Safety devices for protection against excessive pressure - Part 4: Pilot operated safety valves (ISO 4126-4:2004)

This European Standard specifies general requirements for pilot operated safety valves, other than those covered in Part 1, irrespective of the fluid for which they are designed. In all cases, the operation is carried out by the fluid in the system to be protected.
It is applicable to pilot operated safety valves having a valve flow diameter of 6 mm and above which are for use at set pressures of 0,1 bar gauge and above. No limitation is placed on temperature.
This is a product standard and it is not concerned with applications for pilot operated safety valves.

Sicherheitseinrichtungen gegen unzulässigen Überdruck - Teil 4: Pilotgesteuerte Sicherheitsventile (ISO 4126-4:2004)

Dieser teil der Europäischen Norm legt allgemeine Anforderungen an andere pilotgesteuerte Sicherheitsventile als im Teil 1 behandelte fest, unabhängig von dem Medium, für das diese Ventile vorgesehen sind. Die Funktion wird in allen Fällen durch das Medium in dem zu schützenden System ausgelöst. Die Norm gilt für pilotgesteuerte Sicherheitsventile mit einem engsten Strömungsdurchmesser von mindestens 6 mm und für Ansprechdrücke von 0,1 bar und höher. Hinsichtlich der Temperatur bestehen keine Einschränkungen.

Dispositifs de sécurité pour protection contre les pressions excessives - Partie 4: Soupapes de sureté pilotées (ISO 4126-4:2004)

La présente partie de cette norme européenne donne les prescriptions générales des soupapes de sureté pilotées, autres que celles couvertes par la partie 1, quel que soit le fluide pour lequel elles sont conçues. Dans tous les cas, elles fonctionnent avec le fluide du systeme a protéger. Elle est applicable aux soupapes de sureté présentant un orifice d'écoulement de diametre supérieur ou égal a 6 mm qui sont utilisables a des pressions de début d'ouverture de 0,1 bar effectif. Aucune limitation en température n'est spécifiée.

Naprave za varovanje pred visokim tlakom - 4. del: Predkrmiljeni varnostni ventili (ISO 4126-4:2004)

General Information

Status
Withdrawn
Publication Date
31-Aug-2004
Withdrawal Date
25-Jul-2013
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
25-Jul-2013
Due Date
17-Aug-2013
Completion Date
26-Jul-2013

Relations

Buy Standard

Standard
EN ISO 4126-4:2004
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 4126-4:2004
01-september-2004
Naprave za varovanje pred visokim tlakom - 4. del: Predkrmiljeni varnostni ventili
(ISO 4126-4:2004)
Safety devices for protection against excessive pressure - Part 4: Pilot operated safety
valves (ISO 4126-4:2004)
Sicherheitseinrichtungen gegen unzulässigen Überdruck - Teil 4: Pilotgesteuerte
Sicherheitsventile (ISO 4126-4:2004)
Dispositifs de sécurité pour protection contre les pressions excessives - Partie 4:
Soupapes de sureté pilotées (ISO 4126-4:2004)
Ta slovenski standard je istoveten z: EN ISO 4126-4:2004
ICS:
13.240
SIST EN ISO 4126-4:2004 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD
EN ISO 4126-4
NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2004
ICS 13.240
English version
Safety devices for protection against excessive pressure - Part
4: Pilot operated safety valves (ISO 4126-4:2004)
Dispositifs de sécurité pour protection contre les pressions Sicherheitseinrichtungen gegen unzulässigen Überdruck -
excessives - Partie 4: Soupapes de sûreté pilotées (ISO Teil 4: Pilotgesteuerte Sicherheitsventile (ISO 4126-4:2004)
4126-4:2004)
This European Standard was approved by CEN on 16 May 2003.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2004 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 4126-4:2004: E
worldwide for CEN national Members.

---------------------- Page: 2 ----------------------

EN ISO 4126-4:2004 (E)
Contents
Page
1 Scope .4
2 Normative references .4
3 Terms and definitions.4
4 Symbols and units .9
5 Design .9
5.1 General.9
5.2 End connections .10
5.3 Minimum requirements for springs.12
5.4 Materials.12
6 Production testing .12
6.1 Purpose.12
6.2 General.12
6.3 Hydrostatic testing .12
6.4 Pneumatic testing .13
6.5 Adjustment of set or cold differential test pressure .14
6.6 Seat leakage test.14
6.7 Pressure seals.15
7 Type testing.15
7.1 General.15
7.2 Tests to determine operating characteristics.16
7.3 Tests to determine flow characteristics .18
7.4 Determination of the coefficient of discharge .19
7.5 Certification of coefficient of discharge .19
8 Determination of pilot operated safety valve performance .20
8.1 Determination of coefficient of discharge.20
8.2 Critical and subcritical flow .20
8.3 Discharge capacity at critical flow .20
8.4 Discharge capacity for any gas at subcritical flow .21
8.5 Discharge capacity for non-flashing liquid as the test medium in the turbulent zone where the
Reynolds number R is equal to or greater than 80 000 .21
e
9 Sizing of pilot operated safety valves.21
9.1 General.21
9.2 Valves for gas or vapour relief .21
9.3 Calculation of capacity.22
10 Marking and sealing .23
10.1 Marking .23
10.2 Sealing of a pilot operated safety valve .24
Annex A (informative) Examples of capacity calculations for various media .25
A.1 Capacity calculations for gaseous media at critical flow (see 9.3.3.1) .25
A.2 Capacity calculations for gaseous media at subcritical flow (see 9.3.3.2) .27
A.3 Capacity calculations for liquids (see 9.3.4) .28
Annex ZA (informative) Relationship between this European Standard and the Essential Requirements
of EU Directive 97/23/EC (PED).30
2

---------------------- Page: 3 ----------------------

EN ISO 4126-4:2004 (E)
Foreword
This document (EN ISO 4126-4:2004) has been prepared by Technical Committee CEN/TC 69 “Industrial valves”,
the secretariat of which is held by AFNOR, in collaboration with Technical Committee ISO/TC 185 “Safety devices
for protection against excessive pressure”.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by August 2004, and conflicting national standards shall be withdrawn at the latest by
August 2004.
This document has been prepared under a mandate given to CEN by the European Commission and the European
Free Trade Association, and supports essential requirements of EU Directive.
For relationship with EU Directive, see informative annex ZA, which is an integral part of this document.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
This standard for safety devices for protection against excessive pressure consists of seven parts of which this is
Part 4. The various parts are:
 Part 1 : Safety valves
 Part 2 : Bursting disc safety devices
 Part 3 : Safety valves and bursting disc safety devices in combination
 Part 4 : Pilot operated safety valves
 Part 5 : Controlled safety pressure relief systems (CSPRS)
 Part 6 : Application, selection and installation of bursting disc safety devices
 Part 7 : Common data
Part 7 contains data that is common to more than one of the parts of this standard to avoid unnecessary repetition.
Annex A is informative.
3

---------------------- Page: 4 ----------------------

EN ISO 4126-4:2004 (E)
1 Scope
This part of this European Standard specifies general requirements for pilot operated safety valves, other than
those covered in Part 1, irrespective of the fluid for which they are designed. In all cases, the operation is carried
out by the fluid in the system to be protected.
It is applicable to pilot operated safety valves having a valve flow diameter of 6 mm and above which are for use at
set pressures of 0,1 bar gauge and above. No limitation is placed on temperature.
This is a product standard and it is not concerned with applications for pilot operated safety valves.
2 Normative references
This European Standard incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed hereafter. For
dated references, subsequent amendments to or revisions of any of these publications apply to this European
Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the
publication referred to applies (including amendments).
EN 1092-1, Flanges and their joints – Circular flanges for pipes, valves, fittings and accessories PN designated –
Part 1: Steel flanges.
EN 1092-2, Flanges and their joints – Circular flanges for pipes, valves, fittings and accessories PN designated –
Part 2: Cast iron flanges.
EN 1092-3 , Flanges and their joints – Circular flanges for pipes, valves, fittings and accessories PN designated –
Part 3: Copper alloy and composite flanges.
prEN 1759-1, Flanges and their joints – Circular flanges for pipes, valves, fittings and accessories, Class
designated – Part 1: Steel flanges NPS1/2 to 24.
EN 12516-3, Valves – Shell design strength – Part 3: Experimental method.
EN 12627, Industrial Valves – Butt welding ends for steel valves.
EN 12760, Valves – Socket welding ends for steel valves.
EN ISO 6708, Pipework components – Definition and selection of DN (nominal size) (ISO 6708:1995).
ISO 7-1, Pipe threads where pressure-tight joints are made on the threads — Part 1: Dimensions, tolerances and
designation.
ASME B1.20.1, NPT threads.
3 Terms and definitions
For the purposes of this European Standard, the following terms and definitions apply.
3.1
pilot operated safety valve
self actuated device comprising a valve and an attached pilot
NOTE The pilot responds to the pressure of the fluid without any other energy than the fluid itself and controls the
operation of the valve. The valve opens when the fluid pressure that keeps it closed is removed or reduced. The valve re-closes
when the pressure is re-applied.
4

---------------------- Page: 5 ----------------------

EN ISO 4126-4:2004 (E)
3.1.1
types of pilot
3.1.1.1
flowing pilot
pilot which discharges the fluid throughout the relieving cycle of the pilot operated safety valve
3.1.1.2
non-flowing pilot
pilot in which the fluid flows only during the opening and/or closing of the pilot operated safety valve
3.1.2
types of action of the pilot operated safety valve
3.1.2.1
ON/OFF
action characterised by stable operation resulting in fully open or fully closed main valve position
3.1.2.2
modulating
action characterised by a gradual opening and closing of the disc of the main valve which is a function of the
pressure, proportional but not necessarily linear
3.2
list of main components
see Figure 1
5

---------------------- Page: 6 ----------------------

EN ISO 4126-4:2004 (E)
Key
1 Equipment to be protected 9 Disc
2 Main valve 10 Seat
3 Pilot valve 11 Body
4 Sensing line 12 Inlet
5 Loading/unloading line 13 Outlet
6 Pressure chamber 14 Pilot outlet
7 Cover 15 Connection of the sensing line : see the following note
8 Guide
NOTE The sensing line from the pilot can be either connected to the main valve inlet or connected directly to the
equipment to be protected. In cases where the sensing line is not connected to the main valve inlet, considerations should be
given to the length and to the protection from damage of the sensing line.
Figure 1 — Nomenclature of main components of a pilot operated safety valve
3.3
pressure
3.3.1
set pressure
predetermined pressure at which the valve of a pilot operated safety valve under operating conditions commences
to open
NOTE It is the gauge pressure measured at the valve inlet at which the pressure forces tending to open the valve for the
specific service conditions are in equilibrium with the forces retaining the valve disc on its seat.
6

---------------------- Page: 7 ----------------------

EN ISO 4126-4:2004 (E)
3.3.2
maximum allowable pressure, PS
maximum pressure for which the equipment is designed as specified by the manufacturer
3.3.3
opening sensing pressure
pressure at which the pilot commences to open in order to achieve the set pressure
3.3.4
overpressure (of a pilot operated safety valve)
pressure increase over the set pressure, at which the main valve attains the lift specified by the manufacturer,
usually expressed as a percentage of the set pressure
NOTE This is the overpressure used to certify the pilot operated safety valve.
3.3.5
reseating pressure (of a pilot operated safety valve)
value of the inlet static pressure at which the disc re-establishes contact with the seat or at which the lift becomes
zero
3.3.6
cold differential test pressure
inlet static pressure at which a pilot operated safety valve is set to commence to open on the test bench
NOTE This test pressure includes corrections for service conditions, e.g., back pressure and/or temperature.
3.3.7
relieving pressure
pressure used for the sizing of a pilot operated safety valve which is greater than or equal to the set pressure plus
overpressure
3.3.8
built-up back pressure
pressure existing at the outlet of the main valve caused by flow through the main valve and the discharge system
3.3.9
superimposed back pressure
pressure existing at the outlet of the main valve at the time when the device is required to operate
NOTE It is the result of pressure in the discharge system from other sources.
3.3.10
blowdown (of a pilot operated safety valve)
difference between set and reseating pressures, normally stated as a percentage of set pressure except for
pressures of less than 3 bar when the blowdown is expressed in bar
3.4
lift
actual travel of the main valve disc away from the closed position
3.5
flow area
minimum cross-sectional flow area (but not the curtain area) between inlet and seat which is used to calculate the
theoretical flowing capacity of the main valve, with no deduction for any obstruction
NOTE The symbol is A.
3.6
flow diameter
diameter corresponding to the flow area
7

---------------------- Page: 8 ----------------------

EN ISO 4126-4:2004 (E)
3.7
discharge capacity
3.7.1
theoretical discharge capacity
calculated capacity expressed in mass or volumetric units of a theoretically perfect nozzle having a cross-sectional
flow area equal to the flow area of a main valve
3.7.2
coefficient of discharge
value of actual flowing capacity (from tests) divided by the theoretical flowing capacity (from calculation)
3.7.3
certified (discharge) capacity
that portion of the measured capacity permitted to be used as a basis for the application of a pilot operated safety
valve
NOTE It may, for example, equal the :
a) measured flow rate times the derating factor ; or
b) theoretical flow rate times the coefficient of discharge times the derating factor ; or
c) theoretical flow rate times the certified derated coefficient of discharge.
3.8
DN (nominal size)
see EN ISO 6708
8

---------------------- Page: 9 ----------------------

EN ISO 4126-4:2004 (E)
4 Symbols and units
Table 1 — Symbols and their descriptions
Symbol Description Unit
2
A
Flow area of a safety valve (not curtain area)
mm
C Function of the isentropic exponent -
K Theoretical capacity correction factor for subcritical flow -
b
a
K
Coefficient of discharge -
d
a
K -
Certified derated coefficient of discharge (K · 0,9)
dr
d
K Viscosity correction factor -
v
k
Isentropic exponent -
M Molar mass kg/kmol
n Number of tests -
p Relieving pressure bar (abs.)
o
p Back pressure bar (abs.)
b
p
Critical pressure bar (abs.)
c
Q Mass flow rate kg/h
m
2
q Theoretical specific discharge capacity
kg/(h·mm )
m
2
q’
Specific discharge capacity determined by tests
kg/(h·mm )
m
R Universal gas constant -
T
Relieving temperature K
o
Tc Actual critical temperature K
mDynamic viscosity Pa·s
3
v Specific volume at actual relieving pressure and temperature
m /kg
o
x Dryness fraction of wet steam at the valve inlet at actual relieving pressure and -
o
b
temperature
Z
Compressibility factor at actual relieving pressure and temperature -
a
K and K are expressed as 0,xxx.
d dr
b
x is expressed as 0,xx.
5 Design
5.1 General
5.1.1 The design shall incorporate guiding arrangements necessary to ensure consistent operation and seat
tightness.
5.1.2 The seat of the main valve, other than when it is an integral part of the valve shell, shall be fastened
securely to prevent the seat becoming loose in service.
5.1.3 Means shall be provided to lock and/or to seal all external adjustments in such a manner so as to prevent
or reveal unauthorized adjustments of the pilot operated safety valve.
9

---------------------- Page: 10 ----------------------

EN ISO 4126-4:2004 (E)
5.1.4 In the case of main valves with restricted lift, the lift restricting device shall limit the main valve lift but shall
not otherwise interfere with the operation of the main valve. The lift restricting device shall be designed so that, if
adjustable, the adjustable feature can be mechanically locked and sealed. The lift restricting device shall be
installed and sealed by the valve manufacturer.
Valve lift shall not be restricted to a value less than 1 mm.
5.1.5 Pilot operated safety valves for toxic or flammable fluids shall have the pilot vented to a safe place.
5.1.6 The main valve shall be provided with a drain connection at the lowest point where liquid can collect unless
other provisions for draining are provided.
5.1.7 The design stress of load carrying parts shall not exceed that specified in the appropriate European
Standard, e.g. EN 12516-3.
5.1.8 In the case of failure of any sealing elements, the pilot operated safety valve shall discharge its certified
capacity at not over 1,1 times the maximum allowable pressure of the equipment to be protected.
5.1.9 The materials for adjacent sliding surfaces such as guides and disc/disc holder/spindle shall be selected to
ensure corrosion resistance and to minimise wear and avoid galling.
5.1.10 In the case of reasonably foreseeable damage to connections between the various components the
resulting flow areas shall be such that the pilot operated safety valve will discharge its certified capacity at not more
than 1,1 times the maximum allowable pressure.
5.1.11 When the superimposed back pressure is higher than the inlet pressure, means shall be provided that the
main valve shall not open.
5.1.12 The fitting of any additional device to a pilot and valve combination shall not prevent the pressurized
system from being protected under any circumstances.
5.2 End connections
5.2.1 Types
The types of end connections for pilot operated safety valves shall be as follows:
Butt welding EN 12627 ;
Socket welding EN 12760 ;
Flanged EN 1092-1 ;
EN 1092-2 ;
EN 1092-3 ;
prEN 1759-1 ;
Threaded ISO 7-1 or ASME B1.20.1.
Other types of end connections are possible by agreement between the manufacturer and purchaser.
5.2.2 Design of valve end connections
The design of valve end connections, whatever their type, shall be such that the internal area of the external pipe
or stub connection at the safety valve inlet is at least equal to that of the valve inlet connection (see Figure 2a).
10

---------------------- Page: 11 ----------------------

EN ISO 4126-4:2004 (E)
The internal area of the external pipe connection at the safety valve outlet shall be at least equal to that of the valve
outlet, except those valves with female threaded outlet connections (see Figure 2b).
NOTE See clause 7 regarding type testing.
Key
1Valve
2 Satisfactory
3 Unsatisfactory
4 Required internal diameter of the safety valve for the valve to function properly
Figure 2 a) — Inlet
Key
1Valve
2 The nominal diameter of the pipe to be equal to the nominal diameter of the valve outlet
With this construction at the valve outlet, a suitable pipe shall be fitted during testing as specified in 7.1.4.
Figure 2 b) — Outlet
11

---------------------- Page: 12 ----------------------

EN ISO 4126-4:2004 (E)
Key
1Valve
With this construction at the valve outlet, no pipe is required during testing as specified in 7.1.4.
Figure 2 c) — Outlet
Figure 2 — Design of end connections
5.3 Minimum requirements for springs
Springs shall be in accordance with Part 7 of this standard.
5.4 Materials
The materials for pressure retaining shells shall be in accordance with Part 7 of this standard.
6 Production testing
6.1 Purpose
The purpose of these tests is to ensure that all pilot operated safety valves meet the requirements for which they
have been designed without exhibiting any form of leakage from pressure retaining components or joints.
6.2 General
All temporary pipes, connections and blanking devices shall be adequate to withstand the test pressure.
Any temporary welded-on attachments shall be carefully removed and the resulting weld scars shall be ground
flush with the parent material. After grinding, all such scars shall be inspected by using magnetic particle or liquid
penetrant techniques.
6.3 Hydrostatic testing
6.3.1 Application
The portion of the main valve from the inlet to the seat shall be tested to a pressure 1,5 times the manufacturer's
stated maximum pressure for which the pilot operated safety valve is designed.
The shell on the discharge side of the seat shall be tested to 1,5 times the manufacturer's stated maximum back
pressure for which the valve is designed. This pressure can be lower than that given by the outlet flange rating.
12

---------------------- Page: 13 ----------------------

EN ISO 4126-4:2004 (E)
6.3.2 Duration
The test pressure shall be applied and maintained at the required magnitude for a sufficient length of time to permit
a visual examination to be made of all surfaces and joints, but in any case for not less than the times given in
Table 2. For tests on the discharge side of the seat, the testing time shall be based on the pressure specified
in 6.3.1 and the discharge size.
Table 2 — Minimum duration of hydrostatic test
Pressure rating
Nominal size
Up to 40 bar Greater than 40 bar (4 MPa) up Greater than 63 bar
(4 MPa) to 63 bar (6,3 MPa) (6,3 MPa)
DN
Minimum duration in minutes
22 3
     DN £  50
22 4
 50 < DN £  65
 65 < DN £  80 23 4
 80 < DN £ 100 24 5
100 < DN £ 125 24 6
125 < DN £ 150 25 7
150 < DN £ 200 35 9
200 < DN £ 250 36 11
250 < DN £ 300 47 13
300 < DN £ 350 48 15
350 < DN £ 400 49 17
400 < DN £ 450 49 19
450 < DN £ 500 510 22
512 24
500 < DN £ 600
6.3.3 Acceptance criteria
No leakage from the tested parts as defined in 6.3.1 is accepted.
6.3.4 Safety requirements
Water of suitable purity shall normally be used as the test medium. Where other testing media are used, additional
precautions may be necessary. Valve bodies shall be properly vented to remove entrapped air.
If materials which are liable to failure by brittle fracture are incorporated in that part of the pilot operated safety
valve which is to be hydrostatically tested, then both the pilot operated safety valve, or part thereof, and the testing
medium shall be at a sufficient temperature to prevent the possibility of such failure.
No valve or part thereof undergoing pressure testing shall be subjected to any form of shock loading, for example
hammer testing.
6.4 Pneumatic testing
6.4.1 Application and duration of test
Pressure testing with air or other suitable gas should be avoided but may be carried out in place of the standard
body hydrostatic test with the agreement of all parties involved in the following cases :
13

---------------------- Page: 14 ----------------------

EN ISO 4126-4:2004 (E)
a) valves of such design and construction that it is not practicable for them to be filled with liquid ; and/or
b) valves that are to be used in service where even small traces of water cannot be tolerated.
The test pressure, duration of application and acceptance criteria shall be as specified in 6.3.
6.4.2 Safety requirements
The hazards involved in pneumatic pressure testing shall be considered and adequate precautions taken.
Particular attention is drawn to some relevant factors as follows:
a) If a major rupture of the valve should occur at some stage during application of pressure, considerable energy
will be released ; hence no personnel should be in the immediate vicinity during pressure raising (for example
a given volume of air contains 200 times the amount of energy that a similar volume of water contains when
both are at the same pressure) ;
b) The risk of brittle failure under test conditions shall have been critically assessed at the design stage and the
choice of materials for valves which are to be pneumatically tested shall be such as to avoid the risk of brittle
failure during test. This necessitates provision of an adequate margin between the transition temperature of all
parts and the metal temperature during testing ;
c) Attention is drawn to the fact that if there is a reduction in gas pressure between the high pressure storage and
the valve under test, the temperature will decrease.
Valves undergoing pneumatic test should not be approached for close inspection until after the pressure increase
has been completed.
No valve undergoing pneumatic test shall be subject to any form of shock loading.
Precautions shall be taken against pressures generated in excess of test pressure.
6.5 Adjustment of set or cold differential test pressure
Each pilot operated safety valve shall be adjusted to its designated set or cold differential test pressure.
It is not permissible to adjust the set or cold differential test pressure of a pilot operated safety valve using air or
other gas as the test medium unless the pressure retaining parts have previously been subjected to a test in
accordance with 6.3 or 6.4.
It is permissible to establish the set or cold differential test pressure by adjustment of the pilot only. In cases such
as these, it shall be shown that the opening sensing pressure of the pilot achieves the required set pressure of the
main valve.
6.6 Seat leakage test
6.6.1 General
The seat leakage test of the pilot operated safety valve shall be carried out after the adjustment of the set or the
cold differential test pressure. The test
...