Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 2: Window fastener handles

This document specifies requirements and test methods for durability, strength, security and functionality of window fastener handles.
This document does not apply to the following hardware:
a)   handles - primarily for Tilt and Turn, Tilt-First and Turn-Only hardware, refer to EN 13126-3;
b)   sash fasteners, refer to EN 13126-14;
c)   sliding closing devices, refer to EN 13126-19.
NOTE   The handles covered by this document do not have a spindle and the spur is primarily used to achieve the locked closed position.

Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und Prüfverfahren - Teil 2: Einreiberverschlüsse

Dieses Dokument legt die Anforderungen und Prüfverfahren für die Dauerfunktionstüchtigkeit, Festigkeit, Schutzwirkung und Funktionsweise von Fenstergriffen fest.
Es gilt nicht für die folgenden Baubeschläge:
a)   Griffe überwiegend für Drehkipp , Kippdreh  und Drehbeschläge - hierfür siehe EN 13126-3;
b)   Einreiberverschlüsse für Schiebefenster, siehe EN 13126-14;
c)   Schiebeverschlüsse (SCD), siehe EN 13126-19.
ANMERKUNG   Die von diesem Dokument abgedeckten Griffe haben keinen Dorn, der Sporn wird primär zum Verriegeln in geschlossener Stellung verwendet.

Quincaillerie pour le bâtiment - Ferrures de fenêtres et portes-fenêtres - Exigences et méthodes d'essai - Partie 2 : Poignées à ergot de verrouillage

Le présent document spécifie les exigences et méthodes d'essai relatives à l'endurance, à la résistance, à la sécurité des biens et à la fonctionnalité des poignées à ergot de verrouillage.
Le présent document ne s'applique pas aux ferrures suivantes :
a)   poignées - principalement pour ferrures d'oscillo-battant, de battant-oscillant et d'ouvrant pivotant, se reporter à l'EN 13126-3 ;
b)   verrouillages à came, se reporter à l’EN 13126-14 ;
c)   dispositifs de verrouillage pour ouvrants coulissants (SCD), se reporter à l’EN 13126-19.
NOTE   Les poignées couvertes par le présent document sont dépourvues de carré et l’ergot est principalement utilisé pour atteindre la position fermée et verrouillée.

Stavbno okovje - Okovje za okna in zastekljena vrata - Zahteve in preskusne metode - 2. del: Okenska zapirala

General Information

Status
Published
Public Enquiry End Date
19-Mar-2020
Publication Date
01-Jun-2021
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
14-Apr-2021
Due Date
19-Jun-2021
Completion Date
02-Jun-2021

RELATIONS

Buy Standard

Standard
SIST EN 13126-2:2021
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN 13126-2:2021
01-julij-2021
Nadomešča:
SIST EN 13126-2:2011
Stavbno okovje - Okovje za okna in zastekljena vrata - Zahteve in preskusne
metode - 2. del: Okenska zapirala

Building hardware - Hardware for windows and door height windows - Requirements and

test methods - Part 2: Window fastener handles
Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und
Prüfverfahren - Teil 2: Einreiberverschlüsse

Quincaillerie pour le bâtiment - Ferrures de fenêtres et portes-fenêtres - Exigences et

méthodes d'essai - Partie 2 : Poignées à ergot de verrouillage
Ta slovenski standard je istoveten z: EN 13126-2:2021
ICS:
91.190 Stavbna oprema Building accessories
SIST EN 13126-2:2021 en,fr,de

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 13126-2:2021
---------------------- Page: 2 ----------------------
SIST EN 13126-2:2021
EN 13126-2
EUROPEAN STANDARD
NORME EUROPÉENNE
March 2021
EUROPÄISCHE NORM
ICS 91.190 Supersedes EN 13126-2:2011
English Version
Building hardware - Hardware for windows and door
height windows - Requirements and test methods - Part 2:
Window fastener handles

Quincaillerie pour le bâtiment - Ferrures de fenêtres et Baubeschläge - Beschläge für Fenster und Fenstertüren

portes-fenêtres - Exigences et méthodes d'essai - Partie - Anforderungen und Prüfverfahren - Teil 2:

2 : Poignées à ergot de verrouillage Einreiberverschlüsse
This European Standard was approved by CEN on 8 February 2021.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this

European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references

concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN

member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by

translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management

Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,

Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,

Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and

United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels

© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13126-2:2021 E

worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 13126-2:2021
EN 13126-2:2021 (E)
Contents Page

European foreword ....................................................................................................................................................... 3

1 Scope .................................................................................................................................................................... 6

2 Normative references .................................................................................................................................... 6

3 Terms and definitions ................................................................................................................................... 6

4 Classification ..................................................................................................................................................... 8

4.1 General ................................................................................................................................................................ 8

4.2 Durability (1 – first box) ............................................................................................................................... 8

4.3 Mass (2 – second box) .................................................................................................................................... 8

4.4 Corrosion resistance (3 – third box) ........................................................................................................ 8

4.5 Test sizes (4 – fourth box) ............................................................................................................................ 8

4.6 Security against burglar attack (5 – fifth box) ...................................................................................... 8

4.7 Key related security (6 – sixth box) .......................................................................................................... 8

4.8 Example of classification for window fastener handles .................................................................... 9

5 Requirements ................................................................................................................................................... 9

5.1 Dangerous substances ................................................................................................................................... 9

5.2 Operating torque ............................................................................................................................................. 9

5.3 Torsion strength .............................................................................................................................................. 9

5.4 Tensile strength – eccentric ..................................................................................................................... 10

5.5 Simulated pressure ..................................................................................................................................... 10

5.6 Pull-in ............................................................................................................................................................... 10

5.7 Durability ........................................................................................................................................................ 10

5.8 Security ............................................................................................................................................................ 10

5.9 Corrosion resistance ................................................................................................................................... 12

6 Test equipment and preparation for the test .................................................................................... 12

7 Test procedure .............................................................................................................................................. 12

7.1 Samples ............................................................................................................................................................ 12

7.2 Operating torque test procedure ........................................................................................................... 13

7.3 Torsion strength test procedure ............................................................................................................ 13

7.4 Tensile strength test procedure – eccentric ....................................................................................... 13

7.5 Simulated pressure test procedure ....................................................................................................... 13

7.6 Pull-in test ....................................................................................................................................................... 14

7.7 Durability test procedure .......................................................................................................................... 14

7.8 Security ............................................................................................................................................................ 14

7.9 Corrosion resistance ................................................................................................................................... 15

8 Marking ............................................................................................................................................................ 16

Annex A (informative) Flow chart of test procedures .................................................................................. 17

Annex B (informative) Figures ............................................................................................................................. 19

Bibliography ................................................................................................................................................................. 22

---------------------- Page: 4 ----------------------
SIST EN 13126-2:2021
EN 13126-2:2021 (E)
European foreword

This document (EN 13126-2:2021) has been prepared by Technical Committee CEN/TC 33 “Doors,

windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR.

This European Standard shall be given the status of a national standard, either by publication of an

identical text or by endorsement, at the latest by September 2021, and conflicting national standards

shall be withdrawn at the latest by September 2021.

Attention is drawn to the possibility that some of the elements of this document may be the subject of

patent rights. CEN shall not be held responsible for identifying any or all such patent rights.

This document supersedes EN 13126-2:2011.
With regard to EN 13126-2:2011, the following significant changes were made:

— EN 13126-2 now is independent from EN 13126-1; all necessary information are included without

the need of any further information from EN 13126-1;
— several editorial changings in the wording for a better understanding;

— terms under 3.4 'locking mechanism”, 3.10 'sample', 3.11 'specimen' and 3.12 'test-rig' added; term

under 3.6 'key operated locking mechanism' modified for better understanding;

— under 4.1 classification system changed completely; former digits 1 (Category of use), 4 (Fire

resistance), 5 (Safety in use) and 8 (Application) deleted; former digit 2 changed into box 1

(Durability), former digit 3 changed into box 2 (Mass), former digit 6 changed into box 3 (Corrosion

resistance), former digit 9 changed into box 4 (Test sizes); former digit 7 changed into box 5

(Security against burglar attack), new box 6 (Key related security);

— under 4.2 new grades for the number of cycles defined; H1 (5 000), H2 (10 000) and H3 (20 000);

see also 5.7;
— under 4.8 new example added for the new classification;

— under 5.7 new grades for the number of cycles defined; H1 (5 000), H2 (10 000) and H3 (20 000) in

accordance with 4.2 established;

— under 5.8.1 former Table 2 deleted; all values are listed unchanged in the corresponding clauses

and subclauses;

— under 5.8.2 the number of cycles adapted to the newly defined grades for the durability;

— under 5.8.4 and 5.8.5 grade 3 added with 200 Nm;

— under 5.8.6 subclause for locking variations regarding key related security added;

— under 5.9 subclause for corrosion resistance added;
— under 6 headline modified with “…and preparation for the test”;
— under 7.8 sublause for security added with new structure;
---------------------- Page: 5 ----------------------
SIST EN 13126-2:2021
EN 13126-2:2021 (E)

— under Clause 8 new clause added regarding marking with information from the current version of

EN 13126-1.

This document is one of a series of European standards for building hardware products for windows

and door height windows. This document is independent of EN 13126-1.
EN 13126 consists of the following parts:

— EN 13126-1, Building hardware — Hardware for windows and door height windows — Requirements

and test methods — Part 1: Requirements common to all types of hardware;

— EN 13126-2, Building hardware — Hardware for windows and door height windows — Requirements

and test methods — Part 2: Window fastener handles;

— EN 13126-3, Building hardware — Hardware for windows and door-height windows — Requirements

and test methods — Part 3: Handles, primarily for Tilt and Turn, Tilt-First and Turn-Only hardware;

— EN 13126-4, Building hardware — Requirements and test methods for windows and door height

windows — Part 4: Espagnolettes;

— EN 13126-5, Building hardware — Hardware for windows and door height windows — Requirements

and test methods — Part 5: Devices that restrict the opening of windows and door height windows;

— EN 13126-6, Building hardware — Hardware for windows and door height windows — Requirements

and test methods — Part 6: Variable geometry stay hinges (with or without a friction stay);

— EN 13126-7, Building hardware — Requirements and test methods for windows and door height

windows — Part 7: Finger catches;

— EN 13126-8, Building hardware — Hardware for windows and door height windows — Part 8:

Requirements and test methods for tilt and turn, Tilt-First and Turn-Only hardware;

— EN 13126-9, Building hardware — Requirements and test methods for windows and door height

windows — Part 9: Hardware for horizontal and vertical pivot windows;

— EN 13126-10, Building hardware — Requirements and test methods for windows and door height

windows — Part 10: Arm-balancing systems;

— EN 13126-11, Building hardware — Requirements and test methods for windows and door height

windows — Part 11: Top hung projecting reversible hardware;

— EN 13126-12, Building hardware — Requirements and test methods for windows and door height

windows — Part 12: Side hung projecting reversible hardware;

— EN 13126-13, Building hardware — Hardware for windows and balcony door — Requirements and

test methods — Part 13: Sash balances;

— EN 13126-14, Building hardware — Hardware for windows and balcony door — Requirements and

test methods — Part 14: Sash fasteners;

— EN 13126-15, Building hardware — Hardware for windows and balcony door — Requirements and

test methods — Part 15: Rollers for sliding and hardware for sliding folding windows;

---------------------- Page: 6 ----------------------
SIST EN 13126-2:2021
EN 13126-2:2021 (E)

— EN 13126-16, Building hardware — Hardware for windows and balcony door — Requirements and

test methods — Part 16: Hardware for Lift and Slide windows;

— EN 13126-17, Building hardware — Hardware for windows and balcony door — Requirements and

test methods — Part 17: Hardware for Tilt and Slide windows;

— EN 13126-19, Building hardware — Requirements and test methods for windows and door height

windows — Part 19: Sliding Closing Devices

According to the CEN-CENELEC Internal Regulations, the national standards organisations of the

following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,

Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,

Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of

North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the

United Kingdom.
---------------------- Page: 7 ----------------------
SIST EN 13126-2:2021
EN 13126-2:2021 (E)
1 Scope

This document specifies requirements and test methods for durability, strength, security and

functionality of window fastener handles.
This document does not apply to the following hardware:

a) handles - primarily for Tilt and Turn, Tilt-First and Turn-Only hardware, refer to EN 13126-3;

b) sash fasteners, refer to EN 13126-14;
c) sliding closing devices, refer to EN 13126-19.

NOTE The handles covered by this document do not have a spindle and the spur is primarily used to achieve

the locked closed position.
2 Normative references

The following documents are referred to in the text in such a way that some of all of their contents

constitute requirements of this document. For dated references, only the edition cited applies. For

undated references, the latest edition of the referenced document (including any amendments) applies.

EN 1670, Building hardware — Corrosion resistance — Requirements and test methods

3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.

ISO and IEC maintain terminological databases for use in standardization at the following addresses:

— IEC Electropedia: available at http://www.electropedia.org/
— ISO Online browsing platform: available at https://www.iso.org/obp
3.1
window fastener handle

operating device to hold the window in a closed position, with or without a locking mechanism (key-

operated or a non key operated)
Note 1 to entry: Also known as Cockspur handles.
3.2
spur

part projecting from the handle that interacts with the compression wedge / keeper to close the

window to give the desired pull-in
3.3
pull-in

distance the sash is moved towards the frame during operation of a window fastener handle from the

initial contact of the handle spur to the fully closed position
3.4
locking mechanism

assembly of components to ensure the locked position of the handle and to prevent the movement of

the handle from the locked position
---------------------- Page: 8 ----------------------
SIST EN 13126-2:2021
EN 13126-2:2021 (E)
3.5
non-key operated locking mechanism
locking mechanism not operated by a key
Note 1 to entry: For example ‘push-to-open’, button, thumb turn.
3.6
key operated locking mechanism
locking mechanism operated by appropriate means (e.g. a key)
3.7
compression wedge / keeper

component applied to the window frame in a position, that allow interaction with the handle spur to

hold the window in a closed position
3.8
weather seal

compressible gasket between the sash and the frame that prevents air and water ingress

3.9
closing conditions
3.9.1
closed position

situation in which the hardware is not engaged and the active sash is resting up against the frame or

weather seal
3.9.2
locked closed position

situation in which the active sash rests up against the frame and the hardware is engaged

3.9.3
secured position

situation in which the active sash rests up against the frame and the hardware is engaged and the

locking mechanism of the handle is activated, e.g. by a key
3.10
sample
hardware component which shall be tested
3.11
specimen
window to accommodate hardware components (samples) for testing
3.12
test-rig
testing device onto which the specimen is mounted
---------------------- Page: 9 ----------------------
SIST EN 13126-2:2021
EN 13126-2:2021 (E)
4 Classification
4.1 General

Window fastener handles shall be classified in accordance with the six box classification system (see

Table 1).
Table 1 — Classification system of hardware
box 1 2 3 4 5 6
Security
Key
Corrosion against
characteristic Durability Mass Test sizes related
resistance burglar
security
attack
4.2 Durability (1 – first box)

The first box shall display the grade applied to the durability test in accordance with 5.7:

— grade H1: 5 000;
— grade H2: 10 000;
— grade H3: 20 000.
4.3 Mass (2 – second box)
No requirements, the second box shall display the digit 0.
4.4 Corrosion resistance (3 – third box)

The third box shall display the grade regarding corrosion resistance in accordance with 5.9.

4.5 Test sizes (4 – fourth box)
No requirements, the fourth box shall display the digit 0.
4.6 Security against burglar attack (5 – fifth box)
The fifth box shall display the grade of the security against burglar attack:
— grade 0: without security against burglar attack;
— grade 1: 35 Nm resistance against twisting-off and forcing-off;
— grade 2: 100 Nm resistance against twisting-off and forcing-off;
— grade 3: 200 Nm resitance against twisting-off and forcing-off.
4.7 Key related security (6 – sixth box)
— grade 0: no locking mechanism;
— grade 1: non-key operated locking mechanism (e.g. ‘PTO’: Push-to-open);
— grade 2: key-operated locking mechanism with ≥ 30 and ≤ 99 locking variations;
— grade 3: key-operated locking mechanism with ≥ 100 locking variations.
---------------------- Page: 10 ----------------------
SIST EN 13126-2:2021
EN 13126-2:2021 (E)
4.8 Example of classification for window fastener handles
a) Alternative 1: Table with boxes (see Table 2).
Table 2 — Example of cl
...

Questions, Comments and Discussion