Residential solid fuel burning appliances - Part 2-7: Combination appliances fired by wood logs and pellets

This document is applicable to space heaters, inset appliances and cookers intended for mechanical fuelling with wood pellets and for manual fuelling with other solid fuel. They can be freestanding or inset appliances.
The intended use of the appliances is space heating in residential buildings and can be cooking. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances typically use auxiliary energy which is measured in this standard as well. They are operated with natural draught and can be fan-assisted.
NOTE 1   A fan-assisted appliance does still operate under negative pressure in the flue gas system.
For inset appliances and especially their testing additional information can be necessary from EN 16510-2-2.
These appliances burn wood pellets and wood logs only, in accordance with the appliance instructions. They only operate with the firedoors closed.
NOTE 2   These appliances can have an integral fuel hopper or be combined with an external fuel hopper.
These appliances can be fitted with a single or double combustion chamber having a single flue gas outlet.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of combination appliances fired by wood logs and pellets.
This document is not applicable to appliances
-   with boiler intended for water systems having water temperatures above 110°C and 3 bar and for sanitary hot water,
-   intended to be used with a pure horizontal exhaust (through the building wall),
-   with flue gas condensation in the appliance,
-   switching on / off for part load operation,
-   with simultaneous wood and pellet operation with a single flue gas outlet,
-   with non-automatic pellet loading,
-   with single combustion chamber and double flue gas outlet.

Häusliche Feuerstätten für feste Brennstoffe - Teil 2-7: Kombinationsfeuerstätten für Scheitholz und Pellets

Dieses Dokument ist anwendbar Raumheizer, Einsätze und Herde, die mechanisch mit Holzpellets oder manuell mit anderen festen Brennstoffen beschickt werden. Dies können freistehende oder eingebaute Geräte sein.
Der Verwendungszweck der Geräte ist Raumheizung in Wohngebäuden und kann das Kochen sein. Sie können mit wasserführenden Bauteilen (als feste Bestandteile des Gerätes mit zu erhitzendem Wasser) zur Warmwasserbereitung der Zentralheizung ausgestattet sein.
Diese Geräte verwenden typischerweise Hilfsenergie, die ebenfalls in diesem Dokument bestimmt wird. Sie werden mit natürlichem Förderdruck betrieben und können Gebläse unterstützt sein.
ANMERKUNG 1   Eine gebläseunterstützte Feuerstätte arbeitet bei Unterdruck im Abgassystem.
Für Einsätze und insbesondere deren Prüfung können zusätzliche Informationen aus EN 16510-2-2 relevant sein.
Diese Geräte verfeuern nur Holzpellets und Scheitholz, in Übereinstimmung mit der Geräteanleitung. Sie werden nur mit geschlossenen Feuerraumtüren betrieben.
ANMERKUNG 2   Diese Geräte können einen integrierten Brennstoffbehälter haben oder mit einem externen Brennstoffbehälter kombiniert werden.
Diese Geräte können mit einer einfachen oder einer doppelten Brennkammer mit einfachem Abgasabzug ausgestattet sein
Dieses Dokument legt das Verfahren für die Bewertung und Überprüfung der Leistungsbeständigkeit (AVCP) der Eigenschaften von mit Holz und Holzpellets beschickte Kombinationsgeräten fest.
Dieses Dokument ist nicht anzuwenden für Geräte:
-   mit wasserführenden Bauteilen vorgesehen für Wassersysteme mit einer Wassertemperatur über 110 °C und 3 bar und Brauchwarmwasser;
-   die für den Betrieb mit direkter horizontaler Abgasführung (durch die Gebäudewand) vorgesehen sind;
-   mit Abgaskondensation in der Feuerstätte;
-   mit an- und ausschaltendem Teillast-Betrieb;
-   mit gleichzeitigem Betrieb von Holz und Pellets mit einem einfachen Abgasabzug;
-   mit nicht automatischer Zuführung von Pellets;
-   mit einfacher Brennkammer und doppeltem Abgasabzug.

Appareils de chauffage domestiques à combustible solide - Partie 2-7 : Appareils mixtes à bûches et à granulés de bois

Le présent document s’applique aux dispositifs de chauffage, inserts et cuisinières destinés au chauffage des locaux, à alimentation mécanique pour les granulés de bois et à alimentation manuelle pour tout autre combustible solide. Ces appareils peuvent être indépendants ou de type insert.
L’usage prévu des appareils est le chauffage des locaux dans les bâtiments résidentiels et éventuellement la cuisson. Ils peuvent être équipés d’un bouilleur (faisant partie intégrante de l’appareil et contenant de l’eau à chauffer) pour fournir de l’eau chaude aux systèmes de chauffage central.
Ces appareils utilisent généralement de l’énergie auxiliaire, qui est également mesurée dans la présente norme. Ils fonctionnent en tirage naturel et peuvent être équipés d’un ventilateur.
NOTE 1   Un appareil équipé d’un ventilateur fonctionne toujours avec un conduit de fumées soumis à une pression négative.
Pour les inserts et notamment leurs essais, des informations supplémentaires de l’EN 16510-2-2 peuvent être nécessaires.
Ces appareils utilisent uniquement des bûches de bois et des granulés de bois, conformément aux instructions de l’appareil. Ils ne fonctionnent qu’avec les portes foyères fermées.
NOTE 2   Ces appareils peuvent comporter une trémie à combustible intégrée ou être combinés avec une trémie à combustible externe.
Ces appareils peuvent être équipés d’une chambre de combustion simple ou double, à une seule buse d’évacuation.
Le présent document spécifie des modes opératoires pour l’évaluation et la vérification de la constance des performances (EVCP) des caractéristiques des appareils mixtes à bûches et à granulés de bois.
Le présent document ne s’applique pas aux appareils :
-   à bouilleur prévu pour les circuits d’eau dont la température d’eau est supérieure à 110 °C et 3 bar ainsi que pour l’eau chaude sanitaire ;
-   prévus pour une utilisation avec une évacuation purement horizontale (directement à travers le mur du bâtiment) ;
-   à condensation des fumées dans l’appareil ;
-   à commutation marche/arrêt pour un fonctionnement à charge partielle ;
-   fonctionnant simultanément avec du bois et des granulés avec une seule buse d’évacuation ;
-   dont le chargement des granulés n’est pas automatique ;
-   à une seule chambre de combustion et une buse d’évacuation double.

Grelne naprave na trdna goriva za stanovanjske stavbe - 2-7. del: Kombinirane naprave na lesna polena in pelete

General Information

Status
Not Published
Public Enquiry End Date
31-Jul-2023
Technical Committee
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
25-May-2023
Due Date
12-Oct-2023
Completion Date
02-Aug-2023

Buy Standard

Draft
prEN 16510-2-7:2023
English language
41 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 16510-2-7:2023
01-julij-2023
Grelne naprave na trdna goriva za stanovanjske stavbe - 2-7. del: Kombinirane
naprave na lesna polena in pelete
Residential solid fuel burning appliances - Part 2-7: Combination appliances fired by
wood logs and pellets
Häusliche Feuerstätten für feste Brennstoffe - Teil 2-7: Kombinationsfeuerstätten für
Scheitholz und Pellets
Appareils de chauffage domestiques à combustible solide - Partie 2-7 : Appareils mixtes
à bûches et à granulés de bois
Ta slovenski standard je istoveten z: prEN 16510-2-7
ICS:
97.100.30 Grelniki na trdo gorivo Solid fuel heaters
oSIST prEN 16510-2-7:2023 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 16510-2-7:2023

---------------------- Page: 2 ----------------------
oSIST prEN 16510-2-7:2023


DRAFT
EUROPEAN STANDARD
prEN 16510-2-7
NORME EUROPÉENNE

EUROPÄISCHE NORM

May 2023
ICS 97.100.30
English Version

Residential solid fuel burning appliances - Part 2-7:
Combination appliances fired by wood logs and pellets
 Häusliche Feuerstätten für feste Brennstoffe - Teil 2-7:
Kombinationsfeuerstätten für Scheitholz und Pellets
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 295.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2023 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 16510-2-7:2023 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 16510-2-7:2023
prEN 16510-2-7:2023 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Characteristics . 6
4.1 Load bearing capacity . 6
4.2 Protection of combustible materials . 6
4.3 Carbon monoxide emission (CO) . 7
4.4 Nitrogen oxides (NO ) emissions . 8
x
4.5 Emission of organic gaseous compounds (OGC) emissions . 8
4.6 Particulate matter (PM) emissions . 9
4.7 Safety and accessibility in use . 9
4.7.1 General . 9
4.7.2 Flue gas outlet temperature at nominal heat output . 9
4.7.3 Flue gas outlet temperature at part load heat output. 10
4.7.4 Minimum flue draught at nominal heat output . 10
4.7.5 Minimum flue draught at part load heat output . 10
4.7.6 Flue gas mass flow at nominal heat output . 10
4.7.7 Flue gas mass flow at part load heat output . 10
4.7.8 Fire safety of installation to the chimney . 10
4.8 Energy economy and heat retention . 11
4.8.1 General . 11
4.8.2 Space heat output at nominal heat output . 11
4.8.3 Water heat output, if existing at nominal heat output. 11
4.8.4 Efficiency at nominal heat output . 11
4.8.5 Space heat output at part load heat output . 11
4.8.6 Water heat output, if existing at part load heat output . 12
4.8.7 Efficiency at part load heat output . 12
4.8.8 Seasonal space heating efficiency at appliance’s nominal heat output . 12
4.8.9 Energy efficiency . 12
4.8.10 Electric power consumption at nominal heat output, if existing . 13
4.8.11 Electric power consumption at part load heat output, if existing . 13
4.8.12 Standby mode power consumption, if existing . 13
4.9 Environmental sustainability . 13
5 Descriptive features . 15
5.1 Data for potential use with room ventilation systems: type of appliance (in relation
to its tightness to the room) . 15
5.2 Data for the building's statics: appliance's mass . 15
5.3 Materials and construction elements . 15
5.3.1 General . 15
5.3.2 General stresses . 15
5.3.3 Integral boiler or heat exchanger . 15
5.4 Risk of burning fuel falling out . 15
5.5 Temperature rise in the fuel storage . 16
5.5.1 Temperature rise in the fuel hopper . 16
2

---------------------- Page: 4 ----------------------
oSIST prEN 16510-2-7:2023
prEN 16510-2-7:2023 (E)
5.5.2 Safety against back burning through the fuel conveyor system . 16
5.6 Temperature rise of the operating components . 16
5.7 Spillage of flue gases into the room. 16
5.7.1 Possible spillage of CO, if relevant for the fuel type . 16
5.7.2 Safety test for spillage of combustion gas and discharge of embers . 16
5.7.3 Open operation . 16
5.8 Cleanability . 16
5.8.1 Heating surfaces . 16
5.8.2 Flueways . 17
5.8.3 Ashpan . 17
5.8.4 Bottomgrate . 17
5.8.5 Damper . 17
5.8.6 Fan-cut-out-device . 17
5.9 Strength and leak tightness of boiler shells . 17
6 Assessment and verification of constancy of performance - AVCP . 18
6.1 General . 18
6.2 Assessment of performance . 18
6.2.1 General . 18
6.2.2 Test samples, testing and compliance criteria . 19
6.3 Verification of constancy of performance . 20
6.3.1 Factory production control (FPC) . 20
Annex A (normative) Test methods . 25
Annex GA (normative) Measurement positions for conveyor systems . 33
Annex ZA (informative) Relationship of this European Standard with Regulation (EU) No.
305/2011 . 37
3

---------------------- Page: 5 ----------------------
oSIST prEN 16510-2-7:2023
prEN 16510-2-7:2023 (E)
European foreword
This document (prEN 16510-2-7:2023) has been prepared by Technical Committee CEN/TC 295
“Residential solid fuel burning appliances”, the secretariat of which is held by BSI.
This document has been prepared under a standardization request given to CEN by the European
Commission and the European Free Trade Association.
For relationship with (EU) Regulation 305/2011, see informative Annex ZA, which is an integral part of
this document.
The structure of EN 16510, Residential solid fuel burning appliances, is as follows:
— Part 1: General requirements and test methods;
— Part 2-1: Roomheaters;
— Part 2-2: Inset appliances including open fires;
— Part 2-3: Cookers;
— Part 2-4: Independent boilers — Nominal heat output up to 50 kW;
— Part 2-5: Slow heat release appliances;
— Part 2-6: Mechanically by wood pellets fed roomheaters, inset appliances and cookers;
— Part 2-7: Combination appliances fired by wood logs and pellets.
Other sections of Part 2 will be added to cover residential solid fuel burning appliances not included in
parts 2-1 to 2-7.
Subclauses and Figures which are additional to those in FprEN 16510-1:2022 are numbered starting with
701. Annexes which are additional to those in FprEN 16510-1:2022 are numbered starting with GA.
For inset pellet/wood appliances and especially their testing, additional information from
FprEN 16510-2-2:2022 is relevant.
For pellet appliances and especially their testing, additional information from FprEN 16510-2-6:2022 is
relevant.
For cookers and especially their testing, additional information from FprEN 16510-2-3:2022 is relevant.
For appliances according to this document the same additional information regarding instructions as
specified in EN 16510-1:2022, Clause 7 for appliances according to EN 16510-2-6:2022 is applicable.
Descriptive features according to EN 16510-1, 4.4 for devices according to EN 16510-2-6 are equally
valid for devices according to this document.
4

---------------------- Page: 6 ----------------------
oSIST prEN 16510-2-7:2023
prEN 16510-2-7:2023 (E)
1 Scope
This document is applicable to space heaters, inset appliances and cookers intended for mechanical
fuelling with wood pellets and for manual fuelling with other solid fuel. They can be freestanding or inset
appliances.
The intended use of the appliances is space heating in residential buildings and can be cooking. They can
be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of
hot water for central heating systems.
These appliances typically use auxiliary energy which is measured in this standard as well. They are
operated with natural draught and can be fan-assisted.
NOTE 1 A fan-assisted appliance does still operate under negative pressure in the flue gas system.
For inset appliances and especially their testing additional information can be necessary from
EN 16510-2-2.
These appliances burn wood pellets and wood logs only, in accordance with the appliance instructions.
They only operate with the firedoors closed.
NOTE 2 These appliances can have an integral fuel hopper or be combined with an external fuel hopper.
These appliances can be fitted with a single or double combustion chamber having a single flue gas outlet.
This document specifies procedures for assessment and verification of constancy of performance (AVCP)
of characteristics of combination appliances fired by wood logs and pellets.
This document is not applicable to appliances
— with boiler intended for water systems having water temperatures above 110°C and 3 bar and for
sanitary hot water,
— intended to be used with a pure horizontal exhaust (through the building wall),
— with flue gas condensation in the appliance,
— switching on / off for part load operation,
— with simultaneous wood and pellet operation with a single flue gas outlet,
— with non-automatic pellet loading,
— with single combustion chamber and double flue gas outlet.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document.
EN 15456:2008, Heating boilers — Electrical power consumption for heat generators — System boundaries
— Measurements
EN 15804:2012+A2:2019, Sustainability of construction works — Environmental product declarations —
Core rules for the product category of construction products
EN 16510-1:2022, Residential solid fuel burning appliances — Part 1: General requirements and test
methods
5

---------------------- Page: 7 ----------------------
oSIST prEN 16510-2-7:2023
prEN 16510-2-7:2023 (E)
EN 16510-2-2:2022, Residential solid fuel burning appliances — Part 2-2: Inset appliances including open
fires
EN 16510-2-3:2022, Residential solid fuel burning appliances — Part 2-3: Cookers
EN 16510-2-4:2022, Residential solid fuel burning appliances — Part 2-4: Independent boilers — Nominal
heat output up to 50 kW
EN 16510-2-6:2022, Residential solid fuel burning appliances — Part 2-6: Mechanically by wood pellets fed
roomheaters, inset appliances and cookers
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 16510-1:2022,
EN 16510-2-2:2022, EN 16510-2-3:2022, EN 16510-2-6:2022 apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
4 Characteristics
4.1 Load bearing capacity
The performance of the appliance in relation to the ability to carry a chimney shall be determined in
accordance with EN 16510-1:2022, 4.6.
If for an appliance with an upper outlet the ability to carry a chimney is specified the value of the
maximum load is to be given in [kg] as an integer according to EN 16510-1:2022, Table 22, no. 57 (m ).
chim
4.2 Protection of combustible materials
The performance of the appliance in relation to protection of combustible materials shall be determined
in accordance with EN 16510-1:2022, 5.6.
When tested in accordance with EN 16510-1:2022, 5.6, the protection measure(s) as specified according
to Table 1 shall be given as minimum distance to combustibles and if appropriate as material type and
thickness of protective insulation material.
The protection measures as specified shall be given in [mm] as an integer according to EN 16510-1:2022,
Table 22, no. 33, 34, 35, 36, 37, 38, 39 and 41 (d , d , d , d , d , d , d , s).
R S C p F L B
6

---------------------- Page: 8 ----------------------
oSIST prEN 16510-2-7:2023
prEN 16510-2-7:2023 (E)
Table 1 — Protection of combustible materials
Protection measure Declared clearance distance to Protective
combustible material or thickness insulation material
of protective insulation material if any

[mm]
Minimum distance to

combustibles - bottom (d )
B
Minimum distance to
combustibles – floor in front –
(d )
F
Minimum distance to

combustibles – ceiling (d )
C
Minimum distance to

combustibles – rear (d )
R
Minimum distance to

combustibles – side (d )
S
Minimum distance to
combustibles – side –
radiation area (d )
L
Minimum distance to
adjacent combustible –
materials (e.g. furniture) (d )
P
Protective insulation

material (s)
4.3 Carbon monoxide emission (CO)
The performance of the appliance in relation to carbon monoxide emission at nominal heat output and at
part load heat output (if part load is specified) shall be determined in accordance with
FprEN 16510-1:2022, 6.3.1 and 6.3.2.
The CO value if specified at nominal heat output and at part load heat output (if part load is specified) is
3
to be given in [mg/m ] as an integer according to FprEN 16510-1:2022, Table 22, no. 17 (CO
nom
(13 % O )).
2
When tested in accordance with FprEN 16510-1:2022, 6.3.2 the CO emission at nominal heat output shall
not exceed the threshold levels as given in Table 2.
7

---------------------- Page: 9 ----------------------
oSIST prEN 16510-2-7:2023
prEN 16510-2-7:2023 (E)
Table 2 — Threshold levels for CO emission
Appliance type Threshold level at 13 % O
2
3
open fronted solid fuel local space heaters 2000 mg/m
closed fronted solid fuel local space heaters using
3
solid fuel other than compressed wood in the form 1500 mg/m
of pellets including cookers
closed fronted solid fuel local space heaters using
3

compressed wood in form of pellets including 300 mg/m
cookers
Each test shall be performed for both fuels (wood logs and compressed woods in form of pellets).
4.4 Nitrogen oxides (NO ) emissions
x
The performance of the appliance in relation to nitrogen oxides emissions at nominal heat output and at
part load heat output (if part load is specified) shall be determined in accordance with EN 16510-1:2022,
6.3.1 and 6.3.3.
The NO value if specified at nominal heat output and at part load heat output (if part load is specified) is
x
3
to be given in [mg/m ] as an integer according to EN 16510-1:2022, Table 22, no. 20 (NO (13 % O )).
xnom 2
When tested in accordance with EN 16510-1:2022, 6.3.3 the NO emission at nominal heat output shall
x
not exceed the threshold levels as given in Table 3.
Table 3 — Threshold levels for NOx emission (expressed as NO )
2
Appliance type Threshold level at 13 % O
2
3
open fronted solid fuel local space heaters, closed 200 mg/m
fronted solid fuel local space heaters and cookers
using biomass
3
open fronted solid fuel local space heaters, closed 300 mg/m
fronted solid fuel local space heaters and cookers
using fossil solid fuel
Each test shall be performed for both fuels (wood logs and compressed woods in form of pellets).
4.5 Emission of organic gaseous compounds (OGC) emissions
The performance of the appliance in relation to organic gaseous compounds emission at nominal heat
output and at part load heat output (if part load is specified) shall be determined in accordance with
EN 16510-1:2022, 6.3.1 and 6.3.4.
The OGC value if specified at nominal heat output and at part load heat output (if part load is specified)
3
is to be given in [mg/m ] as an integer according to EN 16510-1:2022, Table 22, no. 23 (OGC
nom
(13 % O )).
2
When tested in accordance with EN 16510-1:2022, 6.3.4 the OGC emission at nominal heat output shall
not exceed the threshold levels as given in Table 4.
8

---------------------- Page: 10 ----------------------
oSIST prEN 16510-2-7:2023
prEN 16510-2-7:2023 (E)
Table 4 — Threshold levels for OGC emission (expressed as C)
Appliance type Threshold Level at 13 % O
2
3
open fronted solid fuel local space heaters 120 mg C/m
closed fronted solid fuel local space heaters using
3
solid fuel other than compressed wood in the form 120 mg C/m
of pellets including cookers
closed fronted solid fuel local space heaters using
3

compressed wood in form of pellets including 60 mg C/m
cookers
Each test shall be performed for both fuels (wood logs and compressed woods in form of pellets).
4.6 Particulate matter (PM) emissions
The performance of the appliance in relation to particulate matter emission at nominal heat output and
at part load heat output (if part load is specified) shall be determined in accordance with
EN 16510-1:2022, 6.3.1 and 6.3.5.
The particulate matter value if specified at nominal heat output and at part load heat output (if part load
3
is specified) is to be given in [mg/m ] as an integer according to EN 16510-1:2022, Table 22, no. 26
(PM (13 % O )).
nom 2
When tested in accordance with EN 16510-1:2022, 6.3.5 the particulate matter (PM) emissions at
nominal heat output shall not exceed the threshold levels as given in Table 5.
Table 5 — Threshold levels for PM emission
Appliance type Threshold Level at 13 % O
2
3
open fronted solid fuel local space heaters 50 mg/m
closed fronted solid fuel local space heaters using
3
solid fuel other than compressed wood in the form 40 mg/m
of pellets and cookers
closed fronted solid fuel local space heaters using
3
20 mg/m
compressed wood in form of pellets
Each test shall be performed for both fuels (wood logs and compressed woods in form of pellets).
4.7 Safety and accessibility in use
4.7.1 General
The data for the installation to a chimney are to be evaluated at nominal heat output. Specific data are to
be evaluated at safety test heat output. Additional data are to be evaluated at part load heat output, if part
load is specified.
Each test shall be performed for both fuels (wood logs and compressed woods in form of pellets).
4.7.2 Flue gas outlet temperature at nominal heat output
The performance of the appliance in relation to flue gas outlet temperature at nominal heat output shall
be determined in accordance with EN 16510-1:2022, 6.2.1.
The value of the flue gas outlet temperature if specified for the installation of the appliance to a chimney
is to be given in [°C] as an integer according to EN 16510-1:2022, Table 22, no. 47 (T ).
snom
9

---------------------- Page: 11 ----------------------
oSIST prEN 16510-2-7:2023
prEN 16510-2-7:2023 (E)
4.7.3 Flue gas outlet temperature at part load heat output
The performance of the appliance in relation to flue gas outlet temperature at part load heat output (if
part load is specified) shall be determined in accordance with EN 16510-1:2022, 6.2.1.
The value of the flue gas outlet temperature at part load heat output (if part load is specified) for the
installation of the appliance to a chimney if specified is to be given in [°C] as an integer according to
EN 16510-1:2022, Table 22, no. 48 (T ).
spart
4.7.4 Minimum flue draught at nominal heat output
The performance of the appliance in relation to the minimum flue draught at nominal heat output shall
be determined in accordance with EN 16510-1:2022, 6.5.
The value of the minimum flue draught if specified at nominal heat output for the installation of the
appliance to a chimney is to be given in [Pa] as an integer according to EN 16510-1:2022, Table 22, no.
29 (p ).
nom
Appliances with a nominal heat output less than or equal to 25 kW shall be tested at a flue draught of
(12 ± 2) Pa or at the flue draught specified for the nominal heat output test. The temperature safety test
shall be carried out at the same draught.
Appliances having a nominal heat output greater than 25 kW shall be tested during the nominal heat
output test at such flue draught specified in the appliance instructions.
4.7.5 Minimum flue draught at part load heat output
The performance of the appliance in relation to the minimum flue draught at part load heat output (if part
load is specified) shall be determined in accordance with EN 16510-1:2022, 6.5.
The minimum value of the flue draught if specified at part load heat output (if part load is specified) for
the installation of the appliance to a chimney is to be given in [Pa] as an integer according to
EN 16510-1:2022, Table 22, no. 30 (p ).
part
For the partial load test all appliances shall be tested either at a flue draught of (10 ± 2) Pa or at the flue
draught specified for the part load heat output test.
4.7.6 Flue gas mass flow at nominal heat output
The performance of the appliance in relation to the flue gas mass flow at nominal heat output shall be
determined in accordance with EN 16510-1:2022, 6.12.
The flue gas mass flow value if specified at nominal heat output for the installation of the appliance to a
chimney is to be given in [g/s] with 1 decimal according to EN 16510-1:2022, Table 22, no. 50 (ϕ ).
f,g nom
4.7.7 Flue gas mass flow at part load heat output
The performance of the appliance in relation to the flue gas mass flow at part load heat output (if part
load is specified) shall be determined in accordance with EN 16510-1:2022, 6.12.
The flue gas mass flow value if specified at part load heat output (if part load is specified) for the
installation of the appliance to a chimney is to be given in [g/s] with 1 decimal according to
EN 16510-1:2022, Table 22, no. 51 (ϕ ).
f,g pa
...