SIST EN 934-3:2009
(Main)Admixtures for concrete, mortar and grout - Part 3: Admixtures for masonry mortar - Definitions, requirements, conformity and marking and labelling
Admixtures for concrete, mortar and grout - Part 3: Admixtures for masonry mortar - Definitions, requirements, conformity and marking and labelling
This European Standard defines and specifies the requirements and conformity criteria for admixtures for use in cement based masonry mortar. It covers two types of admixtures, long term retarding and air entraining/plasticising which are used in ready-mixed and site made masonry mortars. Provisions for the use of admixtures for masonry mortar are not part of this European Standard but are covered by EN 998-1 and EN 998-2.
Zusatzmittel für Beton, Mörtel und Einpressmörtel - Teil 3: Zusatzmittel für Mauermörtel - Definitionen, Anforderungen, Konformität, Kennzeichnung und Beschriftung
Diese Europäische Norm enthält Anforderungen und Konformitätskriterien für Zusatzmittel für zementgebundenen
Mauermörtel.
Sie gilt für zwei Arten von Zusatzmitteln, Erstarrungsverzögerer für langzeitverzögerte Mauermörtel und
Luftporenbildner/Betonverflüssiger, die sowohl für Mörtel, der fertig gemischt auf die Baustelle geliefert wird,
als auch für Mörtel, der auf der Baustelle hergestellt wird, verwendet werden.
Festlegungen zur praktischen Anwendung von Zusatzmitteln für Mauermörtel sind nicht Bestandteil dieser
Europäischen Norm, sondern werden durch EN 998-1 und EN 998-2 erfasst.
Adjuvants pour béton, mortier et coulis - Adjuvants pour mortier à maçonner - Partie 3: Définitions, exigences, conformité, marquage et étiquetage
La présente Norme européenne définit et précise les exigences et les critères de conformité pour les adjuvants utilisés dans le mortier à maçonner à base de ciments. Il s'applique à deux types d'adjuvants, les adjuvants fortement retardateurs de prise et les adjuvants entraîneurs d'air / plastifiants utilisés dans le mortier prêt à l'emploi ainsi que dans le mortier fabriqué sur chantier. Les dispositions relatives à l’utilisation d'adjuvants de mortier à maçonner ne font pas partie de la présente norme européenne, mais de l’EN 998-1 et de l'EN 998-2.
Kemijski dodatki za beton, malto in injekcijsko maso - 3. del: Kemijski dodatki za malto za zidanje - Definicije, zahteve, skladnost, označevanje in obeleževanje
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 934-3:2009
01-november-2009
1DGRPHãþD
SIST EN 934-3:2004
SIST EN 934-3:2004/AC:2005
.HPLMVNLGRGDWNL]DEHWRQPDOWRLQLQMHNFLMVNRPDVRGHO.HPLMVNLGRGDWNL]D
PDOWR]D]LGDQMH'HILQLFLMH]DKWHYHVNODGQRVWR]QDþHYDQMHLQREHOHåHYDQMH
Admixtures for concrete, mortar and grout - Part 3: Admixtures for masonry mortar -
Definitions, requirements, conformity and marking and labelling
Zusatzmittel für Beton, Mörtel und Einpressmörtel - Teil 3: Zusatzmittel für Mauermörtel -
Definitionen, Anforderungen, Konformität, Kennzeichnung und Beschriftung
Adjuvants pour béton, mortier et coulis - Adjuvants pour mortier à maçonner - Partie 3:
Définitions, exigences, conformité, marquage et étiquetage
Ta slovenski standard je istoveten z: EN 934-3:2009
ICS:
01.040.91 Gradbeni materiali in gradnja Construction materials and
(Slovarji) building (Vocabularies)
91.100.10 Cement. Mavec. Apno. Malta Cement. Gypsum. Lime.
Mortar
SIST EN 934-3:2009 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 934-3:2009
---------------------- Page: 2 ----------------------
SIST EN 934-3:2009
EUROPEAN STANDARD
EN 934-3
NORME EUROPÉENNE
EUROPÄISCHE NORM
August 2009
ICS 91.100.30 Supersedes EN 934-3:2003
English Version
Admixtures for concrete, mortar and grout - Part 3: Admixtures
for masonry mortar - Definitions, requirements, conformity and
marking and labelling
Adjuvants pour béton, mortier et coulis - Partie 3: Adjuvants Zusatzmittel für Beton, Mörtel und Einpressmörtel - Teil 3:
pour mortier de montage - Définitions, exigences, Zusatzmittel für Mauermörtel - Definitionen, Anforderungen,
conformité, marquage et étiquetage Konformität, Kennzeichnung und Beschriftung
This European Standard was approved by CEN on 16 July 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2009 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 934-3:2009: E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 934-3:2009
EN 934-3:2009 (E)
Contents
page
Foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Requirements . 5
5 Sampling . 6
6 Conformity control. 7
7 Evaluation of conformity . 7
8 Marking and labelling . 8
8.1 General . 8
8.2 Designation of admixtures . 8
8.3 Additional information . 8
Annex A (informative) Content and release of dangerous substances . 9
Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU
Construction Products Directive . 10
ZA.1 Scope and relevant characteristics . 10
ZA.2 Procedure for attestation of conformity of admixtures for masonry mortar . 11
ZA.2.1 System of attestation of conformity . 11
ZA.2.2 EC certificate and declaration of conformity . 13
ZA.3 CE marking and labelling . 14
Bibiography . 16
2
---------------------- Page: 4 ----------------------
SIST EN 934-3:2009
EN 934-3:2009 (E)
Foreword
This document (EN 934-3:2009) has been prepared by Technical Committee CEN/TC 104 “Concrete and related
products”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by February 2010, and conflicting national standards shall be withdrawn at
the latest by February 2010.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 934-3:2003.
This European Standard has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive 89/106/EEC.
For relationship with EU Directive 89/106/EEC, see informative Annex ZA, which is an integral part of this
document.
This European Standard is a part of the series EN 934 "Admixtures for concrete, mortar and grout" which
additionally comprises the following parts
Part 1: Common requirements
Part 2 Admixtures for concrete, mortar and grout — Part 2: Concrete admixtures — Definitions, requirements,
conformity, marking and labelling
Part 4: Admixtures for grout for prestressing tendons — Definitions, requirements, conformity, marking and
labelling
Part 5: Admixtures for sprayed concrete — Definitions, requirements, conformity, marking and labelling
Part 6: Sampling, conformity control, evaluation of conformity
This European Standard is used with the standards of the EN 480 series which comprise test methods for
admixtures.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
3
---------------------- Page: 5 ----------------------
SIST EN 934-3:2009
EN 934-3:2009 (E)
1 Scope
This European Standard defines and specifies the requirements and conformity criteria for admixtures for use in
cement based masonry mortar.
It covers two types of admixtures, long term retarding and air entraining/plasticising which are used in ready-mixed
and site made masonry mortars.
Provisions for the use of admixtures for masonry mortar are not part of this European Standard but are covered by
EN 998-1 and EN 998-2.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references,
only the edition cited applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 480-13:2009, Admixtures for concrete, mortar and grout — Test methods — Part 13: Reference masonry
mortar for testing mortar admixtures
EN 934-1:2008, Admixtures for concrete, mortar and grout — Part 1: Common requirements
EN 934-2, Admixtures for concrete, mortar and grout — Part 2: Concrete admixtures — Definitions, requirements,
conformity, marking and labelling
EN 934-6:2001, Admixtures for concrete, mortar and grout - Part 6: Sampling, conformity control and evaluation of
conformity
EN 934-6:2001/A1:2005, Admixtures for concrete, mortar and grout — Part 6: Sampling, conformity control and
evaluation of conformity
EN 1015-4, Methods of test for mortar for masonry — Part 4: Determination of consistence of fresh mortar (by
plunger penetration)
EN 1015-7, Methods of test for mortar for masonry — Part 7: Determination of air content of fresh mortar
EN 1015-9, Methods of test for mortar for masonry — Part 9: Determination of workable life and correction time of
fresh mortar
EN 1015-11, Methods of test for mortar for masonry — Part 11: Determination of flexural and compressive strength
of hardened mortar
3 Terms and definitions
For the purposes of this document, the definitions in EN 934-1:2008 and the following apply.
3.1
air entraining/plasticizing admixture
admixture which increases workability, or allows water reduction, by incorporating during mixing a controlled
quantity of small, uniformly distributed air bubbles which remain after hardening
3.2
set retarding admixture for long term retarded masonry mortar
set retarding admixture as defined in EN 934-2 but specifically intended for use in long term retarded mortar
incorporating entrained air
4
---------------------- Page: 6 ----------------------
SIST EN 934-3:2009
EN 934-3:2009 (E)
3.3
performance
ability of an admixture to be effective in its intended use without detrimental effect
3.4
compliance dosage
dosage of an admixture, expressed in % by mass of cement, stated by the manufacturer, which will meet the
requirements of this European Standard. The compliance dosage is within the recommended range of dosage
3.5
recommended range of dosage
dosages between limits, expressed in % by mass of cement, which the manufacturer recommends for the product
based on experience on site
NOTE The use of the recommended dosage does not imply that compliance with this standard will be achieved over the
whole range. Trial tests should be carried out with the materials to be used on site, to find the dosage necessary to achieve the
required result.
3.6
maximum recommended dosage
upper limit of the recommended range of dosage
4 Requirements
Masonry mortar admixtures, when sampled in accordance with EN 934-6:2001 and EN 934-6/A1, shall comply with
the requirements in EN 934-1:2008, Table 1 using the test methods listed therein and the additional requirements
specific to different types of admixture listed in Table 1.
NOTE 1 Tests should be carried out with the admixtures and other materials intended to be used in the mortar to check
whether the desired effect can be obtained.
For content of substances and release of substances from the hardened mortar which are dangerous to health,
hygiene and the environment see Annex A (informative).
NOTE 2 For requirements necessary for CE-marking see Annex ZA.
Table 1 — Additional requirements for specific types of admixture
Definition Name of admixture Additional requirements
3.1 Air entraining/plasticizing mixture Table 2
3.2 Set retarding admixture for long term retarded Table 3
masonry mortar
5
---------------------- Page: 7 ----------------------
SIST EN 934-3:2009
EN 934-3:2009 (E)
Table 2 — Additional requirements for air entraining/plasticizing admixtures at equal consistence
a
Property Reference mortar Test method
Requirement
1 Air content after EN 480-13 EN 1015-7 Total air content A = (17 ± 3) % by
1
standard mixing volume
method A
2 Air content after 1 h standing EN 480-13 EN 1015-7 ≥ A – 3 %
1
method A
3 Air content after extended EN 480-13 EN 1015-7
≤ A + 5 % and ≥ A – 5 %
1 1
mixing
method A
4 Reduction in water EN 480-13 EN 480-13
≥ 8 % by mass
requirement for standard
consistence
5 Compressive strength at EN 480-13 EN 1015-11
Test mix ≥ 70 % of control mix
28 days
a
All requirements apply to the same test mix.
Table 3 — Additional requirements for admixtures for long term retarded, ready to use mortar at equal
d
consistence
a
Property Reference mortar Test method
Requirement
1 Air content after standard EN 480-13 EN 1015-7 Total air content
mixing method A A = (17 ± 3) % by volume
2
2 Air content after extended EN 480-13 EN 1015-7 ≤ A + 5 % and
2
mixing method A
≥ A – 5 %
2
3 Consistence after 28 h EN 480-13 EN 1015-4 Within 15 mm of initial value
b
standing
4 Air content after 28 h standing EN 480-13 EN 1015-7
≥ 0,70A %
2
method A
2
Resistance to penetration after
5 EN 480-13 EN 1015-9
Test mix ≥ 1,0 N/mm
c
72 h
6 Compressive strength at EN 480-13 EN 1015-11
Test mix ≥ 70 % of control mix
28 days
a
All requirements apply to the same test mix.
b
When stored and remixed in accordance with EN 480-13:2009, 5.3, as for determination of air content, after 28 h standing.
c
When stored in a covered mould for 28 h to prevent evaporation of water and then stored in an uncovered penetration
resistance mould for further 44 h at (65 ± 5) % RH.
d The air entrainment may be as a result of the admixture containing both retarding and air entraining properties or by the
separate addition of an air entraining admixture complying with Table 2.
5 Sampling
Requirements for sampling are given in EN 934-6:2001, Clause 4 and EN 934-6/A1:2005.
6
---------------------- Page: 8 ----------------------
SIST EN 934-3:2009
EN 934-3:2009 (E)
6 Conformity control
Requirements for conformity control are given in EN 934-6:2001/A1:2005, 5.3 and 5.4 and EN 934-6/A1:2005. The
frequency of testing in connection with the factory production control is given in Table 4.
Table 4 — Minimum frequency of test for factory production control
Air entraining/ Admixture for long term
Tests plasticizing retarded, ready to use
admixture mortar
Homogeneity, colour B B
Relative density (for liquids only) B B
Conventional dry material content B B
pH value (for liquids only) B B
a
4 4
Chloride content (CI)
Compressive strength at 28 days 1 1
Air content after standard mixing A A
Air content after extended mixing A A
Air content after 1 h standing A –
Air
...
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Zusatzmittel für Beton, Mörtel und Einpressmörtel - Teil 3: Zusatzmittel für Mauermörtel - Definitionen, Anforderungen, Konformität, Kennzeichnung und BeschriftungAdjuvants pour béton, mortier et coulis - Adjuvants pour mortier à maçonner - Partie 3: Définitions, exigences, conformité, marquage et étiquetageAdmixtures for concrete, mortar and grout - Part 3: Admixtures for masonry mortar - Definitions, requirements, conformity and marking and labelling91.100.10Cement. Mavec. Apno. MaltaCement. Gypsum. Lime. Mortar01.040.91Gradbeni materiali in gradnja (Slovarji)Construction materials and building (Vocabularies)ICS:Ta slovenski standard je istoveten z:prEN 934-3kSIST prEN 934-3:2009en,fr,de01-marec-2009kSIST prEN 934-3:2009SLOVENSKI
STANDARD
kSIST prEN 934-3:2009
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMFINAL DRAFTprEN 934-3January 2009ICS 01.040.91; 91.100.10Will supersede EN 934-3:2003
English VersionAdmixtures for concrete, mortar and grout - Part 3: Admixturesfor masonry mortar - Definitions, requirements, conformity andmarking and labellingAdjuvants pour béton, mortier et coulis - Adjuvants pourmortier à maçonner - Partie 3: Définitions, exigences,conformité, marquage et étiquetageZusatzmittel für Beton, Mörtel und Einpressmörtel - Teil 3:Zusatzmittel für Mauermörtel - Definitionen, Anforderungen,Konformität, Kennzeichnung und BeschriftungThis draft European Standard is submitted to CEN members for unique acceptance procedure. It has been drawn up by the TechnicalCommittee CEN/TC 104.If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations whichstipulate the conditions for giving this European Standard the status of a national standard without any alteration.This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other languagemade by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has thesame status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice andshall not be referred to as a European Standard.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre:
Avenue Marnix 17,
B-1000 Brussels© 2009 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. prEN 934-3:2009: EkSIST prEN 934-3:2009
prEN 934-3:2009 (E) 2 Contents page Foreword.3 1 Scope.4 2 Normative references.5 3 Terms and definitions.5 4 Requirements.6 5 Sampling.8 6 Conformity control.8 7 Evaluation of conformity.9 8 Marking and labelling.9 8.1 General.9 8.2 Designation of admixtures.9 8.3 Additional information.9 Annex A (informative)
Content and release of dangerous substances.10 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive.11 ZA.1 Scope and relevant characteristics.11 ZA.2 Procedure for attestation of conformity of admixtures for masonry mortar.12 ZA.2.1 System of attestation of conformity.12 ZA.2.2 EC certificate and declaration of conformity.14 ZA.3 CE marking and labelling.15 Bibiography.17
kSIST prEN 934-3:2009
prEN 934-3:2009 (E) 3 Foreword This document (prEN 934-3:2009) has been prepared by Technical Committee CEN/TC 104 “Concrete and related products”, the secretariat of which is held by DIN. This document is currently submitted to the Unique Acceptance Procedure. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This document will supersede EN 934-3:2003. This European Standard is a part of the series EN 934 "Admixtures for concrete, mortar and grout" which additionally comprises the following parts Part 1: Common requirements Part 2 Admixtures for concrete, mortar and grout — Part 2: Concrete admixtures — Definitions, requirements, conformity, marking and labelling
Part 4: Admixtures for grout for prestressing tendons — Definitions, requirements, conformity, marking and labelling Part 5: Admixtures for sprayed concrete — Definitions, requirements, conformity, marking and labelling Part 6: Sampling, conformity control, evaluation of conformity This European Standard is used with the standards of the EN 480 series which comprise test methods for admixtures.
kSIST prEN 934-3:2009
prEN 934-3:2009 (E) 4 1 Scope This European Standard defines and specifies the requirements and conformity criteria for admixtures for use in cement based masonry mortar. It covers two types of admixtures, long term retarding and air entraining/plasticising which are used in ready-mixed and site made masonry mortars. Provisions for the use of admixtures for masonry mortar are not part of this European Standard but are covered by EN 998-1 and EN 998-2.
kSIST prEN 934-3:2009
prEN 934-3:2009 (E) 5 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 480-13:2002, Admixtures for concrete, mortar and grout — Test methods — Part 13: Reference masonry mortar for testing mortar admixtures EN 934-1:2008, Admixtures for concrete, mortar and grout — Part 1: Common requirements EN 934-6:2001, Admixtures for concrete, mortar and grout — Part 6: Sampling, conformity control and evaluation of conformity EN 1015-4, Methods of test for mortar for masonry — Part 4: Determination of consistence of fresh mortar (by plunger penetration) EN 1015-7, Methods of test for mortar for masonry — Part 7: Determination of air content of fresh mortar EN 1015-9, Methods of test for mortar for masonry — Part 9: Determination of workable life and correction time of fresh mortar EN 1015-11, Methods of test for mortar for masonry — Part 11: Determination of flexural and compressive strength of hardened mortar 3 Terms and definitions For the purposes of this document, the definitions in EN 934-1:2008 and the following apply. 3.1 air entraining/plasticizing admixture admixture which increases workability, or allows water reduction, by incorporating during mixing a controlled quantity of small, uniformly distributed air bubbles which remain after hardening 3.2 set retarding admixture for long term retarded masonry mortar set retarding admixture as defined in EN 934-2 but specifically intended for use in long term retarded mortar incorporating entrained air 3.3 performance ability of an admixture to be effective in its intended use without detrimental effect 3.4 compliance dosage dosage of an admixture, expressed in % by mass of cement, stated by the manufacturer, which will meet the requirements of this European Standard. The compliance dosage is within the recommended range of dosage 3.5 recommended range of dosage dosages between limits, expressed in % by mass of cement, which the manufacturer recommends for the product based on experience on site NOTE The use of the recommended dosage does not imply that compliance with this standard will be achieved over the whole range. Trial tests should be carried out with the materials to be used on site, to find the dosage necessary to achieve the required result. kSIST prEN 934-3:2009
prEN 934-3:2009 (E) 6 3.6 maximum recommended dosage upper limit of the recommended range of dosage 4 Requirements Masonry mortar admixtures, when sampled in accordance with EN 934-6, shall comply with the requirements in
EN 934-1:2008 in Table 1 using the test methods listed therein and the additional requirements specific to different types of admixture listed in Table 1. NOTE 1 Tests should be carried out with the admixtures and other materials intended to be used in the mortar to check whether the desired effect can be obtained. For content of substances and release of substances from the hardened mortar which are dangerous to health, hygiene and the environment see Annex A (informative). NOTE 2 For requirements necessary for CE-marking see Annex ZA. Table 1 — Additional requirements for specific types of admixture Definition Name of admixture Additional requirements 3.1 Air entraining/plasticizing mixture Table 2 3.2 Set retarding admixture for long term retarded masonry mortar Table 3 kSIST prEN 934-3:2009
prEN 934-3:2009 (E) 7 Table 2 — Additional requirements for air entraining/plasticizing admixtures at equal consistence
Property Reference mortarTest methodRequirement a 1 Air content after standard mixing EN 480-13 EN 1015-7 method A Total air content A1 = (17 ± 3) % by volume 2 Air content after 1 h standing EN 480-13 EN 1015-7 method A ≥ A1 – 3 % 3 Air content after extended mixing EN 480-13 EN 1015-7 method A ≤ A1 + 5 % and ≥ A1 – 5 % 4 Reduction in water requirement for standard consistence EN 480-13 EN 480-13 ≥ 8 % by mass 5 Compressive strength at 28 days EN 480-13 EN 1015-11 Test mix ≥ 70 % of control mix a All requirements apply to the same test mix.
Table 3 — Additional requirements for admixtures for long term retarded, ready to use mortar at equal consistence d
Property Reference mortarTest methodRequirement a 1 Air content after standard mixing EN 480-13 EN 1015-7 method A Total air content A2 = (17 ± 3) % by volume 2 Air content after extended mixing EN 480-13 EN 1015-7 method A ≤ A2 + 5 % and ≥ A2 – 5 % 3 Consistence after 28 h
standing b EN 480-13 EN 1015-4 Within 15 mm of initial value 4 Air content after 28 h standing EN 480-13 EN 1015-7 method A ≥ 0,70A2 % 5 Resistance to penetration after 72 h c EN 480-13 EN 1015-9 Test mix ≥ 1,0 N/mm2 6 Compressive strength at
28 days EN 480-13 EN 1015-11 Test mix ≥ 70 % of control mixa All requirements apply to the same test mix. b When stored and remixed in accordance with EN 480-13:2002, 5.3, as for determination of air content, after 28 h standing.c When stored in a covered mould for 28 h to prevent evaporation of water and then stared in an uncovered penetration
resistance mould for further 44 h at (65 ± 5) % RH. d The air entrainment may be as a result of the admixture containing both retarding and air entraining properties or by the
separate addition of an air entraining admixture complying with Table 2. kSIST prEN 934-3:2009
prEN 934-3:2009 (E) 8 5 Sampling Requirements for sampling are given in EN 934-6:2001, Clause 4. 6 Conformity control Requirements for conformity control are given in EN 934-6:2001, 5.3 and 5.4. The frequency of testing in connection with the factory production control is given in Table 4. Table 4 — Minimum frequency of test for factory production control Tests Air entraining/ plasticizing admixture Admixture for long term retarded, ready to use mortar Homogeneity, colour B B Relative density (for liquids only) B B Conventional dry material content B B pH value (for liquids only) B B Chloride content (CI) a 4 4 Compressive strength at 28 days 1 1 Air content after standard mixing A A Air content after extended mixing A A Air content after 1 h standing A – Air content after 28 h standing – A Reduction in water requirement for
standard consistence A – Consistence after 28 h standing
– A Resistance to penetration after 72 h – A Numbers in this table denote minimum frequency of test per year, spread according to production; if the production is less frequent every batch has to be tested
A: means test for every 500 t with a minimum of 2 times a year B: means test for each batch NOTE The effective component (infrared analysis) need not be included in the programme of factory production control. It has be included in initial type testing. a Total ch
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.