Fibre optic interconnecting devices and passive components - Reliability - Part 9-1: Qualification of passive optical components (IEC 62005-9-1:2015)

This part of IEC 62005 establishes a general reliability qualification program that applies to all
passive fibre optic components except connectors and connector assemblies, the passing of
which, suggests a minimum level of reliability assurance and allows that specific device to be
called qualified to this standard.
The objectives of this International Standard are as follows:
– to specify the requirements for a general reliability qualification standard (RQS) for
passive optical components;
– to give direction to the supplier and to the end user on the production and purchase of
passive optical components to meet and verify reliability qualification standards for certain
specified service environments;
– to give the minimum list of reliability qualification stress tests and conditions;
– to establish guidance for the selection of appropriate measurements and pass/fail criteria;
– to give relevant references; and
– to establish the minimum reporting requirements.
This standard defines a series of stress tests, their severity, sequences, quantities of devices
under the test (DUT), acceptance criteria, and reporting requirements. It also gives guidelines
to selecting appropriate measurements and pass/fail criteria.

Lichtwellenleiter - Verbindungselemente und passive Bauteile - Zuverlässigkeit - Teil 9-1: Beurteilung der passiven optischen Bauteil (IEC 62005-9-1:2015)

Dispositifs d'interconnexion et composants passifs à fibres optiques - Fiabilité - Partie 9-1: Qualification des composants optiques passifs (IEC 62005-9-1:2015)

L'IEC 62005-9-1:2015 détermine un programme de qualification général relatif à la fiabilité s'appliquant à tous les composants passifs à fibres optiques à l'exception des connecteurs et des assemblages de connecteurs, dont l'acceptation suggère un niveau minimum d'assurance de fiabilité et permet de déclarer ce dispositif spécifique qualifié selon la présente norme. Les objectifs de la présente Norme internationale sont les suivants:
- la spécification des exigences d'une norme générale de qualification relative à la fiabilité (RQS) pour les composants optiques passifs;
- la communication de directives pour le fournisseur et pour l'utilisateur final, relatives à la fabrication et à l'achat de composants optiques passifs satisfaisant aux normes de qualification relatives à la fiabilité et les vérifiant, pour certains environnements de service spécifiés;
- la fourniture de la liste minimale d'essais et de conditions de contraintes de qualification relatives à la fiabilité;
- l'établissement de lignes directrices pour la sélection des mesures appropriées et des critères d'acceptation/rejet;
- la fourniture de références appropriées;
- et l'établissement des exigences minimales concernant les rapports. Cette norme définit une série d'essais de contrainte, leur sévérité, les séquences, le nombre de dispositifs soumis à essai (DUT), les critères d'acceptation et les exigences concernant les rapports. Elle fournit également des lignes directrices pour sélectionner les mesures appropriées ainsi que les critères d'acceptation/rejet.
Mots clés: norme de qualification relative à la fiabilité (RQS) pour les composants optiques passifs

Optični spojni elementi in pasivne komponente - Zanesljivost - 9-1. del: Kvalificiranje pasivnih optičnih komponent (IEC 62005-9-1:2015)

Ta del standarda IEC 62005 vzpostavlja program kvalificiranja za splošno zanesljivost, ki velja za vse pasivne optične komponente, razen konektorjev in sestavov konektorjev, katerih prehod predlaga najmanjšo raven zagotovitve zanesljivosti ter omogoča kvalificiranje zadevne naprave s tem standardom.
Cilji tega mednarodnega standarda so naslednji:
– določitev zahtev splošnega standarda za kvalificiranje zanesljivosti za pasivne optične komponente;
– usmeritev dobavitelja in končnega uporabnika glede proizvodnje in nabave pasivnih optičnih komponent, in sicer za zagotovitev izpolnjevanja (in preverjanje) standardov za kvalificiranje zanesljivosti za določena navedena storitvena okolja;
– zagotovitev minimalnega seznama obremenitvenih preskusov in pogojev za kvalificiranje zanesljivosti;
– vzpostavitev smernic za izbiro primernih meritev in pogojev za uspešno/neuspešno kvalificiranje;
– zagotovitev zadevnih referenc; ter
– vzpostavitev minimalnih zahtev glede poročanja.
Ta standard določa serijo obremenitvenih preskusov, njihovo zahtevnost in zaporedje, količino naprav v preskusu (DUT), pogoje za uspešno kvalificiranje ter zahteve glede poročanja. Poleg tega podaja smernice za izbiro primernih meritev in pogojev za uspešno/neuspešno kvalificiranje.

General Information

Status
Published
Publication Date
10-Jan-2016
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
14-Oct-2015
Due Date
19-Dec-2015
Completion Date
11-Jan-2016

Buy Standard

Standard
EN 62005-9-1:2016
English language
46 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
EN 62005-9-1:2016 - brez pretiska, ref. oznaka se pri IEC standardu prestavi na sredino strani
English language
46 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 62005-9-1:2016
01-februar-2016
Optični spojni elementi in pasivne komponente - Zanesljivost - 9-1. del:
Kvalificiranje pasivnih optičnih komponent (IEC 62005-9-1:2015)
Fibre optic interconnecting devices and passive components - Reliability - Part 9-1:
Qualification of passive optical components (IEC 62005-9-1:2015)
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Zuverlässigkeit - Teil 9-1:
Beurteilung der passiven optischen Bauteil (IEC 62005-9-1:2015)
Dispositifs d'interconnexion et composants passifs à fibres optiques - Fiabilité - Partie 9-
1: Qualification des composants optiques passifs (IEC 62005-9-1:2015)
Ta slovenski standard je istoveten z: EN 62005-9-1:2015
ICS:
33.180.20 Povezovalne naprave za Fibre optic interconnecting
optična vlakna devices
SIST EN 62005-9-1:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 62005-9-1:2016

---------------------- Page: 2 ----------------------
SIST EN 62005-9-1:2016


EUROPEAN STANDARD EN 62005-9-1

NORME EUROPÉENNE

EUROPÄISCHE NORM
October 2015
ICS 33.180.20

English Version
Fibre optic interconnecting devices and passive components -
Reliability - Part 9-1: Qualification of passive optical components
(IEC 62005-9-1:2015)
Dispositifs d'interconnexion et composants passifs à fibres Lichtwellenleiter - Verbindungselemente und passive
optiques - Fiabilité - Partie 9-1: Qualification des Bauteile - Zuverlässigkeit - Teil 9-1: Beurteilung der
composants optiques passifs passiven optischen Bauteile
(IEC 62005-9-1:2015) (IEC 62005-9-1:2015)
This European Standard was approved by CENELEC on 2015-07-30. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 62005-9-1:2015 E

---------------------- Page: 3 ----------------------
SIST EN 62005-9-1:2016
EN 62005-9-1:2015
European foreword
The text of document 86B/3896/FDIS, future edition 1 of IEC 62005-9-1, prepared by SC 86B "Fibre
optic interconnecting devices and passive components" of IEC/TC 86 "Fibre optics" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN 62005-9-1:2015.
The following dates are fixed:
(dop) 2016-04-30
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2018-07-30
• latest date by which the national standards conflicting with
the document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 62005-9-1:2015 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 61300-2-5 NOTE Harmonized as EN 61300-2-5.
IEC 61300-2-6 NOTE Harmonized as EN 61300-2-6.
IEC 61300-2-7 NOTE Harmonized as EN 61300-2-7.
IEC 61300-2-14 NOTE Harmonized as EN 61300-2-14.
IEC 61300-2-15 NOTE Harmonized as EN 61300-2-15.
IEC 61300-2-35 NOTE Harmonized as EN 61300-2-35.
2

---------------------- Page: 4 ----------------------
SIST EN 62005-9-1:2016
EN 62005-9-1:2015
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.

Publication Year Title EN/HD Year
IEC 60749-26 -  Semiconductor devices - Mechanical and EN 60749-26 -
climatic test methods -
Part 26: Electrostatic discharge (ESD)
sensitivity testing - Human body model
(HBM)
IEC 61300 series Fibre optic interconnecting devices and EN 61300 series
passive components - Basic test and
measurement procedures
IEC 61300-2-1 -  Fibre optic interconnecting devices and EN 61300-2-1 -
passive components - Basic test and
measurement procedures -
Part 2-1: Tests - Vibration (sinusoidal)
IEC 61300-2-4 -  Fibre optic interconnecting devices and EN 61300-2-4 -
passive components - Basic test and
measurement procedures -
Part 2-4: Tests - Fibre/cable retention
IEC 61300-2-9 -  Fibre optic interconnecting devices and EN 61300-2-9 -
passive components - Basic test and
measurement procedures -
Part 2-9: Tests - Shock
IEC 61300-2-17 -  Fibre optic interconnecting devices and EN 61300-2-17 -
passive components - Basic test and
measurement procedures -
Part 2-17: Tests - Cold
IEC 61300-2-18 -  Fibre optic interconnecting devices and EN 61300-2-18 -
passive components - Basic test and
measurement procedures -
Part 2-18: Tests - Dry heat - High
temperature endurance
IEC 61300-2-19 -  Fibre optic interconnecting devices and EN 61300-2-19 -
passive components - Basic test and
measurement procedures -
Part 2-19: Tests - Damp heat (steady state)
3

---------------------- Page: 5 ----------------------
SIST EN 62005-9-1:2016
EN 62005-9-1:2015
Publication Year Title EN/HD Year
IEC 61300-2-22 -  Fibre optic interconnecting devices and EN 61300-2-22 -
passive components - Basic test and
measurement procedures -
Part 2-22: Tests - Change of temperature
IEC 61300-2-42 -  Fibre optic interconnecting devices and EN 61300-2-42 -
passive components - Basic test and
measurement procedures -
Part 2-42: Tests - Static side load for strain
relief
IEC 61300-2-44 -  Fibre optic interconnecting devices and EN 61300-2-44 -
passive components - Basic test and
measurement procedures -
Part 2-44: Tests - Flexing of the strain relief
of fibre optic devices
IEC 61300-2-47 -  Fibre optic interconnecting devices and EN 61300-2-47 -
passive components - Basic test and
measurement procedures -
Part 2-47: Tests - Thermal shocks
IEC 61753 series Fibre optic interconnecting devices and EN 61753 series
passive components - Performance
standard
IEC 61753-1 -  Fibre optic interconnecting devices and EN 61753-1 -
passive components performance
standard -
Part 1: General and guidance for
performance standards
IEC 62005 series Fibre optic interconnecting devices and EN 62005 series
passive components - Reliability
IEC 62005-1 -  Reliability of fibre optic interconnecting EN 62005-1 -
devices and passive components -
Part 1: Introductory guide and definitions

4

---------------------- Page: 6 ----------------------
SIST EN 62005-9-1:2016



IEC 62005-9-1

®


Edition 1.0 2015-06




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE











Fibre optic interconnecting devices and passive components – Reliability –

Part 9-1: Qualification of passive optical components




Dispositifs d'interconnexion et composants passifs à fibres optiques –

Fiabilité –

Partie 9-1: Qualification des composants optiques passifs















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 33.180.20 ISBN 978-2-8322-2749-7



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------
SIST EN 62005-9-1:2016
– 2 – IEC 62005-9-1:2015  IEC 2015
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references. 7
3 Terms, definitions and abbreviations . 8
3.1 Terms and definitions . 8
3.2 Abbreviations . 9
4 General requirements . 9
4.1 DUT . 9
4.2 Product family . 9
4.3 Service environments . 9
5 Tests . 10
5.1 General . 10
5.2 Quantity of the DUTs . 10
5.3 Sequence . 10
5.4 Acceptance criteria . 10
5.5 Test methods . 10
5.6 Severity . 11
6 Measurements . 11
6.1 General . 11
6.2 Measurements . 11
6.3 Pass/fail criteria . 11
6.4 Measurement methods . 11
6.5 Required leak rate and residual gas analysis measurements . 11
7 Report . 11
Annex A (normative)  Required reliability qualification tests for passive optical
components used in category C, controlled environments . 13
Annex B (normative) Required reliability qualification tests for passive optical
components used in category U, uncontrolled environments . 15
Annex C (normative) Required reliability qualification tests for passive optical
components used in category O, uncontrolled environments (sequential) . 16
Annex D (informative) Informative and optional reliability qualification tests for passive
optical components used in category C, category U and category O environments . 18
D.1 Informative and optional reliability qualification tests for passive optical
components used in category C, controlled environments . 18
D.2 Optional reliability qualification tests for passive optical components used in
category U, uncontrolled environments . 20
D.3 Informative reliability qualification tests for passive optical components used
in category O, uncontrolled environments (sequential) . 20
Annex E (informative) Failure mode and known failure mechanisms for passive optical
components . 22
Bibliography . 42

Table 1 – Service environments . 10
Table A.1 – Required reliability qualification tests for passive optical components used
in category C, controlled environments (1 of 2) . 13

---------------------- Page: 8 ----------------------
SIST EN 62005-9-1:2016
IEC 62005-9-1:2015  IEC 2015 – 3 –
Table B.1 – Required reliability qualification tests for passive optical components used
in category U, uncontrolled environments . 15
Table C.1 – Required reliability qualification tests for passive optical components used
in category O, uncontrolled environments (sequential) (1 of 2) . 16
Table D.1 – Informative and optional reliability qualification tests for passive optical
components used in category C, controlled environments (1 of 2) . 18
Table D.2 – Optional reliability qualification tests for passive optical components used
in category U, uncontrolled environments . 20
Table D.3 – Informative reliability qualification tests for passive optical components
used in category O, uncontrolled environments (sequential) . 21
Table E.1 – Failure mode and known failure mechanisms for passive optical
components (1 of 20) . 22

---------------------- Page: 9 ----------------------
SIST EN 62005-9-1:2016
– 4 – IEC 62005-9-1:2015  IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS –
RELIABILITY –

Part 9-1: Qualification of passive optical components

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62005-9-1 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/3896/FDIS 86B/3921/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 10 ----------------------
SIST EN 62005-9-1:2016
IEC 62005-9-1:2015  IEC 2015 – 5 –
It is the intent of this standard to be compatible with and work in conjunction with the
performance standards defined in the IEC 61753 series, the test and measurement standards
defined in the IEC 61300 series, and the reliability standards defined in the IEC 62005 series.
A list of all parts in the IEC 62005 series, published under the general title, Fibre optic
interconnecting and passive components – Reliability, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 11 ----------------------
SIST EN 62005-9-1:2016
– 6 – IEC 62005-9-1:2015  IEC 2015
INTRODUCTION
Qualification reliability standards define the conditions for a set of stress tests, the passing of
which suggests an acceptable level of reliability in the referenced performance categories and
operating service environments. Upon passing, the specific product tested is called qualified
to that standard. The results of these tests are attribute data, i.e. pass or fail. True reliability
prediction and quantification requires significantly greater testing.
This International Standard is meant to be a general document that can be applied to all
passive optical components, except connectors. As such, it does not and cannot cover every
possible component and application. Its application to electrically assisted non-active
components such as optical switches is under study. The stress tests are specific and
explicitly defined to establish consistency. The measurements and pass/fail criteria are not
explicitly stated in this standard; however, guidance is given in the relevant clause to
establish reasonable parameters and values. Explicit reporting requirements are defined
which include written justifications and technical support for all selected measurements and
pass/fail criteria.

---------------------- Page: 12 ----------------------
SIST EN 62005-9-1:2016
IEC 62005-9-1:2015  IEC 2015 – 7 –
FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS –
RELIABILITY –

Part 9-1: Qualification of passive optical components



1 Scope
This part of IEC 62005 establishes a general reliability qualification program that applies to all
passive fibre optic components except connectors and connector assemblies, the passing of
which, suggests a minimum level of reliability assurance and allows that specific device to be
called qualified to this standard.
The objectives of this International Standard are as follows:
– to specify the requirements for a general reliability qualification standard (RQS) for
passive optical components;
– to give direction to the supplier and to the end user on the production and purchase of
passive optical components to meet and verify reliability qualification standards for certain
specified service environments;
– to give the minimum list of reliability qualification stress tests and conditions;
– to establish guidance for the selection of appropriate measurements and pass/fail criteria;
– to give relevant references; and
– to establish the minimum reporting requirements.
This standard defines a series of stress tests, their severity, sequences, quantities of devices
under the test (DUT), acceptance criteria, and reporting requirements. It also gives guidelines
to selecting appropriate measurements and pass/fail criteria.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60749-26, Semiconductor devices – Mechanical and climatic test methods – Part 26:
Electrostatic discharge (ESD) sensitivity testing – Human body model (HBM)
IEC 61300 (all parts), Fibre optic interconnecting devices and passive components – Basic
test and measurement procedures
IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)
IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention
IEC 61300-2-9, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-9: Tests – Shock

---------------------- Page: 13 ----------------------
SIST EN 62005-9-1:2016
– 8 – IEC 62005-9-1:2015  IEC 2015
IEC 61300-2-17, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-17: Tests – Cold
IEC 61300-2-18, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-18: Tests – Dry heat – High temperature endurance
IEC 61300-2-19, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-19: Tests – Damp heat (steady state)
IEC 61300-2-22, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-22: Tests – Change of temperature
IEC 61300-2-42, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-42: Tests – Static side load for strain relief
IEC 61300-2-44, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-44: Tests – Flexing of the strain relief of fibre optic
devices
IEC 61300-2-47, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-47: Tests – Thermal shocks
IEC 61753 (all parts), Fibre optic interconnecting devices and passive components
performance standard
IEC 61753-1, Fibre optic interconnecting devices and passive components performance
standard – Part 1: General and guidance for performance standards
IEC 62005 (all parts), Fibre optic interconnecting devices and passive components –
Reliability
IEC 62005-1, Reliability of fibre optic interconnecting devices and passive components –
Part 1: Introductory guide and definitions
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 62005-1, as well as
the following apply.
3.1.1
reliability qualification stress test
RQST
test which applies a mechanical, electrical, optical, environmental or other stress or any
combination of the above to the DUT
Note 1 to entry: This note applies to the French language only.
3.1.2
lot tolerance per cent defective
LTPD
level of quality that is unsatisfactory and should be rejected by the sampling plan
Note 1 to entry: This note applies to the French language only.

---------------------- Page: 14 ----------------------
SIST EN 62005-9-1:2016
IEC 62005-9-1:2015  IEC 2015 – 9 –
3.2 Abbreviations
CD Chromatic dispersion
DUT Devices under test
ESD Electrostatic discharge
FMEA Failure mode and effect analysis
GDR Group delay ripple
HBM Human body model
LTPD Lot tolerance per cent defective
RQS Reliability qualification standard
RQST Reliability qualification stress test
TDL Temperature dependent loss
TEC Thermo-electric cooler
VIPA Virtually imaged phased array
4 General requirements
4.1 DUT
The specific passive optical component to which this standard relates shall be clearly defined.
The DUTs shall be selected randomly from a larger population of samples such that the DUTs
are representative of devices that would be shipped to the customer.
Although it is anticipated that a homogeneous set of the DUTs be used for all tests in a RQS
program, it is recognized that this is not always possible or practical. When this is the case,
generally referred to as a ‘read across’ or a ‘test by similarity’, the specific description of the
products used in each test shall be stated. Justification for every ‘read across’ and ‘test by
similarity’ shall be documented. In addition, the level of manufacturing maturity of each DUT
type shall be defined, for example, the product is in production with all documentation or the
product is in development and was made with significant engineering support.
4.2 Product family
When one model number of a family of products is qualified and qualification is subsequently
claimed for the entire family of products, the DUT shall be the model number with the most
demanding specifications. Only models with equivalent or lesser specifications than the
device tested can be called qualified. The same applies if the test result is extended to
products of lower complexity.
EXAMPLE Qualification of 1 x 8 splitters may be justified by qualification of 1 x 16 splitters if the same technology
is used.
In both cases, a technical argumentation is required to justify the qualification by similarity.
4.3 Service environments
The performance requirements for passive fibre optic components are defined in IEC 61753-1.
The relevant service environments for this standard are as follows:

---------------------- Page: 15 ----------------------
SIST EN 62005-9-1:2016
– 10 – IEC 62005-9-1:2015  IEC 2015
Table 1 – Service environments
Category Environment
C Controlled
U Uncontrolled
O Uncontrolled environment (sequential test)

In gener
...

SLOVENSKI STANDARD
SIST EN 62005-9-1:2016
01-februar-2016
2SWLþQLVSRMQLHOHPHQWLLQSDVLYQHNRPSRQHQWH=DQHVOMLYRVWGHO
.YDOLILFLUDQMHSDVLYQLKRSWLþQLKNRPSRQHQW ,(&
Fibre optic interconnecting devices and passive components - Reliability - Part 9-1:
Qualification of passive optical components (IEC 62005-9-1:2015)
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Zuverlässigkeit - Teil 9-1:
Beurteilung der passiven optischen Bauteil (IEC 62005-9-1:2015)
Dispositifs d'interconnexion et composants passifs à fibres optiques - Fiabilité - Partie 9-
1: Qualification des composants optiques passifs (IEC 62005-9-1:2015)
Ta slovenski standard je istoveten z: EN 62005-9-1:2015
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
SIST EN 62005-9-1:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD EN 62005-9-1

NORME EUROPÉENNE

EUROPÄISCHE NORM
October 2015
ICS 33.180.20

English Version
Fibre optic interconnecting devices and passive components -
Reliability - Part 9-1: Qualification of passive optical components
(IEC 62005-9-1:2015)
Dispositifs d'interconnexion et composants passifs à fibres Lichtwellenleiter - Verbindungselemente und passive
optiques - Fiabilité - Partie 9-1: Qualification des Bauteile - Zuverlässigkeit - Teil 9-1: Beurteilung der
composants optiques passifs passiven optischen Bauteile
(IEC 62005-9-1:2015) (IEC 62005-9-1:2015)
This European Standard was approved by CENELEC on 2015-07-30. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 62005-9-1:2015 E

---------------------- Page: 2 ----------------------

EN 62005-9-1:2015
European foreword
The text of document 86B/3896/FDIS, future edition 1 of IEC 62005-9-1, prepared by SC 86B "Fibre
optic interconnecting devices and passive components" of IEC/TC 86 "Fibre optics" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN 62005-9-1:2015.
The following dates are fixed:
(dop) 2016-04-30
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2018-07-30
• latest date by which the national standards conflicting with
the document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 62005-9-1:2015 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 61300-2-5 NOTE Harmonized as EN 61300-2-5.
IEC 61300-2-6 NOTE Harmonized as EN 61300-2-6.
IEC 61300-2-7 NOTE Harmonized as EN 61300-2-7.
IEC 61300-2-14 NOTE Harmonized as EN 61300-2-14.
IEC 61300-2-15 NOTE Harmonized as EN 61300-2-15.
IEC 61300-2-35 NOTE Harmonized as EN 61300-2-35.
2

---------------------- Page: 3 ----------------------

EN 62005-9-1:2015
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.

Publication Year Title EN/HD Year
IEC 60749-26 -  Semiconductor devices - Mechanical and EN 60749-26 -
climatic test methods -
Part 26: Electrostatic discharge (ESD)
sensitivity testing - Human body model
(HBM)
IEC 61300 series Fibre optic interconnecting devices and EN 61300 series
passive components - Basic test and
measurement procedures
IEC 61300-2-1 -  Fibre optic interconnecting devices and EN 61300-2-1 -
passive components - Basic test and
measurement procedures -
Part 2-1: Tests - Vibration (sinusoidal)
IEC 61300-2-4 -  Fibre optic interconnecting devices and EN 61300-2-4 -
passive components - Basic test and
measurement procedures -
Part 2-4: Tests - Fibre/cable retention
IEC 61300-2-9 -  Fibre optic interconnecting devices and EN 61300-2-9 -
passive components - Basic test and
measurement procedures -
Part 2-9: Tests - Shock
IEC 61300-2-17 -  Fibre optic interconnecting devices and EN 61300-2-17 -
passive components - Basic test and
measurement procedures -
Part 2-17: Tests - Cold
IEC 61300-2-18 -  Fibre optic interconnecting devices and EN 61300-2-18 -
passive components - Basic test and
measurement procedures -
Part 2-18: Tests - Dry heat - High
temperature endurance
IEC 61300-2-19 -  Fibre optic interconnecting devices and EN 61300-2-19 -
passive components - Basic test and
measurement procedures -
Part 2-19: Tests - Damp heat (steady state)
3

---------------------- Page: 4 ----------------------

EN 62005-9-1:2015
Publication Year Title EN/HD Year
IEC 61300-2-22 -  Fibre optic interconnecting devices and EN 61300-2-22 -
passive components - Basic test and
measurement procedures -
Part 2-22: Tests - Change of temperature
IEC 61300-2-42 -  Fibre optic interconnecting devices and EN 61300-2-42 -
passive components - Basic test and
measurement procedures -
Part 2-42: Tests - Static side load for strain
relief
IEC 61300-2-44 -  Fibre optic interconnecting devices and EN 61300-2-44 -
passive components - Basic test and
measurement procedures -
Part 2-44: Tests - Flexing of the strain relief
of fibre optic devices
IEC 61300-2-47 -  Fibre optic interconnecting devices and EN 61300-2-47 -
passive components - Basic test and
measurement procedures -
Part 2-47: Tests - Thermal shocks
IEC 61753 series Fibre optic interconnecting devices and EN 61753 series
passive components - Performance
standard
IEC 61753-1 -  Fibre optic interconnecting devices and EN 61753-1 -
passive components performance
standard -
Part 1: General and guidance for
performance standards
IEC 62005 series Fibre optic interconnecting devices and EN 62005 series
passive components - Reliability
IEC 62005-1 -  Reliability of fibre optic interconnecting EN 62005-1 -
devices and passive components -
Part 1: Introductory guide and definitions

4

---------------------- Page: 5 ----------------------

IEC 62005-9-1

®


Edition 1.0 2015-06




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE











Fibre optic interconnecting devices and passive components – Reliability –

Part 9-1: Qualification of passive optical components




Dispositifs d'interconnexion et composants passifs à fibres optiques –

Fiabilité –

Partie 9-1: Qualification des composants optiques passifs















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 33.180.20 ISBN 978-2-8322-2749-7



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 6 ----------------------

– 2 – IEC 62005-9-1:2015  IEC 2015
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references. 7
3 Terms, definitions and abbreviations . 8
3.1 Terms and definitions . 8
3.2 Abbreviations . 9
4 General requirements . 9
4.1 DUT . 9
4.2 Product family . 9
4.3 Service environments . 9
5 Tests . 10
5.1 General . 10
5.2 Quantity of the DUTs . 10
5.3 Sequence . 10
5.4 Acceptance criteria . 10
5.5 Test methods . 10
5.6 Severity . 11
6 Measurements . 11
6.1 General . 11
6.2 Measurements . 11
6.3 Pass/fail criteria . 11
6.4 Measurement methods . 11
6.5 Required leak rate and residual gas analysis measurements . 11
7 Report . 11
Annex A (normative)  Required reliability qualification tests for passive optical
components used in category C, controlled environments . 13
Annex B (normative) Required reliability qualification tests for passive optical
components used in category U, uncontrolled environments . 15
Annex C (normative) Required reliability qualification tests for passive optical
components used in category O, uncontrolled environments (sequential) . 16
Annex D (informative) Informative and optional reliability qualification tests for passive
optical components used in category C, category U and category O environments . 18
D.1 Informative and optional reliability qualification tests for passive optical
components used in category C, controlled environments . 18
D.2 Optional reliability qualification tests for passive optical components used in
category U, uncontrolled environments . 20
D.3 Informative reliability qualification tests for passive optical components used
in category O, uncontrolled environments (sequential) . 20
Annex E (informative) Failure mode and known failure mechanisms for passive optical
components . 22
Bibliography . 42

Table 1 – Service environments . 10
Table A.1 – Required reliability qualification tests for passive optical components used
in category C, controlled environments (1 of 2) . 13

---------------------- Page: 7 ----------------------

IEC 62005-9-1:2015  IEC 2015 – 3 –
Table B.1 – Required reliability qualification tests for passive optical components used
in category U, uncontrolled environments . 15
Table C.1 – Required reliability qualification tests for passive optical components used
in category O, uncontrolled environments (sequential) (1 of 2) . 16
Table D.1 – Informative and optional reliability qualification tests for passive optical
components used in category C, controlled environments (1 of 2) . 18
Table D.2 – Optional reliability qualification tests for passive optical components used
in category U, uncontrolled environments . 20
Table D.3 – Informative reliability qualification tests for passive optical components
used in category O, uncontrolled environments (sequential) . 21
Table E.1 – Failure mode and known failure mechanisms for passive optical
components (1 of 20) . 22

---------------------- Page: 8 ----------------------

– 4 – IEC 62005-9-1:2015  IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS –
RELIABILITY –

Part 9-1: Qualification of passive optical components

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62005-9-1 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/3896/FDIS 86B/3921/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 9 ----------------------

IEC 62005-9-1:2015  IEC 2015 – 5 –
It is the intent of this standard to be compatible with and work in conjunction with the
performance standards defined in the IEC 61753 series, the test and measurement standards
defined in the IEC 61300 series, and the reliability standards defined in the IEC 62005 series.
A list of all parts in the IEC 62005 series, published under the general title, Fibre optic
interconnecting and passive components – Reliability, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 10 ----------------------

– 6 – IEC 62005-9-1:2015  IEC 2015
INTRODUCTION
Qualification reliability standards define the conditions for a set of stress tests, the passing of
which suggests an acceptable level of reliability in the referenced performance categories and
operating service environments. Upon passing, the specific product tested is called qualified
to that standard. The results of these tests are attribute data, i.e. pass or fail. True reliability
prediction and quantification requires significantly greater testing.
This International Standard is meant to be a general document that can be applied to all
passive optical components, except connectors. As such, it does not and cannot cover every
possible component and application. Its application to electrically assisted non-active
components such as optical switches is under study. The stress tests are specific and
explicitly defined to establish consistency. The measurements and pass/fail criteria are not
explicitly stated in this standard; however, guidance is given in the relevant clause to
establish reasonable parameters and values. Explicit reporting requirements are defined
which include written justifications and technical support for all selected measurements and
pass/fail criteria.

---------------------- Page: 11 ----------------------

IEC 62005-9-1:2015  IEC 2015 – 7 –
FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS –
RELIABILITY –

Part 9-1: Qualification of passive optical components



1 Scope
This part of IEC 62005 establishes a general reliability qualification program that applies to all
passive fibre optic components except connectors and connector assemblies, the passing of
which, suggests a minimum level of reliability assurance and allows that specific device to be
called qualified to this standard.
The objectives of this International Standard are as follows:
– to specify the requirements for a general reliability qualification standard (RQS) for
passive optical components;
– to give direction to the supplier and to the end user on the production and purchase of
passive optical components to meet and verify reliability qualification standards for certain
specified service environments;
– to give the minimum list of reliability qualification stress tests and conditions;
– to establish guidance for the selection of appropriate measurements and pass/fail criteria;
– to give relevant references; and
– to establish the minimum reporting requirements.
This standard defines a series of stress tests, their severity, sequences, quantities of devices
under the test (DUT), acceptance criteria, and reporting requirements. It also gives guidelines
to selecting appropriate measurements and pass/fail criteria.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60749-26, Semiconductor devices – Mechanical and climatic test methods – Part 26:
Electrostatic discharge (ESD) sensitivity testing – Human body model (HBM)
IEC 61300 (all parts), Fibre optic interconnecting devices and passive components – Basic
test and measurement procedures
IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)
IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention
IEC 61300-2-9, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-9: Tests – Shock

---------------------- Page: 12 ----------------------

– 8 – IEC 62005-9-1:2015  IEC 2015
IEC 61300-2-17, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-17: Tests – Cold
IEC 61300-2-18, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-18: Tests – Dry heat – High temperature endurance
IEC 61300-2-19, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-19: Tests – Damp heat (steady state)
IEC 61300-2-22, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-22: Tests – Change of temperature
IEC 61300-2-42, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-42: Tests – Static side load for strain relief
IEC 61300-2-44, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-44: Tests – Flexing of the strain relief of fibre optic
devices
IEC 61300-2-47, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-47: Tests – Thermal shocks
IEC 61753 (all parts), Fibre optic interconnecting devices and passive components
performance standard
IEC 61753-1, Fibre optic interconnecting devices and passive components performance
standard – Part 1: General and guidance for performance standards
IEC 62005 (all parts), Fibre optic interconnecting devices and passive components –
Reliability
IEC 62005-1, Reliability of fibre optic interconnecting devices and passive components –
Part 1: Introductory guide and definitions
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 62005-1, as well as
the following apply.
3.1.1
reliability qualification stress test
RQST
test which applies a mechanical, electrical, optical, environmental or other stress or any
combination of the above to the DUT
Note 1 to entry: This note applies to the French language only.
3.1.2
lot tolerance per cent defective
LTPD
level of quality that is unsatisfactory and should be rejected by the sampling plan
Note 1 to entry: This note applies to the French language only.

---------------------- Page: 13 ----------------------

IEC 62005-9-1:2015  IEC 2015 – 9 –
3.2 Abbreviations
CD Chromatic dispersion
DUT Devices under test
ESD Electrostatic discharge
FMEA Failure mode and effect analysis
GDR Group delay ripple
HBM Human body model
LTPD Lot tolerance per cent defective
RQS Reliability qualification standard
RQST Reliability qualification stress test
TDL Temperature dependent loss
TEC Thermo-electric cooler
VIPA Virtually imaged phased array
4 General requirements
4.1 DUT
The specific passive optical component to which this standard relates shall be clearly defined.
The DUTs shall be selected randomly from a larger population of samples such that the DUTs
are representative of devices that would be shipped to the customer.
Although it is anticipated that a homogeneous set of the DUTs be used for all tests in a RQS
program, it is recognized that this is not always possible or practical. When this is the case,
generally referred to as a ‘read across’ or a ‘test by similarity’, the specific description of the
products used in each test shall be stated. Justification for every ‘read across’ and ‘test by
similarity’ shall be documented. In addition, the level of manufacturing maturity of each DUT
type shall be defined, for example, the product is in production with all documentation or the
product is in development and was made with significant engineering support.
4.2 Product family
When one model number of a family of products is qualified and qualification is subsequently
claimed for the entire family of products, the DUT shall be the model number with the most
demanding specifications. Only models with equivalent or lesser specifications than the
device tested can be called qualified. The same applies if the test result is extended to
products of lower complexity.
EXAMPLE Qualification of 1 x 8 splitters may be justified by qualification of 1 x 16 splitters if the same technology
is used.
In both cases, a technical argumentation is required to justify the qualification by similarity.
4.3 Service environments
The performance requirements for passive fibre optic components are defined in IEC 61753-1.
The relevant service environments for this standard are as follows:

---------------------- Page: 14 ----------------------

– 10 – IEC 62005-9-1:2015  IEC 2015
Table 1 – Service environments
Category Environment
C Controlled
U Uncontrolled
O Uncontrolled environment (sequential test)

In general, conducting a test to a more severe condition shall be regarded as having satisfied
the criteria for a less severe condition, thus eliminating the need for redundant testing.
Testing to a service environment of greater severity than that contained in Table 1 is not part
of the current issue of this RQST.
5 Tests
5.1 General
Three types of tests are defined in Annex A, B, C and D. T
...