SIST EN 1329-1:2014
(Main)Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
This part of EN 1329 specifies the requirements for solid wall unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and the system intended for:
— soil and waste discharge applications (low and high temperature) inside buildings (application area code “B”);
— soil and waste discharge applications (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code “BD”).
NOTE 1 The intended use is reflected in the marking of products by “B” or “BD”. NOTE 2 For use buried in ground within the building structure are intended only those components (marked with “BD”) with nominal outside diameters equal to or greater than 75 mm. This part of EN 1329 is also applicable to PVC-U pipes, fittings and the system intended for the following purposes:
— ventilating part of the pipework in association with discharge applications;
— rainwater pipework within the building structure.
It also specifies the test parameters for the test method referred to in this European Standard. This European Standard covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. For external above ground application additional requirements depending on the climate should be agreed between the manufacturer and the user. NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this European Standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 24. NOTE 5 Joints and adhesives are considered to be part of the system as covered in the scope.
Kunststoff-Rohrleitungssysteme zum Ableiten von Abwasser (niedriger und hoher Temperatur) innerhalb der Gebäudestruktur - Weichmacherfreies Polyvinylchlorid (PVC U) - Teil 1: Anforderungen an Rohre, Formstücke und das Rohrleitungssystem
Der vorliegende Teil der EN 1329 legt die Anforderungen an Rohre, Formstücke und das Rohrleitungssystem fest für Vollwand-Rohrleitungssysteme aus weichmacherfreiem Polyvinylchlorid (PVC U) für Anlagen zum Ableiten von Abwasser (niedriger und hoher Temperatur):
innerhalb von Gebäuden (Anwendungskennzeichen „B“);
sowohl innerhalb von Gebäuden als auch erdverlegt innerhalb der Gebäudestruktur (Anwendungskenn-zeichen „BD“).
ANMERKUNG 1 Der vorgesehene Verwendungszweck wird durch die Kennzeichnung der Erzeugnisse mit „B“ und „BD“ angezeigt.
ANMERKUNG 2 Für erdverlegte Anwendungen innerhalb der Gebäudestruktur dürfen nur Rohrleitungsteile (gekenn-zeichnet mit „BD“) mit einem Nenn-Außendurchmesser von mindestens 75 mm eingesetzt werden.
Der vorliegende Teil der EN 1329 gilt ebenfalls für Rohre, Formstücke und das Rohrleitungssystem aus PVC U für die folgenden Verwendungszwecke:
Lüftungsleitungen in Verbindung mit Abwasseranwendungen;
Regenwasserleitungen innerhalb der Gebäudestruktur.
Er legt auch die die Prüfparameter für das Prüfverfahren fest, auf das in dieser Norm verwiesen wird.
Diese Norm behandelt einen Nennweitenbereich, einen Bereich von Rohr- und Formstückreihen sowie Empfehlungen für die Einfärbung.
ANMERKUNG 3 Die geeignete Auswahl aus diesen Aspekten unter Berücksichtigung der jeweils geltenden Anforde-rungen sowie aller maßgebenden nationalen Bestimmungen und Verlegeverfahren oder vorschriften liegt in der Verantwortung des Kunden oder Auftraggebers.
Für oberirdische Anwendungen außerhalb von Gebäuden sollten zusätzliche klimabezogene Anforde¬rungen zwischen Hersteller und Anwender vereinbart werden.
ANMERKUNG 4 Rohre, Formstücke und andere Rohrleitungsteile nach einer der in Anhang B aufgeführten Normen zu Kunststofferzeugnissen können mit Rohren und Formstücken nach der vorliegenden Europäischen Norm verwendet werden, sofern sie den Anforderungen an die Maße von Verbindungen nach Abschnitt 6 und den Anforderungen nach Tabelle 15 entsprechen.
ANMERKUNG 5 Verbindungen und Klebstoffe werden als Teil des Rohrleitungssystems entsprechend des Anwendungs¬bereichs angesehen.
Systèmes de canalisations en plastique pour l'évacuation des eaux-vannes et des eaux usées (à basse et à haute température) à l'intérieur de la structure des bâtiments - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 1: Spécifications pour tubes, raccords et le système
Cette partie de l’EN 1329 spécifie les exigences pour les tubes à paroi compacte en poly(chlorure de vinyle) non plastifié (PVC U), les raccords et le systèmes destinés à être utilisés pour :
les applications d’évacuation des eaux-vannes et des eaux usées (à basse et à haute température) à l'intérieur des bâtiments (code de zone d’application « B ») ;
les applications d'évacuation des eaux-vannes et des eaux usées (à basse et à haute température) utilisables aussi bien à l'intérieur des bâtiments qu'en enterré dans la structure du bâtiment (code de zone d’application « BD »).
NOTE 1 L’utilisation prévue est repérée au niveau du marquage des produits par « B » ou «BD».
NOTE 2 Seuls sont destinés à l'usage en enterré dans la structure du bâtiment, les composants (marqués "BD") avec un diamètre extérieur nominal égal ou supérieur à 75 mm.
Cette partie de l’EN 1329 est également applicable aux tubes en PVC U, raccords et le système destinés aux usages suivants :
la partie de ventilation du réseau de canalisation en association avec des applications d’évacuation des eaux-usées ;
canalisations pour les eaux pluviales à l'intérieur de la structure du bâtiment.
Elle spécifie également les paramètres d'essai pour les méthodes d'essai référencées dans la présente norme.
La présente norme couvre une gamme de dimensions nominales, une gamme de tubes et de raccords et donne des recommandations concernant les couleurs.
NOTE 3 Il est de la responsabilité de l'acheteur ou du prescripteur d'effectuer les sélections appropriées à partir de ces données en tenant compte des exigences particulières, des éventuelles règles nationales appropriées et des pratiques ou codes de pose.
Pour une application externe en aérien il convient de spécifier des exigences supplémentaires dépendant du climat entre le fabricant et l'utilisateur.
NOTE 4 Les tubes, les raccords et autres composants conformes à l'une des normes de produits plastiques listées dans l'Annexe B peuvent être utilisés avec des tubes et des raccords conformes à la présente Norme européenne dans la mesure où ils répondent aux exigences pour les dimensions d'assemblage données dans l'Article 6 et aux exigences du Tableau 15.
NOTE 5 Les joints et adhésifs sont considérés comme faisant partie du système tel que couvert dans le domaine d’application.
Cevni sistemi iz polimernih materialov za nizko- in visokotemperaturne odvodne sisteme v zgradbah - Nemehčan polivinilklorid (PVC-U) - 1. del: Zahteve za cevi, fitinge in sistem
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kunststoff-Rohrleitungssysteme zum Ableiten von Abwasser (niedriger und hoher Temperatur) innerhalb der Gebäudestruktur - Weichmacherfreies Polyvinylchlorid (PVC U) - Teil 1: Anforderungen an Rohre, Formstücke und das RohrleitungssystemSystèmes de canalisations en plastique pour l'évacuation des eaux-vannes et des eaux usées (à basse et à haute température) à l'intérieur de la structure des bâtiments - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 1: Spécifications pour tubes, raccords et le systèmePlastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system91.140.80Drenažni sistemiDrainage systems23.040.20Cevi iz polimernih materialovPlastics pipesICS:Ta slovenski standard je istoveten z:EN 1329-1:2014SIST EN 1329-1:2014en,fr,de01-april-2014SIST EN 1329-1:2014SLOVENSKI
STANDARDSIST EN 1329-1:19991DGRPHãþD
SIST EN 1329-1:2014
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1329-1
February 2014 ICS 23.040.01 Supersedes EN 1329-1:1999English Version
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
Systèmes de canalisations en plastique pour l'évacuation des eaux-vannes et des eaux usées (à basse et à haute température) à l'intérieur de la structure des bâtiments - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 1: Spécifications pour tubes, raccords et le système
Kunststoff-Rohrleitungssysteme zum Ableiten von Abwasser (niedriger und hoher Temperatur) innerhalb der Gebäudestruktur - Weichmacherfreies Polyvinylchlorid (PVC U) - Teil 1: Anforderungen an Rohre, Formstücke und das Rohrleitungssystem This European Standard was approved by CEN on 1 December 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1329-1:2014 ESIST EN 1329-1:2014
EN 1329-1:2014 (E) 2 Contents
Page Foreword .4 1 Scope .5 2 Normative references .5 3 Terms and definitions, symbols and abbreviations .7 3.1 Terms and definitions .7 3.2 Symbols .9 3.3 Abbreviations . 10 4 Material . 10 4.1 Raw material . 10 4.2 Additional requirement for pipe material for BD application . 11 4.3 Additional requirement for fitting material for BD application . 11 4.4 Utilization of non-virgin material . 11 4.5 Sealing ring retaining means . 12 5 General characteristics . 12 5.1 Appearance . 12 5.2 Colour . 12 6 Geometrical characteristics . 12 6.1 General . 12 6.2 Dimensions of pipes . 12 6.2.1 Outside diameter. 12 6.2.2 Out-of-roundness. 13 6.2.3 Effective length of pipes . 13 6.2.4 Chamfering . 14 6.2.5 Wall thickness . 14 6.2.6 Dimensions of sockets . 15 6.3 Dimensions of fittings . 15 6.3.1 General . 15 6.3.2 Outside diameters. 17 6.3.3 Wall thicknesses . 17 6.3.4 Types of fittings . 19 6.3.5 Design lengths . 20 6.4 Diameters and lengths of sockets and spigot . 22 6.4.1 Adhesive joint sockets and spigot. 22 6.4.2 Ring seal sockets and spigot . 23 6.4.3 One-piece expansion couplings for adhesive joint sockets and spigot . 26 7 Mechanical characteristics . 27 7.1 Mechanical characteristics of pipes . 27 7.1.1 General requirements . 27 7.1.2 Additional requirements . 29 7.2 Mechanical characteristics of fittings. 29 8 Physical characteristics . 30 8.1 Physical characteristics of pipes . 30 8.2 Physical characteristics of fittings . 30 9 Performance requirements . 31 10 Sealing rings . 32 11 Adhesives . 32 SIST EN 1329-1:2014
EN 1329-1:2014 (E) 3 12 Marking . 33 12.1 General . 33 12.2 Minimum required marking of pipes . 33 12.3 Minimum required marking of fittings . 34 12.4 Additional marking . 34 Annex A (normative)
Utilization of non-virgin material . 35 A.1 Own reprocessed material. 35 A.2 External reprocessed and recycled materials with agreed specifications . 35 A.3 External reprocessed and recycled material not covered by an agreed specification . 37 A.4 Summary of use of non-virgin material . 38 Annex B (informative)
Product standards . 39 Annex C (informative)
Correspondence between ISO test methods and CEN test methods . 40 Bibliography . 41
SIST EN 1329-1:2014
EN 1329-1:2014 (E) 4 Foreword This document (EN 1329-1:2014) has been prepared by Technical Committee CEN/TC 155 “Plastics piping systems and ducting systems”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2014, and conflicting national standards shall be withdrawn at the latest by August 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1329-1:1999. EN 1329 consists of the following parts: — EN 1329-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: Specifications for pipes, fittings and the system [the present document]; — CEN/TS 1329-2, Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Guidance for the assessment of conformity [Technical Specification]. The main changes are: — specification of the scope with restriction to solid wall; — updating of the normative references; — alignments of products characteristics for BD applications with UD applications (EN 1401-1) for dn ≥ 110 mm; — introduction of alternative test methods to DCMT for the evaluation of the gelation of PVC; — explicit integration of designs of fittings. System Standards are based on the results of the work undertaken in ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids”, which is a Technical Committee of the International Organization for Standardization (ISO). They are supported by separate standards on test method to which references are made throughout the System Standard. The System Standards are consistent with general standards on functional requirements and on recommended practice for installation. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 1329-1:2014
EN 1329-1:2014 (E) 5 1 Scope This part of EN 1329 specifies the requirements for solid wall unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and the system intended for: — soil and waste discharge applications (low and high temperature) inside buildings (application area code “B”); — soil and waste discharge applications (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code “BD”). NOTE 1 The intended use is reflected in the marking of products by “B” or “BD”. NOTE 2 For use buried in ground within the building structure are intended only those components (marked with “BD”) with nominal outside diameters equal to or greater than 75 mm. This part of EN 1329 is also applicable to PVC-U pipes, fittings and the system intended for the following purposes: — ventilating part of the pipework in association with discharge applications; — rainwater pipework within the building structure. It also specifies the test parameters for the test method referred to in this European Standard. This European Standard covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. For external above ground application additional requirements depending on the climate should be agreed between the manufacturer and the user. NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this European Standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 24. NOTE 5 Joints and adhesives are considered to be part of the system as covered in the scope. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 681-1, Elastomeric seals - Materials requirements for pipe joint seals used in water and drainage applications - Part 1: Vulcanized rubber EN 681-2, Elastomeric Seals - Materials requirements for pipe joint seals used in water and drainage applications - Part 2: Thermoplastic elastomers EN 1401-1:2009, Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system EN 1905, Plastics piping systems - Unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and material - Method for assessment of the PVC content based on total chlorine content SIST EN 1329-1:2014
EN 1329-1:2014 (E) 6 EN 10204:2004, Metallic products - Types of inspection documents EN 14680, Adhesives for non-pressure thermoplastic piping systems - Specifications EN 14814, Adhesives for thermoplastic piping systems for fluids under pressure - Specifications EN ISO 472, Plastics - Vocabulary (ISO 472) EN ISO 580, Plastics piping and ducting systems - Injection-moulded thermoplastics fittings - Methods for visually assessing the effects of heating (ISO 580) EN ISO 1043-1, Plastics - Symbols and abbreviated terms - Part 1: Basic polymers and their special characteristics (ISO 1043-1) EN ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids - Determination of the resistance to internal pressure - Part 1: General method (ISO 1167-1) EN ISO 1167-2, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids - Determination of the resistance to internal pressure - Part 2: Preparation of pipe test pieces (ISO 1167-2) EN ISO 1183-1, Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method (ISO 1183-1) EN ISO 2505, Thermoplastics pipes - Longitudinal reversion - Test method and parameters (ISO 2505) EN ISO 3126, Plastics piping systems - Plastics components - Determination of dimensions (ISO 3126) EN ISO 6259-1, Thermoplastics pipes - Determination of tensile properties - Part 1: General test method (ISO 6259-1) EN ISO 13229, Thermoplastics piping systems for non-pressure applications - Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings - Determination of the viscosity number and K-value (ISO 13229) ISO 2507-1, Thermoplastics pipes and fittings - Vicat softening temperature - Part 1: General test method ISO 3127, Thermoplastics pipes - Determination of resistance to external blows - Round-the-clock method ISO 6259-2, Thermoplastics pipes - Determination of tensile properties - Part 2: Pipes made of unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly (vinyl chloride) (PVC-C) and high-impact poly (vinyl chloride) (PVC-HI) ISO 9852, Unplasticized poly(vinyl chloride) (PVC-U) pipes - Dichloromethane resistance at specified temperature (DCMT) - Test method ISO 11173, Thermoplastics pipes - Determination of resistance to external blows - Staircase method ISO 13254, Thermoplastics piping systems for non-pressure applications - Test method for watertightness ISO 13255, Thermoplastics piping systems for soil and waste discharge inside buildings - Test method for airtightness of joints ISO 13257:2010, Thermoplastics piping systems for non-pressure applications - Test method for resistance to elevated temperature cycling ISO 13259, Thermoplastics piping systems for underground non-pressure applications - Test method for leaktightness of elastomeric sealing ring type joints SIST EN 1329-1:2014
EN 1329-1:2014 (E) 7 ISO 18373-1, Rigid PVC pipes - Differential scanning calorimetry (DSC) method - Part 1: Measurement of the processing temperature 3 Terms and definitions, symbols and abbreviations 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 472 and EN ISO 1043-1 and the following apply. 3.1.1 application area code code used in the marking of pipes and fittings to indicate the application area(s) for which they are intended, as follows: — B: application area code for components intended for use above ground inside the building, or for components outside buildings fixed onto the wall; — D: application code for the area under and within 1 m from the building where the pipes and fittings are buried in ground and are connected to the underground drainage and sewerage system; — BD: application area code for components intended for use for both code B and code D application areas Note 1 to entry: In D application areas the existence of external forces from the surroundings in addition to the hot water discharge is usual. Note 2 to entry: Other application area codes U and UD not covered by this standard are defined elsewhere, e.g. in EN 1401–1. 3.1.2 nominal size 3.1.2.1 nominal size DN numerical designation of the size of a component, other than a component designated by thread size, which is approximately equal to the manufacturing dimension, in millimetres 3.1.2.2 nominal size DN/OD nominal size, related to the outside diameter 3.1.3 nominal outside diameter dn specified outside diameter, in millimetres, assigned to a nominal size DN/OD 3.1.4 outside diameter de value of the measurement of the outside diameter through its cross section at any point of a pipe or spigot of a fitting, rounded to the next greater 0,1 mm SIST EN 1329-1:2014
EN 1329-1:2014 (E) 8 3.1.5 mean outside diameter dem value of the measurement of the outer circumference of a pipe or spigot of a fitting in any cross section, divided by π (≈ 3,142), rounded to the next greater 0,1 mm 3.1.6 inside diameter ds value of the measurement of the inside diameter through its cross section at any point of a socket, rounded to the next greater 0,1 mm 3.1.7 mean inside diameter of a socket dsm arithmetical mean of a number of measurements of the inside diameter of a socket in the same cross section 3.1.8 out-of-roundness ovality difference between the measured maximum and the measured minimum outside diameter in the same cross section of a component 3.1.9 wall thickness e value of measurement of the wall thickness at any point around the circumference of a component 3.1.10 mean wall thickness em arithmetical mean of a number of measurements of the wall thickness, regularly spaced around the circumference and in the same cross section of a component, including the measured minimum and the measured maximum values of the wall thickness in that cross section 3.1.11 standard dimension ratio SDR nominal ratio of the outside diameter, dn, to the minimum wall thickness, emin 3.1.12 nominal ring stiffness SN numerical designation of the ring stiffness of a pipe or fitting which is a convenient round number relative to the determined stiffness in kilonewtons per square metre, indicating the minimum ring stiffness of a pipe or fitting 3.1.13 assembled fittings fittings which are made from several injection moulded parts to be assembled together by screwing or clipping Note 1 to entry: Such fittings can incorporate rubber membranes or joints. SIST EN 1329-1:2014
EN 1329-1:2014 (E) 9 3.1.14 fabricated fittings fittings produced from pipe and/or from injection-moulded fittings by thermoforming, solvent-cementing or welding Note 1 to entry: Fabricated fittings need an additional fabrication step. 3.1.15 solid wall pipe and fitting pipe or fitting with smooth internal and external surface with the same compound / formulation through the wall 3.1.16 material definitions 3.1.16.1 virgin material material in the form such as granules or powder that has not been subjected to use or processing other than that required for its manufacture and to which no reprocessed or recycled material has been added Note 1 to entry: It is understood that the addition of additives such as stabilizers and pigments is still resulting into a virgin material. 3.1.16.2 own reprocessed material material prepared from rejected unused pipes, gutters or fittings and ancillaries, including trimmings from the production of pipes or fittings, that has been reprocessed in a manufacturer's plant after having been previously processed by the same manufacturer by a process such as moulding or extrusion, and for which the complete formulation is known 3.1.16.3 external reprocessed material material prepared from unused thermoplastics products regardless of where those products were manufactured 3.1.16.4 recycled material material from used thermoplastic products which have been cleaned and crushed or ground 3.1.16.5 reformulated material recycled/reprocessed material that has been reformulated, by additives and processing techniques, to meet an agreed specification Note 1 to entry: Typically the additives used would be stabilizers, pigments etc.; the reformulation material: homogeneous pellets, granules, powder etc., with the produced batch having consistent physical properties. 3.1.16.6 agreed specification specification of the relevant material characteristics agreed between the supplier of the non-virgin material and the pipe, fitting and/or ancillary manufacturer 3.2 Symbols A : length of engagement C : depth of sealing zone de
: outside diameter dem : mean outside diameter SIST EN 1329-1:2014
EN 1329-1:2014 (E) 10 dn : nominal outside diameter ds : inside diameter of a socket dsm : mean inside diameter of a socket e : wall thickness em : mean wall thickness e2 : wall thickness of a socket e3 : wall thickness in the groove area L1 : length of spigot L2 : length of socket l : effective length of a pipe R : radius of swept fittings Z : design length of a fitting . : nominal angle of a fitting 3.3 Abbreviations DN : nominal size DN/OD : nominal size, outside diameter related PVC-U : Unplasticised poly(vinyl chloride) SDR : Standard dimension ratio SN : Nominal ring stiffness TIR : True impact rate 4 Material 4.1 Raw material The raw material shall be PVC-U to which are added those additives that are needed to facilitate the manufacture of components conforming to the requirements of this European Standard. The PVC content shall be at least 80 % by mass for pipes and 85 % by mass for injection-moulded fittings and shall be determined by calculation. In case of dispute, the PVC content can also be determined in accordance with EN 1905. For pipes ≥ 110 mm and intended for BD applications, a further reduction of the PVC-U content to ≥ 75 % by mass for pipes only is permitted provided the PVC-U is substituted by coated or uncoated CaCO3 conforming to the following: a) The composition of the CaCO3, before coating if any, shall conform to the following: 1) content of CaCO3 ≥ 96 % by mass; 2) content of MgCO3 ≤ 4 % by mass; 3) content of CaCO3 and MgCO3 in total ≥ 98 % by mass. b) The physical properties of the material shall conform to the following: 1) mean particle size D50 ≤ 2,5
SIST EN 1329-1:2014
EN 1329-1:2014 (E) 11 2) top cut D98 ≤ 20
4.2 Additional requirement for pipe material for BD application The material of pipes intended to be used in application area BD shall comply with the additional requirement given in Table 1, when tested in accordance with the methods and the parameters indicated in Table 1. The pipe material shall be tested in the form of a pipe. Table 1 — Material characteristics of pipes intended for BD application Characteristic Requirements Test parameters Test method Resistance to internal pressure No failure during the test period End caps Test temperature Orientation Number of test pieces Circumferential (hoop) stress Conditioning period Type of test Test period Type A or B 60 °C Free 3 10,0 MPa 1 h Water-in-water 1 000 h EN ISO 1167-1 and EN ISO 1167-2 4.3 Additional requirement for fitting material for BD application The material of fittings intended to be used in application area BD shall comply with the additional requirement given in Table 2, when tested in accordance with the methods and the parameters indicated in Table 2. The fitting material shall be tested in the form of an extruded or injection-moulded pipe. Table 2 — Material characteristics of fittings intended for BD application Characteristic Requirements Test parameters Test method Resistance to internal pressure No failure during the test period End caps Dimensions Test temperature Orientation Free length for injection-moulded pipe Number of test pieces Circumferential (hoop) stress Conditioning period Type of test Test period Type A or B 50 mm ≤ dn ≤ 110 mm 60 °C Free ≥ 140 mm 3 6,3 MPa 1 h Water-in-water 1 000 h EN ISO 1167-1
and
EN ISO 1167-2 4.4 Utilization of non-virgin material Conditions and requirements for the utilization of non-virgin material are given in Annex A. SIST EN 1329-1:2014
EN 1329-1:2014 (E) 12 4.5 Sealing ring retaining means Sealing rings may be retained using mean
...
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kunststoff-Rohrleitungssysteme zum Ableiten von Abwasser (niedriger und hoher Temperatur) innerhalb der Gebäudestruktur - Weichmacherfreies Polyvinylchlorid (PVC U) - Teil 1: Anforderungen an Rohre, Formstücke und das RohrleitungssystemSystèmes de canalisations en plastique pour l'évacuation des eaux-vannes et des eaux usées (à basse et à haute température) à l'intérieur de la structure des bâtiments - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 1: Spécifications pour tubes, raccords et le systèmePlastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system91.140.80Drenažni sistemiDrainage systems23.040.01Deli cevovodov in cevovodi na splošnoPipeline components and pipelines in generalICS:Ta slovenski standard je istoveten z:FprEN 1329-1kSIST FprEN 1329-1:2013en,fr,de01-september-2013kSIST FprEN 1329-1:2013SLOVENSKI
STANDARD
kSIST FprEN 1329-1:2013
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
FINAL DRAFT
FprEN 1329-1
May 2013 ICS 23.040.01 Will supersede EN 1329-1:1999English Version
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
Systèmes de canalisations en plastique pour l'évacuation des eaux-vannes et des eaux usées (à basse et à haute température) à l'intérieur de la structure des bâtiments - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 1: Spécifications pour tubes, raccords et le système
Kunststoff-Rohrleitungssysteme zum Ableiten von Abwasser (niedriger und hoher Temperatur) innerhalb der Gebäudestruktur - Weichmacherfreies Polyvinylchlorid (PVC U) - Teil 1: Anforderungen an Rohre, Formstücke und das Rohrleitungssystem This draft European Standard is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee CEN/TC 155.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. FprEN 1329-1:2013: EkSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 2 Contents
Page Foreword . 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions, symbols and abbreviations . 7 3.1 Terms and definitions . 7 3.2 Symbols . 9 3.3 Abbreviations . 10 4 Material . 10 4.1 Raw material . 10 4.2 Additional requirement for pipe material for BD application . 11 4.3 Additional requirement for fitting material for BD application . 11 4.4 Utilisation of non-virgin material . 12 4.5 Sealing ring retaining means . 12 5 General characteristics . 12 5.1 Appearance . 12 5.2 Colour . 12 6 Geometrical characteristics . 12 6.1 General . 12 6.2 Dimensions of pipes . 12 6.2.1 Outside diameter . 12 6.2.2 Out-of-roundness . 13 6.2.3 Effective length of pipes . 13 6.2.4 Chamfering . 14 6.2.5 Wall thickness . 14 6.2.6 Dimensions of sockets . 15 6.3 Dimensions of fittings . 15 6.3.1 General . 15 6.3.2 Outside diameters . 16 6.3.3 Wall thicknesses . 17 6.3.4 Types of fittings . 19 6.3.5 Design lengths . 20 6.4 Diameters and lengths of sockets and spigot . 22 6.4.1 Adhesive joint sockets and spigot . 22 6.4.2 Ring seal sockets and spigot . 23 6.4.3 One-piece expansion couplings for adhesive joint sockets and spigot . 26 7 Mechanical characteristics . 27 7.1 Mechanical characteristics of pipes . 27 7.1.1 General requirements . 27 7.1.2 Additional requirements . 29 7.2 Mechanical characteristics of fittings . 29 8 Physical characteristics . 30 8.1 Physical characteristics of pipes . 30 8.2 Physical characteristics of fittings . 30 9 Performance requirements . 31 10 Sealing rings . 32 11 Adhesives . 32 12 Marking . 33 kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 3 12.1 General . 33 12.2 Minimum required marking of pipes . 33 12.3 Minimum required marking of fittings . 34 12.4 Additional marking . 34 Annex A (normative)
Utilisation of non-virgin material . 35 A.1 Own reprocessed material . 35 A.2 External reprocessed and recycled materials with agreed specifications . 35 A.2.1 Material from PVC-U pipes and fitting . 35 A.2.2 Material from PVC-U products other than pipes and fittings . 36 A.2.3 Reformulated material . 37 A.3 External reprocessed and recycled material not covered by an agreed specification . 37 A.3.1 Material from PVC-U pipes and fittings . 37 A.3.2 Material from other PVC-U products than pipes and fittings . 38 A.4 Summary of use of non-virgin material . 38 Annex B (informative)
Product standards . 39 Annex C (informative)
Correspondence between ISO test methods and CEN test methods . 40 Bibliography . 41
kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 4 Foreword This document (FprEN 1329-1:2013) has been prepared by Technical Committee CEN/TC 155 “Plastics piping systems and ducting systems”, the secretariat of which is held by NEN. This document is currently submitted to the Unique Acceptance Procedure. This document will supersede EN 1329-1:1999. EN 1329 consists of the following parts: EN 1329-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: Specifications for pipes, fittings and the system [the present document]; CEN/TS 1329-2, Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Guidance for the assessment of conformity [Technical Specification]. The main changes are: specification of the scope with restriction to solid wall; updating of the normative references; alignments of products characteristics for BD applications with UD applications (EN 1401-1) for dn ≥ 110 mm; introduction of alternative test methods to DCMT for the evaluation of the gelation of PVC; explicit integration of designs of fittings. System Standards are based on the results of the work undertaken in ISO/TC 138 "Plastics pipes, fittings and valves for the transport of fluids", which is a Technical Committee of the International Organization for Standardization (ISO). They are supported by separate standards on test method to which references are made throughout the System Standard. The System Standards are consistent with general standards on functional requirements and on recommended practice for installation.
kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 5 1 Scope This part of EN 1329 specifies the requirements for solid wall unplasticised poly(vinyl chloride) (PVC-U) pipes, fittings and the system intended for: soil and waste discharge applications (low and high temperature) inside buildings (application area code "B"); soil and waste discharge applications (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code "BD"). NOTE 1 The intended use is reflected in the marking of products by "B" or "BD". NOTE 2 For use buried in ground within the building structure are intended only those components (marked with "BD") with nominal outside diameters equal to or greater than 75 mm. This part of EN 1329 is also applicable to PVC-U pipes, fittings and the system intended for the following purposes: ventilating part of the pipework in association with discharge applications; rainwater pipework within the building structure. It also specifies the test parameters for the test method referred to in this standard. This standard covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. For external above ground application additional requirements depending on the climate should be agreed between the manufacturer and the user. NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this European Standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 15. NOTE 5 Joints and adhesives are considered to be part of the system as covered in the scope. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 681-1, Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 1: Vulcanized rubber EN 681-2, Elastomeric Seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 2: Thermoplastics elastomers EN 1401-1:2009, Plastics piping systems for non-pressure underground drainage and sewerage — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: Specifications for pipes, fittings and the system EN 1905, Plastics piping systems — Unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and material — Method for assessment of the PVC content based on total chlorine content kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 6 EN 10204:2004, Metallic products — Types of inspection documents EN 14680, Adhesives for non-pressure thermoplastic piping systems — Specifications EN 14814, Adhesives for thermoplastic piping systems for fluids under pressure — Specifications EN ISO 472, Plastics — Vocabulary (ISO 472) EN ISO 580, Plastics piping and ducting systems — Injection-moulded thermoplastics fittings — Methods for visually assessing the effects of heating (ISO 580) EN ISO 1043-1, Plastics — Symbols and abbreviated terms — Part 1: Basic polymers and their special characteristics (ISO 1043-1) EN ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 1: General method (ISO 1167-1) EN ISO 1167-2, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 2: Preparation of pipe test pieces (ISO 1167-2) EN ISO 1183-1, Plastics — Methods for determining the density of non-cellular plastics — Part 1: Immersion method, liquid pyknometer method and titration method (ISO 1183-1) EN ISO 2505, Thermoplastics pipes — Longitudinal reversion — Test method and parameters (ISO 2505) EN ISO 3126, Plastics piping systems — Plastics components — Determination of dimensions (ISO 3126) EN ISO 6259-1, Thermoplastics pipes — Determination of tensile properties — Part 1: General test method (ISO 6259-1) EN ISO 13229, Thermoplastics piping systems for non-pressure applications — Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings — Determination of the viscosity number and K-value (ISO 13229) ISO 2507-1, Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method ISO 3127, Thermoplastics pipes — Determination of resistance to external blows — Round-the-clock method ISO 6259-2, Thermoplastics pipes — Determination of tensile properties — Part 2: Pipes made of unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C) and high-impact poly (vinyl chloride) (PVC-HI) ISO 9852, Unplasticized poly(vinyl chloride) (PVC-U) pipes — Dichloromethane resistance at specified temperature (DCMT) — Test method ISO 11173, Thermoplastics pipes — Determination of resistance to external blows — Staircase method ISO 13254, Thermoplastics piping systems for non-pressure applications — Test method for watertightness
ISO 13255, Thermoplastics piping systems for soil and waste discharge inside buildings — Test method for airtightness of joints ISO 13257:2010, Thermoplastics piping systems for non-pressure applications — Test method for resistance to elevated temperature cycling ISO 13259, Thermoplastics piping systems for underground non-pressure applications — Test method for leaktightness of elastomeric sealing ring type joints kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 7 ISO 18373-1, Rigid PVC pipes — Differential scanning calorimetry (DSC) method — Part 1: Measurement of the processing temperature 3 Terms and definitions, symbols and abbreviations 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 472 and EN ISO 1043-1 and the following apply. 3.1.1 application area code code used in the marking of pipes and fittings to indicate the application area(s) for which they are intended, as follows: B: application area code for components intended for use above ground inside the building, or for components outside buildings fixed onto the wall;
D: application code for the area under and within 1 m from the building where the pipes and fittings are buried in ground and are connected to the underground drainage and sewerage system; BD: application area code for components intended for use for both code B and code D application areas Note 1 to entry: In D application areas the existence of external forces from the surroundings in addition to the hot water discharge is usual. Note 2 to entry: Other application area codes U and UD not covered by this standard are defined elsewhere, e.g. in EN 1401-1. 3.1.2 nominal size
3.1.2.1 nominal size DN numerical designation of the size of a component, other than a component designated by thread size, which is approximately equal to the manufacturing dimension, in millimetres 3.1.2.2 nominal size DN/OD nominal size, related to the outside diameter 3.1.3 nominal outside diameter dn specified outside diameter, in millimetres, assigned to a nominal size DN/OD 3.1.4 outside diameter de value of the measurement of the outside diameter through its cross section at any point of a pipe or spigot of a fitting, rounded to the next greater 0,1 mm kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 8 3.1.5 mean outside diameter dem value of the measurement of the outer circumference of a pipe or spigot of a fitting in any cross section, divided by π (≈ 3,142), rounded to the next greater 0,1 mm 3.1.6
inside diameter ds value of the measurement of the inside diameter through its cross section at any point of a pipe or spigot of a fitting, rounded to the next greater 0,1 mm 3.1.7 mean inside diameter of a socket dsm arithmetical mean of a number of measurements of the inside diameter of a socket in the same cross section 3.1.8 out-of-roundness ovality difference between the measured maximum and the measured minimum outside diameter in the same cross section of a component 3.1.9 wall thickness e value of measurement of the wall thickness at any point around the circumference of a component 3.1.10 mean wall thickness em arithmetical mean of a number of measurements of the wall thickness, regularly spaced around the circumference and in the same cross section of a component, including the measured minimum and the measured maximum values of the wall thickness in that cross section 3.1.11 standard dimension ratio SDR nominal ratio of the outside diameter, dn, to the minimum wall thickness, emin 3.1.12 nominal ring stiffness SN numerical designation of the ring stiffness of a pipe or fitting which is a convenient round number relative to the determined stiffness in kilonewtons per square metre, indicating the minimum ring stiffness of a pipe or fitting 3.1.13 assembled fittings fittings which are made from several injection moulded parts to be assembled together by screwing or clipping Note 1 to entry: Such fittings can incorporate rubber membranes or joints. 3.1.14 fabricated fittings fittings produced from pipe and/or from injection-moulded fittings by thermoforming, solvent-cementing or welding Note 1 to entry: Fabricated fittings need an additional fabrication step. kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 9 3.1.15 solid wall pipe and fitting pipe or fitting with smooth internal and external surface with the same compound / formulation through the wall 3.1.16 material definitions
3.1.16.1 virgin material material in the form such as granules or powder that has not been subjected to use or processing other than that required for its manufacture and to which no reprocessed or recycled material has been added Note 1 to entry: It is understood that the addition of additives such as stabilisers and pigments is still resulting into a virgin material. 3.1.16.2 own reprocessed material material prepared from rejected unused pipes, gutters or fittings and ancillaries, including trimmings from the production of pipes or fittings, that has been reprocessed in a manufacturer's plant after having been previously processed by the same manufacturer by a process such as moulding or extrusion, and for which the complete formulation is known 3.1.16.3 external reprocessed material material prepared from unused thermoplastics products regardless of where those products were manufactured 3.1.16.4 recycled material material from used thermoplastic products which have been cleaned and crushed or ground 3.1.16.5 reformulated material recycled/reprocessed material that has been reformulated, by additives and processing techniques, to meet an agreed specification Note 1 to entry: Typically the additives used would be stabilisers, pigments etc.; the reformulation material: homogeneous pellets, granules, powder etc., with the produced batch having consistent physical properties. 3.1.16.6 agreed specification specification of the relevant material characteristics agreed between the supplier of the non-virgin material and the pipe, fitting and/or ancillary manufacturer 3.2 Symbols A : length of engagement C : depth of sealing zone de
: outside diameter dem : mean outside diameter dn : nominal outside diameter ds : inside diameter of a socket kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 10 dsm : mean inside diameter of a socket e : wall thickness em : mean wall thickness e2 : wall thickness of a socket e3 : wall thickness in the groove area L1 : length of spigot L2 : length of socket l : effective length of a pipe R : radius of swept fittings Z : design length of a fitting α : nominal angle of a fitting 3.3 Abbreviations DN : nominal size DN/OD : nominal size, outside diameter related PVC-U : Unplasticised poly(vinyl chloride) SDR : Standard dimension ratio SN : Nominal ring stiffness TIR : True impact rate 4 Material 4.1 Raw material The raw material shall be PVC-U to which are added those additives that are needed to facilitate the manufacture of components conforming to the requirements of this standard. The PVC content shall be at least 80 % by mass for pipes and 85 % by mass for injection-moulded fittings and shall be determined by calculation. In case of dispute, the PVC content can also be determined in accordance with EN 1905. For pipes ≥ 110 mm and intended for BD applications, a further reduction of the PVC-U content to ≥ 75 % by mass for pipes only is permitted provided the PVC-U is substituted by coated or uncoated CaCO3 conforming to the following: a) The composition of the CaCO3, before coating if any, shall conform to the following: 1) content of CaCO3 ≥ 96 % by mass; 2) content of MgCO3 ≤ 4 % by mass; 3) content of CaCO3 and MgCO3 in total ≥ 98 % by mass. kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 11 b) The physical properties of the material shall conform to the following: 1) mean particle size D50 ≤ 2,5
2) top cut D98 ≤ 20
4.2 Additional requirement for pipe material for BD application The material of pipes intended to be used in application area BD shall comply with the additional requirement given in Table 1, when tested in accordance with the methods and the parameters indicated in Table 1. The pipe material shall be tested in the form of a pipe. Table 1 — Material characteristics of pipes intended for BD application Characteristic Requirements Test parameters Test method Resistance to internal pressure No failure during the test period End caps
Test temperature Orientation
Number of test pieces Circumferential (hoop)
stress Conditioning period Type of test Test period Type A or B 60 °C Free 3 10,0 MPa
1 h Water-in-water 1 000 h EN ISO 1167-1 and EN ISO 1167-2
4.3 Additional requirement for fitting material for BD application The material of fittings intended to be used in application area BD shall comply with the additional requirement given in Table 2, when tested in accordance with the methods and the parameters indicated in Table 2. The fitting material shall be tested in the form of an extruded or injection-moulded pipe. Table 2 — Material characteristics of fittings intended for BD application Characteristic Requirements Test parameters Test method Resistance to internal pressure No failure during the test period End caps Dimensions Test temperature Orientation Free length for injection-moulded pipe Number of test pieces Circumferential (hoop)
stress Conditioning period Type of test Test period Type A or B 50 mm ≤ dn ≤ 110 mm 60 °C Free ≥ 140 mm
3 6,3 MPa
1 h Water-in-water 1 000 h EN ISO 1167-1
and
EN ISO 1167-2
kSIST FprEN 1329-1:2013
FprEN 1329-1:2013 (E) 12 4.4 Utilisation of non-virgin material Conditions and requirements for the utilisation of non-virgin material are given in Annex A. 4.5 Sealing ring retaining means Sealing rings may be retained using means made from polym
...
Questions, Comments and Discussion