Industrial communication networks - Fieldbus specifications - Part 5-3: Application layer service definition - Type 3 elements (IEC 61158-5-3:2010)

This standard is one of a series produced to facilitate the interconnection of automation system components. It is related to other standards in the set as defined by the “three-layer” fieldbus reference model described in IEC/TR 61158-1. This sub-part contains material specific to Type 3 fieldbus.

Industrielle Kommunikationsnetze - Feldbusse - Teil 5-3: Dienstfestlegungen des Application Layer (Anwendungsschicht) - Typ 3-Elemente (IEC 61158-5-3:2010)

Réseaux de communication industriels - Spécifications des bus de terrain - Partie 5-3: Définition des services des couches d'application - Eléments de type 3 (IEC 61158-5-3:2010)

Industrijska komunikacijska omrežja - Specifikacije za procesno vodilo - 5-3. del: Definicija opravil na aplikacijskem nivoju - Elementi tipa 3 (IEC 61158-5-3:2010)

Ta standard spada v skupino standardov, namenjenih spodbujanju medsebojne povezave sestavnih delov avtomatizacijskega sistema. Povezan je z drugimi standardi v sklopu, kakor je opredeljeno s »trinivojskim« referenčnim modelom procesnih vodil iz standarda IEC/TR 61158-1. Ta poddel vsebuje material, specifičen za procesna vodila tipa 3.

General Information

Status
Withdrawn
Publication Date
09-Jul-2012
Withdrawal Date
27-Oct-2016
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
27-Oct-2016
Due Date
19-Nov-2016
Completion Date
28-Oct-2016

Relations

Buy Standard

Standard
EN 61158-5-3:2012 - BARVE
English language
441 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61158-5-3:2012
01-september-2012
1DGRPHãþD
SIST EN 61158-5-3:2008
Industrijska komunikacijska omrežja - Specifikacije za procesno vodilo - 5-3. del:
Definicija opravil na aplikacijskem nivoju - Elementi tipa 3 (IEC 61158-5-3:2010)
Industrial communication networks - Fieldbus specifications - Part 5-3: Application layer
service definition - Type 3 elements (IEC 61158-5-3:2010)
Industrielle Kommunikationsnetze - Feldbusse - Teil 5-3: Dienstfestlegungen des
Application Layer (Anwendungsschicht) - Typ 3-Elemente (IEC 61158-5-3:2010)
Réseaux de communication industriels - Spécifications des bus de terrain - Partie 5-3:
Définition des services des couches d'application - Eléments de type 3 (IEC 61158-5-
3:2010)
Ta slovenski standard je istoveten z: EN 61158-5-3:2012
ICS:
25.040.40 Merjenje in krmiljenje Industrial process
industrijskih postopkov measurement and control
35.100.70 Uporabniški sloj Application layer
35.110 Omreževanje Networking
SIST EN 61158-5-3:2012 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61158-5-3:2012

---------------------- Page: 2 ----------------------

SIST EN 61158-5-3:2012

EUROPEAN STANDARD
EN 61158-5-3

NORME EUROPÉENNE
June 2012
EUROPÄISCHE NORM

ICS 25.040.40; 35.100.70; 35.110 Supersedes EN 61158-5-3:2008


English version


Industrial communication networks -
Fieldbus specifications -
Part 5-3: Application layer service definition -
Type 3 elements
(IEC 61158-5-3:2010)


Réseaux de communication industriels -  Industrielle Kommunikationsnetze -
Spécifications des bus de terrain - Feldbusse -
Partie 5-3: Définition des services des Teil 5-3: Dienstfestlegungen des
couches d'application - Application Layer (Anwendungsschicht) -
Eléments de type 3 Typ 3-Elemente
(CEI 61158-5-3:2010) (IEC 61158-5-3:2010)





This European Standard was approved by CENELEC on 2012-03-28. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61158-5-3:2012 E

---------------------- Page: 3 ----------------------

SIST EN 61158-5-3:2012
EN 61158-5-3:2012 - 2 -

Foreword
The text of document 65C/606/FDIS, future edition 2 of IEC 61158-5-3, prepared by SC 65C, "Industrial
networks", of IEC/TC 65, "Industrial-process measurement, control and automation" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 61158-5-3:2012.

The following dates are fixed:
(dop) 2012-12-28
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2015-03-28

standards conflicting with the
document have to be withdrawn

This document supersedes EN 61158-5-3:2008.
EN 61158-5-3:2012 includes the following significant technical change with respect to EN 61158-5-
3:2008:
— Correction in 6.2.3.2.3.2 (referencing the error-codes in EN 61158-6-3:2012, 5.3.17 to maintain the
codes only in one place).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.

Endorsement notice
The text of the International Standard IEC 61158-5-3:2010 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC/TR 61158-1:2010 NOTE  Harmonized as CLC/TR 61158-1:2010 (not modified).
IEC 61158-6-10:2010 NOTE  Harmonized as EN 61158-6-10:2012 (not modified).

---------------------- Page: 4 ----------------------

SIST EN 61158-5-3:2012
- 3 - EN 61158-5-3:2012

Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 61131-1 - Programmable controllers - EN 61131-1 -
Part 1: General information


IEC 61158-3-3 2007 Industrial communication networks - Fieldbus EN 61158-3-3 2008
specifications -
Part 3-3: Data-link layer service definition -
Type 3 elements


IEC 61158-4-3 2010 Industrial communication networks - Fieldbus EN 61158-4-3 2012
specifications -
Part 4-3: Data-link layer protocol specification
- Type 3 elements


IEC 61158-5-10 2010 Industrial communication networks - Fieldbus EN 61158-5-10 2012
specifications -
Part 5-10: Application layer service definition -
Type 10 elements


IEC 61158-6-3 2010 Industrial communication networks - Fieldbus EN 61158-6-3 2012
specifications -
Part 6-3: Application layer protocol
specification - Type 3 elements


ISO/IEC 7498-1 - Information technology - Open Systems - -
Interconnection - Basic Reference Model:
The Basic Model


ISO/IEC 8822 - Information technology - Open Systems - -
Interconnection - Presentation service
definition


ISO/IEC 8824 - Information technology - Open Systems - -
Interconnection - Specification of Abstract
Syntax Notation One (ASN.1)


ISO/IEC 9545 - Information technology - Open Systems - -
Interconnection - Application Layer structure


ISO/IEC 10731 - Information technology - Open Systems - -
Interconnection - Basic reference model -
Conventions for the definition of OSI services

---------------------- Page: 5 ----------------------

SIST EN 61158-5-3:2012

---------------------- Page: 6 ----------------------

SIST EN 61158-5-3:2012

IEC 61158-5-3
®
Edition 2.0 2010-08
INTERNATIONAL
STANDARD

colour
inside

Industrial communication networks – Fieldbus specifications –
Part 5 3: Application layer service definition – Type 3 elements


INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
XP
ICS 25.04.40; 35.100.70; 35.110 ISBN 978-2-88912-106-9
® Registered trademark of the International Electrotechnical Commission

---------------------- Page: 7 ----------------------

SIST EN 61158-5-3:2012
– 2 – 61158-5-3 © IEC:2010(E)
CONTENTS
FOREWORD.11
INTRODUCTION.13
1 Scope.14
1.1 General .14
1.2 Overview .14
1.3 Specifications.15
1.4 Conformance.15
2 Normative references .15
3 Terms, definitions, abbreviations, symbols and conventions .16
3.1 Referenced terms and definitions .16
3.2 Fieldbus Application Layer type 3 – specific terms and definitions .17
3.3 Abbreviations and symbols.25
3.4 Conventions .25
4 Concepts .32
5 Data type ASE.32
6 Communication model specification.32
6.1 DP concepts.32
6.2 ASEs.52
6.3 Summary of FAL classes .430
6.4 Permitted FAL services by AREP role. 431
6.5 Conformance classes .435
6.6 Application characteristics.436
Bibliography.438

Figure 1 – Example of DP communication with a single controlling device .35
Figure 2 – Example of DP communication with several controlling devices .35
Figure 3 – Example of DP communication between field devices .36
Figure 4 – DP-slave model (modular DP-slave).38
Figure 5 – DP-slave model (compact DP-slave) .39
Figure 6 – Overview of application processes .40
Figure 7 – DP-slave model (modular DP-slave).41
Figure 8 – Application Service Elements (ASEs) .43
Figure 9 – Application Process with application Objects (APOs) .44
Figure 10 – Access to a remote APO .45
Figure 11 – Access to a remote APO for publisher/subscriber association .46
Figure 12 – Example of one AR with two AREPs.47
Figure 13 – Relation of a simple process data object to the real object .53
Figure 14 – Relation of a combined process data object to the real objects.55
Figure 15 – Sequence of an isochronous DP cycle with one DP-master (class 1).86
Figure 16 – Additional time relationships in a DP system operating in isochronous
88
mode .
Figure 17 – DP system with optimized isochronous DP cycle .89
Figure 18 – Buffered synchronized isochronous mode at the DP-master (class 1).91

---------------------- Page: 8 ----------------------

SIST EN 61158-5-3:2012
61158-5-3 © IEC:2010(E) – 3 –
Figure 19 – Enhanced synchronized isochronous mode at the DP-master (class 1) .92
Figure 20 – Input, output and PLL state machine interaction .92
Figure 21 – PLL state diagram .98
Figure 22 – OUTPUT state diagram .102
Figure 23 – INPUT state diagram.106
Figure 24 – Treatment of an alarm in the DP system. 139
Figure 25 – Load Region state diagram for erasable memory.237
Figure 26 – Load region state diagram for non erasable memory .238
Figure 27 – Function invocation state diagram .270
Figure 28 – System architecture .284
Figure 29 – Assignment of communication relationship to application relationship . 291
Figure 30 – MS0 application relationship .297
Figure 31 – Output buffer model of a DP-slave without sync functionality.298
Figure 32 – Output buffer model of a DP-slave with sync functionality .298
Figure 33 – Input buffer model of a DP-slave without freeze functionality.299
Figure 34 – Input buffer model of a DP-slave with freeze functionality.299
Figure 35 – MS1 application relationship .300
Figure 36 – MS2 application relationship .300
Figure 37 – Example of inter-network communication . 302
Figure 38 – Example without inter-network addressing. 302
Figure 39 – First example with inter-network addressing. 303
Figure 40 – Second example with inter-network addressing . 304
Figure 41 – MS3 application relationship .305
Figure 42 – MM1 application relationship .305
Figure 43 – MM2 application relationship .306
Figure 44 – Cycle time of the DP system .437

Table 1 – Requirements and features of fieldbus DP.34
Table 2 – Status values of the service primitives.51
Table 3 – Access Rights MS1 .54
Table 4 – Access Rights MS2 .54
Table 5 – Access Rights MS1 .57
Table 6 – Access Rights MS2 .57
Table 7 – SCL matching rules .58
Table 8 – Read .58
Table 9 – Write .60
Table 10 – Data transport .61
Table 11 – Format (simple input data description).65
Table 12 – Consistency (simple input data description).65
Table 13 – Format (simple output data).67
Table 14 – Consistency (simple output data).67
Table 15 – Format (extended input data) .68
Table 16 – Consistency (extended input data) .69

---------------------- Page: 9 ----------------------

SIST EN 61158-5-3:2012
– 4 – 61158-5-3 © IEC:2010(E)
Table 17 – Format (extended output data) .70
Table 18 – Consistency (extended output data) .71
Table 19 – Set Input .72
Table 20 – Read Input .72
Table 21 – Get Input .74
Table 22 – New Input.75
Table 23 – Set Output.76
Table 24 – Final.77
Table 25 – Read Output.77
Table 26 – Get Output .78
Table 27 – Clear Flag .78
Table 28 – New Flag.79
Table 29 – New Output .79
Table 30 – Clear Flag .79
Table 31 – Global Control .80
Table 32 – Clear Command .80
Table 33 – Sync Command .80
Table 34 – Freeze Command .81
Table 35 – New publisher data.81
Table 36 – Get publisher data.82
Table 37 – New Flag.82
Table 38 – SYNCH .83
Table 39 – SYNCH Delayed.83
Table 40 – DX Finished .84
Table 41 – SYNCH Event.84
Table 42 – Status .84
Table 43 – Primitives issued by the AL to the PLL state machine.94
Table 44 – Primitives issued by the user to the PLL state machine .94
Table 45 – Allowed values of Status .94
Table 46 – Primitives issued by the user to the input state machine.95
Table 47 – Primitives issued by the user to the output state machine.95
Table 48 – Primitives issued by the PLL to the output state machine .95
Table 49 – Primitives issued by the output to the PLL state machine .95
Table 50 – Primitives issued by the PLL to the input state machine .95
Table 51 – Primitives issued by the output to the input state machine.96
Table 52 – Primitives issued by the output state machine to the AL .96
Table 53 – Primitives issued by the AL to the output state machine .96
Table 54 – Primitives issued by the input state machine to the AL .96
Table 55 – Primitives issued by the AL to the input state machine .96
Table 56 – PLL state table .99
Table 57 – OUTPUT state table .103
Table 58 – INPUT state table.107
Table 59 – Identifier status .109

---------------------- Page: 10 ----------------------

SIST EN 61158-5-3:2012
61158-5-3 © IEC:2010(E) – 5 –
Table 60 – Channel type .110
Table 61 – IO type .111
Table 62 – Status type .111
Table 63 – Status specifier .112
Table 64 – Status specifier .113
Table 65 – Module status.113
Table 66 – Status specifier .114
Table 67 – Link status.114
Table 68 – Link error.115
Table 69 – Set Slave Diag .116
Table 70 – Ext Diag Flag .117
Table 71 – Get Slave Diag .119
Table 72 – Read Slave Diag .128
Table 73 – New Slave Diag.138
Table 74 – Alarm type.140
Table 75 – Add Ack.141
Table 76 – Alarm specifier .141
Table 77 – Alarm notification .142
Table 78 – Alarm Ack.143
Table 79 – Prm data type.148
Table 80 – Supported feature .158
Table 81 – Supported profile feature.158
Table 82 – Role .159
Table 83 – Check user Prm.160
Table 84 – Prm structure .161
Table 85 – MS1 Command.164
Table 86 – Check user Prm result .165
Table 87 – Status values .166
Table 88 – Check Ext user Prm.167
Table 89 – Check Ext user Prm result .170
Table 90 – Status values .171
Table 91 – Check Cfg .171
Table 92 – Check Cfg result.172
Table 93 – Status values .173
Table 94 – Set Cfg.173
Table 95 – Get Cfg .174
Table 96 – Set Slave Add .175
Table 97 – Initiate.176
Table 98 – Abort .179
Table 99 – Instance .179
Table 100 – MS0 init DP-slave.180
Table 101 – MS1 init DP-slave.180
Table 102 – MS2 init DP-slave.181

---------------------- Page: 11 ----------------------

SIST EN 61158-5-3:2012
– 6 – 61158-5-3 © IEC:2010(E)
Table 103 – DP-slave started.181
Table 104 – Alarm limit .182
Table 105 – DP-slave stopped .182
Table 106 – Reset DP-slave .183
Table 107 – DP-slave fault.183
Table 108 – Application ready DP-slave.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.