Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures - 65 °C to 175 °C or 200 °C continuous - Part 001: Technical specification

This standard specifies the general characteristics, the conditions for qualification, acceptance and quality assurance, as well as the test programs and groups. These bayonet coupling, scoop-proof, medium and high density connectors are suitable for operating temperatures  65 °C to 175 °C continuous or 200 °C continuous according to class and model.

Luft- und Raumfahrt - Elektrische Rundsteckverbinder, kontaktgeschützt, Bajonettkupplung, Betriebstemperatur - 65 °C bis 175 °C oder 200 °C konstant - Teil 001: Technische Lieferbedingungen

Diese Norm legt die allgemeinen Eigenschaften, die Bedingungen für die Qualifikation, Abnahme und Quali¬tätssicherung sowie die Prüfprogramme und –gruppen fest. Diese kontaktgeschützten Steckverbinder mitt¬lerer und hoher Kontaktdichte mit Bajonettkupplung sind in Abhängigkeit von der Klasse und dem Baumuster geeignet für Betriebstemperaturen von –65 °C bis 175 °C oder 200 °C konstant.

Série aérospatiale - Connecteurs électriques circulaires scoop-proof à accouplement par baïonnettes température d'utilisation - 65 °C à 175 °C ou 200 °C continu - Partie 001 : Spécification technique

Aeronavtika - Konektorji, električni, okrogli, zaščiteni kontakt, z bajonetnim sklapljanjem, stalna delovna temperatura med -65 °C in 175 °C ali 200 °C - 001. del: Tehnična specifikacija

General Information

Status
Published
Publication Date
20-May-2009
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
16-Apr-2009
Due Date
21-Jun-2009
Completion Date
21-May-2009

Buy Standard

Standard
EN 3372-001:2009
English language
61 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Elektrische Rundsteckverbinder, kontaktgeschützt, Bajonettkupplung, Betriebstemperatur - 65 °C bis 175 °C oder 200 °C konstant - Teil 001: Technische LieferbedingungenSérie aérospatiale - Connecteurs électriques circulaires scoop-proof à accouplement par baïonnettes température d'utilisation - 65 °C à 175 °C ou 200 °C continu - Partie 001 : Spécification techniqueAerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures - 65 °C to 175 °C or 200 °C continuous - Part 001: Technical specification49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 3372-001:2007SIST EN 3372-001:2009en,de01-julij-2009SIST EN 3372-001:2009SLOVENSKI
STANDARD



SIST EN 3372-001:2009



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 3372-001
July 2007 ICS 49.060 English Version
Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures - 65 °C to 175 °C or 200 °C continuous -Part 001: Technical specification
Série aérospatiale - Connecteurs électriques circulaires scoop-proof à accouplement par baïonnettes, température d'utilisation - 65 °C à 175 °C ou 200 ° C continu - Partie 001 : Spécification technique
Luft- und Raumfahrt - Elektrische Rundsteckverbinder, kontaktgeschützt, Bajonettkupplung, Betriebstemperatur - 65 °C bis 175 °C oder 200 °C konstant - Teil 001: Technische Lieferbedingungen This European Standard was approved by CEN on 24 June 2006.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 3372-001:2007: ESIST EN 3372-001:2009



EN 3372-001:2007 (E) 2 Contents Page Foreword.3 Introduction.4 1 Scope.4 2 Normative references.4 3 Terms and definitions.5 4 Description.5 4.1 General.5 4.2 Receptacle.6 4.3 Plug.6 4.4 Materials and surface treatment.6 5 Design.7 5.1 Housings.7 5.2 Inserts.7 6 Definition drawings and masses.8 6.1 General.8 6.2 Receptacle mating dimensions.8 6.3 Plug mating dimensions.10 6.4 Receptacle and plug polarisation.13 6.5 Dimensions of the rear accessory interface.14 6.6 Contact arrangements.15 6.7 Contacts dimensions.37 7 Tests.38 7.1 Tests.38 7.2 Gauge to test the holding force of the grounding spring system in the housing.50 7.3 Gauge to test the stability of male contacts in insert.51 8 Quality assurance.52 8.1 General remarks.52 8.2 Qualification.52 8.3 Maintenance of qualification.59 8.4 Routine test during production.59 8.5 Quality control.59 9 Designation and marking.60 9.1 General principle of designation.60 9.2 Marking.60 10 Delivery conditions.61 11 Packaging.61 12 Storage.61
SIST EN 3372-001:2009



EN 3372-001:2007 (E) 3 Foreword This document (EN 3372-001:2007) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has re-ceived the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2008, and conflicting national standards shall be withdrawn at the latest by January 2008. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Repub-lic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 3372-001:2009



EN 3372-001:2007 (E) 4 Introduction This family of connectors is similar to MIL-DTL-38999 series I, with which it is not intermateable or inter-mountable. 1 Scope This standard specifies the general characteristics, the conditions for qualification, acceptance and quality assurance, as well as the test programs and groups. These bayonet coupling, scoop-proof, medium and high density connectors are suitable for operating temperatures − 65 °C to 175 °C continuous or 200 °C continuous according to class and model. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated refer-ences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2267-002, Aerospace series — Cables, electrical, for general purpose — Operating temperatures between − 55 °C and 260 °C — Part 002: General EN 2282, Aerospace series — Characteristics of aircraft electrical supplies EN 2591-100, Aerospace series — Elements of electrical and optical connection — Test methods — Part 100: General (and all associated parts) EN 3155-002, Aerospace series — Electrical contacts used in elements of connection — Part 002: List and utilization of contacts EN 3197, Aerospace series — Installation of aircraft electrical and optical interconnection systems1) EN 3372-002, Aerospace series — Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures − 65 °C to 175 °C or 200 °C continuous — Part 002: Specification of performance and contact arrangements EN 3372-006, Aerospace series — Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures − 65 °C to 175 °C or 200 °C continuous — Part 006: Protective cover for receptacle — Product standard EN 3372-009, Aerospace series — Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures − 65 °C to 175 °C or 200 °C continuous — Part 009: Receptacle, jam nut mounting — Product standard EN 9133, Aerospace series — Quality management systems — Qualification procedure for aerospace standard parts MIL-C-87937, Cleaning compound, aircraft surface, alkaline water base2)
1) Published as an ASD Prestandard on the publication date of this standard 2) Published by: Department of Defense (DOD), the Pentagon, Washington, DC 20301, USA. SIST EN 3372-001:2009



EN 3372-001:2007 (E) 5 MIL-DTL-38999K, Connectors, electrical, circular, miniature, high density, quick disconnect (bayonet, threaded, breech coupling), environment resistant, removable crimp and hermetic solder contacts, general specification for 2) MIL-H-5606E, Hydraulic fluid, petroleum base; aircraft; missile and ordnance2) MIL-HDBK-454A, General guidelines for electronic equipment2) MIL-L-7808J, Lubricating oil, aircraft turbine engine, synthetic base, NATO code number O-2482) MIL-L-7870A, Lubricating oil; general purpose, low temperature2) MIL-L-23699C, Lubricating oil, aircraft turbine engine, synthetic base2) SAE-AMS 1424, Fluid, deicing/anti-icing, aircraft, SAE Type I3) SAE-AS 1241, Fire resistant phosphate ester hydraulic fluid for aircraft3) SAE-AS 39029, Contacts, electrical connector, general specification for3) ISO 263, ISO inch screw threads — General plan and selection for screws, bolts and nuts — Diameter range 0,06 to 6 in ISO 4524-1, Metallic coatings — Test methods for electrodeposited gold and gold alloy coatings — Part 1: Determination of coating thickness ISO 4524-5, Metallic coatings — Test methods for electrodeposited gold and gold alloy coatings — Part 5: Adhesion tests 3 Terms and definitions For the purposes of this standard, the terms and definitions given in EN 2591-100 apply. 4 Description 4.1 General Different variants of materials, housings and contact arrangements are provided according to the classes dependant on the service conditions. These connectors use crimp or solder contacts of sizes 22, 20, 16, 12 and 8. The receptacles and plugs contain either male or female contacts. The contacts fitted in the class Y receptacles are exclusively of the male solder type. For arrangements comprising the letter G, some contacts are grounded to the receptacle housing. The connectors are polarised by means of keyways and keys; polarisation shall be obtained before the male contacts enter the insert of the female contacts and before the coupling ring is engaged. The position of the keying arrangement is given in Table 4.
2) See page 4. 3) Published by: Society of Automotive Engineers, Inc. (SAE), 400 Commonwealth Drive, Warrendale, PA 15096-0001, USA. SIST EN 3372-001:2009



EN 3372-001:2007 (E) 6 The visual check of coupling is obtained by the appearance of the ends of the bayonet pins (blue) through the coupling ring on the plug. 4.2 Receptacle The receptacle fixing may be attached by:  square flange;  jam nut, with sealing by O-ring at the attachment;  round flange for attachment by soldering/brazing/welding. Class Y only. The receptacle contains five keyways into which the keys of the plug engage. The secondary keyways are fixed and are narrower than the main keyway. Polarisation is ensured by different angular positions of the main keyway in relation to the secondary keyways. The position of the insert is fixed relative to the secondary keyways. 4.3 Plug The plug contains five keys that engage in the keyways of the receptacle. The main key is wider than the oth-ers. Polarisation is ensured by different angular positions of the main key in relation to the secondary keys. The position of the insert is fixed relative to the secondary keys. The coupling ring is permanently fitted to the plug and enables the connectors to be coupled and uncoupled. The internal guides of the coupling ring may be treated during manufacture with a suitable lubricant compa-tible with the performance required by this standard. The plug is fitted with a grounding spring device, which ensures electrical continuity between coupled connec-tor housings. 4.4 Materials and surface treatment 4.4.1 General When different metals are in close contact, protection against shall be ensured. The electromotive force of the cell shall not exceed 0,25 V (see EN 3197). 4.4.2 Housings The material of the housings for the connectors and fittings may be either aluminium alloy or passivated stainless steel. Aluminium alloy shall be plated by the class (see EN 3372-002). 4.4.3 Contacts Unless otherwise specified, contacts shall be in ferrous alloy for classes Y and in copper alloy for other classes. They shall be gold-plated on an appropriate undercoat. Selective protection is authorised provided that it is sufficient to ensure that the specified performance is achieved. The use of silver undercoats is prohibited. Measurement of the thickness of the protective plating shall be effected in accordance with ISO 4524-1 (Class Y). For removable contacts see EN 3372-002. SIST EN 3372-001:2009



EN 3372-001:2007 (E) 7 4.4.4 Non-metallic materials The materials used for the inserts, seals and grommets shall have hardness, electrical and mechanical characteristics compatible with the required use. 5 Design 5.1 Housings The connector housings shall be in one unit. The rear of the connector shall contain teeth over its entire pe-riphery that accommodates the rear accessories. The receptacle shall be equipped with a seal for sealing the coupled housings. Receptacles for attachment by nut shall contain an O-ring seal. The nut shall have holes for the passage of locking wire. During coupling, the grounding spring shall be engaged a minimum of 1,02 mm in the receptacle before the contacts engage. Threads shall conform to standard ISO 263, Class 2a. The coupling ring shall be designed so that the male and female contacts engage when it is turned in a clock-wise direction and disengage when it is turned anticlockwise. The coupling ring shall be knurled. Full locking of the connectors shall occur at approximately 120° of rotation. On completion of tightening of the coupling ring, mechanical contact shall exist between the receptacle and plug housings. The appearance of the ends of the bayonet pins, coloured blue, through the plug coupling ring is a visual indication that the con-nectors are correctly mated. 5.2 Inserts The insert carrying the male and female contacts shall be in hard material and have a cross section and radii such that no cracks, flaking or breaks can occur in normal operation. The insert for contacts shall be non-removable; it shall be mechanically held in the housing. Sealing shall be provided between the housing and insert. The front face of the insert shall be such that sealing is ensured when the connectors are coupled. The inter-facial seal of the insert of the male contacts shall be bonded on the hard insert. The grommet shall permit sealing for all cable diameters indicated in EN 3372-002 and shall not be remov-able. The mechanical contact retention system shall be integrated in the hard insert. The design of non-hermetic connectors shall permit individual installation of the contacts without removal of the insert or grommet. Fitting and removal of the contacts shall be from the rear with the tools specified in the contact product standards. SIST EN 3372-001:2009



EN 3372-001:2007 (E) 8 6 Definition drawings and masses 6.1 General The general dimensions and the masses of receptacles, plugs and protective covers are given in the product standards. All dimensions are in mm. 6.2 Receptacle mating dimensions The general dimensions of receptacles are shown in Figures 1, 2 and 3 and in Tables 1 and 2. SIST EN 3372-001:2009



EN 3372-001:2007 (E) 9 Dimensions in millimetres
with socket contact with pin contact a 4 keyways
Keyways with minimum dimension shall be sharp edged. If the smallest dimension is exceeded the corresponding ap-propriate radii are permissible (0,25 mm max). b Point at which a square ended gauge pin with the same diameter as the mating contact first engages with female con-tact tines. Figure 1 — Receptacles SIST EN 3372-001:2009



EN 3372-001:2007 (E) 10 Table 1 — Receptacle mating dimensions Dimensions in millimetres d1 d2 d3 d4 d5 d6 l1 Housing size 0,130,03+− 00,41− min. max. max. 0,150,05+−
8
9,19 14,3
10,31
7,37 12,04 10 12,45 17,27 13,57 10,52 15,02 12 15,42 21,82 17,35 13,49 19,08 14 18,59 24,99 20,53 16,66 22,26 16 21,77 28,14 23,70 19,83 25,43 18 24,43 31,32 26,24 22,10 28,61 20 27,61 34,49 29,42 25,27 31,78 22 30,78 37,67 32,59 28,45 34,96 1,98
24 33,96 40,89 35,77 31,62 38,13 3,18 2,77
Dimensions in millimetresDimensions in millimetres
Figure 2 — Detail of socket entry Figure 3 — Detail of pin barrier
Table 2 — Detail dimensions Dimensions in millimetresD7 D8 Tol d9 Contact size 0,20+
0,050,05+− 22 1,75 0,89 1,65 20 2,31 1,24 2,21 16 2,90 1,8
2,79 12 3,71 2,61 + 0,08 3,61
8 6.90 5,77 + 0,07 6,76
6.3 Plug mating dimensions The mating dimensions of plugs are shown in Figure 4 and Table 3. SIST EN 3372-001:2009



EN 3372-001:2007 (E) 11 Dimensions in millimetres
Key 1 Grounding spring a Plug with grounding spring (shown without coupling ring). b Point at which a square ended gauge pin with the same diameter as the mating contact first engages with female con-tact tines. c Distance from shoulder of connector to locking point. d Keys with maximum dimension shall be sharp-edged. If the maximum dimensions are not achieved appropriate radii are permissible. (0,25 mm max.). Figure 4 — Plugs
SIST EN 3372-001:2009



EN 3372-001:2007 (E) 12
Dimensions in millimetres
View of coupling ring Hole (configuration optional) for visual inspection of coupling ring. Tolerances on distances between holes 0,25 mm Figure 4 (concluded) Table 3 — Plugs dimensions Dimensions in millimetres b1 d10 d11 d12 d13 d14 d15 d16 l2 Housing size 0,40,04+− min. 0,30,03+− min. 0,130,03+− 0,130,25+− 0,130,25+− max. 10+
8 7,44
9,07 8,56 12,22 10,21 14,63 16,0 10 10,56 12,32 11,81 15,29 13,46 17,7 19,1 12 13,54 15,16 14,15 19,33 17,25 22,12 23,5 14 16,71 18,34 17,83 22,48 20,42 25,27 26,7 16 19,88 21,51 21,0 25,65 23,6
28,45 29,8 18 22,42 24,05 23,55 28,85 26,14 31,62 33,1 20 25,6 27,23 26,72 32,00 29,31 34,8 36,5 22 2,29 28,77 30,40 29,9 35,18 32,49 37,97 39,6 2,36 24 3,48 31,95 33,58 33,07 38,35 35,66 41,25 42,9 3,35
SIST EN 3372-001:2009



EN 3372-001:2007 (E) 13 6.4 Receptacle and plug polarisation See Figure 5 and Table 4. Dimensions in millimetres
Receptacle Plug Figure 5 — Polarisation Table 4 — Polarisation index Angular position in degrees Housing size Polarisation index α N
95 A
77 B Not available C Not available
8 D 113 N
95 A
81 B
67 C 123 10 D 109 N
95 A
75 B
63 C 127 12 D 115 N
95 A
74 B
61 C 129 14 D 116
N
95 16 A
77 18 B
65 20 C 125
D 113
N
95 22 A
80 24 B
69
C 121
D 110 SIST EN 3372-001:2009



EN 3372-001:2007 (E) 14 6.5 Dimensions of the rear accessory interface The dimensions of the rear interface of receptacles and plugs with threads for mounting cable outlet accesso-ries are shown in Figure 6 and in Table 5. Dimensions in millimetres
Key 1 Sealing surface a The peak of a tooth shall be ± 2° from the vertical centre line of the connector. Figure 6 — Rear accessory interface Table 5 — Rear accessory interface All classes Flat
d1 d2 d3 l1 mm mm Mm mm Shell size UNEF threadClass 2Aa min. 0,030,13+− max. Number of teeth + 0,5
8 0,4375 -28 10,59
9,70
8,82 12 10 0,5625 -24 13,67 12,67 12,07 16 12 0,6875 -24 16,84 15,85 14,96 20 14 0,8125 -20 19,99 18,72 18,14 24 16 0,9375 -20 23,16 21,89 21,31 28 18 1,0625 -18 26,16 24,89 24,01 32 20 1,1875 -18 29,31 28,04 27,18 36 22 1,3152 -18 32,48 31,22 30,36 40 24 1,4375 -18 35,66 35,66 33,53 44 2,54 a Flattened thread for connector according to ISO 263.
SIST EN 3372-001:2009



EN 3372-001:2007 (E) 15 6.6 Contact arrangements The contact arrangement in the inserts are specified by Figures 7 to 46, which show the front face of male in-serts with the master key in nominal position N. The following tolerances are applicable to the inserts fitted in the housings:  centre of the entry diameter of each female insert (diameter d8, Figure 2):
 centre of the end of each male contact:
Arrangements comprising contacts grounded to the shell (identified by the letter G) are not applicable to plugs. The service ratings applicable to individual inserts are detailed in the following Figure 7 to Figure 46 inclusive. The voltage details can be found in Table 7 — Voltage proof test to EN 2591-207.
SIST EN 3372-001:2009



EN 3372-001:2007 (E) 16 08N35 Rating M 6 contacts, size 22 08N98 Rating I 3 contacts, size 20 10N01 Rating M 1 contact, size 8
Contact X mm Y mm
Contact X mm Y mm
1 + 1,14 + 1,98
A + 1,65 + 0,97
2 + 1,98 – 1,14
B
0 – 2,01
3
0 – 2,29
C – 1,65 + 0,97
4 – 1,98 – 1,14
5 – 1,14 + 1,98
6
0
0
Figure 7 Figure 8 Figure 9
10N35 Rating M 13 contacts, size 22 10N98 Rating I 6 contacts, size 20
Contact X mm Y mm
Contact X mm Y mm
1
0 + 3,71
A
0 + 3,30
2 + 2,16 + 3,00
B + 3,30
0
3 + 3,51 + 1,14
C + 1,65 – 2,87
4 + 3,51 – 1,14
D – 1,65 – 2,87
5 + 2,16 – 3,00
E – 3,30
0
6
0 – 3,71
F
0
0
7 – 2,16 – 3,00
8 – 3,51 – 1,14
9 – 3,51 + 1,14
10 – 2,16 + 3,00
11
0 + 1,42
12 + 1,24 + 0,89
13 – 1,24 – 0,89
Figure 10 Figure 11
SIST EN 3372-001:2009



EN 3372-001:2007 (E) 17 12N04 and 12G04 Rating I 4 contacts, size 16 12N35 Rating M 22 contacts, size 22
Contact X mm Y mm
Contact X mm Y mm Contact X mm Y mm
A
0 + 3,81
1 + 1,14 + 5,00 12 – 4,62 + 2,24
B + 3,71 + 0,89
2 + 3,20 + 4,01 13 – 3,20 + 4,01
C
0 – 2,11
3 + 4,62 + 2,24 14 – 1,14 + 5,00
D – 3,71 + 0,89
4 + 5,16
0 15 + 1,14 + 2,72
5 + 4,62 – 2,24 16 + 2,97 + 0,66
6 + 3,20 – 4,01 17 + 2,36 – 1,91
7 + 1,14 – 5,00 18
0 – 3,05
8 – 1,14 – 5,00 19 – 2,36 – 1,91
9 – 3,20 – 4,01 20 – 2,97 + 0,66
10 – 4,62 – 2,24 21 – 1,14 + 2,72
11 – 5,16
0 22
0 – 0,76
Figure 12 Figure 13 12N98 Rating I 10 contacts, size 20 14N05 and 14G05 Rating II 5 contacts, size 16
Contact X mm Y mm Contact X mm Y mm
Contact X mm Y mm A
0 + 4,95 F – 4,17 – 2,67
A
0 + 2,54 B + 3,18 + 3,81 G – 4,90 + 0,76
B + 4,42 + 0,61 C + 4,90 + 0,76 H – 3,18 + 3,81
C + 2,39 – 3,76 D + 4,17 – 2,67 J + 1,65 – 0,38
D – 2,39 – 3,76 E
0 – 3,43 K – 1,65 – 0,38
E – 4,42 + 0,61
Figure 14 Figure 15
SIST EN 3372-001:2009



EN 3372-001:2007 (E) 18 14N19 Rating I 19 contacts, size 20
Contact X mm Y mm Contact X mm Y mm Contact X mm Y mm A 0
+ 5,72 H – 3,30 – 5,72 R + 3,30 0
B + 3,30 + 5,72 J – 4,95 – 2,87 S + 1,65 – 2,87 C + 4,95 + 2,87 K – 6,60 0
T – 1,65 – 2,87 D + 6,60 0 L – 4,95 + 2,87 U – 3,30 0
E + 4,95 – 2,87 M – 3,30 + 5,72 V 0
0
F + 3,30 – 5,72 N – 1,65 + 2,87
G 0
– 5,72 P + 1,65 + 2,87
Figure 16 14N35 Rating M 37 contacts, size 22
Contact X mm Y mm Contact X mm Y Mm Contact X mm Y mm Contact X mm Y mm
1 + 1,14 + 6,65 11 – 3,30 – 5,89 21 + 4,32 + 1,02 31 + 1,14 + 1,88
2 + 3,12 + 5,51 12 – 5,08 – 4,45 22 + 4,32 – 1,27 32 + 2,29 – 0,10
3 + 5,36 + 4,06 13 – 6,27 – 2,49 23 + 3,12 – 3,23 33 + 1,14 – 2,08
4 + 6,45 + 2,03 14 – 6,76 – 0,25 24 + 1,14 – 4,37 34 – 1,14 – 2,08
5 + 6,76 – 0,25 15 – 6,45 + 2,03 25 – 1,14 – 4,37 35 – 2,29 – 0,10
6 + 6,27 – 2,49 16 – 5,36 + 4,06 26 – 3,12 – 3,23 36 – 1,14 + 1,88
7 + 5,08 – 4,45 17 – 3,12 + 5,51 27 – 4,32 – 1,27 37 0
– 0,10
8 + 3,30 – 5,89 18 – 1,14 + 6,65 28 – 4,32 + 1,02
9 + 1,14 – 6,65 19 + 1,14 + 4,37 29 – 3,12 + 3,02
10 – 1,14 – 6,65 20 + 3,12 + 3,02 30 – 1,14 + 4,37
Figure 17 SIST EN 3372-001:2009



EN 3372-001:2007 (E) 19 14N97 Rating I 8 contacts, size 20 4 contacts, size 16
Contact X mm Y mm Contact X mm Y mm A + 1,65 + 5,94 G – 5,26 – 2,41 B + 4,52 + 4,52 H – 5,94 + 1,65 C + 5,84 – 0,58 J – 4,52 + 4,52 D + 4,52 – 4,52 K – 1,65 + 5,94 E + 1,65 – 5,94 L – 1,19 + 2,06 F – 2,26 – 5,94 M + 1,19 – 2,06 Figure 18 16N06 and 16G06 Rating I 6 contacts, size 12 16N08 and 16G08 Rating II 8 contacts, size 16
Contact X mm Y mm Contact X mm Y mm
ContactX mm Y mm Contact X mm Y mm A + 3,07 + 5,31 D – 6,12 0
A 0
+ 5,99 E – 2,39 – 5,49 B + 6,12 0
E – 3,07 + 5,31
B + 3,25 + 2,18 F – 5,84 – 1,98 C 0
– 6,12 F 0
0
C + 5,84 – 1,98 G – 3,25 + 2,18
D + 2,39 – 5,49 H 0
– 1,32
Figure 19 Figure 20
SIST EN 3372-001:2009



EN 3372-001:2007 (E) 20 16N75 or 16G75 Rating M 2 contacts, size 8
Contact X mm Y mm A 0 + 4,75 B 0 – 4,75
Figure 21 16N26 Rating I 26 contacts, size 22
Contact X mm Y mm Contact X mm Y mm Contact X mm Y mm A
0 + 8,15 K – 4,80 – 6,60 V + 4,53 – 0,91 B + 3,33 + 7,44 L – 7,06 – 4,09 W + 3,02 – 3,84 C + 6,07 + 5,44 M – 8,10 – 0,86 X
0 – 5,16 D + 7,75 + 2,51 N – 7,75 + 2,51 Y – 3,02 – 3,84 E + 8,10 – 0,86 P – 6,07 + 5,44 Z – 4,53 – 0,91 F + 7,06 – 4,09 R – 3,33 + 7,44 a – 4,45 + 2,39 G + 4,80 – 6,60 S – 1,78 + 4,50 b
0 + 1,65 H + 1,70 – 7,98 T + 1,78 + 4,50 c
0 – 1,65 J – 1,70 – 7,98 U + 4,45 + 2,39
Figure 22 SIST EN 3372-001:2009



EN 3372-001:2007 (E) 21 16N35 Rating M 55 contacts, size 22
Contact X mm Y mm Contact X mm Y mm ContactX mm Y mm Contact X mm Y mm
1 – 7,92 + 2,18 15 – 3,96 – 4,67 29 0
– 2,39 43 + 3,96 – 0,10
2 – 7,92 – 0,10 16 – 3,96 – 6,96 30 0
– 4,67 44 + 3,96 – 2,39
3 – 7,92 – 2,39 17 – 2,26 + 8,03 31 0
– 6,96 45 + 3,96 – 4,67
4 – 6,15 + 5,61 18 – 1,98 + 5,61 32 + 2,26 + 8,03 46 + 3,96 – 6,96
5 – 5,94 + 3,33 19 – 1,98 + 3,33 33 + 1,98 + 5,61 47 + 6,15 + 5,61
6 – 5,94 + 1,04 20 – 1,98 + 1,04 34 + 1,98 + 3,33 48 + 5,94 + 3,33
7 – 5,94 – 1,24 21 – 1,98 – 1,24 35 + 1,98 + 1,04 49 + 5,94 + 1,04
8 – 5,94 – 3,53 22 – 1,98 – 3,53 36 + 1,98 – 1,24 50 + 5,94 – 1,24
9 – 5,94 – 5,82 23 – 1,98 – 5,82 37 + 1,98 – 3,53 51 + 5,94 – 3,53 10 – 4,37 + 7,09 24 – 1,98 – 8,10 38 + 1,98 – 5,82 52 + 5,94 – 5,82 11 – 3,96 + 4,47 25 0
+ 8,36 39 + 1,98 – 8,10 53 + 5,94 + 2,18 12 – 3,96 + 2,18 26 0
+ 4,47 40 + 4,37 + 7,09 54 + 7,92 – 0,10 13 – 3,96 – 0,10 27 0
+ 2,18 41 + 3,96 + 4,47 55 + 7,92 – 2,39 14 – 3,96 – 2,39 28 0
– 0,10 42 + 3,96 + 2,18
Figure 23 SIST EN 3372-001:2009



EN 3372-001:2007 (E) 22 16N99 Rating I
2 contacts, size 16 21 contacts, size 20
Contact X mm Y mm Contact X mm Y mm Contact X mm Y mm A 0
+ 8,15 J – 1,70 – 7,98 T + 1,78 + 4,50 B + 3,33 + 7,44 K – 4,80 – 6,60 U + 4,45 + 2,39 C + 6,07 + 5,44 L – 7,06 – 4,09 V + 3,81 – 1,91 D + 7,75 + 2,51 M – 8,10 – 0,86 W 0

...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.