Measurement of radioactivity - Measurement and evaluation of surface contamination - Part 2: Test method using wipe-test samples

ISO 7503 (all parts) and ISO 8769 are addressed to the people responsible for measuring the radioactivity present on solid surfaces.
ISO 7503-2:2016 applies to the evaluation of contamination on surfaces in terms of activity per unit area by an indirect method of measurement.
ISO 7503-2:2016 is applicable to well-defined surfaces, such as those of equipment and facilities, containers of radioactive materials, sealed sources and buildings or land.
ISO 7503-2:2016 can be used for laboratory and equipment/installation control and for remediation and monitoring activities to comply with release criteria.
ISO 7503-2:2016 also refers to institutions/authorities controlling nuclear material transports or material/equipment clearance according to national legislation guideline values or international convention limits.
ISO 7503-2:2016 does not apply to contamination of the skin, clothing or loose material, such as gravel.
NOTE Direct evaluation of surface contamination from alpha-emitters, beta-emitters and photon emitters is dealt with in ISO 7503-1. The calibration of instruments for the evaluation of radioactive surface contaminations is dealt with in ISO 7503-3.

Mesurage de la radioactivité — Mesurage et évaluation de la contamination de surface — Partie 2: Méthode d'essai utilisant des échantillons d'essai de frottis

L'ISO 7503 (toutes les parties) et l'ISO 8769 s'adressent aux personnes chargées de mesurer la radioactivité présente sur des surfaces solides.
ISO 7503-2:2017 de l'ISO 7503 s'applique à l'évaluation de la contamination des surfaces en termes d'activité surfacique, par une méthode de mesure indirecte.
ISO 7503-2:2017 est applicable aux surfaces bien définies, telles que celles des équipements et des installations, des conteneurs de matières radioactives, des sources scellées et des bâtiments ou des sols.
ISO 7503-2:2017 peut être utilisée pour le contrôle en laboratoire et des équipements/installations ainsi que pour les activités de réhabilitation et de surveillance visant à établir la conformité aux critères de libération.
ISO 7503-2:2017 se réfère également aux institutions/autorités chargées du contrôle des transports de matières nucléaires ou de la déclassification des matériels/équipements conformément aux valeurs indicatives des législations nationales ou aux limites des conventions internationales.
ISO 7503-2:2017 ne s'applique pas à la contamination de la peau, des vêtements ou des matériaux en vrac (gravier, par exemple).
NOTE L'évaluation directe de la contamination de surface par les émetteurs alpha, bêta et photoniques est traitée dans l'ISO 7503‑1. L'étalonnage des instruments utilisés pour l'évaluation de la contamination des surfaces radioactives est traité dans l'ISO 7503‑3.

Merjenje radioaktivnosti - Merjenje in vrednotenje površinske kontaminacije - 2. del: Preskusna metoda z uporabo vzorcev za brisanje

General Information

Status
Not Published
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
29-Oct-2024
Due Date
03-Jan-2025

Buy Standard

Standard
ISO 7503-2:2016 - Measurement of radioactivity - Measurement and evaluation of surface contamination
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 7503-2:2016 - Mesurage de la radioactivité -- Mesurage et évaluation de la contamination de surface
French language
12 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 7503-2
Second edition
2016-01-15
Measurement of radioactivity -
Measurement and evaluation of
surface contamination —
Part 2:
Test method using wipe-test samples
Mesurage de la radioactivité — Mesurage et évaluation de la
contamination de surface —
Partie 2: Méthode d’essai utilisant des échantillons d’essai de frottis
Reference number
©
ISO 2016
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions, symbols and abbreviations . 2
3.1 Terms and definitions . 2
3.2 Symbols and abbreviated terms. 3
4 Sources of surface contamination . 3
5 Objectives of the surface contamination evaluation . 4
6 Strategy. 4
7 Methods for evaluating surface contamination . 4
8 Wipe test material . 5
9 Instrumentation . 5
9.1 General . 5
9.2 Liquid scintillation counters . 6
10 Calibration . 6
10.1 Calibration of installed instruments. 6
10.2 Calibration of portable instruments . 6
11 Guidelines on wipe test sampling . 6
11.1 General . 6
11.2 Guidelines on sampling removable tritium contamination . 7
12 Measurement procedure . 7
13 Evaluation of measurement data. 8
13.1 Calculation of the activity per unit area for measurement results of installed instruments 8
13.2 Calculation of the activity per unit area for measurement results of portable instruments 9
13.3 Application of ISO 11929 . 9
14 Wipe test uncertainties . 9
15 Test report . 9
Bibliography .11
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical
Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information
The committee responsible for this document is Technical Committee ISO/TC 85, Nuclear energy, nuclear
technologies, and radiological protection, Subcommittee SC 2, Radiological protection.
This second edition cancels and replaces the first edition (ISO 7503-2:1988), which has been
technically revised.
ISO 7503 consists of the following parts, under the general title Measurement of radioactivity —
Measurement and evaluation of surface contamination:
— Part 1: General principles
— Part 2: Test method using wipe-test samples
— Part 3: Apparatus calibration
iv © ISO 2016 – All rights reserved

Introduction
ISO 7503 gives guidance on the measurement of surface contamination. This International Standard is
applicable to many situations where radioactive contamination can occur. Contamination arises from
the release of radioactivity into the local environment. In most circumstances, the release is inadvertent
but, on occasion, may be deliberate. Although the purpose and scope of the investigation may differ, the
approaches taken to measure the levels and extent of the contamination are essentially similar.
Radioactive contamination can arise from a number of activities or events such as the following:
— routine laboratory use of radiochemicals;
— medical treatments;
— industrial applications;
— transport accidents;
— equipment malfunctions;
— malevolent incidents;
— nuclear accidents.
Without process knowledge or documentation, it is not always possible to identify or distinguish the
different radionuclides constituting a surface contamination, and the evaluation of such contamination
cannot be made on a quantitative basis. Instead of using instruments with nuclide specific calibrations,
it may be necessary to use other instruments which are fit for such a purpose.
However, there may be cases (e.g. a contaminated fuel material transport container) where the
radionuclide or the radionuclide mixture can be clearly characterized. A surface contamination
evaluation exceeding a pure qualitative assessment of fixed and removable surface contamination
may then be needed. Moreover, following requirements laid down in national regulations and in
international conventions, a measured surface contamination activity per unit area has to be compared
with surface contamination guideline values or surface contamination limits.
Surface contamination guideline values are radionuclide-specific and thus require complex
radionuclide-specific calibrations of measurement equipment. Calibration quality assurance is crucial
in order to avoid non-detection (i.e. type II decision errors) leading to incorrectly assuming compliance
with given surface contamination guideline values or limits. Evaluation of surfaces contaminated by a
mixture of radionuclides with known ratios requires respectively proportionated calibration factors.
ISO 7503 is concerned with the measurement and estimation of radioactivity levels. It does not provide
advice on decommissioning, planning and surveillance techniques.
Surface contamination is specified in terms of activity per unit area and the limits are based on the
recommendations by the International Commission on Radiological Protection (ICRP 103).
This part of ISO 7503 deals with the evaluation of surface contamination by indirect measurement
using a wipe test.
INTERNATIONAL STANDARD ISO 7503-2:2016(E)
Measurement of radioactivity - Measurement and
evaluation of surface contamination —
Part 2:
Test method using wipe-test samples
1 Scope
ISO 7503 (all parts) and ISO 8769 are addressed to the people responsible for measuring the
radioactivity present on solid surfaces.
This part of ISO 7503 applies to the evaluation of contamination on surfaces in terms of activity per unit
area by an indirect method of measurement.
This part of ISO 7503 is applicable to well-defined surfaces, such as those of equipment and facilities,
containers of radioactive materials, sealed sources and buildings or land.
This part of ISO 7503 can be used for laboratory and equipment/installation control and for remediation
and monitoring activities to comply with release criteria.
This part of ISO 7503 also refers to institutions/authorities controlling nuclear material transports
or material/equipment clearance according to national legislation guideline values or international
convention limits.
This part of ISO 7503 does not apply to contamination of the skin, clothing or loose material, such as gravel.
NOTE Direct evaluation of surface contamination from alpha-emitters, beta-emitters and photon emitters is
dealt with in ISO 7503-1. The calibration of instruments for the evaluation of radioactive surface contaminations
is dealt with in ISO 7503-3.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 8769, Reference sources — Calibration of surface contamination monitors — Alpha-, beta- and
photon emitters
ISO 9698, Water quality — Determination of tritium activity concentration — Liquid scintillation
counting method
ISO 11929, Determination of the characteristic limits (decision threshold, detection limit and limits of the
confidence interval) for measurements of ionizing radiation — Fundamentals and application
ISO 18589-2, Measurement of radioactivity in the environment — Soil — Part 2: Guidance for the selection
of the sampling strategy, sampling and pre-treatment of samples
ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories
IEC 60325, Radiation protection instrumentation — Alpha, beta and alpha/beta (beta energy >60 keV)
contamination meters and monitors
3 Terms and definitions,
...


NORME ISO
INTERNATIONALE 7503-2
Deuxième édition
2016-01-15
Mesurage de la radioactivité —
Mesurage et évaluation de la
contamination de surface —
Partie 2:
Méthode d’essai utilisant des
échantillons d’essai de frottis
Measurement of radioactivity - Measurement and evaluation of
surface contamination —
Part 2: Test method using wipe-test samples
Numéro de référence
©
ISO 2016
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2016, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – Tous droits réservés

Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions, symboles et abréviations . 2
3.1 Termes et définitions . 2
3.2 Symboles et abréviations . 3
4 Sources de contamination de surface . 3
5 Objectifs de l’évaluation de la contamination de surface . 4
6 Stratégie . 4
7 Méthodes pour évaluer la contamination de surface . 5
8 Matériau de prélèvement par frottis . 5
9 Instrumentation . 6
9.1 Généralités . 6
9.2 Compteurs à scintillation liquide . 6
10 Étalonnage . 7
10.1 Étalonnage des instruments fixes . 7
10.2 Étalonnage des instruments portatifs. 7
11 Lignes directrices pour le prélèvement par frottis . 7
11.1 Généralités . 7
11.2 Lignes directrices pour le prélèvement de la contamination par le tritium non fixée. 7
12 Mode opératoire de mesure . 8
13 Évaluation des données de mesure . 9
13.1 Calcul de l’activité surfacique pour les résultats de mesure des instruments fixes . 9
13.2 Calcul de l’activité surfacique pour les résultats de mesure des instruments portatifs . 9
13.3 Application de l’ISO 11929 .10
14 Incertitude des essais par frottis .10
15 Rapport d’essai .10
Bibliographie .12
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’OMC concernant les obstacles techniques au commerce (OTC), voir le lien
suivant: www.iso.org/iso/fr/foreword.html.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 85, Énergie nucléaire, technologies
nucléaires et radioprotection, Sous-comité SC 2, Radioprotection.
Cette deuxième édition annule et remplace la première édition (ISO 7503-2:1988), qui a fait l’objet d’une
révision technique.
L’ISO 7503 comprend les parties suivantes, présentées sous le titre général Mesurage de la radioactivité —
Mesurage et évaluation de la contamination de surface:
— Partie 1: Principes généraux
— Partie 2: Méthode d’essai utilisant des échantillons d’essai de frottis
— Partie 3: Étalonnage de l’appareillage
iv © ISO 2016 – Tous droits réservés

Introduction
L’ISO 7503 fournit des lignes directrices pour le mesurage de la contamination de surface. La présente
Norme internationale est applicable à de nombreuses situations où peut survenir une contamination
radioactive résultant d’un rejet radioactif dans l’environnement local. Dans la majorité des cas, ce rejet
est accidentel mais il peut parfois être délibéré. Bien que le but et le domaine d’application de l’étude
puissent différer, les approches adoptées pour mesurer les niveaux et l’étendue de la contamination
sont sensiblement similaires.
La contamination radioactive peut résulter d’un certain nombre d’activités ou d’événements tels que:
— l’utilisation régulière de produits radiochimiques en laboratoire;
— les traitements médicaux;
— les applications industrielles;
— les accidents de transport;
— les dysfonctionnements d’équipements;
— les incidents malveillants;
— les accidents nucléaires.
Sans connaissance des processus ni documentation, il n’est pas toujours possible d’identifier ou de
distinguer les différents radionucléides constituant une contamination de surface et cette contamination
ne peut pas être évaluée sur une base quantitative. Au lieu d’utiliser des instruments dont l’étalonnage est
spécifique à un nucléide, il peut être nécessaire d’utiliser des instruments spécialement conçus à cet effet.
Cependant, il peut exister certaines situations (contamination d’un conteneur de transport de
combustible, par exemple) où le radionucléide ou le mélange de radionucléides peut être clairement
caractérisé. Une évaluation de la contamination de surface allant au-delà d’une pure évaluation
qualitative de la contamination de surface fixée et non fixée peut alors être requise. En outre, sur la base
des exigences exposées dans les réglementations nationales et dans les conventions internationales, une
activité surfacique de la contamination de surface mesurée doit être comparée à des valeurs indicatives
et des limites de contamination de surface.
Les valeurs indicatives de contamination de surface sont spécifiques aux radionucléides et peuvent
donc nécessiter un étalonnage spécifique complexe des radionucléides de l’équipement de mesure.
L ‘assurance qualité de l’étalonnage est cruciale pour éviter une non-détection (c’est-à-dire les erreurs
de décision de type II) conduisant à supposer, à tort, la conformité aux valeurs indicatives ou aux
limites données de contamination de surface. L’évaluation des surfaces contaminées par un mélange
de radionucléides dont les rapports sont connus nécessite des facteurs d’étalonnage respectivement
proportionnels.
L’ISO 7503 porte sur le mesurage et l’estimation des niveaux de radioactivité. Elle ne donne aucun
conseil sur les techniques de déclassement, de planification et de surveillance.
La contamination de surface est spécifiée en termes d’activité surfacique et les limites sont fondées sur
les recommandations de la Commission Internationale de Protection Radiologique (ICRP 103).
La présente partie de l’ISO 7503 traite de l’évaluation de la contamination de surface par mesurage
indirect en utilisant un essai par frottis.
NORME INTERNATIONALE ISO 7503-2:2016(F)
Mesurage de la radioactivité — Mesurage et évaluation de
la contamination de surface —
Partie 2:
Méthode d’essai utilisant des échantillons d’essai de frottis
1 Domaine d’application
L’ISO 7503 (toutes les parties) et l’ISO 8769 s’adressent aux personnes chargées de mesurer la
radioactivité présente sur des surfaces solides.
La présente partie de l’ISO 7503 s’applique à l’évaluation de la contamination des surfaces en termes
d’activité surfacique, par une méthode de mesure indirecte.
La présente partie de l’ISO 7503 est applicable aux surfaces bien définies, telles que celles des
équipements et des installations, des conteneurs de matières radioactives, des sources scellées et des
bâtiments ou des sols.
La présente partie de l’ISO 7503 peut être utilisée pour le contrôle en laboratoire et des
équipements/installations ainsi que pour les activités de réhabilitation et de surveillance visant à
établir la conformité aux critères de libération.
La présente partie de l’ISO 7503 se réfère également aux institutions/autorités chargées du contrôle des
transports de matières nucléaires ou de la déclassification des matériels/équipements conformément
aux valeurs indicatives des législations nationales ou aux limites des conventions internationales.
La présente partie de l’ISO 7503 ne s’applique pas à la contamination de la peau, des vêtements ou des
matériaux en vrac (gravier, par exemple).
NOTE L’évaluation directe de la contamination de surface par les émetteurs alpha, bêta et photoniques est
traitée dans l’ISO 7503-1. L’étalonnage des instruments utilisés pour l’évaluation de la contamination des surfaces
radioactives est traité dans l’ISO 7503-3.
2 Références normatives
Les documents ci-après, dans leur intégralité ou non, sont des références normatives indispensables à
l’application du présent document. Pour les références datées, seule l’édition citée s’appl
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.