The Slovenian Institute for Standardization is recognized as the national standards body in the Republic of Slovenia. SIST develops, adopts and maintains Slovenian standards, and participates in the work of international (ISO, IEC, ITU-T) and European Standardisation Organisations (CEN, CENELEC, ETSI) where its experts represent national interests.
SIST represents Slovenia in European (CEN, CENELEC, ETSI) and international standards organizations (ISO, IEC). As part of the European Union, SIST adopts European standards, ensuring alignment and harmonization with broader European standards.
IEC 62820-1-1 specifies the technical requirements for the composition, functions, performance, and test methods of general building intercom systems.
This document is applicable to the general intercom systems for building entry in residential or commercial buildings.
Door-Entry-System (DES) is a simple kind of convenient Building-Intercom-System (BIS) mainly for user’s comfort. This document has classified the general building intercom systems into two grades in IEC 62820-1-1. Grade 1 adopts lower requirements to cover DES not used for relevant security applications while grade 2 adopts higher requirements for building intercom systems for security applications. Each grade can adopt different functional and performance requirements, test methods and normative references.
NOTE The different requirements between grade 1 and grade 2 are summarized in Table C.1 of Annex C.
- Standard47 pagesEnglish languagee-Library read for1 day
This document specifies a method of preparing a ground sample of spice or condiment for analysis, from a laboratory sample obtained by the method specified in ISO 948.
This document is applicable to the majority of spices and condiments. However, in view of the large number and diversity of spices and condiments, it can be necessary in certain special cases, for example, considerable hardness, or high moisture, volatile oil or fat content, to use a modified procedure or to choose another more
suitable method. Any such modified procedure or alternative method will be indicated in the International Standard appropriate to the spice or condiment concerned.
- Standard9 pagesEnglish languagee-Library read for1 day
This document is applicable to all electronic equipment for control, regulation, protection, diagnostic, energy supply installed on railway vehicles and any relevant elements of rolling stock subsystems (e.g. external doors, On-Board ETCS functionality, wheel slide protection).
For the purpose of this document, electronic equipment is defined as equipment composed of electronic components (e.g. resistors, capacitors, transistors, diodes, integrated circuits, hybrids, application specific integrated circuits, wound components and relays), and recognized associated components (e.g. connectors, mechanical parts). These components are mainly mounted on printed circuit boards.
Sensors (e.g. current, voltage, speed) and semiconductor drive units for power electronic devices are covered by this document. Complete semiconductor drive units and power converters are covered by EN 61287 1.
This document covers the requirements for operating conditions, design, documentation, testing and integration of electronic equipment, as well as hardware and software requirements considered necessary for compliant and reliable equipment.
Specific requirements related to practices necessary to ensure defined safety integrity level or functional safety are not covered by this document. Nevertheless, this document is applicable to the hardware of all rolling stock electronic equipment or systems performing safety-related functions.
The software development requirements for on-board railway equipment are specified by EN 50716.
- Standard112 pagesEnglish languagee-Library read for1 day
This document gives guidance and requirements for the assessment of conformity of formulations, products and assemblies in accordance with EN 1329-1:2026 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1 A basic test matrix provides an overview of the testing scheme in Annex A, Table A.1.
NOTE 2 If certification is involved, the certification body operating in accordance with EN ISO/IEC 17065[1] and EN ISO/IEC 17020[2] is considered to be competent.
- Technical specification22 pagesEnglish languagee-Library read for1 day
This document is applicable to ventilation systems in commercial kitchens, associated areas and other installations processing foodstuffs intended for commercial use. Kitchens and associated areas are special rooms in which meals are prepared, where tableware and equipment are washed and cleaned, food is stored, and food waste areas.
This document specifies requirements and gives recommendations for the configuration, installation, testing, maintenance and safety of fixed kitchen fire extinguishing systems within the design of commercial kitchens in buildings. It is applicable for fire extinguishing systems providing appliance-specific protection as well as overlapping zone protection.
This document provides the guidelines to install fixed fire extinguishing systems to protect against grease fires on the cooking appliances in the extract ventilation system. This document includes recommendations for the certification of system hardware, as well as design, installation and maintenance of the system.
NOTE It is possible that there are additional or alternative local national regulations on installation, appliance requirements and inspection, maintenance and operation.
This document is applicable to kitchen ventilation systems excluding those in domestic kitchens.
- Standard14 pagesEnglish languagee-Library read for1 day
This document specifies a semantic data model of the core elements of an Electronic invoice. The semantic data model includes only the essential information elements that an Electronic invoice needs to ensure legal (including fiscal) compliance and to enable interoperability for cross-border, cross sector and domestic trade. The semantic data model can be applied by organizations in the private and the public sector for public procurement invoicing. It can also be used for invoicing between private sector enterprises. It has not been specifically designed for invoicing consumers.
This document complies at least with the following criteria:
— it is technologically neutral;
— it is compatible with relevant international standards on electronic invoicing;
— the application of this standard should comply with the requirements for the protection of personal data of Directive 95/46/EC, having due regard to the principles of privacy and data protection bydesign, data minimization, purpose limitation, necessity and proportionality;
— it is consistent with the relevant provisions of Directive 2006/112/EC [2];
— it allows for the establishment of practical, user-friendly, flexible and cost-efficient electronic invoicing systems;
— it takes into account the special needs of small and medium-sized enterprises as well as of subcentral contracting authorities and contracting entities;
— it is suitable for use in commercial transactions between enterprises.
- Standard163 pagesEnglish languagee-Library read for1 day
This document specifies methods for the determination of seam maximum force of sewn seams when the force is applied perpendicularly to the seam. It describes the method known as the grab test.
The method defined in this document is applicable to woven textile fabrics, including fabrics which exhibit stretch characteristics imparted by the presence of an elastomeric fibre, mechanical or chemical treatment. It can be applicable to fabrics produced by other techniques. It is normally not applicable to geotextiles, nonwovens, coated fabrics, textile-glass woven fabrics and fabrics made from carbon fibres or polyolefin tape yarns.[2], [3], [4]
This method is applicable to straight seams only (obtained from previously sewn articles or prepared from fabric samples) and not to curved seams (see Annex B for considerations on seams).
The method is restricted to the use of constant-rate-of-extension (CRE) testing machines.
- Standard21 pagesEnglish languagee-Library read for1 day
IEC 61375-1:2026 applies to the architecture of data communication systems in open trains, i.e. it covers the architecture of a communication system for the data communication between vehicles of the said open trains, the data communication within the vehicles and the data communication from train to the ground. The applicability of IEC 61375-1 to the train network technologies allows for interoperability of individual vehicles within open trains in international traffic. The data communication systems inside vehicles are given as recommended solutions to cope with the said TCN. In any case, proof of compatibility between a proposed train backbone and a proposed consist network will have to be brought by the supplier. IEC 61375-1 might be additionally applicable to closed trains and multiple unit trains when so agreed between purchaser and supplier. This fourth edition cancels and replaces the third edition published in 2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Extension of train backbone topologies: aggregated and segregated topology;
b) Added independent consist orientation check with segregated train backbone topology;
c) Introduction of wireless technologies: wireless train backbone and wireless consist network;
d) Possibility of virtual networks;
e) Definition of data classes and protocol requirements suitable for the OMTS domain;
f) New clause about cybersecurity in train communication networks.
- Standard66 pagesEnglish languagee-Library read for1 day
The present document defines specific QCStatement for the qcStatements extension as defined in IETF RFC 3739 [2], clause 3.2.6, including requirements for their use in EU qualified certificates. Some of these QCStatements can be used for other forms of certificate. The QCStatements defined in the present document can be used in combination with any certificate profile, either defined in ETSI EN 319 412-2 [i.2], ETSI EN 319 412-3 [i.5] and ETSI EN 319 412-4 [i.6], or defined elsewhere. The QCStatements defined in clause 4.3 can be applied to regulatory environments outside the EU. Other requirements specified in clause 4 are specific to Regulation (EU) No 910/2014 [i.8] but may be adapted for other regulatory environments.
- Standard21 pagesEnglish languagesale 15% off
- Standard21 pagesEnglish languagesale 15% off
- Standard21 pagesEnglish languagee-Library read for1 day
This document specifies processes for the management and operation of data centres. The primary focus of this document is the processes necessary to deliver the expected level of resilience, availability, risk management, risk mitigation, capacity planning, security and resource and energy efficiency.
The secondary focus is on organization and data centre management to align the actual and future demands. Only processes specific for data centres are in the scope of this document.
Business processes like people management, financial management, etc. are out of scope.
- Standard70 pagesEnglish languagee-Library read for1 day
This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the piping system of unplasticized poly(vinyl chloride) (PVC-U) intended for soil and waste discharge applications (low and high temperature)
- above ground inside the building, or outside buildings fixed onto the wall; which is reflected in the marking by “B”;
- for both inside buildings and buried in ground within the building structure, which is reflected in the marking by “BD”. This intended use is only applicable for components with nominal outside diameters equal to or greater than 75 mm.
NOTE 1 Multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 1453-1[1].
PVC-U pipes, fittings and the system complying with this document are also suitable for the following purposes:
- ventilating part of the pipework in association with discharge applications;
- rainwater pipework within the building structure.
This document covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 26.
NOTE 2 EN 476[2] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to EN 1329-1 fully meet the EN 476 requirements.
- Standard48 pagesEnglish languagee-Library read for1 day
This document specifies a test method for the verification of the resistance to hydrostatic pressure of explosives for blasting and a test method for the verification of the resistance to hydrostatic pressure of explosives for boosters.
This document does not apply to black powder.
This document does not apply to explosive substances.
- Corrigendum2 pagesEnglish languagee-Library read for1 day
IEC 62196-1:2025 is applicable to EV plugs, EV socket-outlets, vehicle connectors, vehicle inlets, herein referred to as "accessories", and to cable assemblies for electric vehicles (EV) intended for use in conductive charging systems which incorporate control means, with a rated operating voltage not exceeding
- 690 V AC 50 Hz to 60 Hz, at a rated current not exceeding 250 A, and
- 1 500 V DC at a rated current not exceeding 800 A.
This fifth edition cancels and replaces the fourth edition published in 2022. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition of new tests for latching devices and retaining means;
b) inclusion of type 4 accessories.
- Standard117 pagesEnglish languagee-Library read for1 day
This document specifies definitions, principles of construction (but not dimensions) and design, requirements on performance and operation as well as methods for testing the performance of adjustable chemical dosing systems for conditioning water intended for human consumption inside buildings (see [1]) which are permanently connected to the mains supply.
- Standard18 pagesEnglish languagee-Library read for1 day
This document applies to portable residual current devices (PRCDs) for household and similar uses, consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection. They do not incorporate overcurrent protection. They are intended for single- and two-phase systems for rated currents not exceeding 16 A for rated voltages not exceeding 250 V AC. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream. PRCDs have a rated residual operating current not exceeding 0,03 A. The plug and socket-outlet parts of a PRCD are covered by the national standard of the country where the PRCD is placed on the market. This document applies to portable devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. PRCDs providing an additional function of detecting faults on the supply side with a defined behaviour in case of supply failures or miswiring (PRCD-S) are also covered by this document. PRCDs are not intended to be used as parts of fixed installations. Their connecting means can be plugs, socket-outlets, terminals or cords. NOTE 1 The requirements for PRCDs are in compliance with the general requirements of IEC 60755. PRCDs are essentially intended to be operated by ordinary persons and designed not to require maintenance. NOTE 2 An integral fuse is used, if necessary, for the relevant plug and socket-outlet system. The switching contacts of the PRCDs are not intended to provide isolation, as isolation can be ensured by disconnecting the plug. The requirements of this document apply for environmental conditions as defined in 7.1. Additional requirements can be necessary for PRCDs used in locations having more severe environmental conditions. PRCDs including batteries are not covered by this document. This document does not contain additional requirements for PRCDs without earthing contacts for which specific requirements can apply. This document can, however, be used as a guide for such devices which are intended to be used with Class II appliances only.
- Amendment11 pagesEnglish languagee-Library read for1 day
This document specifies a test method for the verification of the resistance to water of explosives for blasting and boosters.
NOTE This test method applies to situations where an explosive for blasting or a booster is subjected to high humidity and contact with water.
This document does not apply to black powder.
This document does not apply to explosive substances.
- Corrigendum2 pagesEnglish languagee-Library read for1 day
This document specifies requirements for the respiratory tubing and connectors used to convey respirable gases to a patient in the healthcare and homecare environments and provide a safe connection between the gas supply device and the patient interface. Respiratory tubing and connectors are mainly used for delivery of oxygen but can also be used for respirable air or oxygen/air mixtures and breathable medicinal gas mixtures such as oxygen/nitrous oxide or oxygen/helium mixtures. This document also specifies requirements for respiratory therapy extension tubing.
NOTE 1 The gas supply devices referred to in this document do not include anaesthetic machines/workstations and ventilators.
NOTE 2 This document does not cover breathing tubes for breathing systems. These are specified in ISO 5367.
This document is written following the format of ISO 18190, General standard for airways and related equipment. The requirements in this device-specific standard take precedence over any conflicting requirements in the General standard
- Standard20 pagesEnglish languagee-Library read for1 day
This document is applicable to calcium carbonate used for treatment of water intended for human consumption. It describes the characteristics of calcium carbonate and specifies the requirements and the corresponding test methods for calcium carbonate. It gives information on its use in water treatment.
- Standard14 pagesEnglish languagee-Library read for1 day
2021-12-07: This prAA includes CMs to prEN IEC (PR=75392)
DOW=DOR+48 months
- Amendment11 pagesEnglish languagee-Library read for1 day
IEC 62196-2:2025 applies to EV plugs, EV socket-outlets, vehicle connectors and vehicle inlets with pins and contact-tubes of standardized configurations, herein referred to as "accessories". These accessories have a nominal rated operating voltage not exceeding 480 V AC, 50 Hz to 60 Hz, and a rated current not exceeding 63 A three phase or 70 A single phase, for use in conductive charging of electric vehicles.
This fourth edition cancels and replaces the third edition published in 2022. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition of new tests for latching devices;
b) corrections to standard sheets.
- Standard88 pagesEnglish languagee-Library read for1 day
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Amendment5 pagesEnglish languagee-Library read for1 day
IEC 62841-3-11:2024 applies to transportable combined mitre and bench saws intended to be used with a toothed saw blade for cutting wood and analogous materials, plastics and nonferrous metals except magnesium with a saw blade diameter not exceeding 315 mm, which hereinafter is simply referred to as saw or tool.
This document does not apply to:
- saws intended to cut other metals, such as magnesium, steel and iron, or food;
- saws with an automatic feeding device;
- saws designed for use with abrasive wheels;
- saws designed for use with dado blades;
- single function bench or table saws;
- single function mitre saws;
- combined mitre and bench saws other than transportable.
NOTE 101 Transportable saws intended to cut ferrous metals will be covered by a future part of IEC 62841-3.
NOTE 102 Transportable tools designed for use with abrasive wheels are covered by IEC 62841-3-10:2015.
NOTE 103 Transportable table saws are covered by IEC 62841-3-1:2014.
NOTE 104 Transportable mitre saws are covered by IEC 62841-3-9:2020.
NOTE 105 In Europe (EN IEC 62841-3-11), the following additional NOTE applies:
NOTE Z101 Combined mitre and bench saws other than transportable are covered by EN 1870-3:2014.
This document is to be used in conjunction with IEC 62841-1:2014. This document supplements or modifies the corresponding clauses in IEC 62841-1, so as to convert it into the IEC Standard: Particular requirements for transportable combined mitre and bench saws.
- Standard58 pagesEnglish languagee-Library read for1 day
This document specifies the requirements for the rescue coupler for train sets compliant with the Technical Specification for Interoperability Locomotives and Passenger rolling stock (TSI Loc & Pas).
This document defines the rescue coupler foreseen to connect rescue vehicle equipped with draw hook, according to EN 15566 together with the train to be rescued equipped with Type 10 automatic coupler according to EN 16019.
- Standard20 pagesEnglish languagee-Library read for1 day
IEC 60669-2-4:2024 applies to manually operated general purpose isolating switches with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A, intended for household and similar fixed electrical installations, either indoors or outdoors. This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of the present edition with reference to the published IEC 60669-1:2017 Edition 4 with its amendments and references to clauses and tables;
b) introducing the values for isolating switches with ratings from 6 A to 13 A;
c) introducing a circuit motor load with a rated current not exceeding 10 A and a power factor not less than 0,6 in the scope;
d) modification of Table 1 and Table 5.
- Standard37 pagesEnglish languagee-Library read for1 day
- Amendment11 pagesEnglish languagee-Library read for1 day
This document specifies a procedure to determine the release of metals from metallic materials used in products intended to come into contact with drinking water.
The test can be used for three purposes:
a) To assess a material as a reference material for a new category of materials by metal release testing using the results of several investigations in different waters covering a broad range of water compositions;
b) To assess a material for an existing category for approval by way of metal release testing using the water defined in part 2, which exhibited the highest metal release when the reference material of the category was tested;
c) To obtain data on the interaction of local water with a material.
- Standard31 pagesEnglish languagee-Library read for1 day
This document specifies a procedure for obtaining a migration water to determine odour, flavour, colour and turbidity for products made from organic materials intended to come in contact with water for human consumption (drinking water) and used in piping and storage systems. Such products include pipes, tanks, reservoirs, fittings, ancillaries and their coatings both for site applied and factory-made products.
This document is applicable to products to be used under various conditions for the transport, storage and distribution of water intended for human consumption and raw water used for the manufacture of water intended for human consumption.
This document specifies a test method comprising a set of procedures. The use may be dependent on the relevant national regulations and/or the Commission Implementing Decision (EU) 2024/368.
- Standard27 pagesEnglish languagee-Library read for1 day
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Amendment5 pagesEnglish languagee-Library read for1 day
This document specifies a method for determining the total content (solvent extractable) of melamine in chemicals for the leather tanning industry.
This method requires the use of liquid chromatography (LC) with a triple quadrupole mass spectrometer (MS/MS), an ultraviolet (UV) detector, or diode array detector (DAD) to identify and quantify the melamine.
- Standard19 pagesEnglish languagee-Library read for1 day
This document provides guidance to the food industry, service providers and control laboratories on methodologies to be used for sample preparation, detection, identification and measurement of nano objects in inorganic food additives incorporated in food matrices.
Electron microscopy combined with energy dispersive X-ray spectroscopy (EM-EDX) and inductively coupled plasma mass spectrometry (ICP-MS) operated in single particle mode (spICP-MS) are the selected measurement methodologies to provide information on (i) the chemical composition and (ii) number-based particle size distribution of the nano-objects.
Special attention is given to the sample preparation, including matrix digestion, sample extraction and dilution steps to be used according to the combination of (i) the chemical nature of the food additive, (ii) the type of food matrix and (iii) the analytical technique of choice (EM-EDX or spICP-MS).
- Technical specification76 pagesEnglish languagee-Library read for1 day
IEC 62133-1:2026 specifies requirements and tests for the safe operation of portable sealed secondary nickel cells and batteries containing alkaline electrolyte, under intended use and reasonably foreseeable misuse. This second edition cancels and replaces the first edition of IEC 62133-1 published in 2017. It constitutes a technical revision.
This edition includes the following significant technical changes with respect to IEC 62133 1:2017:
a) removal of the definition "secondary battery";
b) removal of the definition "portable battery";
c) "removal of the definition "portable cell";
d) replacement of the single term "room temperature" with 20 °C ± 5 °C in 7.2.3;
e) modification of Figure 1.
- Standard24 pagesEnglish languagee-Library read for1 day
This document gives guidance on the labelling and information folder of potentially permanent magnet containing products in the context of information exchange between supply chain actors to improve recyclability of permanent magnets.
This document can be used by any natural or legal person that will place into the EU market products containing permanent magnets. The document is horizontal by nature and can potentially be applied to any type of permanent magnet containing product. Explicitly in scope are the product- and component groups mentioned in the introduction, as soon the total mass of permanent magnets is above the reporting level threshold specified 4.1 of this document.
The document specifies:
1. the graphical format, application, and location of the labels, so they are easily located, legible, and scannable in the end-of-life state of the products in a way that is suitable for products of different sizes and complexity;
2. the specifications of the data carrier, both in its physical format as placed on the product, and the accessibility, security, and verifiability of information;
3. the access rights of relevant stakeholders to information;
4. the information to be supplied regarding the location and composition of the permanent magnets;
5. the information to be supplied regarding adjacent materials like coatings and fixation features, including adhesives;
6. how to create step-by-step instructions for accessing and safely removing the permanent magnets, specifying the tools and technologies required, providing the recyclers a practically useful, unequivocal guide on how the disassembly of the magnets can be done most efficiently, and
7. the format of the data to be supplied as per the previous points 4. – 6.
Labelling is employed for products which encompass at least one component mentioned above or a singular magnet, including segmented magnets, which holds a total mass of magnetic material as described in Table 1. Other magnet-holding components within a product that fall below that threshold are exempt from declaration and labelling. The purpose of these thresholds is to establish a sensible balance between the efforts required by both the responsible entities for labelling, as well as the efforts by the dismantlers and recyclers, and the output of recycled material. By excluding potential scrap sources where the yield would not warrant the effort, the work can be simplified for both sides.
- Technical specification41 pagesEnglish languagee-Library read for1 day
This document provides guidance for users in the correct selection and usage of routinely available techniques for the determination of the aggregation and agglomeration state of nano-objects in powders, aerosols and suspensions. It provides guidance on measurands and measurement methods to use along with guidance on sample preparation.
- Technical specification61 pagesEnglish languagee-Library read for1 day
This document defines Product Category Rules (PCR) providing guidelines and rules for developing a type III environmental declaration (as in EN 15804:2012+A2:2019) for ceramic tiles produced by extrusion and dry-pressing techniques, mainly used for internal and/or external floorings and walls coverings, facade cladding.
The c-PCR:
- define the indicators to be declared, information to be provided and the way in which they are collated and reported;
- describe which stages of ceramic tiles’ life cycle are considered in the EPD and which processes are to be included in the life cycle stages;
- define rules for the development of scenarios;
- include the rules for calculating the Life Cycle Inventory and the Life Cycle Impact Assessment underlying the EPD, including the specification of the data quality to be applied;
- include the rules for reporting predetermined, environmental and health information, that is not covered by LCA for a ceramic tile, construction process and construction service where necessary;
- define the conditions under which ceramic tiles can be compared based on the information provided by EPD;
- include Annex A to Annex E in alignment to EN 15804:2012+A2:2019.
This PCR is intended to be used for cradle to grave and module D assessment.
- Standard26 pagesEnglish languagee-Library read for1 day
This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
The objective of this test is to ensure that the properties of the relay coil(s) are within the specified limits.
- Standard16 pagesEnglish languagee-Library read for1 day
This document specifies the dimensions of empty paper sacks and specifies a method of measuring those dimensions.
- Standard17 pagesEnglish languagee-Library read for1 day
This document specifies the requirements for an environmental management system that an organization can use to enhance its environmental performance. It is intended for use by an organization seeking to manage its environmental responsibilities in a systematic manner that contributes to the environmental pillar of sustainability.
This document helps an organization to achieve the intended outcomes of its environmental management system, which provide value for the environment, the organization itself and interested parties. The intended outcomes of an environmental management system include:
enhancing environmental performance;
meeting compliance obligations;
achieving environmental objectives.
This document is applicable to any organization, regardless of size, type or nature, and applies to the environmental aspects of its activities, products and services that the organization determines it can either control or influence considering a life cycle perspective. This document does not state specific environmental performance criteria.
This document can be used in whole or in part to systematically improve environmental management. Claims of conformity to this document, however, are not acceptable unless all its requirements are incorporated into an organization’s environmental management system and fulfilled without exclusion.
- Standard48 pagesEnglish languagee-Library read for1 day
Within the field of health informatics, the DICOM (digital imaging and communication in medicine) standard addresses the exchange of digital images, and information related to the production and management of those images, between both medical imaging equipment and systems concerned with the management and communication of that information, such as Picture Archiving anc Communication System (PACS), Hospital Information System (HIS) and Radiology Information System (RIS).
This document is equivalent to part 1 of DICOM. As such, it normatively describes the content of DICOM (Clause 6) and the requirements to make a claim of conformance (Clause 5).
The DICOM standard is applicable to diagnostic medical imaging as practiced in radiology, cardiology, pathology, dentistry, ophthalmology and related disciplines, and image-based therapies such as interventional radiology, radiotherapy and surgery. It is also applicable to a wide range of image and non-image related information exchanged in clinical, research, veterinary, and other medical environments.
- Standard26 pagesEnglish languagee-Library read for1 day
This document is a profile of CEN/TS 16614 series. It focuses on information relevant to feed passenger information services and excludes operational and fares information.
NeTEx is dedicated to the exchange of scheduled data (network, timetable and fare information) based on Transmodel V6 (EN 12986) and SIRI (CEN/TS 15531-4/5 and EN 15531-1/2/3) and supports information exchange of relevance to public transport services for passenger information and AVMS systems.
As for most data exchange standards, defining subsets of data and dedicated rules for some specific use case is of great help for implementers and for the overall interoperability. This subset is usually called profile and this profile targets passenger information as only use case.
- Technical specification272 pagesEnglish languagee-Library read for1 day
- Amendment11 pagesEnglish languagee-Library read for1 day
The present document specifies technical requirements, limits and test methods for Tilted Level Probing Radar (LPR) equipment using a downward tilted orientation of the LPR antenna in the three tilting ranges ±15°, ±30° and ±45° in relation to the strictly vertical downward direction and operating in the frequency range 75 GHz to 85 GHz in outdoor as well as indoor environments. Tilted LPR equipment in the scope of the present document consist of a combined transmitter and receiver and are equipped with an integral or dedicated antenna provided also by the equipment manufacturer. Equipment intended to be equipped with antennas from a third-party are not covered by the scope of the present document. Equipment exhibiting a receive only mode or a standby mode are also not covered by the scope of the present document. Furthermore, the present document is limited to tilted LPR equipment with FMCW modulation. Tilted LPR equipment and the related categorization is further specified in clause 4.2. NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.1] is given in Annex A.
- Standard56 pagesEnglish languagesale 15% off
- Standard56 pagesEnglish languagesale 15% off
- Standard57 pagesEnglish languagesale 15% off
- Standard57 pagesEnglish languagee-Library read for1 day
The present document provides an overview of the Recommendation ITU-T X.509 | ISO/IEC 9594-8 [i.3] based certificate profiles and the statements for EU Qualified Certificates specified in other parts of ETSI EN 319 412 ([i.4] to [i.7]). It specifies common data structures that are referenced from other parts of ETSI EN 319 412 ([i.4] to [i.7]). The profiles specified in this multi-part deliverable aim to support both Regulation (EU) No 910/2014 [i.9] and the use of certificates in a wider international context. Within the European context, it aims to support both EU Qualified Certificates and other forms of certificate.
- Standard18 pagesEnglish languagesale 15% off
- Standard18 pagesEnglish languagesale 15% off
- Standard18 pagesEnglish languagee-Library read for1 day
This document specifies requirements for the optical and geometrical properties of semi-finished blanks.
- Standard24 pagesEnglish languagee-Library read for1 day
The present document defines a dictionary of parameters that are commonly used in multiple TC LI specifications. Aside from defining a dictionary, the present document aims to provide technical means for other specifications to use. It is encouraged to use the present document in the development of new specifications. It is foreseen that regular maintenance of the present document is required. As such, release management requirements will be defined. Before accepting any new common parameter, the present document will provide a set of requirements the parameter has to comply to in order to become a common parameter.
- Standard47 pagesEnglish languagesale 15% off
- Technical specification47 pagesEnglish languagee-Library read for1 day
IEC 61757:2026 defines, classifies, and provides a framework of generic tests or measurement methods for characterizing and specifying fibre optic sensors, including their specific components and subassemblies. The requirements of this document apply to all related fibre optic sensor standards that are part of the IEC 61757 series. Other parts of the IEC 61757 series contain requirements that are specific to sensors that measure particular quantities, and to a particular style or variant of such a fibre optic sensor. This second edition cancels and replaces the first edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) expansion of the list of metrological parameters;
b) updates of the terms and definitions;
c) updates of the normative references and bibliography;
d) updates of the technical descriptions in Annex A.
- Standard47 pagesEnglish languagee-Library read for1 day
This document specifies procedures for detecting the presence of porosity in a protective paint system of any thickness on a steel or other metallic substrate. The procedures given in this document are based on methods using two different types of test equipment, the choice of equipment depending on the dry-film thickness. These procedures are only applicable to the testing of electrically non-conductive parts of a paint system.
The test methods specified are mainly intended for use with new coatings, but can also be used for coatings which have been in service for some time. In the latter case, it is important to bear in mind that the coating can have been penetrated by substances in contact with the coating during service.
- Standard17 pagesEnglish languagee-Library read for1 day
- Amendment39 pagesEnglish and French languagee-Library read for1 day
This document establishes a framework and specifies electronic fee collection (EFC) functions for the personalization process of on-board equipment (OBE) used for EFC.
The personalization process takes place within the domain of the entity that is responsible for the application in the OBE.
This document is applicable to the EFC interface, e.g. using dedicated short-range communication or integrated circuit(s) card, between the personalization equipment (PE) and OBE as shown in Figure 1.
This document does not cover the following:
whether the personalization functionality resides completely in the PE or whether this functionality instead resides in a central system, where the PE is more or less “transparent”;
the exact application command or message structures for the EFC personalization functionality (these are dependent on the communication media and are described in subsequent parts of the ISO 21719 series);
the test procedures for evaluation of an implementation for conformity to the requirements in this document;
setting-up of operating organizations (e.g. toll service provider, personalization agent, trusted third party).
NOTE Some of the issues listed above are subject to separate documents prepared by ISO/TC 204, CEN/TC 278 and the European Telecommunications Standards Institute – Electromagnetic compatibility and Radio Spectrum Matters (ETSI ERM).
- Standard16 pagesEnglish languagee-Library read for1 day
NeTEx is dedicated to the exchange of scheduled data (network, timetable and fare information). It is based on Transmodel V6.2 (EN 12896 series) and SIRI (CEN/TS 15531-4/-5 and EN 15531-1/-2/-3) and supports the exchange of information of relevance for passenger information about public transport services and also for running Automated Vehicle Monitoring Systems (AVMS).
NOTE Many NeTEx concepts are taken directly from Transmodel. The definitions and explanation of these concepts are extracted directly from the respective standard and reused in NeTEx, sometimes with adaptions in order to fit the NeTEx context.
Although the data exchanges targeted by NeTEx are predominantly oriented towards provisioning passenger information systems and AVMS with data from public transport scheduling systems, it is not restricted to this purpose. NeTEx can also provide an effective solution to many other use cases for transport data exchange.
- Technical specification1257 pagesEnglish languagee-Library read for1 day