IEC 60851-3:2023 is available as IEC 60851-3:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60851-3: 2023 specifies the following test methods for winding wires: - Test 6: Elongation; - Test 7: Springiness; - Test 8: Flexibility and adherence; - Test 11: Resistance to abrasion; - Test 18: Heat bonding. For definitions, general notes on test methods and the complete series of test methods for winding wires, IEC 60851-1 applies. This document also provides recommended friction test methods in Annex B. This fourth edition cancels and replaces the third edition published in 2009, Amendment 1:2013 and Amendment 2:2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Clarification of the distance measurement for determining loss of adhesion in 6.6.3, 6.6.4 for fibre-covered wires and 6.6.5 for tape-wrapped wires.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-89:2023 specifies the requirements of enamelled round aluminium winding wire of class 200 with a sole coating based on polyesterimide resin, which can be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this standard is as follows: grade 1: 0,250 mm up to and including 1,600 mm; grade 2: 0,250 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD1:2013. This International Standard is to be used in conjunction with IEC 60317-0-3:2008, its Amendment 1 (2013) and its Amendment 2 (2019).

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-93: 2023 specifies the requirements of enamelled rectangular copper winding wire of class 220 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor dimensions covered by this standard is: width: min. 2,0 mm max. 25,0 mm; thickness: min. 0,80 mm max. 10,0 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified width/thickness ratio are given in IEC 60317-0-2. This International Standard is to be used in conjunction with IEC 60317-0-2:2020.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-27-3:2019 specifies the requirements of paper tape covered rectangular copper winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this document is - width: min. 2,0 mm max. 31,5 mm; - thickness: min. 0,80 mm max. 10,0 mm. The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5. Keywords: paper tape covered rectangular copper winding wires

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60851 specifies the following tests: - Test 5: Electrical resistance; - Test 13: Breakdown voltage; - Test 14: Continuity of insulation; - Test 19: Dielectric dissipation factor; - Test 23: Pin hole. For definitions, general notes on methods of test and the complete series of methods of test for winding wires, see IEC 60851-1.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60851 specifies the following methods of test for winding wires:
– Test 6: Elongation;
– Test 7: Springiness;
– Test 8: Flexibility and adherence;
– Test 11: Resistance to abrasion;
– Test 18: Heat bonding.
For definitions, general notes on methods of test and the complete series of methods of test for winding wires, see IEC 60851-1.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-80: 2019 specifies the requirements of enamelled rectangular copper winding wire of class 120 with a dual coating. The underlying coating is based on polyvinyl acetal resin, which can be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The second coating is a bonding layer based on a thermoplastic or thermosetting resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor dimensions covered by this document is: width: min. 2,00 mm max. 16,00 mm; thickness: min. 0,80 mm max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of nominal width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2:2019. Keywords: insulated wires used for windings

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the general requirements of enamelled round aluminium winding wires with or without a bonding layer. The range of nominal conductor diameters is given in the relevant specification sheet. When reference is made to a winding wire according to a standard of the IEC 60317 series mentioned under Clause 2, the following information is given in the description: - reference to IEC specification; - nominal conductor diameter, in millimetres; - grade.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-0-8:2019 is available as IEC 60317-0-8:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-0-8:2019 specifies the general requirements of polyester glass-fibre wound fused, unvarnished, or resin or varnish impregnated bare, or grade 1 or grade 2 or enamelled rectangular copper winding wires. The range of nominal conductor dimensions is given in 4.1 and in the relevant specification sheet. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - revision to the title of the standard indicating that the glass fibre covering is fused and unvarnished; - revision to subclause 3.2 adding winding wire requirements for the fibrous covering and a list of covering classifications; - revision to subclause 3.3 requirements for appearance; - revision to subclause 8.2, adherence test requirements. Keywords: insulated wires used for windings in electrical equipment

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of solderable enamelled round copper winding wire of class 180 with a sole coating based on polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this standard is:
– Grade 1: 0,020 mm up to and including 1,600 mm;
– Grade 2: 0,020 mm up to and including 1,600 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of solderable enamelled round copper winding wire of class 155 with a sole coating based on polyurethane resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this standard is:
– Grade 1: 0,018 mm up to and including 0,800 mm;
– Grade 2: 0,020 mm up to and including 0,800 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-84:2021 specifies the requirements of enamelled round copper winding wires of class 200 with a sole coating based on polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this document is as follows:  
Grade 1: 0,018 mm up to and including 3,150 mm;
Grade 2: 0,020 mm up to and including 5,000 mm;
Grade 3: 0,0250 mm up to and including 1,600 mm.  The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60851-1:2021 specifies the general notes on methods of test for winding wires. It also gives the definitions for terms used in IEC 60851 (all parts). A survey of the contents of IEC 60851-2 to IEC 60851-6 is given in Annex A. This third edition cancels and replaces the second edition published in 1996, and its amendment 1:2003 and amendment 2:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
revision to Clause 2 to update the list of normative references;
revision to 3.2 atmospheric conditions for testing;
addition to 3.2 with remarks concerning frequency and management of tests;
revision to Annex A to update the contents list of IEC 60851 series of tests.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-73:2018 specifies the requirements of enamelled rectangular aluminium winding wire of class 200 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which can be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor dimensions covered by this standard is: - width: min. 2,0 mm - max. 16,0 mm; - thickness: min. 0,80 mm - max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified width/thickness ratio are given in IEC 60317-0-9:2015. Keywords: insulated wires used for windings

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-74:2018 specifies the requirements of enamelled rectangular aluminium winding wire of class 180 with a sole coating based on polyesterimide resin, which can be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor dimensions covered by this standard is: - width: min. 2,0 mm - max. 16,0 mm; - thickness: min. 0,80 mm - max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified width/thickness ratio are given in IEC 60317-0-9:2015. Keywords: insulated wires used for windings

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60172:2020 is available as IEC 60172:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60172:2020 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. NOTE The data obtained according to this test procedure provide the designer and development engineer with information for the selection of winding wire for further evaluation of insulation systems and equipment tests. This fifth edition cancels and replaces the fourth edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - revision of 3.1, definition of thermal index; - revision of 3.3, time to failure; - revisions to 5.1.1 for clarity and to reduce the range wire size range to which the test applies; - revisions to 5.1.2 for tape wrapped round and enamelled or tape wrapped rectangular wire for clarity; - revision to Clause 9 to add the correlation coefficient, r to the report.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-0-7:2017 establishes general requirements for fully insulated (FIW) zero-defect enamelled round copper wires. The nominal conductor diameter range is given in the relevant technical specification. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - reduction in the number of grades of FIW from 3 through 9 to 4, 6 and 8 only; - reduction of the wire diameter range from (0,040 to 1,000) mm to (0,090 to 0,900) mm for several requirements; - revision of Clause 5 to delete the Table 2 resistance requirements; - revision of Clause 13 to clarify that breakdown is determined when a calculated minimum test voltage is reached, which can be less than 10 000 V; - expansion of Annex A to include requirements for FIW 3, 5, 7 and 9 and for all grades, wire diameters below 0,090 mm and above 0,900 mm. Keywords: insulated wires used for windings

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-56:2017 specifies the requirements of solderable fully insulated (FIW) zero-defect enamelled round copper wire, class 180, with a single coating based on polyurethane resin, which may be modified providing it retains its chemical identity and satisfies all the required technical specifications. The range of nominal conductor diameters of the wires covered by this standard is as follows: Grade of FIW 4, 6, 8: 0,090 mm up to and including 0,900 mm. Nominal conductor diameters are specified in IEC 60317-0-7. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Clause 1: revision of the scope, reducing the number of grades of FIW from 3 through 9 to 4, 6 and 8 only; - Clause 1: revision of the scope, reducing the wire diameter range from (0,040 to 1,600) mm to (0,090 to 0,900) mm; - addition of an informative annex for abrasion resistance requirements for grades FIW 3 to 9. Keywords: insulated wires used for windings in electrical equipment, enamelled round copper wire, class 180

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-60-1: 2020 specifies the requirements of polyester glass-fibre wound fused, unvarnished, bare or grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 155. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The range of nominal conductor dimensions covered by this document is: width: min. 2,0 mm max. 16,0 mm; thickness: min. 0,80 mm max. 5,60 mm.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-60-2:2020 specifies the requirements of polyester glass-fibre wound, resin or varnish impregnated, bare or grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. The range of nominal conductor dimensions covered by this document is: – width: min. 2,0 mm max. 16,0 mm; – thickness: min. 0,80 mm max. 5,60 mm. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-82: 2020 specifies the requirements of enamelled rectangular copper winding wires of class 200 with a sole coating based on polyesterimide resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor dimensions covered by this document is:  
width: min. 2,0 mm max. 16,0 mm;
thickness: min. 0,80 mm max. 5,60 mm.  Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified width/thickness ratio are given in IEC 60317-0-2.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-0-6:2020 is available as IEC 60317-0-6:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-0-6:2020 specifies the general requirements of glass-fibre wound resin or varnish impregnated, bare or enamelled, round copper winding wires. The range of nominal conductor diameters is given in the relevant specification sheet. This second edition cancels and replaces the first edition published in 2001 and Amendment 1:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - revision to 3.3, Appearance; - revision to Table 1, maximum overall diameter of grade 1 wire over single-glass fibre covering for nominal conductor diameters 1,600 mm - 5,000 mm; - revision to Table 2, maximum overall diameter of grade 1 wire over double-glass fibre covering for nominal conductor diameters 1,600 mm - 5,000 mm; clarification in Table 3 measurement of elongation as “minimum elongation %”.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-70-1:2020 specifies the requirements of polyester glass-fibre wound unvarnished and fused bare, grade 1 or grade 2 enamelled round copper winding wires, temperature index 155. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-70-2:2020 specifies the requirements of polyester glass-fibre wound resin/varnish impregnated bare, grade 1 or grade 2 enamelled round copper winding wires, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-0-2:2020 is available as IEC 60317-0-2:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-0-2:2020 specifies the general requirements of enamelled rectangular copper winding wires. The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet. This fourth edition cancels and replaces the third edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - revision to Clause 2 to add new normative references for specifications for copper rods; - revision to 3.1 to add a new definition for the term “bonding layer”; - revision to 3.2.1 to the conditions specified for tests to be carried out; - revision to 4.5 to add requirements for minimal, nomimal and maximal overall dimensions with a bonding layer; - revision to Clause 5 to reference specifications for rectangular and square copper rod; - revision to Clause 6 to take into account nominal proof strength; - revision to 8.2 to the adherence test requirement; - revision to Clause 18 to make reference to the relevant specification sheet.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-12:2020 is available as IEC 60317-12:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-12:2020 specifies the requirements of enamelled round copper winding wires of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. NOTE 2 Polyvinyl acetal is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral. The range of nominal conductor diameters covered by this document is: - Grade 1: 0,040 mm up to and including 2,500 mm; - Grade 2: 0,040 mm up to and including 5,000 mm; - Grade 3: 0,080 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This fourth edition of IEC 60317-12 cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - modification of the Scope; - addition of reference to transformer oil resistance test method in Clause 20.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-27-4:2020 specifies the requirements of paper tape covered rectangular aluminium winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this document is: – width: min. 2,00 mm max. 16,0 mm; – thickness: min. 0,80 mm max. 5,60 mm. The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-27-1:2020 specifies the requirements of paper tape covered round copper winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor diameters covered by this document is: – 0,500 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-62:2020 is available as IEC 60317-62:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-62:2020 specifies the requirements of polyester glass-fibre wound, silicone resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 200. The impregnating agent is a silicone containing resin or varnish.The range of nominal conductor dimensions covered by this document is: - width: min. 2,0 mm max. 16,0 mm; - thickness: min. 0,80 mm max. 5,60 mm. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - revision to the title of the standard to more precisely describe the construction of the wire; - revision to Clause 1, the scope of the standard, to provide more detail of the wire construction; - revision to 3.2.2, general winding wire requirements of the glass fibre covering.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-27-2:2020 specifies the requirements of paper tape covered round aluminium winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor diameters covered by this document is: - 0,500 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD1:2013. The paper tapes included in this document are restricted to those covered in IEC 60554-1 and IEC 60554-3-5.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-18:2020 is available as IEC 60317-18:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-18:2020 specifies the requirements of enamelled rectangular copper winding wires of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. NOTE 2 Polyvinyl acetate is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral. The range of nominal conductor dimensions covered by this document is: - width: min. 2,0 mm max. 31,5 mm; - thickness: min. 0,80 mm max. 10,0 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2. This fourth edition cancels and replaces the third edition published in 2004 and Amendment 1:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - modification of the Scope (Clause 1); - revision to thermal class designation from 105 to 120 in 3.2.2; - renaming of stretching test to adherence test, and modification to the requirements in 8.2; - revision to the cut-through requirement in Clause 10.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-25:2020 is available as IEC 60317-25:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-25:2020 specifies the requirements of enamelled round aluminium winding wires of class 200 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this document is: - Grade 1: 0,250 mm up to and including 3,150 mm; - Grade 2: 0,250 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD1:2013. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - new 3.2.2 containing general notes on winding wire, formerly a part of the Scope; - revision to Clause 11 to take into account intermediate nominal conductor diameters; - revision to Clause 7 to indicate that the springiness test is inappropriate. - revision to Clause 16 to specify only the percentage of extractable matter and the minimum retained dielectric breakdown voltage.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-17:2020 is available as IEC 60317-17:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60317-17:2020 specifies the requirements of enamelled rectangular copper winding wires of class 105 with a sole coating based on polyvinyl acetal resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. NOTE 2 Polyvinyl acetate is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral. The range of nominal conductor dimensions covered by this document is: - width: min. 2,0 mm max. 31,5 mm; - thickness: min. 0,80 mm max. 10,00 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio of width/thickness are given in IEC 60317-0-2. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - modification of the Scope (Clause 1); - renaming of stretching test to adherence test and a modification of the requirement in 8.2.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-61:2020 is available as IEC 60317-61:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-61:2020 specifies the requirements of polyester glass-fibre wound, resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 180. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The range of nominal conductor dimensions covered by this document is: - width: min. 2,0 mm max. 16,0 mm; - thickness: min. 0,80 mm max. 5,60 mm. The specified combinations of width and thickness as well as the specified width/thickness ratio are according to IEC 60317-0-8. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - revision of the title of the standard; - revision to Clause 1, Scope; - revision to the descriptions of grades of thickness of polyester glass-fibre coverings in 3.2.2.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-0-4:2020 is available as IEC 60317-0-4:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-0-4:2020 specifies general requirements of glass-fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire.The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - addition of dimensional requirements for grade 1 enamelled wire in Table 4; - addition of dielectric breakdown requirements for grade 1 enamelled wire in Table 7. - addition of requirement for the adherence test in 8.2.1 and 8.2.2.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-72:2020 is available as IEC 60317-72:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-72: 2020 specifies the requirements of polyester glass-fibre wound silicone resin/varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 200. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The nominal conductor diameters are specified in IEC 60317-0-10:2017, Clause 4. This second edition cancels and replaces the first edition published in 2017. The document 55/1768/CDV, circulated to the National Committees as Amendment 1, led to the publication of this new edition. This edition includes the following significant technical changes with respect to the previous edition: - modification of the title; - revision to the Scope; - revision to 3.2.2.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-71:2020 is available as IEC 60317-71:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-71:2020 specifies the requirements of polyester glass-fibre wound resin/varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 180. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The nominal conductor diameters are specified in IEC 60317-0-10:2017, Clause 4. This second edition cancels and replaces the first edition published in 2017. The document 55/1767/CDV, circulated to the National Committees as Amendment 1, led to the publication of this new edition. This edition includes the following significant technical changes with respect to the previous edition: - modification of the title; - revision to the Scope; - revision to 3.2.2.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-0-10:2017 specifies the general requirements of polyester glass-fibre wound fused, unvarnished, or resin or varnish impregnated bare, grade 1 or grade 2 or enamelled round copper winding wires. The range of nominal conductor dimensions is given in Table 1, Table 2, Table A.1 and Table A.2. Keywords: insulated wires used for windings

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-67: 2017 specifies the requirements of enamelled rectangular aluminium winding wire of class 105 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The range of nominal conductor dimensions covered by this standard is:       Minimum  Maximum    Width  2,0 mm  16,0 mm    Thickness  0,80 mm  5,60 mm      Wires of grade 1 and grade 2 are included in this part of IEC 60317 and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specific ratio width/thickness are given in IEC 60317-0-9. This publication is to be read in conjunction with IEC 60317-0-9:2015. Keywords: insulated wires used for windings in electrical equipment, class 105

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-68: 2017 specifies the requirements of enamelled rectangular aluminium winding wire of class 120 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The range of nominal conductor dimensions covered by this standard is       Minimum  Maximum    Width  2,0 mm  16,0 mm    Thickness  0,80 mm  5,60 mm      Wires of grade 1 and grade 2 are included in this part of IEC 60317 and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specific ratio width/thickness are given in IEC 60317-0-9:2015. Keywords: insulated wires used for windings in electrical equipment, class 120

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-69:2017(E) specifies the requirements of enamelled rectangular aluminium winding wire of class 220 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin. The range of nominal conductor dimensions covered by this standard is:       Minimum  Maximum    Width  2,0 mm  16,0 mm    Thickness  0,80 mm  5,60 mm      Wires of grade 1 and grade 2 are included in this part of IEC 60317 and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specific ratio width/thickness are given in IEC 60317. This publication is to be read in conjunction with IEC 60317-0-9:2015 Keywords: insulated wires used for windings in electrical equipment, class 220

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60851-4:2016 specifies the following chemical properties tests: - Test 12: Resistance to solvents; - Test 16: Resistance to refrigerants; - Test 17: Solderability; - Test 20: Resistance to transformer oil. For definitions, general notes on methods of test and the complete series of methods of test for winding wires see IEC 60851-1. This third edition cancels and replaces the second edition published in 1996, Amendment 1:1997 and Amendment 2:2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - revision of Test 16: Resistance to refrigerants; - revision of Test 17: Solderability; - new Annex A for alternative refrigerants to monochlorodifluoromethane (R 22). Keywords: chemical properties tests, test for winding wires

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-59:2015 specifies the requirements of enamelled round copper winding wire of class 240 with a single coating of polyamide-imide resin. The range of nominal conductor diameters covered by this part of IEC 60317 is: - grade 1: 0,180 mm up to and including 1,600 mm; - grade 2: 0,180 mm up to and including 1,600 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. Keywords: insulated wires used for windings, enamelled round copper winding wire of class 240

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day