WC pans and WC suites with integral trap

This European Standard specifies constructional and performance requirements together with test methods for close-coupled suites, one-piece and independent WC pans with integral trap used for personal hygiene manufactured from glazed ceramics or stainless steel.
This European Standard does not apply to squatting toilets, WC pans without integral trap or flushing cisterns as separate appliances.
In the case of independent WC pans, the associated flushing cisterns and pressure valves are covered by other standards and the reference to cisterns in this standard is related only to the definition and requirements of flushing volume.
In the case of close-coupled suites and one-piece WCs, this standard also specifies design, performance requirements and the test methods for designated flushing cisterns with flushing mechanisms, inlet valves and overflows. For these products, this standard covers flushing cisterns designed to be connected to drinking water installations inside buildings.
Before installation of WCs, EN 12056-2 and national requirements need to be taken into consideration.

WC-Becken und WC-Anlagen mit angeformtem Geruchverschluss

Cuvettes de WC et cuvettes à réservoir attenant à siphon intégré

Straniščne školjke in straniščna oprema z integriranim sifonom

General Information

Status
Not Published
Public Enquiry End Date
27-Feb-2015
Current Stage
98 - Abandoned project (Adopted Project)
Start Date
10-Jul-2015
Due Date
15-Jul-2015
Completion Date
10-Jul-2015

Relations

Buy Standard

Draft
EN 997:2012/kFprA1:2015
English language
19 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 997:2012/kFprA1:2015
01-februar-2015
6WUDQLãþQHãNROMNHLQVWUDQLãþQDRSUHPD]LQWHJULUDQLPVLIRQRP
WC pans and WC suites with integral trap
WC-Becken und WC-Anlagen mit angeformtem Geruchverschluss
Cuvettes de WC et cuvettes à réservoir attenant à siphon intégré
Ta slovenski standard je istoveten z: EN 997:2012/FprA1
ICS:
91.140.70 Sanitarne naprave Sanitary installations
SIST EN 997:2012/kFprA1:2015 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 997:2012/kFprA1:2015

---------------------- Page: 2 ----------------------

SIST EN 997:2012/kFprA1:2015

EUROPEAN STANDARD
FINAL DRAFT
EN 997:2012
NORME EUROPÉENNE

EUROPÄISCHE NORM
FprA1
December 2014
ICS 91.140.70
English Version
WC pans and WC suites with integral trap
Cuvettes de WC et cuvettes à réservoir attenant à siphon WC-Becken und WC-Anlagen mit angeformtem
intégré Geruchverschluss
This draft amendment is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee
CEN/TC 163.

This draft amendment A1, if approved, will modify the European Standard EN 997:2012. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.

This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has
the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 997:2012/FprA1:2014 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 997:2012/kFprA1:2015
EN 997:2012/FprA1:2014 (E)
Contents Page
Foreword .3
1 Modification to Clause 3, Terms and definitions .4
2 Modification to 5.7.2.4.1, Test material .4
3 Addition of a new Clause 7, Dangerous substances .4
4 Modification to Clause 7, Marking.4
5 Modification to Clause 8, Evaluation of conformity .7
6 Modification to Annex ZA, Clause of this European Standard addressing the provisions of
the EU Construction Products Directive . 10

2

---------------------- Page: 4 ----------------------

SIST EN 997:2012/kFprA1:2015
EN 997:2012/FprA1:2014 (E)
Foreword
This document (EN 997:2012/FprA1:2014) has been prepared by Technical Committee CEN/TC 163 “Sanitary
appliances”, the secretariat of which is held by UNI.
This document is currently submitted to the Unique Acceptance Procedure.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of the EU Construction Products
Regulation.
For relationship with EU Construction Products Regulation, see informative Annex ZA, which is an integral
part of this document.
3

---------------------- Page: 5 ----------------------

SIST EN 997:2012/kFprA1:2015
EN 997:2012/FprA1:2014 (E)
1 Modification to Clause 3, Terms and definitions
At the end of the clause, add the following new term and definition:

3.40

product type
construction product with a set of representative performance levels or classes in
relation to its essential characteristics, produced using a given combination of raw
materials or other elements in a specific production process
”.
2 Modification to 5.7.2.4.1, Test material
Replace the paragraph in the subclause with the following one:
+15
“Single layer toilet paper with a saturation time of 15 s verified by the basket method in accordance with
−10
Annex D. Individual sheets shall have a size of (130 ± 10) mm x (100 ± 10) mm. The mass per unit surface of
2
the toilet paper shall be (30 ± 10) g/m .”.
3 Addition of a new Clause 7, Dangerous substances
Add the following new Clause 7 (and have the following clauses and subclauses accordingly renumbered):

7 Dangerous substances
National regulations on dangerous substances may require verification and declaration on release, and
sometimes content, when construction products covered by this standard are placed on those markets.
In the absence of European harmonized test methods, verification and declaration on release/content should
be done taking into account national provisions in the place of use.
NOTE An informative database covering European and national provisions on dangerous substances is available at
the Construction website on EUROPA accessed through: http://ec.europa.eu/enterprise/construction/cpd-ds/index.cfm.”.
4 Modification to Clause 7, Marking
Replace the former Clause 7 (now to be renumbered as Clause 8) with the following one:

8 Marking
The intended use of close-coupled suites, one-piece and independent WC pans with integral trap is personal
hygiene in accordance with the scope of this standard.
NOTE The intended use is also mentioned in Annex ZA, Tables ZA.1.1 and ZA.1.2. The abbreviation “PH” for the
intended use personal hygiene might be used for CE-marking.
A schematic drawing of the product may optionally follow the abbreviation for personal hygiene.
EXAMPLE 1 Use of full text:  Personal hygiene
4

---------------------- Page: 6 ----------------------

SIST EN 997:2012/kFprA1:2015
EN 997:2012/FprA1:2014 (E)
EXAMPLE 2 Use of abbreviation: PH
EXAMPLE 3 Use of the abbreviation and the optional schematic drawing: PH
Close-coupled suites, one-piece and independent WC pans with integral trap belong always to one class and
type at least. For each class and type a set of requirements to be tested (see 9.2.2) is defined. Due to this a
close-coupled suite, one-piece and independent WC pan with integral trap can be described with a
designation code which includes all fulfilled essential requirements.
The relevant product characteristics and the Essential Characteristics for close-coupled suites, one-piece and
independent WC pans with integral trap including their abbreviations are given in Tables 4 and 5.
Table 4 — Characteristics and abbreviations for class 1 products
Abbreviation Characteristics
EN 997 Number of European Standard for WCs and WC suites for product description
CL 1 - X Class 1 product with fixed flush volumes (9 l, 7 l, 6 l, 5 l or 4 l)
(Y) Minimum supply pressure (optionally)
A Flushing cistern
C Pressure flush valve
WL Water tightness / leak tightness
CF Capacity of flush
BP Backflow prevention (foul air)
CA Cleanability
VR(x) Valve reliability (Class 1 close-coupled suites and one-piece WC pans only – category I
or II)
LR Load resistance
DA Durability

Table 5 — Characteristics and abbreviations for class 2 products
Abbreviation Characteristics
EN 997 Number of European Standard for WCs and WC suites for product description
CL 2 - Z Class 2 product with flush volume ≤ 6 l and optionally minimum full flush volume (as Z)
WL Water tightness / leak tightness
CF Capacity of flush
BP Backflow prevention (foul air)
VR Valve reliability
CA Cleanability
LR Load resistance
DA Durability

All close-coupled suites, one-piece and independent WC pans with integral trap shall be designated in
accordance with the following system:
5

---------------------- Page: 7 ----------------------

SIST EN 997:2012/kFprA1:2015
EN 997:2012/FprA1:2014 (E)
Valve reliability (category I or II)
Flushing device and optionally minimum supply pressure
Minimum full flush volume, for class II optional
Flush volume for class I
Class of product
Number of standard
EN 997 — CL1 (or 2) — (X or Z) — A (or C) / Y— VR I (or II)
WL — CF — BP — CA — VR — LR — DA
Watertightness / leaktightness
Capacity of flush
Backflow prevention (of foul air)
Cleanability
Valve reliability
Load resistance
Durability
The declaration of the characteristics of the second line is considered being covered by the declaration of the
relevant class. However, the characteristics should be listed when one of those characteristics is not declared.
EXAMPLE 1 Class 1 independent WC pan for a flush volume of 5 l and 4 l when flushed by a flushing cistern, and for
a flush volume of 6 l when flushed with a pressure flush valve. All Essential Characteristics specified for class 1 products
in accordance with Annex ZA are satisfied:
EN 997 — CL 1 — 5/4 A — 6 C
EXAMPLE 2 Class 1 close coupled suite or one-piece WC pan with a flush volume of 6 l when flushed with a flushing
cistern equipped with a valve of reliability category II. The requirements for class 2 products are also satisfied:
EN 997 — CL 1 — 6 — VR II + CL 2
If class 1 close-coupled suites components (WC pan and flushing cistern) are delivered separately, both
components should be CE marked.
EXAMPLE 3 Class 2 WC suite for use with designated flushing cistern(s). All Essential Characteristics specified for
class 2 products in accordance with Annex ZA are satisfied:
EN 997 — CL 2
EXAMPLE 4 Class 1 close coupled suite for a flush volume of 6 l when flushed with a flushing cistern equipped with a
valve of reliability category II. The minimum supply pressure is specified by the manufacturer with 0,5 MPA (0,5 bar)
optional. All Essential Characteristics specified for Class 1 products in accordance with Annex ZA are satisfied. The
requirements for Class 2 products are also satisfied:
EN 997 — CL 1 — 6 / 0,5 — VR II + CL 2
EXAMPLE 5 Class 2 WC suite for use with designated flushing cistern(s). Minimum full flush volume 5,2 l is shown in
the designation code as an option. All Essential Characteristics specified for class 2 products in accordance with
Annex ZA are satisfied:
6

---------------------- Page: 8 ----------------------

SIST EN 997:2012/kFprA1:2015
EN 997:2012/FprA1:2014 (E)
EN 997 — CL 2 — 5.2
”.
5 Modification to Clause 8, Evaluation of conformity
Replace the former Clause 8 (now to be renumbered as Clause 9) with the following one:

9 Assessment and verification of constancy of performance – AVCP
9.1 General
The compliance of close-coupled suites, one-piece and independent WC pans with integral trap with the
requirements of this standard and with the performances declared by the manufacturer in the DoP shall be
demonstrated by:
— determination of the product type (see 9.2);
— factory production control by the manufacturer (FPC), including product assessment (see 9.3).
The manufacturer shall always retain the overall control and shall have the necessary means to take
responsibility for the conformity of the product with its declared performance(s).
9.2 Type testing
9.2.1 General
All performances related to characteristics included in this standard shall be determined when the
manufacturer intends to declare the respective performances unless the standard gives provisions for
declaring them without performing tests. (e.g. use of previously existing data, CWFT and conventionally
accepted performance).
Assessment previously performed in accordance with the provisions of this standard, may be taken into
account provided that they were made to the same or a more rigorous test method, under the same AVCP
system on the same product or products of similar design, construction and functionality, such that the results
are applicable to the product in question.
For the purposes of assessment, the manufacturer's products may be grouped into families, where it is
considered that the results for one or more characteristics from any one product within the family are
representative for that same characteristics for all products within that same family.
Products may be grouped in different families for different characteristics.
Reference to the assessment method standards should be made to allow the selection of a suitable
representative sample.
In addition, the determination of the product type shall be performed for all characteristics included in the
standard for which the manufacturer declares the performance:
— at the beginning of the production of a new or modified close-coupled suites, one-piece and independent
WC pans with integral trap (unless a member of the same product range), or
— at the beginning of a new or modified method of production (where this may affect the stated properties);
or
— they shall be repeated for the appropriate characteristic(s), whenever a change occurs in the modified
close-coupled suites, one-piece and independent WC pans with integral trap design, in the raw material
7

---------------------- Page: 9 ----------------------

SIST EN 997:2012/kFprA1:2015
EN 997:2012/FprA1:2014 (E)
or in the supplier of the components, or in the method of production (subject to the definition of a family),
which would affect significantly one or more of the characteristics.
Where components are used whose characteristics have already been determined, by the component
manufacturer, on the basis of assessment methods of other product standards, these characteristics need not
be re-assessed. The specifications of these components shall be documented.
Products bearing regulatory marking in accordance with appropriate harmonized European specifications may
be presumed to have the performances declared in the DoP, although this does not replace the responsibility
on the close-coupled suites, one-piece and independent WC pans with integral trap manufacturer to ensure
that the close-coupled suites, one-piece and independent WC pans with integral trap as a whole is correctly
manufactured and its component products have the declared performance values.
9.2.2 Test samples, testing and compliance criteria
The number of samples of close-coupled suites, one-piece and independent WC pans with integral trap to be
tested/assessed shall be in accordance with Table 6 and/or Table 7.
Table 6 — Type testing for class 1 products
Assessment method
Number of Requirement and
Characteristic to be tested according to clauses of
samples Compliance criteria
this standard
Depth of water seal 5.7.1 1 5.1
Wash of bowl 5.7.2.3 1 5.2.2
Flushing toilet paper 5.7.2.4 1 5.2.3
Flushing of 50 plastic balls 5.7.2.5 1 5.2.4
Oversplashing 5.7.2.6 1 5.2.5
After-flush volume 5.7.2.7 1 5.2.6
Water absorption 5.7.3 1 5.3
Static load 5.7.4 1 5.4
Flush volume(s) for flushing 5.7.5.1 1 5.5.4
cisterns of suites
Leaktightness between cistern 5.7.5.2 1 5.5.5
and bowl
Outlet valve leak tightness 5.7.5.3  a
5.5.6
Outlet valve reliability 5.7.5.4  a
5.5.7
Overflow 5.7.5.5 1 5.5.8
Safety margin – dimension c 5.7.5.6 1 5.5.9
Safety margin – dimension a 5.7.5.7 1 5.5.10
Dangerous substances 7 — —
a
Where an outlet valve is used in several cisterns, the outlet valve need only be tested once unless there are design
changes.

8

---------------------- Page: 10 ----------------------

SIST EN 997:2012/kFprA1:2015
EN 997:2012/FprA1:2014 (E)
Table 7 — Type testing for class 2 products
Characteristic to be tested Assessment method Number of Compliance criteria
According to clauses of samples
this standard
Inlet valve 6.17.1 1 6.1
Backflow prevention a 1 6.2
6.2
6.13
6.17.3
Flushing cistern marking 6.3 1 6.3
Warning pipe and overflow 6.17.2 1 6.4
provision
Flush volume 6.17.3 1 6.5
Flush rate 6.17.4 1 6.6
Flushing device: Physical 6.17.5 1 6.7
endurance and leakage
Flushing device: Chemical 6.17.6 1 6.8
endurance
Solids discharge and after 6.17.7 1 6.9
flush volume for maximum
flush
Paper discharge for reduced 6.17.8 1 6.10
flush volume
Liquid contaminant dye 6.17.9 1 6.11
retention
Wash of bowl 6.17.10 1 6.12
Water seal depth 6.17.3 1 6.13
Static load 5.8.4 1 6.14
Water absorption 5.8.3 1 6.15
Dangerous substances 7 — —
a
Foul air and water.

9.3 Factory production control (FPC)
9.3.1 General
The manufacturer shall establish, document and maintain an FPC system to ensure that the products placed
on the market comply with the declared performance of the essential characteristics.
The FPC system shall consist of procedures, regular inspections and tests and/or assessments and the use of
the results to control raw and other incoming materials or components, equipment, the production process and
the product.
The results of inspections, tests or assessments requiring action shall be recorded. The action to be then
when control values or criteria are not met shall be recorded.
NOTE Manufacturers having an FPC system which complies with EN ISO 9001 and which addresses the provisions
of the present European Standard are considered as satisfying the FPC requirements of the Regulation (EU)
No. 305/2011.
9

---------------------- Page: 11 ----------------------

SIST EN 997:2012/kFprA1:2015
EN 997:2012/FprA1:2014 (E)
9.3.2 Equipment
9.3.2.1 Testing
All weighing, measuring and testing equipment shall be calibrated and
...

Questions, Comments and Discussion