SIST EN 15655:2009
(Main)Ductile iron pipes, fittings and accessories - Internal polyurethane lining for pipes and fittings - Requirements and test methods
Ductile iron pipes, fittings and accessories - Internal polyurethane lining for pipes and fittings - Requirements and test methods
This European Standard defines the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 °C.
Rohre, Formstücke und Zubehörteile aus duktilem Gusseisen - Polyurethan-Auskleidung von Rohren und Formstücken - Anforderungen und Prüfverfahren
Diese Europäische Norm legt die Anforderungen und Prüfverfahren fest für werksseitig aufgebrachte Auskleidungen aus Polyurethan für den Korrosionsschutz bei starker Beanspruchung von erdüberdeckten Rohren und Formstücken aus duktilem Gusseisen nach EN 545, EN 598 und EN 969 für den Einsatz bei Betriebstemperaturen bis 45 °C.
Tuyaux, raccords er accessoires en fonte ductile - Revetement intérieur en polyuréthanne des tuyaux et raccords - Prescriptions et méthodes d'essais
La présente Norme européenne établit les prescriptions et les méthodes d’essais applicables aux revetements intérieurs en polyuréthane, appliqués en usine, et destinés a fournir une protection renforcée contre la corrosion pour les tuyaux et raccords en fonte ductile conformes a l'EN 545, l'EN 598 et l'EN 969, utilisables a des températures de service allant jusqu'a 45 °C.
Cevi, fitingi in dodatni deli iz nodularne litine - Notranja poliuretanska prevleka cevi in fitingov - Zahteve in preskusne metode
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Cevi, fitingi in dodatni deli iz nodularne litine - Notranja poliuretanska prevleka cevi in fitingov - Zahteve in preskusne metodeRohre, Formstücke und Zubehörteile aus duktilem Gusseisen - Polyurethan-Auskleidung von Rohren und Formstücken - Anforderungen und PrüfverfahrenTuyaux, raccords er accessoires en fonte ductile - Revetement intérieur en
polyuréthanne des tuyaux et raccords - Prescriptions et méthodes d'essaisDuctile iron pipes, fittings and accessories - Internal polyurethane lining for pipes and fittings - Requirements and test methods23.040.40Kovinski fitingiMetal fittings23.040.10Železne in jeklene ceviIron and steel pipesICS:Ta slovenski standard je istoveten z:EN 15655:2009SIST EN 15655:2009en,de01-april-2009SIST EN 15655:2009SLOVENSKI
STANDARD
SIST EN 15655:2009
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15655January 2009ICS 23.040.10; 23.040.40 English VersionDuctile iron pipes, fittings and accessories - Internalpolyurethane lining for pipes and fittings - Requirements and testmethodsTuyaux, raccords et accessoires en fonte ductile -Revêtement intérieur en polyuréthane des tuyaux etraccords - Prescriptions et méthodes d'essaisRohre, Formstücke und Zubehörteile aus duktilemGusseisen - Polyurethan-Auskleidung von Rohren undFormstücken - Anforderungen und PrüfverfahrenThis European Standard was approved by CEN on 22 November 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2009 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15655:2009: ESIST EN 15655:2009
EN 15655:2009 (E) 2 Contents Page Foreword .3 Introduction .4 1 Scope .5 2 Normative references .5 3 Terms and definitions .5 4 Ordering information .7 5 Technical Requirements .7 5.1 Surface preparation .7 5.2 Finished polyurethane lining .7 5.3 Pipe ends .8 5.4 Repairs .8 5.5 Marking .8 5.6 Non porosity .9 5.7 Hardness .9 5.8 Adhesion .9 6 Performance Requirements .9 6.1 Chemical resistance .9 6.2 Indirect Impact strength .9 6.3 Resistance to ovalization .9 6.4 Elongation at break. 10 6.5 Specific lining resistance . 10 6.6 Abrasion resistance (only for waste water application) . 10 6.7 Light ageing . 10 6.8 Materials in contact with water intended for human consumption . 11 7 Test Methods . 11 7.1 Routine tests . 11 7.2 Performance tests. 12 Annex A (informative)
Quality assurance . 15 A.1 General . 15 A.2 Performance test; DN grouping . 16 A.3 Quality assessment system . 17 Annex B (informative) Lining process and materials . 18 B.1 Lining application process . 18 B.2 Material properties . 18 B.3 Field of use, characteristics of transported waters . 19 Annex C (informative)
Packaging . 20 Bibliography . 21
SIST EN 15655:2009
EN 15655:2009 (E) 3 Foreword This document (EN 15655:2009) has been prepared by Technical Committee CEN/TC 203 “Cast iron pipes, fittings and their joints”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2009, and conflicting national standards shall be withdrawn at the latest by July 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 15655:2009
EN 15655:2009 (E) 4 Introduction This standard is in conformity with the general requirements already established by CEN/TC 164 in the field of water supply (e.g. potable water) and CEN/TC 165 in the field of waste water. In respect of potential adverse effects on the quality of water intended for human consumption, caused by the product covered by this standard: a) no information is provided as to whether the product may be used without restriction in any of the member states of the EU or EFTA; b) it should be noted that, while awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of this product remain in force. SIST EN 15655:2009
EN 15655:2009 (E) 5 1 Scope This European Standard defines the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 °C. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 545, Ductile iron pipes, fittings, accessories and their joints for water pipelines — Requirements and test methods EN 598:2007, Ductile iron pipes, fittings, accessories and their joints for sewerage applications — Requirements and test methods EN 969, Ductile iron pipes, fittings, accessories and their joints for gas pipelines — Requirements and test methods EN ISO 4624, Paints and varnishes — Pull-off test for adhesion (ISO 4624:2002) ISO 62:2008, Plastics — Determination of water absorption ISO 527–3:1995, Plastics — Determination of tensile properties – Part 3: Test conditions for films and sheets ISO 868, Plastics and ebonite — Determination of indentation hardness by means of a durometer (Shore hardness) ISO 8501–1:2007, Representative photographic examples of the change of appearance imparted to steel when blast-cleaned with different abrasives ISO 8503–1:1988, Preparation of steel substrates before application of paints and related products — Surface roughness characteristics of blast-cleaned steel substrates — Part 1: Specifications and definitions for ISO surface profile comparators for the assessment of abrasive blast-cleaned surfaces 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 ductile iron cast iron used for pipes, fittings and accessories in which graphite is present substantially in spheroidal form 3.2 adhesion force per unit area, applied perpendicular to the surface, which is necessary to separate the lining from its substrate 3.3 indirect impact strength impact energy applied from outside of the pipe with deformation to which a lining can withstand without damage under defined test conditions SIST EN 15655:2009
EN 15655:2009 (E) 6 3.4 hardness resistance of the lining to the penetration of a ball under defined test conditions 3.5 minimum lining thickness lower limit calculated for the polyurethane lining thickness by the mean value (x) minus two times the standard deviation (σ) 3.6 non porosity absence of holidays in a high voltage test under defined test conditions 3.7 polyurethane lining factory applied lining which consists of polyurethane on the inside of the pipe or fitting
Key 1 gasket seat 2 pipe barrel 3 spigot end 4 lining 5 internal socket profile Figure 1 — Location of the defined pipe areas
Key 1 lining 2 internal socket profile Figure 2 — Location of the defined fitting areas SIST EN 15655:2009
EN 15655:2009 (E) 7 3.9 specific lining resistance surface related electric resistance of the lining perpendicular to the pipe wall 3.10 performance test test which is done once and is repeated according to a schedule or after relevant change of lining material
and/or material supplier or change in process application 3.11 routine test test carried out to control the manufacturing process with a frequency defined by the manufacturer 4 Ordering information The following information shall be supplied to the manufacturer by the purchaser. Ductile iron pipes according to EN 545, EN 598 or EN 969 but internally coated in accordance with this European Standard shall be specified in the purchaser's enquiry and order by reference to this standard, e.g. 5 000 m of ductile iron pipe DN 300 according to EN 545, internal polyurethane lining according to EN 15655; or 10 pieces of ductile cast iron fittings DN 300 according to EN 598, internal PUR-lining according to EN 15655. 5 Technical Requirements 5.1 Surface preparation Prior to application of the polyurethane lining, the surface of the pipes or fittings to be lined shall be clean, free of rust, loose constituent materials, dirt, oil, grease and moisture. In cold weather, or anytime when the moisture tends to condense on the surface of the pipe or fitting, it shall be uniformly warmed for sufficient time to dry prior to cleaning. The surface temperature shall be maintained at least 5 °C above the dew point. The surface shall be prepared by grinding (only for pipes) and grit blasting and be in compliance with level Sa 2-2.5 of ISO 8501-1 when checked according to 7.1.1. The surface roughness Ra in accordance with ISO 8503-1 shall be at least 12,5 micrometers which is equivalent to an anchored profile Rz of 63 micrometers or higher if required by the lining material provider or manufacturer. 5.2 Finished polyurethane lining 5.2.1 Appearance and continuity The polyurethane lining shall be of: uniform colour, except the spigot end and the internal socket profile which may be of a different colour and different coating material; uniform appearance and smoothness except for admissible repairs; free of visible defects (pinholes, bubbles, blisters, wrinkles, cracks or voids). SIST EN 15655:2009
EN 15655:2009 (E) 8 Slight superficial variations of colour or brilliance due to repairs or prolonged exposure to sunlight or contact with other pipes are permissible. 5.2.2 Minimum lining thickness When measured in accordance with 7.1.3, the lining thickness shall be as indicated in Table 1a for drinking water application and in Table 1b for waste water application. Table 1a — Lining thickness of pipes and fittings for drinking water transport according to EN 545 DN mean value x µm (x-2σσσσ) µm 80 - 200 ≥ 1 300 ≥ 800 > 200 ≥ 1 500 Table 1b — Lining thickness of pipes and fittings for waste water transport according to EN 598 DN mean value x µm (x-2σσσσ) µm 80 - 200 ≥ 1 300
≥ 800 250 - 700 ≥ 1 500
≥ 800 700 – 1 000 ≥ 1 800
≥ 1 000 > 1 000 ≥ 2 000
≥ 1 000 5.3 Pipe ends Spigot end and internal socket profile (see Figure 1) shall be coated with one of the following: epoxy lining in accordance with EN 14901; polyurethane in accordance with this standard with a minimum lining thickness of 150 µm; bituminous paint (only for drinking water); multilayer of epoxy, PUR-Epoxy. When spigot end and socket entrance are coated with epoxy or polyurethane, the manufacturer shall ensure that the joint can be assembled. The coating thickness shall be checked according to 7.1.4. 5.4 Repairs In case of holidays or damage, repairs shall be carried out in accordance with the manufacturer’s written instructions. Repairs shall be checked according to 7.1.5. Fresh surfaces of pipes cut on site shall be protected by appropriate coatings according to the manufacturer's written instructions. 5.5 Marking All pipes shall be marked legibly and durably according to the pipe standard EN 545, EN 598 or EN 969. Reference to this standard shall be legibly and durably applied by any method upon the external surface. SIST EN 15655:2009
EN 15655:2009 (E) 9 This shall be checked according to 7.1.6. 5.6 Non porosity When tested in accordance with the test method described in 7.1.7 with a tension of 3,0 kV for mean lining thickness up to 1 500 µm and 4 kV for mean lining thickness greater than 1 500 µm, the lining shall be free from porosity. 5.7 Hardness When assessed by testing in accordance with 7.1.8, the hardness of the polyurethane lining shall be at minimum 70 Shore D. Testing temperature shall be within the range of 10 °C to 30 °C. 5.8 Adhesion The adhesion shall be at least 8 MPa when tested in accordance with 7.1.9. 6 Performance Requirements 6.1 Chemical resistance
The chemical resistance is determined by the change in weight of the polyurethane lining. When tested in accordance with 7.2.1, the weight increase resp. weight loss shall meet the requirements given in Table 2 when compared to the original weight. Table 2 — Weight changes requirements Property Unit Test method Clause Requirement Mass change after
100 days in deionised water at 50 °C % Immersion test 7.2.1.1 Less than 15 % weight increase Mass change after subsequent drying % ISO 62, method 2
Less than 2 % weight loss Mass change after 100 days in sulphuric acid 10 % at 50 °C % Immersion test 7.2.1.2 Less than 10 % weight increase Mass change after subsequent drying % ISO 62, method 2
Less than 4 % weight loss 6.2 Indirect Impact strength Due to handling activities, the PU-lined pipes may fall or get impacts from outside with minor plastic deformations which can cause damages on the lining.
The minimum impact strength shall be determined in accordance with the test method defined in 7.2.2 with an impact energy E of at least 50 joules. The lining shall subsequently show no damage when tested in accordance with 7.1.7. 6.3 Resistance to ovalization When tested according to 7.2.3, the pipe shall comply with the requirements of 6.3.1 and subsequently 6.3.2. SIST EN 15655:2009
EN 15655:2009 (E) 10 6.3.1 Integrity under service conditions There shall be no detrimental damage to the polyurethane lining when the lined pipe is tested in accordance with 7.2.3 and subjected to an ovalization not less t
...