SIST HD 457 S1:2003
(Main)Code for designation of colours
Code for designation of colours
Applies to the text of descriptions, drawings, markings, etc., in the electrotechnical field and lays down a letter code for the designation of some distinct colour. Has the status of a basic safety publication in accordance with IEC Guide 104.
Code zur Farbkennzeichnung
Code de désignation de couleurs
S'applique aux textes de descriptions, schémas, marquages, etc., utilisés en électrotechnique et établit un code littéral pour la désignation de quelques couleurs distinctes. A le statut d'une publication fondamentale de sécurité conformément au Guide 104.
Code for designation of colours
General Information
Relations
Standards Content (Sample)
SLOVENSKI SIST HD 457 S1:2003
STANDARD
april 2003
Code for designation of colours
ICS 01.070; 29.020 Referenčna številka
SIST HD 457 S1:2003(en)
© Standard je založil in
...
This May Also Interest You
Establishes general rules for assigning particular meanings to certain visual, acoustsic and tactile indications. Has the status of a basic safety publication in accordance with IEC Guide 104.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard – translation35 pagesSlovenian languagesale 10% offe-Library read for×1 day
This International Standard specifies letter codes for designation of colours and provides rules for their combination to designate colour combinations. The letter codes are intended to be applied in the technical documentation of industrial installations, equipment and products, and in markings of equipment and products.
This basic safety publication is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51.
It is not intended for use by manufacturers or certification bodies. One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications. The requirements of this basic safety publication will not apply unless specifically referred to or included in the relevant publications.
This International Standard does not specify any requirements for the encoding of colour properties, nor for their visual representation. Such requirements are under the responsibility of the different technical committees.
- Standard10 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft7 pagesEnglish languagesale 10% offe-Library read for×1 day
Establishes general rules for assigning particular meanings to certain visual, acoustsic and tactile indications. Has the status of a basic safety publication in accordance with IEC Guide 104.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard – translation35 pagesSlovenian languagesale 10% offe-Library read for×1 day
This part of ISO 25178 specifies generic procedures for the calibration, adjustment and verification of
areal topography measuring instruments with planar rather than full 3D measurement behaviour and for
the determination of measurement uncertainty components associated with effects on the metrological
characteristics. It considers, what all areal instruments have in common, including. point sensing
instruments with lateral scanning devices. For instrument specific principles, other parts may be
developed in the 700 series of ISO standard 25178. In particular, the calibration of contacting systems
with additional arcuate motion is not covered by this standard and may be described in a future revision
of the ISO 25178-701.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft37 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the characteristics of hexagon socket button head screws with collar, with reduced loadability due to head design, in steel, with metric coarse pitch threads M3 to M16, and with product grade A.
If in certain cases other specifications are requested, dimensional options can be selected from ISO 888 or ISO 4753.
NOTE The reduced loadability (related to the head dimensions in combination with penetration of the hexagon socket specified in this document) implies a limitation of ultimate tensile load shown by a specific marking (property class preceded by a zero). The loadability in the head is assumed to be 80 % of that in the thread for all sizes and all property classes, see Table 4.
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the characteristics of hexagon socket button head screws with reduced loadability due to head design, in steel and stainless steel, with metric coarse pitch threads M3 to M16, and with product grade A.
If, in certain cases, other specifications are requested, stainless steel grades can be selected from ISO 3506-1, and the dimensional options from ISO 888 or ISO 4753.
NOTE The reduced loadability (related to the head dimensions in combination with penetration of the hexagon socket specified in this document) implies a limitation of ultimate tensile load shown by a specific marking (property class preceded by a zero). The loadability in the head is assumed to be 80 % of that in the thread for all sizes and all property classes, see Table 4.
- Standard17 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the characteristics of reference measurement standards of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This document relates to alpha-emitters, beta-emitters, and photon emitters of maximum photon energy not greater than 1,5 MeV.
It does not describe the procedures involved in the use of these reference measurement standards for the calibration of surface contamination monitors. Such procedures are specified in IEC 60325[6], IEC 62363[7], and other documents.
NOTE Since some of the proposed photon standards include filters, the photon standards are to be regarded as reference measurement standards of photons of a particular energy range and not as reference measurement standards of a particular radionuclide. For example, a 241Am source with the recommended filtration does not emit from the surface the alpha particles or characteristic low-energy L X-ray photons associated with the decay of the nuclide. It is designed to be a reference measurement standard that emits photons with an average energy of approximately 60 keV.
This document also specifies preferred reference radiations for the calibration of surface contamination monitors. These reference radiations are realized in the form of adequately characterized large area sources specified, without exception, in terms of surface emission rate and activity which are traceable to national standards.
- Standard21 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft18 pagesEnglish languagesale 10% offe-Library read for×1 day
The purpose of this document is to provide minimum criteria required for quality assurance and quality control, evaluation of the performance and to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories applying ex vivo X-band EPR spectroscopy with human tooth enamel.
This document covers the determination of absorbed dose in tooth enamel (hydroxyapatite). It does not cover the calculation of dose to organs or to the body.
This document addresses:
a) responsibilities of the customer and laboratory;
b) confidentiality and ethical considerations;
c) laboratory safety requirements;
d) the measurement apparatus;
e) preparation of samples;
f) measurement of samples and EPR signal evaluation;
g) calibration of EPR dose response;
h) dose uncertainty and performance test;
i) quality assurance and control.
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft28 pagesEnglish languagesale 10% offe-Library read for×1 day
This document focuses on monitoring the activity concentrations of radioactive gases. They allow the calculation of the activity releases, in the gaseous effluent discharge from facilities producing positron emitting radionuclides and radiopharmaceuticals. Such facilities produce short-lived radionuclides used for medical purposes or research and can release gases typically including, but not limited to 18F, 11C, 15O and 13N. These facilities include accelerators, radiopharmacies, hospitals and universities. This document provides performance‑based criteria for the design and use of air monitoring equipment including probes, transport lines, sample monitoring instruments, and gas flow measuring methods. This document also provides information on monitoring program objectives, quality assurance, development of air monitoring control action levels, system optimisation and system performance verification.
The goal of achieving an unbiased measurement is accomplished either by direct (in-line) measurement on the exhaust stream or with samples extracted from the exhaust stream (bypass), provided that the radioactive gases are well mixed in the airstream. This document sets forth performance criteria and recommendations to assist in obtaining valid measurements.
NOTE 1 The criteria and recommendations of this document are aimed at monitoring which is conducted for regulatory compliance and system control. If existing air monitoring systems were not designed according to the performance criteria and recommendations of this document, an evaluation of the performance of the system is advised. If deficiencies are discovered based on a performance evaluation, a determination of the need for a system retrofit is to be made and corrective actions adopted where practicable.
NOTE 2 The criteria and recommendations of this document apply under both normal and off‑normal operating conditions, provided that these conditions do not include production of aerosols or vapours. If the normal and/or off-normal conditions produce aerosols and vapours, then the aerosol collection principles of ISO 2889 also apply.
- Standard62 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft59 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the characteristics of hexalobular socket countersunk flat head screws with reduced loadability due to head design, in steel and stainless steel, with metric coarse pitch threads M2 to M10, and with product grade A.
If in certain cases other specifications are requested, stainless steel grades can be selected from ISO 3506‑1, and dimensional options from ISO 888 or ISO 4753.
NOTE 1 The reduced loadability (related to the countersunk head dimensions in combination with penetration of the hexalobular socket specified in this document) implies a limitation of ultimate tensile load shown by a specific marking (property class preceded by a zero). The loadability in the head is assumed to be 80 % of that in the thread for all sizes and all property classes; see Table 3.
NOTE 2 Hexalobular socket countersunk head screws (high head), with full loadability are specified in ISO 14582, but these products are not interchangeable, because of different head heights.
NOTE 3 Particular attention is needed to ensure alignment of the countersunk head with the bearing surface of the countersink in the assembly.
- Standard19 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft15 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.