Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-5: Specification of environmental tests; Ground vehicle installations

Specification of environmental tests corresponding to environmental conditions given in Part 1

Inženiring opreme (EE) - Pogoji okolja in preskusi vplivov okolja za telekomunikacijsko opremo – Del 2-5: Specifikacija preskusov vplivov okolja - Inštalacije v kopenskih vozilih

General Information

Status
Published
Publication Date
31-Oct-1999
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Nov-1999
Due Date
01-Nov-1999
Completion Date
01-Nov-1999

Buy Standard

Standard
ETS 300 019-2-5:1999
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST ETS 300 019-2-5:1999
01-november-1999
Inženiring opreme (EE) - Pogoji okolja in preskusi vplivov okolja za
telekomunikacijsko opremo – Del 2-5: Specifikacija preskusov vplivov okolja -
Inštalacije v kopenskih vozilih
Equipment Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 2-5: Specification of environmental tests; Ground
vehicle installations
Ta slovenski standard je istoveten z: ETS 300 019-2-5 Edition 1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST ETS 300 019-2-5:1999 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ETS 300 019-2-5:1999

---------------------- Page: 2 ----------------------

SIST ETS 300 019-2-5:1999
EUROPEAN ETS 300 019-2-5
TELECOMMUNICATION May 1994
STANDARD
Source: ETSI TC-EE Reference: DE/EE-1019-2-5
ICS: 33.080
Environment, specification, equipment
Key words:
Equipment Engineering (EE);
Environmental conditions and environmental tests for
telecommunications equipment
Part 2-5: Specification of environmental tests
Ground vehicle installations
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1994. All rights reserved.
New presentation - see History box

---------------------- Page: 3 ----------------------

SIST ETS 300 019-2-5:1999
Page 2
ETS 300 019-2-5: May 1994
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.

---------------------- Page: 4 ----------------------

SIST ETS 300 019-2-5:1999
Page 3
ETS 300 019-2-5: May 1994
Contents
Foreword .5
1 Scope .7
2 Normative references.7
3 Environmental test specifications.7
3.1 Specification T 5.1: Protected installation.8
3.2 Specification T 5.2: Partly protected installation .13
3.3 Notes to tables 1 to 3.16
Annex A (informative): Bibliography.17
History.18

---------------------- Page: 5 ----------------------

SIST ETS 300 019-2-5:1999
Page 4
ETS 300 019-2-5: May 1994
Blank page

---------------------- Page: 6 ----------------------

SIST ETS 300 019-2-5:1999
Page 5
ETS 300 019-2-5: May 1994
Foreword
This multi-part European Telecommunication Standard (ETS) has been produced by the Equipment
Engineering (EE) Technical Committee of the European Telecommunications Standards Institute (ETSI).
ETS 300 019 is concerned with environmental conditions and environmental tests for telecommunications
equipment and comprises two main parts, each with subdivisions:
- ETS 300 019-1: "Classification of environmental conditions".
Part 1 specifies different standardised environmental classes covering climatic and biological
conditions, chemically and mechanically active substances and mechanical conditions during
storage, transportation and in use.
- ETS 300 019-2: "Specification of environmental tests".
Part 2 specifies the recommended test severities and test methods for the different environmental
classes.
Part 2-0 forms a general overview of Part 2. This part, (Part 2-5), deals with ground vehicle installations.

---------------------- Page: 7 ----------------------

SIST ETS 300 019-2-5:1999
Page 6
ETS 300 019-2-5: May 1994
Blank page

---------------------- Page: 8 ----------------------

SIST ETS 300 019-2-5:1999
Page 7
ETS 300 019-2-5: May 1994
1 Scope
This European Telecommunication Standard (ETS) specifies test methods and severities for the
verification of the required resistibility of equipment according to the relevant environmental class.
The tests in Part 2-5 of this multi-part standard apply to the use of equipment installed permanently or
temporarily in ground vehicles and cover the vehicles and the environmental conditions stated in
ETS 300 019-1-5 [1].
The tests cover installations in vehicles powered by electric motors and combustion engines. Applications
in combustion engine compartments are excluded.
2 Normative references
This ETS incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications
apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest
edition of the publication referred to applies.
[1] ETS 300 019-1-5: "Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment Part 1-5: Classification
of environmental conditions; Ground vehicle installations".
[2] IEC 68-2: "Basic environmental testing procedures. Part 2: Tests".
[3] ETS 300 019-2-0: "Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment Part 2-0: Specification of
environmental tests; Introduction".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are given in Clauses 4 and 5 of ETS 300 019-1-
5 [1].
ETS 300 019-2-0 [3] forms a general overview of Part 2 of this ETS.
The equipment under test is assumed to be in its operational state throughout the test conditions
described in this Part unless otherwise stated. The required performance before, during and after the test
needs to be specified in the product specification. Input and load conditions of the equipment shall be
chosen to obtain full utilisation of the equipment under test. The heat dissipation shall be maximised,
except for the steady state, low temperature test, where it shall be minimised.

---------------------- Page: 9 ----------------------

SIST ETS 300 019-2-5:1999
Page 8
ETS 300 019-2-5: May 1994
3.1 Specification T 5.1: Protected installation
This specification applies to use in weatherprotected heated locations in vehicles which are used in areas with or without well developed road systems depending on
the selected IEC mechanical class. See tables 1, 2 and 2a.
Table 1: Test specification T 5.1: Protected installation - climatic tests
Environmental parameter Environmental Environmental test specification T 5.1: Vehicle,
Class 5.1 protected installation.
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method
severity
low (°C) -25 -25 (11) 16 h IEC 68-2-1 Ab/Ad: Cold (10)
________________________________________________________________________________________________________________________________________________________________________________
(°C) +40 a),e) +40 (1) or +55 16 h IEC 68-2-2 Bb/Bd: Dry heat
___________________________________________________________________________________________________________________________________________________________
high
(°C) +70 b),c) +70 or +85 (2) 16h IEC 68-2-2 Bb/Bd: Dry heat
________________________________________________________________________________________________________________________________________________________________________________
Air rapid (°C) -25/+30 (3)
___________________________________________________________________________________________________________________________________________________________
temperature
(°C) -25/+30 -25/+30 5 cycles IEC 68-2-14 Na: Change of
change (°C/min) 5 not c) t1 = 3 h temperature
____________________________________________________________________________________________________________________________
gradual
(°C) -25/+60 -25/+30 5 cycles IEC 68-2-14 Na: Change of
(°C/min) 10 c) t = 3 h temperature
1
air/water (°C) no not c)
___________________________________________________________________________________________________________________________________________________________
Temperature change air/water (°C) +60/+5 c) (16)
___________________________________________________________________________________________________________________________________________________________
air/snow (°C) +60/-5 c) (16)
slow temperature (%) 95 93 4 d IEC 68-2-56 Cb: Damp heat
change (°C) +40 +40 steady state
___________________________________________________________________________________________________________________________________________________________
(%) 95 90-100 2 cycles IEC 68-2-30 Db: Damp heat,
(°C) -25/+30 not d) +40 cyclic, Variant 2 (19)
rapid temperature _______________________________________________________________________________________
change (%) 95 90-100 2 cycles IEC 68-2-30 Db: Damp heat,
relative (°C) +10/+70 d) +55 cyclic, Variant 2 (19)
___________________________________________________________________________________________________________________________________________________________
Humidity
low (%) 10 (16)
(°C) +30
________________________________________________________________________________________________________________________________________________________________________________
3
absolute rapid temperature (g/m ) 60 (17)
change (°C) +70/+15
Air pressure low (kPa) 70 none
________________________________________________________________________________________________________________________________________________________________________________
speed (m/s) 20 none
(continued)

---------------------- Page: 10 ----------------------

SIST ETS 300 019-2-5:1999
Table 1 (continued): Test specification T 5.1: Protected installation - climatic tests
Environmental parameter Environmental Environmental test specification T 5.1: Vehicle,
Class 5.1 protected installation.
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method
severity
rain intensity no
________________________________________________________________________________________________________________________________________________________________________________
Water other sources velocity (m/s) 0,3 none
________________________________________________________________________________________________________________________________________________________________________________
wetness wet surfaces (4)
2
solar (W/m)700 (22)
________________________________________________________________________________________________________________________________________________________________________________
Radiation
2
heat (W/m)600 (5)
3
SO (mg/m ) 0,3/1,0 (6) none (9)
2
___________________________________________________________________________________________________________________________________________________________
sulphur
3
H S (mg/m ) 0,1/0,5 (6) none (9)
2
________________________________________________________________________________________________________________________________________________________________________________
sea salts salt mist none (9)
___________________________________________________________________________________________________________________________________________________________
chlorine road salts solid salt, none (9)
Chemically salt water
___________________________________________________________________________________________________________________________________________________________
active
3
substances HCl (mg/m ) 0,1/0,5 (6) none (9)
________________________________________________________________________________________________________________________________________________________________________________
3
NO (mg/m ) 0,5/1,0 (6) none (9)
x
___________________________________________________________________________________________________________________________________________________________
nitrogen
3
NH (mg/m ) 1,0/3,0 (6) none (9)
3
________________________________________________________________________________________________________________________________________________________________________________
hydrogen
3
fluoride HF (mg/m ) 0,01/0,03 (6) none (9)
________________________________________________________________________________________________________________________________________________________________________________
3
ozone O (mg/m ) 0,05/0,1 (6) none (9)
3
2
dust sedimentation (mg/(m h)) 3,0 (16)
2
Mechanically (mg/(m h)) 1,0 (7) (16)
________________________________________________________________________________________________________________________________________________________________________________
active
3
substances sand (mg/m ) 0,1 (16)
no (7)
(continued)
Page 9
ETS 300 019-2-5: May 1994

---------------------- Page: 11 ----------------------

SIST ETS 300 019-2-5:1999
Page 10
ETS 300 019-2-5: May 1994
Table 1 (concluded): Test specification T 5.1: Protected installation - climatic tests
Environmental parameter Environmental Environmental test specification T 5.1: Vehicle,
Class 5.1 protected installation
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method
severity
Flora and micro organisms mould, fungus, etc. none (9)
________________________________________________________________________________________________________________________________________________________________________________
Fauna rodents, insects rodents, etc. none (9)
motor no (no (8))
___________________________________________________________________________________________________________________________________________________________
gearbox no (no (8))
___________________________________________________________________________________________________________________________________________________________
oil
hydraulic no (yes (8))
___________________________________________________________________________________________________________________________________________________________
transformer no (yes (8))
________________________________________________________________________________________________________________________________________________________________________________
Contaminating fluid brake no (yes (8))
___________________________________________________________________________________________________________________________________________________________
fluids
cooling no (yes (8))
________________________________________________________________________________________________________________________________________________________________________________
grease no (yes (8))
________________________________________________________________________________________________________________________________________________________________________________
fuel no (no (8))
_______________________________________________________________________________________________________________________________________________________________________________
...

Questions, Comments and Discussion