Accidental actions can be subdivided into accidental actions with a natural cause and accidental actions due to human activities. This document applies to reliability based and risk informed decision making for the design and assessment of structures subject to accidental actions due to human activities. However, fires and human-made earthquakes are not included. The information presented in this document is intended for buildings and civil engineering works, regardless of the nature of their application and the use or combination of materials. The application of this document can require additional elements or elaboration in special cases. This document is intended to serve as a basis for those committees that are responsible for the task of preparing International Standards, national standards or codes of practice in accordance with given objectives and context in a particular country. Where relevant, it can also be applied directly to specific cases. This document describes how the principles of risk and reliability can be utilized to support decisions related to the design and assessment of structures subject to accidental actions and systems involving structures during all the phases of their service life. For the general principles of risk informed design and assessment, it is intended that ISO 2394 be considered. The application of this document necessitates knowledge beyond that which it contains. It is the responsibility of the user to ensure that this knowledge is available and applied.

  • Standard
    108 pages
    English language
    sale 15% off

ISO 12494:2017 describes the general principles of determining ice load on structures of the types listed in this clause. In cases where a certain structure is not directly covered by this or another standard or recommendation, designers can use the intentions of this document. However, it is the user's responsibility to carefully consider the applicability of this document to the structure in question. The practical use of all data in this document is based upon certain knowledge of the site of the structure. Information about the degree of "normal" icing amounts (= ice classes) for the site in question is used. For many areas, however, no information is available. Even in such cases, this document can be useful because local meteorologists or other experienced persons should be able to, on the safe side, estimate a proper ice class. Using such an estimate in the structural design will result in a much safer structure than designing without any considerations for problems due to ice. CAUTION It is extremely important to design for some ice instead of no ice, and then the question of whether the amount of ice was correct is of less importance. In particular, the action of wind can be increased considerably due to both increased exposed area and increased drag coefficient. ISO 12494:2017 is intended for use in determining ice mass and wind load on the iced structure for the following types of structure: - masts; - towers; - antennas and antenna structures; - cables, stays, guy ropes, etc.; - rope ways (cable railways); - structures for ski-lifts; - buildings or parts of them exposed to potential icing; - towers for special types of construction such as transmission lines, wind turbines, etc. Atmospheric icing on electrical overhead lines is covered by IEC (International Electrotechnical Commission) standards. This document is intended to be used in conjunction with ISO 2394. NOTE Some typical types of structure are mentioned, but other types can also be considered by designers by thinking in terms of which type of structure is sensitive to unforeseen ice, and act thereafter. Also, in many cases, only parts of structures are to be designed for ice loads because they are more vulnerable to unforeseen ice than is the whole structure. Even if electrical overhead lines are covered by IEC standards, designers can use this document for the mast structures to overhead lines (which are not covered by IEC standards) if they so wish.

  • Standard
    58 pages
    English language
    sale 15% off

ISO 3010:2017 (including both the super structure and foundation) and other structures. ISO 3010:2017 is not applicable to certain structures, such as bridges, dams, geotechnical works and tunnels, although some of the principles can be referred to for the seismic design of those structures. ISO 3010:2017 is not applicable to nuclear power plants, since these are dealt with separately in other International Standards. In regions where the seismic hazard is low, methods of design for structural integrity can be used in lieu of methods based on a consideration of seismic actions. ISO 3010:2017 is not a legally binding and enforceable code. It can be viewed as a source document that is utilized in the development of codes of practice by the competent authority responsible for issuing structural design regulations. NOTE 1 This document has been prepared mainly for new engineered structures. The principles are, however, applicable to developing appropriate prescriptive rules for non-engineered structures (see Annex N). The principles could also be applied to evaluating seismic actions on existing structures. NOTE 2 Other structures include self-supporting structures other than buildings that carry gravity loads and are required to resist seismic actions. These structures include seismic force-resisting systems similar to those in buildings, such as a trussed tower or a pipe rack, or systems very different from those in buildings, such as a liquid storage tank or a chimney. Additional examples include structures found at chemical plants, mines, power plants, harbours, amusement parks and civil infrastructure facilities. NOTE 3 The level of seismic hazard that would be considered low depends not only on the seismicity of the region but also on other factors, including types of construction, traditional practices, etc. Methods of design for structural integrity include nominal design horizontal forces (such as an equivalent static loading determined from a simplified equivalent static analysis) which provide a measure of protection against seismic actions.

  • Standard
    60 pages
    English language
    sale 15% off

ISO/TR 12930:2014 provides seismic design examples for geotechnical works based on ISO 23469:2005 in order to demonstrate how to use this ISO standard. The design examples are intended to provide guidance to experienced practicing engineers and code writers. Geotechnical works include buried structures (e.g. buried tunnels, box culverts, pipelines, and underground storage facilities), foundations (e.g. shallow and deep foundations, and underground diaphragm walls), retaining walls (e.g. soil retaining and quay walls), pile-supported wharves and piers, earth structures (e.g. earth and rock fill dams and embankments), gravity dams, tanks, landfill and waste sites.

  • Technical report
    215 pages
    English language
    sale 15% off

ISO 4355:2013 specifies methods for the determination of snow load on roofs. It can serve as a basis for the development of national codes for the determination of snow load on roofs. National codes should supply statistical data of the snow load on ground in the form of zone maps, tables, or formulae. The shape coefficients presented in ISO 4355:2013 are prepared for design application, and can thus be directly adopted for use in national codes, unless justification for other values is available. For determining the snow loads on roofs of unusual shapes or shapes not covered by ISO 4355:2013 or in national standards, it is advised that special studies be undertaken. These can include testing of scale models in a wind tunnel or water flume, especially equipped for reproducing accumulation phenomena, and should include methods of accounting for the local meteorological statistics. Examples of numerical methods, scale model studies, and accompanying statistical analysis methods are described in ISO 4355:2013 (Annex G). The annexes of ISO 4355:2013 describing methods for determining the characteristic snow load on the ground, exposure coefficient, thermal coefficient, and loads on snow fences are for information only as a consequence of the limited amount of documentation and available scientific results. In some regions, single winters with unusual weather conditions can cause severe load conditions not taken into account by ISO 4355:2013. Specification of standard procedures and instrumentation for measurements is not dealt with in ISo 4355:2013.

  • Standard
    40 pages
    English language
    sale 15% off

ISO 13033:2013 establishes the means to derive seismic actions on nonstructural components and systems (NSCS) supported by or attached to new or existing buildings. It also provides procedures for the verification of NSCS seismic capacities. NSCS include architectural elements, mechanical and electrical systems, and building contents. ISO 13033:2013 is not a legally binding and enforceable code. It is a source document that is utilized in the development of codes of practice by the competent authority responsible for issuing structural design regulations. It is intended for application by regional and national standards committees when preparing standards for the seismic performance of NSCS. ISO 13033:2013 does not specifically cover industrial facilities, including nuclear power plants, since these are dealt with separately in other International Standards. However, the principles in ISO 13033:2013 can be appropriate for the derivation of seismic actions for NSCS in such facilities.

  • Standard
    43 pages
    English language
    sale 15% off

ISO 4354:2008 describes the actions of wind on structures and specifies methods of calculating characteristic values of wind loads for use in designing buildings, towers, chimneys, bridges and other structures, as well as their components and appendages. The loads are suitable for use in conjunction with ISO 2394 and other International Standards concerned with wind loads. In particular, ISO 4354:2008 facilitates the conversion between peak- and mean-wind-speed methodologies and covers the three main storm types, synoptic winds, thunderstorms and tropical cyclones (hurricanes and typhoons). ISO 4354:2008 provides the basic methods from which to determine wind loading analytically through the determination of design pressures or orthogonal along-wind and cross-wind forces and moments for structures of simple shape and wind directionality effects, and through wind tunnel or computational determinations of pressure, forces and moments for structures with complex shapes and wind directionality effects resulting in complex combinations of forces and moments. Two methods of analytical determination of design wind loads are given, one based on a peak velocity and the other on a mean velocity.

  • Standard
    68 pages
    English language
    sale 15% off

ISO 21650:2007 describes the principles of determining the wave and current actions on structures of the following types in the coastal zone and estuaries: breakwaters: rubble mound breakwaters; vertical and composite breakwaters; wave screens; floating breakwaters; coastal dykes; seawalls; cylindrical structures (jetties, dolphins, lighthouses, pipelines etc.). ISO 21650:2007 does not include breakwater layout for harbours, layout of structures to manage sediment transport, scour and beach stability or the response of flexible dynamic structures, except vortex induced vibrations. Design will be performed at different levels of detail: concepts; feasibility; detailed design. ISO 21650:2007 is aimed at serving the detailed design.

  • Standard
    127 pages
    English language
    sale 15% off

ISO 23469:2005 provides guidelines for specifying seismic actions for designing geotechnical works, including buried structures (e.g. buried tunnels, box culverts, pipelines, and underground storage facilities), foundations (e.g. shallow and deep foundations, and underground diaphragm walls), retaining walls (e.g. soil retaining and quay walls), pile-supported wharves and piers, earth structures (e.g. earth and rockfill dams and embankments), gravity dams, landfill and waste sites. The guidelines provided in ISO 23469:2005 are general enough to be applicable for both new and existing geotechnical works. However, for use in practice, procedures more specific to existing geotechnical works can be needed, such as those described for existing structures in ISO 13822.

  • Standard
    85 pages
    English language
    sale 15% off

Deals with pressure conditions in hoppers, bunkers, bins and silos constructed using normal structural engineering materials. For the purposes of definition, the term silo is used to represent all forms of storage. All parameters given shall be agreed with the client and written into all contract documents. Design of the silo shall be checked if any of the criteria given are changed.

  • Standard
    15 pages
    English language
    sale 15% off
  • Standard
    16 pages
    French language
    sale 15% off
  • Standard
    16 pages
    French language
    sale 15% off

Defines the actions due to the self-weight of structures, non-structural elements and stored materials and gives the numerical values of their densities. These actions are to be determined by multiplying the densities by the gravitational acceleration and by the actual volume. The actions caused by the weight of the earth placed on the structures are similarly calculated.

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off
  • Standard
    56 pages
    English language
    sale 15% off
  • Standard
    31 pages
    English language
    sale 15% off
  • Standard
    32 pages
    French language
    sale 15% off
  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    47 pages
    French language
    sale 15% off
  • Standard
    47 pages
    French language
    sale 15% off

Presents basic methods for the determination of seismic actions on structures. Specifies methods of evaluating seismic actions for the earthquake-resistant design of buildings, towers, chimneys, and similar structures. Most of the principles are applicable also to stuctures such as bridges, dams, harbour installations, tunnels, fuel storage tanks, chemical plants, conventional power plants excluding nuclear power plants.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off

Is intended to be a guideline for code-writers. Can be applied to the determination of unfavourable characteristic values of temperature difference due to temperature climatic actions which are taken into account in static analysis of structures for which the variation of temperature within the cross-section can be treated as linear. Is not applicable to massive structures (dams, retaining walls, tunnels, bridge piers ets.). For condideration of such structures it may be necessary to take into account non-linear distribution ot temperature through the body of the massive structural elements.

  • Technical report
    28 pages
    English language
    sale 15% off
  • Technical report
    28 pages
    French language
    sale 15% off
  • Technical report
    28 pages
    French language
    sale 15% off

Indicates the lowest nominal values of loads due to use and occupancy in residential and public buildings. These values are the most unfavourable values for certain conditions of normal use of a building. Gives also the lowest nominal values of uniformly distributed loads, the reduction of uniformly distributed loads, and horizontal loads.

  • Standard
    3 pages
    English language
    sale 15% off
  • Standard
    3 pages
    French language
    sale 15% off
  • Standard
    3 pages
    French language
    sale 15% off

Specifies methods of determining imposed floor loads to be adopted for certain functions of production buildings and warehouses, for design-calculation purposes. Indicates definitions, establishing of imposed floor loads, minimum imposed floor loads and reduction of imposed floor loads.

  • Standard
    2 pages
    English language
    sale 15% off
  • Standard
    3 pages
    French language
    sale 15% off
  • Standard
    3 pages
    French language
    sale 15% off