Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

This part of IEC 61000 is concerned with the limitation of voltage fluctuations and flicker impressed on the public low-voltage system. It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. This part of IEC 61000 is applicable to electrical and electronic equipment having an input current equal to or less than 16 A per phase, intended to be connected to public low-voltage distribution systems of between 220 V and 250 V line to neutral at 50 Hz, and not subject to conditional connection. Equipment which does not comply with the limits of this part of IEC 61000 when tested with the reference impedance Zref of 6.4, and which therefore cannot be declared compliant with this part, may be retested or evaluated to show conformity with IEC 61000-3-11. Part 3-11 is applicable to equipment with rated input current ≤ 75 A per phase and subject to conditional connection. The tests according to this part are type tests. Particular test conditions are given in Annex A and the test circuit is shown in Figure 1.

Elektromagnetische Verträglichkeit (EMV) - Teil 3-3: Grenzwerte - Begrenzung von Spannungsänderungen, Spannungsschwankungen und Flicker in öffentlichen Niederspannungs-Versorgungsnetzen für Geräte mit einem Bemessungsstrom <= 16 A je Leiter, die keiner Sonderanschlussbedingung unterliegen

Compatibilité électromagnétique (CEM) - Partie 3-3: Limites - Limitation des variations de tension, des fluctuations de tension et du papillotement dans les réseaux publics d'alimentation basse tension, pour les matériels ayant un courant assigné <= 16 A par phase et non soumis à un raccordement conditionnel

NEW! La CEI 61000-3-3:2013 est disponible sous forme de IEC Standards+ 61000-3-3:2013 qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.  La CEI 61000-3-3:2013 traite des limitations des fluctuations de tension et du papillotement (flicker) appliquées  sur le réseau  de distribution public basse tension. Elle spécifie les limites des variations de tension pouvant être produites par un équipement essayé dans des conditions spécifiées et formule des recommandations pour les méthodes d'évaluation. Elle s'applique aux matériels électriques et électroniques ayant un courant appelé inférieur ou égal à 16 A par phase et destinés à être raccordés à  des réseaux publics de distribution basse tension présentant une  tension nominale phase-neutre comprise entre 220 V et 250 V à 50  Hz  et non soumis  à un raccordement conditionnel. La  CEI 61000-3-3 a   le statut d'une norme de famille de produit au sein de la série  CEI 61000. Cette troisième édition annule et remplace la seconde édition parue en 2008. Cette édition constitue une révision technique qui prend en compte les changements effectués dans la CEI 61000-4-15:2010.

Elektromagnetna združljivost (EMC) - 3-3. del: Mejne vrednosti - Omejitev vrednosti kolebanja napetosti in flikerja v nizkonapetostnih napajalnih sistemih za opremo z naznačenim tokom do 16 A in ni priključena pod posebnimi pogoji (IEC 61000-3-3:2013)

Ta del standarda IEC 61000 obravnava omejitev vrednosti kolebanja napetosti in flikerja v javnih nizkonapetostnih napajalnih sistemih. Določa omejitve vrednosti kolebanja napetosti, ki jih lahko proizvede oprema, preizkušena pod določenimi pogoji, in podaja smernice za metode ocenjevanja. Ta del standarda IEC 61000 se uporablja za električno in elektronsko opremo z vhodnim tokom do vključno 16 A na fazo, ki je namenjena za povezavo z javnimi nizkonapetostnimi razdelilnimi sistemi z napetostjo med linijskim in nevtralnim vodnikom od 220 V do 250 V pri 50 Hz ter ni priključena pod posebnimi pogoji. Če opremo, ki ni v skladu z omejitvami tega dela standarda IEC 61000, preskušate z referenčno impedanco Zref 6,4 in je zato ni mogoče razglasiti za skladno s tem delom, jo lahko znova preskusite oziroma ocenite, ali je skladna s standardom IEC 61000-3-11. Del 3-11 se uporablja za opremo z nazivnim vhodnim tokom ≤ 75 A na fazo in je priključena pod posebnimi pogoji. Preskusi po tem delu so tipski preskusi. Posebni preskusni pogoji so navedeni v dodatku A, preskusni krog pa je prikazan na sliki 1.

General Information

Status
Published
Publication Date
20-Jan-2014
Current Stage
6100 - Translation of adopted SIST standards (Adopted Project)
Start Date
10-Jan-2020
Due Date
08-Jan-2021
Completion Date
22-Sep-2020

Relations

Buy Standard

Standard
EN 61000-3-3:2014
English language
38 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard – translation
EN 61000-3-3:2014
Slovenian language
37 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61000-3-3:2014
01-februar-2014
1DGRPHãþD
SIST EN 61000-3-3:2009
(OHNWURPDJQHWQD]GUXåOMLYRVW (0& GHO0HMQHYUHGQRVWL2PHMLWHY
YUHGQRVWLNROHEDQMDQDSHWRVWLLQIOLNHUMDYQL]NRQDSHWRVWQLKQDSDMDOQLKVLVWHPLK]D
RSUHPR]QD]QDþHQLPWRNRPGR$LQQLSULNOMXþHQDSRGSRVHEQLPLSRJRML ,(&

Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes,
voltage fluctuations and flicker in public low-voltage supply systems, for equipment with
rated current <= 16 A per phase and not subject to conditional connection
Compatibilité électromagnétique (CEM) - Partie 3-3: Limites - Limitation des variations de
tension, des fluctuations de tension et du papillotement dans les réseaux publics
d'alimentation basse tension, pour les matériels ayant un courant assigné <= 16 A par
phase et non soumis à un raccordement conditionnel
Ta slovenski standard je istoveten z: EN 61000-3-3:2013
ICS:
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
SIST EN 61000-3-3:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61000-3-3:2014

---------------------- Page: 2 ----------------------

SIST EN 61000-3-3:2014

EUROPEAN STANDARD
EN 61000-3-3

NORME EUROPÉENNE
August 2013
EUROPÄISCHE NORM

ICS 33.100.10 Supersedes EN 61000-3-3:2008


English version

Electromagnetic compatibility (EMC) -
Part 3-3: Limits -
Limitation of voltage changes, voltage fluctuations and flicker in public
low-voltage supply systems, for equipment with rated current ≤ 16 A per
phase and not subject to conditional connection
(IEC 61000-3-3:2013)

Compatibilité électromagnétique (CEM) -  Elektromagnetische Verträglichkeit
Partie 3-3: Limites - (EMV) -
Limitation des variations de tension, des Teil 3-3: Grenzwerte -
fluctuations de tension et du papillotement Begrenzung von Spannungsänderungen,
dans les réseaux publics d'alimentation Spannungsschwankungen und Flicker in
basse tension, pour les matériels ayant un öffentlichen Niederspannungs-
courant assigné ≤ 16 A par phase et non Versorgungsnetzen für Geräte mit einem
soumis à un raccordement conditionnel Bemessungsstrom ≤ 16 A je Leiter, die
(CEI 61000-3-3:2013) keiner Sonderanschlussbedingung
unterliegen
(IEC 61000-3-3:2013)

This European Standard was approved by CENELEC on 2013-06-18. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61000-3-3:2013 E

---------------------- Page: 3 ----------------------

SIST EN 61000-3-3:2014
EN 61000-3-3:2013 - 2 -

Foreword
The text of document 77A/809/FDIS, future edition 3 of IEC 61000-3-3, prepared by SC 77A, "EMC - Low
frequency phenomena", of IEC TC 77, "Electromagnetic compatibility" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 61000-3-3:2013.
The following dates are fixed:
(dop) 2014-03-18
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2016-06-18
• latest date by which the national
standards conflicting with the

document have to be withdrawn

This document supersedes EN 61000-3-3:2008.
EN 61000-3-3:2013 includes the following significant technical changes with respect to
EN 61000-3-3:2008:
This edition takes account of the changes made in EN 61000-4-15:2011.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Directive(s).
For the relationship with EU Directive(s) see informative Annex ZZ, which is an integral part of this
document.
Endorsement notice
The text of the International Standard IEC 61000-3-3:2013 was approved by CENELEC as a European
Standard without any modification.

---------------------- Page: 4 ----------------------

SIST EN 61000-3-3:2014
- 3 - EN 61000-3-3:2013
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC/TR 60725 - Consideration of reference impedances and - -
public supply network impedances for use in
determining disturbance characteristics of
electrical equipment having a rated current
≤ 75 A per phase


IEC 60974-1 - Arc welding equipment - EN 60974-1 -
Part 1: Welding power sources


IEC 61000-3-2 - Electromagnetic compatibility (EMC) - EN 61000-3-2 -
Part 3-2: Limits - Limits for harmonic current
emissions (equipment input current ≤ 16 A per
phase)


IEC 61000-3-11 - Electromagnetic compatibility (EMC) - EN 61000-3-11 -
Part 3-11: Limits - Limitation of voltage
changes, voltage fluctuations and flicker in
public low-voltage supply systems -
Equipment with rated current ≤ 75 A and
subject to conditional connection


IEC 61000-4-15 2010 Electromagnetic compatibility (EMC) - EN 61000-4-15 2011
+ corr. March 2012 Part 4-15: Testing and measurement
techniques - Flickermeter - Functional and
design specifications

---------------------- Page: 5 ----------------------

SIST EN 61000-3-3:2014
EN 61000-3-3:2013 - 4 -
Annex ZZ
(informative)

Coverage of Essential Requirements of EU Directives
This European Standard has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and within its scope the standard covers
protection requirements of Annex I Article 1(a) of the EU Directive 2004/108/EC and protection
requirements of Article 3.1(b) (emissions only) of the EU Directive 1999/5/EC.
Compliance with this standard provides one means of conformity with the specified essential
requirements of the Directives concerned.
WARNING: Other requirements and other EU Directives may be applicable to the products falling within
the scope of this standard.

---------------------- Page: 6 ----------------------

SIST EN 61000-3-3:2014



IEC 61000-3-3

®


Edition 3.0 2013-05




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE











Electromagnetic compatibility (EMC) –

Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker

in public low-voltage supply systems, for equipment with rated current ≤ 16 A


per phase and not subject to conditional connection



Compatibilité électromagnétique (CEM) –


Partie 3-3: Limites – Limitation des variations de tension, des fluctuations de

tension et du papillotement dans les réseaux publics d'alimentation basse

tension, pour les matériels ayant un courant assigné ≤ 16 A par phase et non

soumis à un raccordement conditionnel









INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX V


ICS 33.100.10 ISBN 978-2-83220-781-9



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 61000-3-3:2014
– 2 – 61000-3-3 © IEC:2013
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
4 Assessment of voltage changes, voltage fluctuations and flicker . 10
4.1 Assessment of a relative voltage change, d(t) . 10
4.2 Assessment of the short-term flicker value, P . 10
st
4.2.1 General . 10
4.2.2 Flickermeter . 11
4.2.3 Simulation method . 11
4.2.4 Analytical method . 11
4.2.5 Use of P = 1 curve . 12

st
4.3 Assessment of long-term flicker value, P . 12
lt
5 Limits . 12
6 Test conditions . 13
6.1 General . 13
6.2 Measurement uncertainty . 14
6.3 Test supply voltage . 14
6.4 Reference impedance . 14
6.5 Observation period . 14
6.6 General test conditions . 15
Annex A (normative) Application of limits and type test conditions for specific
equipment . 19
Annex B (normative) Test conditions and procedures for measuring d voltage
max
changes caused by manual switching . 27
Annex C (informative) Determination of steady state voltage and voltage change
characteristics, as defined in IEC 61000-4-15:2010 . 28
Annex D (informative) Input relative voltage fluctuation ∆V/V for P = 1,0 at output
st
[IEC/TR 61000-3-7:2008] . 33
Bibliography . 34

Figure 1 – Reference network for single-phase and three-phase supplies derived from
a three-phase, four-wire supply . 16
Figure 2 – Curve for P = 1 for rectangular equidistant voltage changes . 17
st
Figure 3 – Shape factors F for double-step and ramp-voltage characteristics . 17
Figure 4 – Shape factors F for rectangular and triangular voltage characteristics . 18
Figure 5 – Shape factor F for motor-start voltage characteristics having various front
times. 18
Figure C.1 – Evaluation of U (t) . 32
hp

Table 1 – Assessment method . 11
Table A.1 – Test conditions for hotplates . 19
Table A.2 – Electrode parameters . 24
Table A.3 – Frequency factor R related to repetition rate "r" . 25

---------------------- Page: 8 ----------------------

SIST EN 61000-3-3:2014
61000-3-3 © IEC:2013 – 3 –
Table C.1 – Test specification for d – d – t (from Table 12 of
c max d(t) > 3,3 %
IEC 61000-4-15: 2010). 31
Table C.2 – Test specification for d – d – t (from Table 13 of
c max d(t) > 3,3 %

IEC 61000-4-15: 2010). 31
Table D.1 – Input relative voltage fluctuation ∆V/V for P = 1,0 at output . 33
st

---------------------- Page: 9 ----------------------

SIST EN 61000-3-3:2014
– 4 – 61000-3-3 © IEC:2013
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

ELECTROMAGNETIC COMPATIBILITY (EMC) –

Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and
flicker in public low-voltage supply systems, for equipment with rated
current ≤ 16 A per phase and not subject to conditional connection

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61000-3-3 has been prepared by subcommittee 77A: EMC – Low
frequency phenomena, of IEC technical committee 77: Electromagnetic compatibility.
This standard forms part 3-3 of IEC 61000 series of standards. It has the status of a product
family standard.
This third edition cancels and replaces the second edition published in 2008. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) This edition takes account of the changes made in IEC 61000-4-15:2010.

---------------------- Page: 10 ----------------------

SIST EN 61000-3-3:2014
61000-3-3 © IEC:2013 – 5 –
The text of this standard is based on the following documents:
FDIS Report on voting
77A/809/FDIS 77A/816/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 61000 series, published under the general title Electromagnetic
compatibility (EMC), can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 11 ----------------------

SIST EN 61000-3-3:2014
– 6 – 61000-3-3 © IEC:2013
INTRODUCTION
IEC 61000 is published in separate parts according to the following structure:
Part 1: General
General considerations (introduction, fundamental principles)
Definitions, terminology
Part 2: Environment
Description of the environment
Classification of the environment
Compatibility levels
Part 3: Limits
Emission limits
Immunity limits (in so far as they do not fall under the responsibility of product
committees)
Part 4: Testing and measurement techniques
Measurement techniques
Testing techniques
Part 5: Installation and mitigation guidelines
Installation guidelines
Mitigation methods and devices
Part 9: Miscellaneous
Each part is further subdivided into sections which are to be published either as International
Standards or as Technical Reports.
These standards and reports will be published in chronological order and numbered
accordingly.

---------------------- Page: 12 ----------------------

SIST EN 61000-3-3:2014
61000-3-3 © IEC:2013 – 7 –
ELECTROMAGNETIC COMPATIBILITY (EMC) –

Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and
flicker in public low-voltage supply systems, for equipment with rated
current ≤ 16 A per phase and not subject to conditional connection



1 Scope
This part of IEC 61000 is concerned with the limitation of voltage fluctuations and flicker
impressed on the public low-voltage system.
It specifies limits of voltage changes which may be produced by an equipment tested under
specified conditions and gives guidance on methods of assessment.
This part of IEC 61000 is applicable to electrical and electronic equipment having an input
current equal to or less than 16 A per phase, intended to be connected to public low-voltage
distribution systems of between 220 V and 250 V line to neutral at 50 Hz, and not subject to
conditional connection.
Equipment which does not comply with the limits of this part of IEC 61000 when tested with
the reference impedance Z of 6.4, and which therefore cannot be declared compliant with
ref
this part, may be retested or evaluated to show conformity with IEC 61000-3-11. Part 3-11 is
applicable to equipment with rated input current ≤ 75 A per phase and subject to conditional
connection.
The tests according to this part are type tests. Particular test conditions are given in Annex A
and the test circuit is shown in Figure 1.
NOTE 1 The limits in this standard relate to the voltage changes experienced by consumers connected at the
interface between the public supply low-voltage network and the equipment user’s installation. Consequently, if the
actual impedance of the supply at the supply terminals of equipment connected within the equipment user’s
installation exceeds the test impedance, it is possible that supply disturbance exceeding the limits could occur.
NOTE 2 The limits in this standard are based mainly on the subjective severity of flicker imposed on the light from
230 V 60 W coiled-coil filament lamps by fluctuations of the supply voltage. For systems with nominal voltage less
than 220 V line to neutral and/or frequency of 60 Hz, the limits and reference circuit values are under
consideration.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC/TR 60725, Consideration of reference impedances and public supply impedances for use
in determining disturbance characteristics of electrical equipment having a rated current
≤ 75 A per phase
IEC 60974-1, Arc welding equipment – Part 1: Welding power sources
IEC 61000-3-2, Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic
current emissions (equipment input current ≤ 16 A per phase)

---------------------- Page: 13 ----------------------

SIST EN 61000-3-3:2014
– 8 – 61000-3-3 © IEC:2013
IEC 61000-3-11, Electromagnetic compatibility (EMC) – Part 3-11: Limits – Limitation of
voltage changes, voltage fluctuations and flicker in public low-voltage supply systems –
Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-4-15:2010, Electromagnetic compatibility (EMC) – Part 4-15: Testing and
measurement techniques – Flickermeter – Functional and design specifications
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
flicker
impression of unsteadiness of visual sensation induced by a light stimulus whose luminance
or spectral distribution fluctuates with time
[SOURCE: IEC 60050-161:1990, 161-08-13]
3.2
voltage change characteristic
d(t)
time function of the relative r.m.s. voltage change evaluated as a single value for each
successive half period between zero-crossings of the source voltage, except during time
intervals in which the voltage is in a steady-state condition for at least 1 s
Note 1 to entry: For detailed information about the evaluation of a voltage change characteristic and the definition
of a steady state condition see Annex C and IEC 61000-4-15:2010.
3.3
d
c
maximum steady state voltage change during an observation period
Note 1 to entry: For detailed information about the calculation of d see Annex C and IEC 61000-4-15:2010.
c
3.4
d
max
maximum absolute voltage change during an observation period
Note 1 to entry: For detailed information about the calculation of d see Annex C and IEC 61000-4-15:2010.
max
3.5
T
max
maximum time duration during the observation period that the voltage deviation d(t) exceeds
the limit for d
c
Note 1 to entry: During a voltage change characteristic the time duration T is accumulated until a new steady
max
state condition is established.
Note 2 to entry: The T limit evaluation in this standard is generally intended to evaluate the inrush current
max
pattern of the equipment under test. Thus, as soon as a new steady state condition is established, the T
max
evaluation is ended. When a new voltage change occurs that exceeds the limit for d , a new T evaluation is
c max
started. The maximum duration that d(t) exceeds the limit for d for any of the individual T evaluations during the
c max
observation period, is used for the comparison against the T limit, and is reported for the test.
max
3.6
nominal test voltage
U
n
nominal test voltage used to calculate percentages for the various directly measured
parameters

---------------------- Page: 14 ----------------------

SIST EN 61000-3-3:2014
61000-3-3 © IEC:2013 – 9 –
Note 1 to entry: If no steady state condition is achieved during the observation period, U is used for the
n
calculation of d and T .
max max
Note 2 to entry: U is not necessarily equal to the nominal voltage of the public supply.
n
3.7
P
st
short-term flicker severity
Note 1 to entry: If not specified differently, the P evaluation time is 10 minutes. For the purpose of power quality
st
surveys and studies, other time intervals may be used, and have to be defined in the index. For example a 1
minute interval should be written as P
st,1min.
3.8
P
lt
long-term flicker severity
N
3
P

st,i
3
i =1
P =
lt
N
where P (i = 1, 2, 3, .) are consecutive readings of the short-term severity P
st
st,i
Note 1 to entry: Unless otherwise specified, P is calculated over discrete T periods. Each time a T period
lt long long
has expired, a new P calculation is started.
lt
3.9
flickermeter
instrument designed to measure any quantity representative of flicker
Note 1 to entry: Measurements are normally P and P and may also include the directly measured parameters
st lt
specified in 3.2 to 3.5.
[SOURCE: IEC 60050-161:1990, 161-08-14]
3.10
flicker impression time
t
f
value with a time dimension which describes the flicker impression of a voltage change
characteristic
3.11
shape factor
F
value derived from the type of voltage fluctuation, such as a step, double step, or ramp
pattern
Note 1 to entry: The shape factor is mainly needed when the analytical method is used to calculate P .
st
3.12
interface point
interface between a public supply network and a user’s installation
3.13
conditional connection
connection of equipment requiring the user’s supply at the interface point to have an
impedance lower than the reference impedance Z in order that the equipment emissions
ref
comply with the limits in this part
Note 1 to entry: Meeting the voltage change limits may not be the only condition for connection; emission limits
for other phenomena such as harmonics, may also have to be satisfied.

---------------------- Page: 15 ----------------------

SIST EN 61000-3-3:2014
– 10 – 61000-3-3 © IEC:2013
4 Assessment of voltage changes, voltage fluctuations and flicker
4.1 Assessment of a relative voltage change, d(t)
The basis for flicker evaluation is the voltage change characteristic at the terminals of the
(t) of any two successive values of the
equipment under test, that is the difference ∆ U
hp
phase-to-neutral voltages U (t ) and U (t ):
hp 1 hp 2
∆ U (t) = U (t ) – U (t ) (1)
hp hp 1 hp 2
NOTE 1 See Annex C for relevant definitions that are taken from IEC 6
...

ba

SLOVENSKI SIST EN 61000-3-3


STANDARD    februar 2014













Elektromagnetna združljivost (EMC) – 3-3. del: Mejne vrednosti –
Omejitev vrednosti kolebanja napetosti in flikerja v nizkonapetostnih
napajalnih sistemih za opremo z naznačenim tokom do 16 A in ni
priključena pod posebnimi pogoji (IEC 61000-3-3:2013)

Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage
changes, voltage fluctuations and flicker in public low-voltage supply systems,
for equipment with rated current ≤ 16 A per phase and not subject to conditional
connection (IEC 61000-3-3:2013)

Compatibilité électromagnétique (CEM) – Partie 3-3: Limites – Limitation des
variations de tension, des fluctuations de tension et du papillotement dans les
réseaux publics d'alimentation basse tension, pour les matériels ayant un
courant assigné ≤ 16 A par phase et non soumis à un raccordement conditionnel
(CEI 61000-3-3:2013)

Elektromagnetische Verträglichkeit (EMV) – Teil 3-3: Grenzwerte –
Begrenzung von Spannungsänderungen, Spannungsschwankungen und Flicker
in öffentlichen Niederspannungs- Versorgungsnetzen für Geräte mit einem
Bemessungsstrom ≤ 16 A je Leiter, die keiner Sonderanschlussbedingung
unterliegen (IEC 61000-3-3:2013)








Referenčna oznaka
ICS 33.100.01 SIST EN 61000-3-3:2014 (sl)

Nadaljevanje na straneh II do III in od 1 do 35

© 2020-10. Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 61000-3-3 : 2014
NACIONALNI UVOD

Standard SIST EN 61000-3-3 (sl), Elektromagnetna združljivost (EMC) – 3-3. del: Mejne vrednosti –
Omejitev vrednosti kolebanja napetosti in flikerja v nizkonapetostnih napajalnih sistemih za opremo z
naznačenim tokom do 16 A in ni priključena pod posebnimi pogoji (IEC 61000-3-3:2013), 2014, ima
status slovenskega standarda in je istoveten evropskemu standardu EN 61000-3-3 (en),
Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage
fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per
phase and not subject to conditional connection, 2013.

Ta standard nadomešča SIST EN 61000-3-3:2009.

NACIONALNI PREDGOVOR

Evropski standard EN 61000-3-3:2013 je pripravil tehnični odbor Evropske organizacije za
standardizacijo na področju elektrotehnike CENELEC CLC/TC 210 Elektromagnetna združljivost
(EMC). Slovenski standard SIST EN 61000-3-3:2014 je prevod evropskega standarda EN 61000-3-
3:2013. V primeru spora glede besedila slovenskega prevoda v tem standardu je odločilen izvirni
evropski standard v angleškem jeziku. Slovensko izdajo standarda je pripravil tehnični odbor SIST/TC
EMC Elektromagnetna združljivost.

Odločitev za privzem tega standarda je v februarju 2014 sprejel tehnični odbor SIST/TC EMC
Elektromagnetna združljivost.

ZVEZE S STANDARDI

S privzemom tega evropskega standarda veljajo za omejeni namen referenčnih standardov vsi
standardi, navedeni v izvirniku, razen tistih, ki so že sprejeti v nacionalno standardizacijo:
SIST-TP IEC/TR 60725 Ugotovitve o referenčnih impedancah in impedancah javnega napajalnega
omrežja za določanje značilnosti motenj električne opreme z nazivnim
faznim tokom do vključno 75 A
SIST EN 60974-1 Naprave za obločno varjenje – 1. del: Viri varilnega toka
SIST EN IEC 61000-3-2 Elektromagnetna združljivost (EMC) – 3-2. del: Mejne vrednosti – Mejne
vrednosti za oddajanje harmonskih tokov (vhodni tok opreme do vključno
16 A na fazo)
SIST EN IEC 61000-3-11 Elektromagnetna združljivost (EMC) – 3-11. del: Mejne vrednosti –
Omejitev vrednosti kolebanja napetosti in flikerja v nizkonapetostnih
napajalnih sistemih – Oprema z naznačenim tokom ≤ 75 A, priključena pod
posebnimi pogoji
SIST EN 61000-4-15:2011 Elektromagnetna združljivost (EMC) – 4-15. del: Preskusne in merilne
tehnike – Flikermeter – Specifikacije funkcij in zasnove

OSNOVA ZA IZDAJO STANDARDA

– EN 61000-3-3:2013

PREDHODNA IZDAJA

– SIST EN 61000-3-3:2009


II

---------------------- Page: 2 ----------------------
SIST EN 61000-3-3 : 2014

OPOMBE

– Povsod, kjer se v besedilu standarda uporablja izraz "evropski standard" ali "mednarodni standard",
v SIST EN 61000-3-3:2014 to pomeni "slovenski standard".

– Nacionalni uvod in nacionalni predgovor nista sestavni del standarda.

– Ta nacionalni dokument je istoveten EN 61000-3-3:2013 in je objavljen z dovoljenjem

CEN-CENELEC
Upravni center
Avenue Marnix 17
B-1000 Bruselj


This national document is identical with EN 61000-3-3:2013 and is published with the permission
of

CEN-CENELEC
Management Centre
Avenue Marnix 17
B -1000 Brussels




































III

---------------------- Page: 3 ----------------------
SIST EN 61000-3-3 : 2014






















(prazna stran)





IV

---------------------- Page: 4 ----------------------
EVROPSKI STANDARD            EN 61000-3-3
EUROPEAN STANDARD

NORME EUROPÉENNE
                  avgust 2013
EUROPÄISCHE NORM

ICS 33.100.10 Nadomešča EN 61000-3-3:2008





Slovenska izdaja

Elektromagnetna združljivost (EMC) – 3-3. del: Mejne vrednosti –
Omejitev vrednosti kolebanja napetosti in flikerja v nizkonapetostnih
napajalnih sistemih za opremo z naznačenim tokom do 16 A in ni priključena
pod posebnimi pogoji (IEC 61000-3-3:2013)

Electromagnetic compatibility Compatibilité électromagnétique Elektromagnetische Verträglichkeit
(EMC) – Part 3-3: Limits - (CEM) – Partie 3-3: Limites - (EMV) – Teil 3-3: Grenzwerte –
Limitation of voltage changes, Limitation des variations de Begrenzung von Spannungs-
voltage fluctuations and flicker in tension, des fluctuations de änderungen, Spannungs-
public low-voltage supply systems, tension et du papillotement dans schwankungen und Flicker in
for equipment with rated current <=
les réseaux publics d'alimentation öffentlichen Nieder-spannungs-
16 A per phase and not subject to basse tension, pour les matériels Versorgungsnetzen für Geräte mit
conditional connection ayant un courant assigné <= 16 A einem Bemessungsstrom ≤ 16 A je
par phase et non soumis à un Leiter, die keiner
raccordement conditionnel Sonderanschluss-bedingung
unterliegen (IEC 61000-3-3:2013)


Ta evropski standard je CENELEC sprejel 18. junija 2013. Člani CENELEC morajo izpolnjevati notranje
predpise CEN/CENELEC, s katerimi so predpisani pogoji za privzem tega evropskega standarda na
nacionalno raven brez kakršnihkoli sprememb.

Najnovejši seznami teh nacionalnih standardov z njihovimi bibliografskimi podatki se na zahtevo lahko
dobijo pri Upravnem centru CEN-CENELEC ali kateremkoli članu CENELEC.

Ta evropski standard obstaja v treh uradnih izdajah (angleški, francoski in nemški). Izdaje v drugih
jezikih, ki jih člani CENELEC na lastno odgovornost prevedejo in izdajo ter prijavijo pri Upravnem centru
CEN-CENELEC, veljajo kot uradne izdaje.

Člani CENELEC so nacionalni elektrotehniški komiteji Avstrije, Belgije, Bolgarije, Cipra, Češke
republike, Danske, Estonije, Finske, Francije, Hrvaške, Grčije, Irske, Islandije, Italije, Latvije, Litve,
Luksemburga, Malte, Nekdanje jugoslovanske republike Makedonije, Madžarske, Nemčije,
Nizozemske, Norveške, Poljske, Portugalske, Romunije, Slovaške, Slovenije, Španije, Švedske, Švice
in Združenega kraljestva.



CENELEC
Evropski komite za standardizacijo v elektrotehniki
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Upravni center CEN-CENELEC: Avenue Marnix 17, B-1000 Bruselj

© 2013 CENELEC Lastnice avtorskih pravic so vse države članice CENELEC.         Ref. oznaka EN 61000-3-3:2013 E

---------------------- Page: 5 ----------------------
SIST EN 61000-3-3 : 2014
Evropski predgovor

Besedilo dokumenta 77A/809/FDIS, prihodnje 3. izdaje IEC 61000-3-3, ki ga je pripravil pododbor SC
77A "Nizkofrekvenčni pojavi" pri tehničnem odboru IEC/TC 77 "Elektromagnetna združljivost", je bilo
predloženo v vzporedno glasovanje IEC-CENELEC in ga je CENELEC sprejel kot EN 61000-3-3:2013.

Določena sta bila naslednja datuma:

 zadnji datum, do katerega mora EN dobiti status (dop) 2014-03-18
nacionalnega standarda bodisi z objavo istovetnega
besedila ali z razglasitvijo
(dow) 2016-06-18
 zadnji datum, ko je treba razveljaviti nacionalne
standarde, ki so z EN v nasprotju

Ta dokument nadomešča EN 61000-3-3:2008.

Standard EN 61000-3-3:2013 vključuje naslednje pomembne tehnične spremembe glede na EN 61000-
3-3:2008:

Ta izdaja upošteva spremembe, narejene v EN 61000-4-15:2011.

Opozoriti je treba na možnost, da bi lahko bil kateri od elementov tega dokumenta predmet patentnih
pravic. CENELEC ni odgovoren za identificiranje nobene od teh patentnih pravic.
Ta dokument je bil pripravljen v okviru mandata, ki sta ga Evropska komisija in Evropsko združenje za
prosto trgovino dala CENELEC, in podpira bistvene zahteve direktive (direktiv) EU.

Za zveze z direktivo (direktivami) EU glej informativni dodatek ZZ, ki je sestavni del tega dokumenta.



Razglasitvena objava

Besedilo mednarodnega standarda IEC 61000-3-3:2013 je CENELEC odobril kot evropski standard
brez kakršnihkoli sprememb.


2

---------------------- Page: 6 ----------------------
SIST EN 61000-3-3 : 2014
Dodatek ZA
(normativni)




Normativna sklicevanja na mednarodne publikacije z njihovimi ustreznimi
evropskimi publikacijami


Pri uporabi tega dokumenta so nujno potrebni naslednji referenčni dokumenti. Pri datiranih sklicevanjih
velja le navedena izdaja dokumenta. Pri nedatiranih sklicevanjih se uporablja zadnja izdaja publikacije
(vključno z dopolnili).

OPOMBA: Kadar je neka mednarodna publikacija spremenjena s skupnimi spremembami, označenimi z (mod), je treba
uporabiti ustrezni EN/HD

Publikacija Leto Naslov EN/HD Leto
IEC/TR 60725 - Ugotovitve o referenčnih impedancah in - -
impedancah javnega napajalnega
omrežja za določanje značilnosti motenj
električne opreme z nazivnim faznim
tokom do vključno 75 A
IEC 60974-1 - Naprave za obločno varjenje – EN 60974-1 -
1. del: Viri varilnega toka
IEC 61000-3-2 - Elektromagnetna združljivost (EMC) – EN 61000-3-2 -
3-2. del: Mejne vrednosti – Mejne vrednosti
za oddajanje harmonskih tokov (vhodni tok
opreme do vključno 16 A na fazo)
IEC 61000-3-11 - Elektromagnetna združljivost (EMC) – EN 61000-3-11 -
3-11. del: Mejne vrednosti – Omejitev
vrednosti kolebanja napetosti in flikerja v
nizkonapetostnih napajalnih sistemih –
Oprema z naznačenim tokom ≤ 75 A,
priključena pod posebnimi pogoji
IEC 61000-4-15 2010 Elektromagnetna združljivost (EMC) – EN 61000-4-15 2011
4-15. del: Preskusne in merilne tehnike –
+ popravek marec 2012 EN 61000-3-3 2013
Flikermeter – Specifikacije funkcij in
zasnove


3

---------------------- Page: 7 ----------------------
SIST EN 61000-3-3 : 2014
Dodatek ZZ
(normativni)




Vključitev bistvenih zahtev direktiv EU


Ta evropski standard je bil pripravljen v okviru mandata, ki sta ga Evropska komisija in Evropsko
združenje za prosto trgovino dala CENELEC, in v obsegu svojega področja uporabe vključuje zaščitne
zahteve Priloge I, člena 1(a) Direktive 2004/108/ES in bistvene zahteve člena 3.1(b) (samo oddajanje)
Direktive 1999/5/ES.

Skladnost s tem standardom zagotavlja domnevo o skladnosti z določenimi bistvenimi zahtevami
zadevnih direktiv.

OPOMBA: Za proizvode, ki spadajo v področje uporabe tega standarda, se lahko uporabljajo druge zahteve in druge
direktive EU.


4

---------------------- Page: 8 ----------------------
SIST EN 61000-3-3 : 2014
VSEBINA Stran

Predgovor . 7
Uvod . 9
1 Področje uporabe . 10
2 Zveze s standardi . 10
3 Izrazi in definicije . 11
4 Ocena napetostnih sprememb, kolebanja napetosti in flikerja . 13
4.1 Ocena relativne napetostne spremembe, d(t) . 13
4.2 Ocena kratkotrajne vrednosti flikerja, P . 13
st
4.2.1 Splošno . 13
4.2.2 Flikermeter . 14
4.2.3 Simulacijska metoda . 14
4.2.4 Analitična metoda . 14
4.2.5 Uporaba krivulje P = 1 . 15
st
4.3 Ocena dolgotrajne vrednosti flikerja, P . 15
lt
5 Mejne vrednosti . 15
6 Preskusni pogoji . 16
6.1 Splošno . 16
6.2 Merilna negotovost . 17
6.3 Preskusna napajalna napetost . 17
6.4 Referenčna impedanca . 17
6.5 Opazovalno obdobje . 18
6.6 Splošni preskusni pogoji . 18
Dodatek A (normativni): Uporaba mejnih vrednosti in pogoji za preskus tipa določene opreme . 22
Dodatek B (normativni): Preskusni pogoji in postopki za merjenje sprememb napetosti d ,
max
ki jih povzroča ročno preklapljanje . 29
Dodatek C (informativni): Ugotavljanje napetosti v ustaljenem stanju in karakteristike napetostnih
sprememb, kot so opredeljene v IEC 61000-4-15:2010 . 30
Dodatek D (informativni): Vhodno relativno kolebanje napetosti ΔV/V za P = 1,0 na izhodu
st
[IEC / TR 61000-3-7:2008] . 34
Literatura . 35

Slika 1: Referenčno omrežje za enofazna in trifazna napajanja, izvedeno iz trifaznega
štirižičnega napajanja . 19
Slika 2: Krivulja za P = 1 za pravokotne enako oddaljene napetostne spremembe . 20
st
Slika 3: Faktorji oblike F za dvojnostopničaste napetostne karakteristike in
napetostne karakteristike po rampi . 20
Slika 4: Faktorji oblike F za pravokotne in trikotne napetostne karakteristike . 21
Slika 5: Faktor oblike F za karakteristiko zagona motorja z različnimi časi čela . 21
Slika C.1: Ovrednotenje U (t) . 33
hp

5

---------------------- Page: 9 ----------------------
SIST EN 61000-3-3 : 2014
Preglednica 1: Ocenjevalna metoda . 14
Preglednica A.1: Preskusni pogoji za kuhalne plošče . 22
Preglednica A.2: Parametri elektrod . 27
Preglednica A.3: Faktor frekvence R v povezavi s frekvenco ponavljanja "r" . 28
Preglednica C.1: Specifikacija preskusa za d – d – t > 3,3 %
c max d(t)

(iz preglednice 12 IEC 61000-4-15:2010) . 32
Preglednica C.2: Specifikacija preskusa za d – d – t > 3,3 %
c max d(t)

(iz preglednice 13 IEC 61000-4-15:2010) . 33
Preglednica D.1: Vhodna relativna kolebanja napetosti ∆V/V za P = 1,0 na izhodu. 34
st


6

---------------------- Page: 10 ----------------------
SIST EN 61000-3-3 : 2014
MEDNARODNA ELEKTROTEHNIŠKA KOMISIJA

ELEKTROMAGNETNA ZDRUŽLJIVOST (EMC) –

3-3. del: Mejne vrednosti – Omejitev napetostnih sprememb, kolebanja napetosti in
flikerja v javnih nizkonapetostnih napajalnih sistemih za opremo z naznačenim tokom
do vključno 16 A in brez pogojne priključitve

Predgovor

1) IEC (Mednarodna elektrotehniška komisija) je svetovna organizacija za standardizacijo, ki združuje vse nacionalne
elektrotehnične komiteje (nacionalni komiteji IEC). Cilj IEC je pospeševati mednarodno sodelovanje v vseh vprašanjih
standardizacije s področja elektrotehnike in elektronike. V ta namen poleg drugih aktivnosti izdaja mednarodne standarde,
tehnične specifikacije, tehnična poročila, javnosti dostopne specifikacije (PAS) in vodila (v nadaljevanju: publikacije IEC). Za
njihovo pripravo so odgovorni tehnični odbori. Vsak nacionalni komite IEC, ki ga zanima obravnavana tema, lahko sodeluje v
tem pripravljalnem delu. Prav tako lahko v pripravi sodelujejo mednarodne organizacije ter vladne in nevladne ustanove, ki
so povezane z IEC. IEC deluje v tesni povezavi z mednarodno organizacijo za standardizacijo ISO skladno s pogoji,
določenimi v soglasju med obema organizacijama.
2) Uradne odločitve ali sporazumi IEC o tehničnih vprašanjih, pripravljeni v tehničnih odborih, v katerih so prisotni vsi nacionalni
komiteji, ki jih tema zanima, izražajo, kolikor je mogoče, mednarodno soglasje o obravnavani temi.
3) Publikacije IEC imajo obliko priporočil za njihovo uporabo na mednarodni ravni in jih kot takšne sprejmejo nacionalni komiteji
IEC. Čeprav IEC skuša na vse primerne načine zagotavljati točnost tehničnih vsebin v publikacijah IEC, IEC ne more biti
odgovoren za način, kako se določila uporabljajo, ter za morebitne napačne razlage končnih uporabnikov.
4) Da bi pospeševali mednarodno poenotenje, so se nacionalni komiteji IEC zavezali, da bodo v svojih nacionalnih in regionalnih
standardih čim pregledneje uporabljali mednarodne standarde. Vsako odstopanje med standardom IEC in ustreznim
nacionalnim ali regionalnim standardom je treba v slednjem jasno označiti.
5) IEC ni določil nobenega postopka označevanja, ki bi kazal na njegovo potrditev, in ne more biti odgovoren za katero koli
opremo, ki bi bila deklarirana kot skladna z eno od njegovih publikacij.
6) Vsi uporabniki naj bi si zagotovili zadnjo izdajo teh publikacij.
7) IEC ali njegovi direktorji, zaposleni, uslužbenci ali agenti, vključno s samostojnimi strokovnjaki ter člani tehničnih odborov in
nacionalnih komitejev IEC, ne prevzemajo nobene odgovornosti za kakršnokoli osebno poškodbo, škodo na premoženju ali
katerokoli drugo škodo kakršnekoli vrste, bodisi posredne ali neposredne, ali za stroške (vključno z zakonitim lastništvom) in
izdatke, povezane s publikacijo, njeno uporabo ali zanašanjem na to publikacijo IEC ali katerokoli drugo publikacijo IEC.
8) Pozornost je treba posvetiti normativnim virom, na katere se sklicuje ta publikacija. Uporaba navedenih publikacij je nujna za
pravilno uporabo te publikacije.
9) Opozoriti je treba na možnost, da bi lahko bil kateri od elementov tega mednarodnega standarda predmet patentnih pravic.
IEC ni odgovoren za identificiranje nobene od teh patentnih pravic.
Mednarodni standard IEC 61000-3-3 je pripravil pododbor SC 77A EMC – Nizkofrekvenčni pojavi pri
tehničnem odboru IEC/TC 77 Elektromagnetna združljivost.

Ta standard predstavlja 3-3. del iz skupine standardov IEC 61000. Ima status standarda za proizvod.

Ta tretja izdaja razveljavlja in nadomešča drugo izdajo, objavljeno leta 2008. Ta izdaja predstavlja
tehnično revizijo.

Ta izdaja vključuje naslednje pomembne tehnične spremembe glede na prejšnjo izdajo:

a) Ta izdaja upošteva spremembe, narejene v EN 61000-4-15:2010.

Besedilo tega standarda je osnovano na naslednjih dokumentih:

FDIS Poročilo o glasovanju
77A/809/FDIS 77A/816/RVD

Vse informacije o glasovanju za potrditev tega standarda lahko najdete v poročilu o glasovanju,
navedenem v preglednici zgoraj.
7

---------------------- Page: 11 ----------------------
SIST EN 61000-3-3 : 2014
Ta publikacija je bila pripravljena v skladu z 2. delom Direktiv ISO/IEC.
Seznam vseh delov skupine standardov IEC 61000 s skupnim naslovom Elektromagnetna združljivost
(EMC) je mogoče najti na spletni strani IEC.

Tehnični odbor je sklenil, da bo vsebina tega standarda ostala nespremenjena do datuma, določenega
za zaključek periodičnega pregleda, ki je določen na spletni strani IEC "http://webstore.iec.ch" pri
podatkih za to publikacijo. Po tem datumu bo publikacija:
– ponovno potrjena,
– razveljavljena,
– zamenjana z novo izdajo ali
– dopolnjena.


8

---------------------- Page: 12 ----------------------
SIST EN 61000-3-3 : 2014
Uvod

IEC 61000 je objavljen v ločenih delih ustrezno z naslednjo strukturo:

1. del: Splošno

Splošni vidiki (uvod, temeljna načela)

Definicije, terminologija

2. del: Okolje

Opis okolja

Klasifikacija okolja

Ravni združljivosti

3. del: Mejne vrednosti

Mejne vrednosti oddajanja

Mejne vrednosti odpornosti
(dokler niso uvrščene v delovno področje odborov za proizvode)

4. del: Preskusne in merilne tehnike

Merilne tehnike

Preskusne tehnike

5. del: Navodila za namestitev in ublažitev

Navodila za namestitev

Metode in naprave za blaženje

6. del: Osnovni standardi

9. del: Razno

Vsak del je v nadaljevanju razdeljen v več delov, ki so objavljeni kot mednarodni standardi ali kot
tehnična poročila.

Ti standardi in poročila bodo objavljeni v kronološkem vrstnem redu in ustrezno oštevilčeni.


9

---------------------- Page: 13 ----------------------
SIST EN 61000-3-3 : 2014
Elektromagnetna združljivost (EMC) – 3-3. del: Mejne vrednosti – Omejitev napetostnih
sprememb, kolebanja napetosti in flikerja v javnih nizkonapetostnih napajalnih
sistemih za opremo z naznačenim tokom do vključno 16 A in brez pogojne priključitve

1 Področje uporabe

Ta del IEC 61000 obravnava omejevanje napetostnih sprememb in flikerja, ki so injicirani v javni
nizkonapetostni sistem napajanja.

Določa mejne vrednosti napetostnih sprememb, ki jih lahko proizvede oprema, preskušena v posebnih
pogojih, in daje napotek o metodah ocenjevanja.

Ta del IEC 61000 se uporablja za električno in elektronsko opremo z vhodnim tokom, enakim ali manjšim
od 16 A fazno, ki je namenjena priključitvi v javne nizkonapetostne distribucijske sisteme z napetostnim
območjem med 220 V in 250 V med linijskim in nevtralnim vodnikom pri 50 Hz in ni predmet pogojne
priključitve.

Oprema, ki pri preskušanju z referenčno impedanco Z iz 6.4 ni v skladu z mejnimi vrednostmi tega
ref
dela IEC 61000 in je zato ni mogoče razglasiti za skladno s tem delom, se lahko ponovno preskusi ali
ovrednoti, da se prikaže skladnost z IEC 61000-3-11. Del 3-11 se uporablja za opremo z naznačenim
vhodnim tokom do vključno 75 A na fazo in je predmet pogojne priključitve.

Preskusi po tem delu so preskusi tipa. Posebni preskusni pogoji so navedeni v dodatku A, preskusni
tokokrog pa je prikazan na sliki 1.

OPOMBA 1: Mejne vrednosti v tem standardu se nanašajo na spremembe napetosti, ki jih doživljajo uporabniki, priključeni na
točki vmesnika med javnim nizkonapetostnim omrežjem in inštalacijo uporabnika opreme. Če dejanska
impedanca napajalnega omrežja na napajalnih priključkih opreme, priključene znotraj inštalacije uporabnika
opreme, presega preskusno impedanco, je posledično mogoče, da pride v napajanju do motenj, ki presegajo
mejne vrednosti.

OPOMBA 2: Mejne vrednosti v tem standardu temeljijo predvsem na subjektivni jakosti flikerja, ki se superponira na svetlobo
žarnic s spiralno žarilno nitko 230 V 60 W s kolebanjem napajalne napetosti. Pri sistemih z nazivno napetostjo
pod 220 V med linijskim in nevtralnim vodnikom in/ali s frekvenco 60 Hz so mejne vrednosti in vrednosti
referenčnega tokokroga še v obravnavi.

2 Zveze s standardi

Za uporabo tega standarda so, v celoti ali delno, nujno potrebni spodaj navedeni referenčni dokumenti.
Pri datiranih sklicevanjih se uporablja le navedena izdaja. Pri nedatiranih sklicevanjih se uporablja
zadnja izdaja publikacije (vključno z dopolnili).

IEC/TR 60725 Ugotovitve o referenčnih impedancah in impedancah javnega napajalnega
omrežja za določanje značilnosti motenj električne opreme z nazivnim faznim
tokom do vključno 75 A

IEC 60974-1 Naprave za obločno varjenje – 1. del: Viri varilnega toka

IEC 61000-3-2 Elektromagnetna združljivost (EMC) – 3-2. del: Mejne vrednosti – Mejne
vrednosti za oddajanje harmonskih tokov (vhodni tok opreme do vključno 16
A na fazo)

IEC 61000-3-11 Elektromagnetna združljivost (EMC) – 3-11. del: Mejne vrednosti – Omejitev
vrednosti kolebanja napetosti in flikerja v nizkonapetostnih napajalnih sistemih
– Oprema z naznačenim tokom ≤ 75 A, priključena pod posebnimi pogoji

IEC 61000-4-15:2010 Elektromagnetna združljivost (EMC) – 4-15. del: Preskusne in merilne tehnike
– Flikermeter – Specifikacije funkcij in zasnove

10

---------------------- Page: 14 ----------------------
SIST EN 61000-3-3 : 2014
3 Izrazi in definicije

V tem standardu veljajo naslednji izrazi in definicije:

3.1
fliker
vtis nestalnosti vidne zaznave, ki ga povzroča svetlobni dražljaj, katerega svetlost ali spektralna
porazdelitev se s časom spreminja

[VIR: IEC 60050-161:1990, 161-08-13]

3.2
karakteristika napetostne spremembe
d(t)
časovna funkcija relativne spremembe efektivne vrednosti napetosti, ovrednotena kot po ena vrednost
za vsako naslednjo polperiodo med prehodom napajalne napetosti skozi nič, razen med časovnimi
intervali, v katerih je napetost v ustaljenem stanju najmanj 1 sekundo

OPOMBA: Za podrobne informacije o oceni karakteristik napetostne spremembe in opredelitvi ustaljenega stanja glej
dodatek C in standard IEC 61000-4-15:2010.

3.3
d
c
največja napetostna sprememba v ustaljenem stanju v opazovalnem obdobju

OPOMBA: Za podrobnejše informacije o izračunu d glej dodatek C in standard IEC 61000-4-15:2010.
c

3.4
d
max
največja absolutna napetostna sprememba v opazovalnem obdobju

OPOMBA: Za podrobnejše informacije o izračunu d glej dodatek C in standard IEC 61000-4-15:2010.
max

3.5
Tmax
najdaljše trajanje v opazovalnem obdobju, ko odklon napetosti d(t) presega mejno vrednost za d
c

OPOMBA 1: Med karakteristiko napetostne spremembe se trajanje T akumulira, dokler se ne vzpostavi novo ustaljeno
max
stanje.

OPOMBA 2: Ocena mejne vrednosti T v tem standardu je na splošno namenjena ocenjevanju vzorca vklopnega toka
max
preskušane opreme. Zato se ovrednotenje T konča takoj po vzpostavitvi novega ustaljenega stanja. Če se
max
pojavi nova napetostna sprememba, ki presega mejno vrednost d , se začne novo ovrednotenje T . Najdaljše
c max
trajanje d(t), ki presega mejno vrednost za d , za katerokoli posamezno ovrednotenje T v opazovalnem obdobju,
c max
se uporabi za primerjavo z mejno vrednostjo T in se sporoči za preskus.
max

3.6
nazivna preskusna napetost
Un
nazivna preskusna napetost, ki se uporablja za izračun odstotkov za različne neposredno izmerjene
parametre

OPOMBA 1: Če v opazovalnem obdobju ni doseženo nobeno ustaljeno stanje, se za izračun d in T uporabi U .
max max n

OPOMBA 2: U ni nujno enak nazivni napetosti javnega elektroenergetskega omrežja.
n


...

Questions, Comments and Discussion