This document specifies the requirements and test methods applicable to factory applied internal lining made of thermoplastic acid modified polyolefin (TMPO) for the heavy duty corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969. This document also applies to pipes with only socket and spigot ends coated with TMPO. Fittings and accessories are covered separately by EN 14901-2.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and test methods applicable to factory applied extruded polyethylene coatings for the external corrosion protection of ductile iron pipes according to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
This document is not applicable to ductile iron pipes protected with thin PE sleeve. Special works at site like drilling, tapping, etc. can influence the corrosion protection properties. Those job steps are intended to be included in the instructions of pipe saddle and accessory manufacturers and all other essential installation instructions. These instructions are not part of this document.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines the requirements and test methods for factory applied thermoplastic acid modified polyolefin (TMPO) coatings used for the protection of ductile iron fittings and accessories according to EN 545, EN 598, EN 969, EN 12842 and EN 14525:
-   conveying water (e.g. potable water, raw water, …) at operating temperature up to 50 °C; or
-   conveying waste water at operating temperature up to 45 °C; or
-   conveying gas at operating temperature up to 50 °C;
-   suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in D.2.3 of EN 545:2010.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder or liquid two-pack) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
-   conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
-   conveying waste water at operating temperature up to 45 °C excluding frost; or
-   conveying gas at operating temperature up to 50 °C;
-   suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in EN 545:2010, D.2.3.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 °C

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements and test methods applicable to factory applied cement mortar coatings for the external corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C, and for soil conditions according to Annex D.3 of EN 545:2006.
Special activities on site such as joint protection, tapping, clamping, etc. could affect the corrosion protection properties of the cement mortar coating. These operations should be covered in the laying instructions supplied by the manufacturers of pipes, clamps, house connection saddles, etc and any relevant users' procedures. Such instructions are not part of this European Standard.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard defines the requirements and test methods applicable to factory applied external polyurethane based coatings for heavy duty (Annex D.3 of EN 545:2002) corrosion protection of buried ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
This standard does not cover ductile iron pipes protected with zinc with a finishing layer of polyurethane.
This standard does not cover special activities on site such as tapping, clamping, etc., which could affect the corrosion protection properties of the polyurethane coating. These operations should be covered in the laying instructions supplied by manufacturers of clamps, house connection saddles, etc. and any relevant user procedures.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines the requirements and test methods applicable to factory applied cement mortar coatings for the external corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
NOTE   Coatings according to this document are suitable for soils of all common corrosion loads and trenchless applications.
Special activities on site such as joint protection, tapping, clamping, etc. could affect the corrosion protection properties of the cement mortar coating. These operations should be covered in the laying instructions supplied by the manufacturers of pipes, clamps, house connection saddles, etc. and any relevant users' procedures. Such instructions are not part of this document.

  • Draft
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder or liquid two-pack) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
-   conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
-   conveying waste water at operating temperature up to 45 °C excluding frost; or
-   conveying gas at operating temperature up to 50 °C;
-   suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in EN 545:2010, D.2.3.

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements and test methods applicable to factory applied extruded polyethylene coatings for the external corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
This European Standard does not cover ductile iron pipes protected with thin PE sleeve. Special works at site like drilling, tapping etc. may influence the corrosion protection properties. Those job steps shall be included in the instructions of pipe saddle and accessory manufacturers and all other essential installation instructions. These instructions are not part of this European Standard.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder or liquid two-pack) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
-   conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
-   conveying waste water at operating temperature up to 45 °C excluding frost; or
-   conveying gas at operating temperature up to 50 °C;
-   suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in EN 545:2010, D.2.3.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 °C.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder (P) or liquid two pack (L)) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
   conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
   conveying waste water at operating temperature up to 45 °C excluding frost; or
   conveying gas at operating temperature up to 50 °C;
   suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterised in annex D3 of EN 545:2002.

  • Standard
    17 pages
    English language
    sale 10% off