Foods of plant origin - Multiresidue methods for the determination of pesticide residues by GC or LC-MS/MS - Part 3: Determination and confirmatory tests

This European Standard gives guidance on some recommended techniques for the determination of pesticide residues in foods of plant origin and on confirmatory tests. The identity of any observed pesticide residue is confirmed, particularly in those cases in which it would appear that the maximum residue limit has been exceeded.

Pflanzliche Lebensmittel - Multiverfahren zur Bestimmung von Pestizidrückständen mit GC oder LC-MS/MS - Teil 3: Verfahren zur Bestimmung und Absicherung

Diese Europäische Norm gibt Leitlinien für einige Techniken zur Ermittlung der Pestizidrückstände in pflanzlichen Lebensmitteln und Absicherung der Ergebnisse.
Die Identität jedes gefundenen Pestizid-Rückstandes wird insbesondere dann bestätigt, wenn die Höchstmenge anscheinend überschritten ist.

Aliments d'origine végétale - Méthodes multirésidus de détermination de résidus de pesticides par CPG ou CL-SM/SM - Partie 3: Détermination et essais de confirmation

La présente Norme européenne énonce des lignes directrices relatives aux techniques recommandées pour la détermination des résidus de pesticides dans les aliments d’origine végétale ainsi qu’aux essais de confirmation.
L’identité de tout résidu de pesticide détecté est confirmée, en particulier lorsqu’il semble que la limite maximale de résidu a été dépassée.

Živila rastlinskega izvora - Multirezidualne metode za določevanje ostankov pesticidov s plinsko kromatografijo ali tekočinsko kromatografijo z masno selektivno detekcijo (LC-MS/MS) - 3. del: Določevanje in potrditveni preskusi

Ta evropski standard vsebuje navodila za nekatere priporočene tehnike za določevanje ostankov pesticidov v živilih rastlinskega izvora in za potrditvene preskuse. Identiteta katerih koli opazovanih ostankov pesticidov je potrjena, zlasti kadar se zdi, da je presežena najvišja mejna vrednost ostankov.

General Information

Status
Published
Public Enquiry End Date
24-May-2012
Publication Date
04-Dec-2013
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
25-Nov-2013
Due Date
30-Jan-2014
Completion Date
05-Dec-2013

Relations

Buy Standard

Standard
EN 12393-3:2014
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Pflanzliche Lebensmittel - Multiverfahren zur Bestimmung von Pestizidrückständen mit GC oder LC-MS/MS - Teil 3: Verfahren zur Bestimmung und AbsicherungAliments d'origine végétale - Méthodes multirésidus de détermination de résidus de pesticides par CPG ou CL-SM/SM - Partie 3: Détermination et essais de confirmationFoods of plant origin - Multiresidue methods for the determination of pesticide residues by GC or LC-MS/MS - Part 3: Determination and confirmatory tests67.080.01Sadje, zelenjava in njuni proizvodi na splošnoFruits, vegetables and derived products in general67.050Splošne preskusne in analizne metode za živilske proizvodeGeneral methods of tests and analysis for food productsICS:Ta slovenski standard je istoveten z:EN 12393-3:2013SIST EN 12393-3:2014en,fr,de01-januar-2014SIST EN 12393-3:2014SLOVENSKI
STANDARDSIST EN 12393-3:20091DGRPHãþD



SIST EN 12393-3:2014



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12393-3
November 2013 ICS 67.050 Supersedes EN 12393-3:2008English Version
Foods of plant origin - Multiresidue methods for the determination of pesticide residues by GC or LC-MS/MS - Part 3: Determination and confirmatory tests
Aliments d'origine végétale - Méthodes multirésidus de détermination de résidus de pesticides par CPG ou CL-SM/SM - Partie 3: Détermination et essais de confirmation Pflanzliche Lebensmittel - Multiverfahren zur Bestimmung von Pestizidrückständen mit GC oder LC-MS/MS - Teil 3: Verfahren zur Bestimmung und Absicherung This European Standard was approved by CEN on 21 September 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12393-3:2013: ESIST EN 12393-3:2014



EN 12393-3:2013 (E) 2 Contents Page Foreword .3 Introduction .4 1 Scope .5 2 Normative references .5 3 General .5 4 Determination .5 5 Confirmatory tests .8 Annex A (informative)
Typical GC operating conditions . 10 Annex B (informative)
Typical GC-MS/MS-operating conditions . 12 Annex C (informative)
Typical LC operating conditions . 16 Bibliography . 20
SIST EN 12393-3:2014



EN 12393-3:2013 (E) 3 Foreword This document (EN 12393-3:2013) has been prepared by Technical Committee CEN/TC 275 “Food analysis - Horizontal methods”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2014, and conflicting national standards shall be withdrawn at the latest by May 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12393-3:2008. This document will supersede EN 12393-3:2008 with the following significant technical changes: a) introduction of the LC-MS/MS as a recommended technique for the determination of pesticide residues; b) deletion of method L as no longer in use; c) deletion of old Annex B with considerations concerning MS confirmation; d) addition of a new Annex B with suitable GC-MS/MS operating conditions; e) addition of new Annex C with typical LC-MS/MS operating conditions. EN 12393, Foods of plant origin — Multiresidue methods for the determination of pesticide residues by GC or LC-MS/MS" is divided into three parts:  Part 1 "General considerations" provides general considerations with regard to reagents, apparatus, gas chromatography, etc., applying to each of the analytical selected methods;  Part 2 "Methods for extraction and clean-up" presents methods M, N and P for the extraction and clean-up using techniques such as liquid-liquid partition, adsorption column chromatography or gel permeation column chromatography, etc.;  Part 3 "Determination and confirmatory tests" gives some recommended techniques for the qualitative and the quantitative measurements of residues and the confirmation of the results. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 12393-3:2014



EN 12393-3:2013 (E) 4 Introduction This European Standard comprises a range of multi-residue methods of equal status: no single method can be identified as the prime method because, in this field, methods are continuously developing. The selected methods included in this European Standard have been validated and/or are widely used throughout Europe. Because these methods can be applied to the very wide range of food commodities/pesticide combinations, using different systems for determination, there are occasions when variations in equipment used, extraction, clean-up and chromatographic conditions are appropriate to improve method performance, see Clause 3. SIST EN 12393-3:2014



EN 12393-3:2013 (E) 5 1 Scope This European Standard gives guidance on some recommended techniques for the determination of pesticide residues in foods of plant origin and on confirmatory tests. The identity of any observed pesticide residue is confirmed, particularly in those cases in which it would appear that the maximum residue limit has been exceeded. 2 Normative references Not applicable. 3 General The methods specified in this European Standard permit identification and quantification of pesticide residues by gas chromatography using selective detectors or liquid chromatography with tandem-mass spectrometric detector (LC-MS/MS). All relevant results require confirmation of identity and quantity. The procedures listed for confirmation such as alternative GC columns, alternative GC detectors, high-performance liquid chromatography (HPLC), column fractionation, derivatisation, spectral measurements, etc. are all of value. Results obtained using mass spectrometry (MS) present the most definitive evidence for confirma-tion/identification purpose. As already described in the introduction, in certain occasions it is possible to improve the method performance by variations in equipment used, extraction, clean-up and chromatographic conditions. Such variations shall be always clearly documented and demonstrated to give valid results. 4 Determination 4.1 General
4.1.1 Identification A number of parameters can be employed to determine the identity of an analyte present in the sample extract. This includes:
a) retention time of the analyte in question (RT) or, even better, the retention time ratio against the ISTD (Rt(A)/Rt(ISTD)) obtained from the same run (the simultaneous use of columns of different polarity improves this type of identification);
b) in case of MS or MS/MS detection, the relative abundance of simultaneously recorded signals (in general 3 ions are required in MS applications and 2 SRM transitions in MS/MS);
c) the application of high resolution mass spectrometry;
d) in case of MS with electron impact ionisation the comparison of the full scan mass spectrum of a suspected peak (when indicated after subtraction of background) with spectral libraries; SIST EN 12393-3:2014



EN 12393-3:2013 (E) 6 e) the quantification of equivalent amounts with different specific GC detectors, such as electron capture (ECD), nitrogen-phosphorous (NPD) or flame photometric (FPD) detector. The parameters obtained for the analyte to be identified in the sample extract are compared with those obtained for the pesticides in the calibration solution(s). Should a higher degree of certainty be required for the confirmation of the analyte identity, additional measures may be necessary, such as the use of different chromatographic separation conditions or the evaluation of additional m/z or SRM-transitions. The occurrence of several stable isotopes of certain elements (e.g. Cl, Br, S) may be very helpful to identify substances by MS techniques.
For more information about the required identification criteria, see [1]. 4.1.2 Quantification For quantification, a chromatographic system calibrated with an sufficient number of appropriately distributed calibration points has to be used. The precision of calibration has to fulfil minimum requirements. Make sure that all the measurements are performed within the calibrated range of the system. In exceptional cases only, single-level calibration may be used. It has to be checked that the response of analytes present in complex mixtures does not differ from the response of separate analytes. Mixtures of isomers, degradation products and derivatives of analytes may require special conditions during calibration. For calibration, either standards in solvents or standards prepared in blank matrix (matrix-matched standards) may be used. If matrix effects during GC injection or atmospheric pressure ionisation cannot be excluded, the use of matrix-matched standards or, even better, a quantification by standard addition has to be preferred. To detect instable detector response or such errors, which influence the amount of the analyte in the final extract, one or more internal standards should be added either to extracts or before extraction. To consider specific losses of individual analytes or their matrix effects, stable isotope labelled standards (if available) may be added to the sample before extraction.
All signals automatically identified by software tools may be considered as potential pesticide residues. However, any final quantification of relevant pesticide residues should be based on visual inspection of chromatograms. Before this European Standard can be used to quantify pesticides which are not tested before, a complete initial method validation is required. In all other cases, an on-going performance verification is sufficient to demonstrate the accuracy of the analytical method in a given laboratory.
For more information about the required quantification criteria, see [1] in its current version. 4.2 Gas chromatography (GC) 4.2.1 General The detectors (see EN 12393-1:2013, 3.4) should be properly adjusted, according to the manufacturers' instructions. Variations in detector sensitivity should be checked periodically by verifying the linearity of the calibration curves using standard solutions of pesticides. The measurement may be performed using various instruments, instrument parameters and columns. Some suitable instrument parameters and columns are listed in Annexes A and B.
For suitable experimental conditions of GC-MS measurement, see [2]. For suitable experimental conditions of GC-MS/MS measurement, see [3]. It has been found in practice that equivalent results can be achieved despite the adoption of different GC conditions, and different vendors of instruments. On the other hand, specifying standard GC parameters does not guarantee that the quality of the results generated will be identical. SIST EN 12393-3:2014



EN 12393-3:2013 (E) 7 4.2.2 GC columns Columns should be conditioned for at least 24 h at a temperature near the maximum recommended operating temperature with the type of stationary phase used and should then be tested for their efficiency and selectivity at the required operating temperature using standard mixtures of pesticides. The end of the column should always be disconnected from the detector during conditioning. Pure (oxygen-free) and dry (water-free) nitrogen, hydrogen or helium should be used as carrier gas. The flow rate depends on the size and type of column used. Generally, ensure that gas flow rates are controlled as accurately as possible. Gas purification filters should be installed for all gas supplies and replaced regularly. Finally, make sure that the GC conditions (column length, stationary phase type, injector, detector and column temperatures, gas flow rates, etc.) are such that the separation of the pesticides likely to be present is as complete as possible. Fused silica columns having an internal diameter of 0,20 mm to 0,35 mm and a length of between 10 m and 60 m have proved particularly satisfactory because of their separation efficiency, service life and mechanical properties. Wide bore columns having an internal diameter of 0,5 mm to 0,8 mm may also be useful in some cases. The following stationary phases are frequently used as coatings:  Methyl polysiloxane
equivalent to SE-30, OV-1, OV-101, DB-1, SPB-1, BP-1, HP-1, ULTRA-1, RTx-1, AT-1, CPSil-5, etc.  Methyl 5 % phenyl polysiloxane equivalent to SE-54, OV-23, DB-5, SPB-5, BP-5, HP-5MS, ULTRA 2, RTx-5, CPSil-8, VF-5ms, etc.
 Methyl 50 % phenyl polysiloxane equivalent to OV-17, DB-17, SPB-7, BP-10, HP-17, RTx-17, AT-50, etc.  6 % Cyanopropylphenyl 94 % methyl polysiloxane equivalent to DB-1301, RTx-1301, HP-1301, etc.  Methyl 7 % cyanopropyl 7 % phenyl polysiloxane equivalent to DB-1701, CPSil-19, RTx-1701, AT-1701 OV-1701, CP-SIL-19-CB, BP-10, SPB-7, etc.  50 % Cyanopropyl-phenyl 50 % dimethyl polysiloxane equivalent to SP-2330, CP-Sil 43 CB, OV-225, Rtx-225, BP-225, 007-225, etc.
 Polyethylene glycol equivalent to DB-Wax, Supelcowax 10, Super-ox, CPWax-52, Stabilwax, BP-20, HP-20M, AT-Wax, etc.
4.2.3 Injection techniques Various injection techniques are useful such as split/splitless injection or programmed temperature vaporisation (PTV) injection. The applicability of these techniques depends on the apparatus used and on special requirements. 4.2.4 GC determination The measurement may be performed using various columns, instruments, acquisition parameters and GC detectors. Widely used specific detectors are electron capture (ECD), nitrogen-phosphorous (NPD) and flame photometric (FPD) detectors. Nowadays, GC is more often combined with single stage or tandem mass spectrometers (MS or MS/MS). Some instrument parameters and columns are listed in Annexes A and B.
SIST EN 12393-3:2014



EN 12393-3:2013 (E) 8 Using a mass spectrometer, the determination is often more selective, because either the intensity of a number of previously selected ion is monitored (“SIM mode”) or, after registration of complete mass spectra, an equivalent number of ion chromatograms is reconstructed from the acquired spectra. Mass spectrometers are typically used with electronic impact ionisation (usually 70 eV). For some analytes chemical ionisation (positive or negative) offers better selectivity and sensitivity.
Better selectivity than those obtained with specific detectors or GC-MS is offered by tandem mass spectrometric detection, which allows the selection of intense ions by the first mass filter and the observations of their fragments with the second mass filter.
4.3 Liquid chromatography with tandem-mass spectrometric detection (LC-MS/MS) 4.3.1 General The measurement may be performed using various instruments, instrument parameters and columns.
Some instrument parameters and columns are listed in Annex C.
Beside extensive tuning, the use of tandem mass spectrometry requires for each analyte a substantial set of instrument parameters. For suitable experimental conditions of LC-MS/MS
...