SIST EN 300 019-2-3 V2.1.2:2006
(Main)Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-3: Specification of environmental tests; Stationary use at weatherprotected locations
Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-3: Specification of environmental tests; Stationary use at weatherprotected locations
The present document specifies test severities and methods for the verification of the required resistibility of equipment according to the relevant environmental class. The tests in Part 2-3 of this multi-part EN apply to stationary use of equipment at weatherprotected locations covering the environmental conditions stated in ETS 300 019-1-3 [1].
Inženiring opreme (EE) – Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo – 2-3. del: Specifikacija preskusov vplivov okolja – Fiksna uporaba na lokacijah, zaščitenih pred vremenskimi vplivi
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2006
,QåHQLULQJRSUHPH((±2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMDQD
WHOHNRPXQLNDFLMVNRRSUHPR±GHO6SHFLILNDFLMDSUHVNXVRYYSOLYRYRNROMD±
)LNVQDXSRUDEDQDORNDFLMDK]DãþLWHQLKSUHGYUHPHQVNLPLYSOLYL
Equipment Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 2-3: Specification of environmental tests; Stationary
use at weatherprotected locations
Ta slovenski standard je istoveten z: EN 300 019-2-3 Version 2.1.2
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
ETSI EN 300 019-2-3 V2.1.2 (1999-09)
European Standard (Telecommunications series)
Equipment Engineering (EE);
Environmental conditions and environmental tests for
telecommunications equipment;
Part 2-3: Specification of environmental tests;
Stationary use at weatherprotected locations
2 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Reference
REN/EE-01027-2-3 (06cis0dc.PDF)
Keywords
environment
ETSI
Postal address
F-06921 Sophia Antipolis Cedex - FRANCE
Office address
650 Route des Lucioles - Sophia Antipolis
Valbonne - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Internet
secretariat@etsi.fr
Individual copies of this ETSI deliverable
can be downloaded from
http://www.etsi.org
If you find errors in the present document, send your
comment to: editor@etsi.fr
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1999.
All rights reserved.
ETSI
3 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Contents
Intellectual Property Rights . 5
Foreword. 5
1 Scope. 6
2 References . 6
3 Environmental test specifications. 6
3.1 Specifications T 3.1 and T 3.1 E: Temperature-controlled locations. 7
3.2 Specification T 3.2: Partly temperature-controlled locations. 11
3.3 Specification T 3.3: Not temperature-controlled locations . 14
3.4 Specification T 3.4: Sites with heat-trap. 17
3.5 Specification T 3.5: Sheltered locations . 20
4 Earthquake test specification. 23
4.1 Vibration response investigation. 23
4.2 Test conditioning . 24
5 Notes to tables . 25
5.1 General note. 25
5.2 Notes to tables 1 to 12 . 25
Annex A (normative): Alternative climatic test method for class 3.1. 29
A.1 Description. 29
A.2 Objectives . 29
A.3 Test apparatus. 29
A.4 Methodology. 29
A.5 Pre-conditioning . 29
A.6 Testing . 30
A.6.1 Equipment operation. 30
A.6.2 Equipment failures. 30
A.6.3 Test severities . 30
A.6.4 Scanning the climatogram. 31
A.6.5 Rates of change. 31
A.6.6 Functional requirements and verification. 31
Annex B (normative): Alternative climatic test method for class 3.2. 32
B.1 Description. 32
B.2 Objectives . 32
B.3 Test apparatus. 32
B.4 Methodology. 32
B.5 Pre-conditioning . 33
B.6 Testing . 33
B.6.1 Equipment operation. 33
B.6.2 Equipment failures. 33
B.6.3 Test severities . 33
B.6.4 Scanning the climatogram. 33
B.6.5 Rates of change. 34
B.6.6 Functional requirements and verification. 34
ETSI
4 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Annex C (normative): Alternative climatic test method for class 3.3. 35
C.1 Description. 35
C.2 Objectives . 35
C.3 Test apparatus. 35
C.4 Methodology. 35
C.5 Pre-conditioning . 36
C.6 Testing . 36
C.6.1 Equipment operation. 36
C.6.2 Equipment failures. 36
C.6.3 Test severities . 36
C.6.4 Scanning the climatogram. 36
C.6.5 Rates of change. 37
C.6.6 Functional requirements and verification. 37
Annex D (normative): Alternative climatic test method for class 3.4. 38
D.1 Description. 38
D.2 Objectives . 38
D.3 Test apparatus. 38
D.4 Methodology. 38
D.5 Pre-conditioning . 39
D.6 Testing . 39
D.6.1 Equipment operation. 39
D.6.2 Equipment failures. 39
D.6.3 Test severities . 39
D.6.4 Scanning the climatogram. 40
D.6.5 Rates of change. 40
D.6.6 Functional requirements and verification. 40
Annex E (normative): Alternative climatic test method for class 3.5. 41
E.1 Description. 41
E.2 Objectives . 41
E.3 Test apparatus. 41
E.4 Methodology. 41
E.5 Pre-conditioning . 42
E.6 Testing . 42
E.6.1 Equipment operation. 42
E.6.2 Equipment failures. 42
E.6.3 Test severities . 42
E.6.4 Scanning the climatogram. 43
E.6.5 Rates of change. 43
E.6.6 Functional requirements and verification. 43
Bibliography . 44
History. 45
ETSI
5 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect
of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server
(http://www.etsi.org/ipr).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)
which are, or may be, or may become, essential to the present document.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document consists of 2 parts as follows:
Part 1: "Classification of environmental conditions";
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use.
Part 2: "Specification of environmental tests".
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
Each part of the standard is divided into sub-parts. Sub-part 2-0 forms a general overview of Part 2.
This sub-part 2-3 deals with stationary use at weatherprotected locations.
National transposition dates
Date of adoption of this EN: 3 September 1999
Date of latest announcement of this EN (doa): 31 December 1999
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 30 June 2000
Date of withdrawal of any conflicting National Standard (dow): 30 June 2000
ETSI
6 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
1 Scope
The present document specifies test severities and methods for the verification of the required resistibility of equipment
according to the relevant environmental class.
The tests in Part 2-3 of this multi-part EN apply to stationary use of equipment at weatherprotected locations covering
the environmental conditions stated in ETS 300 019-1-3 [1].
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication, edition number, version number, etc.) or non-
specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
• A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the same
number.
[1] ETS 300 019-1-3: "Equipment Engineering (EE); Environmental conditions and environmental
tests for telecommunications equipment; Part 1-3: Classification of environmental conditions;
Stationary use at weatherprotected locations".
[2] IEC 60068-2: "Environmental testing - Part 2: Tests".
[3] ETS 300 019-2-0: "Equipment Engineering (EE); Environmental conditions and environmental
tests for telecommunications equipment; Part 2-0: Specification of environmental tests;
Introduction".
[4] IEC 60721-3-3: "Classification of environmental conditions - Part 3: Classification of groups of
environmental parameters and their severities - Section 3: Stationary use at weatherprotected
locations".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are in clauses 4 and 5 of ETS 300 019-1-3 [1].
ETS 300 019-2-0 [3] forms a general overview of Part 2 of the present document.
The equipment under test is assumed to be in its operational state throughout the test conditions described in this part
unless otherwise stated. The required performance before, during and after the test needs to be specified in the product
specification. Input and load conditions of the equipment shall be chosen to obtain full utilization of the equipment
under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where it shall be
minimized.
ETSI
7 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
3.1 Specifications T 3.1 and T 3.1 E: Temperature-controlled locations
Specification T 3.1: Temperature-controlled locations - normal operating conditions.
This specification applies to permanently temperature-controlled enclosed locations where humidity is usually not controlled. See tables 1 and 2.
Table 1: Test specification T 3.1: Temperature-controlled locations - climatic tests
Environmental parameter Environmental Environmental test specification T3.1: In-use,
Class 3.1 Temperature-controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) +5 +5 16 h IEC 60068-2-1 Ab/Ad: Cold 1, 21
Air high (°C) +40 +40 or +50 16 h IEC 60068-2-2 Bb/Bd: Dry heat 2, 21
temperature
change (°C) +25/+40 half cycle IEC 60068-2-14 Nb: Change of 3, 21
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 5 none 4, 21
relative high (%) 85 85 4 d IEC 60068-2-56 Cb: Damp heat steady 5, 21
(°C) +30 state
Humidity condensation no
low (g/m ) 1 none 4, 21
absolute
high (g/m)25 7, 21
pressure low (kPa) 70 none 8
Air high (kPa) 106 none 8
speed (m/s) 5,0 none 4
rain intensity no
Water low temperature no
other sources no
icing & frosting no
Radiation solar (W/m ) 700 10
heat (W/m ) 600 11
ETSI
8 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Environmental parameter Environmental Environmental test specification T3.1: In-use,
Class 3.1 Temperature-controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
sulphur SO2 (mg/m ) 0,3/1,0 none 12
H2S (mg/m ) 0,1/0,5 none 12
salt mist sea and road salt none 12
Chemically chlorine Cl (mg/m ) 0,1/0,3 none 12
active HCI (mg/m ) 0,1/0,5 none 12
substances nitrogen NOx (mg/m ) 0,5/1,0 none 12
NH (mg/m ) 1,0/3,0 none 12
hydrogen fluoride (mg/m ) 0,01/0,03 none 12
HF
ozone O (mg/m ) 0,05/0,1 none 12
Mechanically dust sedimentation 1,5 none 12
(mg/(m h))
active suspension (mg/m ) 0,2 none 13
substances sand (mg/m ) 30 none 13
Flora and micro organisms negligible
fauna rodents, insects negligible
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
9 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Table 2: Test specification T 3.1: Temperature-controlled locations - mechanical tests
Environmental parameter Environmental Environmental test specification T 3.1: In-use,
Class 3.1 Temperature-controlled locations
Type Parameter Detail Characteristic Test severity Duration Reference Method Notes
parameter severity
Vibration sinusoidal displacement (mm) 0,3 15
acceleration (m/s ) 1,0 none
frequency range (Hz) 2-9 9-200
axes of vibration
Shocks shocks shock spectrum Type L half sine IEC Ea: Shock 18
duration (ms) 22 11 60068-2-27
acceleration (m/s ) 40 30
number of shocks 3 in each direction
direction of shocks 6
NOTE 1: none = verification is required only in special cases
NOTE 2: n = number of note, see clause 5.
Specification T 3.1 E: Temperature-controlled locations - exceptional operating conditions.
This specification applies to permanently temperature-controlled locations where humidity is usually not controlled. The reference class is the same as for T 3.1, but the test
specification relates to reduced performance requirements. See table 3.
ETSI
10 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Table 3: Test specification T 3.1 E: Temperature-controlled locations, exceptional operating conditions - climatic tests
Environmental parameter Environmental Environmental test specification T3.1E: In-use,
Class 3.1E Temperature-controlled locations - Exceptional.
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) -5 -5 16 h IEC 60068-2-1 Ab/Ad: Cold 1; 21
Air high (°C) +45 +45 or +55 16 h IEC 60068-2-2 Bb/Bd: Dry heat 2; 21
temperature
change (°C) +25/+45 half cycle IEC 60068-2-14 Nb: Change of 3; 21
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 5 none 4, 21
relative high (%) 90 93 4 d IEC 60068-2-56 Cb: Damp heat 5; 21
(°C) +30 steady state
Humidity condensation no
absolute low (g/m ) 1 none 4, 21
high (g/m )25 7, 21
Radiation solar (W/m ) 700 10
heat (W/m ) 600 11
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
11 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
3.2 Specification T 3.2: Partly temperature-controlled locations
This specification applies to enclosed locations having neither temperature nor humidity control, but where heating may be used to avoid low temperatures. The building
construction avoids extremely high temperatures. See tables 4 and 5.
Table 4: Test specification T 3.2: Partly temperature-controlled locations - climatic tests
Environmental parameter Environmental Environmental test specification T3.2: In-use,
Class 3.2 Partly temperature-controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) -5 -5 16 h IEC 60068-2-1 Ab/Ad: Cold 1, 22
Air high (°C) +45 +45 or +55 16 h IEC 60068-2-2 Bb/Bd: Dry heat 2, 22
temperature change temp range (°C) +25/+55 or half cycle IEC 60068-2-14 Nb: Change of 3, 22
+25/+45 t = 3 h temperature
rate (°C/min) 0,5 0,5
low (%) 5 none 4, 22
high (%) 95 93 4 d IEC 60068-2-56 Cb: Damp heat 5, 22
relative (°C) +30 steady state
Humidity condensation yes IEC 60068-2-30 Db: Damp heat 6, 22
(°C) +30° 1 cycle cyclic
(%) 90-100 Variant 1
absolute low (g/m ) 1 none 4, 22
high (g/m )29 7, 22
pressure low (kPa) 70 none 8
Air high (kPa) 106 none 8
speed (m/s) 5,0 none 4
rain intensity no
Water low temperature no
other sources no
icing & frosting yes 4
Radiation solar (W/m ) 700 10
heat (W/m ) 600 11
ETSI
12 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Environmental parameter Environmental Environmental test specification T3.2: In-use,
Class 3.2 Partly temperature-controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
sulphur SO (mg/m ) 0,3/1,0 none 12
H S (mg/m ) 0,1/0,5 none 12
salt mist sea and road salt none 12
Chemically chlorine Cl2 (mg/m ) 0,1/0,3 none 12
active HCl (mg/m ) 0,1/0,5 none 12
substances nitrogen NOx (mg/m ) 0,5/5,0 none 12
NH (mg/m ) 1,0/3,0 none 12
hydrogen fluoride (mg/m ) 0,01/0,03 none 12
HF
ozone O (mg/m ) 0,05/0,1 none 12
Mechanically dust sedimentation 15 13
(mg/(m h))
active suspension (mg/m ) 0,4 13
substances sand (mg/m ) 300 13
Flora and micro organisms mould, fungus, etc. none 14
fauna rodents, insects rodents, etc. none 14
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
13 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Table 5: Test specification T 3.2: Partly temperature-controlled locations - mechanical tests
Environmental parameter Environmental Environmental test specification T 3.2: In-use,
Class 3.2 Partly temperature-controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
Vibration sinusoidal velocity (mm/s) 5 IEC 60068-2-6 Fc: Vibration 16
displacement (mm) 1,5 (sinusoidal)
acceleration (m/s ) 5 2
frequency range (Hz) 2-9 9-200 5-62 62-200 3 x 5 sweep
axes of vibration 3 cycles
2 3
ASD (m /s ) 0,02 IEC 60068-2-64 Fh: Vibration, 17
random (dB/oct) +12 -12 3 x 30 minutes broad-band random
frequency range (Hz) 5-10 10-50 50-100 (digital control)
axes of vibration 3
Shocks shocks shock spectrum Type L half sine IEC 60068-2-27 Ea: Shock 18
duration (ms) 22 11
acceleration (m/s ) 40 30
number of shocks 3 in each
directions of shocks 6 direction
NOTE: n = number of note, see clause 5.
ETSI
14 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
3.3 Specification T 3.3: Not temperature-controlled locations
This specification applies to weatherprotected or partially weatherprotected locations having neither temperature nor humidity control. See tables 6 and 7.
Table 6: Test specification T 3.3: Not temperature-controlled locations - climatic tests
Environmental parameter Environmental Environmental test specification T3.3: In-use,
Class 3.3 Not temperature-controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) -25 -25 16 h IEC 60068-2-1 Ab/Ad: Cold 1, 23
Air high (°C) +55 +55 or +70 16 h IEC 60068-2-2 Bb/Bd: Dry heat 2, 23
temperature change (°C) -5/+45 1 cycle IEC Nb: Change of 3, 23
(°C/min) 0,5 0,5 t = 3 h 60068-2-14 temperature
low (%) 10 none 4, 23
high (%) 100 93 4 d IEC Cb: Damp heat 5, 23
relative (°C) +30 60068-2-56 steady state
condensation yes IEC Db: Damp heat 6, 23
Humidity (%) 90-100 2 cycles 60068-2-30 cyclic Variant 1
(°C) +30
absolute low (g/m ) 0,5 none 4, 23
high (g/m)29 7, 23
pressure low (kPa) 70 none 8
Air high (kPa) 106 none 8
speed (m/s) 5,0 none 4
rain intensity wind driven 9
Water low temperature no
other sources dripping water 4
icing & frosting yes 4
Radiation solar (W/m ) 1 200 10
heat (W/m ) 600 11
ETSI
15 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Environmental parameter Environmental Environmental test specification T3.3: In-use,
Class 3.3 Not temperature-controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
sulphur SO (mg/m ) 0,3/1,0 none 12
H S (mg/m ) 0,1/0,5 none 12
salt mist sea and road salt none 12
Chemically chlorine Cl2 (mg/m ) 0,1/0,3 none 12
active HCl (mg/m ) 0,1/0,5 none 12
substances nitrogen NOx (mg/m ) 0,5/1,0 none 12
NH (mg/m ) 1,0/3,0 none 12
hydrogen fluoride (mg/m ) 0,01/0,03 none 12
HF
ozone O (mg/m ) 0,05/0,1 none 12
Mechanically dust sedimentation 15 13
(mg/(m h))
active suspension (mg/m ) 0,4 13
substances sand (mg/m ) 300 13
Flora and micro organisms mould, fungus, etc. none 14
fauna rodents, insects rodents, etc. none 14
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
16 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Table 7: Test specification T 3.3: Not temperature-controlled locations - mechanical tests
Environmental parameter Environmental Environmental test specification T 3.3: In-use,
Class 3.3 Not temperature-controlled locations
Type Parameter Detail Characteristic Test severity Duration Reference Method Notes
parameter severity
velocity (mm/s) 5 IEC 60068-2-6 Fc: Vibration 16
displacement (mm) 1,5 (sinusoidal)
sinusoidal acceleration (m/s ) 5 2
frequency range (Hz) 2-9 9-200 5-62 62-200 3 x 5 sweep
axes of vibration 3 cycles
Vibration
2 3
ASD (m /s ) 0,02 IEC 60068-2-64 Fh: Vibration, 17
(dB/oct) +12 -12 3 x 30 minutes broad-band random
random frequency range (Hz) 5-10 10-50 50-100 (digital control)
axes of vibration 3
shock spectrum Type L half sine IEC 60068-2-27 Ea: Shock 18
duration (ms) 22 11
Shocks shocks acceleration (m/s ) 40 30
number of shocks 3 in each direction
directions of shocks 6
NOTE: n = number of note, see clause 5.
ETSI
17 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
3.4 Specification T 3.4: Sites with heat-trap
This specification applies to weatherprotected or partially weatherprotected locations having neither temperature nor humidity control. Solar radiation and heat-trap conditions
may cause high temperatures. See tables 8 and 9.
Table 8: Test specification T 3.4: Sites with heat-trap - climatic tests
Environmental parameter Environmental Environmental test specification T3.4: In-use,
Class 3.4 Sites with heat trap
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) -40 -40 16 h IEC 60068-2-1 Ab/Ad: Cold 1, 24
Air high (°C) +70 +70 or +85 16 h IEC 60068-2-2 Bb/Bd: Dry heat 2, 24
temperature
change (°C) -5/+45 2 cycles IEC 60068-2-14 Nb: Change of 3, 24
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 10 none 4, 24
high (%) 100 93 4 d IEC 60068-2-56 Cb: Damp heat 5, 24
relative (°C) +35 steady state
Humidity condensation yes 6, 24
(%) 90-100 2 cycles IEC 60068-2-30 Db: Damp heat cyclic
(°C) +30 Variant 1
absolute low (g/m ) 0,1 none 4, 24
high (g/m )35 7, 24
pressure low (kPa) 70 none 8
Air high (kPa) 106 none 8
speed (m/s) 5,0 none 4
Water rain intensity wind driven 9
low temperature no
other sources dripping and spraying 4
water
icing & frosting yes 4
Radiation solar (W/m ) 1 200 10
heat (W/m ) 600 11
ETSI
18 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Environmental parameter Environmental Environmental test specification T3.4: In-use,
Class 3.4 Sites with heat trap
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
sulphur SO (mg/m ) 0,3/1,0 none 12
H S (mg/m ) 0,1/0,5 none 12
salt mist sea and road salt none 12
Chemically chlorine Cl2 (mg/m ) 0,1/0,3 none 12
active HCl (mg/m ) 0,1/0,5 none 12
substances nitrogen NOx (mg/m ) 0,5/1,0 none 12
NH (mg/m ) 1,0/3,0 none 12
hydrogen fluoride (mg/m ) 0,01/0,03 none 12
HF
ozone O (mg/m ) 0,05/0,1 none 12
Chemically dust sedimentation 15 13
(mg/(m h))
active suspension (mg/m ) 0,4 13
substances sand (mg/m ) 300 13
Flora and micro organisms mould, fungus, etc. none 14
fauna rodents, insects rodents, etc. none 14
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
19 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Table 9: Test specification T 3.4: Sites with heat-trap - mechanical tests
Environmental parameter Environmental Environmental test specification T 3.4: Stationary use,
Class 3.4 Sites with heat-trap
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
displacement (mm) 3,0 1,2 IEC 60068-2-6 Fc: Vibration 16, 19
sinusoidal acceleration (m/s ) 10 4 (sinusoidal)
frequency range (Hz) 2-9 9-200 5-9 9-200 3 x 5 sweep cycles
Vibration axes of vibration 3
2 3
ASD (m /s ) 0,04 IEC Fh: Vibration, 17, 19
IEC 60721-3-3
Class 3M5 random (dB/oct) +12 -12 3 x 30 minutes 60068-2-64 broad-band random
frequency range (Hz) 5-10 10-50 50-100 (digital control)
axes of vibration 3
shock spectrum Type II half sine IEC Eb: Bump 18, 19
Shocks duration (ms) 6 11 60068-2-29
shocks acceleration (m/s ) 250 50
IEC 60721-3-3
number of bumps 100 in each direction
Class 3M5
directions of bumps 6
velocity (mm/s) 5 IEC 60068-2-6 Fc: Vibration 16, 19
displacement (mm) 1,5 (sinusoidal)
sinusoidal acceleration (m/s ) 5 2 3 x 5 sweep cycles
frequency range (Hz) 2-9 9-200 5-62 62-200
Vibration axes of vibration 3
2 3
ASD (m /s ) 0,02 IEC Fh: Vibration, 17, 19
IEC 60721-3-3
random (dB/oct) +12 -12 3 x 30 minutes 60068-2-64 broad-band random
Class 3M3
frequency range (Hz) 5-10 10-50 50-100 (digital control)
axes of vibration 3
shock spectrum Type L half sine IEC Ea: Shock 18, 19
Shocks duration (ms) 22 11 60068-2-27
shocks acceleration (m/s ) 70 30
IEC 60721-3-3
number of shocks 3 in each direction
Class 3M3
directions of shocks 6
NOTE: n = number of note, see clause 5.
ETSI
20 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
3.5 Specification T 3.5: Sheltered locations
This specification applies to sheltered locations where direct solar radiation and heat-trap conditions do not exist. See tables 10 and 11.
Table 10: Test specification T 3.5: Sheltered locations - climatic tests
Environmental parameter Environmental Environmental test specification T3.5: In-use,
Class 3.5 Sheltered locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) -40 -40 16 h IEC 60068-2-1 Ab/Ad: Cold 1, 25
Air high (°C) +40 +40 16 h IEC 60068-2-2 Bb/Bd: Dry heat 2, 25
temperature change (°C) -40/+40 2 cycles IEC 60068-2-14 Nb: Change of 3, 25
(°C/min) 1,0 1,0 t = 3 h temperature
low (%) 10 none 4, 25
high (%) 100 93 4 d IEC 60068-2-56 Cb: Damp heat 5, 25
relative (°C) +35 steady state
Humidity condensation yes IEC 60068-2-30 Db: Damp heat cyclic 6, 25
(%) 90-100 2 cycles Variant 1
(°C) +35
absolute low (g/m ) 0,1 none 4, 25
high (g/m )35 7, 25
pressure low (kPa) 70 none 8
Air high (kPa) 106 none 8
speed (m/s) 30 none 4
rain intensity wind driven 9
low temperature no
Water other sources dripping and spraying 9
water
icing & frosting yes 4
Radiation solar (W/m )no
heat (W/m ) 600 none
ETSI
21 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Environmental parameter Environmental Environmental test specification T3.5: In-use,
Class 3.5 Sheltered locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
sulphur SO (mg/m ) 0,3/1,0 none 12
H S (mg/m ) 0,1/0,5 none 12
salt mist sea and road salt none 12
Chemically chlorine Cl2 (mg/m ) 0,1/0,3 none 12
active HCl (mg/m ) 0,1/0,5 none 12
substances nitrogen NOx (mg/m ) 0,5/1,0 none 12
NH (mg/m ) 1,0/3,0 none 12
hydrogen fluoride (mg/m ) 0,01/0,03 none 12
HF
ozone O (mg/m ) 0,05/0,1 none 12
Mechanical dust sedimentation 15 13
(mg/(m h))
active suspension (mg/m ) 0,4 13
substances sand (mg/m ) 300 13
Flora and micro organisms mould, fungus, etc. none 14
fauna rodents, insects rodents, etc. none 14
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
22 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
Table 11: Test specification T 3.5: Sheltered locations - mechanical tests
Environmental parameter Environmental Environmental test specification T 3.5: In-use,
Class 3.5 Sheltered locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
displacement (mm) 3,0 1,2 IEC 60068-2-6 Fc: Vibration 16, 19
sinusoidal acceleration (m/s ) 10 4 (sinusoidal)
frequency range (Hz) 2-9 9-200 5-9 9-200 3 x 5 sweep cycles
Vibration axes of vibration 3
2 3
ASD (m /s ) 0,04 IEC Fh: Vibration, 17, 19
IEC 60721-3-3
Class 3M5 random (dB/oct) +12 -12 3 x 30 minutes 60068-2-64 broad-band
frequency range (Hz) 5-10 10-50 50-100 random
axes of vibration 3 (digital control)
shock spectrum Type II half sine IEC Eb: Bump 18, 19
Shocks duration (ms) 6 11 60068-2-29
shocks acceleration (m/s ) 250 50
IEC 60721-3-3
number of bumps 100 in each
Class 3M5
directions of bumps 6 direction
velocity (mm/s) 5 IEC 60068-2-6 Fc: Vibration 16, 19
sinusoidal displacement (mm) 1,5 (sinusoidal)
acceleration (m/s ) 5 2 3 x 5 sweep cycles
frequency range (Hz) 2-9 9-200 5-62 62-200
Vibration axes of vibration 3
2 3
ASD (m /s ) 0,02 IEC Fh: Vibration, 17, 19
IEC 60721-3-3
random (dB/oct) +12 -12 3 x 30 minutes 60068-2-64 broad-band
Class 3M3
frequency range (Hz) 5-10 10-50 50-100 random
axes of vibration 3 (digital control)
shock spectrum Type L half sine IEC Ea: Shock 18, 19
Shocks duration (ms) 22 11 60068-2-27
shocks acceleration (m/s ) 70 30
IEC 60721-3-3
number of shocks 3 in each direction
Class 3M3
directions of shocks 6
NOTE: n = number of note, see clause 5.
ETSI
23 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
4 Earthquake test specification
If earthquake conditions are specified by the customer, the earthquake test requirements stated below shall be applied.
The test specification is applicable to classes 3.1 to 3.5.
4.1 Vibration response investigation
A preliminary vibration response investigation shall be carried out to determine the lowest resonant frequency of the mounted
test specimen.
The vibration response investigation can be carried out by means of sine sweep testing or random testing.
When using the sine sweep testing, the vibration response investigation shall be carried out as specified in IEC 60068-2-6 [2]
(test Fc), with the following parameter severities:
Frequency range: 1 Hz to 35 Hz
Vibration amplitude: 2 m/s
Sweep rate:£ 1 octave/min
NOTE 1: The vibration amplitude may be reduced to 1 m/s or less in case of sharp resonances.
If a random test is used this shall be performed in accordance with the requirements of IEC 60068-2-64 [2], using the following
severities:
Frequency range: 1 Hz to 20 Hz 20 Hz to 35 Hz
2 3
ASD: 0,5 m /s -3 dB/octave
Duration: 3 minutes
2 3
NOTE 2: The Acceleration Spectral Density (ASD) value may be reduced to 0,3 m /s or less in case of sharp resonances.
The time-history stated in table 12 can be omitted if, after the vibration response investigation, the equipment does not exhibit
any resonance below 5 Hz and has passed the sinusoidal vibration test reported in table 9 (class 3.4) or in table 11 (class 3.5)
for class 3M5. This test is sufficient to prove compliance with earthquake conditions given in ETS 300 019-1-3 [1].
ETSI
24 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
4.2 Test conditioning
See table 12.
The extent to which the equipment under test has to function during tests or merely to survive conditions of test shall be stated in the product specification.
Table 12: Test specification T 3.1 to T 3.5: Earthquake test
Environmental parameter Environmental Environmental test specification T3.x:
class 3.x Earthquake test
Type Parameter Detail Characteristic Test severity Duration Reference Method Notes
parameter severity
Earthquake time-history RRS see part 1-3 fig.1, tab.13 IEC 60068-2-57 Ff: time-history 20
method
frequency range 0,3 - 50 1 - 35
(Hz)
ZPA (m/s )15 15
axes 3 30 s
damping ratio (%) 2
NOTE: n = number of note, see clause 5.
ETSI
25 ETSI EN 300 019-2-3 V2.1.2 (1999-09)
2 % damping
0,1 1 10 100
frequency [Hz]
Figure 1: Earthquake Required Response Spectrum
Table 13: Acceleration co-ordinates for the Required Response Spectrum in figure 1
Co-ordinate Frequency Values for upper floor
point [Hz] acceleration [m/s ]
11 30
22 50
35 50
415 15
535 15
5 Notes to tables
5.1 General note
The present document applies to the use of stationary equipment at weather protected locations covered by the environmental
conditions stated in ETS 300 019-1-3 [1].
The relevant test specification should specify when, during the environmental test programme, the equipment is in it's
operational state, and which performance requirements should be measured before, during and after the test, together with the
appropriate pass/fail criteria.
5.2 Notes to tables 1 to 12
NOTE 1: (Air temperature, low)
The characteristic severity can be used as a cold start up temperature, but it may be modified by the product specification. The
equipment under test shall remain operational throughout this test, except for the cold start up test which shall commence once
low temperature stability is achieved.