SIST EN 300 220-1 V1.3.1:2005
(Main)ElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 1: Technical characteristics and test methods
ElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 1: Technical characteristics and test methods
EN 300 220-1 covers a wide range of telecommunication, telemetry and generic non-speech applications, such as alarm systems, identification, detection, remote control etc., in the frequency band 25 - 1000 MHz with power levels up to 500 mW. The work programme is requested to take into account the comments received at the Vote stage of the EN 300 220-1 which were considered as Technical comments rather then Editorial and therefore could not be considered. In addition comments have been received on the definition of the Duty Cycle and clarification may be necessary. Similarly, for wideband equipment (subclause 8.6) an investigation has been requested into the suitability of the stated value for maximum frequency error, currently defined as shall not exceed 10% of the assigned band or wideband channel. Based on the completion of the above investigations, if necessary, an amendment to the published EN 300 220-1 will be prepared for approval for publication.
Elektromagnetna združljivost in zadeve v zvezi z radijskim spektrom (ERM) - Naprave kratkega dosega (SRDs) - Radijska oprema za uporabo v frekvenčnem območju od 25 MHz do 1000 MHz z močmi do 500 mW - 1. del: Tehnične karakteristike in preskuševalne metode
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 300 220-1 V1.3.1:2005
01-julij-2005
(OHNWURPDJQHWQD]GUXåOMLYRVWLQ]DGHYHY]YH]L]UDGLMVNLPVSHNWURP(50
1DSUDYHNUDWNHJDGRVHJD65'V5DGLMVNDRSUHPD]DXSRUDERYIUHNYHQþQHP
REPRþMXRG0+]GR0+]]PRþPLGRP:GHO7HKQLþQH
NDUDNWHULVWLNHLQSUHVNXãHYDOQHPHWRGH
ElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short Range Devices
(SRD); Radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with
power levels ranging up to 500 mW; Part 1: Technical characteristics and test methods
Ta slovenski standard je istoveten z: EN 300 220-1 Version 1.3.1
ICS:
33.060.20 Sprejemna in oddajna Receiving and transmitting
oprema equipment
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
SIST EN 300 220-1 V1.3.1:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 300 220-1 V1.3.1:2005
---------------------- Page: 2 ----------------------
SIST EN 300 220-1 V1.3.1:2005
ETSI EN 300 220-1 V1.3.1 (2000-09)
European Standard (Telecommunications series)
Electromagnetic compatibility and
Radio spectrum Matters (ERM);
Short Range Devices (SRD);
Radio equipment to be used in the 25 MHz to 1 000 MHz
frequency range with power levels ranging up to 500 mW;
Part 1: Technical characteristics and test methods
---------------------- Page: 3 ----------------------
SIST EN 300 220-1 V1.3.1:2005
2 ETSI EN 300 220-1 V1.3.1 (2000-09)
Reference
REN/ERM-RP08-0403-1
Keywords
radio, testing, SRD
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.:+33492944200 Fax:+33 493654716
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at http://www.etsi.org/tb/status/
If you find errors in the present document, send your comment to:
editor@etsi.fr
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2000.
All rights reserved.
ETSI
---------------------- Page: 4 ----------------------
SIST EN 300 220-1 V1.3.1:2005
3 ETSI EN 300 220-1 V1.3.1 (2000-09)
Contents
Intellectual Property Rights.7
Foreword.7
1 Scope .8
2 References .9
3 Definitions, symbols and abbreviations .10
3.1 Definitions.10
3.2 Symbols.10
3.3 Abbreviations .11
4 Technical requirement specifications.11
4.1 General requirements .11
4.1.1 Receiver classification .11
4.1.2 General performance criteria .12
4.2 Presentation of equipment for testing purposes.12
4.2.1 Choice of model for testing .12
4.2.2 Definitions of Switching Range (SR), alignment range and operational frequency range .12
4.2.2.1 Definition of SR .12
4.2.2.2 Definition of alignment range .12
4.2.2.3 Definition of operating frequency range .13
4.2.3 Definition of the categories of the alignment range (AR0, AR1, AR2 and AR3) .13
4.2.4 Testing of equipment of category AR0.13
4.2.5 Testing of equipment of category AR1.13
4.2.6 Testing of equipment of category AR2.13
4.2.7 Testing of equipment of category AR3.13
4.2.8 Testing of equipment capable of being aligned to operate with more than one frequency separation.14
4.2.9 Number of samples for testing.14
4.2.10 Testing of a family of equipment with a total operating range in excess of each equipment's
alignments range.15
4.2.11 Testing of equipment with alternative power levels .15
4.2.12 Testing of equipment that does not have an external 50 Ohm RF connector (integral antenna
equipment) .15
4.2.12.1 Equipment with an internal permanent or temporary antenna connector.15
4.2.12.2 Equipment with a temporary antenna connector.15
4.3 Mechanical and electrical design.16
4.3.1 General.16
4.3.2 Controls .16
4.3.3 Transmitter shut-off facility.16
4.3.4 Marking .16
4.3.4.1 Regulatory marking.16
4.3.4.2 Equipment identification, additional marking.16
4.3.5 Receiver mute or squelch.16
4.4 Declarations by the manufacturer.16
4.5 Auxiliary test equipment .16
4.6 Interpretation of the measurement results .17
5 Test conditions, power sources and ambient temperatures .17
5.1 Normal and extreme test conditions .17
5.2 Test power source.17
5.2.1 External test power source.17
5.2.2 Internal test power source .17
5.3 Normal test conditions.18
5.3.1 Normal temperature and humidity.18
5.3.2 Normal test power source .18
5.3.2.1 Mains voltage.18
5.3.2.2 Regulated lead-acid battery power sources .18
ETSI
---------------------- Page: 5 ----------------------
SIST EN 300 220-1 V1.3.1:2005
4 ETSI EN 300 220-1 V1.3.1 (2000-09)
5.3.2.3 Other power sources.18
5.4 Extreme test conditions .18
5.4.1 Extreme temperatures .18
5.4.1.1 Procedure for tests at extreme temperatures.18
5.4.1.1.1 Procedure for equipment designed for continuous operation .19
5.4.1.1.2 Procedure for equipment designed for intermittent operation .19
5.4.1.2 Extreme temperature ranges.19
5.4.2 Extreme test source voltages.19
5.4.2.1 Mains voltage.19
5.4.2.2 Regulated lead-acid battery power sources .20
5.4.2.3 Power sources using other types of batteries.20
5.4.2.4 Other power sources.20
6 General conditions.20
6.1 Normal test signals and test modulation.20
6.1.1 Normal test signals for analogue speech.20
6.1.2 Normal test signals for data .21
6.2 Artificial antenna.21
6.3 Test fixture .21
6.4 Test sites and general arrangements for radiated measurements .21
6.5 Modes of operation of the transmitter .22
6.6 Measuring receiver.22
7 Measurement uncertainty .22
8 Methods of measurement and limits for transmitter parameters .23
8.1 Frequency error .23
8.1.1 Definitions .23
8.1.1.1 Narrow band systems .23
8.1.1.2 Wide band systems.23
8.1.2 Narrow band .23
8.1.2.1 Method of measurement.23
8.1.3 Wide band.23
8.1.3.1 Method of measurement.24
8.1.4 Limits.24
8.2 Carrier power (conducted).24
8.2.1 Definition.24
8.2.2 Method of measurement .25
8.2.3 Limits.25
8.3 Effective radiated power .25
8.3.1 Definition.25
8.3.2 Methods of measurement.25
8.3.3 Limits.26
8.4 Response of the transmitter to modulation frequencies.27
8.4.1 Frequency deviation.27
8.4.1.1 Definition .27
8.4.1.2 Analogue signals within the audio bandwidth .27
8.4.1.2.1 Method of measurement .27
8.4.1.2.2 Limits .27
8.4.1.3 Analogue signals above the audio bandwidth .27
8.4.1.3.1 Method of measurement .27
8.4.1.3.2 Limits .28
8.4.2 Modulation depth.28
8.4.2.1 Definition .28
8.4.2.2 Analogue signals within the audio bandwidth .29
8.4.2.2.1 Method of measurement .29
8.4.2.2.2 Limits .29
8.4.2.3 Analogue signals above the audio bandwidth .29
8.4.2.3.1 Method of measurement .29
8.4.2.3.2 Limits .29
8.5 Adjacent channel power .30
8.5.1 Definition.30
8.5.2 Method of measurement .30
ETSI
---------------------- Page: 6 ----------------------
SIST EN 300 220-1 V1.3.1:2005
5 ETSI EN 300 220-1 V1.3.1 (2000-09)
8.5.2.1 Method of measurement using a power measuring receiver .30
8.5.3 Limits.31
8.6 Range of modulation bandwidth for wide band equipment (> 25 kHz) .31
8.6.1 Definition.31
8.6.2 Method of measurement .32
8.6.3 Limits.32
8.7 Spurious emissions.32
8.7.1 Definition.32
8.7.2 Method of measuring the power level in a specified load, subclause 8.7.1 a) i).33
8.7.3 Method of measuring the effective radiated power, subclause 8.7.1 a) ii).33
8.7.4 Method of measuring the effective radiated power, subclause 8.7.1 b).34
8.7.5 Limits.34
8.8 Frequency stability under low voltage conditions .34
8.8.1 Definition.34
8.8.2 Method of measurement .34
8.8.3 Limits.35
8.9 Duty Cycle.35
8.9.1 Definitions .35
8.9.2 Declaration.35
8.9.3 Duty cycle class .35
9 Receiver parameters .35
9.1 Adjacent channel selectivity - in band.35
9.1.1 Definition.35
9.1.2 Method of measurement .36
9.1.3 Limits.36
9.2 Adjacent band selectivity .36
9.2.1 Definition.36
9.2.2 Method of measurement .36
9.2.3 Limits.37
9.3 Blocking or desensitization .37
9.3.1 Definition.37
9.3.2 Method of measurement .37
9.3.3 Limits.37
9.4 Spurious radiation.38
9.4.1 Definition.38
9.4.2 Method of measuring the power level in a specified load, subclause 9.4.1 a) i).38
9.4.3 Method of measuring the effective radiated power, subclause 9.4.1 a) ii).38
9.4.4 Method of measuring the effective radiated power, subclause 9.4.1 b).39
9.4.5 Limits.39
Annex A (normative): Radiated measurement.40
A.1 Test sites and general arrangements for measurements involving the use of radiated fields.40
A.1.1 Anechoic Chamber.40
A.1.2 Anechoic Chamber with a conductive ground plane.41
A.1.3 Open Area Test Site (OATS) .42
A.1.4 Test antenna.43
A.1.5 Substitution antenna .43
A.1.6 Measuring antenna .44
A.1.7 Stripline arrangement .44
A.1.7.1 General.44
A.1.7.2 Description.44
A.1.7.3 Calibration .44
A.1.7.4 Mode of use .44
A.2 Guidance on the use of radiation test sites .44
A.2.1 Verification of the test site .45
A.2.2 Preparation of the EUT.45
A.2.3 Power supplies to the EUT.45
A.2.4 Volume control setting for analogue speech tests .45
A.2.5 Range length.45
A.2.6 Site preparation .46
ETSI
---------------------- Page: 7 ----------------------
SIST EN 30
...
Questions, Comments and Discussion