoided, as without the introduction of dated references to
IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, the fourth edition of IEC 61347-1:—
would have been implicitly applicable due to the undated nature of the references to
IEC 61347-1 in IEC 61347-2-10:2000 and IEC 61347-2-10:2000/AMD1:2008.
This document, in referring to any of the clauses of IEC 61347-1:2015 and
IEC 61347-1:2015/AMD1:2017, specifies the extent to which such a clause is applicable.
Additional requirements are also included, as necessary.
In order to check the safety of controlgear, it is necessary to check their performance. However,
since no standardization of the characteristics of neon tubes exists, reference loads are
specified in this document to ensure reproducible test results.
___________
Fourth edition under preparation. Stage at the time of publication IEC FDIS 61347-1:2024.
IEC 61347-2-10:2024 © IEC 2024 – 7 –
CONTROLGEAR FOR ELECTRIC LIGHT SOURCES – SAFETY –
Part 2-10: Particular requirements –
Electronic controlgear for high-frequency operation of tubular
cold-cathode discharge lamps (neon tubes)
1 Scope
This part of IEC 61347 specifies safety requirements for electronic controlgear for high-
frequency operation of tubular cold-cathode discharge lamps used in signs and luminous
discharge tube installations and operating with an output voltage exceeding 1 000 V but not
exceeding 10 000 V for direct connection to DC or AC supply voltages not exceeding 1 000 V
(at 50 Hz or 60 Hz in case of alternating current).
NOTE 1 Historically, such types of controlgear were referred to as invertors or convertors.
NOTE 2 In Japan, the voltage limit for the application of this document is set to 15 000 V.
This document applies for controlgear of type A and controlgear of type B, which are specified
as follows:
– Type A: controlgear operating within the frequency range 20 kHz to 50 kHz, and having an
output voltage not exceeding 5 000 V peak between terminals, with a maximum output
current limited to 35 mA (RMS) and 50 mA (peak value) and a supply voltage not exceeding
250 V.
NOTE 3 The output current of a type A unit can be considered as not presenting an electric shock hazard due
to the limits on the current and frequency range.
NOTE 4 In Japan, the output voltage of 15 000 V is acceptable.
– Type B: controlgear operating within the frequency range 10 kHz to 100 kHz and having a
no-load output voltage not exceeding 10 000 V between terminals or not exceeding 5 000 V
to earth, with a maximum output current limited to 200 mA (RMS) and 400 mA (peak value).
NOTE 5 In Japan, a type B controlgear providing an output current exceeding 50 mA is not acceptable.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60417, Graphical symbols for use on equipment, available at https://www.graphical-
symbols.info/equipment
IEC 60598-1:2020, Luminaires – Part 1: General requirements and tests
IEC 61347-1:2015, Lamp controlgear – Part 1: General and safety requirements
IEC 61347-1:2015/AMD1:2017
ISO 3864-1:2011, Graphical symbols – Safety colours and safety signs – Part 1: Design
principles for safety signs and safety markings
– 8 – IEC 61347-2-10:2024 © IEC 2024
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61347-1 and the
following apply.
ISO and IEC maintain terminology databases for use in standardization at the following
addresses:
• IEC Electropedia: available at https://www.electropedia.org/
• ISO Online browsing platform: available at https://www.iso.org/obp
3.1
tubular cold-cathode discharge lamp
neon tube
tubular discharge lamp in which the light is produced by the positive column of a glow discharge
Note 1 to entry: These lamps have a low-pressure filling of a rare gas (or a mixture of rare gases) and possibly
mercury vapour. They can have an inside coating of fluorescent materials.
3.2
rated no-load output voltage
U
o
rated maximum voltage between the output terminals or the ends of the integral connecting
leads of the invertor or convertor connected to the rated supply voltage at rated frequency with
no load on the output circuit
Note 1 to entry: For sinusoidal wave forms, the rated no-load output voltage is the RMS value or the peak value
divided by square root of 2. For other waveforms, it is the RMS value or the equivalent value deduced from the peak
value, obtained by mathematical calculation.
Note 2 to entry: For the purposes of this document this definition overrules the one given in IEC 61347-1.
[SOURCE: IEC 61347-1:2015, 3.9, modified – The definition has been adapted for the purposes
of this document and the Notes to entry have been added.]
3.3
invertor
electric energy transducer that converts direct current to alternating current
3.4
convertor
unit for the electronic conversion of AC supply at one frequency to an AC supply at another
frequency
3.5
earth-leakage protective device
device which removes the output power from the controlgear in the event of an earth fault
current flowing between any part of the output high-voltage circuit and earth
3.6
open-circuit protective device
device which removes the output power from the controlgear in the event of non-operation of
the tube load or an interruption in the output high-voltage circuit
Note 1 to entry: An open-circuit protective device may operate by detecting an increase in the output voltage or by
other suitable means.
3.7
upper shut-down limit
output voltage of the controlgear at which an open-circuit protective device operates
IEC 61347-2-10:2024 © IEC 2024 – 9 –
3.8
output high-voltage circuit
that part of the circuit consisting of
a) cables between the output terminals of the controlgear and the discharge tubes,
b) discharge tubes,
c) any series connections between the discharge tubes,
but not including any internal components or wiring of the controlgear
3.9
sample
one or more sampling items intended to provide information on the population or on the material
provided by the manufacturer or responsible vendor
[SOURCE: IEC 60050-151:2001, 151-16-19, modified – "provided by the manufacturer or
responsible vendor" has been added.]
3.10
sample item
one of the individual items in a population of similar items, or a portion of material forming a
cohesive entity and taken from one place and at one time
[SOURCE: IEC 60050-151:2001, 151-16-18]
4 General requirements
IEC 61347-1:2015, Clause 4 applies.
For electronic lamp controlgear with means of protection against overheating, additionally
IEC 61347-1:2015, Annex C applies.
Provisions for the rated maximum temperature of the winding t , are not applicable.
w
5 General notes on tests
IEC 61347-1:2015, Clause 5, applies, together with the following:
– IEC 61347-1:2015, Annex H applies.
– One sample item shall be used for all tests, unless otherwise specified in the corresponding
clause.
To allow for parallel testing and reduced test times, additional sample items may be used
except where the outcome of the test can be affected by preceding tests, for example the
tests of Clause 11 and Clause 12.
Specially prepared sample items may be used where required.