IEC 61076-8-105:2023 applies to free and fixed 2-pole snap locking rectangular power connectors with plastic housing with rated current 63 A and rated voltage up to 400 V. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements, test methods.

  • Standard
    59 pages
    English and French language
    sale 15% off

IEC 61076-3-106:2023 constitutes a detail product specification for 8-way connectors for data transmission with frequencies up to 600 MHz.
It covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65/IP67 rating according to IEC 60529, for use in industrial environments.
The housings cover a variety of different locking mechanisms according to this document and a variety of different mounting configurations and termination types which are detailed in the IEC 60603-7 series.
Common mating configurations for all variants are defined in IEC 60603-7. The mating dimensions for the housings under Clause 3 allow the mating conditions under IEC 60603-7 to be fulfilled.
The fully assembled variants (connectors) described in this document incorporate fully compliant IEC 60603-7 series fixed and free connectors.

  • Standard
    74 pages
    English and French language
    sale 15% off

IEC 61076-8-106: 2023 applies to free and fixed, 2-pole push-pull and snap locking power rectangular connectors with fuses, with rated voltage of 400 V DC and rated current of 16 A. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements, and test methods.
Connectors according to this document are connectors with breaking capacity (CBC) according to IEC 61984 which are mainly used in DC power conduction, in the field of electrical and electronic equipment.

  • Standard
    65 pages
    English and French language
    sale 15% off

IEC 61076-2-115:2023 describes free and fixed 12P shielded circular connectors with 2 A rated current, rated voltage up to and including 50 V AC/DC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    68 pages
    English and French language
    sale 15% off

IEC 63171-7:2023 covers shielded free and fixed circular connectors with 4 ways up to 7 ways for power and data transmission and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively.
The connectors described in this document are either equipped with an M12 screw-locking mechanism (styles with M12 in the name) or a quick-locking push-pull mechanism with a size derived from that (styles with P12 in the name) or both mechanisms combined (styles with C12 in the name). For the sake of simplicity, the connectors' size is denoted as "size 12" in this document.
This document provides multiple mating interfaces each of which is associated with a coding preventing the mating of incompatible male and female connectors. These codings are referred to as "Type x", where "x" is represented by a Roman numeral.
For all codings, two ways and the additional shield pin, which is intended to be connected to the cable screen, support differential data transmission with frequencies up to 600 MHz by meeting the requirements of Category B, as defined in IEC 63171.

  • Standard
    33 pages
    English language
    sale 15% off

IEC 61076-8-107:2023 describes free and fixed rectangular connectors with:
- 2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 200 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked, and IPXXB on both plug and receptacle parts when unmated;
- hereinafter referred to as a connector, for use in electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    75 pages
    English and French language
    sale 15% off

IEC 61076-8-109:2023 describes free and fixed rectangular connectors with:
- 2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 130 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked and IPXXB on both plug, and receptacle parts when unmated;
- hereinafter referred to as a connector, for use in electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    75 pages
    English and French language
    sale 15% off

IEC 61076-8-108:2023 describes free and fixed rectangular connectors with:
- 2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 250 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked, and IPXXB on both plug and receptacle parts when unmated, hereinafter referred to as a connector, for use in electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    74 pages
    English and French language
    sale 15% off

IEC 61076-8-104:2023 describes free and fixed 2-pole circular power connectors with 40 A rated current, rated voltage up to and including 50 V AC/DC, and push-pull locking IP65/IP67 metal housings (hereinafter referred to as connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    67 pages
    English and French language
    sale 15% off

IEC 61076-8-103:2023 describes free and fixed 2-pole power (1P+N) plus PE circular connectors with 20 A rated current, rated voltage up to and including 300 V AC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    68 pages
    English and French language
    sale 15% off

IEC 61076-3-126:2023 covers 5-pole rectangular connectors for electric power supply up to 16 A per pole. These connectors consist of fixed and free connectors, both either rewirable or non-rewirable. This document employs the general function principles of the push-pull connector housing system described in IEC 61076‑3‑117 with IP65/IP67 degree of protection according to IEC 60529 for harsh applications.
Male connectors have pin contacts with square cross-section with 1 mm side. Connectors according to this document are without breaking capacity COC according to IEC 61984, therefore they are not intended to be engaged or disengaged in normal use when live or under load.

  • Standard
    84 pages
    English and French language
    sale 15% off

IEC 61076-2-116:2022 specifies circular connectors size 15 with bayonet-locking, with up to 3 power contacts with rated insulation voltage up to 630 V AC/DC and rated current up to 20 A, plus PE, and up to 3 auxiliary contacts with rated insulation voltage up to 63 V AC/DC and rated current up to 10 A, that are typically used for industrial power supply and power applications, such as the feeding and control of 3-phase asynchronous motors. These connectors consist of both fixed and free connectors either rewireable or non-rewireable, with bayonet-locking. Male connectors have round contacts, either power or signal, Ø1,6 mm.

  • Standard
    85 pages
    English and French language
    sale 15% off

IEC 60352-6:2022 This part of IEC 60352 is applicable to insulation piercing connections made with stranded wires and tinsel wires, insulated flat conductors and flat flexible circuitries for use in electrical and electronic equipment. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this document is to: determine the suitability of insulation piercing connections under specified mechanical, electrical, and atmospheric conditions; provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.

  • Standard
    70 pages
    English and French language
    sale 15% off

IEC 63171-4:2022 covers shielded and unshielded free and fixed multimedia connectors (MMC) for data transmission with frequencies up to and above 3 000 MHz for shielded and up to 600 MHz for unshielded connectors, both with current-carrying capacity with up to 8 ways. It specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications, respectively. The form factor of these connectors allows their use for cable sharing with TOs (Telecommunications Outlet) for structured cabling. This document covers type 4 connectors. Each part of this series has the associated type number equal to the number of the part in the series. All connectors in the IEC 63171 series are deemed to provide the same functions as defined in IEC 63171, using different mechanical interfaces. The shielded and unshielded connectors are interoperable for their internal transmission performance and can be exchanged. The shielded version has improved EMC and coupling properties. The connectors are intended to be used for Single Pair Ethernet (SPE) according, but not restricted to the following IEEE standards: 10Base-T1 (IEEE 802.3cg), 100Base-T1 (IEEE 802.3bw), 1000Base-T1 (IEEE 802.3bp), Multi-Gig Base-T1 (IEEE 802.3ch) and optionally with Power over Data line (PoDL) power supply according to IEEE 802.3bu. The contents of the corrigendum 1 (2023-08) have been included in this copy.

  • Standard
    27 pages
    English language
    sale 15% off

IEC 63171-5:2022 refers to International Standards for test and measurement, environmental testing as well as solderless connections. This part of IEC 63171 describes 2-way shielded or unshielded circular connectors with IP65/IP67 M8 or M12 locking, typically used for balanced single-pair data transmission with frequencies up to 600 MHz and with current-carrying capacity up to 4 A, for use in areas with harsh environmental conditions. These connectors consist of fixed and free connectors, either rewirable or non-rewirable. Male connectors have square cross-section contacts.

  • Standard
    65 pages
    English and French language
    sale 15% off

L'IEC 60512-27-200:2022 est avant tout destiné à être utilisé pour les essais d’intégrité des signaux et de qualité de la transmission jusqu’à 2 000 MHz des types de connecteurs à 8 voies couverts par la série IEC 60603-7 (IEC 60603‑7‑81), conformément à la méthode d’essai des connecteurs de l’IEC 60512‑28‑100. Le présent document couvre les connecteurs d’essai ainsi que les dispositifs d’essai à référence indirecte utilisés pour mesurer l’intégrité des signaux et la qualité de la transmission selon les exigences de la série IEC 60603-7 concernant les types de connecteurs à 8 voies définis dans les normes publiées suivantes: - IEC 60603‑7‑2 - IEC 60603‑7‑3 - IEC 60603‑7‑4 - IEC 60603‑7‑5 - IEC 60603‑7‑41 - IEC 60603‑7‑51 - IEC 60603‑7‑81 Le présent document fournit des informations supplémentaires sur les connecteurs d’essai ainsi que sur les dispositifs d’essai utilisés pour les mesures de performance des connecteurs conformément aux normes de méthode d’essai qui concernent ces connecteurs: - IEC 60512‑26‑100 - IEC 60512‑27‑100 - IEC 60512‑28‑100 Cette première édition annule et la CEI/PAS 60512-27-200, parue en 2018.

  • Standard
    59 pages
    English and French language
    sale 15% off

IEC 60512-99-002:2022 est disponible sous forme de IEC 60512-99-002:2022 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.  L’IEC 60512 est utilisée pour évaluer des connecteurs relevant du domaine d’application du SC 48B, qui sont utilisés dans les câblages de communication à paires torsadées permettant une alimentation à distance, tels que les câbles à paires symétriques conformes à la classe D de l’ISO/IEC 11801‑1 ou à une classe supérieure, à l’appui de la norme IEEE 802.3btTM (Power over Ethernet (alimentation électrique par câble Ethernet), prenant en charge jusqu’à 90 W provenant de l’équipement de source d’alimentation). L’objet du présent document est de détailler un programme d’essai permettant de déterminer l’aptitude des jeux de connecteurs à supporter au moins 100 manœuvres mécaniques avec charge électrique lorsqu’un courant électrique traverse les connecteurs conformément à l’IEC 60512‑9‑3 pendant la séparation (désaccouplement). Cette deuxième édition annule et remplace la première édition publiée en 2019. Cette édition constitue une révision technique. Cette édition comprend les modifications techniques importantes suivantes par rapport à l’édition précédente : Le groupe d’essai UEL a été révisé en ce qui concerne l’ordre des phases de test, les sévérités des tests et les exigences.

  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 63171-6:2021 covers 2-way and 4-way (data/power), shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications. This second edition cancels and replaces the first edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Mating conditions changed, see Figure 2, Figure 4, Figure 13, Figure 15, Figure 19 and Figure 21. b) Voltage proof requirement added, 2 250 V DC, see 5.7.2. c) Mechanical shock requirement added, see 5.7.6 (the requirement itself already was specified indirectly by Ed1 due to the specification of the test EP3 of Table 14 which is still identical to Ed1). d) Styles added, 6P-M8CI and 6J-M8CI, see Table 1.

  • Standard
    48 pages
    English language
    sale 15% off

IEC 61076-2-011:2021 describes the bayonet coupling interface of circular connectors that are typically used for industrial process measurement and control. These connectors consist of fixed and free connectors either rewireable or non-rewireable, with bayonet-coupling. These connectors may have glass to metal seal inserts. They have male or female contacts and are deemed to be intermateable with corresponding free connectors produced according to this document. Male connectors have round contacts Ø 0,6 mm, Ø 0,76 mm, Ø 0,8 mm and Ø 1,0 mm.
Different codings prevent the mating of these individually coded fixed connectors (and consequently of individually coded free connectors deemed to couple with them) to other interfaces and cross-mating between the different codings. However, the styles and interface dimensions, except for the coupling mechanism, are as given in 4.3 of IEC 61076-2- 101:2012 and 4.3.1 of IEC 61076-2-109:2014.
The male type B12 circular connectors are interoperable with the female type B12 connector of the same coding and ways. The female type B12 connectors are interoperable with the male type B12 and M12 (threaded screw coupling) connector of the same coding and ways.

  • Standard
    24 pages
    English and French language
    sale 15% off

IEC 63171-2:2021 covers 2-way, shielded or unshielded, free and fixed connectors for data transmission up to 600 MHz, with current-carrying capacity, known as Type 2. It specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. The form factor of these connectors allows their use for cable sharing with already installed TO’s for structured cabling. The overall performance of the transmission channel in such case has to be evaluated. Intermateable and interoperable versions for circular connector for sealed applications including this connector are described in IEC 63171-5. The shielded and unshielded connectors are interoperable for their internal transmission performance and can be exchanged. The shielded version has improved alien crosstalk and coupling attenuation properties.

  • Standard
    21 pages
    English language
    sale 15% off

IEC 61076-2-010:2021 specifies circular connectors with a push-pull locking mechanism of a size derived from, and thus being compatible with M12 screw-locking connectors (free connectors with screw-locking according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 or IEC 61076-2-113 are compatible with push‑pull fixed interfaces according to this document) and with mating interfaces according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 (except codings E in general and coding F for inner push-pull) or IEC 61076-2-113.
A fixed connector with push-pull locking according to this document is intermateable with a correspondingly coded free connector with M12 screw-locking according to any of the above mentioned standards.
M12 is the dimension of the thread of the screw-locking mechanism of circular connectors with M12 screw-locking.
IEC 61076-2-012 defines another inner push-pull for fixed female connectors which is however not compatible to the inner push-pull defined in this document. Annex C shows the different styles of female free connectors to extend male free connectors.
This document covers both:
a) power connectors with current ratings up to 16 A and voltage ratings up to 630 V, typically used for power supply and power applications in industrial premises, and
b) connectors for data and signal transmission with frequencies up to 500 MHz.
These connectors consist of both, fixed and free connectors, either rewirable or non-rewirable, with M12 push-pull locking as explained above. Male connectors have round contacts from Ø 0,6 mm up to Ø 1,5 mm. In addition, the push-pull mechanisms consist of 2 different push-pull designs:
c) An outer push-pull for male and female fixed connector, where the locking groove is placed onto the outer cylindric surface of the housing. The outer push-pull for female fixed connectors is made for 2 different types of male connectors. It has locking means for both types on its outer surface.
For design and dimensions see 5.3.2 and 5.3.3.
d) An inner push-pull for female fixed connectors and for male free connectors, where the locking means are placed onto the inner cylindric surface of the housing.
For design and dimensions see 5.3.4.
The different codings provided by IEC 61076-2 series detail specifications mentioned within this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces, covered by other standards and the cross-mating between the different codings provided by any other IEC 61076-2 series detail specification mentioned within this document.

  • Standard
    101 pages
    English and French language
    sale 15% off

IEC 61076-3-122:2021 covers 8-way, shielded, free and fixed rectangular connectors for I/O and data transmission with frequencies up to 500 MHz. It is intended to specify the common dimensions, mechanical, electrical and environmental characteristics and tests for this family of connectors.
Connectors complying with this document provide an ingress protection level of IP20; however, they are particularly suited for industrial environments with a high level of vibration.
There are two classes of connectors defined in this document, indicated by "class A" and "class B" which are distinguished by some electrical and mechanical characteristics to meet the particular sets of requirements of some industrial applications.
Class A meets the requirements defined in Ed.1 of this document.
With the two classes A and B, the two codings Type I and II, and the two sets of transmission requirements according to the component categories Cat 5 and Cat 6A as defined in ISO/IEC 11801-1, this document specifies 2 × 2 × 2 = 8 variants.
All connectors covered by this document feature a current-carrying capacity beyond the minimum requirement of 0,75 A per pin for an ambient temperature of 60° C as defined in ISO/IEC 11801 1.
This second edition cancels and replaces the first edition published in 2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Title modified.
b) Introduction of two sets of requirements for connectors of "class A" and "class B" where class A matches the requirements defined in the previous edition.
c) Definition of new performance requirements for frequencies up to 500 MHz in addition to the performance requirements up to 100 MHz provided with the previous edition.
d) Re-structuring to reflect the commonalities of and differences between connector Type I and Type II.
e) Revision of drawings to clarify some dimensions.
e) The derating diagram has been corrected to align it with the upper limiting temperature in the climatic category, with no reduction of performance for the target applications.

  • Standard
    65 pages
    English and French language
    sale 15% off

IEC 63171:2021 couvre les fiches et les embases écrantées et non écrantées, circulaires ou rectangulaires, pour transmission de données sur une seule paire symétrique avec courant admissible. Il spécifie les caractéristiques mécaniques, électriques et de transmission communes et les exigences environnementales, ainsi que les spécifications d’essai exigées, issues de la série de normes IEC 63171. Le présent document ne décrit pas une interface d’accouplement spécifique. Des spécifications particulières d’interfaces d’accouplement conformes au présent document peuvent être trouvées dans la famille de normes de spécifications particulières IEC 63171-X (type X). Les connecteurs écrantés ou non d’un même type sont interopérables en ce qui concerne leurs performances de transmission et peuvent être échangés. La version écrantée présente des propriétés d’affaiblissement de couplage et de diaphonie exogène améliorées.

  • Standard
    70 pages
    English and French language
    sale 15% off

IEC 60352-7:2020 is available as IEC 60352-7:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60352-7:2020 is applicable to spring clamp connections made with stripped wire without further preparation:
- solid conductors of 0,32 mm to 3,7 mm nominal diameter (0,08 mm2 to 10 mm2 cross‑section), or
- stranded conductors of 0,08 mm2 to 10 mm2 cross-section, or
- flexible conductors of 0,08 mm2 to 10 mm2 cross-section,
according to IEC 60228 or IEC 60189-3 for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this document is to determine the suitability of spring clamp connections under specified mechanical, electrical and atmospheric conditions. This second edition cancels and replaces the first edition of IEC 60352-7, published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) correction of the two flow charts in Figure 6 and Figure 7,
b) split the content into more clauses for better separation between full test schedule and basic test schedule,
c) relocating the content of former Clause 6 Practical guidance into an informative Annex A, as now common in the IEC 60352 series for solderless connections,
d) clarification on conductor types with reference to classes defined in IEC 60228.

  • Standard
    30 pages
    English language
    sale 15% off
  • Standard
    65 pages
    English and French language
    sale 15% off

IEC 60603-7:2020 est disponible sous forme de IEC 60603-7:2020 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.  L'IEC 60603-7:2020 couvre les connecteurs 8 voies, non couverts, libres et fixes et vise à spécifier les dimensions communes (dimensions d’interface), les caractéristiques mécaniques, électriques et environnementales et les tests pour la famille des connecteurs IEC 60603-7-x. Ces connecteurs sont intermates (selon le niveau 2 de l’IEC 61076-1) et interopérables avec d’autres connecteurs de la série IEC 60603-7. Cette quatrième édition annule et remplace la troisième édition, publiée en 2008, son amendement 1:2011 et son amendement 2:2019. Il s’agit d’une révision technique. Cette édition comprend les changements techniques importants suivants par rapport à l’édition précédente : - Révision des définitions de l’intermiabilité et de l’interopérabilité; a ajouté de nouvelles définitions. - Ligne de dimension corrigée pour la dimension AZ2 de la figure 5. - Ligne de dimension corrigée pour la dimension F1 de la figure A.1. - Révision de la référence à l’ISO/IEC 11801 à l’ISO/IEC 11801-1. - Ajout d’une température limite inférieure et de définitions de température limitantes supérieures. - Tableau 1 révisé au tableau 8 de sorte que l’ordre de colonne est des dimensions minimales-nominales-maximales (ordre croissant). - Tableau corrigé 7 : Catégorie climatique et valeurs de température supérieures à 90 °C (pour être compatible avec le graphique de la figure 10 et de la note 1 de la figure 10). - Révision du libellé en 8.2, résistance aux contacts, pour clarification. - Figure 11 et figure 12 révisées et le libellé de la clé ci-dessous pour clarification. - Suppression des phrases en vertu de la figure de l’Introduction. - Ajout de l’annexe E.

  • Standard
    107 pages
    English and French language
    sale 15% off

IEC 61076-2-114:2020 describes circular connectors with M8 screw locking typically used for data and power transmissions in industrial applications. These connectors consist of fixed and free connectors that are either rewireable or non-rewireable. Data transmission performance is for Category 5 up to 100 MHz.
Two coded versions, identified as D-coded and P-coded, are provided that differ by their pin size and optionally by number of poles, hence by the function provided for field applications.
Male connectors have round contacts Ø 0,8 mm for D-coded, and Ø 1 mm for P-coded connectors.
The coding provided by this document prevents the mating of accordingly coded male or female connectors to any other similarly sized interfaces covered by other standards.

  • Standard
    93 pages
    English and French language
    sale 15% off

IEC 61076-2-012:2020 specifies circular connectors with an inner push‑pull locking mechanism of a size derived from and thus being compatible with M12 screw‑locking connectors and with mating interfaces according to IEC 61076‑2‑101, IEC 61076‑2‑109, IEC 61076‑2‑111 and IEC 61076‑2‑113.
A female fixed connector with inner push-pull locking according to this document is intermateable with a correspondingly coded male free connector with M12 screw-locking according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 or IEC 61076-2-113.
This document covers both:
a) power connectors with current ratings up to 16 A and voltage ratings up to 630 V, typically used for power supply of electrical equipment used in industrial premises, and
b) connectors for data and signal transmission with frequencies up to 500 MHz.
These connectors consist of both fixed and free connectors, either rewirable or non‑rewirable, with M12 inner push‑pull locking as explained above. Male connectors have round contacts from Ø0,6 mm up to Ø1,5 mm.
This document covers various types of connectors identified by their "codings" with different contact arrangement, not mutually interchangeable.
The design of the inner push‑pull mechanism prevents the unintended mating of the male inner push‑pull free connector with the female connector with M12 screw‑locking even for identical coding.
Some styles of free connectors with female contacts covered in this document are equipped with both inner and outer push-pull locking for intermateability also with correspondingly coded male fixed or free connectors according to IEC 61076-2-010.

  • Standard
    121 pages
    English and French language
    sale 15% off

IEC 60352-5:2020 s’applique aux connexions press-in sans soudure pour utilisation dans les équipements et composants électriques et électroniques. La connexion press-in consiste en une terminaison ayant une zone de press-in appropriée qui est insérée dans un trou d’une planche. Les informations sur les matériaux et les données provenant de l’expérience industrielle sont incluses en plus des procédures d’essai pour fournir des connexions électriques stables dans des conditions environnementales spécifiques. L’objet du présent document est de déterminer la pertinence des connexions de presse dans des conditions mécaniques, électriques et atmosphériques telles que spécifiées par le fabricant de la terminaison presse-in et de fournir un moyen de comparer les résultats des essais lorsque les outils utilisés pour effectuer les connexions sont de conceptions ou de fabrications différentes. Cette cinquième édition annule et remplace la quatrième édition publiée en 2012. Cette édition constitue une révision technique. Cette édition comprend les changements importants suivants par rapport à l’édition précédente : a) révision du domaine d’application en supprimant dans le premier alinéa l’expression "…dans les équipements de télécommunication et les systèmes électroniques employant des techniques similaires" et en la remplaçant par l’expression "…dans les équipements et composants électriques et électroniques"; b) ajout des termes "carte", "trou" et "carte métallique", et des définitions associées, pour stipuler que les bornes pour connexion insérée à force sont utilisées sur des cartes non imprimées fabriquées dans différents matériaux; c) modifications éditoriales clarifiant la différence entre le programme d’essais de qualification et le programme d’essais d’application; d) modification de la limite supérieure d’épaisseur de cuivre du trou métallisé, afin de refléter les tendances réelles du marché et les pratiques de fabrication; e) suppression de l’essai de courbure, celui-ci ciblant plus spécifiquement des applications de la technologie d’insertion à force qui ne sont plus très répandues; f) ajout de graphiques visant à documenter la force d’insertion et la force d’extraction, car cela constitue une pratique d’essai courante et donne des informations supplémentaires sur les performances mécaniques de la zone de contact; g) réduction du nombre de spécimens exigés, car un lot d’échantillons d’essai avait été ignoré dans le schéma d’essais précédent; h) nouvelle formulation en 4.5 pour les bornes fissurées ou pliées; i) ajout de la Figure 7b pour représenter les points de connexion pour la mesure de la tension et du courant lorsque la borne pour connexion insérée à force ne dépasse pas de la face inférieure de la carte.

  • Standard
    34 pages
    English language
    sale 15% off
  • Standard
    69 pages
    English and French language
    sale 15% off

IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with: – appropriately designed ID terminations; – wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter; – wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area; for use in electrical and electronic equipment and components. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail. The purpose of this document is: – to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions; – to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture. This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Transferred Clauses 9 to 13 into Annex A (informative). b) The figures were re-drawn for clarity.

  • Standard
    85 pages
    English and French language
    sale 15% off

IEC 60512-9-5:2020 est disponible sous forme de IEC 60512-9-5:2020 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.  L'IEC 60512-9-5:2020 est utilisée pour les essais des connecteurs ou des connexions sans soudure du domaine d’activité du comité d’études 48, lorsque la spécification particulière de produit l’exige. Elle peut également être utilisée pour des dispositifs similaires lorsqu’une spécification particulière de produit l'indique. L’objet du présent document est de définir une méthode normalisée pour soumettre les connexions sans soudure à une contrainte thermique appliquée au moyen d’une charge en courant de façon cyclique. Cette deuxième édition annule et remplace la première édition, parue en 2010, dont elle constitue une révision technique. La présente édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: - introduction de la méthode B pour fournir une alternative avec des durées d'activation et de désactivation ajustables pour les produits de masse thermique plus élevée. L'ancienne méthode devient la méthode A. - ajout d'une introduction pour présenter cette revision.

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 61076-8-102:2020 décrit les connecteurs blindés étanches à 2 pôles ou 3 pôles pour la transmission de puissance et à 2 pôles pour la transmission de données avec boîtier plastique (par la suite appelés connecteurs) pour équipements électriques et électroniques, et notamment leurs dimensions hors-tout, les dimensions des interfaces, les caractéristiques techniques, les exigences en matière de performances et les méthodes d’essai. Le présent document s’applique à tous les connecteurs dont les exigences en matière d’étanchéité et de blindage répondent au présent document pour une tension assignée inférieure ou égale à 750 V en courant alternatif ou 1 000 V en courant continu avec un courant assigné de 150 A, pour des applications dans le domaine des équipements électriques et électroniques.

  • Standard
    80 pages
    English and French language
    sale 15% off

IEC 63171-1:2020 covers two-way, shielded or unshielded, free and fixed connectors for data transmission with frequencies up to 600 MHz and with current carrying capacity up to 2,0 A at 60 °C. It is intended to specify the common dimensions, mechanical, electrical, signal integrity, environmental characteristics, reliability specifications and corresponding tests for these connectors.

  • Standard
    63 pages
    English and French language
    sale 15% off

IEC 61076-8-101:2020 décrit les connecteurs blindés étanches à 2 pôles ou 3 pôles pour la transmission de puissance et à 2 pôles pour la transmission de données avec boîtier plastique (par la suite appelés connecteurs) pour équipements électriques et électroniques, et notamment leurs dimensions hors-tout, les dimensions des interfaces, les caractéristiques techniques, les exigences en matière de performances et les méthodes d’essai. Le présent document s’applique à tous les connecteurs dont les exigences en matière d’étanchéité et de blindage répondent au présent document pour une tension assignée inférieure ou égale à 750 V en courant alternatif ou 1 000 V en courant continu avec un courant assigné de 40 A, dans le domaine des équipements électriques et électroniques.

  • Standard
    80 pages
    English and French language
    sale 15% off

IEC 61076-8-100:2020 décrit les connecteurs blindés étanches à 2 pôles ou 3 pôles pour la transmission de puissance et à 2 pôles pour la transmission de données avec boîtier plastique (par la suite appelés connecteurs) pour équipements électriques et électroniques, et notamment leurs dimensions hors-tout, les dimensions des interfaces, les caractéristiques techniques, les exigences en matière de performances et les méthodes d’essai. Le présent document s’applique à tous les connecteurs dont les exigences en matière d’étanchéité et de blindage répondent au présent document pour une tension assignée inférieure ou égale à 750 V en courant alternatif ou 1 000 V en courant continu avec un courant assigné de 20 A, pour des applications dans le domaine des équipements électriques et électroniques.

  • Standard
    80 pages
    English and French language
    sale 15% off

IEC 60352-3:2020 est applicable aux connexions CAD qui sont accessibles pour les essais et les mesures conformes aux Articles 6 à 8 et qui sont composées de: – contacts CAD accessibles de conception appropriée, – fils à conducteurs cylindriques massifs de diamètre nominal 0,25 mm à 3,6 mm, – fils à conducteurs divisés de section 0,05 mm2 à 10 mm2, pour l’utilisation dans les équipements et composants électriques et électroniques. Des informations sur les matières et des résultats dus à l’expérience industrielle y sont inclus en plus des méthodes d’essai pour assurer des connexions électriquement stables dans les conditions d’environnement prescrites. Il y a différentes conceptions et matières utilisées pour les contacts CAD accessibles. C’est pourquoi seuls les paramètres fondamentaux du contact sont spécifiés, tandis que les exigences des performances du fil et de la connexion terminée sont définies dans tous les détails. Le présent document a pour objet de: – déterminer la conformité des connexions CAD accessibles dans des conditions méca-niques, électriques et atmosphériques spécifiées; – fournir un moyen de comparaison des résultats d’essai quand les outils utilisés pour faire les connexions, le cas échéant, sont de conceptions ou de fabrications diffé-rentes. Cette deuxième édition annule et remplace la première édition parue en 1993. Cette édi-tion constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édi-tion précédente: a) Paragraphe 7.2.2: il réduit la limite de la durée de la perturbation de contact à 1 µs. b) Paragraphe 7.2.3: il réduit la limite de la durée de la perturbation de contact à 1 µs. c) Les Articles 9 à 13 ont été transférés à l’Annexe A (informative). d) Les figures ont été révisées pour plus de clarté.

  • Standard
    81 pages
    English and French language
    sale 15% off

IEC 63171-6:2020, covers 2-way and 4-way (data/power) shielded free and fixed connectors for data transmission with frequencies up to 600 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively.
This document specifies several properties overlapping with specifications in the IEC 63171 series which have been drafted later. In case of conflict the specifications within this document prevail.
Keywords: Connectors for data transmission

  • Standard
    98 pages
    English and French language
    sale 15% off

IEC 60512-28-100:2019 is available as IEC 60512-28-100:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60512-28-100:2019 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC 61076-1, IEC 61076-2, and IEC 61076-3 standards for connecting hardware applications up to 2 000 MHz. It is also suitable for testing lower frequency connectors, however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector. The above list of connector series of standards does not preclude referencing this document in other connector manufacturer’s specifications or published standards. Test procedures provided herein are:
- insertion loss, test 28a;
- return loss, test 28b;
- near-end crosstalk (NEXT) test 28c;
- far-end crosstalk (FEXT), test 28d;
- transverse conversion loss (TCL), test 28f;
- transverse conversion transfer loss (TCTL), test 28g.
Other test procedures referenced herein are:
- transfer impedance (ZT), see IEC 60512-26-100, test 26e.
- for coupling attenuation (aC), see IEC 62153 4 12.
This second edition cancels and replaces the first edition, issued in 2013, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- The title is revised from 1 000 MHz to 2 000 MHz to reflect the range of frequencies which may be tested.
- All tables and requirements have been revised up to 2 000 MHz.
Key words: Connectors, Signal Integrity Tests

  • Standard
    90 pages
    English and French language
    sale 15% off

IEC 61076-3-123:2019. covers hybrid rectangular connectors with a 3 poles 16 A electric portion for power supply and a duplex fibre optic connector type LC portion for data transmission.
These connectors consist of fixed and free connectors, either rewirable or non-rewirable (for both portions) and use the rectangular push-pull housing described in IEC 61076-3-117 with IP65/IP67 degree of protection, for harsh applications.
The mating dimensions of such housings allow fulfilling the performance class Category I according to IEC 61753-1-3 in regards to the fibre optic portion of the connector with the exception of the operating temperature range which is –25 °C/+70 °C.
The electric portion may have different rated insulation voltages. Male connectors have 3 electric round contacts Ø1,6 mm, with 16 A rated current.
The fibre optic portion provides data transmission by using the common mating configurations for all variants of the type LC duplex fibre optic connectors as defined in IEC 61754-20, for dedicated fibre types and fibre termination technology covered therein.
The different codings provided by this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces covered by other standards and the cross-mating between the different codings provided by this document.
Key words: Rectangular Connectors, Hybrid Connectors, Power Supply and Fiber Optic Data Transmission.

  • Standard
    89 pages
    English and French language
    sale 15% off

IEC 60512-11-1:2019 est utilisée, lorsque la spécification particulière (de produit) l'exige, pour soumettre à l'essai des connecteurs qui entrent dans le domaine d'application du comité d'études 48 de l'IEC. Cet essai peut aussi être utilisé sur des dispositifs similaires (c'est-à-dire lorsque les mécanismes de dégradation sont les mêmes) lorsqu'une spécification particulière (de produit) l'indique. L'objet de cet essai est de définir une méthode d'essai normalisée pour évaluer l'aptitude des connecteurs à fonctionner de manière spécifiée dans un environnement spécifié qui pourrait être rencontré dans des conditions normales d'utilisation, y compris le stockage. Le présent document fournit une méthode d'essai composite normalisée pour déterminer l'aptitude des connecteurs soumis à des conditions d'environnement consistant en une séquence de contraintes climatiques comportant température, humidité, et si cela est exigé, basse pression. Mots clés: connecteurs, Essais climatiques

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 61076-3-124:2019 covers 10-way, shielded, free and fixed rectangular connectors for data transmission with frequencies up to 500 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively.
Connectors covered in this document are provided in three codings that differ only for the position of the polarization key and keyway, in view of their differently intended use:
Connectors type A and C are intended for 10/100 Mbit/s as well as for 1/ 2,5 / 5 /10 Gbit/s Ethernet communication.
Connectors type B are intended for all other non-Ethernet applications such as signalling, serial or other industrial bus communication systems.
- A-coding: The 45° cut corner used as polarization key and keyway system is located on the lower left corner of the male fixed connector (viewed from mating face) (Figures 5a, 5b).
- B-coding: The 45° cut corner is located on the upper left corner of the male fixed connector (Figures 5c, 5d).
- C-coding: There are two 45° corners located at the upper left and lower left corner (Figures 5e, 5f).
- In this document, the three codings, A, B, and C are designated as “Type A”, “Type B” and “Type C”.
Key words: Rectangular Connectors, 10 Way Shielded, Free and Fixed Connectors, I/O and Data Transmission, Frequencies up to 500 MHz
The contents of the corrigendum of March 2020 have been included in this copy.

  • Standard
    88 pages
    English and French language
    sale 15% off

IEC 60512-99-002:2019 is used for testing connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class D (or better), balanced cabling in support of IEEE Std 802.3bt™, (PoE Plus – Power over Ethernet Plus).
The object of this document is to detail a test schedule to determine the ability of pairs of connectors to withstand a sequence of tests with a total of 100 engagements and separations. The electrical current is passed through the connectors during the separation (unmating) step only, in accordance with IEC 60512-9-3.
Keywords: Connectors, Engaging and Separating connectors

  • Standard
    24 pages
    English and French language
    sale 15% off

IEC 60512-23-3:2018 is available as IEC 60512-23-3:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60512-23-3:2018. defines a standard test method for measuring the shielding effectiveness SE of a shielded connector, or of a connector not provided with integral shield once fitted with a shielding accessory and terminated with a screened cable. The complete assembly has a continuous 360° shielding capability throughout its length. This test method can be applied to shielded connectors and to connector accessories with shielding capability. The following different connector designs can be tested:
- circular connectors;
- rectangular connectors;
- connectors for printed boards;
- connector shielding accessories.
This test method utilizes the principle that the intrinsic shielding property of the connector/ accessory/cable assembly is its surface transfer impedance ZT which can be expressed as the longitudinal voltage inside the shield, relative to the current flow on the outside shell. This test is also suitable for measuring the shielding effectiveness of a connector fitted with triaxial contacts terminated with shielded, twisted pair cables, as used in data bus systems. This second edition cancels and replaces the first edition, published in 2000. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) an introduction has been added to provide some guidance to this document in view of concurrent test method 23g in the same family;
b) the frequency range for which this test method is considered reliable moved from 1 GHz to 3 GHz, to be consistent with Figure 7 (unchanged) and current industry practice and need;
c) update to IEC 62153-4-6:2017 of former normative reference IEC 60096-4-1:1990, withdrawn and incorrect (should have been IEC 61196-1:1995, also withdrawn);
d) update to current subclause numbers of IEC 62153-4-6:2017 what were the previous subclause numbers referenced in IEC 61196-1:1995 (wrongly attributed to IEC 60096-4-1:1990). For immediate understanding the title of these subclauses has been added;
e) alignment of title to the current scope of SC 48B (connectors) and inclusion of electrical equipment as target application of said connectors (per current scope of TC 48) and explicit reference to the method – line injection – for the measurement of transfer impedance;
f) symbols SE for shielding effectiveness and ZT for surface transfer impedance added throughout the document;
g) list of connectors to which the test method is applicable – previously in 3.1 – moved in scope;
h) former name of AECMA organization changed to the current ASD-STAN;
i) “specimen” used instead of “sample” throughout the document;
j) clarification in the title of what transfer impedance is described in Table 3 and editorial improvement of the same;
k) “dielectric constant” changed into the updated term “relative permittivity”;
l) added a note to warn about the fact that this test method requires in 6.6 a TDR with more stringent rise time of less than 100 ps than the value of less than 350 ps specified both in IEC 62153-4-6 and in EN 50289-1-6 for the similar line injection method applied to screened cables, whereas test 23g of IEC 60512-23-7 specifies for the same purpose a TDR with a rise time of less than 200 ps;
m) adoption of term “connector housing” [IEV 581-27-10] instead of “shell” to address the connector accessory providing the shielding;
n) title “Transfer impedance ZT [Ω]” added to the ordinate axis on the left side of double log diagram of Figure 7;
o) explanatory note to clarify the conversion formula for SE from ZT added.
Key words: Connectors, Screening and Filtering Tests, Shielding Effectiveness

  • Standard
    30 pages
    English and French language
    sale 15% off

IEC 60512-1:2018 is available as IEC 60512-1:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60512-1:2018 is intended to be used as a basis for tests and measurements specifications for electrical connectors. It provides guidance and reference for tests and measurements within the IEC 60512 series. It includes the description and the practice of the various phases of tests and measurements (preparation, tests and measurements, requirements, documentation), in addition to basic terms and definitions applicable to any part of the IEC 60512 series. This standard shall be used in conjunction with IEC 60512-1-101 and relevant part(s) of series IEC 60512. Part 60512-1-100 provides the list of the existing test and measuring methods published within series IEC 60512. Detail tests and measurements specifications are applicable to electrical connectors and their components (e.g. connector inserts, connector housings, locking mechanisms, contacts and terminations) within the scope of technical committee 48. They may also be used for similar devices when specified in a detail product specification. Detail tests and measurements specifications are used in conjunction with detail product specifications which prescribe the tests to be used, the required degree of severity for each of them and the permissible performance limits. The detail product specification also specifies the deviations in procedures, which may be required when applying a test to the type of connector or its component under consideration, and it further specifies any special procedures which may be required. This fifth edition cancels and replaces the fourth edition, published in 2001. It constitutes a technical revision. This edition includes the following main technical changes with respect to the previous edition:
– in Clause 3, only terms relating to the testing are defined, and IEC 61076-1 is referred to for terms of connectors.
– Clause 4 (Numbering of tests and measurement specification) is added.
– Subclause 5.1.2 (Calibration) is added.
– in Clause 6 (Test), test procedure follows IEC 60068-1.
Key words: Connectors, Test Specification

  • Standard
    28 pages
    English and French language
    sale 15% off

IEC 62946-01:2018(E) covers 8-way shielded connectors, and is intended to specify the common dimensions, mechanical, electrical and environmental characteristics and tests for the family of IEC 62946-01 connectors.
These connectors are intermateable and interoperable with other IEC 62946 series connectors.
Key words: Connectors, Rectangular, 8-way, Shielded Free and Fixed High density, Data Transmission
The contents of the corrigendum of March 2020 have been included in this copy.

  • Standard
    29 pages
    English language
    sale 15% off

IEC 60512-8-3:2018 Lorsque la spécification particulière (de produit) l’exige, la présente partie de l'IEC 60512 est utilisée pour les essais des connecteurs qui entrent dans le domaine d’application du comité d’études 48 de l'IEC. Elle peut aussi être utilisée pour des dispositifs similaires, lorsqu’une spécification particulière (de produit) le spécifie. L’objet de ce document est de détailler une méthode d’essai normalisée pour évaluer la robustesse de l’ergot d’activation d’un mécanisme d’accouplement ou de relâchement de la connexion. Cette deuxième édition annule et remplace la première édition parue en 2011. La présente édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: La présente édition reflète l'IEC 60512-1-101, Spécification particulière cadre et le paragraphe 4.2 (Préparation du spécimen) est amélioré. Mots clés: connecteurs, Essais de charge statique (embases)

  • Standard
    17 pages
    English and French language
    sale 15% off

IEC 60512-15-2:2018 La présente partie de l'IEC 60512 est utilisée, lorsque la spécification particulière (de produit) l’exige, pour les essais des connecteurs qui entrent dans le domaine d’application du comité d’études 48. Elle peut aussi être utilisée pour des dispositifs similaires lorsqu’une spécification particulière (de produit) le spécifie. L’objet de ce document est de détailler une méthode d’essai normalisée pour évaluer l’efficacité du système de retenue d’un isolant de connecteur à l'intérieur d'un boîtier de connecteur à résister aux forces axiales susceptibles d'être rencontrées au cours d’une utilisation normale, c'est-à-dire les forces d'insertion et d'extraction les plus élevées dans/en provenance d'un connecteur d'accouplement correspondant, l'isolant de connecteur n'étant pas détaché du boîtier de connecteur. La méthode d’essai détaillée dans le présent document accompagne celle détaillée dans l'IEC 60512-15-3. Cette deuxième édition annule et remplace la première édition, parue en 2008, dont elle constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: La méthode d'essai B (méthode de la pression) appropriée aux essais du connecteur hermétique a été ajoutée. La présente édition reflète l'IEC 60512-1-101, Spécification particulière cadre. Mots clés: connecteurs, essais des connecteurs, Rétention de l'isolant

  • Standard
    16 pages
    English and French language
    sale 15% off

IEC/PAS 61076-3-126:2018(E) covers rectangular IP65/IP67 connectors with 5 poles for electric power supply up to 16 A. These connectors consist of fixed and free connectors, either rewirable or non- rewirable (for both portions). It uses the general function principles of the push-pull connector housing system described in IEC 61076-3-117 with IP65/IP67 degree of protection according to IEC 60529 for harsh applications.
Male connectors have 5 square 1 mm electric contacts, with 16 A rated current. Connectors according this document are without breaking capacity COC according to IEC 61984, therefore they are not intended to be engaged or disengaged in normal use when live or under load, if not otherwise specified by the manufacturer.

  • Technical specification
    42 pages
    English language
    sale 15% off